0710
Vandal Proof Sub Station with Standard Call Button
and Red Emergency Call Button
Equipped with DPDT Contacts
- INSTRUCTIONS -
The NE-NVP-2DC is a vandal proof sub station designed for use with the NDR or NDRM system.
It is constructed of 11 gauge carbon steel with a white powder-coated finish. The NE-NVP-2DC can
be flush or surface mounted and includes tamper proof screws and a wrench for installation.
WIRING DIAGRAM:
NDR/NDRM
NE-NVP-2DC
Master
NE-NVP-2DC
1
2
Red
NE-NVP-2DC
Red
Red
3
~
Green
jumper
Green
jumper
Green
jumper
20
(Do not cut)
(Do not cut)
(Do not cut)
Wht
Blk
H
E
Wht
Blk
Wht
Blk
Blu
Org
Org
Yel
Yel
Blu
Org
Org
Yel
Yel
Blu
Org
Org
Yel
Yel
PS-2420UL
Contact #1
Contact #2
Contact #1
Contact #2
Contact #1
Contact #2
+
-
+
-
NOTES:
1. Do not cut the green jumper on the circuit board unless an external call-placed lamp is installed at the sub station.
2. Red Duress call button on sub station provides two sets of alternate action N/O contacts (Orange/Yellow pairs).
Both contacts are activated by push on/push off function of Duress button. (Open when off, closed when on.)
3. NE-NVP-2DC flush mounts into a 3-gang masonry type box (Raco #692, 697, or equivalent.)
4. Surface mount box for NE-NVP-2DC is model SBX-NVP, sold separately.
SPECIFICATIONS:
Power Source:
Speaker:
Supplied by master station
20 ohms, 2-½" diameter, water proof and puncture resistant, 2.4 oz. ceramic magnet
SPST, normally open push button. Red button: Activates DPDT N/O contacts (ORG/YEL pairs).
DPDT Relay Contacts: 6A @ 125V AC or 6A @ 30V DC. Min. 25,000 operations
11 gauge carbon steel with powder-coated white baked epoxy finish
Standard call button at sub latches call at NEM master until answered.
Red emergency button is "push-on, push-off", which activates or deactivates DPDT contacts and
red LED. "Push-on" activates relay and LED, "push-off" deactivates them.
Hands free at sub. Master is push-to-talk or VOX with handset.
RED: Station #
Call Button:
Faceplate:
Call Annunciation:
Communication:
Terminal Definitions:
BLACK: to "E" (Common)
WHITE: to "H" (12 VDC - Powers DPDT contacts and LED)
Wiring:
Communication and standard call: 3 conductors homerun; or 2 common plus 1 individual per
sub, looped through each sub. Shielded cable is recommended.
Use Aiphone #822203 or #821803 for homerun wiring, #822206 for up to 4 stations.
DPDT contacts require 4 additional wires from each sub station.
420' with 22AWG; 1,000' with 18AWG (standard call and communication).
Wiring Distance:
Dimensions (H x W x D): NE-NVP-2DC alone: 7-1/2" x 5-1/2" x 2". With SBX-NVP: 8-5/8" x 6-5/8" x 2-1/4"
Aiphone Communication Systems
1700 130th Ave. N.E.
Bellevue, WA 98005
(425) 455-0510
Toll Free Technical Support:
NE-NVP-2DC Instr.
35213 Rev. 6
0710JD
1-800-692-0200
FAX (425) 455-0071
E-mail [email protected]