Universal Tilt ‘N Plug™ Interconnect Box
USER'S GUIDE
Download from Www.Somanuals.com. All Manuals Search And Download.
ACCESSORIES
cause serious injury because of the sharp
edges inside of the TNP500/502.
PRECAUTIONS / SAFETY WARNINGS
1
Please read this manual carefully before using your
TNP500/502 Interconnect Box. Keep this manual
handy for future reference. These safety instructions
are to ensure the long life of your TNP500/502 and to
prevent fire and shock hazard. Please read them
carefully and heed all warnings.
·
·
Do not place heavy objects on top of the
TNP500/502. Do not use excessive force to
push down on the top of the unit.
To turn off the main power, disconnect the
power cord, which powers the power socket
on the TNP500/502 pop up panel. The
power outlet socket should be installed as
near to the equipment as possible, and
should be easily accessible.
1.1 GENERAL
·
Unauthorized personnel shall not open the
unit since there are high-voltage
components inside.
·
·
We recommend using wall outlets with a
Ground Fault Circuit Interrupter (GFCI) for
maximum protection.
·
Qualified ALTINEX service personnel, or
their authorized representatives must
perform all service.
Install all cables according to the
instructions. Do not force or pull out any
cable or power cord that is attached to the
TNP500/502 Interconnect Box.
1.3 CLEANING
Surfaces should be cleaned with a dry cloth.
·
Never use strong detergents or solvents,
such as alcohol or thinner. Do not use a wet
cloth or water to clean the unit.
1.4 FCC / CE NOTICE
·
·
This device complies with part 15 of the
1.2 INSTALLATION
FCC Rules. Operation is subject to the
following two conditions: (1) This device
may not cause harmful interference, and (2)
this device must accept any interference
received, including interference that may
cause undesired operation.
·
For best results, place the TNP500/502
Interconnect Box in a dry area away from
dust and moisture.
·
To prevent fire or shock, do not expose this
unit to rain or moisture. Do not place the
TNP500/502 Interconnect Box in direct
sunlight, near heaters or heat radiating
appliances, or near any liquid. Exposure to
direct sunlight, smoke, or steam can harm
internal components.
This equipment has been tested and found
to comply with the limits for a Class A digital
device, pursuant to Part 15 of the FCC
Rules. These limits are designed to provide
reasonable protection against harmful
interference when the equipment is operated
·
·
Handle the TNP500/502 Interconnect Box
carefully. Dropping or jarring can damage
internal components.
in
a
commercial environment. This
equipment generates, uses, and can radiate
radio frequency energy and, if not installed
and used in accordance with the instruction
manual, may cause harmful interference to
radio communications. Operation of this
Never place fingers inside the opening on
each side of the unit. This action could
2
Download from Www.Somanuals.com. All Manuals Search And Download.
ACCESSORIES
equipment in a residential area is likely to
cause harmful interference in which case
the user will be required to correct the
interference at his own expense.
video (RCA), S-Video (4-pin mini-DIN), audio (2-
RCAs), computer audio (3.5 mm), modem (RJ11),
and network (RJ45) input connectors. All connectors
have 6 foot cables attached that feed through to the
bottom of the unit. The connectors and their labels
may be customized for a fee.
·
Any changes or modifications to the unit not
expressly approved by ALTINEX, Inc. could
void the user’s authority to operate the
equipment.
TECHNICAL SPECIFICATIONS
3
FEATURES/
DESCRIPTION
TNP502
ABOUT YOUR TNP500/502
2
GENERAL
The TNP500 designed for installation into a table in a
presentation or boardroom, the Tilt `N Plug™
Configurable Tabletop Interconnect Box provides
access to multi-media input connections when
needed, and hides them when not needed. This unit
can be configured with a wide variety of data or A/V
connectors before shipment from ALTINEX.
Using a tilting angular construction with pneumatic lift
assist and a mechanical latching mechanism, the
TNP500 can either "tilt up" into a raised position to
provide access to input plates, or it can be lowered
flush into the table when not in use. The unit is
opened and closed by pressing down on the top
panel.
Front Panel
Standard
Configuration
Connectors
Available
location
Faceplate
Up to 3 plates
Up to 6 plates
2 outlet per plate
1 15-pin HD-F
Power
Computer Video
Composite Video
Audio, left, right
1 Yellow RCA-F Up to 6 plates
1 Black, 1 Red
RCA-F
1 3.5 mm stereo
female plug
1 RJ-11 F (6-
position)
Up to 6 plates
Audio
Up to 6 plates
Up to 6 plates
Telephone
Network
Control
1 RJ-45-F (8-
position)
Up to 6 plates
Up to 6 plates
Note that, while the TNP500 is similar in many ways
to its predecessor (TNP100), it actually performs the
lifting function internally, and does not require the user
to lift the faceplate up. Only light pressure is required
to unlatch the top to open it, and slightly more
pressure to push the lid down and close the unit.
1 DB-9 F
Table 1. TNP502 General
MECHANICAL
Width (inches)
Height (closed)
Height (opened)
Depth (inches)
Finish
T° Operating
T° Maximum
Humidity
TNP500/502
6.03in (153mm)
4.79in (122mm)
8.05in (205mm)
7.56in (192mm)
Flat Black
The TNP500 provides six Sectional Plate slots on the
exposed faceplate, servicing one side of a table.
Signals are passed through the unit to the underside
of the table. A variety of sectional plate connector
configurations are available to populate the slots - see
Sectional Plate Accessories for a list of available
options. All Sectional Plates must be ordered
separately.
10°C-45°C
60°C
90% non-condensing
Table 2. TNP500/502 Mechanical
The TNP502 is a "package" of parts that covers the
basic needs of many Tilt ‘N Plug users. When this
item is ordered, it ships as a completely assembled
product made up of: one TNP500 and a SP3500SC
Sectional Plate, with input labels already engraved
The SP3500SC includes the following connectors:
two standard U.S. power receptacles, computer video
(15-pin HD), COM Port/RS-232 (9-pin D), composite
ELECTRICAL
Power
Power Rating (pass through
connector)
TNP502
90-140 VAC, 5Amps
Max
Table 3. TNP502 Electrical
3
Download from Www.Somanuals.com. All Manuals Search And Download.
ACCESSORIES
TNP500/502 DIMENSIONS
4
Detailed dimensions, tabletop cutout templates and CAD drawings are
available on the ALTINEX website at www.altinex.com
4
Download from Www.Somanuals.com. All Manuals Search And Download.
ACCESSORIES
Available Plates
Many different plates can be installed on TNP500. In addition to standard plates, any custom plates can be made
using blank plates available. Additional description and part numbering is available on Altinex web site
5
Download from Www.Somanuals.com. All Manuals Search And Download.
ACCESSORIES
Final Installation view of TNP 502.
Sample configiration with modules installed
6
Download from Www.Somanuals.com. All Manuals Search And Download.
ACCESSORIES
DESCRIPTION
5 4: Final Installation view of TNP 502
APPLICATION DIAGRAM
6
7
Download from Www.Somanuals.com. All Manuals Search And Download.
ACCESSORIES
MOUNTING DIAGRAM
7
Table top
Support
bracket
Support
bracket
Table securing
screw
Table securing
screw
INSTALLATION
88
Step 4 Secure the cables by using the provided
cable clamp. Pass the power cord from the
bottom of the housing and attach it to the
table using the cable clamp supplied with
the TNP500/502 unit. Do not keep the cord
too tight or too loose.
Step 1. Cut an opening into the table’s surface.
Refer to diagram on Altinex web site
requirement s.
for
table
cutout
Note: The table can be 3 inches or thinner
in thickness. Always confirm dimensions
before cutting to insure that specifications
have not changed.
Step5 Connect the appropriate cables with the
correct input connectors. There are two
RCA audio connectors on the front panel of
the TNP500/502. The black connector is
known as audio left, whereas the red
connector is called audio right. There is
also an RCA video connector, which is
yellow in color. The network connection is
red. In addition, the telephone or data
connection is gray.
Step 2. Insert the TNP500/502 into the opening in
the table.
Step 3. Place the support brackets under the table
and place them between the support mount
grooves on the side of the TNP500/502
unit. Attach the brackets to the groove at
the desired height and secure them to the
bottom of the table using the 6-32 screw.
There are two support brackets, one for
each side of the unit.
8
Download from Www.Somanuals.com. All Manuals Search And Download.
ACCESSORIES
Step6 Once you have applied power and
connected the proper cables on the bottom
of the unit, you may raise the unit. To raise
the TNP500/502 into position lift the top by
pulling upward at the notch in the top plate.
FREQUENTLY ASKED QUESTIONS (FAQ)
No: Question Answer
Why are the VGA Female cables are more
9
1
connectors
female on both
ends of the
cables?
reliable.
Step 7. To lower the unit, push on the top of the
TNP500 until it fits into place.
2
3
4
5
Why is there a
DB-9 connector? compatible with RS-232
serial communication.
What happens if The unit will not stay
the spring
breaks?
The DB-9 connector is
For more information, please refer to the FAQ
section or the Troubleshooting Guide.
open.
What do I do if
Replace the gas spring.
the TNP500/502 Call ALTINEX for service
information.
How much room The unit is 4.5 inches
is taken up on deep maximum below
the underside of the table; to this
the table? dimension add about 2.5
won’t stay open?
inches for cable
clearance.
6
7
What if my table Then the area under the
is thicker than 3
inches?
table near the
TNP500/502 must be
reduced to 3 inches of
thickness.
Are cables
CONSIDER USING
available for
connecting a
PC/laptop to the
TNP500/502
available?
MS8126CA (3FT) OR
MS8156CA (6FT) FOR
VGA CONNECTION.
8
Does ALTINEX
honor any
Anything modified by non-
ALTINEX personnel is not
warranty on field covered by warranty.
modifications?
9
Download from Www.Somanuals.com. All Manuals Search And Download.
ACCESSORIES
CABLES AND ACCESSORIES
10
TROUBLESHOOTING GUIDE
11
Model No.
Description
VGA MALE TO MALE (HD-15) HIGH
RESOLUTION CABLE
The supplied TNP500/502 unit was carefully tested
and no problems were detected; however, we
would like to offer the following suggestions:
CB37xxMR xx = available length of 3ft, 6ft, 15ft,
25ft, 50ft, 75ft, 100ft, 150ft
·
If there is no power, check the integrity of the
power cord. Make sure that no cable or power
cord is damaged or pinched. If there has been
damage, then do not use the TNP500 unit.
Immediately contact the ALTINEX Customer
Service Department to have the unit repaired.
VGA MALE TO FEMALE (HD-15)
HIGH RESOLUTION CABLE
CB39xxMR xx = available length of 3ft, 6ft, 15ft,
25ft, 50ft, 75ft, 100ft, 150ft, 200ft, 250ft
SUPER HIGH RESOLUTION
·
·
Please make sure that the highest quality video,
audio, network, and telephone cables or
connectors are used.
PLENUM-FLEX MULTI- CHANNEL
COAX CABLE
VGA MALE TO VGA MALE (HD-15)
CB5000PL- xxx = available length of 3ft, 6ft, 15ft,
If unit does not lift over a period of time please
check the wear and tear on gas spring. If
replacement of gas spring is required contact
ALTINEX.
25ft, 50ft, 75ft, 100ft, 150ft, 200ft, 250ft
SUPER HIGH RESOLUTION
PLENUM-FLEX MULTI- CHANNEL
COAX CABLE
5VMxxxVM
VGA MALE TO VGA FEMALE (HD-
15)
ALTINEX POLICY
12
CB5000PL- xxx = available length of 3ft, 6ft, 15ft,
25ft, 50ft, 75ft, 100ft, 150ft, 200ft, 250ft
12.0 LIMITED WARRANTY / RETURN POLICY
5VMxxxVF
Please
see
the
Altinex
website
at
www.altinex.com for details on warranty and