Altinex Switch MT107 303 User Manual

MULTITASKER®  
MANUAL PART NUMBER: 400-0372-005  
MT107-303  
8-OUT, TWISTED PAIR, SINGLE CHANNEL  
OUTPUT CARD FOR MATRIX SWITCHER  
USER’S GUIDE  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MULTITASKER  
PRECAUTIONS / SAFETY WARNINGS  
1
·
This equipment has been tested and found to  
comply with the limits for a Class A digital device  
pursuant to Part 15 of the FCC Rules. These  
limits are designed to provide reasonable  
protection against harmful interference when the  
Please read this manual carefully before using your  
MT107-303. Keep this manual handy for future  
reference. These safety instructions are to ensure  
the long life of your MT107-303 and to prevent fire  
and shock hazards. Please read them carefully and  
heed all warnings.  
equipment is operated in  
a
commercial  
environment. This equipment generates, uses,  
and can radiate radio frequency energy and, if  
not installed and used in accordance with the  
instructions found herein, may cause harmful  
interference to radio communications. Operation  
of this equipment in a residential area is likely to  
cause harmful interference in which case the  
user will be required to correct the interference  
at his own expense.  
1.1 GENERAL  
·
Qualified ALTINEX service personnel or their  
authorized representatives must perform all  
service.  
1.2 INSTALLATION  
·
To prevent fire or shock, do not expose this unit  
to water or moisture. Do not place the  
MT107-303 in direct sunlight, near heaters, or  
heat-radiating appliances, or near any liquid.  
Exposure to direct sunlight, smoke, or steam can  
harm internal components.  
·
Any changes or modifications to the unit not  
expressly approved by ALTINEX, Inc. could void  
the user’s authority to operate the equipment.  
·
·
·
Handle the MT107-303 carefully. Dropping or  
jarring can damage the card.  
Do not pull any cables that are attached to the  
MT107-303.  
Insert the card carefully into the slots of the  
MultiTasker without bending any edges.  
1.3 CLEANING  
·
Clean only the connector area with a dry cloth.  
Never use strong detergents or solvents such as  
alcohol or thinner. Do not use a wet cloth or  
water to clean the card. Do not clean or touch  
any component or PCB.  
1.4 FCC NOTICE  
·
This device complies with Part 15 of the FCC  
Rules. Operation is subject to the following two  
conditions: (1) This device may not cause  
harmful interference, and (2) this device must  
accept any interference received, including  
interference that may cause undesired  
operation.  
400-0372-005  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
MULTITASKER  
ABOUT YOUR MT107-303  
2
TECHNICAL SPECIFICATIONS  
3
Specifications are subject to change.  
See www.altinex.com for up-to-date information.  
MT107-303  
8-Out, Twisted Pair, Single Channel  
FEATURES/  
MT107-303  
The MT107-303 is an 8 Output expansion card for  
use with the MT107-104 64X64 Matrix Engine. The  
MT107-303 outputs are single channel differential  
outputs for use over long cable lengths. The  
Twisted Pair signals from the MT107-303 may be  
easily combined into a single CAT-5 cable using  
ALTINEX MS8704TP adapter cables. The CAT-5  
cable is then run to an ALTINEX Twisted Pair  
receiver such as the DA1931CT.  
DESCRIPTION  
GENERAL  
Input  
Twisted Pair  
Internal Box Header (1)  
RJ-45 female (8)  
Output Connectors  
Twisted Pair  
Compatibility  
ALTINEX Standard for  
Twisted Pair  
Signal Types  
Each MT107-303 connects to an output connector  
on the MT107-104 Matrix Engine. Up to 8  
MT107-303 cards may be connected to the engine  
and each card is connected with the engine via  
specially provided, high-bandwidth video cables.  
Video Signal  
Resolutions  
VGA through UXGA  
480p through 1080i  
VGA:  
640x480@60Hz  
900 ft (274 m)  
Recommended Max.  
Cable Lengths  
Note: Measurements  
made using ALTINEX  
low-skew cable,  
As part of the MT107-104 Matrix Engine, the  
MT107-303 has special built-in features. Signal  
detection circuitry allows the user to determine the  
presence of an output signal on any channel.  
XGA: 1024x768@60Hz  
700 ft (213 m)  
SXGA: 1280x1024@60Hz  
650 ft (198 m)  
CB3150PV.  
Output signals are driven by high-speed,  
high-bandwidth differential amplifiers.  
UXGA: 1600x1200@60Hz  
600 ft (183 m)  
ALTINEX’s software and hardware allow for the  
switching of any input to output combination and  
prevents illegal switching combinations that may  
damage components.  
Table 1. MT107-303 General  
MECHANICAL  
Enclosure Slots Required  
Weight  
MT107-303  
1
The latest generation of Twisted Pair devices uses  
an innovative, patented technology* developed by  
ALTINEX. The new signal processing technology  
allows transmitting and receiving fully equalized  
computer video signals, stereo, and audio signals  
over long distances.  
0.4 lb (0.18 kg)  
Black Anodized  
10°C-50°C  
Connector Panel  
T° Operating  
T° Maximum  
75°C  
Humidity  
90% non-condensing  
38,000 hrs  
* US Patent 7,065,190  
MTBF (calc.)  
Table 2. MT107-303 Mechanical  
400-0372-005  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
MULTITASKER  
ELECTRICAL  
Output  
MT107-303  
Video/Sync/Audio Signals  
ALTINEX Standard  
Twisted Pair  
Analog Signal Level  
Input  
1.5 Vp-p max.  
Bus from Matrix Engine  
0 dB gain  
Power Consumption (from enclosure)  
+6V  
0.225 A (1.3 W)  
-6V  
0.190 A (1.1 W)  
2.4 W max.  
Total Power  
Table 3. MT107-303 Electrical  
400-0372-005  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
MULTITASKER  
PRODUCT DESCRIPTION  
4
8 1TP OUTPUTS  
BOTTOM RETAINER SCREW  
400-0372-005  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
MULTITASKER  
APPLICATION DIAGRAMS  
DIAGRAM 1: TYPICAL SETUP  
5
MT107-303  
400-0372-005  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
MULTITASKER  
DIAGRAM 2: INTERNAL VIEW  
POWER  
IN1  
IN2  
IN3  
OUT1  
OUT2  
OUT3  
IN4  
OUT4  
INPUT  
TWISTED  
40-PIN  
IDC  
PAIR  
RJ-45  
IN5  
IN6  
IN7  
IN8  
OUT5  
OUT6  
OUT7  
OUT8  
SIGNAL  
DETECT  
400-0372-005  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
MULTITASKER  
INSTALLING YOUR MT107-303  
6
OPERATION  
7.1 RS-232 CONTROL  
The MT107-303  
7
Step 1. Turn off power to the MultiTasker  
enclosure and remove the input AC power  
cord.  
has  
many  
advanced  
remote-control capabilities as part of an  
MT107-104 Matrix Switcher. These capabilities  
are accessible through standard RS-232  
communication. The actual controlling can be  
Step 2. Locate the MT107-104 currently installed  
in the MultiTasker. Verify there is an  
empty slot in the enclosure for the new  
MT107-303 card.  
accomplished through  
a
computer control  
system or any other device capable of sending  
RS-232 commands.  
The MT107-303 must be installed directly  
to the right of the MT107-104 Matrix  
Engine. For example, if the engine is  
installed in slots 9 and 10, the first  
MT107-303 output card should be  
installed in slot 11, the second in slot 12,  
and so on.  
7.2 DESCRIPTION OF COMMANDS  
Please see the MT107-104 User's Guide for a  
full listing of commands available for the  
MT107-303 as part of a MultiTasker Matrix  
Switcher.  
Step 3. Route the ribbon cables through the notch  
in the add-on boards and connect to the  
MT107-104 base assembly using the  
special high-bandwidth cables provided  
with the engine. Make sure the cable  
connector is secured in the socket of the  
output connector card.  
TROUBLESHOOTING GUIDE  
8
We have carefully tested and found no problems in  
the supplied MT107-303. However, we would like to  
offer suggestions for the following:  
8.1 NO DISPLAY  
Cause 1: The source has a problem.  
Step 4. Attach the opposite end of the ribbon  
cable to the card and carefully slide the  
MT107-303 into the empty slot in the  
MultiTasker enclosure.  
Solution: Check the source and make sure  
that there is a signal present and all  
source connections are correct. If  
the source is working and there is  
still no display, see Cause 2.  
Step 5. Secure the card by tightening the retainer  
screws at the top and bottom.  
Cause 2: The input signal is not detected.  
Step 6. Connect the output of the MT107-303 to  
the input of a Twisted Pair receiver using  
ALTINEX cable part number MS8704TP.  
Solution 1: In AVSnap®, or other control  
software, send the [SDI] command.  
This command is detailed in the  
MT107-104's User Guide. Verify a  
signal is detected for the output  
number in question. If a signal is not  
detected, see Solution 2.  
Step 7. Restore AC power to the enclosure.  
Step 8. The MT107-303 is now ready for  
operation.  
Solution 2: Verify the MT107-303 is connected  
to the MT107-104 and that the cable  
is in good condition. If a signal is  
detected, see Cause 3. If there is no  
signal  
detected,  
please  
call  
ALTINEX at (714) 990-2300.  
400-0372-005  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
MULTITASKER  
Cause 3: The path is not selected.  
ALTINEX POLICIES  
9
Solution: Make sure the input to output path is  
9.1 LIMITED WARRANTY/RETURN POLICIES  
correctly selected.  
Please see the ALTINEX website at  
www.altinex.com for details on warranty and  
return policies.  
For example, Input 2 is connected to  
Output 1 in the Matrix Engine status.  
Physically, the source signal should  
be connected to Input 2 and the  
display cable should be connected  
to Output 1. See RS-232 accessible  
commands in Section 7 of the  
9.2 CONTACT INFORMATION  
ALTINEX, Inc.  
592 Apollo Street  
MT107-104 User’s  
command details.  
Guide for  
Brea, CA 92821 USA  
TEL: 714 990-2300  
If no display is present, see  
Cause 4.  
TOLL FREE: 1-800-ALTINEX  
Cause 4: Cable connections are incorrect.  
Solution: Make sure that cables are properly  
connected. Also, make sure that the  
continuity and wiring are good. If  
there is still no display present, see  
Cause 5.  
Cause 5: The display has a problem.  
Solution: Make sure the display is powered  
and is turned on. If there is still no  
display, please call ALTINEX at  
(714) 990-2300.  
400-0372-005  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  

Abocom Switch LF560 User Manual
Acclaim Lighting Work Light RGBX DRUM HIP User Manual
AEG Washer 62600 User Manual
Agilent Technologies Water Dispenser E4403B User Manual
Alpine Car Stereo System CVA 1003 User Manual
Alpine CD Player CDE HD149BT User Manual
Alps Electric Hot Tub Ciara XLS User Manual
Audiovox Automobile Alarm PRO 2032 User Manual
Avenview Switch SPLIT DVI 2 User Manual
Axor Plumbing Product 42235000 User Manual