Altinex Stereo Amplifier DA1203RM User Manual

DISTRIBUTION AMPLIFIERS  
MANUAL PART NUMBER: 400-0003-003  
PRODUCT REVISION: 1  
DA1203RM  
1-IN, 3-OUT RGBS  
DISTRIBUTION AMPLIFIER  
USER’S GUIDE  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DISTRIBUTION AMPLIFIERS  
to a table or wall, use only Altinex made  
PRECAUTIONS / SAFETY WARNINGS  
1
mounting accessories (Rack Mount Shelf  
DA1298FC, Rack Mount Ears DA1299RM) and  
cables for optimum setup.  
Please read this manual carefully before using your  
DA1203RM Distribution Amplifier. Keep this  
manual handy for future reference. These safety  
instructions are to ensure the long life of your  
DA1203RM and to prevent fire and shock hazard.  
Please read them carefully and heed all warnings.  
·
To turn off main power, be sure to remove the  
cord from power outlet. The power outlet socket  
should be installed as near to the equipment as  
possible, and should be easily accessible.  
1.1 GENERAL  
·
·
Do not pull power cord or any cable that is  
attached to the DA1203RM Distribution  
Amplifier.  
·
Unauthorized personnel shall not open the unit  
since there are high-voltage components inside.  
If the DA1203RM Distribution Amplifier is not to  
be used for an extended period of time,  
disconnect the power cord from the power  
outlet.  
·
Qualified Altinex service personnel, or their  
authorized representatives must perform all  
service.  
1.2 SAFETY GUIDELINES FOR THE RACK-  
MOUNTING OF THE DA1203RM  
1.4 CLEANING  
·
Unplug the DA1203RM power cord before  
cleaning. Clean surfaces with a dry cloth. Never  
use strong detergents or solvents such as  
alcohol or thinner. Do not use a wet cloth or  
water to clean the unit.  
·
·
·
Maximum operating ambient temperature is 35  
(degrees C).  
Never restrict the air flow through the devices’  
fan or vents.  
When installing equipment into a rack,  
distribute the units evenly. Otherwise,  
hazardous conditions may be created by an  
uneven weight distribution.  
1.5 FCC / CE NOTICE  
·
·
This device complies with part 15 of the FCC  
Rules. Operation is subject to the following two  
conditions: (1) This device may not cause  
harmful interference, and (2) this device must  
accept any interference received, including  
interference that may cause undesired  
operation.  
·
·
Connect the unit to a properly rated supply  
circuit.  
Reliable Earthing (Grounding) of Rack-  
Mounted Equipment should be maintained.  
1.3 INSTALLATION  
This equipment has been tested and found to  
comply with the limits for a Class A digital  
device, pursuant to Part 15 of the FCC Rules.  
These limits are designed to provide reasonable  
protection against harmful interference when the  
·
For best results, place the DA1203RM  
Distribution Amplifier on a flat, level surface in a  
dry area away from dust and moisture.  
·
To prevent fire or shock, do not expose this unit  
to rain or moisture. Do not place the DA1203RM  
Distribution Amplifier in direct sunlight, near  
heaters or heat radiating appliances, or near any  
liquid. Exposure to direct sunlight, smoke, or  
steam can harm internal components.  
equipment is operated in  
a
commercial  
environment. This equipment generates, uses,  
and can radiate radio frequency energy and, if  
not installed and used in accordance with the  
instruction manual, may cause harmful  
interference to radio communications. Operation  
of this equipment in a residential area is likely to  
cause harmful interference in which case the  
user will be required to correct the interference  
at his own expense.  
·
·
Handle the DA1203RM Distribution Amplifier  
carefully. Dropping or jarring can damage  
internal components.  
Do not place heavy objects on top of the  
DA1203RM. If the DA1203RM is to be mounted,  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
DISTRIBUTION AMPLIFIERS  
TECHNICAL SPECIFICATION  
3
·
Any changes or modifications to the unit not  
expressly approved by Altinex, Inc. could void  
the user’s authority to operate the equipment.  
FEATURES/DESCRIPTION  
GENERAL  
DA1203RM  
1
Inputs  
Input Connector  
Outputs  
Output Connectors  
Compatibility  
ABOUT YOUR DISTRIBUTION AMPLIFIER 2  
4-BNC Female  
3
Three 4-BNC Female  
High resolution RGBS,  
RGsB and RsGsBs,  
Component, S-Video  
and Composite Video  
The DA1203RM Distribution Amplifier is designed  
to allow the connection of a single computer or  
other video source to as many as three scan-rate  
compatible display devices.  
Though primarily designed to pass RGBS format  
signals, the DA1203RM can also pass RGsB,  
Component Video (Y, R-Y, B-Y), S-Video (Y/C),  
and Composite Video by using the appropriate  
analog channels (Red, Green, Blue).  
Table 1. DA1203RM General  
MECHANICAL  
DA1203RM  
Material  
Finish  
Top Panel  
0.1” Al  
Gray  
Lexan  
The analog channels (Red, Green, Blue) are  
designed to pass video levels up to 1.5V p-p  
offering a 0.15% differential gain and 0.16 degree  
differential phase to assure the highest quality  
video signal.  
Height (inches)  
Width (inches)  
Depth (inches)  
Weight (pounds)  
Ship Weight (pounds)  
T° Operating  
T° Maximum  
Humidity  
3.40in (86mm)  
8.50in (216mm)  
4.75in (121mm)  
2.6lbs (1.18kg)  
3.8lbs (1.73kg)  
10°C-35°C  
The DA1203RM offers switches for Gain, Sync  
Level, and Sync Polarity. The Gain Switch boosts  
the output of the amplifier by 35% for use, with long  
cable runs. The DA1203RM uses AGC (automatic  
gain control) circuitry, which converts all incoming  
sync levels to either 4V p-p or 2V p-p. This AGC  
circuitry is selectable with the Sync Level switch.  
This enables it to be compatible, with current and  
older display equipment. The Sync Polarity switch  
reverses the polarity of the incoming sync for  
compatibility with various displays.  
50°C  
90% non-condensing  
MTBF (calculations)  
40,000 hrs  
Table 2. DA1203RM Mechanical  
ELECTRICAL  
DA1203RM  
Input Video Signals  
Analog Signal  
Impedance  
1.5V p-p max  
75 Ohms  
The DA1203RM Distribution Amplifier is a state-of-  
the-art product with a video bandwidth of 350 MHz,  
enabling it to remain transparent to the video signal  
passing through it. Each output is individually  
buffered and is not affected by other output  
loading.  
Input Sync Signals  
Horizontal, Vertical, & C-Sync  
Sync on Green  
Impedance  
Output Video Signals  
Analog Signal  
Fall/Rise Time (ns)  
Impedance  
Output Sync Signals  
Composite Sync  
Sync on Green  
TTL(+/-)  
-0.3V  
10 k Ohms  
1.0V p-p/0.7V p-p  
1.4  
The DA1203RM offers an internal 90-140/200-  
240V power supply and can be rack mounted using  
optional accessories hardware ( DA1299RM – rack  
ears for single unit and DA1298RM – rack shelf for  
two units side-by-side).  
75 Ohms  
TTL(+/-)  
-0.3V  
22 Ohms  
Impedance  
Frequency Compatibility  
Horizontal  
Vertical  
15-200 kHz  
47-180 Hz  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
DISTRIBUTION AMPLIFIERS  
Minimum Video Bandwidth  
Typical Video Bandwidth  
Cable Equalization  
Coupling  
350MHz @ -3dB  
380MHz @ -3dB  
3dB @120MHz  
DC  
-40dB @10MHz  
Cross-talk  
Power  
Internal Power Supply  
Power Consumption  
90-140V/200-240V  
10 watts max.  
Table 3. DA1203RM Electrical  
DESCRIPTION OF DA1203RM  
4
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
DISTRIBUTION AMPLIFIERS  
4.3 VIDEO LEVEL SWITCH  
4.1 SYNC POLARITY SWITCH  
The Video Level Switch can be set to either the  
standard 0.7V output or to 1.0V output. When  
the switch is set in the 1.0V output position, this  
provides approximately a 35% increase in the  
video signal level. This can be used in  
installations where cable runs exceed 150 feet.  
It is not recommended that this switch be set in  
the 1.0V position for shorter cable lengths as the  
increased level may reduce the life of CRT  
displays if they are over-driven.  
The SYNC POLARITY switch is located on the  
back panel of the DA1203RM. It has two  
switching positions — one designated (+) and  
the other (-). By setting the sync polarity switch  
to (+), the signal is processed unchanged and  
the sync polarity of the output signal matched  
the sync polarity of the unit. By setting sync  
polarity to (-) the sync polarity of the output is  
changed to the opposite of the input.  
4.2 SYNC LEVEL SWITCH  
4.4 POWER  
The SYNC LEVEL switch is also located on the  
back panel of the DA1203RM and has two  
positions for switching — sync level of 2V and  
sync level of 4V. Most often a 4V sync level is  
used. This should be considered as default  
setting. The 2V setting allows compatibility with  
some older equipment that would be overdriven  
if a stronger signal were used.  
The DA1203RM offers an internal 90-140/200-  
240V power supply. A variety of different power  
supplies are available for international use.  
APPLICATION DIAGRAM  
5
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
DISTRIBUTION AMPLIFIERS  
INSTALLING YOUR DISTRIBUTION  
AMPLIFIER  
OPERATION  
7
6
The settings of the DA1203RM Distribution  
Amplifier can be adjusted using Input Termination,  
Video Level and Sync Level switches as described  
in Section no. 4. There are no other adjustments  
necessary to operate the unit. The DA1203RM will  
operate successfully as long as cables are  
attached properly and other technical specifications  
are followed.  
Step 1.  
Step 2.  
Step 3.  
Make sure that the proper power supply  
is being used with the DA1203RM.  
Note: The use of an incorrect power  
supply can result in equipment damage  
not covered by warranty.  
Connect the power cord to the  
DA1203RM and plug it into the power  
outlet. The power indicator LED on the  
front panel will light. This indicates that  
the unit is operational.  
ACCESSORIES  
Model No.  
8
Description  
Connect the high resoluti on RGsB or  
RGBS source to the DA1203RM using  
coaxial cable with BNC connectors,  
making sure that the colors match  
correctly. Then connect one or two  
monitors or projectors to the output(s) of  
the DA1203RM. The monitors or  
projectors must be scan-rate compatible  
with the source signal - the DA1203RM  
does not affect scan rate.  
TABLE MOUNT BRACKET  
Table Mount Bracket for 2U High, ½  
rack units  
TM1276  
RACK MOUNTING BRACKETS  
Rack Mount shelf for two units  
Rack Mount shelf for single unit  
POWER CABLES  
DA1298RM  
DA1299RM  
9V 500mA Power Supply for US  
9V 500mA Power Supply for UK  
9V 500mA Power Supply for Australia  
9V 500mA Power Supply for Germany  
HIGH RESOLUTION 4 BNC to 4 BNC  
COAXIAL CABLE  
PC5301US  
PC5302UK  
PC5303AU  
PC5304GR  
Step 5.  
If the image is less than perfect, check  
all the connections. Also check the  
settings of the switches. The default  
settings are Sync Polarity (+), Sync  
Level (4V), Video Level (0.7V). Check  
all the connections. The unit is very  
reliable and seldom will this be the  
cause of malfunction. Poor quality  
cables may often degrade the  
performance of the product. Make sure  
that the cables used are coaxial cables  
and that all pins are in good condition.  
Bulk Cable 4 coaxes (500ft minimum)  
3 feet, 4 BNC to 4 BNC coaxial cable  
6 feet, 4 BNC to 4 BNC coaxial cable  
12 feet, 4 BNC to 4 BNC coaxial cable  
25 feet, 4 BNC to 4 BNC coaxial cable  
50 feet, 4 BNC to 4 BNC coaxial cable  
75 feet, 4 BNC to 4 BNC coaxial cable  
100 feet, 4 BNC to 4 BNC coaxial cable  
150 feet, 4 BNC to 4 BNC coaxial cable  
SUPER HIGH RESOLUTION 4 BNC to  
4 BNC COAX  
CB4100MR  
CB4103MR  
CB4106MR  
CB4112MR  
CB4125MR  
CB4150MR  
CB4175MR  
CB41100MR  
CB41150MR  
CONGRATULATIONS! YOU ARE DONE.  
If you experience any problems, please call  
1-800-258-4623 or 1-714-990-2300 for  
international calls.  
Bulk Cable 4 coaxes (500ft minimum)  
6 feet, 4 BNC to 4 BNC coaxial cable  
12 feet, 4 BNC to 4 BNC coaxial cable  
25 feet, 4 BNC to 4 BNC coaxial cable  
50 feet, 4 BNC to 4 BNC coaxial cable  
75 feet, 4 BNC to 4 BNC coaxial cable  
100 feet, 4 BNC to 4 BNC coaxial cable  
150 feet, 4 BNC to 4 BNC coaxial cable  
CB4300MR  
CB4306MR  
CB4312MR  
CB4325MR  
CB4350MR  
CB4375MR  
CB43100MR  
CB43150MR  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
DISTRIBUTION AMPLIFIERS  
when the  
Video Level  
switch is set in level. This can be used in  
approximately a 35%  
increase in video signal  
FREQUENTLY ASKED QUESTIONS  
No. Question Answer  
9
1
2
3
What is a  
Distribution  
Amplifier?  
A Distribution Amplifier is a  
device that allows you to  
connect a single video  
source to multiple display  
devices, such as monitors  
or projectors used in  
the 1.0V  
output  
position?  
installations where cable  
runs exceed 150 feet. It is  
not recommended that this  
switch be set in the 1.0V  
position for shorter cable  
lengths as the increased  
level may reduce the life of  
CRT displays if they are  
over-driven.  
presentation applications.  
When do I use In some cases, you need a  
the  
DA1203RM?  
non-simultaneous  
connection of a single C-  
Video source or a single S-  
Video source to as many  
as three different display  
or recording devices.  
The DA1203RM can pass  
RGBS, RGsB, Component  
Video (Y, R-Y, B-Y), S-  
Video (Y/C), and  
TROUBLESHOOTING GUIDE  
10  
We have carefully tested and have found no  
problems in the supplied DA1203RM unit; however,  
we would like to offer the following suggestions .  
Which signal  
formats can be  
passed  
·
Please make sure that input amplitude levels  
are as follows:  
through?  
Composite Video by using  
the appropriate analog  
channels (Red, Green,  
Blue).  
1. Analog signal is less than 1.5V.  
2. Sync signal is less than 0.3V.  
·
·
Please check the settings of Sync Level, Video  
level and Sync Polarity Switches.  
4
5
6
When do I use By setting the sync polarity  
“+” position of  
the Sync  
Polarity  
switch to (+) the signal is  
processed unchanged and  
the sync polarity of the  
output signal matches the  
sync polarity of the  
DA1203RM. By setting  
sync polarity to (-) the sync  
polarity of the output is  
changed to the opposite of  
the input.  
Please make sure that the proper quality of  
cables is used. We recommend Altinex made  
cables for best results.  
switch?  
·
If the problem shows up after continuous  
usage at higher voltage, higher temperature,  
higher humidity, or at other extreme  
environmental conditions, please correct those  
conditions.  
When do I use The SYNC LEVEL switch  
the Sync Level has two positions — 2V  
switch?  
and 4V. Most often a 4V  
Sync Level is used. This  
should be considered as  
default setting. The 2V  
setting allows compatibility  
with some older equipment  
that would be overdriven if  
a stronger signal were  
being used.  
What do I have This provides  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
DISTRIBUTION AMPLIFIERS  
If your product is out of warranty and needs  
ALTINEX POLICY  
11  
service, contact the Altinex Sales Department  
for an RMA (Return Material Authorization).  
Products returned without an RMA number may  
experience a delay in service. The service  
charges will be quoted to you before the actual  
repairs are done.  
11.1 LIMITED WARRANTY  
Altinex warrants that its products and cables are  
free from defects in materials under normal use  
and service. This warranty is limited to repairing  
at company’s factory any part or parts of the  
product, which upon company’s examination  
shall disclose to be, thus defective. Products  
considered defective should be returned to  
company with transportation charges pre-paid  
within 2 years (90 days for cables) from date of  
shipment to the purchaser. The warranty is  
expressly instead of all other warranties  
expressed or implied. Altinex neither assumes  
nor authorizes any other person to assume for it  
any other liability in connection with the sale of  
the products. This warranty shall not apply to  
any product that shall have been repaired or  
altered outside of company’s factory in any way  
so as, in its judgment, to affect its stability or  
reliability, or that has been subject to misuse,  
negligence or accident.  
11.3 CONTACT INFORMATION  
Sales Department  
Phone:  
Fax:  
714-990-2300  
714-990-3303  
Accounting Department  
Phone:  
Fax:  
714-990-6088  
714-990-5778  
11.2 RETURN POLICY  
It is very important that you receive the product  
that you have ordered and that this product  
fulfills your need. In the unlikely event that an  
Altinex product needs to be returned, please  
follow the policies below:  
Altinex will accept product returns for a period of  
30 days from authorized Altinex dealers.  
Products must be returned in an unopened  
package.  
If product has been opened, the restocking fees  
will apply. For the restocking fee amount, please  
contact an Altinex Sales Representative.  
If product is in your possession for more than 30  
days, the restocking fees will apply.  
Altinex will not accept any returns on cables or  
custom products.  
If your product is in warranty and needs service,  
contact the Altinex Sales Department for an  
RMA (Return Material Authorization). Products  
returned without an RMA number may  
experience a delay in service.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  

Accton Technology Network Hardware CheetaHub Power Fast Ethernet Dual Speed Stackable Hubs User Manual
Acoustic Research Portable Radio XMC90 User Manual
AEG Oven BP8314001 User Manual
Agri Fab Spreader 45 0324 User Manual
AIS Network Router AI2524 User Manual
AMD Typewriter x86 User Manual
Atlona Pet Fence AT HD BIR40SR User Manual
ATN Binoculars 330 User Manual
Behringer Guitar IAXE629 User Manual
Beko Clothes Dryer DV 2570 x User Manual