DISTRIBUTION AMPLIFIERS
MANUAL PART NUMBER: 400-0007-003
PRODUCT REVISION: 1
DA1912SX
1-IN, 2-OUT RGBS
DISTRIBUTION AMPLIFIER
USER’S GUIDE
Download from Www.Somanuals.com. All Manuals Search And Download.
DISTRIBUTION AMPLIFIERS
mounted, to a table or wall, use only Altinex
PRECAUTIONS / SAFETY WARNINGS
1
made mounting accessories, such as mini
mount-brackets (DA1295FC) and cables for
optimum setup.
Please read this manual carefully before using your
DA1912SX Distribution Amplifier. Keep this manual
handy for future reference. These safety
instructions are to ensure the long life of your
DA1912SX and to prevent fire and shock hazard.
Please read them carefully and heed all warnings.
·
To turn off the main power, be sure to remove
the cord from power outlet. The power outlet
socket should be installed as near to the
equipment as possible, and should be easily
accessible.
1.1 GENERAL
·
Unauthorized personnel shall not open the unit
since there are high-voltage components
inside.
·
·
Do not pull power cord or any cable that is
attached to the DA1912SX Distribution
Amplifier.
·
Qualified Altinex service personnel, or their
authorized representatives must perform all
service.
If the DA1912SX Distribution Amplifier is not
used for an extended, disconnect the power
cord from the power outlet.
1.2 SAFETY GUIDELINES FOR THE RACK-
MOUNTING OF THE DA1912SX
1.4 CLEANING
Unplug the DA1912SX power cord before
·
·
·
·
Maximum operating ambient temperature is 35
(degrees C).
cleaning. Clean surfaces with a dry cloth.
Never use strong detergents or solvents such
as alcohol or thinner. Do not use a wet cloth or
water to clean the unit.
Never restrict the airflow through the device’s
fan or vents.
When installing equipment into a rack,
distribute the units evenly. Otherwise,
hazardous conditions may be created by an
uneven weight distribution.
1.5 FCC / CE NOTICE
·
·
This device complies with the part 15 of the
FCC Rules. Operation is subject to the
following two conditions: (1) This device may
not cause harmful interference, and (2) this
device must accept any interference received,
including interference that may cause
undesired operation.
·
Connect the unit to a properly rated supply
circuit.
·
Reliable Earthing (Grounding) of Rack-Mounted
Equipment should be maintained.
This equipment has been tested and found to
comply with the limits for a Class A digital
device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide
1.3 INSTALLATION
·
For best results, place the DA1912SX
Distribution Amplifier on a flat, level surface in
a dry area away from dust and moisture.
reasonable
protection
against
harmful
·
To prevent fire or shock, do not expose this
unit to rain or moisture. Do not place the
DA1912SX Distribution Amplifier in direct
sunlight, near heaters or heat radiating
appliances, or near any liquid. Exposure to
direct sunlight, smoke, or steam can harm
internal components.
interference when the equipment is operated
in a commercial environment. This equipment
generates, uses, and can radiate radio
frequency energy and, if not installed and used
in accordance with the instruction manual, may
cause
harmful
interference
to
radio
communications. Operation of this equipment
in a residential area is likely to cause harmful
interference in which case the user will be
required to correct the interference at his own
expense.
·
·
Handle the DA1912SX Distribution Amplifier
carefully. Dropping or jarring can damage
internal components.
Do not place heavy objects on top of the
DA1912SX. If the DA1912SX is to be
2
Download from Www.Somanuals.com. All Manuals Search And Download.
DISTRIBUTION AMPLIFIERS
·
Any changes or modifications to the unit not
expressly approved by Altinex, Inc. could void
the user’s authority to operate the equipment.
MECHANICAL
DA1912SX
Width (inches)
Height (inches)
Depth (inches)
Weight (pounds)
Ship Weight (pounds)
Material
4.56in (116mm)
3.50in (89mm)
0.94in (24mm)
0.6lbs (0.27kg)
2.0lbs (0.91kg)
0.1” Al
ABOUT YOUR DISTRIBUTION AMPLIFIER 2
The DA1912SX Distribution Amplifier is designed
to allow the connection of one high resolution
RGsB or RGBS source to up two scan rate
compatible monitors or projectors.
Finish
Top Panel
Gray
Lexan
T° Operating
T° Maximum
Humidity
10°C-35°C
50°C
Although designed to pass an RGBS signal format,
the DA1912SX can also pass RGsB, Component
Video (Y, R-Y, B-Y), S-Video (Y/C), and Composite
Video by using the appropriate channels. Video
sources must be passed through Red, Green,
and/or Blue channels. The sync channel is not
designed to pass video.
90% non-condensing
MTBF (calculations)
40,000 hrs
Table 2. DA1912SX Mechanical
ELECTRICAL
DA1912SX
Input Video Signal
Analog Signal
Impedance
Input Sync Signal
Horizontal, Vertical, & C-Sync
Sync on Green
The DA1912SX Distribution Amplifier is a state-of-
the-art product with a video bandwidth of 350 MHz,
enabling it to remain transparent to the video signal
passing through it. Each output is individually
buffered and is not affected by other output
loading.
1.5V p-p max
75 Ohms
TTL(+/-)
-0.3V
10 k Ohms
Impedance
Output Video Signal
Analog Signal
Impedance
Output Sync Signal
Composite Sync
Sync on Green
The DA1912SX accepts one input and offers up to
two outputs. Compensation for cable loss is
automatically made for distances up to 100 feet
when set normally, though the DA1912SX can
drive signals through longer runs depending on
source signal resolution and cable quality.
1.0V p-p/0.7V p-p
75 Ohms
TTL(+/-)
-0.3V
Impedance
22 Ohms
The DA1912SX is supplied with a 9V 500mA
External Power Adapter.
Frequency Compatibility
Typical Video Bandwidth
Minimum Video Bandwidth
Rise/Fall Time (ns)
Gain Default Setting
Cross-talk
Coupling
Power
External Power
380 MHz
350 MHz
1.4
TECHNICAL SPECIFICATIONS
3
1.05
-40dB @10 MHz
AC
FEATURES/DESCRIPTION
GENERAL
DA1912SX
1
Inputs
Input Connector
Outputs
4 BNC Female
2
9V 500mA external
adapter (included)
4 watts max.
Output Connectors
Compatibility
Two 4 BNC Female
Power Consumption
Table 3. DA1912SX Electrical
High resolution RGBS,
RGsB and RsGsBs,
Component, S-Video
and Composite Video
Table 1. DA1912SX General
3
Download from Www.Somanuals.com. All Manuals Search And Download.
DISTRIBUTION AMPLIFIERS
DESCRIPTION OF DA1912SX
4
4.3 SYNC LEVEL SWITCH
4.1 INPUT TERMINATION SWITCH
The Sync Level Switch allows the DA1912SX to
output a Sync Level of either 2V p-p or 4V p-p.
This switch should normally be set in the 4V
position. Some older display equipment may
require a sync level of 2V in which case this switch
may be used, but this would be rare.
The Input Termination Switch is normally set to
the ON position and provides 75 Ohms
termination for the Red, Green, and Blue
channels. By setting this switch in the OFF
position and using BNC "T" connectors, the input
may be looped to another DA1912SX, to a local
monitor, or to another piece of equipment, if
desired.
4.4 POWER
The DA1912SX requires the use of a 9V 500mA
power supply, which is included with the unit. A
variety of different power supplies are available for
international use.
4.2 VIDEO LEVEL SWITCH
The Video Level Switch can be set to either the
standard 0.7V output or to 1.0V output. When the
switch is set in the 1.0V output position, this
4.5 MOUNTING THE DA1912SX
provides approximately a 35% increase in video
signal level. This can be used in installations
where cable runs exceed 100 feet. It is not
recommended that this switch be set in the 1.0V
position for shorter cable lengths as the increased
level may reduce the life of CRT displays if they
are overdriven.
To mount the DA1912SX, Altinex offers "L" shape
mini-brackets, the DA1295SX, which provides
wings on either side of the unit, allowing it to be
installed on a rack plate, furniture, or a wall.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
DISTRIBUTION AMPLIFIERS
APPLICATION DIAGRAM
5
INSTALLING YOUR DISTRIBUTION
AMPLIFIER
Step 5. If the image is less than perfect, check all
the connections. The unit is very reliable
and seldom will be the cause of
malfunction. Poor quality cables may
often degrade the performance of the
product. Make sure that the cables used
are coaxial cables and that all pins are in
good condition.
6
Step 1. Make sure that the proper power supply is
being used with the unit. The use of an
incorrect power supply can result in
equipment damage not covered by
warranty.
Step 2. Connect the power cord to the unit and
plug it into the power outlet. The power
indicator LED on the front panel will light.
This indicates that the unit is operational.
Step 3. Connect the high resolution RGsB or
RGBS source to the DA1912SX using
coaxial cable with BNC connectors,
making sure that the colors match
correctly. Then connect one or two
monitors or projectors to the output(s) of
the DA1912SX. The monitors or
projectors must be scan-rate compatible
with the source signal - the DA1912SX
does not affect scan rate.
CONGRATULATIONS! YOU ARE DONE.
If you experience any problems, please call
1-800-258-4623 or 1-714-990-2300 for
international calls.
Step 4. The Input Termination switch should
normally be ON unless the input is being
looped to another unit. If the output cables
are longer than 100 feet, consider using
the Video Level Switch to increase the
gain on the outputs of the DA1912SX.
The Sync Level switch should normally be
in the 4V position.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
DISTRIBUTION AMPLIFIERS
OPERATION
7
ACCESSORIES
Model No.
8
The settings of the DA1912SX Distribution
Amplifier can be adjusted using Input Termination,
Video Level, and Sync Level switches as described
in Section 4. There are no other adjustments
necessary to operate the unit. The DA1912SX will
operate successfully as long as cables are
attached properly and other technical specifications
are followed.
Description
RACK MOUNTING BRACKETS
Rack/Wall/Furniture Mount Mini-
brackets (2-"L" shaped brackets)
POWER SUPPLIES
DA1295SX
9V 500mA Power Supply for US
9V 500mA Power Supply for UK
PS5502US
PS5512UK
PS5522AU
PS5532GR
PS5542JP
9V 500mA Power Supply for Australia
9V 500mA Power Supply for Germany
9V 500mA Power Supply for Japan
4 BNC to 4 BNC COAXIAL CABLE
Bulk Cable 4 coaxes (500ft minimum)
3 feet, 4 BNC to 4 BNC coaxial cable
6 feet, 4 BNC to 4 BNC coaxial cable
12 feet, 4 BNC to 4 BNC coaxial cable
25 feet, 4 BNC to 4 BNC coaxial cable
50 feet, 4 BNC to 4 BNC coaxial cable
75 feet, 4 BNC to 4 BNC coaxial cable
100 feet, 4 BNC to 4 BNC coaxial cable
150 feet, 4 BNC to 4 BNC coaxial cable
4 BNC to 4 BNC COAX (Super High
Resolution)
CB4100MR
CB4103MR
CB4106MR
CB4112MR
CB4125MR
CB4150MR
CB4175MR
CB41100MR
CB41150MR
Bulk Cable 4 coaxes (500ft minimum)
6 feet, 4 BNC to 4 BNC coaxial cable
12 feet, 4 BNC to 4 BNC coaxial cable
25 feet, 4 BNC to 4 BNC coaxial cable
50 feet, 4 BNC to 4 BNC coaxial cable
75 feet, 4 BNC to 4 BNC coaxial cable
100 feet, 4 BNC to 4 BNC coaxial cable
150 feet, 4 BNC to 4 BNC coaxial cable
CB4300MR
CB4306MR
CB4312MR
CB4325MR
CB4350MR
CB4375MR
CB43100MR
CB43150MR
6
Download from Www.Somanuals.com. All Manuals Search And Download.
DISTRIBUTION AMPLIFIERS
6
Why is the
Video Level
switch
The Video Level Switch can
be set to either the standard
0.7V output or to 1.0V
output. When the switch is
set in the 1.0V output
FREQUENTLY ASKED QUESTIONS
No: Question Answer
1 How many Compensation for cable loss
9
important?
feet of cable is automatically made for
can I use
with the
distances up to100 feet
when set normally, though
the DA1912SX can drive
signals through longer runs
depending on the source
signal resolution and cable
quality.
position, this provides
approximately a
DA1912SX
when the
Video Level
switch is set
in the 1V
35% increase in video signal
level. This can be used in
installations where cable
runs exceed 100 feet. It is
not recommended that this
switch be set in the 1.0V
position for shorter cable
lengths as the increased
level may reduce the life of
CRT displays if they are
overdriven.
position?
2
Can I use the It is not recommended since
one power supply is supplied
with each unit. Please
consider the PS5581SM, a
rack mount power supply.
DA1912SX
power supply
to power 2
units at the
same time?
Are outputs 1
& 2 of the
3
4
The DA1912SX has two
individually buffered outputs.
DA1912SX
buffered?
Why is the
Sync level
switch so
The Sync Level Switch
allows the DA1912SX to
output a Sync Level of either
2V p-p or 4V p-p. This switch
should normally be set in the
4V position. Some older
display equipment may
require a sync level of 2V in
which case this switch may
be used, but this would be
rare.
important?
5
Why and
The Input Termination
when should Switch is normally set to the
I use the
Input
Termination
switch?
ON position and provides 75
Ohm termination for the
Red, Green, and Blue
channels. By setting this
switch in the OFF position
and using BNC "T"
connectors, the input may be
looped to another
DA1912SX, to a local
monitor, or to some other
piece of equipment, if
desired.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
DISTRIBUTION AMPLIFIERS
11.2 RETURN POLICY
TROUBLESHOOTING GUIDE
10
It is very important to Altinex that you receive the
products that you have ordered and that this
product meets your expectations. In the unlikely
event, that an Altinex product needs to be
returned please follow the policies below:
We have carefully tested and have found no
problems in the supplied DA1912SX unit; however,
we would like to offer the following suggestions:
·
Please make sure that the input amplitude
levels are as follows:
Altinex will accept product returns for a period of
30 days from authorized Altinex dealers. Products
must be returned in an unopened package.
1. Analog signal less than 1.5V.
2. Sync signal less than 0.3V.
·
·
·
Please use Altinex supplied external Power
Supply/AC Adapter (9V, 500mA) only.
If a product has been opened, the restocking fees
will apply. For the restocking fee amount, please
contact an Altinex Sales Representative.
Please check the settings of Sync Level, Video
Level, and Input Termination Switches.
If the product is in your possession for more than
30 days, the restocking fees will apply.
Please make sure that a high quality of cables
is used. We recommend Altinex made cables
for best results.
Altinex will not accept any returns on cables or
custom products.
·
If the problem shows up after continuous
usage at higher voltage, higher temperature,
higher humidity, or at other extreme
environmental conditions, please correct the
problem.
If your product is in warranty and needs service,
contact the Altinex Sales Department for an RMA
(Return Material Authorization). Products returned
without an RMA number may experience a delay
in service.
ALTINEX POLICY
11
If your product is out of warranty and needs
service, contact the Altinex Sales Department for
an RMA (Return Material Authorization). Products
returned without an RMA number may experience
a delay in service. The service charges will be
quoted to you before the actual repairs are done.
11.1 LIMITED WARRANTY
Altinex warrants that its products and cables are
free from defects in materials under normal use
and service. This warranty is limited to repairing at
company’s factory any part or parts of the product,
which upon company’s examination shall disclose
to be, thus defective. Products considered
defective should be returned to company with
transportation charges pre-paid within 2 years (90
days for cables) from date of shipment to the
purchaser. The warranty is expressly instead of all
other warranties expressed or implied. Altinex
neither assumes nor authorizes any other person
to assume for it any other liability in connection
with the sale of the products. This warranty shall
not apply to any product that shall have been
repaired or altered outside of company’s factory in
any way so as, in its judgment, to affect its
stability or reliability, or that has been subject to
misuse, negligence, or accident.
11.3 CONTACT INFORMATION
Sales Department
Phone: 714-990-2300
Fax: 714-990-3303
Accounting Department
Phone: 714-990-6088
Fax: 714-990-5778
8
Download from Www.Somanuals.com. All Manuals Search And Download.
|