Allied Telesis Switch 8PS User Manual

AT-GS900/8PS  
Gigabit Ethernet POE+ Switch  
AT-GS900/8PS Installation Guide  
PN 613-001687 Rev. A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Electrical Safety and Emissions Standards  
This product meets the following standards.  
U.S. Federal Communications Commission  
Radiated Energy  
Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15  
of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the  
equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency  
energy and, if not installed and used in accordance with this instruction manual, may cause harmful interference to radio  
communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case  
the user will be required to correct the interference at his own expense.  
Note: Modifications or changes not expressly approved of by the manufacturer or the FCC, can void your right to operate  
this equipment.  
Industry Canada  
This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.  
Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.  
RFI Emissions  
FCC Part 15 Class A  
CISPR 22 Class A  
EN55022:2006/A:2007 Class A  
Warning: In a domestic environment this product may cause radio interference in  
which case the user may be required to take adequate measures.  
Immunity  
EN55024  
Electrical Safety EN60950 (TUV) T-Mark  
UL 60950 (CULUS  
C-TICK  
)
CE  
Environmental Compliance  
EU-RoHS compliant  
WEEE  
China RoHS compliant  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Translated Safety Statements  
Important: The indicates that a translation of the safety statement is available in a PDF  
document titled “Translated Safety Statements” posted on the Allied Telesis website at  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Contents  
Preface ................................................................................................................................................................................11  
Chapter 1: Overview ..........................................................................................................................................................15  
Chapter 2: Installation .......................................................................................................................................................31  
Chapter 3: Troubleshooting ..............................................................................................................................................47  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Contents  
Appendix A: Technical Specifications .............................................................................................................................53  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Figures  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Figures  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
Tables  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Tables  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Preface  
This guide contains the installation instructions for the AT-GS900/8PS  
Gigabit Ethernet POE+ Switch. This preface contains the following  
sections:  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Preface  
Symbol Conventions  
This document uses the following conventions:  
Note  
Notes provide additional information.  
Caution  
Cautions inform you that performing or omitting a specific action  
may result in equipment damage or loss of data.  
Warning  
Warnings inform you that performing or omitting a specific action  
may result in bodily injury.  
Warning  
Warnings inform you that an eye and skin hazard exists due to the  
presence of a Class 1 laser device.  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
AT-GS900/8PS Switch Installation Guide  
Contacting Allied Telesis  
If you need assistance with this product, you may contact Allied Telesis  
technical support by going to the Support & Services section of the Allied  
Telesis web site at www.alliedtelesis.com/support. You can find links for  
the following services on this page:  
24/7 Online Support - Enter our interactive support center to  
search for answers to your questions in our knowledge database,  
check support tickets, learn about RMAs, and contact Allied  
Telesis technical experts.  
USA and EMEA phone support - Select the phone number that  
best fits your location and customer type.  
Hardware warranty information - Learn about Allied Telesis  
warranties and register your product online.  
Replacement Services - Submit a Return Merchandise  
Authorization (RMA) request via our interactive support center.  
Documentation - View the most recent installation guides, user  
guides, software release notes, white papers and data sheets for  
your product.  
Software Updates - Download the latest software releases for your  
product.  
For sales or corporate contact information, go to  
www.alliedtelesis.com/purchase and select your region.  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Preface  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 1  
Overview  
This chapter describes the AT-GS900/8PS Layer 2 Gigabit Ethernet  
Switch. The sections in the chapter are.  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Chapter 1: Overview  
Features  
Here are the hardware features of the AT-GS900/8PS Gigabit Ethernet  
Switch.  
General  
Supports 18 Gbps non-blocking switch fabric  
Transparent to VLAN packets  
Support for jumbo frames up to 9216 bytes at 100% forwarding  
rate  
Twisted Pair  
Ports  
8 ports  
10Base-TX, 100Base-T and 1000Base-T compliant  
IEEE 802.3u Auto-Negotiation compliant  
Auto-MDI/MDIX  
RJ-45 connectors  
100 meters (328 feet) maximum operating distance  
IEEE 802.3x flow control in 10/100Base-TX full-duplex operation  
IEEE 802.3x back pressure in 10/100Base-TX half-duplex  
operation  
IEEE803.3z 1000Base-T flow control  
LEDs  
Speed and link/activity LEDs for the twisted pair ports  
Link/activity LEDs for the SFP slots  
PoE and PoE Limit LEDs  
Power LED  
PoE Ports  
SFP Slots  
PoE support for ports 1 - 4  
Class 3 (IEEE 802 af) supported on four ports  
Class 4 (IEEE 802 at) supported on two ports  
One SFP slot  
Support 1000Base-SX/LX transceivers  
Note  
SFP transceivers must be purchased separately. For a list of  
supported transceivers, contact your Allied Telesis distributor or  
reseller.  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
AT-GS900/8PS Switch Installation Guide  
Power over  
Ethernet  
PoE and PoE+ supported on the 10/100/1000Base-T ports 1 - 4 on  
the AT-GS900/8PS switch  
Supports powered device classes 0 through 4  
Max power limit of 75 watts for the switch  
Max power limit of 30 watts per port  
Port prioritization  
Alternative A Mode  
Installation  
Options  
19-inch equipment rack  
Desk or tabletop  
Wall  
Power  
Conservation  
High-efficiency internal power supply  
Power scaling based on traffic loads on ports operating at 1000  
Mbps and cable length (port power scaling not available at 10 or  
100 Mbps)  
Power shutdown/sleep mode on unconnected ports  
MAC Address  
Table  
Up to 8 KB  
Automatic learning and aging  
Dimensions  
Width - 280 mm (11.0 in), Depth - 180 mm (7.1 in), Height - 44 mm  
(1.7 in)  
Operating  
Conditions  
Operating temperature range of 0° C to 40° C (32° F to 104° F)  
Operating humidity range of 5% to 90% non-condensing  
Storage humidity range of 5% to 95% non-condensing  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
Chapter 1: Overview  
Front and Back Panels  
Figure 1 illustrates the front panel of the AT-GS900/8PS Gigabit Ethernet  
Switch.  
AT-GS900/8  
PoE  
System  
PoE Limit  
LEDs  
10/100/1000Base-T  
Twisted Pair Ports  
Port  
LEDs  
1000M  
SFP Slot  
LEDs  
Figure 1. AT-GS900/8PS Front Panel  
The switch back panel is illustrated in Figure 2.  
Figure 2. Back Panel  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
AT-GS900/8PS Switch Installation Guide  
Twisted Pair Ports  
The AT-GS900/8PS Gigabit Ethernet Switch features 8 twisted pair ports,  
respectively, that are 10Base-T, 100Base-TX, and 1000Base-T compliant.  
The port speeds and duplex modes are determined automatically with  
IEEE 802.3u Auto-Negotiation. The ports have a maximum operating  
distance of 100 m (328 feet).  
The twisted pair ports feature 8-pin RJ-45 connectors. For the port pinouts,  
Cable The cable requirements for the ports on the AT-GS900/8PS are listed in  
Specifications  
Table 1. Twisted Pair Cable Specifications for the AT-GS900/8PS  
Cable Type  
10Mbps  
Yes  
100Mbps  
Yes  
1000Mbps  
Standard TIA/EIA 568-B-  
compliant Category 3 shielded  
or unshielded cabling with 100  
ohm impedance and a  
No  
frequency of 16 MHz.  
Standard TIA/EIA 568-A-  
compliant Category 5 or TIA/  
EIA 568-B-compliant Enhanced  
Category 5 (Cat 5e) shielded or  
unshielded cabling with 100  
ohm impedance and a  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
frequency of 100 MHz.  
Standard TIA/EIA 568-B-  
compliant Category 6 or 6a  
shielded cabling.  
Note  
The twisted pair ports on the switch feature auto-MDI when  
operating at 10, 100, or 1000 Mbps. A port is configured as MDI or  
MDI-X when it is connected to an end-node. Consequently, you can  
use a straight-through or cross-over twisted pair cable when  
connecting any type of network device to a port on the switch.  
MDI/MDI-X The ports feature auto-MDI, which automatically configures the ports as  
MDI or MDI-X. This feature allows you to use straight-through or cross-  
over twisted pair cables when connecting to the end-nodes.  
Mode  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
Chapter 1: Overview  
Auto-Negotiation Each AT-GS900/8PS switch port is configured for Auto-Negotiation mode  
which determines the speed and duplex mode. Each end-node connected  
to a twisted-pair port should also be configured for Auto-Negotiation mode.  
This insures that the speed and duplex mode is matched on each end.  
Mode  
Note  
If an end-node connected to a AT-GS900/8PS twisted-pair port is  
set to a fixed speed and duplex, a speed and duplex mismatch may  
occur which can cause a reduction in the data flow.  
Flow Control and When two end-nodes are set to different speeds, an Ethernet switch with  
the slower data rate capability may randomly be flooded with more data  
Back Pressure  
than it can process and may need to signal the opposite end-node to stop  
sending data until it is ready again. How a switch signals an end-node to  
stop transmitting data differs depending on the duplex mode of the  
Ethernet ports.  
A port operating in full-duplex mode uses PAUSE frames, as specified in  
the IEEE 802.3x standard, to momentarily stop the transmission of data  
from an end-node. Whenever a switch port wants an end-node to stop  
transmitting data because it is being flooded by data, it issues a PAUSE  
frame. This frame instructs the end-node to temporarily cease  
transmission. The switch continues to issue PAUSE frames until it is ready  
to receive data again from the end-node. This is referred to as flow control.  
A twisted pair port operating at half-duplex mode stops its end-node from  
transmitting data by forcing a collision. A collision on an Ethernet network  
occurs when two end-nodes attempt to transmit data using the same data  
link at the same time. A collision causes the end-nodes to momentarily  
stop sending data. When a switch port has received more data than it can  
process, it needs to temporarily stop its end-node from transmitting data.  
The port does this by forcing a collision on the data link, which stops the  
opposite end-node from transmitting any more data. After the switch is  
ready to receive data again, the switch stops forcing collisions. This is  
referred to as back pressure.  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
AT-GS900/8PS Switch Installation Guide  
SFP Port  
The AT-GS900/8PS features one SFP uplink port (Port 9). This port is  
capable of supporting one 1000SX/LX SFP module. Refer to the AT-  
GS900/8PS product data sheet for information concerning the specific  
SFP models supported and fiber cable specifications. See “Contacting  
Allied Telesis” on page 13 for a link to the AT-GS900/8PS product page.  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Chapter 1: Overview  
LEDs  
The System, PoE, 10/100/1000Base-T and SFP LEDs are shown in  
Figure 3. AT-GS900/8PS LEDs  
Table 2 describes the system LED.  
Table 2. System LED  
LED  
State  
Description  
Solid Green The input AC power is within the normal  
operating range.  
POWER  
Off  
The switch is not receiving AC power.  
Table 3 describes the Power over Ethernet (PoE) LEDs:  
Table 3. Power over Ethernet LEDs  
LED  
State  
Description  
Solid Green Power is supplied to the PD.  
Blinking  
Green  
Port is overloaded, short-circuited.  
Power is not supplied to the PD.  
PoE  
OFF  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
AT-GS900/8PS Switch Installation Guide  
Table 3. Power over Ethernet LEDs  
Total PoE delivered power is between 70 W  
and 75 W (Guard Band). While in this state,  
Solid Green demand for PoE power to any additional  
PoE ports will be denied.  
PoE Limit  
Blinking  
Green  
The demand for PoE Power has exceeded  
the max PoE power limit (75 W). The low  
priority port(s) are disconnected as required  
so the total PoE power delivered is less than  
75 W.  
Off  
Total PoE power delivered is below 70W.  
Table 4 describes the LEDs for the 10/100/1000Base-T ports.  
Table 4. 10/100/1000Base-T Port LEDs  
LED  
State  
Description  
Steady  
Green  
The port has established a link to a network  
device.  
L/A (link/  
activity)  
Blinking  
Green  
The port is transmitting or receiving network  
packets.  
Off  
The port has not established a link with a  
network device.  
Steady  
Green  
The operating speed of the port is 1000  
Mbps.  
SPD  
(speed)  
Off  
The operating speed of the port is 10 or 100  
Mbps or the port has not established a link  
with a network device.  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Chapter 1: Overview  
Table 5 describes the LEDs for the SFP slots.  
Table 5. SFP Slot LEDs  
LED  
State  
Description  
Solid Green The SFP transceiver has established a link  
with a network device, but is not transmitting  
or receiving network packets.  
L/A (link/  
activity)  
Blinking  
Green  
The SFP transceiver is transmitting or  
receiving network packets.  
The port on the SFP transceiver has not  
established a link with an end-node or the  
transceiver slot is empty.  
Off  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
AT-GS900/8PS Switch Installation Guide  
Power Over Ethernet  
The AT-GS900/8PS switch features Power over Ethernet (PoE) only on  
ports 1 - 4. PoE is used to supply power to network devices over the same  
twisted pair cables that carry the network traffic.  
The main advantage of PoE is that it can make it easier to install a  
network. The selection of a location for a network device is often limited by  
whether there is a power source nearby. This often limits equipment  
placement or requires the added time and cost of having additional  
electrical sources installed. But with PoE, you can install PoE-compatible  
devices wherever they are needed without having to worry about whether  
there are power sources nearby.  
A device that provides PoE to other network devices is referred to as  
power sourcing equipment (PSE). The AT-GS900/8PS switch acts as a  
PSE unit by adding DC power to the network cable, thus functioning as a  
central power source for another network device.  
Devices that receive their power from a PSE are called powered devices  
(PD). Examples include wireless access points, IP telephones, webcams,  
and even other Ethernet switches.  
The switch automatically determines whether or not a device connected to  
a port is a powered device. PoE ports connected to network nodes that are  
not powered devices (that is, devices that receive their power from another  
power source) function as regular Ethernet ports, without PoE. The PoE  
feature remains activated on the ports but no power is delivered to the  
devices.  
PoE Standards The AT-GS900/8PS switch supports these PoE standards:  
PoE (IEEE 802.3af): This standard provides up to 15.4 watts at the  
switch port to support powered devices that require up to 12.95  
watts.  
PoE+ (IEEE 802.3at): This standard provides up to 30.0 watts at  
the switch port to support powered devices that require up to 25.5  
watts.  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Chapter 1: Overview  
PoE Powered Powered devices are grouped into the five classes listed in Table 6. The  
classes are based on the amount of power the devices require. The  
switches support all five classes.  
Device Classes  
Table 6. IEEE Powered Device Classes  
Maximum Power  
Class  
Output from a Switch  
Port  
PD Power Range  
0
1
2
3
4
15.4W  
4.0W  
0.44W to 12.95W  
0.44W to 3.84W  
3.84W to 6.49W  
6.49W to 12.95W  
12.95W to 25.5W  
7.0W  
15.4W  
30.0W  
PoE Power The AT-GS900/8PS switch has a power budget of 75 watts. This is the  
maximum amount of power the switch can provide at one time to the  
powered devices.  
Budget  
The sum of the power requirements of each of the PoE devices connected  
to the switch determines the maximum number of devices that the switch  
can support at one time. So long as the total power requirements of the  
powered devices is less than the power budget of the switch, the switch  
can supply power to all of the devices. But if the total power requirements  
exceed the power budget, the switch denies power to one or more ports  
using a mechanism referred to as port prioritization.  
To determine whether the power requirements of the PoE devices you  
plan to connect to the switch exceed its power budget, refer to the  
documentation for the power requirement of each device and add the  
requirements together. The switch should be able to power all of the  
devices simultaneously as long as the total is below its power budget. If  
the total exceeds the available power budget, you should consider  
reducing the number of PoE devices so that all of the devices receive  
power. Otherwise, the switch powers a subset of the devices, based on  
port prioritization.  
The switch can handle different power requirements on different ports.  
This enables you to connect different classes of PoE equipment to the  
PoE ports on the switch.  
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
AT-GS900/8PS Switch Installation Guide  
PoE Port If the power requirements of the powered devices exceed the switch’s  
power budget (75 W), the switch denies power to one or more PoE ports  
Prioritization  
based on a process called port prioritization. The port priority is based on  
the port number with the highest priority assigned to port 1 and the lowest  
priority assigned to port 4.  
For example, this occurs if your AT-GS900/8PS switch is powered off  
when you connect four powered devices to the PoE ports which require  
more than 75 W of combined power. When you turn the power on to the  
AT-GS900/8PS switch, the lowest priority PoE port(s) are denied power so  
that the total PoE power supplied does not exceed the 75 W power  
budget.  
You may use this mechanism to ensure that powered devices critical to  
the operations of your network are given preferential treatment by the  
switch. in the distribution of PoE power Should the demands of the devices  
exceed the available capacity of the switch, in the distribution of PoE  
power will go to those devices connected to the highest priority ports.  
PoE Guard Band The PoE Guard Band is defined as the range between 70 and 75 Watts of  
the total PoE power supplied to the switch ports. This power band is  
reached when the total PoE power requirements of all of the powered  
devices connected to the switch fall into this range. It is indicated on the  
front panel when the PoE Limit LED is ON. When this condition exists, the  
switch denies PoE power to any additional powered devices that may be  
connected to the switch.  
Note  
description of the functions indicated by the PoE Limit LED.  
Exceeding PoE If a port’s POE LED is blinking, the PoE power to that port is disabled  
indicating that the PoE power budget is exceeded. This condition occurs  
for one of two reasons:  
Power Budget  
The demand for PoE power from the power device connected to  
the port is greater than 30 W. The maximum amount of power any  
port can supply by itself is 30 W. Power demands more than 30 W  
exceed the port’s ability to deliver PoE power and the PoE power  
delivered by that port is shut down.  
The total demand for PoE power on all ports is exceeding the 75 W  
maximum PoE power limit of the switch. This condition occurs  
when you connect an additional power device to a switch port and  
the switch attempts to deliver more than the maximum PoE power  
limit for the switch. When this situation occurs, the lowest priority  
port(s) is denied PoE power so that the combined PoE power  
delivered to all the power devices connected to the switch remains  
under 75 W.  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Chapter 1: Overview  
Note  
Note  
In addition, a blinking POE LED can indicate that a PoE port has a  
short circuit.  
28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
AT-GS900/8PS Switch Installation Guide  
Wiring The IEEE 802.3af standard defines two methods by which a PSE, such as  
the switch, can transmit DC power over twisted pair cables to PDs. These  
Implementation  
methods, known as Alternatives A and B, identify the wire strands the  
switch should use when sending DC power to a PD. The AT-GS900/8PS  
switch delivers power using Alternative A.  
Twisted pair cabling typically consists of eight strands. With 10Base-T and  
100Base-TX devices, the strands connected to pins 1, 2, 3, and 6 on the  
RJ-45 connectors carry the network traffic while strands connected to pins  
4, 5, 7, and 8 are unused. With 1000Base-T devices, all eight strands are  
used to carry network data.  
It takes four strands to deliver DC power to a PD. With Alternative A, the  
power is delivered on pins 1, 2, 3, and 6. With Alternative B, the power is  
provided over the strands connected to pins 4, 5, 7, and 8.  
The ports on the AT-GS900/8PS switch delivers the power using pins 1, 2,  
3, and 6, which corresponds to Alternative A in the IEEE 802.3af standard.  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Chapter 1: Overview  
Power Supply  
The switch has an internal power supply with a single AC power supply  
socket on the back panel and autoswitch AC inputs. To power the switch  
on or off, connect or disconnect the power cord provided with the switch. A  
power cord is supplied with the switch.  
Note  
For the power requirements, refer to the “Power Specifications” on  
30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Reviewing Safety Precautions  
Please review the following safety precautions before you begin to install  
the chassis or any of its components.  
Note  
The indicates that a translation of the safety statement is  
available in a PDF document titled Translated Safety Statements.  
Warning  
To prevent electric shock, do not remove the cover. No user-  
serviceable parts inside. This unit contains hazardous voltages and  
should only be opened by a trained and qualified technician. To  
avoid the possibility of electric shock, disconnect electric power to  
the product before connecting or disconnecting the cables. E1  
Warning  
Do not work on equipment or cables during periods of lightning  
activity. E2  
Warning  
Power cord is used as a disconnection device. To de-energize  
equipment, disconnect the power cord. E3  
Warning  
Class I Equipment. This equipment must be earthed. The power  
plug must be connected to a properly wired earth ground socket  
outlet. An improperly wired socket outlet could place hazardous  
voltages on accessible metal parts. E4  
Pluggable Equipment. The socket outlet shall be installed near the  
equipment and shall be easily accessible. E5  
Caution  
Air vents must not be blocked and must have free access to the  
room ambient air for cooling. E6  
32  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
AT-GS900/8PS Switch Installation Guide  
Operating Temperature. This product is designed for a maximum  
ambient temperature of 40° degrees C. E7  
All Countries: Install product in accordance with local and National  
Electrical Codes. E8  
Circuit Overloading: Consideration should be given to the  
connection of the equipment to the supply circuit and the effect that  
overloading of circuits might have on overcurrent protection and  
supply wiring. Appropriate consideration of equipment nameplate  
ratings should be used when addressing this concern. E21  
Warning  
Mounting of the equipment in the rack should be such that a  
hazardous condition is not created due to uneven mechanical  
loading. E25  
If installed in a closed or multi-unit rack assembly, the operating  
ambient temperature of the rack environment may be greater than  
the room ambient temperature. Therefore, consideration should be  
given to installing the equipment in an environment compatible with  
the manufacturer’s maximum rated ambient temperature (Tmra).   
E35  
Caution  
Installation of the equipment in a rack should be such that the  
amount of air flow required for safe operation of the equipment is not  
compromised. E36  
Warning  
Reliable earthing of rack-mounted equipment should be maintained.  
Particular attention should be given to supply connections other than  
direct connections to the branch circuits (e.g., use of power strips).  
E37  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 2: Installation  
Selecting a Site for the Switch  
Observe the following requirements when choosing a site for your switch:  
If you plan to install the switch in an equipment rack, verify that the  
rack is safely secured and will not tip over. Devices in a rack  
should be installed starting at the bottom, with the heavier devices  
near the bottom of the rack.  
If you are installing the switch on a table, verify that the table is  
level and secure.  
The power outlet for the switch should be located near the unit and  
should be easily accessible.  
The site should provide for easy access to the ports on the front of  
the switch. This will make it easier for you to connect and  
disconnect cables, as well as view the switch’s LEDs.  
Air flow around the unit and through its vents on the side and rear  
should not be restricted so that the switch can maintain adequate  
cooling.  
Do not place objects on top of the switch.  
Do not expose the switch to moisture or water.  
Ensure that the site is a dust-free environment.  
You should use dedicated power circuits or power conditioners to  
supply reliable electrical power to the network devices.  
34  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
AT-GS900/8PS Switch Installation Guide  
Unpacking the Switch  
To unpack the switch, perform the following procedure:  
1. Remove all of the components from the shipping package.  
Note  
Store the packaging material in a safe location. You must use the  
original shipping material if you need to return the unit to Allied  
Telesis.  
2. Place the switch on a level, secure surface.  
35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Chapter 2: Installation  
3. Verify that the shipping container includes the AT-GS900/8PS Switch  
and the items shown below in Figure 4.  
Two equipment brackets  
(for wall or rack  
installation)  
Eight bracket screws (for  
wall or rack installation)  
Four wall anchors (for wall  
mount installation)  
Four screws and washers  
(for wall mount installation)  
Four rubber feet (for  
desktop installation)  
One regional AC power  
cord  
One SFP slot dust cover  
(pre-installed)  
Four screws (for rack  
mount installation)  
Figure 4. AT-GS900/8PS Switch Items  
36  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
AT-GS900/8PS Switch Installation Guide  
Installing the Switch on a Desktop  
You may install the AT-GS900/8PS Switch on a desktop or in a standard  
19-inch equipment rack. To install the switch in a rack, refer to “Installing  
To place the switch on a desktop, perform the following procedure:  
1. Remove all equipment from the package and store the packaging  
material in a safe place.  
2. Turn the switch over and place it on a table.  
3. Attach the four rubber feet to the bottom of the switch as shown in  
Figure 5. Attaching the Rubber Feet  
4. Turn the switch over again and place it on a flat, secure surface (such  
as a desk or table) leaving ample space around the unit for ventilation.  
37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Chapter 2: Installation  
Installing the Switch in an Equipment Rack  
To install the switch in a standard 19-inch equipment rack, perform the  
following procedure:  
1. If the rubber feet are attached to the bottom of the switch, remove  
them using a flat-head screwdriver.  
2. Attach the two rack mount brackets to the sides of the switch using the  
eight bracket screws that are provided. There are four possible  
positions in which the brackets may be installed.  
Figure 6. Attaching the Rack-Mount Brackets to the Switch  
3. Mount the switch in a standard 19-inch equipment rack using four  
equipment rack screws provided.  
38  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
AT-GS900/8PS Switch Installation Guide  
Figure 7. Mounting the Switch in an Equipment Rack  
39  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Chapter 2: Installation  
Installing the Switch on a Wall  
To install the switch on a wall, perform the following procedure:  
1. Turn the switch over and place it on a table.  
2. If the rubber feet are attached to the bottom of the switch, remove  
them using a flat-head screwdriver.  
3. Orient the brackets against the sides of the switch as shown in  
Figure 8, and secure them to the unit with the eight bracket screws  
included with the switch.  
Figure 8. Attaching the Brackets to Install the Switch on a Wall  
4. Have another person hold the switch at the wall location where the  
switch is to be installed, while you use a pencil or pen to mark the wall  
with the locations of the four holes in the brackets. The switch should  
be oriented such that its front faceplate is facing up and is level to the  
40  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
AT-GS900/8PS Switch Installation Guide  
Figure 9. Marking the Screw Hole Locations  
5. Install the four plastic anchors included with the switch into the wall, at  
the locations marked in the previous step. The anchors require 0.635  
mm (0.25 in.) holes.  
6. While another person holds the switch at the wall location, secure it to  
the wall using the four wall mount screws and washers that are  
41  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Chapter 2: Installation  
Figure 10. Securing the Switch to the Wall  
42  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
AT-GS900/8PS Switch Installation Guide  
Installing Optional SFP Transceiver  
To install an SFP transceiver, perform the following procedure:  
Note  
You should always install the transceiver before connecting the fiber  
optic cables to it.  
Note  
The transceiver can be hot-swapped; you do not need to power off  
the switch to install a transceiver. However, always remove the  
cables from the transceiver before removing it.  
1. Remove the transceiver from its shipping container and store the  
packaging material in a safe location.  
Warning  
An SFP transceiver can be damaged by static electricity. Be sure to  
observe all standard electrostatic discharge (ESD) precautions,  
such as wearing an antistatic wrist strap, to avoid damaging the  
transceiver.  
2. Remove the dust plug from an SFP slot. See Figure 11.  
Figure 11. Removing the Dust Plug from an SFP Slot  
3. Position the SFP transceiver with the label facing up.  
43  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Chapter 2: Installation  
4. With the handle on the transceiver oriented towards the top of the  
switch, slide the transceiver into the SFP slot until it clicks into place.  
Figure 12. Inserting the SFP  
5. Verify that the handle on the transceiver is in the upright position or  
oriented towards the top of the switch. This secures the transceiver  
and prevents it from being dislodged from the slot.  
Note  
SFP transceivers are dust sensitive. Always keep the protective plug  
in the optical bore when a fiber optic cable is not installed, or when  
storing the SFP. When you do remove the plug, keep it for future  
use.  
Note  
Unnecessary removal and insertion of an SFP can lead to  
premature failure.  
For information on the cable specifications of the SFP, consult the  
documentation shipped with the SFP.  
44  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
AT-GS900/8PS Switch Installation Guide  
Cabling the Switch  
Observe the following guidelines when connecting twisted pair and fiber  
optic cables to the ports on the switch:  
The cable specifications for the twisted pair ports are given in  
Refer to the cable specifications are included in the SFP module  
data sheet for the SFP module installed.  
The cable connector should fit snugly into the port on the switch.  
The tab on the connector should lock the connector into place.  
Because the twisted pair ports have auto-MDI/MDI-X, you may use  
straight-through or cross-over twisted pair cables to connect any  
type of Ethernet network devices to the switch.  
The default speed and duplex settings for the ports are determined  
with Auto-Negotiation. The end-nodes connected to the twisted-  
pair ports should be configured for Auto-Negotiation to insure that  
both the speed and duplex modes are matched on each end.  
45  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Chapter 2: Installation  
Powering On the Switch  
To power on the switch, perform the following procedure:  
1. Plug the power cord into the AC power connector on the back of the  
switch, as shown in Figure 13.  
Figure 13. Plugging in the AC Power Cord  
2. Plug the other end of the power cord into a wall outlet.  
Warning: Power cord is used as a disconnection device. To de-  
energize equipment, disconnect the power cord. E3  
Pluggable Equipment. The socket outlet shall be installed near  
the equipment and shall be easily accessible. E5  
3. Verify that the POWER LED is green. If the LED is OFF, refer to  
The switch is now powered on and ready for network operations.  
46  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
AT-GS900/8PS Switch Installation Guide  
Chapter 3  
Troubleshooting  
This chapter contains information on how to troubleshoot the switch if a  
problem occurs. The following problems are addressed:  
Note  
For further assistance, please contact Allied Telesis Technical  
Power LED OFF  
Problem: The POWER LED on the front of the switch is off.  
Solutions: The unit is not receiving power. Try the following:  
Verify that the power cord is securely connected to the power  
source and to the AC connector on the back panel of the switch.  
Verify that the power outlet has power by connecting another  
device to it.  
Try connecting the unit to another power source.  
Try a different power cord.  
Verify that the voltage from the power source is within the required  
levels for your region.  
Twisted Pair Port LINK/ACT LED Off  
Problem: A twisted pair port on the switch is connected to a network  
device but the port’s LINK/ACT LED is off.  
Solutions: The port is unable to establish a link to a network device. Try  
47  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
Chapter 3: Troubleshooting  
the following:  
Verify that the network device connected to the twisted pair port is  
powered on and is operating properly.  
Verify that the twisted pair cable is securely connected to the  
switch port and to the port on the remote network device.  
Verify that the port is connected to the correct twisted pair cable.  
This is to eliminate the possibility that the port is connected to the  
wrong network device, such as a powered off device.  
Try connecting another network device to the twisted pair port with  
a different cable. If the twisted pair port is able to establish a link,  
then the problem is with the cable or the other network device.  
Verify that the twisted pair cable does not exceed 100 meters (328  
feet).  
Verify that you are using the appropriate category of twisted pair  
cable: Category 3 or better for 10 Mbps operation and Category 5  
and Category 5E for 100 and 1000 Mbps operation.  
Note  
A 1000Base connection may require five to ten seconds to establish  
a link.  
SFP Port LINK/ACT LED Off  
Problem: The LINK/ACT LED for an SFP transceiver is off.  
Solutions: The fiber optic port on the transceiver is unable to establish a  
link to a network device. Try the following:  
Verify that the network device connected to the fiber optic port is  
operating properly.  
Verify that the fiber optic cable is securely connected to the port on  
the media converter channel and to the port on the remote network  
device.  
Check that the SFP module is fully inserted in the slot.  
Verify that the operating specifications of the fiber optic ports on  
the SFP transceiver and the remote network device are  
compatible.  
Verify that the correct type of fiber optic cabling is being used.  
Verify that the port is connected to the correct fiber optic cable.  
This is to eliminate the possibility that the port is connected to the  
wrong remote network device, such as a powered off device.  
Try connecting another network device to the fiber optic port using  
48  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
AT-GS900/8PS Switch Installation Guide  
a different cable. If the port is able to establish a link, then the  
problem is with the cable or with the other network device.  
If the remote network device is a managed device, use its  
management firmware to determine whether its port is enabled.  
Test the attenuation on the fiber optic cable with a fiber optic tester  
to determine whether the optical signal is too weak (sensitivity) or  
too strong (maximum input power).  
Slow Network Performance  
Problem: Network performance between a twisted pair port on the switch  
and a network device is slow.  
Solution: There might be a duplex mode mismatch between the port and  
the network device. Since the AT-GS900/8PS copper ports are always  
configured for Auto-Negotiation, they will default to half duplex mode if the  
corresponding link partner is configured for a fixed duplex mode. This may  
slow the transfer of Ethernet traffic. If this is the cause of the problem,  
adjust the duplex mode of the port on the network device to Auto-  
Negotiation so they can agree on the same duplex mode.  
LINK/ACT LED Intermittently Blinking  
Problem: A port’s LINK/ACT LED is intermittently blinking.  
Solutions: The link between the port and the network device is  
intermittent. Try the following:  
Connect another network device with a different cable to the port. If  
the Link LED remains steady on, then the problem is with the  
original cable or the network device.  
If the problem is with an SFP transceiver, check that the  
transceiver is fully inserted in the slot.  
49  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Chapter 3: Troubleshooting  
Powered Device Not Receiving Power  
Problem: Port’s PoE LED is OFF  
Solutions: If a powered device (PD) is not receiving power from the  
AT-GS900/8PS switch and the port’s PoE LED is off, do the following:  
Verify that the AT-GS900/8PS is has AC power and the Power  
LED is on.  
Verify that the port’s link L/A LED is either solid or blinking green. If  
the L/A LED is off, do the following:  
-
Check the Ethernet connections between the AT-GS900/8PS  
port and the powered device.  
-
For legacy PDs, check to be sure that it is designed to receive  
power over pins 1, 2, 3, and 6 on the RJ-45 port. This can be  
verified by reviewing the device’s documentation or data sheet.  
If it is not capable of receiving power on these pairs, it is  
incompatible with the AT-GS900/8PS.  
Note  
For an explanation of the PoE Guard Band, see “PoE Port  
Problem: Port POE Status LED is Blinking  
If the Port PoE Status LED is blinking, it indicates one of the following  
problems:  
There may be a short circuit in the Ethernet cable. You can verify  
that the Ethernet cable does not have a short by replacing it with a  
cable that you know is good. If the problem is resolved with the  
good cable, then the original cable has a fault.  
The power demand of the PD may be overloading the port. Check  
that the device’s power requirements does not exceed 30 W. This  
can be verified by reviewing the device’s documentation or data  
sheet. The demand for PoE power from the power device  
connected to the port is greater than 30 W. The maximum amount  
of power any port can supply by itself is 30 W. More than 30 W  
exceeds the port’s ability to deliver PoE power.  
The total demand for PoE power on all ports is exceeding the 75 W  
maximum PoE power limit of the switch. This condition occurs  
when you connect an additional power device to a switch port and  
the switch attempts to deliver more than the maximum PoE power  
limit for the switch. When this situation occurs, the lowest priority  
port(s) is denied PoE power so the combined PoE power delivered  
to all of the power devices remains under 75 W.  
50  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
AT-GS900/8PS Switch Installation Guide  
Resetting Blinking PoE Port LED  
To reset a blinking PoE port LED, perform the following steps:  
1. Turn the switch power off by disconnecting the AC power cord.  
2. If the total PoE power from all the powered devices connected to the  
switch is greater than 70 W, reduce the total PoE load until it is less  
than 70 W.  
3. If a powered device connected to a specific port requires more than 30  
W, disconnect it from the switch.  
4. Turn on the switch by re-connecting the AC power cord.  
51  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Chapter 3: Troubleshooting  
52  
Download from Www.Somanuals.com. All Manuals Search And Download.  
AT-GS900/8PS Switch Installation Guide  
Appendix A  
Technical Specifications  
The following specifications are for the AT-GS950/8 Gigabit Ethernet PoE  
switch.  
Physical Specifications  
Table 7. Physical Specifications  
Dimensions (H x W x D)  
280 mm x 180 mm x 44 mm  
(11.0 in x 7.1 in x 1.7 in)  
Weight  
1.52 kg (3.35 lbs)  
Environmental Specifications  
Table 8. Environmental Specifications  
Operating Temperature 0° C to 40° C (32° F to 113° F)  
Storage Temperature  
Operating Humidity  
Storage Humidity  
-25° C to 70° C (-13° F to 158° F)  
5% to 90% non-condensing  
5% to 95% non-condensing  
Up to 3,000 m (9,843 ft)  
Operating Altitude  
Range  
Power Specifications  
Table 9. Power Specifications  
Input Supply Voltage  
Rated Input Current  
AT-GS900/8PS:  
100-240 VAC, 50 - 60 Hz  
1.7 A  
125.5 W  
53  
Download from Www.Somanuals.com. All Manuals Search And Download.  
                 
Appendix A: Technical Specifications  
PoE Specifications  
Table 10. PoE Specifications  
Ports  
Ports 1, 2, 3, 4  
Port Priority:  
Standard  
Mode  
Port 1 (Highest) and Port 4 (Lowest)  
Supports both IEEE 802.3at and IEEE 802.3af  
Alternate A  
Max Power Limit per port 30W  
Max Power Limit  
PoE Guard Band  
75W  
70W to 75 W  
Note  
For an explanation of these PoE specifications, see “Power Over  
Safety and Electromagnetic Emissions Certifications  
Table 11. Safety and Electromagnetic Emissions Certifications  
FCC Part 15 Class A  
RFI Emissions  
ISPR 22 Class A,  
EN55022:2006/A:2007 Class A  
Immunity  
EN55024  
Electrical Safety  
EN60950 (TUV) T-Mark, UL 60950  
(CULUS), C-TICK, CE  
EU-RoHS compliant  
Environmental Compliance WEEE  
China RoHS compliant  
Quality and Reliability  
(MTBF)  
800,000 Hours  
54  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
AT-GS900/8PS Switch Installation Guide  
Connectors and Port Pinouts  
This section lists the connectors and connector pinouts.  
Figure 14 illustrates the pin layout for an RJ-45 connector and port.  
Figure 14. RJ-45 Connector and Port Pin Layout  
Table 12 lists the RJ-45 pin signals when a twisted pair port is operating in  
the MDI configuration.  
Table 12. MDI Pin Signals (10Base-T or 100Base-TX)  
Pin  
Signal  
1
2
3
6
TX+  
TX-  
RX+  
RX-  
Table 13 lists the RJ-45 port pin signals when a twisted pair port is  
operating in the MDI-X configuration.  
Table 13. MDI-X Pin Signals (10Base-T or 100Base-TX)  
Pin  
Signal  
1
2
3
6
RX+  
RX-  
TX+  
TX-  
55  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
Appendix A: Technical Specifications  
Table 14 lists the RJ-45 connector pins and their signals when a  
1000Base-T port is operating at 1000 Mbps.  
Table 14. RJ-45 1000Base-T Connector Pinouts  
Pin  
Pair  
Signal  
1
2
3
4
5
6
7
8
1
1
2
3
3
2
4
4
TX and RX+  
TX and RX-  
TX and RX+  
TX and RX+  
TX and RX-  
TX and RX-  
TX and RX+  
TX and RX-  
56  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 

Aastra Telecom Telephone 57i IP Phone User Manual
Aastra Telecom Telephone M5316 User Manual
Acoustic Research Universal Remote ARRX15G User Manual
Adder Technology Network Card AVX4016 User Manual
Alice Law Telephone ATS 4121CL User Manual
Alliance Laundry Systems Washer Dryer CPD6C User Manual
Alpine Car Amplifier MRV F307 User Manual
American DJ Indoor Furnishings Sparkle User Manual
BB Electronics Network Card 3PXCC1A User Manual
Behringer Home Theater System PX3000 User Manual