Altinex Switch TNP500 502 User Manual

ACCESSORIES  
MANUAL PART NUMBER: 400-0091-005  
TNP500/502  
Universal Tilt ‘N Plug™ Interconnect Box  
USER'S GUIDE  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ACCESSORIES  
cause serious injury because of the sharp  
edges inside of the TNP500/502.  
PRECAUTIONS / SAFETY WARNINGS  
1
Please read this manual carefully before using your  
TNP500/502 Interconnect Box. Keep this manual  
handy for future reference. These safety instructions  
are to ensure the long life of your TNP500/502 and to  
prevent fire and shock hazard. Please read them  
carefully and heed all warnings.  
·
·
Do not place heavy objects on top of the  
TNP500/502. Do not use excessive force to  
push down on the top of the unit.  
To turn off the main power, disconnect the  
power cord, which powers the power socket  
on the TNP500/502 pop up panel. The  
power outlet socket should be installed as  
near to the equipment as possible, and  
should be easily accessible.  
1.1 GENERAL  
·
Unauthorized personnel shall not open the  
unit since there are high-voltage  
components inside.  
·
·
We recommend using wall outlets with a  
Ground Fault Circuit Interrupter (GFCI) for  
maximum protection.  
·
Qualified ALTINEX service personnel, or  
their authorized representatives must  
perform all service.  
Install all cables according to the  
instructions. Do not force or pull out any  
cable or power cord that is attached to the  
TNP500/502 Interconnect Box.  
1.3 CLEANING  
Surfaces should be cleaned with a dry cloth.  
·
Never use strong detergents or solvents,  
such as alcohol or thinner. Do not use a wet  
cloth or water to clean the unit.  
1.4 FCC / CE NOTICE  
·
·
This device complies with part 15 of the  
1.2 INSTALLATION  
FCC Rules. Operation is subject to the  
following two conditions: (1) This device  
may not cause harmful interference, and (2)  
this device must accept any interference  
received, including interference that may  
cause undesired operation.  
·
For best results, place the TNP500/502  
Interconnect Box in a dry area away from  
dust and moisture.  
·
To prevent fire or shock, do not expose this  
unit to rain or moisture. Do not place the  
TNP500/502 Interconnect Box in direct  
sunlight, near heaters or heat radiating  
appliances, or near any liquid. Exposure to  
direct sunlight, smoke, or steam can harm  
internal components.  
This equipment has been tested and found  
to comply with the limits for a Class A digital  
device, pursuant to Part 15 of the FCC  
Rules. These limits are designed to provide  
reasonable protection against harmful  
interference when the equipment is operated  
·
·
Handle the TNP500/502 Interconnect Box  
carefully. Dropping or jarring can damage  
internal components.  
in  
a
commercial environment. This  
equipment generates, uses, and can radiate  
radio frequency energy and, if not installed  
and used in accordance with the instruction  
manual, may cause harmful interference to  
radio communications. Operation of this  
Never place fingers inside the opening on  
each side of the unit. This action could  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
ACCESSORIES  
equipment in a residential area is likely to  
cause harmful interference in which case  
the user will be required to correct the  
interference at his own expense.  
video (RCA), S-Video (4-pin mini-DIN), audio (2-  
RCAs), computer audio (3.5 mm), modem (RJ11),  
and network (RJ45) input connectors. All connectors  
have 6 foot cables attached that feed through to the  
bottom of the unit. The connectors and their labels  
may be customized for a fee.  
·
Any changes or modifications to the unit not  
expressly approved by ALTINEX, Inc. could  
void the user’s authority to operate the  
equipment.  
TECHNICAL SPECIFICATIONS  
3
FEATURES/  
DESCRIPTION  
TNP502  
ABOUT YOUR TNP500/502  
2
GENERAL  
The TNP500 designed for installation into a table in a  
presentation or boardroom, the Tilt `N Plug™  
Configurable Tabletop Interconnect Box provides  
access to multi-media input connections when  
needed, and hides them when not needed. This unit  
can be configured with a wide variety of data or A/V  
connectors before shipment from ALTINEX.  
Using a tilting angular construction with pneumatic lift  
assist and a mechanical latching mechanism, the  
TNP500 can either "tilt up" into a raised position to  
provide access to input plates, or it can be lowered  
flush into the table when not in use. The unit is  
opened and closed by pressing down on the top  
panel.  
Front Panel  
Standard  
Configuration  
Connectors  
Available  
location  
Faceplate  
Up to 3 plates  
Up to 6 plates  
2 outlet per plate  
1 15-pin HD-F  
Power  
Computer Video  
Composite Video  
Audio, left, right  
1 Yellow RCA-F Up to 6 plates  
1 Black, 1 Red  
RCA-F  
1 3.5 mm stereo  
female plug  
1 RJ-11 F (6-  
position)  
Up to 6 plates  
Audio  
Up to 6 plates  
Up to 6 plates  
Telephone  
Network  
Control  
1 RJ-45-F (8-  
position)  
Up to 6 plates  
Up to 6 plates  
Note that, while the TNP500 is similar in many ways  
to its predecessor (TNP100), it actually performs the  
lifting function internally, and does not require the user  
to lift the faceplate up. Only light pressure is required  
to unlatch the top to open it, and slightly more  
pressure to push the lid down and close the unit.  
1 DB-9 F  
Table 1. TNP502 General  
MECHANICAL  
Width (inches)  
Height (closed)  
Height (opened)  
Depth (inches)  
Finish  
T° Operating  
T° Maximum  
Humidity  
TNP500/502  
6.03in (153mm)  
4.79in (122mm)  
8.05in (205mm)  
7.56in (192mm)  
Flat Black  
The TNP500 provides six Sectional Plate slots on the  
exposed faceplate, servicing one side of a table.  
Signals are passed through the unit to the underside  
of the table. A variety of sectional plate connector  
configurations are available to populate the slots - see  
Sectional Plate Accessories for a list of available  
options. All Sectional Plates must be ordered  
separately.  
10°C-45°C  
60°C  
90% non-condensing  
Table 2. TNP500/502 Mechanical  
The TNP502 is a "package" of parts that covers the  
basic needs of many Tilt ‘N Plug users. When this  
item is ordered, it ships as a completely assembled  
product made up of: one TNP500 and a SP3500SC  
Sectional Plate, with input labels already engraved  
The SP3500SC includes the following connectors:  
two standard U.S. power receptacles, computer video  
(15-pin HD), COM Port/RS-232 (9-pin D), composite  
ELECTRICAL  
Power  
Power Rating (pass through  
connector)  
TNP502  
90-140 VAC, 5Amps  
Max  
Table 3. TNP502 Electrical  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
ACCESSORIES  
TNP500/502 DIMENSIONS  
4
Detailed dimensions, tabletop cutout templates and CAD drawings are  
available on the ALTINEX website at www.altinex.com  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
ACCESSORIES  
Available Plates  
Many different plates can be installed on TNP500. In addition to standard plates, any custom plates can be made  
using blank plates available. Additional description and part numbering is available on Altinex web site  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
ACCESSORIES  
Final Installation view of TNP 502.  
Sample configiration with modules installed  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
ACCESSORIES  
DESCRIPTION  
5 4: Final Installation view of TNP 502  
APPLICATION DIAGRAM  
6
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
ACCESSORIES  
MOUNTING DIAGRAM  
7
Table top  
Support  
bracket  
Support  
bracket  
Table securing  
screw  
Table securing  
screw  
INSTALLATION  
88  
Step 4 Secure the cables by using the provided  
cable clamp. Pass the power cord from the  
bottom of the housing and attach it to the  
table using the cable clamp supplied with  
the TNP500/502 unit. Do not keep the cord  
too tight or too loose.  
Step 1. Cut an opening into the table’s surface.  
Refer to diagram on Altinex web site  
requirement s.  
for  
table  
cutout  
Note: The table can be 3 inches or thinner  
in thickness. Always confirm dimensions  
before cutting to insure that specifications  
have not changed.  
Step5 Connect the appropriate cables with the  
correct input connectors. There are two  
RCA audio connectors on the front panel of  
the TNP500/502. The black connector is  
known as audio left, whereas the red  
connector is called audio right. There is  
also an RCA video connector, which is  
yellow in color. The network connection is  
red. In addition, the telephone or data  
connection is gray.  
Step 2. Insert the TNP500/502 into the opening in  
the table.  
Step 3. Place the support brackets under the table  
and place them between the support mount  
grooves on the side of the TNP500/502  
unit. Attach the brackets to the groove at  
the desired height and secure them to the  
bottom of the table using the 6-32 screw.  
There are two support brackets, one for  
each side of the unit.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
ACCESSORIES  
Step6 Once you have applied power and  
connected the proper cables on the bottom  
of the unit, you may raise the unit. To raise  
the TNP500/502 into position lift the top by  
pulling upward at the notch in the top plate.  
FREQUENTLY ASKED QUESTIONS (FAQ)  
No: Question Answer  
Why are the VGA Female cables are more  
9
1
connectors  
female on both  
ends of the  
cables?  
reliable.  
Step 7. To lower the unit, push on the top of the  
TNP500 until it fits into place.  
2
3
4
5
Why is there a  
DB-9 connector? compatible with RS-232  
serial communication.  
What happens if The unit will not stay  
the spring  
breaks?  
The DB-9 connector is  
For more information, please refer to the FAQ  
section or the Troubleshooting Guide.  
open.  
What do I do if  
Replace the gas spring.  
the TNP500/502 Call ALTINEX for service  
information.  
How much room The unit is 4.5 inches  
is taken up on deep maximum below  
the underside of the table; to this  
the table? dimension add about 2.5  
won’t stay open?  
inches for cable  
clearance.  
6
7
What if my table Then the area under the  
is thicker than 3  
inches?  
table near the  
TNP500/502 must be  
reduced to 3 inches of  
thickness.  
Are cables  
CONSIDER USING  
available for  
connecting a  
PC/laptop to the  
TNP500/502  
available?  
MS8126CA (3FT) OR  
MS8156CA (6FT) FOR  
VGA CONNECTION.  
8
Does ALTINEX  
honor any  
Anything modified by non-  
ALTINEX personnel is not  
warranty on field covered by warranty.  
modifications?  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
ACCESSORIES  
CABLES AND ACCESSORIES  
10  
TROUBLESHOOTING GUIDE  
11  
Model No.  
Description  
VGA MALE TO MALE (HD-15) HIGH  
RESOLUTION CABLE  
The supplied TNP500/502 unit was carefully tested  
and no problems were detected; however, we  
would like to offer the following suggestions:  
CB37xxMR xx = available length of 3ft, 6ft, 15ft,  
25ft, 50ft, 75ft, 100ft, 150ft  
·
If there is no power, check the integrity of the  
power cord. Make sure that no cable or power  
cord is damaged or pinched. If there has been  
damage, then do not use the TNP500 unit.  
Immediately contact the ALTINEX Customer  
Service Department to have the unit repaired.  
VGA MALE TO FEMALE (HD-15)  
HIGH RESOLUTION CABLE  
CB39xxMR xx = available length of 3ft, 6ft, 15ft,  
25ft, 50ft, 75ft, 100ft, 150ft, 200ft, 250ft  
SUPER HIGH RESOLUTION  
·
·
Please make sure that the highest quality video,  
audio, network, and telephone cables or  
connectors are used.  
PLENUM-FLEX MULTI- CHANNEL  
COAX CABLE  
VGA MALE TO VGA MALE (HD-15)  
CB5000PL- xxx = available length of 3ft, 6ft, 15ft,  
If unit does not lift over a period of time please  
check the wear and tear on gas spring. If  
replacement of gas spring is required contact  
ALTINEX.  
25ft, 50ft, 75ft, 100ft, 150ft, 200ft, 250ft  
SUPER HIGH RESOLUTION  
PLENUM-FLEX MULTI- CHANNEL  
COAX CABLE  
5VMxxxVM  
VGA MALE TO VGA FEMALE (HD-  
15)  
ALTINEX POLICY  
12  
CB5000PL- xxx = available length of 3ft, 6ft, 15ft,  
25ft, 50ft, 75ft, 100ft, 150ft, 200ft, 250ft  
12.0 LIMITED WARRANTY / RETURN POLICY  
5VMxxxVF  
Please  
see  
the  
Altinex  
website  
at  
www.altinex.com for details on warranty and  
return policy.  
12.1 CONTACT INFORMATION  
ALTINEX, INC.  
592 Apollo Street  
Brea, CA 92821 USA  
TEL: 714-990-2300  
TOLL FREE: 1-800-ALTINEX  
FAX: 714-990-3303  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  

3Comr TCM 465V 459V 36 User Manual
Aastra Telecom Telephone M6320 User Manual
Air King Vacuum Cleaner AKCVQZ99 User Manual
AllerAir Air Cleaner 5000 D MCS User Manual
ATN Binoculars ATN PS14 User Manual
ATN Binoculars MK 6600 User Manual
Axis Communications Home Security System Q7401 User Manual
Barco Crib Toy w18 User Manual
BC Speakers Portable Speaker WG800 User Manual
Beko Clothes Dryer DRVT 61 W User Manual