Aiphone Intercom System NE NVP 2DC User Manual

0710  
Vandal Proof Sub Station with Standard Call Button  
and Red Emergency Call Button  
Equipped with DPDT Contacts  
- INSTRUCTIONS -  
The NE-NVP-2DC is a vandal proof sub station designed for use with the NDR or NDRM system.  
It is constructed of 11 gauge carbon steel with a white powder-coated finish. The NE-NVP-2DC can  
be flush or surface mounted and includes tamper proof screws and a wrench for installation.  
WIRING DIAGRAM:  
NDR/NDRM  
NE-NVP-2DC  
Master  
NE-NVP-2DC  
1
2
Red  
NE-NVP-2DC  
Red  
Red  
3
~
Green  
jumper  
Green  
jumper  
Green  
jumper  
20  
(Do not cut)  
(Do not cut)  
(Do not cut)  
Wht  
Blk  
H
E
Wht  
Blk  
Wht  
Blk  
Blu  
Org  
Org  
Yel  
Yel  
Blu  
Org  
Org  
Yel  
Yel  
Blu  
Org  
Org  
Yel  
Yel  
PS-2420UL  
Contact #1  
Contact #2  
Contact #1  
Contact #2  
Contact #1  
Contact #2  
+
-
+
-
NOTES:  
1. Do not cut the green jumper on the circuit board unless an external call-placed lamp is installed at the sub station.  
2. Red Duress call button on sub station provides two sets of alternate action N/O contacts (Orange/Yellow pairs).  
Both contacts are activated by push on/push off function of Duress button. (Open when off, closed when on.)  
3. NE-NVP-2DC flush mounts into a 3-gang masonry type box (Raco #692, 697, or equivalent.)  
4. Surface mount box for NE-NVP-2DC is model SBX-NVP, sold separately.  
SPECIFICATIONS:  
Power Source:  
Speaker:  
Supplied by master station  
20 ohms, 2-½" diameter, water proof and puncture resistant, 2.4 oz. ceramic magnet  
SPST, normally open push button. Red button: Activates DPDT N/O contacts (ORG/YEL pairs).  
DPDT Relay Contacts: 6A @ 125V AC or 6A @ 30V DC. Min. 25,000 operations  
11 gauge carbon steel with powder-coated white baked epoxy finish  
Standard call button at sub latches call at NEM master until answered.  
Red emergency button is "push-on, push-off", which activates or deactivates DPDT contacts and  
red LED. "Push-on" activates relay and LED, "push-off" deactivates them.  
Hands free at sub. Master is push-to-talk or VOX with handset.  
RED: Station #  
Call Button:  
Faceplate:  
Call Annunciation:  
Communication:  
Terminal Definitions:  
BLACK: to "E" (Common)  
WHITE: to "H" (12 VDC - Powers DPDT contacts and LED)  
Wiring:  
Communication and standard call: 3 conductors homerun; or 2 common plus 1 individual per  
sub, looped through each sub. Shielded cable is recommended.  
Use Aiphone #822203 or #821803 for homerun wiring, #822206 for up to 4 stations.  
DPDT contacts require 4 additional wires from each sub station.  
420' with 22AWG; 1,000' with 18AWG (standard call and communication).  
Wiring Distance:  
Dimensions (H x W x D): NE-NVP-2DC alone: 7-1/2" x 5-1/2" x 2". With SBX-NVP: 8-5/8" x 6-5/8" x 2-1/4"  
Aiphone Communication Systems  
1700 130th Ave. N.E.  
Bellevue, WA 98005  
(425) 455-0510  
Toll Free Technical Support:  
NE-NVP-2DC Instr.  
35213 Rev. 6  
0710JD  
1-800-692-0200  
FAX (425) 455-0071  
Download from Www.Somanuals.com. All Manuals Search And Download.  

2Wire Network Router 1000S User Manual
3Com Switch 4210 18 PORT User Manual
ABC Office Paper Shredder 4107 User Manual
Aiphone Welder C User Manual
Alcatel Lucent Network Card Digital Home Care Solution User Manual
AmbiCom Network Router WL1100B AR User Manual
American Dryer Corp Clothes Dryer AD 15 thru AD 75 User Manual
Atlantis Land Switch A07 ES4649 User Manual
Axis Communications Camera Accessories Q7411 User Manual
Axis Communications Security Camera P5414 E User Manual