- INSTRUCTIONS -  
The JF-DVF-XP is a color audio-video door station for Aiphone’s JF-series, containing a standalone proximity card  
reader with embedded host controller. Capable of storing up to 5,000 sets of credentials (cards) and operating  
completely independent of an external host controller or PC, the JF-DVF-XP is ideal for all installations where reliable,  
inexpensive and easy-to-manage access control is desired.  
Note: Programming of the JF-DVF-XP requires Aiphone’s XP-KIT Programming Starter Kit for -XP series standalone  
proximity card readers.  
1
NAMES & FEATURES  
JF-DVF-XP  
NAMES & FUNCTIONS:  
1. Camera  
4. Speaker  
2. Microphone  
5. Call button  
1
2
3
4
5
6
3. Name placard  
6. Standalone Prox  
Reader / Controller  
FEATURES:  
· Up to 5,000 credential storage (cards)  
· Standalone configuration without central ‘Host’  
or personal computer  
· Night Lock function with contact output for  
controlling after hours access and alarm  
system mode  
· Forced Entry alarm output for triggering  
external sounder or alarm system  
· Optional handheld Remote Programmer for  
advanced functionality  
PACKAGE CONTENTS:  
OPTIONAL ACCESSORIES:  
· SBX-DVF-P Surface-mount stainless steel  
backbox  
· XC5T/9 –  
· XRP3 –  
Blank User Card (Qty. 1)  
Security Driver  
Handheld Remote Programmer  
· XP-KIT –  
Programming Starter Kit,  
contains:  
JF-DVF-XP  
Vandal-resistant Door Station  
XRP3 Qty (1)  
XC5T/9 Qty (10)  
XMMC3/9 Qty (1)  
Blank name  
placard  
(Note: XP-KIT is required for programming of  
Semi-flush backbox &  
tamper-resistant bolts  
the JF-DVF-XP!)  
Pg. 1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3
WIRING  
(See Note 4)  
(See Note 2)  
(See Note 4)  
(See Note 3)  
(See Note 1)  
Forced Entry  
Sensor Input  
Request-Exit  
(Egress) Input  
Forced Entry  
Trigger Out  
Grey  
Night Lock  
Trigger Out  
Green  
Grey / Pink  
Red / Blue  
Violet (Lock)  
Brown (Ground)  
White:  
Yellow:  
Pink:  
Not Used  
Not Used  
Not Used  
Not Used  
Red  
+
-
DC Power  
Blue:  
Strike  
Black  
12V DC  
Power Supply  
NOTES:  
1. The ‘Lock’ output (Violet wire) is a normally-open solid-state contact rated at 30VDC / 1A. Only DC-powered locks  
can be connected directly to the reader. Locks requiring AC power, higher contact rating, or Normally-Closed  
functionality should use an external 12VDC relay (Aiphone RY-18L or equivalent). Release duration is determined  
by the reader’s programming configuration (see the -XP Series Programming & Operation Manual).  
2. The ‘Request-Exit’ input is used when triggering the reader’s internal contact output from an external contact source  
is desired (motion detector, egress button, intercom relay output, etc.). An input closure should be connected  
across the Green wire and Ground (Brown wire). Unlock events triggered by this input are also subject to the  
reader’s release duration (see the -XP Series Programming & Operation Manual).  
3. When the Night Lock mode is active, a trigger will be provided across the ‘Night Lock Trigger Output’ (Red / Blue  
wire) and Ground (Brown wire). This can be used to integrate with external alarm systems for improved  
functionality.  
4. The ‘Forced Entry Sensor Input’ (Grey wire) is designed to be connected to Ground (brown wire) in series with a  
magnetic door sensor (or equivalent normally-closed device) to allow the system to determine when the door has  
been either forced, or left open after an unlock event. When this sensor input active, an output trigger will be  
provided across the ‘Forced Entry Trigger Out’ (Grey / Pink wire) and Ground (Brown wire), for connection to an  
alarm system event input, sounder, or other desired device.  
5. All device outputs (with the exception of the Violet ‘Lock’ output) provide a low current trigger output, and should not  
be used to drive anything greater than another device’s trigger input without an appropriate relay. All device inputs  
require only a contact closure across the respective wire and Ground (Brown wire).  
6. The White, Yellow, Pink, and Blue wires are not used and should be trimmed to avoid possible shorting and system  
malfunction.  
Note: Only information pertaining to the wiring of the -XP series card reader is shown in this manual. For programming  
information, consult the -XP Series Programming & Operation Manual (included in the XP-KIT Programming Starter  
Kit). For JF series intercom configuration / connection information, consult the JF series Installation and Operation  
Pg. 3  
Manual.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4
SPECIFICATIONS  
DIMENSIONS:  
5-3/4"  
4-1/8"  
3/16"  
3/16"  
JF-DVF-XP  
4-1/2"  
(BOX)  
5/8"  
5/8"  
PROGRAMMING:  
See programming instructions included with the required XP-KIT Programming Starter Kit (sold separately).  
Note: Do not attempt to program or use the JF-DVF-XP door station without first reading the  
initialization instructions included with the XP-KIT Programming Starter Kit!  
SPECIFICATIONS:  
DOOR STATION:  
Power Source:  
Camera unit:  
CARD READER:  
Power Source:  
JF-2MED master  
CCD Camera  
525 lines  
12V DC  
Current Requirements:  
Terminations:  
40mA (Avg)  
Scanning line:  
Min. illumination:  
Terminations:  
Color-coded pre-wired pigtail  
5 Lux at 1' or less  
Screw terminals  
Operating Temperature: -10°~60°C / 14°~140°F  
Operating Humidity:  
0-95% relative humidity  
non-condensing  
Operating Temperature: -10°~60°C / 14°~140°F  
Wiring Distance: 330ft w/ 87180250C wire  
FCC WARNING:  
This device complies with Part 15 of the FCC rules.  
Operation is subject to the following two conditions:  
(1) This device may not cause harmful interference.  
(2) This device must accept any interference that may cause undesired operation.  
·
·
·
For proper regulatory compliance, the drain wire should be disconnected at the  
power supply end of the cable.  
Changes or modifications not expressly approved by the party responsible for  
compliance could void the user’s authority to operate the equipment.  
The Reader is intended to be powered from a limited power source output of a  
previously certified power supply.  
Aiphone Communication Systems  
1700 130th Ave. N.E.  
Bellevue, WA 98005  
(425) 455-0510  
TOLL FREE TECHNICAL SUPPORT:  
(800) 692-0200  
Pg. 4  
JF-DVF-XP Instr.  
0609JD  
FAX (425) 455-0071  
Download from Www.Somanuals.com. All Manuals Search And Download.  

3Com Network Router WL 450 User Manual
Addonics Technologies Computer Drive AE25RDESU User Manual
AEG Dishwasher 5071 User Manual
Agilent Technologies Printer Accessories 85671A User Manual
Alliance Laundry Systems Clothes Dryer 504523R3 User Manual
Allied Telesis Network Router 86222 06 User Manual
Allied Telesis Network Router 86222 10 User Manual
Asus Network Card P5B E User Manual
Audiovox Automobile Battery Charger PRO 9056TW User Manual
Audiovox Remote Starter 07S3BP User Manual