DISTRIBUTION AMPLIFIERS
MANUAL PART NUMBER: 400-0078-003
PRODUCT REVISION: 1
DAA0106-V0A2
1-IN, 6-OUT AUDIO
DISTRIBUTION AMPLIFIER
USER’S GUIDE
Download from Www.Somanuals.com. All Manuals Search And Download.
DISTRIBUTION AMPLIFIERS
· Handle the
DAA0106-V0A2
Amplifier carefully because dropping or jarring
can damage internal components.
Distribution
PRECAUTIONS / SAFETY WARNINGS
1
Please read this manual carefully before using your
DAA0106-V0A2 Distribution Amplifier. Keep this
manual handy for future reference. These safety
instructions are to ensure the long life of your
DAA0106-V0A2 and to prevent fire and shock
hazard. Please read them carefully and heed all
warnings.
· Do not place heavy objects on top of the
DAA0106-V0A2. If the is to be mounted to a
table or wall, use only Altinex made mounting
accessories, such as rack mount shelf
(DA1293FC, DA1294FC) and cables for
optimum setup.
· To turn off the main power, be sure to remove
the cord from the power outlet. The power
outlet socket should be installed as close to the
equipment as possible, and should be easily
accessible.
1.1 GENERAL
· Unauthorized personnel shall not open the unit
since there are high-voltage components
inside.
· Qualified Altinex service personnel, or their
authorized representatives must perform all
service.
· Do not pull the power cord or any cable that is
attached to the DAA0106-V0A2 Distribution
Amplifier.
· If the DAA0106-V0A2 Distribution Amplifier is
not used for an extended period, disconnect the
power cord from the power outlet.
1.2 SAFETY GUIDELINES FOR THE RACK-
MOUNTING OF THE DAA0106-V0A2
· Maximum operating ambient temperature is 35
1.4 CLEANING
(degrees C).
· Never restrict the air flow through the devices’
· Unplug the DAA0106-V0A2 power cord before
cleaning. Clean surfaces with a dry cloth. Never
use strong detergents or solvents, such as
alcohol or thinner. Do not use a wet cloth or
water to clean the unit.
fan or vents.
· When installing equipment into
a
rack,
distribute the units evenly. Otherwise,
hazardous conditions may be created by an
uneven weight distribution.
1.5 FCC / CE NOTICE
· Connect the unit to a properly rated supply
· This device complies with part 15 of the FCC
Rules. Operation is subject to the following two
conditions: (1) This device may not cause
harmful interference, and (2) this device must
accept any interference received, including
interference that may cause undesired
operation.
circuit.
· Reliable Earthing (Grounding) of Rack-Mounted
Equipment should be maintained.
1.3 INSTALLATION
· For best results, place the DAA0106-V0A2
Distribution Amplifier on a flat, leveled surface
in a dry area away from dust and moisture.
· This equipment has been tested and found to
comply with the limits for a Class A digital
device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide
· To prevent fire or shock, do not expose this unit
to rain or moisture. Do not place the
DAA0106-V0A2 Distribution Amplifier in direct
sunlight, near heaters or heat radiating
appliances, or near any liquid. Exposure to
direct sunlight, smoke, or steam can harm
internal components.
reasonable
protection
against
harmful
interference when the equipment is operated in
a commercial environment. This equipment
generates, uses, and can radiate radio
frequency energy and, if not installed and used
in accordance with the instruction manual, may
2
Download from Www.Somanuals.com. All Manuals Search And Download.
DISTRIBUTION AMPLIFIERS
cause
harmful
interference
to
radio
MECHANICAL
Audio
communications. Operation of this equipment
in a residential area is likely to cause harmful
interference in which case the user will be
required to correct the interference at his own
expense.
Material
Finish
Top Panel
0.1” Al
Gray
Lexan
Height (inches)
Width (inches)
Depth (inches)
Weight (pounds)
Ship Weight (pounds)
T° Operating
T° Maximum
Humidity
1.75in (44mm)
8.50in (216mm)
4.93in (125mm)
2.0lbs. (0.91kg)
4.0lbs. (1.81kg)
10°C-35°C
· Any changes or modifications to the unit not
expressly approved by Altinex, Inc. could void
the user’s authority to operate the equipment.
50°C
ABOUT YOUR DISTRIBUTION AMPLIFIER 2
50% non-condensing
MTBF (calculations)
40,000 hrs
The DAA0106-V0A2 is a product of exceptional
quality and design, which includes stereo audio
amplifiers.
Table 2. DAA0106-V0A2 Mechanical
ELECTRICAL
Input Signals
Level
Audio
The audio amplifier is designed to provide six
buffered and amplified outputs for both left and
right channels. The input signals are isolated to
prevent ground loops. The input termination is
switch selectable to either be 600 Ohms or high
impedance.
10 V p-p max
600 Ohms or high
impedance
Differential input
isolated from GND
Impedance
Type
Output Signals
Level
Impedance
Type
The DAA0106-V0A2 Distribution Amplifier is a
state-of-the-art product with a bandwidth of 10Hz to
20kHz for audio signals.
10V p-p
Low – drives 600 Ohms
Differential input
isolated from GND
0 dB unbalanced, +6dB
balanced
Gain
TECHNICAL SPECIFICATIONS
3
Frequency Compatibility
Typical Bandwidth
Power
FEATURES/DESCRIPTION
GENERAL
Audio
10Hz – 20kHz
1
No. of Inputs
Input Connector
Internal Power Supply
90-140V/
200-240V
10 watts max
One 3.5 mm 5-pin
Terminal Block
6
Six 3.5mm Terminal
Blocks
Power Consumption
No. of Outputs
Output Connector
Table 3. DAA0106-V0A2 Electrical
Stereo or Mono Audio
Compatibility
Table 1. DAA0106-V0A2 General
3
Download from Www.Somanuals.com. All Manuals Search And Download.
DISTRIBUTION AMPLIFIERS
DESCRIPTION OF DAA0106-V0A2
4
4
Download from Www.Somanuals.com. All Manuals Search And Download.
DISTRIBUTION AMPLIFIERS
APPLICATION DIAGRAM
5
5
Download from Www.Somanuals.com. All Manuals Search And Download.
DISTRIBUTION AMPLIFIERS
INSTALLING YOUR DISTRIBUTION
AMPLIFIER
OPERATION
7
6
The DAA0106-V0A2 will operate successfully as
long as cables are attached properly and other
technical specifications are followed.
Step 1. Connect the power cord to the unit and
plug it into the power outlet. The power
indicator LED on the front panel will light.
This indicates that the unit is operational.
7.1 TERMINATION SWITCH
The termination switch of the audio amplifier may
be set to 600 Ohms on the audio input if it is in the
ON position, and high impedance in the OFF
position.
Step 2. Connect the audio output of the source
(computer, VCR, etc.) to the input of the
DAA0106-V0A2 using high quality cables.
The LED on the front panel will turn
green. This indicates an input signal on
the input of the distribution amplifier.
Step 3. Connect the output channels of the
amplifier to the display devices, such as
monitors or projectors.
Step 4. Verify that the quality of the output signal
on all speakers is good. If the quality of
the output signal is less than perfect,
make sure that high quality cables are
used, and all connections are solid.
CONGRATULATIONS! YOU ARE DONE.
If you experience any problems, please call
1-800-258-4623 or 1-714-990-2300 for
international calls.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
DISTRIBUTION AMPLIFIERS
ACCESSORIES
Model No.
8
FREQUENTLY ASKED QUESTIONS
9
No: Question Answer
Description
1
What is a
Distribution
Amplifier?
A Distribution Amplifier is a
device that allows you to
connect a single signal
source to multiple display
devices, such as monitors
or projectors used in
TABLE MOUNT BRACKETS
1 U High, ½ Rack-Wide
1 U High, ½ Rack-Wide with 15-pin
HD connector plate
1 U High, ½ Rack-Wide with SNAP-
IN connectors
TM1271
TM1272
TM1273
TM1274
1 U High, ½ Rack-Wide with SNAP-
IN and power connectors
RACK MOUNTING BRACKETS
19” - 1U Rack Mount Shelf (for
tandem 2- Units)
19”- 1U Rack Mount Ears for
single unit
HIGH RESOLUTION MULTI-
CHANNEL COAX CABLE
length XX = 3, 6, 12, 25, 50, 75,
100, 150 feet
presentation applications.
When do I use In some cases, you need a
2
3
connection of an audio
source to as many as six
different audio amplifiers.
The DAA0106-V0A2 can
pass mono or stereo audio
signals.
the DAA0106-
V0A2?
DA1293FC
DA1294FC
Which signal
format can be
passed
through the
DAA0106-
V0A2?
4
What if I do
not use all of
the outputs?
All of the outputs are
4 BNC to 4 BNC
5 BNC to 5 BNC
SUPER HIGH RESOLUTION
MULTI-CHANNEL COAX CABLE
length XX = 3, 6, 12, 25, 50, 75,
100, 150 feet
CB41XXMR
CB42XXMR
completely independent,
and it is not necessary to
terminate unused outputs.
4 BNC to 4 BNC
5 BNC to 5 BNC
CB43XXMR
CB44XXMR
PLENUM-FLEX MULTI-CHANNEL
COAX CABLE
length XXX = 3, 6, 12, 25, 50, 75,
100, 150, 200, 250 feet
5 BNC to 5 BNC, high resolution
coax cable
5 BNC to 5 BNC, super high
resolution coax cable
CB5000PL-
5BM0XXX5BM
CB5100PL-
5BM0XXX5BM
POWER CABLES
Power cable for US
PC5301US
PS5302UK
PS5303AU
PS5304GR
Power cable for England
Power cable for Australia
Power cable for Germany
7
Download from Www.Somanuals.com. All Manuals Search And Download.
DISTRIBUTION AMPLIFIERS
If the product has been opened, the restocking
fees will apply. For the restocking fee amount,
please contact an Altinex Sales Representative.
TROUBLESHOOTING GUIDE
10
· Please make sure that the audio voltage level is
less than 10V p-p.
If the product is in your possession for more than
30 days, the restocking fees will also apply.
· Make sure to use the correct power cable with
the appropriate connector for the country in
which it is being used.
Altinex will not accept any returns on cables or
custom products.
· If a problem arises after continuous usage at
higher voltage, higher temperature, higher
humidity, or at other extreme environmental
conditions, please correct the problem.
If your product is in warranty and needs service,
contact the Altinex Sales Department for an RMA
(Return Material Authorization). Products returned
without an RMA number may experience a delay
in service.
ALTINEX POLICY
11
If your product is out of warranty and needs
service, contact the Altinex Sales Department for
an RMA (Return Material Authorization). Products
returned without an RMA number may experience
a delay in service. The service charges will be
quoted to you before the actual repairs are done.
11.1 LIMITED WARRANTY
Altinex warrants that its products and cables are
free from defects in materials under normal use
and service. This warranty is limited to repairing at
company’s factory any part or parts of the product,
which upon company’s examination shall disclose
to be, thus defective. Products shall be returned to
the company with transportation charges pre-paid
within 2 years (90 days for cables) from date of
shipment to the purchaser. The warranty is
expressly instead of all other warranties
expressed or implied. Altinex neither assumes nor
authorizes any other person to assume for it any
other liability in connection with the sale of the
products. This warranty shall not apply to any
product that has been repaired or altered outside
of company’s factory in any way so as, in its
judgment, to affect its stability or reliability, or that
has been subject to misuse, negligence or
accident.
11.3 CONTACT INFORMATION
Sales Department
Phone:
Fax:
714-990-2300
714-990-3303
Accounting Department
Phone:
Fax:
714-990-6088
714-990-5778
11.2 RETURN POLICY
It is very important to Altinex that you receive the
products that you have ordered and that this
product fulfills your need. In the unlikely event that
an Altinex product needs to be returned please
follow the policy below:
Altinex will accept product returns for a period of
30 days from authorized Altinex dealers. Products
should be returned in an unopened package.
8
Download from Www.Somanuals.com. All Manuals Search And Download.
|