SPECIAL APPLICATION
MANUAL PART NUMBER: 400-0517-001
CP450 Series
MULTITOUCH
TOUCH SCREEN CONTROLLERS
USER’S GUIDE
Download from Www.Somanuals.com. All Manuals Search And Download.
SPECIAL APPLICATION
1.4 FCC NOTICE
PRECAUTIONS / SAFETY WARNINGS
1
·
This device complies with Part 15 of the FCC
Rules. Operation is subject to the following two
conditions: (1) This device may not cause
harmful interference, and (2) this device must
accept any interference received, including
interference that may cause undesired
operation.
Please read this manual carefully before using your
CP450 and keep it handy for future reference.
These safety instructions are to ensure the long life
of your CP450 and to prevent fire and shock
hazards. Please read them carefully and heed all
warnings.
1.1 GENERAL
·
This equipment has been tested and found to
comply with the limits for a Class A digital
device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable
protection against harmful interference when the
·
Do not open the unit or power supply case, there
are high-voltage components inside.
·
There are no user serviceable parts inside.
Qualified ALTINEX service personnel must
perform all service on the CP450.
equipment is operated in
a
commercial
environment. This equipment generates, uses,
and can radiate radio frequency energy and if
not installed and used in accordance with
instructions found herein, may cause harmful
interference to radio communications. Operation
of this equipment in a residential area is likely to
cause harmful interference in which case the
user will be required to correct the interference
at his own expense.
·
Handle the CP450 carefully.
1.2 HANDLING
·
For best results, place the CP450 in a dry area
away from dust and moisture.
·
To prevent fire or shock, do not expose this unit
to water or moisture. Do not place the CP450 in
direct sunlight, near heaters, or heat-radiating
appliances, or near any liquid. Exposure to direct
sunlight, smoke, or steam can harm internal
components.
·
Any changes or modifications to the unit not
expressly approved by ALTINEX, Inc. could void
the user’s authority to operate the equipment.
·
·
Handle the CP450 carefully. Dropping or jarring
can damage the unit.
Do not pull any cables that are attached to the
CP450.
·
·
Do not place heavy objects on top of the CP450.
If the CP450 is not used for an extended period,
disconnect the adapter from the wall to avoid
fire, shock, and loss of power.
1.3 CLEANING
·
·
Unplug the CP450 adapter before cleaning.
Clean only with a dry cloth. Never use strong
detergents or solvents such as alcohol or
thinner. Do not use a wet cloth or water to clean
the unit. Do not open the unit to clean.
400-0517-001
2
Download from Www.Somanuals.com. All Manuals Search And Download.
SPECIAL APPLICATION
The built-in wireless LAN can be used to control
remote devices through a wireless router or directly
to a remote IP. As an information interface in a
classroom, public information kiosk, etc., the
wireless connection can also be used to upload
real-time data to the CP450 ensuring the most
up-to-date information is available to the user.
ABOUT YOUR CP450
2
CP450 SERIES
TOUCH SCREEN CONTROLLERS
The CP450 Series of touch screen controllers are
ideal for a wide variety of applications that include
the following: multimedia control systems, general
computing, advertising, real-time data terminals,
interactive self-service centers, digital surveillance,
etc. Each controller is a computer running Windows
XP Embedded that includes these key features:
The Bluetooth module inside each CP450 is
compatible with most peripheral devices like
headsets, barcode readers, printers, cell phones,
and more.
The CP450 can be mounted to a stand for table
use; it can be wall or rack mounted. The 7, 8, and
10-inch models have standard 75mm x 75mm
VESA mounting on the back of the unit. The 15, 17,
· Touch Screen
· Wireless Local Area Network (WLAN)
· Bluetooth Personal Area Network (PAN)
· 2 COM ports and 2 LAN ports
· Integrated Dual Speakers
· Enhanced Write Filter (EWF) Protection
· AVSnap™ Professional AV System Integration Tool
and
19-inch
models
have
standard
100mm x 100mm spacing, while the 12-inch has
both 75 and 100mm spacing.
AVSnap provides a complete environment for
designing simple to sophisticated graphical user
interfaces (GUIs). AVSnap is preinstalled on each
CP450 making it easy to integrate into any control
environment. Design high-quality GUIs with
minimum effort by way of user-friendly toolbars for
buttons, volume controls, progress bars, and much
more. AVSnap incorporates a simple programming
language with an organized interface that makes
even complex programming code easy to read and
maintain.
The CP450 senses “touch” from a finger, stylus,
pen, pencil, gloved finger, or other tool. The touch
screen is very accurate and responsive to the
touch. The CP450 incorporates effortlessly into PC
based control systems.
The two COM ports can control virtually any serial
device using standard RS-232 communication.
The two LAN ports allow connectivity to a local area
network or a direct connection to another TCP/IP
device. For added flexibility, consider the ALTINEX
AC301-201 TCP/IP to RS-232 Adapter.
adapter allows RS-232 communication through a
standard LAN connection.
Everything needed to start is included in a sample
application. Use the predefined procedures and
functions to communicate with devices over
RS-232 or LAN, or create your own custom
subroutines. If you can program Crestron or AMX,
you can program AVSnap.
This
The AC301-201 has both serial (DB9) and network
(RJ-45) connections. The AC301-201 connects to a
serial device using its DB9 connection, and to the
LAN using standard network cable. AVSnap,
HyperTerminal, or other RS-232 communication
software can then be used to control the serial
device using the IP address of the adapter in place
of the COM port. In this way, a single controller can
be used to control any number of serial devices
using their unique IP address.
The EWF prevents changes to the internal drive
without specific intent and access. This protects the
BIOS and operating system files from becoming
corrupt due to power outages or other power
interruptions.
400-0517-001
3
Download from Www.Somanuals.com. All Manuals Search And Download.
SPECIAL APPLICATION
TECHNICAL SPECIFICATIONS
3
MECHANICAL
Material
CP450-007
ABS w/ PC Plastic frame
Black
Specifications are subject to change.
Color
FEATURES/
CP450-007
DESCRIPTION
Height
5.5 in (140 mm)
8.9 in (226 mm)
1.6 in (41 mm)
1.4 lb (0.6 kg)
2.8 lb (1.3 kg)
0-50°C
Details
Width
LCD Size
7”
Depth
Resolution
LCD Colors
800 x 480 max.
262K
Weight
AMD Geode™ LX 800
500 MHz
CPU
Shipping Weight (approx.)
T° Operating
T° Maximum
Humidity
RAM
512 MB
802.11 b/g
Bluetooth
CF Type II
WLAN
60°C
PAN
90% non-condensing
40,000 hrs (min.)
Solid State Drive (SSD)
External Connections
12VDC IN
MTBF (calculations)
DC Jack (1)
Type A F (2)
DB9 M (2)
Table 2. CP450-007 Mechanical
USB 2.0
ELECTRICAL
CP450-007
RS-232 COM
LAN (network)
Mounting Holes
Agency Approval
EMC
External Connections
USB 2.0 Voltage
USB 2.0 Current
LAN Speed
RJ-45 F (2)
5V
3x3 in (75x75 mm)
100 mA max.
10/100 Mbps
+/-15V
CE, FCC Class B, CCC
UL, CB
Safety
RS-232 Input Range
RS-232 Sensitivity
Speaker Output
Power Consumption
+12VDC
Accessories Included
+/- 3V
Power Adapter+
AC Power Cord
+12VDC
1.5 W max.
(from adapter)
20W max.
Hardware
Mounting screws
Optional Accessories
Stand
AC403-101
AC403-104
AC403-109
Panel Mount
Wall Mount
Table 3. CP450-007 Electrical
Table 1. CP450-007 General
400-0517-001
4
Download from Www.Somanuals.com. All Manuals Search And Download.
SPECIAL APPLICATION
FEATURES/
DESCRIPTION
MECHANICAL
Material
CP450-008
ABS w/ PC Plastic frame
Black
CP450-008
Details
LCD Size
Resolution
LCD Colors
8.4”
800 x 600 max.
262K
Color
Height
7.2 in (184 mm)
9.2 in (234 mm)
1.7 in (42 mm)
1.8 lb (0.8 kg)
3.1 lb (1.4 kg)
0-50°C
Width
AMD Geode™ LX 800
500 MHz
CPU
Depth
RAM
512 MB
802.11 b/g
Bluetooth
CF Type II
Weight
WLAN
Shipping Weight (approx.)
T° Operating
T° Maximum
Humidity
PAN
Solid State Drive (SSD)
External Connections
12VDC IN
60°C
DC Jack (1)
Type A F (2)
DB9 M (2)
90% non-condensing
40,000 hrs (min.)
USB 2.0
MTBF (calculations)
RS-232 COM
LAN (network)
Mounting Holes
Agency Approval
EMC
Table 5. CP450-008 Mechanical
RJ-45 F (2)
3x3 in (75x75 mm)
ELECTRICAL
CP450-008
External Connections
USB 2.0 Voltage
USB 2.0 Current
LAN Speed
CE, FCC Class B, CCC
UL, CB
5V
Safety
100 mA max.
10/100 Mbps
+/-15V
Accessories Included
Power Adapter+
AC Power Cord
+12VDC
RS-232 Input Range
RS-232 Sensitivity
Speaker Output
Power Consumption
+12VDC
Hardware
Mounting screws
Optional Accessories
Stand
+/- 3V
AC403-101
AC403-104
AC403-109
1.5 W max.
(from adapter)
20W max.
Panel Mount
Wall Mount
Table 4. CP450-008 General
Table 6. CP450-008 Electrical
400-0517-001
5
Download from Www.Somanuals.com. All Manuals Search And Download.
SPECIAL APPLICATION
FEATURES/
DESCRIPTION
MECHANICAL
Material
CP450-010
ABS w/ PC Plastic frame
Black
CP450-010
Details
LCD Size
Resolution
LCD Colors
10.4”
800 x 600 max.
262K
Color
Height
8.9 in (227 mm)
10.9 in (276 mm)
2.0 in (51 mm)
3.1 lb (1.4 kg)
5.0 lb (2.3 kg)
0-50°C
Width
AMD Geode™ LX 800
500 MHz
CPU
Depth
RAM
512 MB
802.11 b/g
Bluetooth
CF Type II
Weight
WLAN
Shipping Weight (approx.)
T° Operating
T° Maximum
Humidity
PAN
Solid State Drive (SSD)
External Connections
12VDC IN
60°C
DC Jack (1)
Type A F (2)
DB9 M (2)
90% non-condensing
40,000 hrs (min.)
USB 2.0
MTBF (calculations)
RS-232 COM
LAN (network)
Mounting Holes
Agency Approval
EMC
Table 8. CP450-010 Mechanical
RJ-45 F (2)
3x3 in (75x75 mm)
ELECTRICAL
CP450-010
External Connections
USB 2.0 Voltage
USB 2.0 Current
LAN Speed
CE, FCC Class B, CCC
UL, CB
5V
Safety
100 mA max.
10/100 Mbps
+/-15V
Accessories Included
Power Adapter+
AC Power Cord
+12VDC
RS-232 Input Range
RS-232 Sensitivity
Speaker Output
Power Consumption
+12VDC
Hardware
Mounting screws
Optional Accessories
Stand
+/- 3V
AC403-102
AC403-105
AC403-109
1.5 W max.
(from adapter)
25W max.
Panel Mount
Wall Mount
Table 7. CP450-010 General
Table 9. CP450-010 Electrical
400-0517-001
6
Download from Www.Somanuals.com. All Manuals Search And Download.
SPECIAL APPLICATION
FEATURES/
DESCRIPTION
MECHANICAL
Material
CP450-012
ABS w/ PC Plastic frame
Black
CP450-012
Details
LCD Size
Resolution
LCD Colors
12.1”
1024 x 768 max.
262K
Color
Height
9.7 in (246 mm)
12.0 in (304 mm)
2.0 in (51 mm)
4.0 lb (1.8 kg)
5.6 lb (2.5 kg)
0-50°C
Width
AMD Geode™ LX 800
500 MHz
CPU
Depth
RAM
512 MB
802.11 b/g
Bluetooth
CF Type II
Weight
WLAN
Shipping Weight (approx.)
T° Operating
T° Maximum
Humidity
PAN
Solid State Drive (SSD)
External Connections
12VDC IN
60°C
DC Jack (1)
Type A F (2)
DB9 M (2)
90% non-condensing
40,000 hrs (min.)
USB 2.0
MTBF (calculations)
RS-232 COM
LAN (network)
Table 11. CP450-012 Mechanical
RJ-45 F (2)
3x3 in (75x75 mm)
and
ELECTRICAL
CP450-012
Mounting Holes
4x4 in (100x100 mm)
External Connections
USB 2.0 Voltage
Agency Approval
EMC
5V
CE, FCC Class B, CCC
UL, CB
USB 2.0 Current
LAN Speed
100 mA max.
10/100 Mbps
+/-15V
Safety
Accessories Included
Power Adapter+
AC Power Cord
+12VDC
RS-232 Input Range
RS-232 Sensitivity
Speaker Output
Power Consumption
+12VDC
Hardware
Mounting screws
+/- 3V
Optional Accessories
Stand
1.5 W max.
(from adapter)
29W max.
AC403-102
AC403-105
AC403-109
Panel Mount
Wall Mount
Table 12. CP450-012 Electrical
Table 10. CP450-012 General
400-0517-001
7
Download from Www.Somanuals.com. All Manuals Search And Download.
SPECIAL APPLICATION
FEATURES/
DESCRIPTION
MECHANICAL
Material
CP450-015
ABS w/ PC Plastic frame
Black
CP450-015
Details
LCD Size
Resolution
LCD Colors
15”
1024 x 768 max.
262K
Intel® Celeron®
Mobile 1GHz
Color
Height
12.2 in (309 mm)
15.5 in (394 mm)
2.4 in (61 mm)
8.2 lb (3.7 kg)
10.1 lb (4.6 kg)
0-45°C
Width
CPU
Depth
RAM
1 GB
Weight
WLAN
802.11 b/g
Bluetooth
CF Type II
Shipping Weight (approx.)
T° Operating
T° Maximum
Humidity
PAN
Solid State Drive (SSD)
External Connections
12VDC IN
60°C
DC Jack (1)
Type A F (4)
90% non-condensing
40,000 hrs (min.)
USB 2.0
MTBF (calculations)
RS-232 COM
LAN (GbE)
DB9 M (2)
Table 14. CP450-015 Mechanical
RJ-45 F (2)
VGA Out
15-PIN HD F (1)
3.5 mm F (1)
ELECTRICAL
CP450-015
AUDIO Out
External SATA
Mounting Holes
Agency Approval
EMC
External Connections
USB 2.0 Voltage
eSATA type I (1)
4x4 in (100x100 mm)
5V
USB 2.0 Current
LAN Speed
100 mA max.
1000 Mbps (GbE)
+/-15V
CE, FCC Class B, CCC
UL, CB
Safety
RS-232 Input Range
RS-232 Sensitivity
Speaker Output
Power Consumption
+12VDC
Accessories Included
+/- 3V
Power Adapter+
AC Power Cord
+12VDC
1.5 W max.
(from adapter)
43W max.
Hardware
Mounting screws
Optional Accessories
Stand
AC403-103
AC403-106
AC403-110
Panel Mount
Wall Mount
Table 15. CP450-015 Electrical
Table 13. CP450-015 General
400-0517-001
8
Download from Www.Somanuals.com. All Manuals Search And Download.
SPECIAL APPLICATION
FEATURES/
DESCRIPTION
MECHANICAL
Material
CP450-017
ABS w/ PC Plastic frame
Black
CP450-017
Details
LCD Size
Resolution
LCD Colors
17”
1280 x 1024 max.
16.7M
Intel® Celeron®
Mobile 1GHz
Color
Height
13.8 in (350 mm)
16.9 in (428 mm)
2.6 in (66 mm)
11.9 lb (5.4 kg)
14.9 lb (6.8 kg)
0-45°C
Width
CPU
Depth
RAM
1 GB
Weight
WLAN
802.11 b/g
Bluetooth
CF Type II
Shipping Weight (approx.)
T° Operating
T° Maximum
Humidity
PAN
Solid State Drive (SSD)
External Connections
12VDC IN
60°C
DC Jack (1)
Type A F (4)
90% non-condensing
40,000 hrs (min.)
USB 2.0
MTBF (calculations)
RS-232 COM
LAN (GbE)
DB9 M (2)
Table 17. CP450-017 Mechanical
RJ-45 F (2)
VGA Out
15-PIN HD F (1)
3.5 mm F (1)
ELECTRICAL
CP450-017
AUDIO Out
External SATA
Mounting Holes
Agency Approval
EMC
External Connections
USB 2.0 Voltage
eSATA type I (1)
4x4 in (100x100 mm)
5V
USB 2.0 Current
LAN Speed
100 mA max.
1000 Mbps (GbE)
+/-15V
CE, FCC Class B, CCC
UL, CB
Safety
RS-232 Input Range
RS-232 Sensitivity
Speaker Output
Power Consumption
+12VDC
Accessories Included
+/- 3V
Power Adapter+
AC Power Cord
+12VDC
1.5 W max.
(from adapter)
63W max.
Hardware
Mounting screws
Optional Accessories
Stand
AC403-103
AC403-107
AC403-110
Panel Mount
Wall Mount
Table 18. CP450-017 Electrical
Table 16. CP450-017 General
400-0517-001
9
Download from Www.Somanuals.com. All Manuals Search And Download.
SPECIAL APPLICATION
FEATURES/
DESCRIPTION
MECHANICAL
Material
CP450-019
ABS w/ PC Plastic frame
Black
CP450-019
Details
LCD Size
Resolution
LCD Colors
19”
1280 x 1024 max.
16.7M
Intel® Celeron®
Mobile 1GHz
Color
Height
15.1 in (383 mm)
18.5 in (470 mm)
2.6 in (67 mm)
12.8 lb (5.8 kg)
14.9 lb (6.8 kg)
0-45°C
Width
CPU
Depth
RAM
1 GB
Weight
WLAN
802.11 b/g
Bluetooth
CF Type II
Shipping Weight (approx.)
T° Operating
T° Maximum
Humidity
PAN
Solid State Drive (SSD)
External Connections
12VDC IN
60°C
DC Jack (1)
Type A F (4)
90% non-condensing
40,000 hrs (min.)
USB 2.0
MTBF (calculations)
RS-232 COM
LAN (GbE)
DB9 M (2)
Table 20. CP450-019 Mechanical
RJ-45 F (2)
VGA Out
15-PIN HD F (1)
3.5 mm F (1)
ELECTRICAL
CP450-019
AUDIO Out
External SATA
Mounting Holes
Agency Approval
EMC
External Connections
USB 2.0 Voltage
eSATA type I (1)
4x4 in (100x100 mm)
5V
USB 2.0 Current
LAN Speed
100 mA max.
1000 Mbps (GbE)
+/-15V
CE, FCC Class B, CCC
UL, CB
Safety
RS-232 Input Range
RS-232 Sensitivity
Speaker Output
Power Consumption
+12VDC
Accessories Included
+/- 3V
Power Adapter+
AC Power Cord
+12VDC
3 W max.
Hardware
Mounting screws
(from adapter)
68W max.
Optional Accessories
Stand
AC403-103
AC403-108
AC403-110
Panel Mount
Wall Mount
Table 21. CP450-019 Electrical
Table 19. CP450-019 General
400-0517-001
10
Download from Www.Somanuals.com. All Manuals Search And Download.
SPECIAL APPLICATION
PRODUCT DESCRIPTION
4
400-0517-001
11
Download from Www.Somanuals.com. All Manuals Search And Download.
SPECIAL APPLICATION
APPLICATION DIAGRAMS
DIAGRAM 1: TYPICAL SETUP
5
400-0517-001
12
Download from Www.Somanuals.com. All Manuals Search And Download.
SPECIAL APPLICATION
DIAGRAM 2: CP450-007 DIMENSIONS
8.4" [214 mm]
1.6" [41 mm]
0.6" [16 mm]
8.9" [226 mm]
5.9" [151 mm]
400-0517-001
13
Download from Www.Somanuals.com. All Manuals Search And Download.
SPECIAL APPLICATION
DIAGRAM 3: CP450-008 DIMENSIONS
8.7" [220 mm]
1.7" [42 mm]
0.7" [17 mm]
9.2" [234 mm]
6.7" [170 mm]
400-0517-001
14
Download from Www.Somanuals.com. All Manuals Search And Download.
SPECIAL APPLICATION
DIAGRAM 4: CP450-010 DIMENSIONS
10.0" [253 mm]
2.0" [51 mm]
0.9" [24 mm]
10.9" [276 mm]
8.3" [212 mm]
400-0517-001
15
Download from Www.Somanuals.com. All Manuals Search And Download.
SPECIAL APPLICATION
DIAGRAM 5: CP450-012 DIMENSIONS
11.0" [279 mm]
2.0" [51 mm]
0.9" [24 mm]
12.0" [304 mm]
9.8" [248 mm]
400-0517-001
16
Download from Www.Somanuals.com. All Manuals Search And Download.
SPECIAL APPLICATION
DIAGRAM 6: CP450-015 DIMENSIONS
12.6" [320 mm]
2.4" [61 mm]
1.2" [30 mm]
15.5" [394 mm]
12.1" [306 mm]
400-0517-001
17
Download from Www.Somanuals.com. All Manuals Search And Download.
SPECIAL APPLICATION
DIAGRAM 7: CP450-017 DIMENSIONS
13.8" [351 mm]
2.6" [66 mm]
1.3" [34 mm]
16.9" [428 mm]
13.4" [340 mm]
400-0517-001
18
Download from Www.Somanuals.com. All Manuals Search And Download.
SPECIAL APPLICATION
DIAGRAM 8: CP450-019 DIMENSIONS
15.1" [384 mm]
2.6" [67 mm]
1.4" [36 mm]
18.5" [470 mm]
14.9" [378 mm]
400-0517-001
19
Download from Www.Somanuals.com. All Manuals Search And Download.
SPECIAL APPLICATION
INSTALLING YOUR CP450
6
SETUP
The installation and setup steps may be performed
concurrently in order to save time.
Step 1. Prepare the control software using your
normal software development station. The
CP450 is not required. We recommend
using AVSnap as the control software. It
is free, easy to use, and has many
features designed for use with the CP450.
At the time of purchase, determine if the CP450 will
be mounted on a stand, wall, or panel. The
mounting stand or brackets can be purchased from
ALTINEX.
Step 2. Debug the control software using the
device for which it was written. The
CP450 is a normal computer and its COM
and LAN ports work the same as a
desktop computer.
NOTE: The mounting holes on the rear of the
units are VESA standard. The 7-10 inch
models use 75x75 mm spacing, the 15-19
inch models use 100x100 mm, and the
12 inch has both.
Step 3. When the control software is complete,
INSTALLATION
copy all necessary files to a USB drive.
Step 1. Determine the best location for installing
the CP450. At a minimum, the CP450 will
require AC power for its power adapter.
Step 4. Connect the power adapter provided with
the CP450 to AC power and then to the
CP450.
ADDITIONAL CONSIDERATIONS
Step 5. The CP450 boots automatically and
launches a MultiTouch demo written in
AVSnap. You can view the demo, or
escape out of AVSnap and return to the
desktop.
·
If the CP450 will control RS-232
equipment directly from its serial ports,
RS-232 cables must be routed to the
devices.
·
·
If the CP450 will connect to the
network, LAN access and network
cables are required.
Step 6. Install the USB drive into the CP450 and
copy the files over to the “C” drive. If any
application software is required, install it
at this time. Once all the software has
been installed, close all open applications
and run the COMMIT batch file located on
the desktop. This will commit the changes
made to the internal drive.
Make sure there is access to the USB
ports. The USB ports are accessible
from the bottom of the unit and should
not be blocked by mounting hardware,
cables, etc.
NOTE: If an installation wizard requests a restart
to complete the installation, answer NO.
The COMMIT batch file must be run first.
Step 2. Route all cables required for the CP450 to
the installation locations. Make sure the
cables are long enough to allow for
service loops and to be routed neatly to
their destinations.
Step 7. Restart the CP450 and verify all the
changes are present. Place a shortcut to
the new control software into the startup
folder and remove the AVSnap demo.
Run the COMMIT batch file again and
restart the CP450.
Step 3. Have qualified personnel install the
mounting brackets (or other hardware) for
the CP450.
Step 8. The unit is now operational. Verify the
CP450 boots up and automatically
launches the control software.
400-0517-001
20
Download from Www.Somanuals.com. All Manuals Search And Download.
SPECIAL APPLICATION
7.3 INSTALLING FILES AND APPLICATIONS
OPERATION
7
The CP450 utilizes the Windows XP Embedded
EWF to protect the CP450’s internal memory from
accidental or unauthorized changes. The EWF
appears to read and write from the internal drive,
but executes everything in RAM. All changes WILL
be lost after reset or shutdown unless the changes
are committed to memory. Three batch files are
provided for direct control over the EWF and should
be used cautiously.
The CP450 is designed for use in a fixed
application where the system boots up directly into
the user application and does not allow access to
the operating system. The application and GUI
interface are normally created using a standard
desktop computer and then installed onto the
CP450 using a USB drive or network connection.
Once set-up, the CP450 will work trouble-free
without user intervention.
1. COMMIT.BAT – Write to hard drive
7.1 POWER UP and SHUTDOWN
This batch file resides on the desktop and writes
the RAM data onto the hard drive for permanent
storage while EWF is enabled. Close open
applications before running this batch file or the
changes may not be committed to memory.
The CP450 boots automatically as soon as power
is applied. There is no need to press the power
switch on the bottom of the unit.
In most
installations, the system boots directly into the
end-user application.
2. ENABLE.BAT – Turn on EWF
The CP450 can be powered down using the
shutdown/power off option from the START menu,
or directly from an AVSnap application using the
“App1.Shutdown” function.
This batch file resides in the root directory and
turns on the EWF. In this mode, no changes
made to the system are saved unless the
COMMIT batch file is executed. This is the
default condition for all CP450s.
7.2 PREPARING CONTROL SOFTWARE
It is not recommended to design and create control
software directly on the CP450. In most situations,
it is easier and faster to write and debug control
software on a standard desktop computer and then
transfer the completed file when ready. However, if
the CP450 needs to be programmed “in place”, use
an external USB keyboard and mouse. Simply plug
in the devices and wait for the system to recognize
the new hardware and load the drivers.
3. DISABLE.BAT – Turn off EWF
This batch file resides in the root directory and
turns off the EWF. In this mode, the system
operates like a normal computer reading and
writing data directly to the hard drive.
WARNING
When the EWF is turned off, the user MUST
shutdown the computer properly. If power is
turned off or lost without executing the normal
shutdown procedure, data can be lost, or
corrupted, including the BIOS and operating
system (OS). If the BIOS or OS are damaged,
the entire system can become unusable.
Remember, the CP450 employs the Enhanced
Write Filter (EWF) to protect the contents of the
internal drive. Read the next section carefully
before attempting to install, create, or edit any data
files or applications on the CP450. If not executed
properly, changes will be lost.
7.3.1 INSTALLING LARGE FILES
The best way to create and edit on the CP450 is to
use a USB drive plugged into the bottom of the unit
and make changes directly to the USB drive then
copy the final files to the CP450’s “C” drive.
If the application or file is too large for the available
RAM, the operation will be aborted. Use the disable
batch file before installing the software. Make sure
to reset the EWF when done.
400-0517-001
21
Download from Www.Somanuals.com. All Manuals Search And Download.
SPECIAL APPLICATION
7.4 AVSNAP
TROUBLESHOOTING GUIDE
8
AVSnap provides a complete environment for
designing simple to sophisticated graphical user
interfaces (GUIs). AVSnap is preinstalled on each
CP450 making it easy to integrate into any control
environment.
We have carefully tested and found no problems in
the supplied CP450; however, we would like to
offer suggestions for the following:
8.1 POWER IS NOT ON
Cause 1: No AC power.
Everything needed to start is included in a sample
application. Use the predefined procedures and
functions to communicate with devices over
RS-232 or LAN, or create your own custom
functions. In addition to standard communication
and control, the functions below are useful for
typical touch screen applications and can be
assigned to buttons or placed in startup and
shutdown routines. The samples shown here
require an application object named “App1” to be
part of the application.
Solution: Verify the adapter is plugged into a
working AC outlet and that the outlet
has power. Use only the AC adapter
that was shipped with the unit.
Cause 2: Adapter is not plugged into
CP450.
Solution: Verify the DC power plug coming
from the AC adapter is plugged all
the way into the CP450.
Cause 3: The CP450 has a problem.
App1.Shutdown.............. Close the application and
turn off the computer.
Solution: If there is AC power to the adapter
and the LED still does not turn on,
the CP450 or the power adapter
may require service. Call ALTINEX
at (714) 990-2300.
App1.SleepMonitor......... Turn off monitor power.
App1.Quit ....................... Quit
the
runtime
environment and return to
edit mode if running an
AMT file. If running an
EXE file, quit the EXE
and close the application.
8.2 SOFTWARE/FILES ARE MISSING
Cause 1: Changes were not committed to
memory.
App1.Stop....................... Stop
the
executable
Solution: Make changes to the CP450 then
run the COMMIT batch file on the
desktop before shutting down or
restarting the CP450.
application.
Use with EXE files only!!!
App1.Powersave ............ Hibernate (standby) the
computer per display
Cause 2: File/application was open when
COMMIT was executed.
property settings.
App1.RunScreensaver.... Launch the screensaver.
If no screensaver is
Solution: Any files that are open for editing
must be closed before executing the
COMMIT batch file. For best results,
close all applications and files before
running the COMMIT batch file.
installed this command
has no effect.
400-0517-001
22
Download from Www.Somanuals.com. All Manuals Search And Download.
SPECIAL APPLICATION
ALTINEX POLICIES
9
9.1 LIMITED WARRANTY/RETURN POLICIES
Please see the ALTINEX website at
www.altinex.com for details on warranty and
return policies.
9.2 CONTACT INFORMATION
ALTINEX, Inc.
592 Apollo Street
Brea, CA 92821 USA
TEL: 714 990-2300
TOLL FREE: 1-800-ALTINEX
WEB: www.altinex.com
E-MAIL: [email protected]
400-0517-001
23