Altinex Stereo Amplifier DA1912SX User Manual

DISTRIBUTION AMPLIFIERS  
MANUAL PART NUMBER: 400-0007-003  
PRODUCT REVISION: 1  
DA1912SX  
1-IN, 2-OUT RGBS  
DISTRIBUTION AMPLIFIER  
USER’S GUIDE  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DISTRIBUTION AMPLIFIERS  
mounted, to a table or wall, use only Altinex  
PRECAUTIONS / SAFETY WARNINGS  
1
made mounting accessories, such as mini  
mount-brackets (DA1295FC) and cables for  
optimum setup.  
Please read this manual carefully before using your  
DA1912SX Distribution Amplifier. Keep this manual  
handy for future reference. These safety  
instructions are to ensure the long life of your  
DA1912SX and to prevent fire and shock hazard.  
Please read them carefully and heed all warnings.  
·
To turn off the main power, be sure to remove  
the cord from power outlet. The power outlet  
socket should be installed as near to the  
equipment as possible, and should be easily  
accessible.  
1.1 GENERAL  
·
Unauthorized personnel shall not open the unit  
since there are high-voltage components  
inside.  
·
·
Do not pull power cord or any cable that is  
attached to the DA1912SX Distribution  
Amplifier.  
·
Qualified Altinex service personnel, or their  
authorized representatives must perform all  
service.  
If the DA1912SX Distribution Amplifier is not  
used for an extended, disconnect the power  
cord from the power outlet.  
1.2 SAFETY GUIDELINES FOR THE RACK-  
MOUNTING OF THE DA1912SX  
1.4 CLEANING  
Unplug the DA1912SX power cord before  
·
·
·
·
Maximum operating ambient temperature is 35  
(degrees C).  
cleaning. Clean surfaces with a dry cloth.  
Never use strong detergents or solvents such  
as alcohol or thinner. Do not use a wet cloth or  
water to clean the unit.  
Never restrict the airflow through the device’s  
fan or vents.  
When installing equipment into a rack,  
distribute the units evenly. Otherwise,  
hazardous conditions may be created by an  
uneven weight distribution.  
1.5 FCC / CE NOTICE  
·
·
This device complies with the part 15 of the  
FCC Rules. Operation is subject to the  
following two conditions: (1) This device may  
not cause harmful interference, and (2) this  
device must accept any interference received,  
including interference that may cause  
undesired operation.  
·
Connect the unit to a properly rated supply  
circuit.  
·
Reliable Earthing (Grounding) of Rack-Mounted  
Equipment should be maintained.  
This equipment has been tested and found to  
comply with the limits for a Class A digital  
device, pursuant to Part 15 of the FCC Rules.  
These limits are designed to provide  
1.3 INSTALLATION  
·
For best results, place the DA1912SX  
Distribution Amplifier on a flat, level surface in  
a dry area away from dust and moisture.  
reasonable  
protection  
against  
harmful  
·
To prevent fire or shock, do not expose this  
unit to rain or moisture. Do not place the  
DA1912SX Distribution Amplifier in direct  
sunlight, near heaters or heat radiating  
appliances, or near any liquid. Exposure to  
direct sunlight, smoke, or steam can harm  
internal components.  
interference when the equipment is operated  
in a commercial environment. This equipment  
generates, uses, and can radiate radio  
frequency energy and, if not installed and used  
in accordance with the instruction manual, may  
cause  
harmful  
interference  
to  
radio  
communications. Operation of this equipment  
in a residential area is likely to cause harmful  
interference in which case the user will be  
required to correct the interference at his own  
expense.  
·
·
Handle the DA1912SX Distribution Amplifier  
carefully. Dropping or jarring can damage  
internal components.  
Do not place heavy objects on top of the  
DA1912SX. If the DA1912SX is to be  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
DISTRIBUTION AMPLIFIERS  
·
Any changes or modifications to the unit not  
expressly approved by Altinex, Inc. could void  
the user’s authority to operate the equipment.  
MECHANICAL  
DA1912SX  
Width (inches)  
Height (inches)  
Depth (inches)  
Weight (pounds)  
Ship Weight (pounds)  
Material  
4.56in (116mm)  
3.50in (89mm)  
0.94in (24mm)  
0.6lbs (0.27kg)  
2.0lbs (0.91kg)  
0.1” Al  
ABOUT YOUR DISTRIBUTION AMPLIFIER 2  
The DA1912SX Distribution Amplifier is designed  
to allow the connection of one high resolution  
RGsB or RGBS source to up two scan rate  
compatible monitors or projectors.  
Finish  
Top Panel  
Gray  
Lexan  
T° Operating  
T° Maximum  
Humidity  
10°C-35°C  
50°C  
Although designed to pass an RGBS signal format,  
the DA1912SX can also pass RGsB, Component  
Video (Y, R-Y, B-Y), S-Video (Y/C), and Composite  
Video by using the appropriate channels. Video  
sources must be passed through Red, Green,  
and/or Blue channels. The sync channel is not  
designed to pass video.  
90% non-condensing  
MTBF (calculations)  
40,000 hrs  
Table 2. DA1912SX Mechanical  
ELECTRICAL  
DA1912SX  
Input Video Signal  
Analog Signal  
Impedance  
Input Sync Signal  
Horizontal, Vertical, & C-Sync  
Sync on Green  
The DA1912SX Distribution Amplifier is a state-of-  
the-art product with a video bandwidth of 350 MHz,  
enabling it to remain transparent to the video signal  
passing through it. Each output is individually  
buffered and is not affected by other output  
loading.  
1.5V p-p max  
75 Ohms  
TTL(+/-)  
-0.3V  
10 k Ohms  
Impedance  
Output Video Signal  
Analog Signal  
Impedance  
Output Sync Signal  
Composite Sync  
Sync on Green  
The DA1912SX accepts one input and offers up to  
two outputs. Compensation for cable loss is  
automatically made for distances up to 100 feet  
when set normally, though the DA1912SX can  
drive signals through longer runs depending on  
source signal resolution and cable quality.  
1.0V p-p/0.7V p-p  
75 Ohms  
TTL(+/-)  
-0.3V  
Impedance  
22 Ohms  
The DA1912SX is supplied with a 9V 500mA  
External Power Adapter.  
Frequency Compatibility  
Typical Video Bandwidth  
Minimum Video Bandwidth  
Rise/Fall Time (ns)  
Gain Default Setting  
Cross-talk  
Coupling  
Power  
External Power  
380 MHz  
350 MHz  
1.4  
TECHNICAL SPECIFICATIONS  
3
1.05  
-40dB @10 MHz  
AC  
FEATURES/DESCRIPTION  
GENERAL  
DA1912SX  
1
Inputs  
Input Connector  
Outputs  
4 BNC Female  
2
9V 500mA external  
adapter (included)  
4 watts max.  
Output Connectors  
Compatibility  
Two 4 BNC Female  
Power Consumption  
Table 3. DA1912SX Electrical  
High resolution RGBS,  
RGsB and RsGsBs,  
Component, S-Video  
and Composite Video  
Table 1. DA1912SX General  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
DISTRIBUTION AMPLIFIERS  
DESCRIPTION OF DA1912SX  
4
4.3 SYNC LEVEL SWITCH  
4.1 INPUT TERMINATION SWITCH  
The Sync Level Switch allows the DA1912SX to  
output a Sync Level of either 2V p-p or 4V p-p.  
This switch should normally be set in the 4V  
position. Some older display equipment may  
require a sync level of 2V in which case this switch  
may be used, but this would be rare.  
The Input Termination Switch is normally set to  
the ON position and provides 75 Ohms  
termination for the Red, Green, and Blue  
channels. By setting this switch in the OFF  
position and using BNC "T" connectors, the input  
may be looped to another DA1912SX, to a local  
monitor, or to another piece of equipment, if  
desired.  
4.4 POWER  
The DA1912SX requires the use of a 9V 500mA  
power supply, which is included with the unit. A  
variety of different power supplies are available for  
international use.  
4.2 VIDEO LEVEL SWITCH  
The Video Level Switch can be set to either the  
standard 0.7V output or to 1.0V output. When the  
switch is set in the 1.0V output position, this  
4.5 MOUNTING THE DA1912SX  
provides approximately a 35% increase in video  
signal level. This can be used in installations  
where cable runs exceed 100 feet. It is not  
recommended that this switch be set in the 1.0V  
position for shorter cable lengths as the increased  
level may reduce the life of CRT displays if they  
are overdriven.  
To mount the DA1912SX, Altinex offers "L" shape  
mini-brackets, the DA1295SX, which provides  
wings on either side of the unit, allowing it to be  
installed on a rack plate, furniture, or a wall.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
DISTRIBUTION AMPLIFIERS  
APPLICATION DIAGRAM  
5
INSTALLING YOUR DISTRIBUTION  
AMPLIFIER  
Step 5. If the image is less than perfect, check all  
the connections. The unit is very reliable  
and seldom will be the cause of  
malfunction. Poor quality cables may  
often degrade the performance of the  
product. Make sure that the cables used  
are coaxial cables and that all pins are in  
good condition.  
6
Step 1. Make sure that the proper power supply is  
being used with the unit. The use of an  
incorrect power supply can result in  
equipment damage not covered by  
warranty.  
Step 2. Connect the power cord to the unit and  
plug it into the power outlet. The power  
indicator LED on the front panel will light.  
This indicates that the unit is operational.  
Step 3. Connect the high resolution RGsB or  
RGBS source to the DA1912SX using  
coaxial cable with BNC connectors,  
making sure that the colors match  
correctly. Then connect one or two  
monitors or projectors to the output(s) of  
the DA1912SX. The monitors or  
projectors must be scan-rate compatible  
with the source signal - the DA1912SX  
does not affect scan rate.  
CONGRATULATIONS! YOU ARE DONE.  
If you experience any problems, please call  
1-800-258-4623 or 1-714-990-2300 for  
international calls.  
Step 4. The Input Termination switch should  
normally be ON unless the input is being  
looped to another unit. If the output cables  
are longer than 100 feet, consider using  
the Video Level Switch to increase the  
gain on the outputs of the DA1912SX.  
The Sync Level switch should normally be  
in the 4V position.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
DISTRIBUTION AMPLIFIERS  
OPERATION  
7
ACCESSORIES  
Model No.  
8
The settings of the DA1912SX Distribution  
Amplifier can be adjusted using Input Termination,  
Video Level, and Sync Level switches as described  
in Section 4. There are no other adjustments  
necessary to operate the unit. The DA1912SX will  
operate successfully as long as cables are  
attached properly and other technical specifications  
are followed.  
Description  
RACK MOUNTING BRACKETS  
Rack/Wall/Furniture Mount Mini-  
brackets (2-"L" shaped brackets)  
POWER SUPPLIES  
DA1295SX  
9V 500mA Power Supply for US  
9V 500mA Power Supply for UK  
PS5502US  
PS5512UK  
PS5522AU  
PS5532GR  
PS5542JP  
9V 500mA Power Supply for Australia  
9V 500mA Power Supply for Germany  
9V 500mA Power Supply for Japan  
4 BNC to 4 BNC COAXIAL CABLE  
Bulk Cable 4 coaxes (500ft minimum)  
3 feet, 4 BNC to 4 BNC coaxial cable  
6 feet, 4 BNC to 4 BNC coaxial cable  
12 feet, 4 BNC to 4 BNC coaxial cable  
25 feet, 4 BNC to 4 BNC coaxial cable  
50 feet, 4 BNC to 4 BNC coaxial cable  
75 feet, 4 BNC to 4 BNC coaxial cable  
100 feet, 4 BNC to 4 BNC coaxial cable  
150 feet, 4 BNC to 4 BNC coaxial cable  
4 BNC to 4 BNC COAX (Super High  
Resolution)  
CB4100MR  
CB4103MR  
CB4106MR  
CB4112MR  
CB4125MR  
CB4150MR  
CB4175MR  
CB41100MR  
CB41150MR  
Bulk Cable 4 coaxes (500ft minimum)  
6 feet, 4 BNC to 4 BNC coaxial cable  
12 feet, 4 BNC to 4 BNC coaxial cable  
25 feet, 4 BNC to 4 BNC coaxial cable  
50 feet, 4 BNC to 4 BNC coaxial cable  
75 feet, 4 BNC to 4 BNC coaxial cable  
100 feet, 4 BNC to 4 BNC coaxial cable  
150 feet, 4 BNC to 4 BNC coaxial cable  
CB4300MR  
CB4306MR  
CB4312MR  
CB4325MR  
CB4350MR  
CB4375MR  
CB43100MR  
CB43150MR  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
DISTRIBUTION AMPLIFIERS  
6
Why is the  
Video Level  
switch  
The Video Level Switch can  
be set to either the standard  
0.7V output or to 1.0V  
output. When the switch is  
set in the 1.0V output  
FREQUENTLY ASKED QUESTIONS  
No: Question Answer  
1 How many Compensation for cable loss  
9
important?  
feet of cable is automatically made for  
can I use  
with the  
distances up to100 feet  
when set normally, though  
the DA1912SX can drive  
signals through longer runs  
depending on the source  
signal resolution and cable  
quality.  
position, this provides  
approximately a  
DA1912SX  
when the  
Video Level  
switch is set  
in the 1V  
35% increase in video signal  
level. This can be used in  
installations where cable  
runs exceed 100 feet. It is  
not recommended that this  
switch be set in the 1.0V  
position for shorter cable  
lengths as the increased  
level may reduce the life of  
CRT displays if they are  
overdriven.  
position?  
2
Can I use the It is not recommended since  
one power supply is supplied  
with each unit. Please  
consider the PS5581SM, a  
rack mount power supply.  
DA1912SX  
power supply  
to power 2  
units at the  
same time?  
Are outputs 1  
& 2 of the  
3
4
The DA1912SX has two  
individually buffered outputs.  
DA1912SX  
buffered?  
Why is the  
Sync level  
switch so  
The Sync Level Switch  
allows the DA1912SX to  
output a Sync Level of either  
2V p-p or 4V p-p. This switch  
should normally be set in the  
4V position. Some older  
display equipment may  
require a sync level of 2V in  
which case this switch may  
be used, but this would be  
rare.  
important?  
5
Why and  
The Input Termination  
when should Switch is normally set to the  
I use the  
Input  
Termination  
switch?  
ON position and provides 75  
Ohm termination for the  
Red, Green, and Blue  
channels. By setting this  
switch in the OFF position  
and using BNC "T"  
connectors, the input may be  
looped to another  
DA1912SX, to a local  
monitor, or to some other  
piece of equipment, if  
desired.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
DISTRIBUTION AMPLIFIERS  
11.2 RETURN POLICY  
TROUBLESHOOTING GUIDE  
10  
It is very important to Altinex that you receive the  
products that you have ordered and that this  
product meets your expectations. In the unlikely  
event, that an Altinex product needs to be  
returned please follow the policies below:  
We have carefully tested and have found no  
problems in the supplied DA1912SX unit; however,  
we would like to offer the following suggestions:  
·
Please make sure that the input amplitude  
levels are as follows:  
Altinex will accept product returns for a period of  
30 days from authorized Altinex dealers. Products  
must be returned in an unopened package.  
1. Analog signal less than 1.5V.  
2. Sync signal less than 0.3V.  
·
·
·
Please use Altinex supplied external Power  
Supply/AC Adapter (9V, 500mA) only.  
If a product has been opened, the restocking fees  
will apply. For the restocking fee amount, please  
contact an Altinex Sales Representative.  
Please check the settings of Sync Level, Video  
Level, and Input Termination Switches.  
If the product is in your possession for more than  
30 days, the restocking fees will apply.  
Please make sure that a high quality of cables  
is used. We recommend Altinex made cables  
for best results.  
Altinex will not accept any returns on cables or  
custom products.  
·
If the problem shows up after continuous  
usage at higher voltage, higher temperature,  
higher humidity, or at other extreme  
environmental conditions, please correct the  
problem.  
If your product is in warranty and needs service,  
contact the Altinex Sales Department for an RMA  
(Return Material Authorization). Products returned  
without an RMA number may experience a delay  
in service.  
ALTINEX POLICY  
11  
If your product is out of warranty and needs  
service, contact the Altinex Sales Department for  
an RMA (Return Material Authorization). Products  
returned without an RMA number may experience  
a delay in service. The service charges will be  
quoted to you before the actual repairs are done.  
11.1 LIMITED WARRANTY  
Altinex warrants that its products and cables are  
free from defects in materials under normal use  
and service. This warranty is limited to repairing at  
company’s factory any part or parts of the product,  
which upon company’s examination shall disclose  
to be, thus defective. Products considered  
defective should be returned to company with  
transportation charges pre-paid within 2 years (90  
days for cables) from date of shipment to the  
purchaser. The warranty is expressly instead of all  
other warranties expressed or implied. Altinex  
neither assumes nor authorizes any other person  
to assume for it any other liability in connection  
with the sale of the products. This warranty shall  
not apply to any product that shall have been  
repaired or altered outside of company’s factory in  
any way so as, in its judgment, to affect its  
stability or reliability, or that has been subject to  
misuse, negligence, or accident.  
11.3 CONTACT INFORMATION  
Sales Department  
Phone: 714-990-2300  
Fax: 714-990-3303  
Accounting Department  
Phone: 714-990-6088  
Fax: 714-990-5778  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  

Addonics Technologies Network Card ST5BDVES User Manual
AEG Juicer ESF 1031 User Manual
Agilent Technologies TV Converter Box 04291 90031 User Manual
Aiphone Telephone TB 20T User Manual
Air King Ventilation Hood ASF120 User Manual
Allied Telesis Switch AR44xS series User Manual
American DJ DJ Equipment Octo Beam User Manual
ATO Speaker System SCM20ASL PRO User Manual
Audiovox Satellite Radio XMCK30P User Manual
Beko Oven OIM 22300 User Manual