Chapter 1  
Introduction  
Introducing the AT-8800 Series Switch  
Congratulations on purchasing an AT-8800 Series Intelligent Workgroup  
Switch. The AT-8800 Series Switch has been developed to meet the  
exceptionally high performance demands of low to mid-range applications and  
deliver low-latency high-bandwidth wirespeed Layer 2 and 3 switching.  
This guide introduces the AT-8800 Series Switch and will guide you through  
the most common uses and applications of your new switch. Getting started  
will not take long—many applications are set up in just a few minutes. If you  
have any questions about the switch, contact your authorised distributor or  
reseller.  
Your AT-8800 Series Switch is supplied with default settings which enable it to  
operate as a Layer 2 switch immediately, without any configuration. Even if  
this is all you want to do, you should still gain access to the switch  
configuration, if only to change the manager password to prevent unauthorised  
access.  
To change the switching configuration, and to take advantage of the advanced  
routing features, you will need to enter detailed configuration. The switch has  
both a Command Line Interface (CLI) and a Graphical User Interface (GUI) for  
configuration and management. Before you can use the GUI, you will need to  
login to the switch and use its CLI to allocate an IP address to at least one  
interface.  
Why Read this User Guide?  
Before you use your switch in a live network, please read this guide. The guide  
tells you how to access and use the Command Line Interface (CLI) and  
Graphical User Interface (GUI) to configure the switch software. It then  
introduces a number of common switch functions and how to configure them  
using the CLI. For more detailed descriptions of all commands, display  
outputs, and background information, see the Software Reference. For  
information on configuration using the GUI, see the context-sensitive online  
GUI help.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
8
AT-8800 Series Switch User Guide  
This user guide is organised into the following chapters:  
Chapter 1, Introduction gives an overview of the switch features and of the  
documentation supplied with your switch.  
how to gain access to the command lineinterface.  
how to access and use the graphical user interface, including  
troubleshooting the GUI.  
Chapter 4, Operating the switch introduces general operation, management  
and support features, including loading and installing support files and  
new releases.  
Chapter 5, Layer 2 Switching describes how to configure Layer 2 switching  
features, including switch ports and VLANs.  
Chapter 6, Layer 3 outlines some of the switch’s Layer 3 features, including  
IP, IP multicasting, IPX and Appletalk.  
Chapter 7, Maintenance and Troubleshooting describes some of the commands  
you can use to monitor the switch and diagnose faults.  
Where To Find More Information  
Before installing the switch and any expansion options, read the important  
safety information in the AT-8800 Series Switch Safety and Statutory Information  
booklet.  
Follow the Quick Install Guide’s step-by-step instructions for physically  
installing the switch.  
The AT-8800 Series Switch Hardware Reference gives detailed information about  
the equipment hardware.  
The context-sensitive online GUI help gives descriptions of each page and  
element of the GUI.  
Once you are familiar with the basic operations of the switch, use the AT-8800  
Series Switch Software Reference for full descriptions of routing features and  
command syntax.  
The AT-8800 Series Switch Documentation Set  
The documentation set for the AT-8800 Series Switch includes:  
AT-8800 Series Switch Safety and Statutory Information  
AT-8800 Series Switch Quick Install Guide  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Introduction  
9
AT-8800 Series Switch Documentation and Tools CD-ROM  
The AT-8800 Series Switch Documentation Set in Adobe Acrobat PDF  
format is bundled with every switch—the complete reference to installing,  
configuring and managing the switch, including detailed descriptions of all  
commands.  
The CD-ROM includes the following PDF documents:  
AT-8800 Series Switch Safety and Statutory Information  
AT-8800 Series Switch Quick Install Guide  
AT-8800 Series Switch Hardware Reference  
AT-8800 Series Switch Software Reference  
The CD-ROM also includes:  
AT-TFTP Server for Windows, for downloading software releases,  
scripts and other files to or from an AT8800 switch.  
Adobe Acrobat Reader for Windows for viewing and printing the  
online documentation in PDF format. Get instant access to information  
with full-text searching of PDF documents by keyword or phrase.  
Microsoft Internet Explorer.  
A demonstration version of F-Secure’s Secure Shell client for Windows.  
Information about other Allied Telesyn routing and switching  
products.  
Online Technical Support  
For online support for your AT-8800 Series Switch, see our online support page  
This page also contains the latest switch software releases, patches and GUI  
resource files. Use the LOAD command to download software upgrades  
directly from the Allied Telesyn web site to the router’s FLASH memory. Use  
the SET INSTALL command to enable the new software (see “Upgrading Switch  
Software” on page 56 for detailed instructions).  
If you require further assistance, contact your authorised distributor or reseller.  
Features of the AT-8800 Series Switch  
There are two models in the AT-8800 Series, which provide either 48 or 24  
10/100 TX Fast Ethernet ports. Both models also feature:  
• 2 GBIC uplink ports  
• Single PSU and redundant PSU (RPS)  
PAC interface connection  
The software support provides wirespeed Layer 2 switching, including  
support for Virtual LANs, and wirespeed Layer 3 switching of IP and IP  
multicasting packets. In addition, the switch provides a wide array of  
multiprotocol routing, security and network management features.  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
10  
AT-8800 Series Switch User Guide  
Management Features  
The following features enhance management of the switch:  
A sophisticated and configurable event logging facility for monitoring and  
alarm notification to single or multiple management centres.  
Triggers for automatic and timed execution of commands in response to  
events.  
Scripting for automated configuration and centralised management of  
configurations.  
Dynamic Host Configuration Protocol (DHCP) for IP and IPv6. DHCP lets  
you automatically assign IP addresses and other configuration information  
to PCs and other hosts on TCP/IP networks.  
Support for the Simple Network Management Protocol (SNMP), standard  
MIBs and the Allied Telesyn Enterprise MIB, enabling the switch to be  
managed by a separate SNMP management station.  
Telnet client and server.  
Secure Shell remote management.  
An HTTP client that allows the direct download of files from a web server  
to the router’s FLASH memory.  
For complete descriptions of these software features, see the AT-8800 Series  
Switch Software Reference.  
Software Features  
AT-8800 Series Intelligent Workgroup Switches provide efficient and cost-  
effective multiprotocol routing, terminal serving and integrated network  
management over wide area networks and LANs. All models can run the same  
software suite and can provide all of the following functions simultaneously  
(depending on the hardware configuration):  
Wide area networking via Point-to-Point Protocol.  
TCP/IP routing.  
Novell® IPX routing.  
AppleTalk routing.  
Generic Routing Encapsulation (GRE) protocols.  
IP multicast routing support, including Internet Group Management  
Protocol (IGMP), Distance Vector Multicast Routing Protocol (DVMRP)  
and Protocol Independent Multicast (PIM) Sparse and Dense Modes.  
Ping Polling for determining device reachability and responding when a  
device or link goes up or down.  
IPv6 routing support, including stateless address autoconfiguration, RIPv6  
and ICMPv6.  
IPv6 multicast routing support, including Multicast Listener Discovery  
(MLDv2) and Protocol Independent Multicast (PIM) Sparse and Dense  
Modes.  
OSPF, RIP (IP and Novell®), SAP (Novell®), EGP and BGP routing  
protocols.  
ARP, Proxy ARP and Inverse ARP address resolution protocols.  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Introduction  
11  
Sophisticated packet filtering.  
Bridging.  
Van Jacobson’s header compression, STAC LZS and Predictor compression,  
and DES encryption.  
Terminal serving using Telnet, with local host nicknames.  
Access to network printers via LPD or TCP streams.  
Resource Reservation Protocol (RSVP) for delivering quality of service to  
application data streams.  
A fully featured, stateful inspection firewall.  
IPsec-compliant IP security services.  
Integration with a Public Key Infrastructure (PKI).  
Virtual Router Redundancy Protocol (VRRP).  
Border Gateway Protocol version 4 (BGP-4).  
Load Balancing for distributing traffic among multiple resources.  
Software Secure Sockets Layer (SSL).  
802.1x port authentication.  
Special Feature Licences  
You need a special feature licence and password to activate some special  
features over and above the standard software release. Typically, these special  
features are covered by government security regulations. Special feature  
licences and passwords are quite separate and distinct from the standard  
software release licences and passwords. Some of the software features that  
require a special feature licence are:  
Triple DES S/W  
Firewall SW  
Firewall SMTP Application Gateway  
Firewall HTTP Application Gateway  
DES encryption  
IPv6  
IP Multicast routing: DVMRP and PIM-Sparse Mode  
IPX routing  
IPX/SPX Spoofing  
IPX Filtering (not between switch ports)  
AppleTalk  
BGP-4  
Load balancer  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
12  
AT-8800 Series Switch User Guide  
Most software features that require a special feature licence are bundled into  
one of the following special feature licence packs:  
Full Layer 3 Feature Licence  
Advanced Layer 3 Feature Licence  
Security Pack Feature Licence  
For more information about purchasing special feature licences, contact your  
Allied Telesyn authorised distributor or reseller. For information on how to  
enable special feature licences using the CLI, see Enabling Special Feature  
Warning about FLASH memory  
Before you start to configure your switch, note that it is possible to enter  
commands that can impact severely on your router’s performance.  
DO NOT clear the FLASH memory completely. The software release files are  
stored in FLASH, and clearing FLASH memory would leave no software to run  
the switch.  
While FLASH is compacting, do not restart the switch or use any commands  
that affect the FLASH file subsystem. Do not restart the switch, or create, edit,  
load, rename or delete any files until a message confirms that FLASH file  
compaction is completed. Interrupting flash compaction may result in damage  
to files. Damaged files are likely to prevent the switch from operating correctly.  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Chapter 2  
Getting Started with the Command Line  
Interface (CLI)  
This Chapter  
This chapter describes how to access the switch’s CLI, and provides basic  
information about configuring the switch, including how to:  
Physically connect a terminal or PC to the switch (see “Connecting a  
Terminal or PC” on page 14 and the Quick Install Guide).  
Set the Terminal Communication parameters to match the router’s settings  
Log in to the switch as a manager (see “Logging In” on page 15).  
Configure IP addresses on the switch interfaces over which you will  
manage the switch. This is necessary if you will access the switch using the  
Change the management password to limit unauthorised access to the  
switch configuration (see Changing a Password” on page 17).  
Use the command line interface to control the switch software, including  
creating aliases for often used character sequences (see Using the  
Set the online help file to gain access to command syntax help (see Getting  
Enable any special feature licences (see Enabling Special Feature Licences”  
Set the name, location and contact details for the switch (see Setting  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
14  
AT-8800 Series Switch User Guide  
Connecting a Terminal or PC  
The first thing to do after physically installing the switch is to start a terminal  
or terminal emulation session to access the switch. Then you can use the  
command line interface (CLI) to configure the switch. If you wish to configure  
the switch using the Graphical User Interface, you must first access the CLI and  
assign an IP address to at least one interface.  
You can use a PC running terminal emulation software as the manager console  
instead of a terminal. Many terminal emulation applications are available for  
the PC, but the most readily available is the HyperTerminal application  
included in Microsoft® Windows™ 95, Windows™ 98, and Windows™ 2000.  
In a normal Windows™ installation HyperTerminal is located in the  
Accessories group. In Windows™ 2000, HyperTerminal is located in the Start >  
Programs > Accessories > Communications menu.  
The key to successfully using terminal emulation software with the switch is to  
configure the communications parameters in the terminal emulation software  
to match the default settings of the console port on the switch. For instructions  
on how to configure HyperTerminal, see the AT-8800 Series Switch Hardware  
Reference.  
To start a terminal session, connect to the switch in one of the following ways:  
Connect a VT100-compatible terminal to the RS-232 Terminal Port (asyn0),  
set the communications parameters on the terminal (Table 1 on page 14),  
and press [Enter] a few times until the router’s login prompt appears  
OR  
Connect the COM port of a PC running terminal emulation software such  
as Windows Terminal or HyperTerminal to the RS-232 Terminal Port  
(asyn0), set the communications parameters on the terminal emulation  
software (Table 1 on page 14), and press [Enter] a few times until the  
router’s login prompt appears.  
Terminal Communication Parameters  
Check that the terminal or modem’s communication settings match the settings  
of the asynchronous port. By default, the asynchronous port (also known as the  
Console, RS-232, or Config port) on the switch is set to the parameters shown  
Table 1: Parameters for terminal communication  
Parameter  
Baud rate  
Data bits  
Parity  
Value  
9600  
8
None  
1
Stop bits  
Flow control  
Hardware  
Refer to the user manual supplied with the terminal or modem for details of  
how to change the communications settings for the terminal or modem.  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Getting Started with the Command Line Interface (CLI)  
15  
If a modem is connected, configure the switch to make and/or accept calls via  
the modem. To set the CDCONTROL parameter to “CONNECT” and the  
FLOW parameter to “HARDWARE”, enter the command:  
SET ASYN CDCONTROL=CONNECT FLOW=HARDWARE  
If the terminal or modem is used with communications settings other than the  
default settings, then configure the asynchronous port to match the terminal or  
modem settings using the SET ASYN command.  
See the router’s online help or the Interfaces chapter in the AT-8800 Series Switch  
Software Reference for more information on how to configure the asynchronous  
port.  
Logging In  
When you access the switch from a terminal or PC connected to the RS-232  
terminal port (asyn0), or via a Telnet or HTTP connection, you must enter a  
login name and password to gain access to the command prompt. When the  
switch is supplied, it has a manager account with an initial password friend.  
Enter your login name at the login prompt:  
login: manager  
Enter the password at the password prompt:  
password: friend  
After you log into the manager account you can enter commands from this  
document and from the AT-8800 Series Switch Software Reference.  
Assigning an IP Address  
To configure the switch to perform IP routing (for example, to access the  
Internet) you need to configure IP. You also need to configure IP if you want to  
manage the switch from a Telnet session or with the GUI. For detailed  
instructions on accessing the switch with the GUI, see “Establishing a  
First enable IP, using the command:  
ENABLE IP  
Then, add an IP address to each of the switch interfaces that you want to  
process IP traffic (for example, the default VLAN (vlan1)).  
For the default VLAN, use the command:  
ADD IP INTERFACE=vlan1 IPADDRESS=ipadd MASK=mask  
where:  
ipadd is an unused IP address on your LAN.  
mask is the subnet mask (for example 255.255.255.0)  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
16  
AT-8800 Series Switch User Guide  
If IP addresses on your LAN are assigned dynamically by DHCP, you can set  
the switch to request an IP address from the DHCP server, using the  
commands:  
ADD IP INTERFACE=vlan1 IPADDRESS=DHCP  
ENABLE IP REMOTEASSIGN  
You do not need to set the MASK parameter because the subnet mask received  
from the DHCP server is used.  
If you use DHCP to assign IP addresses to devices on your LAN, and you want to  
manage the switch within this DHCP regime, it is recommended that you set your  
DHCP server to always assign the same IP address to the switch. This will enable you  
to access the GUI by browsing to that IP address, and will also let you use the switch as  
a gateway device for your LAN. If you need the switch's MAC address for this, it can be  
displayed using the command SHOW SWITCH.  
To change the IP address for an interface, enter the command:  
SET IP INTERFACE=interface IPADDRESS=ipadd MASK=ipadd  
When you are configuring the switch remotely, if you change the configuration (for  
example, the VLAN membership) of the port over which you are configuring, the switch  
is likely to break the connection.  
For more information about switch ports and Virtual LANs (VLANs), see  
Chapter 5, Layer 2 Switching in this document, and the Switching chapter in the  
AT-8800 Series Switch Software Reference. For more information about IP  
addressing and routing, see Chapter 6, Layer 3 in this document, and the Internet  
Protocol (IP) chapter in the AT-8800 Series Switch Software Reference.  
Setting Routes  
The process of routing packets consists of selectively forwarding data packets  
from one network to another. Your switch makes a decision to send a packet to  
a particular network on information it learns dynamically from listening to the  
selected route protocol and on the static information entered as part of the  
configuration process. In addition, you can configure user-defined filters to  
restrict the way packets are sent.  
Your switch maintains a table of routes which holds information about routes  
to destinations. The route table tells the switch how to find a remote network or  
host. A route is uniquely identified by IP address, network mask, next hop,  
ifIndex, protocol and policy. A list of routes comprises all the different routes to  
a destination. The routes may have different metrics, next hops, policy or  
protocol. A list of routes is uniquely identified by its IP address and net mask.  
The routing table is maintained dynamically by using one or more routing  
protocols such as RIP, EGP and OSPF. These act to exchange routing  
information with other switches or hosts.  
You can also add static routes to the route table to define default routes to  
external switches or networks and to define subnets.  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Getting Started with the Command Line Interface (CLI)  
17  
To add a static route, enter the command:  
ADD IP ROUTE=ipadd INTERFACE=interface NEXTHOP=ipadd  
[CIRCUIT=miox-circuit] [DLCI=dlci]  
[MASK=ipadd][METRIC=1..16] [METRIC1=1..16]  
[METRIC2=1..65535][POLICY=0..7] [PREFERENCE=0..65535]  
To displays the entire routing table, including both static and dynamic routes,  
enter the command:  
SHOW IP ROUTE  
For more information about setting IP routes, see the Internet Protocol (IP)  
chapter in the AT-8800 Series Switch Software Reference.  
Changing a Password  
You should change this password to prevent unauthorised access to the switch.  
Enter the command:  
SET PASSWORD  
The switch prompts you for the current password, for the new password, and  
for confirmation of the new password. The password can contain any printable  
characters, and must be at least a minimum length, by default six characters.  
(To change the default minimum length, see the SET USER command in the  
Operations chapter, AT-8800 Series Switch Software Reference.)  
Choosing a Password  
All users, including managers, should take care in selecting passwords. Tools  
exist that enable hackers to guess or test many combinations of login names  
and passwords easily. The User Authentication Facility (UAF) provides some  
protection against such attacks by allowing the manager to set the number of  
consecutive login failures allowed and a lockout period when the limit is  
exceeded.  
However, the best protection against password discovery is to select a good  
password and keep it secret. When choosing a password:  
Do make it six or more characters in length. The UAF enforces a minimum  
password length, which the manager can change. The default is six  
characters.  
Do include both alphabetic (a–z) and numeric (0–9) characters.  
Do include both uppercase and lowercase characters. The passwords  
stored by the switch are case-sensitive, so “bgz4kal” and “Bgz4Kal” are  
different.  
Do avoid words found in a dictionary, unless combined with other random  
alphabetic and numeric characters.  
Do not use the login name, or the word “password” as the password.  
Do not use your name, your mother’s name, your spouse’s name, your  
pet’s name, or the name of your favourite cologne, actor, food or song.  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
18  
AT-8800 Series Switch User Guide  
Do not use your birth date, street number or telephone number.  
Do not write down your password anywhere.  
Make sure you remember the new password created as you cannot retrieve a  
lost password. Recovery of access to the switch is complex.  
Once you have logged into the manager account you are able to enter  
commands from this guide and from the AT-8800 Series Switch Software  
Reference.  
Using the Commands  
You control the switch with commands described in this document and in the  
AT-8800 Series Switch Software Reference. While the keywords in commands are  
not case sensitive, the values entered for some parameters are (especially  
passwords). The switch supports command line editing and recall. Command  
line editing functions and keystrokes are shown in Table 2 on page 18.  
Table 2: Command line editing functions and keystrokes .  
Function  
VT100 Terminal  
Dumb terminal  
Not available  
[Delete] or [Backspace]  
Not available  
[Ctrl/U]  
Move cursor within command line , →  
Delete character to left of cursor  
Toggle between insert/overstrike  
Clear command line  
[Delete] or [Backspace]  
[Ctrl/O]  
[Ctrl/U]  
Recall previous command  
Recall next command  
or [Ctrl/B]  
or [Ctrl/F]  
[Ctrl/B]  
[Ctrl/F]  
Display command history  
[Ctrl/C] or  
[Ctrl/C]  
SHOW PORT HISTORY  
or SHOW PORT HISTORY  
Clear command history  
RESET PORT HISTORY  
[Tab] or [Ctrl/I]  
RESET PORT HISTORY  
[Tab] or [Ctrl/I]  
Recall matching command  
The switch assumes that the width of the terminal screen is 80 characters, and  
performs command line wrapping at the 80th column regardless of the setting  
of the terminal. To execute a command the cursor does not need to be at the  
end of the line. The default editing mode is insert mode. Characters are  
inserted at the cursor position and any characters to the right of the cursor are  
pushed to the right to make room. In overstrike mode, characters are inserted  
at the cursor position and replace any existing characters.  
Commands are limited to 1000 characters, excluding the prompt. Pathnames of  
up to 256 characters, including file names, and file names up to 16 characters  
long, with extensions of 3 characters, are supported.  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Getting Started with the Command Line Interface (CLI)  
19  
Aliases  
The command line interface supports aliases. An alias is a short name for an  
often-used longer character sequence. When the user presses [Enter] to execute  
the command line, the command processor first checks the command line for  
aliases and substitutes the replacement text. The command line is then parsed  
and processed normally. Alias substitution is not recursive—the command line  
is scanned only once for aliases.  
Aliases are created and destroyed using the commands:  
ADD ALIAS=name STRING=substitution  
DELETE ALIAS=name  
Getting Command Line Help  
Online help is available for all switch commands. A multilingual, language-  
independent online help facility provides help information via the command:  
HELP [topic]  
If a topic is not specified, a list of available topics is displayed. The HELP  
command displays information from the system help file stored in FLASH  
memory. The help file uses a simple mark-up language to identify topics,  
access level (USER or MANAGER) and help text. Both standard ASCII and  
Unicode character encodings are supported. Alternate help files can be  
uploaded and stored in FLASH, then activated using the command:  
SET HELP=helpfile  
To display the current help file, enter the command:  
SHOW SYSTEM  
The help file is easily modified, for example to provide detailed site-specific  
support information. The mark-up language specification and preprocessor  
program are available from your authorised distributor or reseller.  
Also, typing a question mark “?” at the end of a partially completed command  
displays a list of the parameters that may follow the current command line,  
with the minimum abbreviations in uppercase letters (see Figure 1). The  
current command line is then re-displayed, ready for further input.  
Figure 1: Using the question mark character (“?”) to display help for the current command.  
Manager > ADD ?  
Options : ACC APPletalk BGP CLASSifier BOOTp BRIDge DECnet FRamerelay GRE IP IPX  
ISDN LAPD LOG MIOX NTP OSPF PERM PPP RADius SA SCript SNmp STReam STT TRIGger  
TACacs USEr X25C X25T TDM  
Manager > ADD ACC ?  
Options : CALL SCript DOmainname  
Manager > ADD ACC CALL ?  
Options : DIrection DScript CScript RScript POrt ENcapsulation AUthentication  
DOmainname  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
20  
AT-8800 Series Switch User Guide  
Enabling Special Feature Licences  
You must enable the special feature licence you have purchased before you can  
use the licenced features. You will need the password provided by your  
authorised distributor or reseller. The advanced upgrade licence and password  
are different from the standard software release licence and password. The  
licence cannot be transferred from one switch to another.  
For software features that require a special feature licence see “Special Feature  
You must order passwords for special feature licences from your authorised distributor  
or reseller. You must specify the special feature licence bundle and the serial number(s)  
of the switch(s) on which the special feature licences are to be enabled.  
The password for a special feature licence is a string of at least 16 hexadecimal  
characters. This password encodes the special feature, or features, covered by  
the license, and the switch serial number. The password information is stored  
in the router’s FLASH memory.  
To enable or disable a special feature licence, enter the commands:  
ENABLE FEATURE=feature PASSWORD=password  
DISABLE FEATURE=feature  
To list the current special feature licences, enter the command:  
SHOW FEATURE[={featurename|index}]  
Setting System Parameters  
You can set some general system parameters to ensure the router’s  
compatibility with the public network, and to aid network administration.  
System name, location and contact parameters can help a remote network  
administrator identify the switch. By convention the system name is the full  
domain name. Set the name and location of the switch, for example:  
SET SYSTEM NAME=nd1.co.nz  
SET SYSTEM LOCATION=”Head Office, 3rd floor east”  
and a contact name and phone number for the network administrator  
responsible for the switch, for example:  
SET SYSTEM CONTACT=”Anna Brown 03-456 789”  
The name, location, and contact are strings 1 to 80 characters in length of any  
printable character. If the string includes spaces enclose it in double quotes.  
Set the router’s real time clock to the current local time in 24 hour notation  
(hh:mm:ss), and to the current date (dd-mmm-yy, or dd-mmm-yyyy), for  
example:  
SET TIME=14:50:00  
SET DATE=29-JAN-02 or  
SET DATE=29-JAN-2003  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Getting Started with the Graphical User Interface (GUI)  
21  
Chapter 3  
Getting Started with the Graphical User  
Interface (GUI)  
This Chapter  
This chapter describes how to access the switch’s HTTP-based Graphical User  
Interface (GUI), and provides basic information about using the GUI,  
including:  
What is the GUI?  
an introduction to the Graphical User Interface  
Accessing the switch via the GUI:  
browser and PC setup, including interaction with HTTP proxy servers  
establishing a connection to your switch, including an example of  
configuring SSL for secure access  
the System Status page, the first GUI page you see  
Using the GUI: navigation and features:  
an overview of the menus  
using configuration pages, with a description of key elements of GUI  
pages  
changing your password  
using the context sensitive online help  
saving your configuration  
combining GUI and CLI configuration  
configuring multiple devices  
Upgrading the GUI  
Troubleshooting  
diagnosing and solving connection problems  
using the GUI to troubleshoot the switch’s configuration.  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
22  
AT-8800 Series Switch User Guide  
What is the GUI?  
The GUI (Graphical User Interface) is a web-based device management tool,  
designed to make it easier to configure and monitor the switch. The GUI  
provides an alternative to the CLI (Command Line Interface). Its purpose is to  
make complicated tasks simpler and regularly performed tasks quicker.  
The GUI relies on an HTTP server that runs on the switch, and a web browser  
on the host PC. When you use the GUI to configure the switch, the GUI sends  
commands to the switch and the switch sends the results back to your browser,  
all via HTTP.  
The tasks you may perform using the GUI are not as comprehensive as the  
command set available on the CLI, but for some protocols, a few clicks of the  
mouse will perform many commands.  
The GUI is stored on the switch in the form of an embedded resource file, with  
file extension rsc. Resource files are model-specific, with the model and  
version encoded in the file name.  
Accessing the Switch via the GUI  
To use the GUI to configure the switch, you use a web browser to open a  
connection to the switch’s HTTP server. Therefore, you need a PC, a web  
browser and the switch. Supported browsers and operating systems, and the  
settings you need on your PC and browser, are detailed in the following  
Browser and PC Setup  
The GUI requires a web browser installed on a PC. Table 3 shows supported  
combinations of operating system and browser. A copy of Internet Explorer can  
be found on the switch’s Documentation and Tools CD-ROM.  
Table 3: Supported browsers and operating systems  
IE 5.0  
!
IE 5.5  
IE 6.0  
NS 6.2.2  
NS 6.2.3  
Windows 95  
Windows 98  
Windows ME  
Windows 2000  
Windows XP  
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
JavaScript must be enabled. To enable JavaScript in Internet Explorer:  
1. From the Tools menu, select Internet Options  
2. Select the Security tab  
3. Click on the Custom Level button  
4. Under the Scripting section, ensure that “Active scripting” is enabled.  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Getting Started with the Graphical User Interface (GUI)  
23  
To enable JavaScript in Netscape 6.2.x:  
1. From the Edit menu, select Preference  
2. Select the Advanced menu option.  
3. Ensure that the “Enable JavaScript for Navigator” checkbox is checked.  
The minimum screen resolution on the PC is 800x600.  
HTTP Proxy Servers  
An HTTP proxy server provides a security barrier between a private network’s  
PCs and the Internet. The PCs send HTTP requests (and other web traffic) to  
the server, which then forwards the requests appropriately. Similarly, the server  
receives incoming HTTP traffic addressed to a PC on the private network, and  
forwards it to the appropriate PC. Proxy servers can be used to block traffic  
from undesirable websites, to log traffic flows, and to disallow cookies.  
If your browser is configured to use a proxy server, and the switch is on your  
side of the proxy server, you will need to set the browser to bypass proxy  
entries for the IP address of the appropriate interface on the switch. (See  
giving switch interfaces IP addresses.)  
To ensure that your network’s security settings are not compromised, see your  
network administrator for information about bypassing the proxy server on  
your system.  
To bypass the proxy server on Internet Explorer, if your browser administration  
does not use a script, and the PC and the switch are in the same subnet:  
1. From the Tools menu, select Internet Options.  
2. Select the Connections tab and click the LAN Settings button.  
3. Check the “Bypass proxy server for local addresses” checkbox.  
4. If necessary, click the Advanced button and enter a list of local addresses.  
To bypass the proxy server on Netscape, if your browser does not use a script:  
1. From the Edit menu, select Preferences  
2. Click on the Advanced menu option to expand it.  
3. Select the Proxies menu option  
4. Enter the switch’s IP address in the “No Proxy for” list.  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
24  
AT-8800 Series Switch User Guide  
Establishing a Connection to the Switch  
Before you start, consider how the switch fits into your network. If you are  
installing a new switch, consider whether you want to configure it before  
deploying it into the LAN, or want to configure it in situ. If you want to access  
a switch that has already been configured, consider the relative positions of the  
PC and the switch. The flow chart below summarises this process, and the  
procedures that follow take you through each possibility in detail.  
Figure 2: A summary of the process for establishing a connection via the GUI.  
Start here  
Determine the IP address  
of an interface on the router  
Is the router  
already installed and  
and browse to it.  
Yes  
configured in  
the LAN?  
No  
Connect your PC directly to  
the router, give the router an  
IP address and browse to it.  
Do you want  
to configure the router  
before installing it in  
the LAN?  
Yes  
No  
Install the router into the LAN,  
give it an IP address and  
browse to it.  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Getting Started with the Graphical User Interface (GUI)  
25  
Option 1: Configuring the Switch before Installation  
Use this procedure if:  
You want to configure the switch before installing it in your LAN.  
You will be installing the switch at a remote office or a customer site and  
want to configure it first.  
You want a dedicated management PC permanently connected to the  
switch.  
1. Select a PC to browse to the switch from  
You can browse to the switch from any PC that is running a supported  
operating system with a supported browser installed. See “Browser and  
PC Setup” on page 22 for more information.  
You need to know the PC’s subnet.  
2. Connect the PC to the switch  
Use a straight-through Ethernet cable to connect an Ethernet card on the  
PC to any one of the switch ports (see Figure 3).  
Figure 3: Connecting a PC directly to the switch.  
You can browse to the switch through any VLAN, as long as you give that VLAN an IP  
address (see below). These instructions assume you will use vlan1. The switch ports all  
belong to vlan1 by default.  
3. Access the switch’s command line interface  
Access the CLI from the PC, as described in “Connecting a Terminal or PC”  
4. Enable IP  
ENABLE IP  
5. Assign the vlan1 interface an IP address in the same subnet as the PC  
ADD IP INTERFACE=vlan1 IP=ipaddress MASK=mask  
6. Save the configuration and set the switch to use it on bootup  
CREATE CONFIG=your-name.cfg  
SET CONFIG=your-name.cfg  
7. On the PC, bypass the HTTP proxy server, if necessary  
8. Point your web browser at the LAN interface’s IP address  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
26  
AT-8800 Series Switch User Guide  
9. At the login prompt, enter the user name and password  
The default username is manager:  
User Name: manager  
Password: friend  
The System Status page is displayed (Figure 6 on page 31). Select options  
from the sidebar menu to configure and manage the switch.  
Option 2: Installing the Switch into the LAN  
Use this procedure if:  
You want to install the switch into the LAN before you configure it.  
1. Select a PC to browse to the switch from  
You can browse to the switch from any PC that is running a supported  
operating system with a supported browser installed, with JavaScript  
You need to know the PC’s subnet.  
2. Plug the switch into the LAN  
To install the switch into the same subnet as the PC:  
Use an Ethernet cable to connect one of the switch ports to a device on the  
LAN segment, for example, a hub, router or switch (see Figure 4).  
Figure 4: Connecting the switch into the same LAN segment as the PC  
ON  
10BASE-T/100BASE-TX SWITCH PORTS  
4
3
2
1
OFF  
POWER  
Hub or Layer 2  
Switch  
PC  
AT-8800 Series Switch  
To install the switch into a different subnet than the PC:  
Use an Ethernet cable to connect any one of the switch ports to a device on  
the LAN segment in which you require the switch to work, for example, a  
hub, router or switch (see Figure 5).  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Getting Started with the Graphical User Interface (GUI)  
27  
Figure 5: Configuring the switch from a PC in another subnet.  
gateway  
subnet  
subnet  
AT-8800 Series Switch  
You can browse to the switch through any VLAN, as long as you give that VLAN an IP  
address (see below). These instructions assume you will use vlan1. The switch ports all  
belong to vlan1 by default.  
3. Access the switch’s command line interface  
Access the CLI from the PC, as described in “Connecting a Terminal or PC”  
4. Enable IP  
ENABLE IP  
5. Assign the vlan1 interface an IP address  
ADD IP INTERFACE=vlan1 IP=ipaddress MASK=mask  
If you use DHCP to assign IP addresses to devices on your LAN, and you want to  
manage the switch within this DHCP regime, it is recommended that you set your  
DHCP server to always assign the same IP address to the switch. This will enable you  
to access the GUI by browsing to that IP address, and will also let you use the switch as  
a gateway device for your LAN. If you need the switch's MAC address for this, you can  
display it using the command SHOW SWITCH. To set the interface to obtain its IP  
address by DHCP, use the commands:  
ADD IP INTERFACE=VLAN1 IPADDRESS=DHCP and  
ENABLE IP REMOTEASSIGN.  
where:  
PC-subnet is the IP subnet address of the PC. For example, if the PC has  
an IP address of 192.168.6.1 and a mask of 255.255.255.0, its subnet  
address is 192.168.6.0.  
gateway-ipaddress is the IP address of the gateway device that connects  
the PC’s subnet with the switch’s subnet (Figure 5 on page 27).  
6. If you want to be able to browse to the GUI securely, configure SSL (Secure  
Sockets Layer)  
7. Save the configuration and set the switch to use it on bootup  
CREATE CONFIG=filename.cfg  
SET CONFIG=filename.cfg  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
28  
AT-8800 Series Switch User Guide  
8. On the PC, bypass the HTTP proxy server, if necessary  
9. Point your web browser at the LAN interface’s IP address  
For normal access, point your web browser to  
http://ip-address  
For secure access, point your web browser to  
https://ip-address  
where ip-address is the interface’s IP address.  
10. At the login prompt, enter the user name and password  
The default username is manager:  
User Name: manager  
Password: friend  
The System Status page is displayed (see Figure 6 on page 31). Select  
options from the sidebar menu to configure and manage the switch.  
Option 3: Connecting to an Installed Switch  
Use this procedure if:  
At least one interface on the switch already has an IP address, and the  
switch is already installed in a LAN.  
1. Find out the IP address of the switch’s interface  
Ask your system administrator. Alternatively, access the CLI, as described  
SHOW IP INTERFACE  
You can browse to the switch through any VLAN, as long as you give that VLAN an IP  
address (see below). These instructions assume you will use vlan1. The switch ports all  
belong to vlan1 by default.  
2. Select a PC  
You can browse to the GUI from any PC that:  
has an IP address in the same subnet as the switch, or that the switch  
has a route to  
is running a supported operating system  
has a supported browser installed, with JavaScript enabled  
3. If necessary, bypass the HTTP proxy server  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Getting Started with the Graphical User Interface (GUI)  
4. Browse to the switch  
29  
For normal access, point your web browser to  
http://ip-address  
where ip-address is the interface’s IP address.  
To access the switch securely if SSL (Secure Sockets Layer) has been  
configured on the interface, point your web browser to  
https://ip-address  
For more information about secure access, see “Secure Access” on page 29.  
5. At the login prompt, enter the user name and password  
The default username is manager:  
User Name: manager  
Password: friend  
The System Status page is displayed (see Figure 6 on page 31). Select  
options from the sidebar menu to configure and manage the switch.  
If the Firewall and/or VPN (IPSec) have already been configured on the switch  
using the CLI, this configuration may conflict with the GUI. Do not attempt to  
modify existing CLI firewall or VPN configuration with the GUI.  
Secure Access  
You can optionally browse to the switch using Secure Sockets Layer (SSL). This  
means that sensitive data including passwords and email addresses can not be  
accessed by malicious parties. This section details the required configuration.  
For information about SSL, refer to the Secure Sockets Layer (SSL) chapter of  
your Software Reference.  
For this configuration to succeed your switch must have PKI, ISAKMP, SSH and SSL  
feature licences. If these licences are not already present on your switch, please contact  
your authorised distributor or reseller.  
To secure your switch’s HTTP Server with SSL for secure switch  
management via the GUI.  
1. Create a Security Officer user account  
Only a user with Security Officer privilege can enable system security and SSL.  
To add a user with the login name “CIPHER”, password “sbr4y3”,  
login=yes, and SECURITY OFFICER privilege, use the command:  
ADD USER="CIPHER" PASSWORD="sbr4y3"  
PRIVILEGE=SECURITYOFFICER Login=yes  
CREATE CONFIG=ssl.cfg  
RESTART SWITCH  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
30  
AT-8800 Series Switch User Guide  
2. Login as a Security Officer  
To login as the user with Security Officer privilege called “CIPHER”, use  
the command:  
LOGIN CIPHER  
And then enter the password for “CIPHER”, “sbr4y3”.  
3. Enable system security  
To enable system security, use the command:  
ENABLE SYSTEM SECURITY  
4. Create an RSA key pair for this switch.  
To create an RSA key pair, use the command:  
CREATE ENCO KEY=0 TYPE=RSA LENGTH=1024  
5. Set the switch’s distinguished name.  
To set the switch’s distinguished name to  
"cn=switch1,o=my_company,c=us", use the command:  
SET SYSTEM DISTINGUISHEDNAME="cn=switch1,  
o=my_company,c=us"  
6. Set the UTC offset.  
To set the Universal Coordinated Time to inform the switch that the  
difference between local time and GMT is 7 hours, use the command:  
SET LOG UTCOFFSET=7  
7. Create a self-signed certificate for the switch.  
To create a PKI certificate without contacting a CA for browsing to the GUI,  
use the command:  
CREATE PKI CERTIFICATE=cer_name KEYPAIR=0  
SERIALNUMBER=12345 SUBJECT="cn=172.30.1.105,  
o=my_company, c=us"  
Using this command creates a certificate that is only suitable for secure switch  
management via the GUI. A pop-up message will appear in the browser  
window warning that the certificate is not issued by a trusted authority. You  
should create a certificate via a Certification Authority if you want to use SSL  
with the Load Balancer. For details, see the Public Key Infrastructure (PKI)  
chapter of your Software Reference.  
8. Load self-signed switch certificate  
To load the signed switch certificate onto the switch, use the command:  
ADD PKI CERTIFICATE=cer_name LOCATION=cer_name.cer  
TRUST=YES  
9. Enable SSL on the HTTP server  
To enable SSL on the HTTP server with previously created SSL Key and the  
port 443, use the command:  
SET HTTP SERVER SECURITY=ON SSLKEY=0 PORT=443  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Getting Started with the Graphical User Interface (GUI)  
31  
10. Configure an IP interface to run SSL over  
To configure an IP interface that SSL will be run over, first enable IP using  
the command:  
ENABLE IP  
To make VLAN1the IP interface, and 172.30.1.105 the interface’s IP address,  
use the command:  
ADD IP INTERFACE=vlan1 IP=172.30.1.105  
To add an IP route on this interface with a next hop of 172.30.1.254, use the  
command:  
ADD IP ROUTE=0.0.0.0 INTERFACE=vlan1 NEXT=172.30.1.254  
For this example to succeed, you would have to log in as "cipher" rather than "manager"  
when connecting to the switch with a web browser.  
System Status  
The GUI opens to display the System Status page. Figure 6 points out key  
information contained on the page.  
Figure 6: The System Status page  
Model name  
Software release  
Help, Save and Exit  
Sidebar menu  
Port status  
System status  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
32  
AT-8800 Series Switch User Guide  
Using the GUI: Navigation and Features  
The GUI consists of a large number of pages, which you navigate between using  
the menu on the left of the browser window. This section describes how to use  
the GUI, and gives an overview of its functionality.  
The Configuration Menu  
You can use the GUI to configure:  
the system identity and mail server  
the system time, or NTP (Network Time Protocol)  
triggers, to automatically run scripts at a time you specify or in response  
to events you specify  
SNMP (Simple Network Management Protocol)  
switch port settings, including mirroring, trunking and storm limits  
802.1x port security  
VLANs, STP and GARP  
Internet Protocol: interfaces, static routes, the preferences of dynamic  
routes, RIP, multicasting, and OSPF  
IPX  
Quality of Service and traffic filters  
Using Configuration Pages  
Most protocols are configured by creating or adding an entry - a VLAN, a  
firewall rule, a DHCP policy, and so on. For such protocols, configuration with  
the GUI is based on sets of three pages: first you see a “summary” page, and  
from that you access an “add” page and a “modify” page. Complex protocols  
are sub-divided into different tabs, each with their own summary, add and  
modify pages.  
Only one person can configure a particular switch with the GUI at a time, to avoid  
clashes between configurations. Monitoring and diagnostics pages can be viewed by  
more than one user at a time.  
Use the menus and buttons on the GUI pages to navigate, not your browser’s buttons,  
to ensure that the configuration settings are saved correctly.  
The summary page displays a selection table of existing items and information  
about them (for example, existing PIM interfaces; see Figure 7 on page 33).  
Below the selection table is a row of buttons, labelled Add, Modify and  
Remove.  
To add a new item, click the Add button. This opens the popup “add” page,  
which lets you create a new item (for example, configure a new PIM interface;  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Getting Started with the Graphical User Interface (GUI)  
33  
To modify an existing item, select it by clicking on the option button at the  
beginning of its entry in the selection table. Then click the Modify button. This  
opens the popup “modify” page, which lets you expand or change the  
configuration (for example, change the Hello interval for a PIM interface; see  
To delete or destroy an item, select it by clicking on the option button at the  
beginning of its entry in the selection table. Then click the Remove button.  
Figure 7: An example of a configuration page with a selection table  
Tabs  
Heading row  
Radio button  
Add, Modify and  
Remove buttons  
Figure 8: An example of a popup “add” page  
Text field  
Select list  
Checkbox  
Apply and Cancel  
buttons  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
34  
AT-8800 Series Switch User Guide  
Figure 9: An example of a popup “modify” page  
Non-editable field  
Editable Fields  
GUI pages allow you to enter values or select options through a range of field  
types. These include:  
text fields, to enter character strings or numbers, especially for fields  
where there are few limits on the entries (such as names). See the online  
help for valid characters and field length  
select lists, to select one option from a small number of possibilities.  
Only valid options are listed. For example, if you are asked to select an  
IP interface from a drop-down list, the only interfaces displayed will be  
those you have assigned an IP address to  
radio button lists, to choose one of a series of mutually-exclusive  
options  
checkboxes, to enable or disable features.  
Ports Graphic  
Pages on which you can select switch ports use a Ports graphic - a visual  
representation of the switch ports.To toggle through the selection options, click  
on the icon representing the port you want to select or deselect.  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Getting Started with the Graphical User Interface (GUI)  
35  
Apply Button  
An Apply button applies the configuration settings on the page or the section  
of the page. The new settings will take effect immediately, but are not  
automatically saved. To save the settings after clicking Apply, click the Save  
button above the menu.  
Cancel Button  
A Cancel button closes a popup page without making any changes to the  
configuration.  
Close Button  
A Close button closes a popup page, and conserves any changes that you made  
to the settings on the page by clicking on buttons like Add, Modify, Remove or  
Apply. Changes you made to editable fields will not be conserved when you  
click Close (unless you first clicked Apply).  
The Management Menu  
You can use the GUI to manage the switch itself, including:  
creating user accounts and enabling system security  
creating and editing files  
backing files up to the switch’s Flash memory or to a PC or TFTP server  
restoring the switch’s configuration from backup  
specifying which software and configuration files the switch uses on  
bootup, and displaying the currently-used files  
enabling software release and feature licences  
upgrading the switch’s software  
The Monitoring Menu  
When you browse to the GUI, the sidebar menu opens to display the  
monitoring menu, opened at the System > Status. From this menu, you can also  
check:  
information about the switch’s hardware  
information about traffic over each port  
the Layer 2 Forwarding Database, which shows the MAC addresses  
that the switch ports have learned, and out which port the switch will  
switch traffic to each MAC address  
information about Address Resolution Protocol (ARP) entries  
the IP route table  
the log messages that the switch automatically generates. You can also  
set up filters to determine where messages are saved to and which  
messages are saved.  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
36  
AT-8800 Series Switch User Guide  
The Diagnostics Menu  
The GUI’s diagnostics pages enable you to troubleshoot network problems and  
observe traffic flow, including:  
displaying the number of good and bad packets received and  
transmitted over each switch port  
displaying the number and type of PPP packets received and  
transmitted  
displaying the number and type of packets received and transmitted by  
IP, and discarded by the IP gateway  
displaying the number and type of ICMP and UDP packets received  
and transmitted  
displaying the number and type of RIP packets received and  
transmitted; and the octets received and transmitted over each IP route  
displaying the contents of the switch’s file system and how much  
memory is used and available. You can also delete files  
an interface to the switch’s command line interface, allowing you to  
enter CLI commands.  
Changing the Password  
As a security precaution, change the password as soon as possible.  
To change the password of the default Manager account, select Management >  
Users from the sidebar menu. Select the Manager account and click Modify.  
For information about passwords, see “Changing a Password” on page 17.  
Context Sensitive GUI Help  
The GUI’s context-sensitive help system is displayed in a pop-up window  
which covers the title of the GUI page. You can move the banner to any part of  
your screen and/or resize it. To display the help, click on the Help button  
above the sidebar menu or on the page for which you require assistance. Three  
types of help are available:  
Help button  
Click General Page Info to see brief background and process flow  
information. The General Page Info displays when you click the Help  
button.  
Click Page Element Info and roll your mouse over an element, to see  
information about that element.  
To freeze the banner’s display so that the help does not change when you  
move the mouse, press the [Ctrl] key. To unfreeze, press [Ctrl] again. Note  
that element information is not available for entries in tables. To see  
descriptions of the columns of tables, click Complete Help Page.  
Click Complete Help Page to see all available information, including the  
element information, in a separate printable window.  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Getting Started with the Graphical User Interface (GUI)  
37  
Saving Configuration Entered with the GUI  
Configuration changes applied using the GUI can be saved to a configuration  
script by clicking the Save button at the top of the sidebar menu. A pop-up  
Save window gives you the option of saving to the current configuration file,  
another existing file, or a new file. You can also choose to use this configuration  
at bootup.  
Save button  
When the Save button is red, this indicates that changes have been made to the  
configuration and not yet saved. If you attempt to exit the GUI without saving  
the configuration, a pop-up window will allow you to choose whether or not to  
save.  
Combining GUI and CLI Configuration  
You can alternate between the GUI and the CLI without difficulty. Note that  
GUI pages will not automatically refresh to reflect changes in the CLI  
configuration; you must reload the relevant page (for example, by clicking the  
Refresh button on your browser).  
Configuring Multiple Devices  
If you are configuring a number of switches with similar requirements, you  
may wish to:  
1. Configure one device, using either the CLI or the GUI  
2. Save that configuration. This creates a configuration file, stored in the  
switch’s FLASH memory. The file consists of a sorted list of the CLI  
commands that make up the configuration  
3. Upload that file to a PC, using either the CLI or the GUI  
4. Open the file in a text editor, make changes as required, and download the  
file onto each switch you need to configure.  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
38  
AT-8800 Series Switch User Guide  
Upgrading the GUI  
You can download the latest GUI resource file from the support site at  
http://www.alliedtelesyn.co.nz. Before you start, ensure that the switch is running  
the most recent release and patch files. The GUI is not part of the firmware  
release file, but the most recent resource file will generally only be compatible  
with the most recent software release. To check which files the switch is  
running, refer to the “Current Install” section of the command:  
SHOW INSTALL  
If you are updating both the release and the resource file, set the preferred  
release and restart the switch before installing the GUI as described below.  
To upgrade the GUI  
1. If required, delete the old GUI resource file  
If required, you can store more than one GUI resource file on the switch at  
a time. If you want to delete the previous GUI resource file (for example, to  
save memory), you must first disable the GUI, using the command:  
DISABLE GUI  
Then delete the GUI resource file, using the command:  
DELETE FILE=old-gui.rsc  
where:  
old-gui.rsc is the name of the GUI resource file that you are replacing.  
Wait until FLASH compaction has finished. This will take several minutes.  
Do not interrupt the switch’s power supply during FLASH compaction, under  
any circumstances.  
If you have multiple valid resource files and releases stored on the switch, use the SET  
INSTALL command to change the release and resource file the switch uses (see below).  
2. Load the new file onto the switch  
Download the GUI resource file for your model of switch from the website  
to your TFTP server. Do not rename the file.  
Resource files use a fixed naming convention, which includes a product code, a language  
code and a version code. For example, filenames for the AR450S are of the form  
d450se01.rsc. If you change the GUI resource file’s name, the switch will not recognise  
it as a valid file and you will be unable to use it for configuration.  
Load the GUI resource file from your TFTP server to the switch, using the  
command:  
LOAD FILE=filename.rsc SERVER=server  
where:  
filename is the name of the GUI resource file, as shown on the support  
site for your switch. Do not rename the file.  
server is the IP address of the TFTP server the file is loaded from.  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Getting Started with the Graphical User Interface (GUI)  
39  
When the switch has loaded the file into its RAM, it displays the message  
File transfer successfully completed”. It then writes the file to FLASH  
memory, which takes approximately 30 seconds after the message. Once  
the file has been copied to FLASH, you can enter commands that refer to it.  
3. Install the new file as the preferred GUI  
If you are updating both the release and the resource file, set the preferred  
release and restart the switch before installing the GUI as described below.  
To set the new GUI resource file as the preferred resource file, use the  
command:  
SET INSTALL=preferred GUI=filename.rsc  
You can use the GUI to load the new resource file onto the switch  
(Management > Software > Upgrade), but you need to use the CLI to  
install the new file.  
If you disabled the GUI to delete the old resource file, enable it again, using  
the command:  
ENABLE GUI  
Check that the new GUI resource file is valid for your device, using the  
command:  
SHOW GUI  
If it is not, or if the file was corrupted during the download, disable the  
GUI, delete the file and try again.  
4. Point your web browser at the switch’s IP address  
Your browser may have a local copy of the old GUI file stored. If so, you  
need to delete these temporary files (see “Deleting Temporary Files” on  
Troubleshooting  
The GUI resource file has an 8-digit name, with the file extension rsc(for  
example, d450se01.rsc). To check which resource files are present on the  
switch use the command:  
SHOW FILE  
To see which GUI resource file the switch is currently using, and which it will  
use on bootup, use the command:  
SHOW INSTALL  
To display information about the GUI resource file that is currently installed,  
use the command:  
SHOW GUI  
In particular, this command lets you check the file’s validity. If the file is invalid  
or damaged, download a new file.  
To display information about the switch’s HTTP server, use the commands:  
SHOW HTTP SERVER  
SHOW HTTP SERVER SESSION  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
40  
AT-8800 Series Switch User Guide  
Deleting Temporary Files  
Browsers store local copies of web pages as temporary files. If you upgrade to a  
new GUI resource file, or if you encounter problems in browsing to the GUI,  
you may need to delete these files (clear the cache). To clear the cache in  
Internet Explorer:  
1. From the Tools menu, select Internet Options.  
2. On the General tab, click the Delete Files button.  
3. The Delete Files dialog box opens. Click the OK button.  
To clear the cache in Netscape 6.2.x:  
1. From the Edit menu, select Preferences  
2. Click on the Advanced menu option to expand it.  
3. Select the Cache menu option  
4. Click the Clear Memory Cache and Clear Disk Cache buttons.  
Accessing the Switch via the GUI  
Problem You cannot browse to the switch.  
Diagnosis Check if you can ping the switch’s interface from your PC. If you get a  
response, this indicates that the interface’s IP address is valid, and that your PC  
has a route to it.  
Solution  
If you cannot ping the switch’s interface:  
Check that your PC’s gateway is correct, so that your PC has a route to  
the switch.  
The IP address of the switch’s interface may be incorrect. To correct this,  
access the CLI and use the IPADDRESS parameter of command SET IP  
INTERFACE  
The IP address of the switch’s default gateway may be incorrect, so that  
the switch does not have a route back to your PC’s gateway. To correct  
this, access the CLI and use the NEXTHOP parameter of the command  
ADD IP ROUTE or SET IP ROUTE.  
If the switch should be dynamically assigned an IP address, check that the  
DHCP server can reach the switch, by pinging the switch from the DHCP  
server.  
If your PC accesses the Internet through a proxy server, you may need to  
set your browser to bypass the proxy when browsing to the switch’s IP  
information.  
If you cannot access the GUI because your username or password fails,  
check that you are spelling them correctly. The username “manager” will  
always be valid. Its default password is “friend”. Note that passwords are  
case sensitive.  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Getting Started with the Graphical User Interface (GUI)  
41  
Problem The GUI is behaving inconsistently, or you cannot access some pages.  
Solution  
Delete your browser’s temporary files (see “Deleting Temporary Files” on  
page 40) and try again.  
Check that you are trying to access the GUI from a supported operating  
for more information.  
Check that JavaScript is enabled.  
Problem The GUI does not seem to configure the switch correctly.  
Solution  
Use the buttons on the GUI pages to navigate, not your browser’s Back,  
Forward or Refresh buttons. The GUI’s navigation buttons perform aspects  
of the configuration.  
Traffic Flow  
Problem No traffic is passing through the switch to or from the LAN, the DMZ or  
both.  
Solutions  
Check that the switch’s link to the LAN is functioning, by checking the  
interface status (Monitoring) and that the link LED is lit. If the LED is not  
lit, or the appropriate interfaces do not have an status of “active”:  
Check that the port is enabled (Configuration > Port > Settings)  
Check that the IP address of the interface is still valid.  
Check that the cables are connected correctly and function correctly.  
Check the RIP configuration (Configuration > Internet Protocol > RIP).  
Check that the RIP neighbour can reach the switch, by pinging the  
switch from the RIP neighbour.  
Any password and authentication settings must be configured on the  
neighbour as well as on this switch.  
Check that the switch is passing the correct DNS information to hosts on  
the LAN, if the switch is a DHCP server. If the switch acting as a DHCP  
client as well, and therefore is passing on DNS information from another  
DHCP server, check that this DHCP server is providing the switch with the  
correct information.  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
42  
AT-8800 Series Switch User Guide  
IP Addresses and DHCP  
Problem The switch is enabled as a DHCP server, but cannot assign an IP address to a  
host.  
Solution  
Reboot the host machine.  
Check the host’s TCP/IP settings, to make sure that the host is set to obtain  
its IP address dynamically:  
In Windows 95/98, click Settings > Control Panel > Network. Select TCP/  
IP and click Properties. Click Obtain an IP address automatically.  
In Windows 2000, click Settings > Control Panel > Network and Dial-up  
Connections > Local Area Connection > Properties. Select Internet  
connection (TCP/IP) and click Properties. Click Obtain an IP address  
automatically.  
Check that the switch’s link to the LAN is functioning, by checking the  
interface status (Monitoring) and that the link LED is lit (see “Traffic Flow”  
Time and NTP  
Diagnosis The switch’s time is displayed on the Configuration > System > Time tab. It  
will also be included in log packets.  
Problem The switch’s time does not change, even though you entered the correct time.  
Solution Changing the time is a 3-step process. Select Configuration > System > Time.  
First, enter a time that is very shortly in the future (e.g. 20 seconds later than  
the current time). Then check Set time. Then wait until precisely the time you  
have entered, and click Apply.  
Problem The switch is not assigning the time to devices on the LAN.  
Solutions  
Check NTP is enabled (Configuration > System > Time).  
Check that the NTP peer’s IP address is entered correctly.  
Check that the NTP peer can reach the switch, by pinging the switch from  
the NTP peer.  
Check that the switch’s link to the LAN is functioning. See “Traffic Flow” on  
Problem The switch’s clock does not synchronise with the NTP peer.  
Solution  
The switch’s clock can only synchronise with the NTP peer if its initial time  
is similar to the NTP peer’s time (after setting the UTC offset). Manually  
set the switch’s time so that it is approximately correct, and enable NTP  
again.  
Check that the UTC offset is correct.  
Problem The switch’s time is incorrect, even though it assigns the correct time to  
devices on the LAN.  
Solution The UTC offset is probably incorrect, or needs to be adjusted for the beginning  
or end of summer time. To correct this, select Configuration > System > Time  
and enter the correct offset.  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Getting Started with the Graphical User Interface (GUI)  
43  
Loading Software  
Problem You have attempted to load a new release file onto the switch, but the load  
has failed and you cannot access the switch through the GUI.  
Solution 1. Access the switch’s CLI (see “Connecting a Terminal or PC” on page 14).  
If the switch has been switched off or has rebooted since you attempted to  
load the release file, it will boot up with the default installation. This  
contains the commands you require to load a file.  
Log into the switch using the manager account and password.  
2. Download the release file to the switch. See “Example: Upgrade to a New  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4  
Operating the switch  
This Chapter  
This chapter introduces basic operations on the switch, including:  
User Accounts and Privileges  
The switch software supports three levels of privilege for users: USER,  
MANAGER, and SECURITY OFFICER. By default, the switch has one account  
(manager) defined with manager privilege and the default password friend. The  
commands that a user can execute depends on the user’s privilege level and  
whether the switch is operating in normal or security mode (see “Normal Mode  
and Security Mode” on page 47). A USER level prompt looks like:  
>
while a MANAGER prompt looks like:  
Manager >  
and a SECURITY OFFICER prompt looks like:  
SecOff >  
The MANAGER level has access to the full set of commands when the switch is  
in normal mode. When the switch is operating in security mode, users with  
MANAGER privilege cannot execute a subset of the commands known as the  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
46  
AT-8800 Series Switch User Guide  
In normal mode, a user with manager privilege can create and delete accounts  
for users with any of these privilege levels. Users and passwords are managed  
by the User Authentication Facility. Users and passwords are authenticated  
using an internal database called the User Authentication Database, or by  
interrogation of external RADIUS (Remote Authentication Dial In User Service) or  
TACACS (Terminal Access Controller Access System) servers.  
On the CLI, to use an account with manager privilege, log in to the account by  
entering the command:  
LOGIN  
The switch prompts you to enter a user name and password. To return to USER  
mode, enter the command:  
LOGOFF  
Make sure that you do not leave a manager session unattended. Unauthorised  
use of a manager session gives access to the User Authentication Database. To  
reduce the risk of unauthorised activity, a subset of manager commands have a  
security timer. These commands are shown in Table 4 on page 46. When you  
enter one of these commands from a manager session, the security timer is  
started and is then restarted each time you enter another of these commands. If  
you enter one of these commands after the timer has expired, you are  
prompted to re-enter the password. The secure delay timer is by default 60  
seconds. If the password is not entered correctly the password prompt is  
repeated a set number of times. If the correct password is still not entered a log  
message is generated and the session is logged off.  
The security timer enables a manager to make successive additions and  
modifications to the database at one time without having to re-enter the  
password for every command.  
The security timer does not provide a foolproof security mechanism. Managers  
should always attempt to log out of a manager session before leaving a  
terminal unattended.  
Table 4: Secure commands controlled by the security timer.  
Command  
Description  
ADD TACACS SERVER  
Adds a TACACS server to the list of TACACS servers used  
for user authentication.  
ADD USER  
Adds a user to the User Authentication Database.  
DELETE TACACS SERVER  
Deletes a TACACS server from the list of TACACS servers  
used for user authentication.  
DELETE USER  
PURGE USER  
Deletes a user from the User Authentication Database.  
Deletes all users except MANAGER from the User  
Authentication Database.  
SET MANAGER PORT  
SET USER  
Assigns a port semipermanent MANAGER privilege.  
Modifies a user record in the User Authentication Database.  
If the switch is operating in security mode, the manager must also log in to a user  
account with SECURITY OFFICER privilege in order to execute any of the commands  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Operating the switch  
47  
See the Operations chapter in the AT-8800 Series Switch Software Reference for:  
More information about managing and using accounts with user, manager  
and security officer privileges  
A full list of commands that require security officer privilege when the  
switch is in secure mode  
Information about enabling a remote security officer.  
Normal Mode and Security Mode  
The switch operates in one of two modes, either normal mode or security  
mode. By default, the switch is in normal mode.  
When the switch is in security mode, the command SHOW DEBUG does not display  
output of the SHOW FEATURE and SHOW CONFIGURATION DYNAMIC  
commands, or the current configuration in the SHOW SYSTEM output unless the  
SHOW DEBUG command is entered by a user with security officer privilege.  
If you wish to use the following software features you need to enable security  
mode:  
IP authentication  
Secure Shell (see the Secure Shell chapter, AT-8800 Series Switch Software  
Reference)  
Encryption (see the Compression and Encryption Services chapter, AT-8800  
Series Switch Software Reference)  
IPsec (see the IP Security chapter, AT-8800 Series Switch Software Reference)  
Public Key Encryption (PKI) (see the Public Key Infrastructure chapter, AT-  
8800 Series Switch Software Reference)  
Secure Sockets Layer (SSL) (see the Secure Sockets Layer chapter, AT-8800  
Series Switch Software Reference)  
To enable security mode, first create a user with security officer privilege, then  
enter the command:  
ENABLE SYSTEM SECURITY_MODE  
To access secure functionality you will need to log in again as the security  
officer.  
When the switch restarts, it restarts in the same normal mode or security mode  
as it was before restarting. To restore the switch to normal operating mode,  
enter the command:  
DISABLE SYSTEM SECURITY_MODE  
When security mode is disabled, the switch automatically deletes all sensitive  
data files, including encryption keys.  
To display the current operating mode, enter the command:  
SHOW SYSTEM  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
48  
AT-8800 Series Switch User Guide  
When the switch is in security mode, a user with security officer privilege is the  
only person who can execute commands which affect switch security. Table 5  
on page 48 lists commands that only a security officer can execute when the  
switch is in security mode. A complete list of commands limited by security  
mode are listed in the Operation chapter in the AT-8800 Series Switch Software  
Reference.  
Table 5: Commands requiring SECURITY OFFICER privilege when the switch is  
operating in security mode .  
Command  
Specific Parameters  
ACTIVATE SCR  
ADD IP INT  
ADD SCR  
ADD USER  
CREATE CONFIG  
CREATE ENCO KEY  
CREATE PPP  
CREATE PPP TEMPLATE  
CREATE SNMP COMMUNITY  
DEACTIVATE SCR  
DELETE FILE  
DELETE SCR  
DELETE USER  
DISABLE USER  
DUMP  
EDIT  
ENABLE PPP DEBUG  
ENABLE PPP TEMPLATE DEBUG  
ENABLE SNMP  
ENABLE USER  
LOAD  
MODIFY  
PURGE USER  
RENAME FILE  
RESET ENCO  
RESET USER  
SET CONFIG  
SET INSTALL  
SET IP INT  
SET PPP  
SET PPP TEMPLATE  
SET SCR  
SET SNMP COMMUNITY  
SET USER  
SHOW CONFIG  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Operating the switch  
49  
Table 5: Commands requiring SECURITY OFFICER privilege when the switch is  
operating in security mode (Continued).  
Command  
SHOW FILE  
SHOW PPP  
UPLOAD  
Specific Parameters  
CONFIG  
Remote Management  
You can manage remote switches as easily as you manage the local switch a  
terminal is connected to. From a terminal connected to any port (with either  
USER or MANAGER privilege), enter the command:  
TELNET ipadd  
to Telnet to the remote switch, specifying the remote router’s IP address.  
switchFor information about how to set routes and on how you assign an IP  
If the connection is successful, a login prompt from the remote switch is  
displayed. Login using a login name that has been defined with MANAGER  
privilege (such as the default MANAGER login name), and enter the  
password.  
To return to the local switch and terminate the connection, enter the command:  
LOGOFF  
For more information about using Telnet, see the Terminal Server chapter in the  
AT-8800 Series Switch Software Reference.  
Storing Files in FLASH Memory  
When you purchase the switch, the switch software release, the online help  
files, and a default configuration file are stored in FLASH memory, where they  
are saved even if the switch is powered down. You will use the FLASH  
memory to store updated software releases or patches, and files that record the  
router’s configuration. FLASH memory is like a flat file system, with no  
subdirectories.  
The switch also has Random Access Memory (RAM). The switch software uses  
RAM to run the switch. When you enter commands to configure the switch  
these commands affect the dynamic configuration in RAM.  
FLASH memory is like a flat file system, with no subdirectories.  
File names of up to 16 characters long, with extensions of 3 characters (DOS  
16.3 format), are supported on the switch. However, files on the switch are  
stored in FLASH using the DOS 8.3 format of 8 characters long, with  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
50  
AT-8800 Series Switch User Guide  
extensions of 3 characters. For example, the file extralongfilenam.cfgmay  
be saved as extral~1.cfgin the FLASH File System. Therefore, files can be  
accessed via two file names, either of which can be used for file management.  
A translation table, named longname.lfn, converts file names between DOS  
16.3 format and DOS 8.3 format. To reconcile file names the switch consults the  
translation table which is synchronised with file contents in memory. For more  
information about working with files see the Working With Files section,  
Operation chapter, AT-8800 Series Switch Software Reference.  
To display the files in FLASH, enter the command:  
SHOW FILE  
Figure 10: Example output from the SHOW FILE command.  
Filename  
Device  
Size  
Created  
Locks  
----------------------------------------------------------------------------  
28-72.pat  
flash  
flash  
flash  
flash  
flash  
flash  
111764 05-May-1997 12:41:42  
2013756 09-May-1997 15:58:55  
123268 18-Apr-1997 15:58:16  
0
0
0
0
0
0
28-74ang.rel  
28f72-06.pat  
release.lic  
test.cfg  
32  
08-May-1997 16:43:49  
09-May-1997 10:39:42  
30-May-1997 15:10:12  
1698  
24  
sixteenalongfile.scp  
----------------------------------------------------------------------------  
The Locks field indicates the number of concurrent software processes using the file.  
The switch automatically compacts FLASH memory when a maximum  
threshold of deleted files is reached. Compaction frees space for new files by  
discarding garbage. A message will appear when FLASH compaction is  
activated. Another message appears when FLASH compaction is complete.  
While FLASH is compacting, do not restart the switch or use any commands  
that affect the FLASH file subsystem. Do not restart the switch, or create, edit,  
load, rename or delete any files until a message confirms that FLASH file  
compaction is completed. Interrupting flash compaction may result in damage  
to files.  
Using Scripts  
When you start or restart the switch, or when it automatically restarts, it  
executes the configuration commands in the boot script. A boot script is a text  
file containing a sequence of standard commands that the switch executes at  
startup. The default boot script is called boot.cfg. Commands run from a boot  
script are limited to 128 characters.  
The commands you enter into the switch from the command line affect only  
the dynamic configuration in RAM, which is not retained over a power cycle.  
The switch does not automatically store these changes in FLASH memory.  
When the switch is restarted, it loads the configuration defined by the boot  
script, or if the switch was restarted using the RESTART command, any script  
file specified in the RESTART command.  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Operating the switch  
51  
In addition to the boot configuration script that the switch automatically runs  
when it restarts, you can run a configuration script manually at any time, by  
entering the command:  
ACTIVATE SCRIPT=filename  
You can also set a trigger to automatically execute a configuration script when  
a specified event occurs.  
For more information about how to create and run scripts, see the Scripting  
chapter in the AT-8800 Series Switch Software Reference.  
For information about creating triggers, see the Trigger Facility chapter in the  
AT-8800 Series Switch Software Reference.  
Saving the Switch’s Configuration  
To view the router’s current dynamic configuration, enter the command:  
SHOW CONFIGURATION DYNAMIC  
To save any changes made to the dynamic configuration after the switch last  
restarted (booted) across a restart or power cycle, and save the modified  
configuration as a script file, enter the command:  
CREATE CONFIG=filename.scp  
To set the switch to execute this script file when it restarts, enter the command:  
SET CONFIG=filename.scp  
The configuration file created by CREATE CONFIG command records passwords in  
encrypted form, not in cleartext.  
You can create a script file from any of the switch software commands. These  
are the same commands that are used to change the router’s configuration  
dynamically. Manually edit a configuration file using the router’s built in  
UPLOAD command (see the Operation chapter, AT-8800 Series Switch Software  
Reference), edit it using any text editor, and download it again. Give  
configuration script files an extension of .scpor .cfg.  
To display the name of the configuration file that is set to execute when the  
switch restarts, enter the command:  
SHOW CONFIG=filename  
Storing Multiple Scripts  
You can store multiple configuration scripts on the switch. This allows you to  
test new configuration scripts once, before setting them as the default  
configuration. For example, to test the new configuration script test.cfg,  
enter the command:  
RESTART SWITCH CONFIG=test.cfg  
Storing multiple scripts also allows you to keep a backup switch with  
configuration scripts stored on it for every switch in the network to speed up  
network recovery time.  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
52  
AT-8800 Series Switch User Guide  
Loading and Uploading Files  
When you want to upgrade your switch to a new software patch or release, or  
use a new configuration file, load files onto the switch using the router’s  
LOADER module. You can also use the LOADER module to upload files, such  
as configuration files or log files, from the switch onto a host on the network.  
File Naming Conventions  
The file subsystem provides a flat file system—directories are not supported.  
Files are uniquely identified by a file name of the form:  
[device:]filename.ext  
where:  
device specifies the physical memory device on which the file is stored,  
FLASH. If device is specified, it must be separated from the rest of the file  
name by a colon (“:”). device is optional. If device is not specified, the default  
is FLASH.  
filename is a descriptive name for the file, and may be one to eight  
characters in length. Valid characters are lowercase letters (a–z), uppercase  
letters (A–Z), digits (0–9) and the hyphen character (-).  
ext is a file name extension, one to three characters in length. Some file  
name extensions are shown in Figure 6 on page 52. Valid characters are  
lowercase letters (a–z), uppercase letters (A–Z), digits (0–9) and the hyphen  
character (-). The extension is used by the switch to determine the data  
type of the file and how to use the file (Table 6 on page 52). If ext is  
specified, it must be separated from the filename portion by a period (“.”)  
Table 6: File extensions and file types .  
Extension  
CER  
File type/function  
Public Key Infrastructure (PKI) certificate file.  
Configuration or boot script.  
CFG  
CRL  
PKI Certificate Revocation List file.  
PKI Certificate Signing Request file.  
(Graphics Interchange Format) graphic image file.  
CLI help file.  
CSR  
GIF  
HLP  
HTM  
INS  
HTML file used by the HTTP server.  
Stores install information created by using the SET INSTALL  
command.  
JPG  
KEY  
LIC  
(Joint Photographic Experts Group) graphic image file.  
Public portion of an RSA key.  
Licence information.  
Log file.  
LOG  
MDS  
REL  
Modem script.  
Software release.  
Compressed release.  
Script.  
REZ  
SCP  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Operating the switch  
53  
Table 6: File extensions and file types (Continued).  
Extension  
File type/function  
SPA  
Spam Mail Source files, listing email addresses, identified as spam  
mail sources, to be blocked by the firewall SMTP proxy, if it is  
active.  
SPL  
TXT  
VPF  
LFN  
VPN client.  
Generic text file.  
Future VPN client.  
Extension used for the long file name translation table  
You may see files on your switch with file name extensions not listed in Table 6  
on page 52. If you require more information about file types and file name  
extensions, contact your authorised distributor or reseller.  
Do not change the header in a release or patch file. At best, this will cause the  
file load or install to fail, at worst the switch could be put into a state where it  
will not boot correctly until field service action is taken.  
Loading Files  
The LOADER module is responsible for loading and storing releases, patches,  
PKI certificates and other files into FLASH. The LOADER module uses the  
Trivial File Transfer Protocol (TFTP), Hypertext Transfer Protocol (HTTP), or  
ZMODEM over an asynchronous port, to retrieve files from a network host.  
You can also load text files without using any of these protocols. For  
information about using Lightweight Directory Access Protocol (LDAP) to  
load PKI certificates or certificate revocation lists (CRLs), see the Operation  
chapter in the AT-8800 Series Switch Software Reference.  
The router’s default download method is TFTP. To load a file onto the switch  
from a TFTP server using the TFTP protocol, enter the command:  
LOAD [METHOD=TFTP] [DELAY=delay] [DESTFILE=destfilename]  
[DESTINATION={BOOTBLOCK|FLASH}] [SERVER={hostname|ipadd}]  
[SRCFILE|FILE=filename]  
To load a file onto the switch using the HTTP protocol, enter the command:  
LOAD [METHOD={HTTP|WEB|WWW}] [DELAY=delay]  
[DESTFILE=destfilename] [DESTINATION=BOOTBLOCK|FLASH}]  
[HTTPPROXY={hostname|ipadd} [PASSWORD=password]  
[PROXYPORT=1..65535]] [SERVER={hostname|ipadd}]  
[SERVPORT={1..65535|DEFAULT}] [SRCFILE|FILE=filename]  
[USERNAME=username]  
The switch can only load one file at a time. Wait for the current transfer to  
complete before initiating another transfer. To display the default configuration  
of the LOADER module, and the progress of any current transfer, enter the  
command:  
SHOW LOADER  
To stop a load at any time, leaving the LOADER module ready to load again,  
enter the command:  
RESET LOADER  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
54  
AT-8800 Series Switch User Guide  
Setting LOADER Defaults  
You are likely to repeat the process of downloading files onto the switch using  
a similar method each time. You can set defaults for some or all of the LOADER  
parameters. You can then use or override some or all of these defaults for each  
particular load.  
To set LOADER defaults, enter the command:  
SET LOADER [ATTRIBUTE={CERT|CRL|CACERT|DEFAULT}]  
[BASEOBJECT={dist-name|DEFAULT}] [DELAY={delay|DEFAULT}]  
[DESTFILE=dest-filename] [DESTINATION={FLASH|DEFAULT}]  
[HTTPPROXY={hostname|ipadd|DEFAULT}]  
[METHOD={HTTP|LDAP|TFTP|WEB|WWW|ZMODEM|NONE|DEFAULT}]  
[PASSWORD=password] [PROXYPORT={1..65535|DEFAULT}]  
[{SCRFILE|FILE}=filename]  
[SERVER={host-name|ipadd|DEFAULT}]  
[SERVPORT={1..65535|DEFAULT}] [USERNAME=username]  
You can set all parameters except DESTFILE, SCRFILE and FILE back to the  
factory defaults with the option DEFAULT.  
For more information about setting the LOADER defaults on your switch, see  
the Operations chapter in the AT-8800 Series Switch Software Reference.  
Example: Load a Patch File Using HTTP  
This example loads a patch file onto the switch from an HTTP server on the  
network. Before following this procedure, make sure:  
The HTTP server is operating on a host with an IP address (for example  
192.168.1.1) on the network, and that the patch file is in the server’s HTTP  
directory.  
The switch has an IP address (for example 192.168.1.2) on the interface  
connecting it to the HTTP server, and that it can communicate with the  
server.  
There is enough space in the router’s FLASH for the new patch file.  
To load a patch file  
1. Configure the LOADER.  
Set the LOADER module with defaults to make the process of  
downloading files in future simpler.  
SET LOADER METHOD=HTTP SERVER=192.168.1.1  
DESTINATION=FLASH  
2. Download the patch file.  
Download the patch file onto the switch, using the defaults set above.  
LOAD FILE=52232-01.paz  
When the download has completed, check that the file is in FLASH.  
SHOW FILE  
This shows the file 52232-01.pazis present.  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Operating the switch  
55  
Uploading Files From the Switch  
The LOADER can upload files from the switch to a network host, using TFTP  
or ZMODEM. Upload files using one of the commands:  
UPLOAD [METHOD=TFTP] [FILE=filename]  
[SERVER={hostname|ipadd}]  
UPLOAD [METHOD=ZMODEM] [FILE=filename] [ASYN=port]  
The UPLOAD command uses defaults set with the SET LOADER command,  
for parameters not specified with the upload command.  
You can install Allied Telesyn’s Trivial File Transfer Protocol Server (AT-TFTP  
Server) on any PC or server running Windows. This will provide a simple way  
to make files available to all Allied Telesyn routers and layer 3 switches in your  
network. The TFTP Server, and a readme file describing how to install and use  
it, are provided on the AT-8800 Series Switch Documentation and Tools CD-ROM.  
Example: Upload a Configuration File Using TFTP  
This example uploads a configuration file from the switch to a TFTP server on  
the network. Before following this procedure, make sure:  
The TFTP server is operating on a host with an IP address (for example  
192.168.1.3) on the network.  
The switch has a valid IP address (for example 192.168.1.2) on the interface  
connecting it to the TFTP server, and that it can communicate with the  
server.  
The configuration file is present in the router’s FLASH.  
To upload a log file:  
1. Configure the LOADER.  
Set the LOADER module with defaults to make the process of  
downloading and uploading files in future simpler.  
SET LOADER METHOD=TFTP SERVER=192.168.1.3  
2. Upload the configuration file.  
Upload the configuration file from the switch into the TFTP directory of the  
TFTP server on the network, using the defaults set above.  
UPLOAD FILE=filename.cfg  
Monitor the load progress.  
SHOW LOAD  
When the upload is complete, check that the file is in the TFTP directory on  
the network host.  
More information  
For more information about loading files onto and uploading files from the  
switch, including using LDAP to load PKI certificate information, see the  
Operation chapter in the AT-8800 Series Switch Software Reference.  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
56  
AT-8800 Series Switch User Guide  
Upgrading Switch Software  
When you first start the switch, it automatically loads the software release from  
FLASH memory into RAM, where the CPU uses it to run all the router’s  
software features. The switch may also load a patch file to improve the main  
release. The software release and any patch files are current when the switch is  
produced at the factory.  
When Allied Telesyn makes a new patch or release available, you may want to  
upgrade the software on your switch to use a new patch or release file. You can  
download the latest software patches, full software releases, and CLI help files  
from the support site at: http://www.alliedtelesyn.co.nz/support/ar400.  
Make sure you download a patch or release file that matches your switch  
model. A patch or release file for AT-8800 Series Switch has 86 as the first two  
digits of the filename. Patch files have the file extension .pazand release files  
have the file extension .rez. For example, the Software Release 2.6.1 for the  
AR450S has the filename 86s-261.rez.  
Release and patch files are compressed ASCII files, and consist of a header  
followed by a sequence of Motorola S-records containing the actual code for  
the release or patch. The header has a standard format, which provides  
information about the release or patch to the switch.  
Do not change the header in a release or patch file. At best, this will cause the  
file load or install to fail, at worst the switch could be put into a state where it  
will not boot correctly until field service action is taken.  
The current release and patch file are set as the preferred install. The switch  
also has a very limited version of the software stored in a specific part of  
FLASH (the FLASH boot block). You cannot delete this version as it is the  
default, or boot install. When you load a new software release or patch, you can  
set it to run once, the next time the switch reboots. This temporary install  
allows you to test run a new release or patch once, before you make it the  
preferred install. If the temporary install fails the switch will automatically run  
the preferred install if there is one, or otherwise the default install, the next  
time the switch reboots.  
When the switch reboots, it checks the install information in a strict order:  
Firstly, the switch checks the temporary install. If a temporary install is  
specified, the switch loads it into RAM and runs it. At the same time, it  
deletes the temporary install information so it will not load a second  
time. This information is deleted even if the temporary install triggers a  
fatal condition causing the switch to reboot immediately.  
Secondly, if no temporary install is defined, or the install information is  
invalid, the switch checks the preferred install. If present, this install is  
loaded. The switch never deletes the preferred install information.  
Thirdly, if neither a temporary install nor a preferred install is specified,  
the switch loads the default install. The default install is always present  
in the switch because if, for some reason, it is not, the INSTALL module  
will restore it.  
The preferred install should not be set up with an untested release or patch. It  
is advisable to install new releases or patches as the temporary install, and  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Operating the switch  
57  
when the switch boots correctly, to then set up the preferred install with the  
new release or patch.  
To change the install information in the switch, enter the command:  
SET INSTALL={TEMPORARY|PREFERRED|DEFAULT}  
[RELEASE={release-name|EPROM}] [PATCH=patch-name]  
For security reasons the SET INSTALL command is only accepted if the user has  
SECURITY OFFICER privilege.  
When you set a patch file as part of a temporary install or permanent install,  
you must also set the corresponding release file in the same command, if it has  
not already been set as part of that install. You can set the patch, but not the  
release (always EPROM), for the default install.  
To delete a temporary install or preferred install, enter the command:  
DELETE INSTALL={TEMPORARY|PREFERRED}  
If a default install is set, only the patch information is deleted using the  
DELETE INSTALL command as the release information must always be left  
intact in the default install.  
To display the current install information, including which install is currently  
running in the switch, and how the install information was checked at the last  
reboot, enter the command:  
SHOW INSTALL  
For more information about INSTALL commands, see the Operations chapter in  
the AT-8800 Series Switch Software Reference.  
Example: Upgrade to a New Software Release Using  
TFTP  
This example assumes the switch is correctly configured to allow TFTP to  
function. This means that IP is configured and the switch is able to  
communicate with the designated TFTP server. The TFTP server is assumed to  
function correctly and the release and patch files are assumed present in the  
server’s TFTP directory. The switch has no patch files, and is running the  
Software Release 2.6.1. The IP address of the server is 172.16.1.1. The name of  
the release file being loaded is 86s-262.rez.  
To upgrade to a new software release:  
1. Configure the LOADER.  
The LOADER module is set up with defaults to make the process of  
downloading files in future simpler. All release and patch files in this  
switch are stored in FLASH.  
SET LOADER METHOD=TFTP SERVER=172.16.1.1 DEST=FLASH  
2. Load the new release file onto the switch.  
Make sure there is space in FLASH for the new release file. Load the new  
file onto your switch. Make sure the release file matches your switch model  
required, and the help file for the release (see “Loading and Uploading Files”  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
58  
AT-8800 Series Switch User Guide  
on page 52). To load the release file using your LOADER default settings,  
enter the command:  
LOAD FILE=86s-262.rez  
Wait for the release to load. This can take several minutes, even if you are  
loading the file over a high speed link. To see the progress of the load, enter  
the command:  
SHOW LOAD  
To check that the files are successfully loaded, enter the command:  
SHOW FILE  
3. Enter licence information for the release.  
Enter the licence password for the software release.  
ENABLE RELEASE=86s-262.rez PASSWORD=ce645398fbe  
NUMBER=2.6.2  
The release licence password is provided by your authorised distributor or  
reseller and is unique for the release number (in this case 2.6.2), the file  
name and the router’s serial number.  
Enter passwords for any special feature licences.  
ENABLE FEATURE=feature PASSWORD=password  
4. Test the release.  
Set the new release to run as a temporary install. This sets the switch to  
load the new release once only when it reboots.  
SET INSTALL=TEMPORARY RELEASE=86s-262.rez  
If you want to use the current switch configuration again, store the  
dynamic configuration as a configuration script file and set the switch to  
use this configuration when it restarts. Releases are generally backward-  
compatible, so your current configuration should run with little or no  
modifications on the later release.  
CREATE CONFIG=myconfig.cfg  
SET CONFIG=myconfig.cfg  
The SET CONFIG information survives the release update.  
Reboot the switch.  
RESTART REBOOT  
The switch reboots, loading the new release file and the specified  
configuration. Display the install history, and check that the temporary  
release was loaded.  
SHOW INSTALL  
5. Make the release the default (permanent) release.  
If the switch operates correctly with the new release, make the release  
permanent.  
SET INSTALL=PREFERRED RELEASE=86s-262.rez  
Every time the switch reboots from now on, it loads the new release from  
FLASH.  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operating the switch  
59  
Example: Upgrade to a new patch file  
Use this procedure to upgrade the software release currently running on the  
switch with a new patch. This example assumes that the current release,  
Software Release 2.6.1, is set as the preferred release.  
To upgrade to a new patch file:  
1. Load the new patch file onto the switch.  
Load the new file onto your switch. See Loading and Uploading Files” on  
LOAD FILE=86261-01.paz  
Check that the file is successfully loaded.  
SHOW FILE  
2. Test the patch.  
Set the release to run as a temporary install, so that it loads the patch once  
only the next time it reboots.  
SET INSTALL=TEMPORARY RELEASE=86s-261.rez  
PATCH=86261-01.paz  
If you want to use the current switch configuration again, store the  
dynamic configuration as a configuration script file, and set the switch to  
use this configuration when it restarts.  
CREATE CONFIG=myconfig.scp  
SET CONFIG=myconfig.scp  
Reboot the switch.  
RESTART REBOOT  
The switch reboots, loading the new patch file and the specified  
configuration. Check that the switch operates correctly with the new patch  
file.  
3. Make the patch part of the default (permanent) release.  
If the switch operates correctly with the new patch, make the release  
permanent.  
SET INSTALL=PREFERRED RELEASE=86s-261.rez  
PATCH=86261-01.paz  
Every time the switch reboots from now on, it loads the new release and  
patch from FLASH.  
Do not set an untested patch as part of the preferred install.  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
60  
AT-8800 Series Switch User Guide  
Using the Built-in Editor  
The AT-8800 Series Switch has a built-in full-screen text editor for editing script  
files stored on the switch file subsystem. Using the text editor you can run  
script files manually, or set script files to run automatically at switch restart, or  
on trigger events. Figure 11 on page 60 shows a example screen shot of the text  
editor. To start the editor with a new file or an existing file, enter the command:  
EDIT [filename]  
Figure 11: The editor screen layout.  
The editor uses VT100 command sequences and should only be used with a  
VT100-compatible terminal, terminal emulation program or Telnet client.  
To display editor Help at any time while in the editor press [Ctrl/K,H]; that is,  
hold down the Ctrl key and press in turn the K key then the H key.  
For more information about the inbuilt editor, see the Operation chapter in the  
AT-8800 Series Switch Software Reference.  
SNMP and MIBs  
You can remotely monitor some features of the switch using Simple Network  
Management Protocol (SNMP).  
For information about the MIBs supported by the switch, see Appendix C:  
SNMP MIBs in the AT-8800 Series Switch Software Reference.  
The SNMP agent is disabled by default. To enable SNMP, enter the command:  
ENABLE SNMP  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Operating the switch  
61  
SNMP communities are the main configuration item in the router’s SNMP  
agent, and are defined in terms of a list of IP addresses which define the SNMP  
application entities (trap hosts and management stations) in the community. To  
create an SNMP community, enter the command:  
CREATE SNMP COMMUNITY=name [ACCESS={READ|WRITE}]  
[TRAPHOST=ipadd] [MANAGER=ipadd]  
[OPEN={ON|OFF|YES|NO|TRUE|FALSE}]  
The community name is a security feature and you should keep it secure.  
To enable the generation of authentication failure traps by the SNMP agent  
whenever an SNMP authentication failure occurs, enter the command:  
ENABLE SNMP AUTHENTICATE_TRAP  
To enable the generation of link state traps for a specified interface, enter the  
command:  
ENABLE INTERFACE=interface LINKTRAP  
where interface is the name of an interface, such as “vlan11”.  
For more information see the Simple Network Management Protocol (SNMP)  
chapter and the Interfaces chapter in the AT-8800 Series Switch Software Reference.  
To display the current state and configuration of the SNMP agent, enter the  
command:  
SHOW SNMP  
For a detailed description of the output from the SHOW SNMP command, see  
the Simple Network Management Protocol (SNMP) chapter in the AT-8800 Series  
Switch Software Reference.  
For More About Operations and Facilities  
For more detail about operating the switch, and for full command syntax  
definitions, see the Operation chapter in the AT-8800 Series Switch Software  
Reference, including:  
How to use the User Authentication Facility, RADIUS, TACACs or  
TACACS+ for authenticating users who log on to the switch, and ensuring  
that only authorised login accounts are used.  
How to use the HTTP Client, which you can use to download software files  
onto the switch, and the HTTP Server.  
How to use the Mail Subsystem.  
How to use LDAP to load PKI certificates and CRLs onto your switch.  
Switch Startup Operations  
How to use FLASH compaction to regain storage space on the switch. Read  
Warning about FLASH memory” on page 12 before you attempt to do this.  
How to set aliases to represent common command strings.  
How to define a remote security officer, so you can manage the security  
features remotely via Telnet.  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
62  
AT-8800 Series Switch User Guide  
See other chapters in the AT-8800 Series Switch Software Reference for more  
information on how to:  
Use the logging facility to monitor network activity and to select and  
display the results (see the Logging Facility chapter).  
Use SNMP to manage the switch remotely (see the Simple Network  
Management Protocol (SNMP) chapter and Appendix C: SNMP MIBs).  
Use the command line to create, delete and modify configuration scripts  
(see the Scripting chapter).  
Set up triggers to automatically run specified scripts at specified times, or  
at specified events (see the Trigger Facility chapter).  
Use NTP to synchronise your router’s time clock with those of other  
network devices (see the Network Time Protocol (NTP) chapter).  
Use software to test whether the router’s hardware functions correctly (see  
the Test Facility chapter).  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 5  
Layer 2 Switching  
This section describes the Layer 2 switching features on the AT-8800 Series  
Switch, and how to configure them.  
Switch Ports  
Each Ethernet switch port is uniquely identified by a port number. The switch  
supports a number of features at the physical level that allow it to be connected  
in a variety of physical networks. This physical layer (layer 1) versatility  
includes:  
Enabling and disabling of Ethernet ports.  
Auto negotiation of port speed and duplex mode for all 10/100 Ethernet  
ports.  
Manual setting of port speed and duplex mode for all 10/100 Ethernet  
ports.  
Link up and link down triggers.  
Port trunking.  
Packet storm protection.  
Port mirroring.  
Support for SNMP management  
Enabling and Disabling Switch Ports  
An switch port that is enabled is available for packet reception and  
transmission. Its administrative status in the Interfaces MIB is UP. Conversely,  
an Ethernet port that is disabled is not available for packet reception and  
transmission. It will not send or receive any frames; incoming STP BPDU  
packets are discarded. Its administrative status in the Interfaces MIB is DOWN.  
Every Ethernet port on the switch is enabled by default. Disabling a switch  
port does not affect the STP operation on the port. Enabling a switch port will  
allow the port to participate in spanning tree negotiation. A switch port that  
has been disabled by the Port Security feature cannot be enabled using the  
ENABLE SWITCH PORT command.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
64  
AT-8800 Series Switch User Guide  
To enable or disable a switch port, use the commands:  
ENABLE SWITCH PORT={port-list|ALL}  
DISABLE SWITCH PORT={port-list|ALL}  
Resetting Ethernet ports at the hardware level discards all frames queued for  
reception or transmission on the port, and restarts autonegotiation of port  
speed and duplex mode. Ports are reset using the command:  
RESET SWITCH PORT={port-list|ALL} [COUNTER]  
To display information about switch ports, use the command:  
SHOW SWITCH PORT[={port-list|ALL}]  
Figure 12: Example output from the SHOW SWITCH PORT command.  
Switch Port Information  
---------------------------------------------------------------------------  
Port .......................... 1  
Description ................... To intranet hub, port 4  
Status ........................ ENABLED  
Link State .................... Up  
UpTime ........................ 00:10:49  
Port Media Type ............... ISO8802-3 CSMACD  
Configured speed/duplex ....... Autonegotiate  
Actual speed/duplex ........... 1000 Mbps, full duplex  
Configured master/slave mode .. Autonegotiate  
Actual master/slave mode ...... Master  
Acceptable Frame Types ........ Admit All Frames  
Broadcast rate limit .......... 1000/s  
Multicast rate limit .......... -  
DLF rate limit ................ -  
Learn limit ................... -  
Intrusion action .............. Trap  
Current learned, lock state ... 15, not locked  
Mirroring ..................... Tx, to port 22  
Is this port mirror port ...... No  
Enabled flow control .......... Pause  
Send tagged pkts for VLAN(s) .. marketing (87)  
sales (321)  
Port-based VLAN ............... accounting (42)  
Ingress Filtering ............. OFF  
Trunk Group ................... -  
STP ........................... company  
Multicast filtering mode ...... (B) Forward all unregister groups  
---------------------------------------------------------------------------  
Table 7: Parameters in the output of the SHOW SWITCH PORT command  
Parameter  
Port  
Meaning  
The number of the switch port.  
Description  
Status  
A description of the port.  
The state of the port; one of “ENABLED” or “DISABLED”.  
The link state of the port, one of “Up” or “Down”.  
Link state  
Uptime  
The count in hours:minutes:seconds of the elapsed time  
since the port was last reset or initialised.  
Port Media Type  
The MAC entity type as defined in the MIB object ifType.  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Layer 2 Switching  
65  
Table 7: Parameters in the output of the SHOW SWITCH PORT command  
Parameter  
Meaning  
Configured speed/duplex  
The port speed and duplex mode configured for this port.  
One of “Autonegotiate” or a combination of a speed (one  
of “10 Mbps”, “100 Mbps” or “1000 Mbps”) and a duplex  
mode (one of “half duplex” or “full duplex”).  
Actual speed/duplex  
The port speed and duplex mode that this port is actually  
running at. A combination of a speed (one of “10 Mbps”,  
“100 Mbps” or “1000 Mbps”) and a duplex mode (one of  
“half duplex” or “full duplex”).  
Configured master/slave mode The master/slave mode configured for this port; one of  
“Autonegotiate’, “Master”, “Slave” or “Not applicable”.  
Actual master/slave mode  
Acceptable Frames Types  
Broadcast rate limit  
Multicast cast rate limit  
DLF rate limit  
The master/slave mode actually selected; one of “-”,  
“Master”, “Slave” or “Not applicable”.  
The value of the Acceptable Frames Type parameter, one of:  
“Admit All Frames” or “Admit Only VLAN-tagged Frames”.  
The limit of the rate of reception of broadcast frames for  
this port, in frames per second.  
The limit of the rate of reception of multicast frames for this  
port, in frames per second.  
The limit of the rate of reception of DLF (destination lookup  
failure) frames for this port, in frames per second.  
Learn limit  
The number of MAC addresses that may be learned for this  
port. Once the limit is reached, the port is locked against  
any new MAC addresses. One of “None” or a number from  
1 to 256.  
Intrusion action  
The action taken on this port when a frame is received from  
an unknown MAC address when the port is locked. One of  
“None”, “Discard”, “Trap” or “Disable”.  
Current learned, lock state  
The number of MAC addresses currently learned on this  
port and the state of locking for this port. The lock state is  
one of “not locked”, “locked by limit” or “locked by  
command”.  
Mirroring  
The traffic mirroring for traffic in and out of this port. One  
of “None”, “Rx” (for traffic received by this port), “Tx” (for  
traffic sent on this port) or “Both”. The port to which  
mirrored frames are being sent is also displayed.  
Is this port mirror port  
Enabled flow control(s)  
Whether or not this port is a mirror port. One of “No” or  
“Yes”.  
Flow control parameters set for the port; “Pause” or “-”. If  
flow control is implemented on the switch, then Pause flow  
control is applied to the port.  
Send tagged pkts for VLAN(s) The name and VLAN Identifier (VID) of the tagged VLAN(s),  
if any, to which the port belongs.  
Port-based VLAN  
The name and VLAN Identifier (VID) of the port-based VLAN  
to which the port belongs.  
Ingress Filtering  
Trunk Group  
STP  
The state of Ingress Filtering: one of “ON” or “OFF”.  
Name of trunk group to which the port belongs, if any.  
The name of the STP to which the port belongs.  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
66  
AT-8800 Series Switch User Guide  
Autonegotiation of Port Speed and Duplex Mode  
Each of the switch ports can operate at either 10 Mbps or 100 Mbps, in either  
full duplex or half duplex mode. In full duplex mode a port can transmit and  
receive data simultaneously, while in half duplex mode the port can either  
transmit or receive, but not at the same time. This versatility makes it possible  
to connect devices with different speeds and duplex modes to different ports  
on the switch. Such versatility also requires that each port on the switch know  
which speed and mode to use.  
Autonegotiation allows the ports to adjust their speed and duplex mode to  
accommodate the devices connected to them. Each switch port can be either  
configured with a fixed speed and duplex mode, or configured to  
autonegotiate speed and duplex mode with a device connected to it to  
determine a speed and mode that will allow successful transmission. An  
autonegotiating port will adopt the speed and duplex mode required by  
devices connected to it. If another autonegotiating device is connected to the  
switch, they will negotiate the highest possible common speed and duplex  
mode (Table 8 on page 67). Setting the port to a fixed speed and duplex mode  
allows it to support equipment that cannot autonegotiate.  
It is also possible to require a port to operate at a single speed without  
disabling autonegotiation by allowing the port to autonegotiate but constrain  
the speed/duplex options to the desired combination. For example, if one end  
of a link is set to AUTO and other to 100MFULL then the AUTO end will select  
100MHALF operation because without the other end autonegotiating the  
AUTO end has no way of knowing that the fixed end is full duplex capable. If a  
particular speed is required it is usually preferable to fix the speed/duplex  
combination using one of the autonegotiating speed values. Therefore, using  
100MFAUTO at one end of a link and will allow the AUTO end to  
autonegotiate 100MFULL.  
Switch ports will autonegotiate by default when they are connected to a new  
device. To change this setting, use the command:  
SET SWITCH PORT={port-list|ALL}  
SPEED={AUTONEGOTIATE|10MHALF|10MFULL|10MHAUTO|10MFAUTO|10  
0MHALF|100MFULL|100MHAUTO|100MFAUTO|1000MHALF|1000MFULL|1  
000MHAUTO|1000MFAUTO}  
Autonegotiation can also be activated at any time after this, on any port that is  
set to autonegotiate, by using the command:  
ACTIVATE SWITCH PORT={port-list|ALL} AUTONEGOTIATE  
On the first switch, the gigabit uplink ports always use 1000 Mbps speed and  
operate in full duplex mode, but these ports can also autonegotiate with peers  
in order to successfully pass the negotiation phase to get to successful  
operation.  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Layer 2 Switching  
67  
Table 8: Port speed and duplex settings for Ethernet Ports .  
AT-8824  
AT-8848  
Speed  
10/100  
Yes  
Yes  
Yes  
Yes  
No  
10MHALF  
10MFULL  
100MHALF  
100MFULL  
1000MHALF  
1000MFULL  
10MHAUTO  
10MFAUTO  
100MHAUTO  
100MFAUTO  
1000MHAUTO  
1000MFAUTO  
AUTONEGOTIATE  
No  
Yes  
Yes  
Yes  
Yes  
No  
No  
Yes  
The SHOW SWITCH PORT command displays the port speed and duplex  
mode settings.  
Port Trunking  
Port trunking, also known as port bundling or link aggregation, allows a  
number of ports to be configured to join together to make a single logical  
connection of higher bandwidth. This can be used where a higher performance  
link is required, and makes links even more reliable.  
The switch supports up to 6 trunk groups, of up to 8 switch ports each. The two  
gigabit Ethernet ports can also be grouped together to form a trunk group. It is  
not possible for a trunk group to include both 10/100 Ethernet and gigabit  
Ethernet ports. Ports in the trunk group do not have to be contiguous. Port  
trunking is supported between AR800 Series and Rapier switches, and may be  
compatible with trunking algorithms on third party devices.  
Port trunk groups are created and destroyed on the switch using the  
commands:  
CREATE SWITCH TRUNK=trunk [PORT=port-list]  
[SELECT={MACSRC|MACDEST|MACBOTH|IPSRC|IPDEST|IPBOTH}]  
[SPEED={10M|100M|1000M}]  
DESTROY SWITCH TRUNK=trunk  
Port trunk groups can only be destroyed on the switch if no ports belong to  
them.  
All the ports in a trunk group must belong to the same VLAN. Ports in a trunk  
group can be added to other VLANs, either as individual ports or as an entire  
group. A port in a trunk group cannot be deleted from any of the VLAN(s) to  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
68  
AT-8800 Series Switch User Guide  
which the whole trunk group belongs, unless it is first removed from the trunk  
group. The members of a trunk group can be specified when it is created, and  
ports can be added to or removed from a trunk group using the commands:  
ADD SWITCH TRUNK=trunk PORT=port-list  
DELETE SWITCH TRUNK=trunk PORT={port-list|ALL}  
Ports which are members of a trunk group must operate in full duplex mode.  
When a port is added to a trunk group, the speed setting for the group  
overrides the speed setting previously configured for the port. When a port is  
removed from a trunk group, the port returns to its previously configured  
speed and duplex mode settings.  
The speed of the trunk group can either be specified when it is created, or set  
using the command:  
SET SWITCH TRUNK=trunk  
[SELECT={MACSRC|MACDEST|MACBOTH|IPSRC|IPDEST|IPBOTH}]  
[SPEED={10M|100M|1000M}]  
The SELECT parameter specifies the port selection criterion for the trunk  
group. Each packet to be sent on the trunk group is checked, using the selection  
criterion, and a port in the trunk group chosen down which to send the packet.  
If MACSRC is specified, the source MAC address is used. If MACDEST is  
specified, the destination MAC address is used. If MACBOTH is specified,  
both source and destination MAC addresses are used. If IPSRC is specified, the  
source IP address is used. If IPDEST is specified, the destination IP address is  
used. If IPBOTH is specified, both the source and destination IP addresses are  
used. The user of the switch should choose the value of this parameter to try to  
spread out the load as evenly as possible on the trunk group. The default for  
this parameter is MACDEST.  
The SPEED parameter specifies the speed of the ports in the trunk group. For  
gigabit ports, only the value 1000M is allowed. For switch ports, values of 10M  
and 100M are allowed. The default is 100M. When a port is added to a trunk  
group, its current speed and duplex mode settings are ignored and the port  
uses the speed of the trunk group and full duplex mode.  
To display information about trunks on the switch, use the command:  
SHOW SWITCH TRUNK[=trunk]  
To display the VLANs to which the ports in the trunk groups belong, use the  
command:  
SHOW VLAN[=ALL]  
Port trunking must be configured on both ends of the link, or network loops may result.  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Layer 2 Switching  
69  
Packet Storm Protection  
The packet storm protection feature allows the user to set limits on the  
reception rate of broadcast, multicast and destination lookup failure packets.  
The software allows separate limits to be set for each port, beyond which each  
of the different packet types are discarded. The software also allows separate  
limits to be set for each of the packet types. Which of these options can be  
implemented depends on the model of switch hardware.  
By default, packet storm protection is set to NONE, that is, disabled. It can be  
enabled, and each of the limits can be set using the command:  
SET SWITCH PORT=port-list [BCLIMIT={NONE|limit}]  
[DLFLIMIT={NONE|limit}] [MCLIMIT={NONE|limit}]  
Packet storm protection limits cannot be set for each individual port on the  
switch, but can be set for each processing block of ports. The processing blocks  
are sets of 8 ports (e.g. as many as are applicable of ports 1-8, 9-16, 17-24, 25-32,  
33-40 and 41-48) and each uplink port is a further processing block. Therefore, a  
24-port switch has five processing blocks and a 48-port switch has eight. The  
two uplink ports are numbered sequentially after the last port, and therefore  
are 25 and 26 for a 24-port switch, and 49 and 50 for a 48-port switch. Only one  
limit can be set per processing block, and then applies to all three packet types.  
Thus each of the packet types are either limited to this value, or unlimited  
(NONE).  
The BCLIMIT parameter specifies a limit on the rate of reception of broadcast  
packets for the port(s). The value of this parameter represents a per second rate  
of packet reception above which packets will be discarded, for broadcast  
packets. If the value NONE or 0 is specified, then packet rate limiting for  
broadcast packets is turned off. If any other value is specified, the reception of  
broadcast packets will be limited to that number of packets per second. See the  
note below for important information about packet rate limiting. The default  
value for this parameter is NONE.  
The DLFLIMIT parameter specifies a limit on the rate of reception of  
destination lookup failure packets for the port. The value of this parameter  
represents a per second rate of packet reception above which packets will be  
discarded, for destination lookup failure packets. If the value NONE or 0 is  
specified, then packet rate limiting for destination lookup failure packets is  
turned off. If any other value is specified, the reception of destination lookup  
failure packets will be limited to that number of packets per second. See the  
note after the BCLIMIT parameter description for important information about  
packet rate limiting. The default value for this parameter is NONE. If packet  
storm protection limits are set on the switch, the PORT parameter must specify  
complete processing blocks.  
A destination lookup failure packet is one for which the switch hardware does not have  
a record of the destination address of the packet, either Layer 2 or Layer 3 address. These  
packets are passed to the CPU for further processing, so limiting the rate of reception of  
these packets may be a desirable feature to improve system performance.  
The MCLIMIT parameter specifies a limit on the rate of reception of multicast  
packets for the port. The value of this parameter represents a per second rate of  
packet reception above which packets will be discarded, for multicast packets.  
If the value NONE or 0 is specified, then packet rate limiting for multicast  
packets is turned off. If any other value is specified, the reception of multicast  
packets will be limited to that number of packets per second. See the note after  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
70  
AT-8800 Series Switch User Guide  
the BCLIMIT parameter description for important information about packet  
rate limiting. The default value for this parameter is NONE. If packet storm  
protection limits are set on the switch, the PORT parameter must specify  
complete processing blocks.  
The ability of the switch to limit packet reception rates for different classes of packets is  
dependent on the particular switch hardware. In particular, groups of ports may have to  
have the same limits set, and the same limit may be set for the different types of packets,  
depending on the hardware. Whenever packet rate limits are set on switches which have  
this type of constraint, the latest parameter values entered will supersede earlier values.  
When a command entered for specified ports changes the parameters for other ports, a  
message will indicate these changes.  
The SHOW SWITCH PORT command displays the packet storm protection  
SHOW SWITCH PORT=port-list  
Port Mirroring  
Port mirroring allows traffic being received and transmitted on a switch port to  
be sent to another switch port, the mirror port, usually for the purposes of  
capturing the data with a protocol analyser. This mirror port is the only switch  
port which belongs to no VLANs, and therefore does not participate in any  
other switching. Before the mirror port can be set, it must be removed from all  
VLANs except the default VLAN. The port cannot be part of a trunk group.  
To set the mirror port (and remove it from the default VLAN) use the  
command:  
SET SWITCH MIRROR={NONE|port}  
If another port was previously set as the mirror port, this command returns the previous  
mirror port to the default VLAN as an untagged port. Return this port to any VLANs  
to which it should belong, using the ADD VLAN PORT command, or set it as a tagged  
port using the SET VLAN PORT command if required.  
Either traffic received on a port or traffic transmitted by the port, or both, can  
be mirrored. This setting and the source port(s) from which traffic is sent to the  
mirror port are specified using the command:  
SET SWITCH PORT={port-list|ALL} MIRROR={NONE|RX|TX|BOTH}  
Mirroring four or more ports may significantly reduce switch performance.  
The MIRROR parameter specifies the role of these port(s) as a source of mirror  
traffic. If NONE is specified, no traffic received or sent on these port(s) will be  
mirrored. If RX is specified, all traffic received on these port(s) will be mirrored.  
If TX is specified, all traffic transmitted on these port(s) will be mirrored. If  
BOTH is specified, all traffic received and transmitted will be mirrored. Traffic  
will actually only be mirrored if there is a mirror port defined and if mirroring  
is enabled. The default is NONE.  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Layer 2 Switching  
71  
To send packets that match particular criteria to the mirror port, first create a  
classifier or classifiers using the command:  
CREATE CLASSIFIER  
Then create a hardware filter with the ACTION parameter set to  
SENDMIRROR, using the command:  
ADD SWITCH HWFILTER CLASSIFIER=classifier-list  
ACTION=SENDMIRROR  
By default mirroring is disabled, no mirror port is set, and no source ports are  
set to be mirrored. Mirroring can only be enabled after the switch mirror port  
has been set to a valid port. If mirroring has been enabled but the switch mirror  
port is set to NONE, then mirroring will be disabled. Mirroring is enabled and  
disabled using the commands:  
ENABLE SWITCH MIRROR  
DISABLE SWITCH MIRROR  
The SHOW SWITCH PORT and SHOW SWITCH commands display the  
switch and port mirroring settings.  
Port security  
The port security feature allows control over the stations connected to each  
switch port, by MAC address. If enabled on a port, the switch will learn MAC  
addresses up to a user-defined limit from 1 to 256, then lock out all other MAC  
addresses. One of the following options can be specified for the action taken  
when an unknown MAC address is detected on a locked port:  
Discard the packet and take no further action,  
Discard the packet and notify management with an SNMP trap,  
Discard the packet, notify management with an SNMP trap and disable the  
port.  
To enable port security on a port, set the limit for learned MAC addresses to a  
value greater than zero, and specify the action to take for unknown MAC  
addresses on a locked port. To disable port security on a port, set the limit for  
learned MAC addresses to zero or NONE. Port security can be enabled or  
disabled on a port using the command:  
SET SWITCH PORT={port-list|ALL} LEARN={NONE|0|1..256}  
[INTRUSIONACTION={NONE|DISCARD|TRAP|DISABLE}]  
The INTRUSIONACTION parameter specifies the action taken when the  
port(s) receive packets from addresses which are not part of the learned list of  
addresses as specified by the LEARN parameter. If DISCARD is specified,  
packets received from MAC addresses not on the port’s learn list will be  
discarded. If TRAP is specified, packets received from MAC addresses not on  
the port’s learn list will be discarded and an SNMP trap will be generated. If  
DISABLE is specified, the first time a packet is received from a MAC address  
not on the port’s learn list, it will be discarded, an SNMP trap will be generated  
and the port(s) will be disabled. To re-enable the port, disable the Port Security  
function on the port. The default value for this parameter is DISCARD.  
If INTRUSIONACTION is set to TRAP or DISABLE, a list of MAC addresses  
for devices that are active on a port, but which are not allowed or learned for  
the port, can be displayed using the command:  
SHOW SWITCH PORT={port-list|ALL} INTRUSION  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
72  
AT-8800 Series Switch User Guide  
Table 9: Example output from the SHOW SWITCH PORT INTRUSION command.  
Switch Port Information  
----------------------------------------------------------------------------  
Port 2 - 13 intrusion(s) detected  
00-00-c0-1d-2c-f8 00-90-27-87-a5-22 00-00-cd-01-00-4a  
00-d0-b7-4d-93-c0 08-00-5a-a1-02-3f 00-d0-b7-d5-5f-a9  
00-b0-d0-20-d1-01 00-90-99-0a-00-49 00-10-83-05-72-83  
00-00-cd-00-45-9e 00-00-c0-ad-a3-d0 00-a0-24-8e-65-3c  
00-90-27-32-ad-61  
----------------------------------------------------------------------------  
A switch port can be manually locked before it reaches the learning limit, by  
using the command:  
ACTIVATE SWITCH PORT={port-list|ALL} LOCK  
Addresses can be manually added to a port locked list up to a total of 256 MAC  
addresses, and the learning limit can be extended to accommodate them, by  
using the command:  
ADD SWITCH FILTER ACTION={FORWARD|DISCARD} DESTADDRESS=macadd  
PORT=port [ENTRY=entry] [LEARN] [VLAN={vlanname|1..4094}]  
Learned addresses on locked ports can be saved as part of the switch  
configuration, so that they will be part of the configuration after a power cycle,  
using the command:  
CREATE CONFIG=filename  
If the configuration is not saved when there is a locked list for a port, the  
learning process begins again after the switch is restarted.  
Virtual Local Area Networks (VLANs)  
A Virtual LAN (VLAN) is a logical, software-defined subnetwork. It allows  
similar devices on the network to be grouped together into one broadcast  
domain, irrespective of their physical position in the network. Multiple VLANs  
can be used to group workstations, servers, and other network equipment  
connected to the switch, according to similar data and security requirements.  
Decoupling logical broadcast domains from the physical wiring topology  
offers several advantages, including the ability to:  
Move devices and people with minimal, or no, reconfiguration  
Change a device’s broadcast domain and access to resources without  
physically moving the device, by software reconfiguration or by moving its  
cable from one switch port to another  
Isolate parts of the network from other parts, by placing them in different  
VLANs  
Share servers and other network resources without losing data isolation or  
security  
Direct broadcast traffic to only those devices which need to receive it, to  
reduce traffic across the network  
Connect 802.1Q-compatible switches together through one port on each  
switch  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Layer 2 Switching  
73  
Devices that are members of the same VLAN only exchange data with each  
other through the switch’s switching capabilities. To exchange data between  
devices in separate VLANs, the switch’s routing capabilities are used. The  
switch passes VLAN status information, indicating whether a VLAN is up or  
down, to the Internet Protocol (IP) module. IP uses this information to  
determine route availability.  
The switch has a maximum of 255 VLANs, ranging from a VLAN identifier  
(VID) of 1 to 4094. When the switch is first powered up, a “default” VLAN is  
created and all ports are added to it. In this initial unconfigured state, the  
switch will broadcast all the packets it receives to the default VLAN. This  
VLAN has a VID of 1 and an interface name of vlan1. It cannot be deleted, and  
ports can only be removed from it if they also belong to at least one other  
VLAN. The default VLAN cannot be added to any STP, but always belongs to  
the default STP. If all the devices on the physical LAN are to belong to the same  
logical LAN, that is, the same broadcast domain, then the default settings will  
be acceptable, and no additional VLAN configuration is required.  
VLAN Tagging  
An Ethernet packet can contain a VLAN tag, with fields that specify VLAN  
membership and user priority. The VLAN tag is described in IEEE Standard  
802.3ac, and is four octets that can be inserted between the Source Address and  
the Type/Length fields in the Ethernet packet (Figure 13 on page 74). To  
accommodate the tag, Standard 802.3ac also increased the maximum allowable  
length for an Ethernet frame to 1522 octets (the minimum size is 64 octets).  
IEEE Standard 802.1Q specifies how the data in the VLAN tag is used to switch  
frames. VLAN-aware devices are able to add the VLAN tag to the packet  
header. VLAN-unaware devices cannot set or read the VLAN tag.  
Table 10 on page 73 lists the meaning and use of the fields in the Ethernet  
frame. Figure 13 on page 74 shows the format of VLAN data in an Ethernet  
frame. Twelve bits of the tag are the VLAN Identifier (VID), which indicates the  
VLAN that the packet belongs to. Table 11 on page 74 lists the VLAN Identifier  
values that have specific meaning.  
Table 10: Fields in the Ethernet frame for QoS and VLAN switching.  
Field  
Length  
Meaning and use  
TPID  
2 octets  
The Tag Protocol Identifier (TPID) is defined by IEEE Standard  
802.1Q as 0x81-00.  
User Priority  
3 bits  
The User Priority field is the priority tag for the frame, which  
can be used by the switch to determine the Quality of  
Service to apply to the frame. The three bit binary number  
represents eight priority levels, 0 to 7.  
CFI  
1 bit  
The Canonical Format Indicator (CFI flag) is used to indicate  
whether all MAC address information that may be present  
in the MAC data carried by the frame is in canonical format.  
VID  
12 bits  
The VLAN Identifier (VID) field uniquely identifies the VLAN  
to which the frame belongs.  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
74  
AT-8800 Series Switch User Guide  
Figure 13: Format of user priority and VLAN data in an Ethernet frame.  
Destination  
Address  
Source Type/  
Address Length  
CRC  
Preamble  
64 bits  
Frame Data  
368-12000  
16  
32 bits  
48 bits  
48 bits  
bits  
User  
TPID  
Priority CFI  
VID  
12 bits  
16 bits  
3 bits  
0x81-00  
SWITCH6  
Table 11: Reserved VID values .  
VID value (hexadecimal) Meaning and use of reserved VID values  
0
The null VLAN ID. Indicates that the tag header contains only  
user priority information; no VLAN Identifier is present in the  
frame. This VID value must not be configured in any Forwarding  
Database entry, or used in any management operation. Frames  
that contain the null VLAN ID are also known as priority-tagged  
frames.  
1
The default VID value used for classifying frames on ingress  
through an untagged switch port.  
FFF  
Reserved for implementation use. This VID value must not be  
configured in any Forwarding Database entry, used in any  
management operation, or transmitted in a tag header.  
Ethernet packets which contain a VLAN tag are referred to as tagged frames,  
and switch ports that transmit tagged frames are referred to as tagged ports.  
Ethernet packets which do not contain the VLAN tag are referred to as untagged  
frames, and switch ports that transmit untagged frames are referred to as  
untagged ports. VLANs can consist of simple logical groupings of untagged  
ports, in which the ports receive and transmit untagged packets. Alternatively,  
VLANs can contain only tagged ports, or a mixture of tagged and untagged  
ports.  
The switch is VLAN aware. It can accept VLAN tagged frames, and supports  
the VLAN switching required by such tags. A network can contain a mixture of  
VLAN aware devices, for example, other 802.1Q-compatible switches, and  
VLAN unaware devices, for example, workstations and legacy switches that  
do not support VLAN tagging. The switch can be configured to send VLAN  
tagged or untagged frames on each port, depending on whether or not the  
devices connected to the port are VLAN aware. By assigning a port to two  
different VLANs, to one as an untagged port and to another as a tagged port, it  
is possible for the port to transmit both VLAN-tagged and untagged frames. A  
port must belong to a VLAN at all times unless the port has been set as the  
mirror port for the switch.  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Layer 2 Switching  
75  
Every frame admitted by the switch has a VID associated with it. If a frame  
arrives on a tagged port, the associated VID is determined from the VLAN tag  
the frame had when it arrived. If a frame arrives on an untagged port, it is  
associated with the VID of the VLAN for which the incoming port is untagged.  
When the switch forwards a frame over a tagged port, it adds a VLAN tag to  
the frame. When the switch forwards the frame over an untagged port, it  
transmits the frame as a VLAN-untagged frame, not including the VID in the  
frame.  
The VLAN tag that the switch adds to a frame on egress depends on whether  
the frame is switched in Layer 3 or Layer 2. In Layer 3 switching, the switch  
determines the destination VLAN from its routing tables. The VID of the  
destination VLAN will be added to the frame on egress. In Layer 2 switching,  
the frame’s source and destination VLANs are the same. The VID that was  
associated with the frame on ingress will be associated with it on egress.  
VLAN Membership using VLAN Tags  
Ports can belong to many VLANs as tagged ports. Therefore, when the VLAN  
tag is used to determine which VLAN a packet belongs to, it is easy to:  
Share network resources, such as servers and printers, across several  
VLANs  
Configure VLANs that span several switches  
For tagged ports, the switch uses the VID of incoming frames, and the frame’s  
destination field to switch traffic through a VLAN aware network. Frames are  
only transmitted on ports belonging to the required VLAN. Other vendors’  
VLAN aware devices on the network can be configured to accept traffic from  
one or more VLANs. A VLAN-aware server can be configured to accept traffic  
from many different VLANs, and then return data to each VLAN without  
mixing or leaking data into the wrong VLANs.  
Figure 14 on page 76 shows a network configured with VLAN tagging.  
Table 12 on page 76 shows the VLAN membership. The server on port 2 on  
Switch A belongs to both the admin and marketing VLANs. The two switches  
are connected through uplink port 26 on Switch A and uplink port 25 on  
Switch B, which belong to both the marketing VLAN and the training VLAN, so  
devices on both VLANs can use this link.  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
76  
AT-8800 Series Switch User Guide  
Figure 14: VLANs with tagged ports.  
Training VLAN VID=3  
Port 3  
Port 21  
Port 22  
Port 26  
Port 4  
Switch B  
Switch A  
Port 25  
Port 1  
Port 2  
Port 23  
Admin VLAN VID=2  
Marketing VLAN VID=4  
411  
VLAN-aware  
server  
SWITCH3  
Table 12: VLAN membership of example of a network using tagged ports.  
VLAN  
Member ports  
Training  
3, 26 on Switch A  
21, 22, 25 on Switch B  
Marketing  
Admin  
2, 4, 26 on Switch A  
23, 25 on Switch B  
1, 2 on Switch A  
VLAN Membership of Untagged Packets  
A VLAN that does not send any VLAN-tagged frames is a logical grouping of  
ports. All untagged traffic arriving at those ports belongs to that VLAN.  
VLANs based on untagged ports are limited, because each port can only  
belong to one VLAN as an untagged port. Limitations include:  
It is difficult to share network resources, such as servers and printers,  
across several VLANs. The routing functions in the switch must be  
configured to interconnect using untagged ports only.  
A VLAN that spans several switches requires a port on each switch for the  
interconnection of the various parts of the VLAN. If there are several  
VLANs in the switch that span more than one switch, then many ports are  
occupied with connecting the VLANs, and so are unavailable for other  
devices.  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Layer 2 Switching  
77  
If the network includes VLANs that do not need to share network resources or  
span several switches, VLAN membership can usefully be based on untagged  
ports. Otherwise, VLAN membership should be determined by tagging (see  
Figure 15 on page 77 shows two port-based VLANs with untagged ports  
belonging to them. Ports 1-3 belong to the marketing VLAN, and ports 14-16  
belong to the training VLAN. The switch acts as two separate bridges: one that  
forwards traffic between the ports belonging to the marketing VLAN, and a  
second one that forwards traffic between the ports belonging to the training  
VLAN. Devices in the marketing VLAN can only communicate with devices in  
the training VLAN by using the switch’s routing functions.  
Figure 15: VLANS with untagged ports.  
Port 2  
Port 3  
Port 1  
Marketing VLAN  
Switch  
Training VLAN  
Port 14  
Port 16  
Port 15  
411  
SWITCH2  
Creating VLANs  
To briefly summarise the process of creating a VLAN:  
1. Create the VLAN.  
2. Add tagged ports to the VLAN, if required.  
3. Add untagged ports to the VLAN, if required.  
To create a VLAN, use the command:  
CREATE VLAN=vlan-name VID=2..4094  
Every port must belong to a VLAN, unless it is the mirror port. By default, all  
ports belong to the default VLAN as untagged ports.  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
78  
AT-8800 Series Switch User Guide  
To add tagged ports to a VLAN, use the command:  
ADD VLAN={vlan-name|1..4094} PORT={port-list|ALL}  
FRAME=TAGGED  
A port can be tagged for any number of VLANs.  
To add untagged ports to a VLAN, use the command:  
ADD VLAN={vlan-name|1..4094} PORT={port-list|ALL}  
[FRAME=UNTAGGED]  
A port can be untagged for zero or one VLAN. A port can only be added to the  
default VLAN as an untagged port if it is not untagged for another VLAN. A  
port cannot transmit both tagged and untagged frames for the same VLAN  
(that is, it cannot be added to a VLAN as both a tagged and an untagged port).  
To remove ports from a VLAN, use the command:  
DELETE VLAN={vlan-name|1..4094} PORT={port-list|ALL}  
Removing an untagged port from a VLAN will return it to the default VLAN,  
unless it is a tagged port for another static VLAN. An untagged port can only  
be deleted from the default VLAN if the port is a tagged port for another static  
VLAN.  
Ports tagged for some VLANs and left in the default VLAN as untagged ports will  
transmit broadcast traffic for the default VLAN. If this is not required, the unnecessary  
traffic in the switch can be reduced by deleting those ports from the default VLAN.  
To change the tagging status of a port in a VLAN, use the command:  
SET VLAN={vlan-name|1..4094} PORT={port-list|ALL}  
FRAME=TAGGED  
To destroy a VLAN, use the command:  
DESTROY VLAN={vlan-name|2..4094|ALL}  
VLANs can only be destroyed if no ports belong to them.  
To display the VLANs configured on the switch, use the command:  
SHOW VLAN[={vlan-name|1..4094|ALL}]  
Information which may be useful for trouble-shooting a network can be  
displayed with the VLAN debugging mode. This is disabled by default, and  
can be enabled for a specified time, disabled, and displayed using the  
commands:  
ENABLE VLAN={vlan-name|1..4078|ALL} DEBUG={PKT|ALL}  
[OUTPUT=CONSOLE] [TIMEOUT={1..4000000000|NONE}]  
DISABLE VLAN={vlan-name|1..4078|ALL} DEBUG={PKT|ALL}  
SHOW VLAN DEBUG  
To view packet reception and transmission counters for a VLAN, use the  
command (see the Interfaces chapter of the switch’s Software Reference):  
SHOW INTERFACE=VLANn COUNTER  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Layer 2 Switching  
79  
Summary of VLAN tagging rules  
When designing a VLAN and adding ports to VLANs, the following rules  
apply.  
1. Each port, except for the mirror port, must belong to at least one static  
VLAN. By default, a port is an untagged member of the default VLAN.  
2. A port can be untagged for zero or one VLAN. A port that is untagged for  
a VLAN transmits frames destined for that VLAN without a VLAN tag in  
the Ethernet frame.  
3. A port can be tagged for zero or more VLANs. A port that is tagged for a  
VLAN transmits frames destined for that VLAN with a VLAN tag,  
including the numerical VLAN Identifier of the VLAN.  
4. A port cannot be untagged and tagged for the same VLAN.  
5. The mirror port, if there is one, is not a member of any VLAN.  
Protected VLANs  
If a VLAN is Protected, Layer 2 traffic between ports that are members of a  
Protected VLAN is blocked. Traffic can be Layer 3 switched to another VLAN.  
This feature prevents members of a Protected VLAN from communicating with  
each other yet still allows members to access another network. Layer 3 Routing  
between Ports in a Protected VLAN can be prevented by adding a Layer 3  
filter. The Protected VLAN feature also allows all of the members of the  
Protected VLAN to be in the same subnet.  
A typical application is a hotel installation where each room has a port that can  
be used to access the Internet. In this situation it is undesirable to allow  
communication between rooms.  
To create a Protected VLAN, use the command:  
CREATE VLAN=vlan-name VID=2..4094 [PROTECTED]  
VLAN Interaction with STPs and Trunk Groups  
Each VLAN and port can only belong to one Spanning Tree entity (STP). A port  
cannot be added to a VLAN that is in a different STP from the VLANs to which  
the port already belongs, with one exception. The exception is that an untagged  
port in the default VLAN can be moved from the default VLAN to any other  
VLAN in any STP, if the port belongs only to the default VLAN as an untagged  
port.  
All the ports in a trunk group must have the same VLAN configuration: they  
must belong to the same VLANs and have the same tagging status, and can  
only be operated on as a group.  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
80  
AT-8800 Series Switch User Guide  
Generic VLAN Registration Protocol  
(GVRP)  
The GARP application GVRP allows switches in a network to dynamically  
share VLAN membership information, to reduce the need for statically  
configuring all VLAN membership changes on all switches in a network. See  
the Generic Attribute Registration Protocol (GARP) chapter in the Rapier Switch  
Software Reference.  
Layer 2 Switching Process  
The Layer 2 switching process comprises related but separate processes. The  
Ingress Rules admit or discard frames based on their VLAN tagging. The  
Learning Process learns the MAC addresses and VLAN membership of frames  
admitted on each port. The Forwarding Process determines which ports the  
frames are forwarded to, and the Quality of Service priority with which they are  
transmitted. Finally, the Egress Rules determine for each frame whether VLAN  
tags are included in the Ethernet frames that are transmitted. These processes  
assume that each station on the extended LAN has a unique data link layer  
address, and that all data link layer frames have a header which includes the  
source (sender’s) MAC address and destination (recipient’s) MAC address.  
The Ingress Rules  
When a frame first arrives at a port, the Ingress Rules for the port check the  
VLAN tagging in the frame to determine whether it will be discarded or  
forwarded to the Learning Process.  
The first check depends on whether the Acceptable Frame Types parameter is set  
to Admit All Frames or to Admit Only VLAN Tagged Frames. A port that transmits  
only VLAN tagged frames, regardless of which VLAN the port belongs to, will  
be automatically set to Admit Only VLAN Tagged Frames. The user cannot  
change this setting. Frames with a null numerical VLAN Identifier (VID) are  
VLAN-untagged frames, or frames with priority tagging only.  
Every frame received by the switch must be associated with a VLAN. If a frame  
is admitted by the Acceptable Frame Types parameter, the second part of the  
Ingress Rules associates each untagged frame admitted with the VID of the  
VLAN for which the port is untagged.  
Every port belongs to one or more VLANs, and therefore every incoming  
frame will have a VID to show which VLAN it belongs to. The final part of the  
Ingress Rules depends on whether Ingress Filtering is enabled for the port. If  
Ingress Filtering is disabled, all frames are passed on to the Learning Process,  
regardless of which VLAN they belong to. If Ingress Filtering is enabled,  
frames are admitted only if they have the VID of a VLAN to which the port  
belongs. If they have the VID of a VLAN to which the port does not belong,  
they are discarded.  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Layer 2 Switching  
81  
The default settings for the Ingress Rules are to Admit All Frames, and for  
Ingress Filtering to be OFF. This means that if no VLAN configuration has been  
done, all incoming frames pass on to the Learning Process, regardless of  
whether or not they are VLAN tagged. The parameters for each port’s Ingress  
Rules can be configured using the command:  
SET SWITCH PORT={port-list|ALL} [ACCEPTABLE={VLAN|ALL}]  
[INFILTERING={ON|OFF}] [other-parameters...]  
The ACCEPTABLE parameter sets the Acceptable Frame Types parameter, in  
the Ingress Rules, which controls reception of VLAN-tagged and VLAN-  
untagged frames on the port. If ALL is specified, then the Acceptable Frame  
Types parameter is set to Admit All Frames. If VLAN is specified, the  
parameter is set to Admit Only VLAN-tagged Frames, and any frame received  
that carries a null VLAN Identifier (VID) is discarded by the ingress rules.  
Untagged frames and priority-tagged frames carry a null VID. Untagged  
frames admitted according to the ACCEPTABLE parameter have the VID of the  
VLAN for which the port is untagged associated with them. The  
ACCEPTABLE parameter can only be set if the port is untagged for one VLAN.  
In this case, the default is ALL, admitting all tagged and untagged frames. If  
the port is tagged for all the VLANs to which it belongs, the ACCEPTABLE  
parameter is automatically set to VLAN, and cannot be changed to admit  
untagged frames.  
The INFILTERING parameter enables or disables Ingress Filtering of frames  
admitted according to the ACCEPTABLE parameter, on the specified ports.  
Each port on the switch belongs to one or more VLANs. If INFILTERING is set  
to ON, Ingress Filtering is enabled: any frame received on a specified port is  
only admitted if the port belongs to the VLAN with which the frame is  
associated. Conversely, any frame received on the port is discarded if the port  
does not belong to the VLAN with which the frame is associated. Untagged  
frames admitted by the ACCEPTABLE parameter are admitted, since they have  
the numerical VLAN Identifier (VID) of the VLAN for which the port in an  
untagged member. If OFF is specified, Ingress Filtering is disabled, and no  
frames are discarded by this part of the Ingress Rules. The default setting is  
OFF.  
To display the current Ingress Rules, use the command:  
SHOW SWITCH PORT=port-list  
The Learning Process  
The Learning Process uses an adaptive learning algorithm, sometimes called  
backward learning, to discover the location of each station on the extended LAN.  
All frames admitted by the Ingress Rules on any port are passed on to the  
Forwarding Process if they are for destinations within the same VLAN. Frames  
destined for other VLANs are passed to the layer three protocol, for instance IP.  
For every frame admitted, the frame’s source MAC address and numerical  
VLAN Identifier (VID) are compared with entries in the Forwarding Database  
for the VLAN (also known as a MAC address table, or a forwarding table)  
maintained by the switch. The Forwarding Database contains one entry for  
every unique station MAC address the switch knows in each VLAN.  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
82  
AT-8800 Series Switch User Guide  
If the frame’s source address is not already in the Forwarding Database for the  
VLAN, the address is added and an ageing timer for that entry is started. If the  
frame’s source address is already in the Forwarding Database, the ageing timer  
for that entry is restarted. By default, switch learning is enabled, and it can be  
disabled or enabled using the commands:  
DISABLE SWITCH LEARNING  
ENABLE SWITCH LEARNING  
If the ageing timer for an entry in the Forwarding Database expires before  
another frame with the same source address is received, the entry is removed  
from the Forwarding Database. This prevents the Forwarding Database from  
being filled up with information about stations that are inactive or have been  
disconnected from the network, while ensuring that entries for active stations  
are kept alive in the Forwarding Database. By default, the ageing timer is  
enabled, and it can be disabled or enabled using the commands:  
ENABLE SWITCH AGEINGTIMER  
DISABLE SWITCH AGEINGTIMER  
If switch learning is disabled and the ageing timer has aged out all dynamically learned  
filter entries, only statically entered MAC source addresses will be used to decide which  
packets to forward or discard. If the switch finds no matching entries in the Forwarding  
Database during the Forwarding Process, then all switch ports in the VLAN will be  
flooded with the packet, except the port on which the packet was received.  
The default value of the ageing timer is 300 seconds (5 minutes), and this can  
be modified using the command:  
SET SWITCH AGEINGTIMER=10..1000000  
The Forwarding Database relates a station’s (source) address to a port on the  
switch, and is used by the switch to determine from which port (if any) to  
transmit frames with a destination MAC address matching the entry in the  
station map.  
To display the contents of the Forwarding Database, use the command:  
SHOW SWITCH FDB [ADDRESS=macadd]  
[DISCARD={SOURCE|DESTINATION}] [HIT={YES|NO}]  
[L3={YES|NO}] [PORT={portlist|ALL}]  
[STATUS={STATIC|DYNAMIC}] [VLAN={vlanname|1..4094}]  
To display general switch settings, including settings for switch learning and  
the switch aging timer, use the command:  
SHOW SWITCH  
The Forwarding Process  
The Forwarding Process forwards received frames that are to be relayed to  
other ports in the same VLAN, filtering out frames on the basis of information  
contained in the station map and on the state of the ports. If a frame is received  
on the port for a destination in a different VLAN, it is either Layer 3 switched if  
it is an IP packet, or looked up in the Layer 3 routing tables (see the Rapier  
Switch Software Reference.)  
Forwarding occurs only if the port on which the frame was received is in the  
Spanning Tree ‘Forwarding’ state. The destination address is then looked up in  
the Forwarding Database for the VLAN. If the destination address is not found,  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Layer 2 Switching  
83  
the switch floods the frame on all ports in the VLAN except the port on which  
the frame was received. If the destination address is found, the switch discards  
the frame if the port is not in the STP ‘Forwarding’ state, if the destination  
address is on the same port as the source address, or if there is a static filter  
entry for the destination address set to DISCARD (“Layer 2 Filtering” on  
page 83). Otherwise, the frame is forwarded on the indicated port.  
This whole process can further be modified by the action of static switch filters.  
These are configurable filters which allow switched frames to be checked  
against a number of entries.  
The Forwarding Process provides storage for queued frames to be transmitted  
over a particular port or ports. More than one transmission queue may be  
provided for a given port. Which transmission queue a frame is sent to is  
determined by the user priority tag in the Ethernet frame, and the Quality of  
Service mapping.  
Layer 2 Filtering  
The switch has a Forwarding Database, entries in which determine whether  
frames are forwarded or discarded over each port. Entries in this Forwarding  
Database are created dynamically by the Learning Process. A dynamic entry is  
automatically deleted from the Forwarding Database when its ageing timer  
expires. Filtering is specified in the IEEE 802.1D Standard “Media Access Control  
(MAC) Bridges”.  
The user can configure static switch filter entries using the command line  
interface. Static switch filter entries associate a MAC address with a VLAN and  
a port in the VLAN. When the switch receives a frame with a destination  
address and VLAN Identifier that match those of a static filter entry, the frame  
can be either forwarded to the port specified in the static filter entry, or  
discarded.  
The Forwarding Database supports queries by the Forwarding Process as to  
whether frames with given values of the destination MAC address field should  
be forwarded to a given port.  
To add or delete static switch filter entries, use the commands:  
ADD SWITCH FILTER DESTADDRESS=macadd ACTION={FORWARD|DISCARD}  
PORT[=port-list] [ENTRY=entry] [VLAN={vlanname|1..4094}]  
DELETE SWITCH FILTER ENTRY=entry-list  
The switch automatically deletes static filter entries for a port if the port is deleted from  
the specified VLAN.  
To display current static switch filter entries, use the command:  
SHOW SWITCH FILTER [DESTADDRESS=macadd] [ENTRY=entry]  
[PORT=port-list] [VLAN={vlanname|1..4094}]  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
84  
AT-8800 Series Switch User Guide  
Figure 16: Example output from the SHOW SWITCH FILTER command.  
Switch Filters  
---------------------------------------------------------------------------  
Entry VLAN Destination Address Port Action Source  
---------------------------------------------------------------------------  
0
1
default (1)  
default (1)  
aa-ab-cd-00-00-01  
aa-ab-cd-00-00-02  
1 Forward static  
1 Forward static  
0
1
marketing (2)  
marketing (2)  
aa-ab-cd-00-00-01  
aa-ab-cd-00-00-02  
2 Discard static  
2 Discard learn  
---------------------------------------------------------------------------  
Table 13: Parameters in the output of the SHOW SWITCH FILTER command  
Parameter  
Entry  
Meaning  
The number identifying the filter entry.  
The destination MAC address for the entry.  
The VLAN name and identifier for the entry.  
The outbound port to match for the filter entry to be applied.  
Destination Address  
VLAN  
Port  
Action  
The action specified by the filter entry; one of “Forward” or  
“Discard”.  
Source  
This parameter is either “static” (indicating the filter is a static  
filter) or “learned” (indicating the filter is present either  
because it has been added with the LEARN parameter of the  
SET SWITCH PORT command, or has been dynamically learned  
during normal intrusion detection operation).  
For each VLAN, the destination MAC address of a frame to be forwarded is  
checked against the Forwarding Database. If there is no entry for the  
destination address and VLAN, the frame is transmitted on all ports in the  
VLAN that are in the ‘Forwarding’ or ‘Disabled’ states, except the port on  
which the frame was received. This process is referred to as flooding. If an entry  
is found in the Forwarding Database, but the entry is not marked as  
‘Forwarding’ or the entry points to the same port the frame was received on,  
the frame is discarded. Otherwise, the frame is transmitted on the port  
specified by the entry in the Forwarding Database.  
A dynamic entry is automatically deleted from the Forwarding Database when  
its ageing timer expires.  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Layer 2 Switching  
85  
The Egress Rules  
Once the Forwarding Process has determined which ports and transmission  
queues to forward a frame from, the Egress Rules for each port determine  
whether or not the outgoing frame is VLAN-tagged with its numerical VLAN  
When a port is added to a VLAN, it is configured to transmit either untagged  
or VLAN tagged packets, using the command:  
ADD VLAN={vlanname|1..4094} PORT={port-list|ALL}  
[FRAME={TAGGED|UNTAGGED}]  
This setting can be changed for a port which is already part of a VLAN, using  
the command:  
SET VLAN={vlanname|1..4094} PORT={port-list|ALL}  
FRAME={UNTAGGED|TAGGED}  
Quality of Service  
The switch hardware has a number of Quality of Service (QOS) egress queues  
that can be used to give priority to the transmission of some frames over other  
frames on the basis of their user priority tagging. The user priority field in an  
incoming frame (with value 0 to 7) determines which of the eight priority levels  
the frame is allocated. When a frame is forwarded, it is sent to a QOS egress  
queue on the port determined by the mapping of priority levels to QOS egress  
queues. All frames in the first QOS queue are sent before any frames in the  
second QOS egress queue, and so on, until frames in the last QOS egress queue,  
which are only sent when there are no frames waiting to be sent in any of the  
higher QOS egress queues.  
The mapping between user priority and a QOS egress queue can be configured  
using the command:  
SET SWITCH QOS=P0,P1,P2,P3,P4,P5,P6,P7  
The switch has four QOS egress queues. It has a default mapping of priority  
levels to QOS egress queues as defined in IEEE Standard 802.1Q (Table 14).  
Table 14: Default priority level to queue mapping for four QOS egress queues  
Priority level  
QOS Egress Queue  
0
1
2
3
4
5
6
7
1
0
0
1
2
2
3
3
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
86  
AT-8800 Series Switch User Guide  
To display the mapping of user priority to QOS egress queues, use the  
command:  
SHOW SWITCH QOS  
Figure 17: Example output from the SHOW SWITCH QOS command  
Priority Level QOS egress queue  
-------------------------------------  
0 ................... 1  
1 ................... 0  
2 ................... 0  
3 ................... 1  
4 ................... 2  
5 ................... 2  
6 ................... 3  
7 ................... 3  
Table 15: Parameters in the output of the SHOW SWITCH QOS command  
Parameter  
Meaning  
Priority level  
The priority level of the frame.  
QOS egress queue  
The Quality Of Service egress queue that frames with this  
priority level join.  
Spanning Tree Protocol (STP)  
The Spanning Tree Protocol (STP) makes it possible to automatically disable  
redundant paths in a network to avoid loops, and enable them when a fault in  
the network means they are needed to keep traffic flowing. A sequence of  
LANs and switches may be connected together in an arbitrary physical  
topology resulting in more than one path between any two switches. If a loop  
exists, frames transmitted onto the extended LAN would circulate around the  
loop indefinitely, decreasing the performance of the extended LAN. On the  
other hand, multiple paths through the extended LAN provide the opportunity  
for redundancy and backup in the event of a bridge experiencing a fatal error  
condition.  
The spanning tree algorithm ensures that the extended LAN contains no loops  
and that all LANs are connected by:  
Detecting the presence of loops and automatically computing a logical  
loop-free portion of the topology, called a spanning tree. The topology is  
dynamically pruned to a spanning tree by declaring the ports on a switch  
redundant, and placing the ports into a ‘Blocking’ state.  
Automatically recovering from a switch failure that would partition the  
extended LAN by reconfiguring the spanning tree to use redundant paths,  
if available.  
Spanning Tree Modes  
STP can run in STANDARD mode, or RAPID mode. Rapid mode allows for  
rapid configuration of the spanning tree. The Rapid Spanning Tree Protocol  
(RSTP) is specified in IEEE 802.1w.  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Layer 2 Switching  
87  
A spanning tree running in standard mode can take up to one minute to rebuild  
after a topology or configuration change. The Rapid Spanning Tree algorithm  
provides for a more rapid recovery of connectivity following the failure of a  
bridge, bridge port, or a LAN.  
For information about RSTP see the Rapid Mode Spanning Tree Types section,  
Switch chapter in the Rapier Switch Software Reference.  
Spanning Tree and Rapid Spanning Tree Port States  
If STP is running in STANDARD mode, then each port can be in one of five  
Spanning Tree states, and one of two switch states. If STP is running in RAPID  
mode, then each port can be in one of four states. The state of a switch port is  
taken into account by STP. To be involved in STP negotiations, STP must be  
enabled on the switch, the port must be enabled on the switch, and enabled for  
the STP it belongs to.  
The Spanning Tree states (see Table 16) affect the behaviour of ports whose  
switch state is enabled.  
Table 16: Spanning tree port states .  
State  
Meaning  
DISABLED  
STP operations are disabled on the port. The port can still  
switch if its switch state is enabled.  
LISTENING  
LEARNING  
The port is enabled for receiving frames only.  
The port is enabled for receiving frames only, and the  
Learning Process can add new source address information  
to the Forwarding Database.  
FORWARDING  
BLOCKING  
The normal state for a switch port. The Forwarding Process  
and the Spanning Tree entity are enabled for transmit and  
receive operations on the port.  
The Spanning Tree entity has disabled the Forwarding  
process for transmit and receive operations on the port, but  
the Spanning Tree entity itself remains enabled for transmit  
and receive operations on the port.  
Table 17: Rapid Spanning Tree port states .  
State  
Meaning  
DISABLED  
DISCARDING  
STP operations are disabled on the port.  
The port does not participate in frame relay. The forwarding  
process discards received frames and does not submit  
forwarded frames for transmission.  
LEARNING  
The port is enabled for receiving frames only, and the  
Learning Process can add new source address information  
to the Forwarding Database. The port does not forward any  
frames.  
FORWARDING  
The normal state for a switch port. The Forwarding Process  
and the Spanning Tree entity are enabled for transmit and  
receive operations on the port.  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
88  
AT-8800 Series Switch User Guide  
To specify whether the STP will operate in STANDARD mode or RAPID mode,  
use the command:  
SET STP={stp-name|ALL} [MODE={STANDARD|RAPID}] [other  
parameters]  
The default is STANDARD. If the mode is changed while the algorithm is  
running then the STP is re-initialised.  
To display the STP state of the switch ports (Figure 19 on page 94), use the  
command:  
SHOW STP[={stp-name|ALL}] PORT={port-list|ALL}  
A Rapier switch in default LAN configuration has a default Spanning Tree  
enabled, spanning only a single default VLAN, to which all ports belong. The  
switches in the LAN run a distributed Spanning Tree Algorithm to create a  
single Spanning Tree. In a network of Rapier switches with VLANs configured,  
all VLANs belong by default to a default Spanning Tree called default. Multiple  
Spanning Trees can be created with each Spanning Tree encompassing multiple  
VLANs (in networks switched exclusively by Rapier switches).  
For more information about multiple spanning trees, see the Switching chapter  
in the Rapier Switch Software Reference.  
Configuring STP  
By default, the switch has one default STP which cannot be destroyed. In most  
situations this default STP will suffice.  
By default, all VLANs, and therefore all ports, belong to the default STP. To add  
or delete a VLAN and all the ports belonging to it from any other STP, use the  
commands:  
ADD STP=stpname VLAN={vlan-name|2..4094}  
DELETE STP=stpname VLAN={vlan-name|2..4094|ALL}  
The default STP is disabled by default at switch start up, and STPs created by a  
user are disabled by default when they are created. An STP must be enabled  
before STP can be enabled or disabled on particular ports belonging to it. To  
enable or disable STPs, use the commands:  
ENABLE STP{=stpname|ALL}  
DISABLE STP={stpname|ALL}  
The Spanning Tree Protocol uses three configurable parameters for the time  
intervals that control the flow of STP information on which the dynamic STP  
topology depends: the HELLOTIME, FORWARDDELAY and MAXAGE  
parameters. All switches in the same spanning tree topology must use the same  
values for these parameters, but can themselves be configured with different,  
and potentially incompatible time intervals. The parameter values actually  
used by each switch are those sent by the root bridge, and forwarded to all  
other switches by the designated bridges.  
The FORWARDDELAY parameter sets the time, in seconds, used to control  
how fast a port changes its spanning state when moving towards the  
Forwarding state. The value determines how long the port stays in each of the  
Listening and Learning states which precede the Forwarding state. This value  
is only used when the switch is acting as the Root Bridge. Any switch not  
acting as the Root Bridge uses a dynamic value for the FORWARDDELAY set  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Layer 2 Switching  
89  
by the Root Bridge. The FORWARDDELAY, MAXAGE and HELLOTIME  
parameters are interrelated. See the note and formulae below. The default  
value for FORWARDDELAY is 15 seconds.  
The HELLOTIME parameter sets the time, in seconds, between the  
transmission of switch spanning tree configuration information when the  
switch is the Root Bridge of the spanning tree or is trying to become the Root  
Bridge. The default value is 2 seconds.  
The MAXAGE parameter sets the maximum age, in seconds, of Spanning Tree  
Protocol information learned over the network on any port before it is  
discarded. The default value is 20 seconds.  
The FORWARDDELAY, MAXAGE and HELLOTIME parameters should be set  
according to the following formulae, as specified in IEEE Standard 802.1D:  
2 x (FORWARDDELAY - 1.0 seconds) >= MAXAGE  
MAXAGE >= 2 x (HELLOTIME + 1.0 seconds)  
To modify the parameters controlling these time intervals, use the command:  
SET STP={stp-name|ALL} [FORWARDDELAY=4..30] [HELLOTIME=1..10]  
[MAXAGE=6..40] [other parameters]  
The value of the PRIORITY parameter is used to set the writable portion of the  
bridge ID, i.e. the first two octets of the (8-octet long) Bridge Identifier. The  
remaining 6 octets of the bridge ID are given by the MAC address of the  
switches. The Bridge Identifier parameter is used in all configuration Spanning  
Tree Protocol packets transmitted by the switch. The first two octets, specified  
by the PRIORITY parameter, determine the switch’s priority for becoming the  
root bridge or a designated bridge in the network, with a lower number indicating  
a higher priority. In fairly simple networks, for instance those with a small  
number of switches in a meshed topology, it may make little difference which  
switch is selected to be the root bridge, and no modifications may be needed to  
the default PRIORITY parameter, which has a default value of 32768. In more  
complex networks, one or more switches are likely to be more suitable  
candidates for the root bridge role, for instance by virtue of being more central  
in the physical topology of the network. In these cases the STP PRIORITY  
parameters for at least one of the switches should be modified.  
To change the STP priority value, use the command:  
SET STP={stpname|ALL} PRIORITY=0..65535  
The PRIORITY parameter sets the priority of the switch to become the Root  
Bridge. The lower the value of the Bridge Identifier, the higher the priority. If  
the PRIORITY parameter is set, either by specifying the PRIORTY or DEFAULT  
parameters, the specified STP is initialised. Counters for the STP are not  
affected. The default value for PRIORITY is 32768.  
To restore STP timer and priority defaults, use the command:  
SET STP={stpname|ALL} DEFAULT  
Changing the STP PRIORITY using either of the previous commands initialises  
the STP, so that elections for the root bridge and designated bridges begin  
again, without resetting STP counters. To display general information about  
STPs on the switch, use the command:  
SHOW STP[={stpname|ALL}] [SUMMARY]  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
90  
AT-8800 Series Switch User Guide  
Figure 18: Example output from the SHOW STP command.  
STP Information  
------------------------------------------------------------  
Name .................. grey  
Mode .................. Rapid  
RSTP Type ............. Normal  
VLAN members .......... vlan4 (4)  
Status ................ ON  
Number of Ports ....... 2  
Number Enabled ...... 2  
Number Disabled ..... 0  
Bridge Identifier ..... 32768 : 00-00-cd-05-19-28  
Bridge Priority ....... 32768  
Root Bridge ........... 32768 : 00-00-cd-05-19-28  
Designated Bridge ..... 32768 : 00-00-cd-05-19-28  
Root Port ............. (n/a)  
Root Path Cost ........ 0  
Max Age ............... 20  
Hello Time ............ 2  
Forward Delay ......... 15  
Switch Max Age ........ 20  
Switch Hello Time ..... 2  
Switch Forward Delay .. 15  
Transmission Limit .... 3  
Name .................. default  
Mode .................. Standard  
RSTP Type ............. (n/a)  
VLAN members .......... default (1)  
vlan5 (5)  
vlan6 (6)  
vlan7 (7)  
vlan8 (8)  
vlan9 (9)  
vlan10 (10)  
vlan11 (11)  
vlan12 (12)  
vlan13 (13)  
vlan14 (14)  
Status ................ OFF  
Number of Ports ....... 22  
Number Enabled ...... 0  
Number Disabled ..... 22  
Bridge Identifier ..... 32768 : 00-00-cd-05-19-28  
Bridge Priority ....... 32768  
Designated Root ....... 32768 : 00-00-cd-05-19-28  
Root Port ............. (n/a)  
Root Path Cost ........ 0  
Max Age ............... 20  
Hello Time ............ 2  
Forward Delay ......... 15  
Switch Max Age ........ 20  
Switch Hello Time ..... 2  
Switch Forward Delay .. 15  
Hold Time ............. 1  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Layer 2 Switching  
91  
Table 18: Parameters in the output of the SHOW STP command .  
Parameter  
STP Name  
Mode  
Meaning  
The name of the Spanning Tree Protocol entity.  
Whether STP is running in standard, or rapid mode.  
RSTP Type  
Whether RSTP is operating normally, or as STP compatible.  
In STP compatible mode, the rapid transitions to forwarding  
do not occur.  
VLAN members  
A list of the VLANs that are members of the STP. VLAN  
Identifiers are shown in brackets.  
Status  
The status of the STP; either ON or OFF.  
The number of ports belonging to the STP.  
Number of Ports  
Number Enabled  
The number of ports that have been enabled using the  
ENABLE STP command and are being considered by the  
Spanning Tree Algorithm.  
Number Disabled  
Bridge Identifier  
The number of ports that have been disabled using the  
DISABLE STP command and are not being considered by the  
Spanning Tree Algorithm.  
The unique Bridge Identifier of the switch. This parameter  
consists of two parts, one of which is derived from the  
unique Switch Address, and the other of which is the  
priority of the switch.  
Bridge Priority  
The settable priority component that permits the relative  
priority of bridges to be managed. The range of values is  
between 0 and 65535. A lower number indicates a higher  
priority.  
Designated Root  
Root Bridge  
The unique Bridge Identifier of the bridge assumed to be  
the root, (Standard Mode only).  
The unique Bridge Identifier of the bridge assumed to be  
the Root, (Rapid Mode only).  
Designated Bridge  
The unique Bridge Identifier of the bridge assumed to be  
the designated bridge. Displayed when STP is set to RAPID  
mode, (Rapid Mode only).  
Root Port  
The port number of the root port for the switch. If the  
switch is the Root Bridge this parameter is not valid, and  
(n/a) is shown.  
Root Path Cost  
The cost of the path to the Root from this switch. If the  
switch is the Root Bridge this parameter is not valid and is  
not shown.  
Max Age  
The maximum age of received Configuration Message  
information before it is discarded.  
Hello Time  
The time interval between successive transmissions of the  
Configuration Message information by a switch which is  
the Root or which is attempting to become the Root.  
Forward Delay  
In STP Standard mode, the time ports spend in the Listening  
state before moving to the Learning state and the Learning  
state before moving to the Forwarding state. In Rapid  
mode, the maximum time taken to transition from  
Discarding to Learning and Learning to Forwarding. In both  
modes, the value is also used for the ageing timer for the  
dynamic entries in the Forwarding Database.  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
92  
AT-8800 Series Switch User Guide  
Table 18: Parameters in the output of the SHOW STP command (Continued).  
Parameter  
Meaning  
Switch Max Age  
The value of the Max Age parameter when this switch is the  
Root or is attempting to become the Root. This parameter  
is set by the MAXAGE parameter in the SET STP command.  
Switch Hello Time  
Switch Forward Delay  
Hold Time  
The value of the Hello Time parameter when this switch is  
the Root or is attempting to become the Root. This  
parameter is set by the HELLOTIME parameter in the SET  
STP command.  
The value of the Forward Delay parameter when this switch  
is the Root or is attempting to become the Root. This  
parameter is set by the FORWARDDELAY parameter in the  
SET STP command.  
The minimum time in seconds between the transmission of  
configuration BPDUs through a given LAN Port. The value  
of this fixed parameter is 1, as specified in IEEE 802.1d. This  
parameter applies only to STP running in standard mode.  
Transmission Limit  
In Rapid mode, this indicates the number of BPDUs that  
may be transmitted in the interval specified by Hello Time.  
The value of this fixed parameter is 3, as specified in IEEE  
802.1t.  
The various parameters used by the Spanning Tree Algorithm for the specified  
ports, or all ports within the specified STP, or all STPs, are set with the SET STP  
PORT command:  
SET STP={stp-name|ALL} PORT={port-list|ALL}  
A port can belong to a single STP. This means that if the port is member of  
multiple VLANs then all those VLANs must belong to the same STP.  
The STP parameter specifies an STP name. If no parameter is entered, the  
default value is ALL.  
The PORT parameter specifies a list of ports that can belong to any STP. The  
default value is ALL.  
Each port has a port priority, with a default value of 128, used to determine  
which port should be the root port for the STP if two ports are connected in a  
loop. The lower number indicates the higher priority.  
SET STP={stp-name|ALL} PORT={port-list|ALL}  
PORTPRIORITY=0..255 [other-parameters]  
The PORTPRIORITY parameter sets the value of the priority field contained in  
the port identifier. The Spanning Tree Algorithm uses the port priority when  
determining the root port for each switch. The port with the lowest value is  
considered to have the highest priority. The default value is 128. Each STP has  
its own independent PORTPRIORITY parameter for each member port.  
Each port also has a path cost, which is used if the port is the root port for the  
STP on the switch. The path cost is added to the root path cost field in  
configuration messages received on the port to determine the total cost of the  
path to the root bridge. The default PATHCOST values depend on the port  
speed, according to the formula:  
PATHCOST = 1000 / Port_Speed_in_MB_per_second  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Layer 2 Switching  
93  
so that a port operating at 10Mbps has a default pathcost of 100, a port  
operating at 100 Mbps has a default pathcost of 10, and a port operating at 1  
Gbps has a default pathcost of 1. Setting the pathcost to a larger value on a  
particular port is likely to reduce the traffic over the LAN connected to it. This  
may be appropriate if the LAN has lower bandwidth, or if there are reasons for  
limiting the traffic across it. To modify the STP port pathcost, use the  
command:  
SET STP={stp-name|ALL} PORT={port-list|ALL}  
PATHCOST=1..1000000  
If the PATHCOST of a port has not been explicitly set by the user, or the default  
values have been restored to the port, then the default PATHCOST for the port  
will vary as the speed of the port varies.  
The default value for PATHCOST is set according to the speed. For a port  
operating at 100 Mbps, the default value is 19. For a port operating at 10 Mbps,  
the default value is 100.  
To restore default port pathcost and priority, use the command:  
SET STP={stp-name|ALL} PORT={port-list|ALL} DEFAULT  
When an STP is enabled in a looped or meshed network, it disables and  
enables particular ports belonging to it dynamically, to eliminate redundant  
links. All ports in a VLAN belong to the same STP, and their participation in  
STP configuration, and hence the possibility of them being elected to the STP’s  
active topology is enabled by default. To enable or disable particular ports, use  
the commands:  
ENABLE STP PORT={port-list|ALL}  
DISABLE STP PORT={port-list|ALL}  
To display STP port information, use the command:  
SHOW STP[={stp-name|ALL}] PORT={port-list|ALL}  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
94  
AT-8800 Series Switch User Guide  
Figure 19: Example output from the SHOW STP PORT command.  
STP Port Information  
------------------------------------------------------------  
STP ..................... grey  
STP Status ............ ON  
Port .................. 3  
RSTP Port Role ...... Disabled  
State ............... Discarding  
Point To Point ...... No (Auto)  
Port Priority ....... 128  
Port Identifier ..... 8003  
Pathcost ............ 200000  
Designated Root ..... 32768 : 00-00-cd-05-19-28  
Designated Cost ..... 0  
Designated Bridge ... 32768 : 00-00-cd-05-19-28  
Designated Port ..... 8003  
EdgePort ............ No  
VLAN membership ..... 1  
Port .................. 4  
RSTP Port Role ...... Disabled  
State ............... Discarding  
Point To Point ...... No (Auto)  
Port Priority ....... 128  
Port Identifier ..... 8004  
Pathcost ............ 200000  
Designated Root ..... 32768 : 00-00-cd-05-19-28  
Designated Cost ..... 0  
Designated Bridge ... 32768 : 00-00-cd-05-19-28  
Designated Port ..... 8004  
EdgePort ............ No  
STP ..................... default  
STP Status ............ OFF  
Port .................. 1  
State ............... Disabled  
Port Priority ....... 128  
Port Identifier ..... 8001  
Pathcost ............ 19  
Designated Root ..... 32768 : 00-00-cd-05-19-28  
Designated Cost ..... 0  
Designated Bridge ... 32768 : 00-00-cd-05-19-28  
Designated Port ..... 8001  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Layer 2 Switching  
95  
Table 19: Parameters displayed in the output of the SHOW STP PORT command .  
Parameter  
STP  
Meaning  
The name of the STP that the port is a member of.  
STP Status  
Port  
Whether this STP is enabled or disabled; one of ON or OFF.  
The number of the port.  
RSTP Port Role  
The role of the port; one of Disabled, Alternate, Backup,  
Designated, or Root. (Rapid Mode only).  
State  
The state of the port; one of “Disabled”, “Blocking”,  
“Listening”, “Learning” or “Forwarding” for Standard  
mode, and one of; “Disabled”, “Discarding”, “Learning”,  
or “Forwarding” for Rapid mode.  
Point To Point  
Port Priority  
Whether the port has a point to point connection with  
another bridge; one of NO or YES. (Rapid Mode only).  
The priority of the port. Used as part of the Port Identifier  
field. In Standard mode it forms the upper 8 bits of the Port  
Identifier field. In Rapid mode it forms the upper 4 bits of  
the Port Identifier field.  
Port Identifier  
The unique identifier of the port. This parameter is used to  
determine the root port or designated port of the switch.  
Pathcost  
The path cost of the port.  
Designated Root  
The unique Bridge Identifier of the Root Bridge, as recorded  
in the configuration BPDU.  
Designated Cost  
The Designated Cost for the port.  
Designated Bridge  
Either the unique Bridge Identifier of the switch, or the  
unique Bridge Identifier of the switch believed to be the  
Designated Bridge for the LAN to which the port is  
attached.  
Designated Port  
Edge Port  
The Port Identifier of the port on the Designated Bridge  
through which the Designated Bridge transmits  
Configuration BPDU information stored by this port.  
An edge port is a port that attaches to a LAN that is known  
to have no other bridges attached; one of YES, or NO.  
The spanning tree algorithm can be recalculated at any time, and all timers and  
counters be initialised, using the command:  
RESET STP={stpname|ALL}  
To show STP counters, use the command:  
SHOW STP[={stpname|ALL}] COUNTER  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
96  
AT-8800 Series Switch User Guide  
Figure 20: Example output from the SHOW STP COUNTER command  
STP Counters  
------------------------------------------------------------  
STP Name: default  
Receive:  
Transmit:  
Total STP Packets  
Configuration BPDU  
TCN BPDU  
0
0
0
Total STP Packets  
Configuration BPDU  
TCN BPDU  
1677  
0
0
RST BPDU  
0
RSTP BPDU  
1677  
Invalid BPDU  
0
Discarded:  
Port Disabled  
Invalid Protocol  
Invalid Type  
Invalid Message Age  
Config BPDU length  
TCN BPDU length  
RST BPDU length  
0
0
0
0
0
0
0
------------------------------------------------------------  
Table 20: Parameters in the output of the SHOW STP COUNTER command .  
Parameter  
STP Name  
Meaning  
The name of the STP.  
STP packets received.  
Receive  
Total STP Packets  
The total number of STP packets received. Valid STP  
packets comprise Configuration BPDUs and Topology  
Change Notification (TCN) BPDUs.  
Configuration BPDU  
TCN BPDU  
The number of valid Configuration BPDUs received.  
The number of valid Topology Change Notification BPDUs  
received.  
RST BPDU  
The number of valid Rapid Spanning Tree BPDUs received  
(RAPID mode only).  
Invalid BPDU  
The number of invalid STP packets received.  
STP packets transmitted.  
Transmit  
Total STP packets  
Configuration BPDU  
TCN BPDU  
The total number of STP packets transmitted.  
The number of Configuration BPDUs transmitted.  
The number of Topology Change Notification BPDUs  
transmitted.  
RST BPDU  
The number of valid Rapid Spanning Tree BPDUs  
transmitted (RAPID mode only).  
STP packets discarded.  
Discarded  
Port Disabled  
The number of BPDUs discarded because the port that the  
BPDU was received on was disabled.  
Invalid Protocol  
The number of STP packets that had an invalid Protocol  
Identifier field or invalid Protocol Version Identifier field.  
Invalid Type  
The number of STP packets that had an invalid Type field.  
Invalid Message Age  
The number of STP packets that had an invalid message  
age.  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Layer 2 Switching  
97  
Table 20: Parameters in the output of the SHOW STP COUNTER command  
Parameter  
Meaning  
Config BPDU length  
The number of Configuration BPDUs that had an incorrect  
length.  
TCN BPDU length  
RST BPDU length  
The number of Topology Change Notification BPDUs that  
had an incorrect length.  
The number of Rapid Spanning Tree BPDUs that had an  
incorrect length (RAPID mode only).  
If necessary, all the STP configuration that users have created on the switch can  
be removed, so that all STPs except the default STP are destroyed, and all other  
defaults are restored, using the command:  
PURGE STP  
The PURGE STP command should be used with caution, and generally only  
before major reconfiguration of the switch, as it removes all STP configuration  
entered on the switch.  
Interfaces to Layer 3 Protocols  
Interfaces can be configured to VLANs for IP, IPX and Appletalk routing  
protocols in the same way that other interfaces are created for other interface  
types. Concatenate VLAN with the VID of the VLAN giving VLANn, for  
instance:  
INTERFACE=VLAN3  
IGMP Snooping  
IGMP (Internet Group Management Protocol) is used by IP hosts to report their  
multicast group memberships to routers and switches. IP hosts join a multicast  
group to receive broadcast messages directed to the multicast group address.  
IGMP is an IP-based protocol and uses IP addresses to identify both the  
multicast groups and the host members. For a VLAN-aware devices, this  
means multicast group membership is on a per-VLAN basis. If at least one port  
in the VLAN is a member of a multicast group, by default multicast packets  
will be flooded onto all ports in the VLAN.  
IGMP snooping enables the switch to forward multicast traffic intelligently on  
the switch. The switch listens to IGMP membership reports, queries and leave  
messages to identify the switch ports that are members of multicast groups.  
Multicast traffic will only be forwarded to ports identified as members of the  
specific multicast group.  
IGMP snooping is performed at Layer 2 on VLAN interfaces automatically. By  
default, the switch will only forward traffic out those ports with multicast  
listeners, therefore it will not act as a simple hub and flood all multicast traffic  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
98  
AT-8800 Series Switch User Guide  
out all ports. IGMP snooping is independent of the IGMP and Layer 3  
configuration, so an IP interface does not have to be attached to the VLAN, and  
IGMP does not have to be enabled or configured.  
IGMP snooping is enabled by default. To disable it, use the command:  
DISABLE IGMPSNOOPING  
Disabling IGMP snooping may be useful if filters are used extensively, because  
IGMP snooping uses a Layer 3 filter. When IGMP snooping is disabled, this  
filter becomes available. See “Hardware Packet Filters” in the Switching chapter  
of your Software Reference for information about filters. Note that multicast  
packets will flood the VLAN when IGMP snooping is disabled.  
IGMP is used in conjunction with limited static multicast settings, or with  
DVMRP or PIM Sparse Mode for full multicast support (IP Multicasting chapter  
in the Rapier Switch Software Reference).  
IGMP is enabled and disabled using the commands:  
ENABLE IP IGMP  
DISABLE IP IGMP  
IGMP snooping is then enabled or disabled on a VLAN using the commands:  
ENABLE IP IGMP INTERFACE=interface [DLC=1..1024]  
DISABLE IP IGMP INTERFACE=interface [DLC=1..1024]  
The switch will snoop IGMP packets transiting the VLAN and only forward  
multicast packets to the ports which have seen a membership report from  
network devices connected to those ports, instead of being forwarded to all  
ports belonging to the VLAN.  
The command:  
SET IP IGMP TIMEOUT=1..65535 QUERYINTERVAL=1..65535  
sets operational parameters for IGMP. The QUERYINTERVAL parameter  
specifies the time interval, in seconds, at which IGMP Host Membership  
Queries are sent if this switch is elected the designated router for the LAN. The  
default is 125.  
The TIMEOUT parameter specifies the longest interval, in seconds, that a  
group will remain in the local group database without receiving a Host  
Membership Report. The default is 270. If a value is specified for  
QUERYINTERVAL without specifying a value for TIMEOUT, TIMEOUT is  
calculated as 2*(QUERYINTERVAL + 10). The 10 seconds is the variation that  
hosts use when sending Host Membership Reports. If a timeout interval is  
specified, it will override any calculated value.  
The command:  
SHOW IP IGMP [COUNTER] [INTERFACE=interface]  
displays information about IGMP, IGMP snooping, and multicast group  
membership for each VLAN-based IP interface (Figure 21, Table 21 on  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Layer 2 Switching  
99  
Figure 21: Example output from the SHOW IP IGMP command.  
IGMP Protocol  
----------------------------------------------------------------------------------  
Status ........................... Enabled  
Default Query Interval ........... 125 secs  
Default Timeout Interval ......... 270 secs  
Last Member Query Interval ....... 10 (1/10secs)  
Last Member Query Count .......... 2  
Robustness Variable .............. 2  
Query Response Interval .......... 100 (1/10secs)  
Interface Name .......... vlan1  
Other Querier timeout ... 164 secs  
IGMP Proxy .............. Upstream  
Group List ..............  
(DR)  
Group. 224.0.1.22  
Ports 24  
Last Adv. 10.194.254.254  
Last Adv. 10.116.2.1  
Refresh time 184 secs  
Refresh time 254 secs  
All Groups  
Ports 24  
Table 21: Parameters in the output of the SHOW IP IGMP command .  
Parameter  
Meaning  
Status  
The status of IGMP; one of “Enabled” or “Disabled”.  
Default Query Interval  
The default interval at which Host Membership Queries are  
sent.  
Default Timeout Interval  
Last Member Query Interval  
Last Member Query Count  
The default interval after which entries will be removed  
from the group database, if no Host Membership Report is  
received.  
Max Response Time inserted into Group-Specific Queries  
sent in response to Leave Group messages, and is also the  
amount of time between Group-Specific Query messages.  
The number of Group-Specific Queries sent before the  
switch assumes there are no local members.  
Robustness Variable  
IGMP is robust to (Robustness Variable-1) packet losses.  
Query Response Interval  
The Max Response Time (in 1/10 secs) inserted into the  
periodic General Queries.  
Interface Name  
The name of an interface configured for IGMP.  
Other Querier timeout  
The length of time that remains before a multicast router  
decides that there is no longer another multicast router  
which should be the querier.  
IGMP Proxy  
The status of IGMP Proxy; one of “Off”, “Upstream” or  
“Downstream”.  
A list of multicast group memberships for this interface.  
The group multicast address.  
Group List  
Group  
Last Adv.  
Refresh time  
The last host to advertise the membership report.  
The time interval (in seconds) until the membership group  
will be deleted if it does not receive another membership  
report before then.  
Ports  
The list of ports listening to this group.  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
100  
AT-8800 Series Switch User Guide  
Triggers  
The Trigger Facility can be used to automatically run specified command  
scripts when particular triggers are activated. When a trigger is activated by an  
event, global parameters and parameters specific to the event are passed to the  
script that is run. For a full description of the Trigger Facility, see the Trigger  
Facility chapter in the Rapier Switch Software Reference.  
The switch can generate triggers to activate scripts when a fibre uplink port  
loses or gains coherent light. To create or modify a switch trigger, use the  
commands:  
CREATE TRIGGER=trigger-id MODULE=SWITCH  
EVENT={LIGHTOFF|LIGHTON} PORT=port [AFTER=hh:mm]  
[BEFORE=hh:mm] [DATE=date|DAYS=day-list] [NAME=name]  
[REPEAT={YES|NO|ONCE|FOREVER|count}] [SCRIPT=filename...]  
[STATE={ENABLED|DISABLED}] [TEST={YES|NO|ON|OFF}]  
SET TRIGGER=trigger-id PORTS={port-list|ALL} [AFTER=hh:mm]  
[BEFORE=hh:mm] [DATE=date|DAYS=day-list] [NAME=name]  
[REPEAT={YES|NO|ONCE|FOREVER|count}]  
[TEST={YES|NO|ON|OFF}]  
The following sections list the events that may be specified for the EVENT  
parameter, the parameters that may be specified as module-specific-parameters,  
and the arguments passed to the script activated by the trigger.  
Event LINKDOWN  
Description The port link specified by the PORT parameter has just gone down.  
Parameters The following command parameter(s) must be specified in the CREATE/SET  
TRIGGER commands:  
Parameter  
Description  
PORT=port  
The port on which the event will activate the trigger.  
Script Parameters The trigger passes the following parameter(s) to the script:  
Argument  
Description  
%1  
The port number of the port which has just gone down.  
Event LINKUP  
Description The port link specified by the PORT parameter has just come up.  
Parameters The following command parameter(s) must be specified in the CREATE/SET  
TRIGGER commands:  
Parameter  
Description  
PORT=port  
The port on which the event will activate the trigger.  
Script Parameters The trigger passes the following parameter(s) to the script:  
Argument  
Description  
%1  
The port number of the port which has just come up.  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Chapter 6  
Layer 3  
The AT-8800 Series Switch routes IP and IP multicasting traffic at wire speed  
between VLANs, and supports a number of other Layer 3 protocols. Once a  
the VLAN name can be used wherever a logical interface is required in  
commands for configuring routing protocols.  
VLAN names are of the form:  
VLAN-vlanname  
or  
VLANn  
where vlanname is the manager-assigned name of the VLAN, and n is the  
VLAN identifier (VID).  
For example, to create a VLAN called “admin” with a VID of 11, and add port 3  
to it, use the commands:  
CREATE VLAN=admin VID=11  
ADD VLAN=11 PORT=3  
The following names can be used to identify this VLAN in routing commands:  
vlan-admin  
vlan11  
The following sections illustrate the use of VLANs for IP, RIP, IPX, AppleTalk  
and RSVP. For a complete description of all the protocols supported by the  
switch, see the Rapier Switch Software Reference.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
102  
AT-8800 Series Switch User Guide  
Internet Protocol (IP)  
The switch performs IP routing at wire speed between VLANs that have been  
configured as IP interfaces. For example, to add the admin VLAN as an IP  
interface, giving it an IP address of 192.168.163.39 in the subnet 192.168.163.0,  
first enable IP using the command:  
ENABLE IP  
Then use either of the following commands:  
ADD IP INTERFACE=vlan-admin IPADDRESS=192.168.163.39  
MASK=255.255.255.0  
ADD IP INTERFACE=vlan11 IPADDRESS=192.168.163.39  
MASK=255.255.255.0  
The command:  
SHOW IP INTERFACE  
displays the interfaces enabled for IP routing (Figure 22).  
Figure 22: Example output from the SHOW IP INTERFACE command.  
Interface  
Pri. Filt  
Type  
IP Address  
Bc Fr PArp Filt RIP Met. SAMode IPSc  
MTU VJC GRE OSPF Met. DBcast Mul.  
Pol.Filt Network Mask  
--------------------------------------------------------------------------------  
LOCAL  
---  
vlan11  
---  
ppp1  
---  
-
----  
Not Set  
-
- n -  
--- -  
--- -  
--- 01  
--- 0000000001 No  
--- 01 Pass  
-
-
Pass  
--  
---  
--  
On  
--  
On  
-
-
Static 192.168.163.39 1 y On  
---  
Dynamic 0.0.0.0  
---  
255.255.255.0  
1500 -  
1 y -  
255.255.255.255 1500 Off --- 0000000001 No  
--------------------------------------------------------------------------------  
IP Multicasting  
Static multicast forwarding can be configured using the ADD IP INTERFACE  
or SET IP INTERFACE commands.  
The switch supports dynamic IP multicast routing protocols:  
DVMRP (Distance Vector Multicast Routing Protocol)  
PIM-DM (Protocol Independent Multicast – Dense Mode)  
PIM-SM (Protocol Independent Multicast – Sparse Mode).  
Management of group members is performed using IGMP (Internet Group  
Management Protocol). IGMP snooping reduces unnecessary multicast traffic  
between members of the same VLAN.  
Full multicast functionality requires IGMP and at least one of DVMRP, PIM  
Dense Mode or PIM Sparse Mode. See the IP Multicasting chapter in the Rapier  
Switch Software Reference for detailed information about multicasting.  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Layer 3  
103  
Routing Information Protocol (RIP)  
Routing protocols such as RIPv1 and RIPv2 can be enabled on a VLAN. For  
example, to enable RIPv2 on the admin VLAN, use the command:  
ADD IP RIP INTERFACE=vlan11 SEND=RIP2 RECEIVE=BOTH  
To display information about RIP (Figure 23 on page 103), use the command:  
SHOW IP RIP  
Figure 23: Example output from the SHOW IP RIP command.  
Interface Circuit/DLCI  
IP Address  
Send Receive Demand Auth Password  
-------------------------------------------------------------------------------  
vlan11  
ppp0  
-
-
-
RIP2 BOTH  
NO  
YES  
NO  
172.16.249.34 RIP1 RIP2  
PASS ********  
-------------------------------------------------------------------------------  
Novell IPX  
The switch’s implementation of the Novell IPX protocol uses the term circuit to  
refer to a logical connection over an interface, similar to an X.25 permanent  
virtual circuit (PVC) or a Frame Relay Data Link Connection (DLC). The term  
interface is used to refer to the underlying physical interface, such as VLAN,  
Ethernet, Point-to-Point (PPP) and Frame Relay.  
To create IPX circuit 1 with the Novell network number 129 over the admin  
VLAN, use the command:  
ADD IPX CIRC=1 INTERFACE=vlan11 NETWORK=129 ENCAP=802.3  
To display information about the circuits configured for IPX (Figure 24), use  
the command:  
SHOW IPX CIRCUIT  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
104  
AT-8800 Series Switch User Guide  
Figure 24: Example output from the SHOW IPX CIRCUIT command.  
IPX CIRCUIT information  
Name ......................... Circuit 1  
Status ....................... enabled  
Interface .................... vlan11 (802.3)  
Network number ............... c0e7230f  
Station number ............... 0000cd000d26  
Link state ................... up  
Cost in Novell ticks ......... 1  
Type20 packets allowed ....... no  
On demand .................... no  
Spoofing information  
Keep alive spoofing .......... no  
SPX watch dog spoofing ....... no  
On SPX connection failure .... UPLINK  
On end of SPX spoofing ....... UPLINK  
RIP broadcast information  
Change broadcasts ............ yes  
General broadcasts ........... yes  
General broadcast interval ... 60 seconds  
Maximum age .................. 180 seconds  
SAP broadcast information  
Change broadcasts ............ yes  
General broadcasts ........... yes  
General broadcast interval ... 60 seconds  
Maximum age .................. 180 seconds  
Filter information  
Filters ...................... none  
AppleTalk  
To create an AppleTalk port (interface) associated with the admin VLAN, use  
the command:  
ADD APPLE PORT INTERFACE=vlan11  
To display information about the ports configured for AppleTalk (Figure 25 on  
page 105), use the command:  
SHOW APPLE PORT  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Layer 3  
105  
Figure 25: Example output from the SHOW APPLE PORT command.  
Appletalk Port Details  
------------------------------------  
Port Number .............. 1  
Interface ................ vlan11  
ifIndex .................. 1  
Node ID .................. 217  
Network Number ........... 22  
Network Range Start ...... 22  
Network Range End ........ 22  
State .................... ACTIVE  
Seed ..................... NO  
Seed Network Start ....... 0  
Seed Network End ......... 0  
Hint ..................... YES  
Hint Node ID ............. 179  
Hint Network ............. 22  
Default Zone ............. -  
Zone List is Empty  
------------------------------------  
Resource Reservation Protocol (RSVP)  
The Resource Reservation Protocol (RSVP) enables the receiver of a traffic flow  
to make the resource reservations necessary to ensure that the receiver obtains  
the desired QoS for the traffic flow.  
RSVP is disabled by default. To enable RSVP, use the command:  
ENABLE RSVP  
Each IP interface that is to receive and process RSVP messages and accept  
reservation requests must be enabled. To enable RSVP on the admin VLAN,  
use the command:  
ENABLE RSVP INTERFACE=vlan11  
To display information about the interfaces enabled for RSVP (Figure 26), use  
the command:  
SHOW RSVP INTERFACE  
Figure 26: Example output from the SHOW RSVP INTERFACE command.  
RSVP Interfaces  
Maximum  
Interface Enabled Bandwidth(%) Bandwidth(%) Reservations Debug  
------------------------------------------------------------------------------  
Reserved  
No. Of  
Encap  
Dynamic  
vlan11  
ppp0  
No  
Yes  
Yes  
75  
75  
75  
0
0
0
0
1
0
None  
None  
None  
RAW  
RAW  
RAW  
------------------------------------------------------------------------------  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 7  
Maintenance and Troubleshooting  
This Chapter  
If you are familiar with networking and switch operations, you may be able to  
diagnose and solve some problems yourself.  
This chapter gives tips on how to:  
reconfigure your switch if you accidentally clear the FLASH memory (see  
troubleshoot a PPP link that disconnects (see What to Do if the PPP Link  
reset passwords if they are lost (see What to Do if Passwords are Lost” on  
gather information from your switch that support personnel need to  
provide accurate support tailored to your situation (see “Getting the Most  
restart the switch at any time with no configuration (see Resetting Switch  
check whether there is a connection between the switch and another  
routing interface in the network (see “Checking Connections Using PING” on  
troubleshoot if no routes exists to the remote switch (see “Troubleshooting IP  
troubleshoot problems with DHCP IP addresses if the switch is acting as a  
examine the route that packets pass between two systems running the IP  
Information gained from the LEDs on the front panel of the switch is described  
in the AT-8800 Series Switch Hardware Reference.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
108  
AT-8800 Series Switch User Guide  
How the Switch Starts Up  
The sequence of operations that the switch performs when it boots are:  
1. Perform startup self tests.  
2. Perform the install override option.  
3. Load the FLASH boot release as the INSTALL boot.  
4. Inspect and check INSTALL information.  
5. Load the required release as the main boot.  
6. Start the switch.  
7. Execute the boot script, if one has been configured.  
If a terminal is connected to asyn0, a series of status and progress messages  
similar to those shown in Figure 27 on page 108 are displayed during the  
startup process.  
Figure 27: switch startup messages.  
INFO: Self tests beginning.  
INFO: RAM test beginning.  
PASS: RAM test, 4096k bytes found.  
INFO: BBR tests beginning.  
PASS: BBR test, 128k bytes found.  
PASS: BBR test. Battery OK.  
INFO: Self tests complete  
INFO: Downloading router software.  
Force EPROM download (Y) ?  
INFO: Initial download succeeded  
INFO: Executing configuration script <boot.cfg>  
INFO: Router startup complete  
Manager >  
The startup self tests check the basic operation of the switch. If your switch  
passes these tests the switch should be able to at least proceed far enough to  
perform the load of the FLASH boot release and to start operating.  
The install override option is designed to allow a mandatory switch boot from  
the FLASH boot release. The message:  
Force EPROM download (Y)?  
is displayed on the terminal connected to asyn0 and the switch pauses. If you  
do not press a key within a few seconds, the startup process will continue and  
all steps in the sequence are executed. If the [Y], [S], [N] or [Ctrl/D] key on the  
terminal are pressed immediately after the message is displayed, you can alter  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Maintenance and Troubleshooting  
109  
Table 22: Switch startup sequence keystrokes.  
Pressing key... Forces the switch to...  
Y
S
Load the FLASH boot release, with no patch, and skip straight to step 6.  
Start with the default configuration. Any boot script or NVS  
configuration is ignored.  
N
Configure from NVS, ignoring any boot script.  
Enter diagnostics mode.  
[Ctrl/D]  
When you start the switch the FLASH boot release is always loaded first. The  
FLASH boot release contains all the code required to obtain and check the  
INSTALL information. This first boot is known as the INSTALL boot. The  
INSTALL information is inspected and the switch is setup to perform another  
load. Even if the actual release required is the FLASH boot release, another  
load is always performed. At this point, if a patch load is required, it is also  
performed.  
The switch startup occurs immediately after the install override option, or after  
the INSTALL information check. The INSTALL information check performs a  
full startup of switch software and initiates the normal operation of the switch.  
Finally, if there is a defined boot script, this script is executed.  
How to Avoid Problems  
If you perform the following procedures you may help reduce the likelihood  
and impact of some future switch events.  
Set system territory  
Set the system territory to the country or region in which the switch is  
connected to the network. Some protocols are implemented in differently in  
some countries. To ensure that the switch uses variants that will work in the  
country your switch is routing in, enter the command:  
SET SYSTEM TERRITORY={AUSTRALIA|CHINA|EUROPE|JAPAN|KOREA|  
NEWZEALAND|USA}  
Backup software files  
Store a backup of the current switch software. If the switch software is  
accidentally cleared from the router’s FLASH memory, you will need to reload  
the software release and patch files. If your access to the Internet is via the  
switch, then you will need the files on your LAN. You may wish to keep a copy  
of the current software and patch files on a TFTP server on your network. You  
can download switch software from the support site at  
Backup configuration script  
Store a backup of the latest configuration script, in case the configuration file  
on the switch is accidentally deleted or damaged.  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
110  
AT-8800 Series Switch User Guide  
Backup switch  
If your network has many switches, you may wish to keep a backup switch  
ready to replace any switch that malfunctions. When you upgrade the software  
release or patch on the other switches in the network, upgrade the backup too.  
Store on it one current config script for each switch in your network, so that  
when it is needed, you need only set the configuration file with which it boots  
to match the switch it replaces.  
Configure logging  
The logging facility stores log messages for events with a specified severity in a  
log file. You can change the size of the log file, and the kind of messages  
recorded. You can configure the switch to output log messages in several ways,  
including to a remote switch with a specified IP address, or as an email to a  
particular email address. The switch can also receive log messages from  
another switch. Set the Logging Facility to log and forward the log messages  
you need to monitor your network (see the Logging Facility chapter in the AT-  
8800 Series Switch Software Reference). Inspect the log file from time to time, and  
if difficulties arise.  
Configure Firewall  
The firewall facility is enabled with a special feature license. To obtain a special feature  
license contact an Allied Telesyn authorised distributor or reseller.  
Use the Firewall to protect your network from several kinds of unwanted  
traffic or deliberate attacks (see the Firewall chapter in the AT-8800 Series Switch  
Software Reference. A special feature licence is required.  
FLASH compaction  
If the FLASH memory gets filled beyond a certain level, it will automatically  
activate FLASH compaction to recover any space that is made available from  
deleted files. You can also activate FLASH compaction manually if required.  
While FLASH is compacting, do not restart the switch or use any commands  
that affect the FLASH file subsystem. Do not restart the switch, or create, edit,  
load, rename or delete any files until a message confirms that FLASH file  
compaction is completed. Interrupting flash compaction may result in damage  
to files. Damaged files are likely to prevent the switch from operating correctly.  
Watch for software updates  
From time to time patches may be released to improve the function of your  
switch software, and new software releases make new features available.  
Watch for patches and new software releases on the support site at  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Maintenance and Troubleshooting  
111  
What to Do if You Clear FLASH Memory  
Completely  
DO NOT clear the FLASH memory completely. The software release files are  
stored in FLASH, and clearing it would leave no software to run the switch.  
If you accidentally do this, you will need to:  
1. Boot with default configuration.  
Reboot the switch from a terminal connected the asynchronous terminal  
port (not Telnet). Use the install override to run the default configuration  
2. Log in.  
Log in to the switch using the default password friend for the manager  
account.  
3. Put current software release on server.  
Make sure you have the current software release and patch files on a server  
connected to the switch by the switch port or Ethernet port. Current  
software release and patch files are downloaded from the support site at  
4. Assign an IP address.  
Assign an IP address to the switch interface over which the software files  
5. Load software files onto switch.  
Load the required software and patch onto the switch (see Loading and  
6. Set the install information.  
Set the switch to use the software installed (see “Upgrading Switch Software”  
7. Reconfigure the switch.  
If you have a copy of the recent configuration file stored on your network,  
you can download this onto the switch too. Otherwise you will need to re-  
enter all configuration.  
While FLASH is compacting, do not restart the switch or use any commands  
that affect the FLASH file subsystem. Do not restart the switch, or create, edit,  
load, rename or delete any files until a message confirms that FLASH file  
compaction is completed. Interrupting flash compaction may result in damage  
to files. Damaged files are likely to prevent the switch from operating correctly.  
If you accidentally restart the switch, or use any commands that affect the  
FLASH file subsystem, contact your authorised distributor or reseller. You may  
have to return the switch to the factory.  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
112  
AT-8800 Series Switch User Guide  
What to Do if the PPP Link Disconnects  
Regularly  
If the device at the other end of the PPP link is not an ATR router or switch but  
is supplied by another vendor turn LQR (Link Quality Reporting) off on PPP  
links (LQR=OFF) and instead use LCP Echo Request and Echo Reply messages  
to determine link quality (ECHO=ON). Enter the command:  
SET PPP=ppp-interface ECHO=ON LQR=OFF  
What to Do if Passwords are Lost  
If a user forgets their password, to reset the password from an account with  
MANAGER privilege, enter the command:  
SET USER=login-name PASSWORD=password  
You can reset passwords for accounts with MANAGER privilege with the same  
command, provided the manager can login to at least one account with  
MANAGER privilege.  
If you require further assistance contact your authorised distributor or reseller.  
Getting the Most Out of Technical  
Support  
For online support for your switch, see our on-line support page at  
If you require further assistance, contact your authorised distributor or reseller.  
Gather as much of the following information from your switch and network as  
you can. This gives the support personnel as much information as possible to  
diagnose and solve your problem. They may ask you to send the information  
to them by email.  
Gather this information:  
Your name, organisation and contact details.  
What is the make and model of your switch? Enter the command:  
SHOW SYSTEM  
Which software release and patch files is your switch running? For  
example, 86-261.rez, 86261-01.paz. Enter the command:  
SHOW INSTALL  
What software configuration is currently running? Enter the command:  
SHOW CONF DYN  
How is the switch connected to your network? A diagram showing the  
physical configuration of the network your switch is operating in may be  
useful.  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Maintenance and Troubleshooting  
113  
To get debugging output, enter the command:  
SHOW DEBUG  
Depending on the problem, the support personnel may also ask you for the  
output from the following commands (see the Monitoring and Fault  
Diagnosis section in the Operations chapter, AT-8800 Series Switch Software  
Reference):  
SHOW EXCEPTION  
SHOW STARTUP  
SHOW LOG  
SHOW CPU  
SHOW BUFFER  
Resetting Switch Defaults  
To restart the switch at any time with no configuration, enter the command:  
RESTART SWITCH CONFIG=NONE  
If boot.cfghas changed, to set it back to the default configuration by saving  
the default dynamic configuration to the boot.cfgfile, enter the command:  
CREATE CONFIG=boot.cfg  
To set the switch to restart with the boot configuration file, enter the command:  
SET CONFIG=boot.cfg  
DO NOT clear the FLASH memory completely. The software release files are  
stored in FLASH, and clearing it would leave no software to run the switch.  
Checking Connections Using PING  
If an aspect of the router’s configuration dependent on access to a server  
functions incorrectly, PINGing the server from the switch, and the switch from  
the server, is a useful first step in diagnosis.  
You can use PING (Packet Internet Groper) to check whether there is a  
connection between the switch and another routing interface in the network.  
Use the router’s extended PING command over IPv4, IPv6, IPX and AppleTalk  
network protocols. PING sends echo request packets in the chosen format, and  
displays responses at the terminal. Enter the command:  
PING [{[IPADDRESS=]ipadd|[IPXADDRESS=]network:station|  
[APPLEADDRESS=]network.node}] [LENGTH=number]  
[NUMBER={number|CONTINUOUS}] [PATTERN=hexnum]  
[{SIPADDRESS=ipadd|SIPXADDRESS=network:station|  
SAPPLEADDRESS=network.node}] [SCREENOUTPUT={YES|NO}]  
[TIMEOUT=number] [TOS=number]  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
114  
AT-8800 Series Switch User Guide  
To set PING defaults, enter the command:  
SET PING [{[IPADDRESS=]ipadd|[IPXADDRESS=]network:station|  
[APPLEADDRESS=]network.node}] [LENGTH=number]  
[NUMBER={number|CONTINUOUS}] [PATTERN=hexnum]  
[{SIPADDRESS=ipadd|SIPXADDRESS=network:station|SAPPLEADDR  
ESS=network.node}] [SCREENOUTPUT={YES|NO}]  
[TIMEOUT=number] [TOS=number]  
To display the default PING settings and summary information, enter the  
command:  
SHOW PING  
The stop a PING that is in progress, enter the command:  
STOP PING  
If you can PING the end destination, then the physical and layer 2 links are  
functioning, and any difficulties are in the network or higher layers.  
If PING to the end destination fails, PING intermediate network addresses. If  
you can successfully PING some network addresses, and not others, you can  
deduce which link in the network is down.  
Note that if Network Address Translation (NAT) is configured on the remote switch,  
PINGing devices connected to it may give misleading information.  
For more information about using PING, see the Internet Protocol (IP) chapter in  
the AT-8800 Series Switch Software Reference.  
Troubleshooting IP Configurations  
Telnet Fails  
1. If Telnet to switch fails  
Check that the IP address you used matches the one assigned to the switch.  
To check that RIP is configured correctly, enter the command:  
SHOW IP RIP  
To check that the IP Telnet server is enabled on each switch, enter the  
command.  
SHOW IP  
If the Telnet server is disabled, enable the Telnet server with the command:  
ENABLE TELNETSERVER  
2. If Telnet to host fails  
If Telnet into a host on the remote LAN fails, but works into the remote  
switch, check that the IP address you are using is correct. To check that  
both switches are gateways, not servers, enter the command:  
SHOW IP  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Maintenance and Troubleshooting  
115  
The “IP Packet Forwarding” field in the output should be set to “Enabled”.  
Refer to the documentation for the host TCP/IP software for more  
information about configuring a gateway.  
The host’s TCP/IP software should be configured to use the Head Office  
switch as its gateway. Refer to the documentation for the host TCP/IP  
software for more information about configuring a gateway.  
3. Contact your authorised distributor or reseller for assistance  
If problems persist, contact your authorised distributor or reseller for  
assistance.  
Troubleshooting DHCP IP Addresses  
Your switch is acting as a DHCP client  
If your switch is acting as a DHCP client the switch should receive its IP  
address dynamically. If your switch is not receiving an IP address, check that  
the domain name and host name are correct.  
Your switch is acting as a DHCP server  
If your switch is not assigning IP addresses to a host, or hosts, on the subnet  
perform this procedure:  
1. Reboot the host machine, to force it to re-request IP settings.  
2. Check the host’s TCP/IP settings.  
In Microsoft® Windows™ 95/98, click Settings Control Panel →  
Network. Select TCP/IP and click Properties. Click Obtain an IP address  
automatically.  
In Microsoft® Windows™ 2000, click Settings Control Panel →  
Network and Dial-up Connections Local Area Connection →  
Properties. Select Internet connection (TCP/IP) and click Properties. Click  
Obtain an IP address automatically.  
3. Check that the DHCP server has a large enough range of addresses. To  
assign a range, enter the command:  
CREATE DHCP RANGE  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
116  
AT-8800 Series Switch User Guide  
Troubleshooting IPX Configurations  
No Routes are Visible to the Remote Router  
1. Check the PPP link  
To check that the PPP link is active, enter the command:  
SHOW PPP  
The display should look like that shown in Figure 28 on page 116. The state  
of the IPX control protocol (IPXCP) should be “OPENED”. If not, then the  
fault lies with the connection between the two switches, or the PPP  
configuration at either end of the link.  
Figure 28: Example output from the SHOW PPP command for a basic Novell IPX network.  
Name  
Enabled ifIndex Over  
CP  
State  
-----------------------------------------------------------------------------  
ppp0  
YES  
04  
IPXCP  
LCP  
OPENED  
OPENED  
isdn-roho  
-----------------------------------------------------------------------------  
To interpret output from the SHOW PPP command see the Point-to Point  
(PPP) chapter in the AT-8800 Series Switch Software Reference.  
2. Check IPX circuit configuration  
To check that the IPX circuits are correctly configured on each switch  
repeat steps 1 through 3 above, or enter the command:  
SHOW IPX CIRCUIT  
Check that there are two circuits, and for each circuit check that the circuit  
is enabled, uses the correct interface and encapsulation (for Ethernet  
interfaces), the network number is correct and “On demand” is set to “no”.  
If not, then repeat steps 1 through 3.  
3. Contact your authorised distributor or reseller for assistance  
If you still have no visible routes to the remote switch, contact your  
authorised distributor or reseller for assistance.  
Local Workstations Can Not Access Remote Servers  
A number of different events can cause this problem. The following list of  
events gives the most common:  
1. Move workstation to server LAN  
Check that when the workstation is moved to the same LAN as the file  
server, it is able to access the server. If not, the fault lies with the  
configuration of the workstation or file server. Check with your Novell  
network administrator.  
2. Check NET.CFG file  
Take care with the workstation NET.CFG file. Always specify the  
encapsulation (frame) as different LAN card drivers use different default  
encapsulations.  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Maintenance and Troubleshooting  
117  
3. Check for file server on Remote Office switch  
Does the file server appear in the IPX service table of the Remote Office  
switch? If the server does not appear in the table, its presence is not  
advertised to the local LAN. To check this, enter the command:  
SHOW IPX SERVICE  
This should produce a display like that shown in Figure 29 on page 117. The  
important point is that the file server must appear in the service table on the  
Remote Office switch and there must be a route to the file server’s internal  
network number. If there is, and it still does not work, contact your  
authorised distributor or reseller for assistance.  
Figure 29: Example output from the SHOW IPX SERVICES command for a basic Novell IPX network  
IPX services  
Name  
Address  
Age  
Server type  
Circuit  
Hops Defined  
--------------------------------------------------------------------------------  
ACCOUNTS  
00007500:000000000001:0451 0004:Fileserver  
ACCOUNTS  
00007500:000000000001:8104 0107:RCconsole  
TYPISTS  
00000012:0080488018d8:0451 0004:FileServer  
0
1 SAP  
0
1 SAP  
0
1 (vlan1)  
1 (vlan1)  
1 (ppp0)  
2 SAP  
--------------------------------------------------------------------------------  
To interpret output from the SHOW IPX SEVICES command see the Novell  
IPX chapter in the AT-8800 Series Switch Software Reference.  
4. Check route tables  
To check the route tables on both switches, enter the command:  
SHOW IPX ROUTE  
Check for the presence of networks on the remote side of the wide area  
network. If the remote network is missing from the route table on either  
switch, enter the command:  
RESET IPX  
which resets the IPX routing software and forces the switches to broadcast  
their routing and service tables.  
Using Trace Route for IP Traffic  
You can use trace route to discover the route that packets pass between two  
systems running the IP protocol. Trace route sends an initial UDP packets with  
the Time To Live (TTL) field in the IP header set starting at 1. The TTL field is  
increased by one for every subsequent packet sent until the destination is  
reached. Each hop along the path between two systems responds with a TTL  
exceeded packet and from this the path is determined.  
To initiate a trace route, enter the command:  
TRACE [[IPADDRESS=]ipadd] [MAXTTL=number] [MINTTL=number]  
[NUMBER=number] [PORT=port-number] [SCREENOUTPUT={YES|NO}]  
[SOURCE=ipadd] [TIMEOUT=number] [TOS=number]  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
118  
AT-8800 Series Switch User Guide  
Any parameters not specified use the defaults configured with a previous  
invocation of the command:  
SET TRACE [[IPADDRESS=]ipadd] [MAXTTL=number] [MINTTL=number]  
[NUMBER=number] [PORT=port-number] [SCREENOUTPUT={YES|NO}]  
[SOURCE=ipadd] [TIMEOUT=number] [TOS=number]  
As each response packet is received a message is displayed on the terminal  
device from which the command was entered and the details are recorded. To  
display the default configuration and summary information, enter the  
command:  
SHOW TRACE  
To halt a trace route that is in progress, enter the command:  
STOP TRACE  
For more information about trace route, see the Internet Protocol (IP) chapter in  
the AT-8800 Series Switch Software Reference.  
Software Release 2.6.1  
C613-02039-00 REV A  
Download from Www.Somanuals.com. All Manuals Search And Download.  

3Com Two Way Radio CP 1 User Manual
Abocom Switch UH400C User Manual
ADC Network Card CRA C User Manual
ADC Switch SWD4573I1 User Manual
Aiwa Stereo System XR EM50 User Manual
Akai Computer Monitor PDP4273M User Manual
Axis Communications Security Camera AXIS Q1931 E User Manual
Axxess Interface Automobile Accessories OESWC 8113 RF User Manual
Banner Stud Sensor MINI BEAM Expert User Manual
Behringer Stereo System FCA1616 User Manual