Aiphone Intercom System FK1628 B P0811JZ User Manual

FK1628 B P0811JZ  
IS SERIES  
Commercial & Security IP Video Intercom system  
Network Direct System  
INSTALLATION MANUAL  
Thank you for selecting Aiphone for your communication and security needs. Please read this manual carefully before installation,  
and keep it in a safe place for future reference.  
Also read the SETTING MANUAL and OPERATION MANUAL on the CD-ROM included with the IP master station (IS-IPMV).  
* Refer to the manuals for the standard (IP) system as needed.  
When the installation is completed, congure the system by following the SETTING MANUAL. Otherwise, the system will be non-  
functional.  
IMPORTANT  
Do not install the system until you have completely understood the system and this manual.  
The system must be installed and wired by a qualied technician well-versed in network construction.  
Please note that the illustrations in this manual may differ from the actual ones.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PRECAUTIONS  
General Prohibitions  
General Precautions  
Prohibition to Dismantle the Unit  
Prohibition on Subjecting the Unit to Water  
8. If LCD is punctured, do not allow contact with the liquid crystal  
WARNING  
inside. Inammation could result. If necessary, gargle your  
mouth and clean your eyes or skin with clear water for at least  
15 minutes, and consult your doctor.  
Negligence could result in death or serious injury.  
1. Do not dismantle or alter the unit. Fire or electric shock could  
result.  
9. Do not put anything on the unit or cover the unit with cloth, etc.  
Fire or unit trouble could result.  
2. Keep the unit away from water or any other liquid.  
Fire or electric shock could result.  
10. Do not install the unit in any of the following locations. Fire,  
electric shock, or unit trouble could result.  
3. High voltage is present internally. Do not open the case.  
Electric shock could result.  
* Places under direct sunlight or places near heating  
equipment that varies in temperature.  
4. The unit is not of explosion-proof. Do not install or use near  
gases or ammable materials. Fire or explosion could result.  
* Places subject to dust, oil, chemicals, hydrogen sulde (hot  
spring).  
5. Do not connect any non-specied power source to the +, -  
terminals. Also, do not install two power supplies in parallel to a  
single input. Fire or damage to the unit could result. Be sure to  
connect a single power supply unit to the unit.  
* Places subject to moisture and humidity extremes, such as  
bathrooms, cellars, greenhouses, etc.  
* Places where the temperature is quite low, such as inside a  
refrigerated area or in front of an air conditioner.  
6. Do not connect any terminal on the unit to an AC power line.  
Fire or electric shock could result.  
* Places subject to steam or smoke (near heating or cooking  
surfaces).  
* Where noise generating devices such as dimmer switches or  
inverter electrical appliances are closeby.  
7. Do not use power supply with a voltage other than specied.  
Fire or electric shock could result.  
* Locations subject to frequent vibration or impact.  
8. Keep AC cord from being marred or crushed. If the AC cord is  
fractured, re or electric shock could result.  
11. Do not use the handset when you perform a call test or check  
the volume, otherwise it may cause damage to your ear. Be  
sure to use the built-in speaker.  
9. Do not plug or unplug with wet hands. Electric shock could  
result.  
12. Be sure to perform a call test or check the volume with the  
handset on the hook. If you operate the hook switch with the  
handset on your ear, a sudden call etc. may arrive causing  
damage to your ear.  
10. Insert AC plug completely and securely into AC outlet.  
Otherwise, re or electric shock could result.  
11. Do not put any metal or ammable material into the unit  
through the openings. Fire, electric shock, or unit trouble could  
result.  
GENERAL PRECAUTIONS  
12. The unit must be installed and wired by a qualied technician.  
13. Existing wiring such as chime wiring, etc. may contain high  
voltage AC electricity. Damage to the unit or electric shock  
could result. Wiring and installation should be done by a  
qualied technician.  
1. Keep the unit more than 1 m (3.3') away from radio or TV.  
2. Keep the intercom wires more than 30cm (12'') away from AC  
100-240V wiring. AC induced noise and/or unit malfunction could  
result.  
3. Install the unit in an area that will be accessible for future  
inspections, repairs, and maintenance.  
CAUTION  
4. As to other manufacturer’s devices (such as door releases) used  
with this system, comply with the Specications and Warranty  
conditions that the manufacturers or venders present.  
Negligence could result in injury to people or damage to property.  
1. Do not install or make any wire terminations while power supply  
is plugged in. It can cause electrical shock or damage to the unit.  
5. If the unit is down or does not operate properly, unplug the power  
supply.  
2. When mounting the unit on a wall, install the unit in a  
convenient location, but not where it could be jarred or  
bumped. Injury could result.  
6. If it is used close to a cellular phone, the unit may malfunction.  
7. The unit can be damaged if dropped. Handle with care.  
8. The unit turns inoperative during power failure.  
3. Before turning on power, make sure wires are correctly  
connected, not crossed or not shorted. If not, re or electric  
shock could result.  
9. In areas where broadcasting station antennas are close by, the  
intercom system may be affected by radio frequency interference.  
4. Do not install the unit in locations subject to frequent vibration or  
impact. It may fall or tip over, resulting in damage to the unit or  
personal injury.  
10. All the units, except for door station, is designed for indoor use  
only. Do not use outdoor.  
11. This product, being a control unit of door release, should not be  
used as a crime prevention device.  
5. For power supply, use Aiphone power supply model or model  
specied for use with system. If non-specied product is used,  
re or malfunction could result.  
12. It must be noted in advance that the LCD panel, though  
manufactured with very high precision techniques, inevitably will  
have a very small portion of its picture elements always lit or not lit  
at all. This is not considered a unit malfunction.  
6. On products with ground terminals, connect to an earth ground.  
Fire or malfunction could result.  
7. Do not put high pressure on the monitor. If fractured, injury  
could result.  
13. Door station is weather-resistant, but do not spray with high-  
pressure water. Unit trouble could result.  
14. For wiring, specify CAT5e/6 straight cable.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
We will under no conditions be liable for damage that occurs due  
to the inability to communicate due to malfunctions, problems, or  
operational errors in this product.  
15. Due to the environmental sound around the unit, it may hinder  
smooth communication, but this is not a malfunction.  
16. When outside temperature lowers sharply after rainfall, etc., the  
inside of camera may fog up slightly, causing a blurry picture, but  
this is not a malfunction. Normal operation will be restored when  
moisture evaporates.  
We will under no conditions be liable for damage caused if a  
customer's password or transmitted information are leaked through  
bugging or unlawful computer access over Internet communication.  
We will under no conditions be liable for any damages or losses  
resulting from this product's contents or specications.  
17. Do not locate the units in a location with restricted access. It  
impedes maintenance inspection or repairs. Also, unit trouble  
could result.  
This manual was created by Aiphone Co., Ltd., all rights reserved.  
Copying a part of or this entire manual without prior permission from  
Aiphone Co., Ltd. is strictly forbidden.  
Notes on using this system  
Please note that images depicted in this manual may differ from the  
actual images.  
The ID/Password to access the web server for setting the system  
is the customer's responsibility. Make sure you set a password that  
cannot be easily guessed by a third party. We recommend that you  
change the ID/Password on a regular basis.  
Please note that this manual may be revised or changed without  
prior notice.  
Please note that product specications may be changed for the sake  
of improvement without prior notice.  
Notices  
Please be aware that it is the customer's responsibility to ensure that  
their computer is secure. We will under no conditions be liable for  
security failures.  
We will under no conditions be liable for damage that occurs due  
to failures in network equipment; failures due to internet providers  
and cell phone companies; failures such as disconnected lines and  
other losses in communication, which render it impossible to provide  
this service or in any way delay this service due to causes outside  
of our responsibility; or if an error or missing data occurs during  
transmission.  
This system is not intended for life support or crime prevention. It is  
just a supplementary means of conveying information. Aiphone will  
under no conditions be liable for loss of life or property which occurs  
while the system is being operated.  
SYSTEM CONFIGURATIONS AND CONNECTIONS  
The IS system is a commercial and security video intercom system especially designed for applications in facilities such as ofce  
buildings, factories, schools, hospitals, and prisons. Installed separately from conventional general-purpose internal communications  
systems, the IS system can be used as a video door entry system, emergency announcement system, rescue assistance system,  
urgent call system, public announcement system, and access control system.  
The IS system can be constructed on an IP network so multiple sites of IS system can be connected and controlled as a global  
system. You can design the system to any scale depending on your needs.  
Entire system  
You can construct a large-scale IS system by connecting up to 32 sites (a site can consist of up to 32 IP units) on an IP network. In  
this system, calling, communication, etc. are possible among sites.  
Site 1  
Site 32  
Site 2  
Site 4  
Site 3  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Network direct system connection diagram  
The following is an example of network direct system for controlling security and communication for facilities.  
A site must be congured with an IP-based system.  
A network direct system can consist of IP units.  
An IP unit (PC master station, IP door station or IP master station) can be connected directly to a LAN.  
In a site, up to 32 IP units can be connected.  
: Control ofce, etc.  
Site 1  
Internet / WAN  
Site 32  
Site 3  
Site 2  
Network direct system  
LAN (IP network)  
Switch (Hub)  
Switch (Hub)  
Switch (Hub)  
Switch (Hub)  
IS-IPMV  
IS-IPDV  
IS-IPDV  
/IS-IPDVF  
/IS-IPDVF  
PC master station  
(IS-SOFT)  
PS-2420/D/UL/S*1  
PS-2420/D/UL/S*1  
PS-2420/D/UL/S*1  
or  
PoE  
or  
PoE  
or  
PoE  
AC  
transformer  
AC  
transformer  
PT  
PT  
Audio  
recorder  
EL-12S  
EL-12S  
Electric door strike  
Electric door strike  
*1: Do not use PS-2420S in Europe.  
: IS system product  
Maximum number of units connectable to a site of "network direct system"  
Category  
Model name  
Type  
Max. number  
32*2  
IS-IPMV  
Color monitor IP master station  
Master station  
IS-SOFT (PC master station) PC master station  
IP  
IS-IPDV  
IP vandal-resistant video door station (surface-mount)  
IP vandal-resistant video door station (ush-mount)  
Sub station  
IS-IPDVF  
*2: Up to 31 PC master stations (IS-SOFT) can be connected within an IP network per site. If you do so, at least one color monitor IP master station  
(IS-IPMV) or IP vandal-resistant video door station (IS-IPDV or IS-IPDVF) must be also connected. (A site of network direct system cannot consist  
of PC master stations (IS-SOFT) only.)  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Cables  
Cables and connectors are not included with the products.  
Refer to page 7 to 11 for details about each unit connection.  
Notes on cables  
Odd number cables, such as  
three conductor wire, cannot be  
used.  
Unless otherwise noted, never use individual  
conductors, twisted pair cable or coaxial cable.  
Notes on CAT5e/6 cables  
Arrange the color code of the RJ45 connections in accordance  
with EIA/TIA-568A or 568B.  
Do not bend the cables to an extent where the radius is  
less than 25 mm (1”). Communication failure could result.  
Pair3  
Pair1  
Pair2  
Pair1  
CAT5e/6 cable  
Pair4  
Pair4  
Pair2  
Pair3  
1 2 3 4 5 6 7 8  
1 2 3 4 5 6 7 8  
25mm (1") or more  
T568A  
T568B  
Be sure to check the condition of cable connections with a  
LAN checker before connecting with a LAN cable.  
CAT5e/6 cable  
An RJ45 connector with a cover cannot be connected to the port  
for CAT5e/6 on IP master stations or IP door stations. Use a cable  
without a cover.  
Less than 25mm (1")  
Do not remove the CAT5e/6 cable jacket more than  
necessary.  
Do not pull or put excess strain on CAT5e/6 cables.  
Use a straight-through cable for connecting units. Use a  
crossover cable when connecting with a PC directly.  
How to connect or disconnect stranded wires.  
Twist the strands together, then insert the wire into one of the quick coupling terminals.  
To ensure that the wire won't bend, press the release button while inserting into terminal.  
e.g.) IS-IPMV (back)  
8mm  
(3/8")  
Release button  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
UNIT DETAILS  
Color monitor IP master station (IS-IPMV)  
*
For the part names and their functions, see the OPERATION MANUAL.  
Accessories  
Mounting bracket × 1  
Desktop stand × 1  
Tie-wrap × 1  
Name plate × 1  
Name card × 1  
Screw (15mm (5/8"), for wall-mounting) × 4  
Screw (25mm (1"), for gang box) × 4  
Screw (10mm (7/16"), for desktop stand) × 4  
Installation manual (a booklet in English) × 1  
CD-ROM (Installation manual, Setting manual and Operation manual) × 1  
China RoHS paper × 1  
Mounting  
When mounting on a wall  
<Back wiring>  
Mount the unit on the  
mounting bracket.  
3-gang box  
NOTE:  
3
Name card × 1 (included*2)  
A single-gang box can also be  
used for wiring. When using  
a single-gang box, fasten the  
mounting bracket to the wall  
directly by using the screw holes  
for 3-gang box.  
The unit  
CAT5e/6 cable  
Name plate × 1 (included*2)  
Mounting bracket  
(attached to the unit with shipment)  
Filling in the target names on  
the name card  
1 Remove the transparent name plate by  
pushing either upper or lower side of the  
plate.  
Fasten the mounting  
1
Screw (for gang box) × 4 (included)  
Option wires (and power wires)  
bracket to the wall.  
Remove the name card if necessary.  
*
2 Fill in the target names on the white  
space of the name card.  
3 Replace the name plate.  
2
The name plate and name card are  
attached to the unit with shipment.  
:
*
Connect the CAT5e/6 cable  
and option wires to the unit.  
2
<Surface wiring>  
Connect the CAT5e/6 cable and option wires  
to the unit and route them as shown.  
92mm (3-5/8")  
83.5mm (3-5/16")  
Mounting bracket  
(attached to the unit with shipment)  
Screw (for wall-mounting) × 4 (included)  
The unit  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7
When mounting on a desktop stand  
Set up the desktop  
stand.  
1
Mount the unit on the  
mounting bracket.  
4
* Set up the desktop stand on  
a level surface etc. so that it  
is stabilized. Fix the desktop  
stand in place if needed.  
Fasten the mounting  
bracket to the desktop  
stand.  
2
* The desktop stand allows you  
to adjust it in 3 setup angles.  
Put the leg in a groove on the  
base that corresponds to the  
desired angle.  
CAT5e/6 cable  
30r  
Leg  
Base  
The unit  
Option wires  
45r  
(and power wires)  
Screw (for desktop stand) × 4  
(included)  
Connect the CAT5e/6 cable  
and option wires to the unit.  
Desktop stand  
(included)  
Mounting bracket  
(attached to the unit  
with shipment)  
3
60r  
NOTES:  
Attach the screws to the screw holes for 3-gang box on the mounting bracket to make both  
sides of the mounting bracket contact the desktop stand.  
If necessary, secure the CAT5e/6 cable with the tie-wrap (included).  
Connections  
Audio output  
(50mVrms, 600Ω)  
Audio  
recorder, etc.  
φ
0.65-1.2 (22-16AWG)-2C  
NP  
15m (50')  
CAT5e/6  
(non-shielded)  
Switch (Hub)  
LAN/PoE  
100m (330')  
10BASE-T/100BASE-TX  
AUDIO  
OUTPUT  
A
A
φ
0.65-1.2 (22-16AWG)-2C  
NP: Non-polarized  
P: Polarized  
Power supply unit *1  
(PS-2420/D/UL/S)  
DC24V  
P
15m (50')  
*1: A power supply unit is not needed when using a switch or injector that has a PoE (Power over Ethernet) function. The unit is supplied with power  
along with data signal via a LAN cable.  
NOTES:  
Do not use the unoccupied terminals and ports for other purposes.  
In order to prevent miswiring, label both ends of each cable with the unit and terminal names to which they are to be connected.  
For connecting other manufacturer’s products, refer to the instruction manuals for those products.  
The illustration of the unit’s rear panel differs from the actual one. This is for simplifying the connection diagram.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
IP vandal-resistant video door station (IS-IPDV, IS-IPDVF)  
Accessories  
Screw (for wall-mounting) × 4 (IS-IPDV only)  
Anchor × 4 (IS-IPDV only)  
Transparent name plate × 2  
Special screwdriver × 1  
Back box × 1 (IS-IPDVF only)  
China RoHS paper × 1  
Special screw × 4 (IS-IPDVF only)  
Mounting locations  
Do not install this unit in any of the following locations where lighting or the ambient environment could impact the display on the  
video monitor due to the characteristics of the door station's camera.  
Locations subject to  
direct sunlight  
There is a white wall behind  
the caller  
Other locations subject to strong  
lighting or backlighting conditions  
a
b
c
Mounting positions and image view area of IP video door station  
Wide picture  
Objects appear  
Wide picture  
smaller due to  
Up/Down  
greater distortion  
in the surrounding  
sections compared to  
the central section,  
but a wider area is  
displayed.  
Mounting position  
1,300 mm (4' 3")  
Mounting position  
1,500 mm (5')  
Approx.  
1,050 mm  
Approx. 2,050 mm (6' 9")  
Approx. 1,050 mm (3' 5")  
Approx. 1,850 mm (6' 1")  
(3' 5")  
Unit center  
Approx. 1,050 mm (3' 5")  
Approx. 800 mm (2' 7")  
Unit center  
The display range is  
a rough estimation  
and may change due  
to the installation  
environment.  
1,500 mm (5')  
1,300 mm (4' 3")  
Approx. 1,000 mm (3' 4")  
Zoom picture  
500 mm (20")  
500 mm (20")  
Left/Right  
Approx. 700 mm (2' 3")  
An area over a range of approx. 170° in a 500 mm  
(20") radius from the camera displays.  
(The display range is a rough estimation and may  
change due to the installation environment.)  
Approx. 170°  
Approx. 900 mm (3')  
500 mm (20")  
The zoom position can be changed.  
(Refer to the OPERATION MANUAL.)  
The factory setting is "Center" for Zoom mode.  
Zoom picture (when mounting position is 1,500 mm (5'))  
Up/Down  
Zoom <Down>  
500 mm (20")  
Zoom <Up>  
Zoom <Center>  
Approx. 1,900 mm (6' 3")  
Approx. 2,300 mm (7' 7")  
Approx. 1,600 mm (5' 4")  
Unit center  
Approx. 850 mm (2' 9")  
Approx. 1,450 mm (4' 9")  
Approx. 700 mm (2' 3")  
Unit center  
1,500 mm (5')  
Approx. 850 mm (2' 9")  
Approx. 750 mm (2' 5")  
Unit center  
1,500 mm (5')  
Approx. 1,200 mm (3' 11")  
500 mm  
(20")  
500 mm (20")  
1,500 mm (5')  
Left/Right  
Zoom <Right>  
Zoom <Left>  
Zoom <Center>  
500 mm (20")  
500 mm (20")  
500 mm (20")  
Approx. 100 mm (4")  
Approx. 100 mm (4")  
Approx. 1,300 mm (4' 3")  
Approx. 900 mm (3')  
Approx. 1,300 mm (4' 3")  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Mounting  
IS-IPDV (surface-mount)  
Fasten the unit to the  
mounting surface.  
4
NOTE  
Loosen the screw  
Make room for threading a screw.  
1
*
Use board anchors or concrete  
plugs as needed.  
with the special  
screwdriver, and  
remove the front  
panel.  
Screw mounting  
Unit center  
hole x 4  
Anchor x 4  
(included)  
Ø 6 mm  
(Ø 1/4")  
35 mm  
(1-3/8")  
Vandal-resistant  
front panel  
Unit  
center  
Option wires  
(and power wires)  
Mounting height  
GL=1,500 mm (5')  
Loosen  
Special  
CAT5e/6 cable  
screwdriver  
(included)  
25 mm (1")  
25 mm (1")  
81 mm (3-1/4'')  
The unit  
Screw (for wall-mounting) × 4  
(included)  
Open the terminal cover, and  
connect the CAT5e/6 cable and  
option wires to the unit.  
3
Water escape holes  
Do not block the holes.  
Insert the transparent name plate.  
(IS-IPDV and IS-IPDVF)  
2
Tighten  
To  
insertion  
opening  
1 Peel off the protective seals on the plate (both sides).  
2 Fill in the name on the transparent name plate.  
Be sure to leave 25 mm (1") of white space on the  
right end to account for insertion.  
Attach the front panel to the unit by  
hanging the upper 2 parts on the unit.  
5
*
Tighten the screw with the lower part of  
the front panel pressed to the wall.  
3 Insert the lled-in transparent name plate at the  
specied insertion opening (indicated with  
diagram).  
in  
25 mm  
(1")  
To insertion opening  
ABCDEFG  
2 mm (1/8")  
IS-IPDVF (ush-mount)  
120 mm  
(4-3/4'')  
Flush mount back box (included)  
Vandal-resistant front panel with the unit attached  
Install the back box in the wall, and  
1
235 mm  
(9-5/16'')  
then connect the CAT5e/6 cable  
and option wires to the unit with the  
terminal cover open.  
Loosen  
Mounting height (box center)  
GL=1,500 mm (5')  
Special screwdriver  
45 mm  
(1-13/16'')  
Transparent name plate  
(included)  
Tighten  
Special screw x 4  
(included)  
Fasten the front panel to the  
back box with the special screws.  
3
Insert the transparent name plate.  
2
*
See above for details.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Connections (IS-IPDV and IS-IPDVF)  
Option  
wires  
The terminals are inside the terminal  
cover. After connecting, route the  
wires through the wiring paths, then  
close the cover.  
Inlet  
Be sure to route the CAT5e/6 cable  
and option wires through inlet.  
When closing the terminal cover,  
close it until it clicks.  
Terminal cover  
CAT5e/6 cable  
Electric door strike  
*2  
CAT5e/6  
(non-shielded)  
Switch (Hub)  
LAN/PoE  
100m (330')  
φ
0.65-1.2mm  
10BASE-T/100BASE-TX  
(22-16AWG)  
10m (33')  
AC transformer  
φ
0.65-1.2 (22-16AWG)-2C  
PT  
φ
0.65-1.2mm  
DC  
24V  
Power supply unit *1  
(PS-2420/D/UL/S)  
(22-16AWG)  
P
15m (50')  
10m (33')  
φ
0.65-1.2mm  
(22-16AWG)  
10m (33')  
P: Polarized  
Connect to the electric door strike  
according to its specications.  
*1: A power supply unit is not needed when using a switch or injector that has a PoE (Power over Ethernet) function. The unit is supplied with power  
along with data signal via a LAN cable.  
*2: Output specications  
Output method  
N/O or N/C dry closure contact  
Voltage between  
terminals  
24V AC, 0.5A (resistive load)  
24V DC, 0.5A (resistive load)  
Minimum overload (AC/DC):  
100mV, 0.1mA  
NOTES:  
Do not use the unoccupied terminals and ports for other purposes.  
In order to prevent miswiring, label both ends of each cable with the unit and terminal names to which they are to be connected.  
For connecting other manufacturer’s products, refer to the instruction manuals for those products.  
The illustration of the unit’s rear panel differs from the actual one. This is for simplifying the connection diagram.  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TECHNICAL DATA AND PRECAUTIONS  
Technical data  
Operating temperature:  
Color monitor IP master station (IS-IPMV)  
IP vandal-resistant video door station (IS-IPDV, IS-IPDVF)  
0 - 40°C (+32°F - +104°F)  
-10 - 60°C (+14°F - +140°F)  
Dimensions:  
Color monitor IP master station (IS-IPMV)  
250 (W) x 189 (H) x 59 (D) mm  
9-7/8" (W) x 7-1/2" (H) x 2-3/8" (D)  
105 (W) x 215 (H) x 32 (D) mm  
IP vandal-resistant video door station (IS-IPDV)  
4-3/16" (W) x 8-1/2" (H) x 1-5/16" (D)  
150 (W) x 265 (H) x 38 (D) mm  
5-15/16" (W) x 10-7/16" (H) x 1-1/2" (D)  
120 (W) x 235 (H) x 45 (D) mm  
IP vandal-resistant video door  
station (IS-IPDVF)  
IS-IPDVF  
Flush mount back box  
4-3/4" (W) x 9-5/16" (H) x 1-13/16" (D)  
Weight:  
Color monitor IP master station (IS-IPMV)  
Approx. 820 g (1.81 lbs.)  
Approx. 540 g (1.19 lbs.)  
Approx. 860 g (1.90 lbs.)  
Approx. 600 g (1.32 lbs.)  
IP vandal-resistant video door station (IS-IPDV)  
IS-IPDVF  
IP vandal-resistant video door  
station (IS-IPDVF)  
Flush mount back box  
Technical precautions  
Cleaning: Clean the units with a soft cloth dampened with a neutral household cleanser. Do not use an abrasive cleanser or cloth.  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WARRANTY  
Aiphone warrants its products to be free from defects of material and workmanship under normal use and service for a period of two  
years after delivery to the ultimate user and will repair free of charge or replace at no charge, should it become defective upon which  
examination shall disclose to be defective and under warranty. Aiphone reserves unto itself the sole right to make the nal decision  
whether there is a defect in materials and/or workmanship; and whether or not the product is within the warranty. This warranty  
shall not apply to any Aiphone product which has been subject to misuse, neglect, accident, power surge, or to use in violation of  
instructions furnished, nor extended to units which have been repaired or altered outside of the factory. This warranty does not cover  
batteries or damage caused by batteries used in connection with the unit. This warranty covers bench repairs only, and any repairs  
must be made at the shop or place designated in writing by Aiphone. Aiphone will not be responsible for any costs incurred involving  
on site service calls. Aiphone will not provide compensation for any loss or damage incurred by the breakdown or malfunction of its  
products during use, or for any consequent inconvenience or losses that may result.  
The object area of  
FCC  
is the EU.  
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause  
harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired  
operation.  
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.  
These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment  
generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with the instructions, may  
cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular  
installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the  
equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:  
Reorient or relocate the receiving antenna  
Connect the equipment to an outlet on a circuit different from that to which the receiver is connected. Increase the separation  
between the equipment and receiver.  
Consult the dealer or an experienced radio/TV technician for help.  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MEMO  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MEMO  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
AIPHONE CO., LTD., NAGOYA, JAPAN  
AIPHONE CORPORATION, BELLEVUE, WA, USA  
AIPHONE S.A.S., LISSES-EVRY, FRANCE  
Printed in Thailand  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Abocom Network Card WU5214 User Manual
Accell Exercise Bike CARDIO PACER User Manual
Actiontec electronic Network Router GEU404000 01 User Manual
Agri Fab Spreader 45 04631 User Manual
Aiphone Home Security System AC 10F User Manual
Aiphone Security Camera GF VAX User Manual
Aiphone Smoke Alarm 4A User Manual
AMX Network Router TPI PRO 2 User Manual
BC Speakers Speaker 15NW100 User Manual
GE Dishwasher ADW 000 SERIES User Manual