Owner’s manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Connection
Check that your amplifier is switched off before installing your
loudspeaker. Failure to do so may result in speaker or amplifier damage.
The diagram illustrates one loudspeaker only.
Bi-amping
Bi-amping adds a second amplifier to the system. One power amplifier
drives the treble/mid section of both loudspeakers; a second drives the
bass sections. Note that the shorting links must be removed.
Failure to do so will result in damaging the amplifiers.
Conventional
Normal passive wiring requires shorting links to be in place between the
treble/mid and bass sections. The positive (ribbed) cable from the
amplifier positive (or red) terminal should connect with the positive
(red) terminal on the loudspeaker. Similarly the negative (smooth) cable
should connect the amplifier negative terminal (black) to the negative
terminal (black) on the loudspeaker.
As regards the loudspeakers, wiring for bi-amping is achieved in much
the same way as bi-wiring. Treble/mid amplifier positive (red) terminals
should be connected via the ribbed cable to the positive (red) HF
terminal on the speaker. Similarly, treble/mid amplifier negative is
connected to the negative (black) HF terminal on the speaker. Repeat
this process with the bass amplifier and LF terminal pair.
Bi-wiring
Bi-wiring separates the bass and treble ground paths in the loudspeaker
and offer sound quality advantages. An extra set of cables is required.
Note that the shorting links are removed between the treble/mid and
bass sections and should be stored for later use if conventional, passive
driving is required.
After wiring up
Lower the volume to the
minimum, switch on the
amplifier, select the signal
source and then raise the
volume to the
Two pairs of cables are connected to the amplifier terminals. One cable
of each pair should connect to the treble/mid section and one to the
bass section. The positive (ribbed) cables from the amplifier positive (or
red) terminal should connect with the positive (red) terminals on the
loudspeaker. Similarly the negative (smooth) cables in each pair should
connect the amplifier negative terminal (black) to the negative terminals
(black) on the loudspeaker.
listening level
required.
REAR OF AELITE CENTRE
RETAIN LINKS
FOR FUTURE USE
AMPLIFIER
CENTRE
Download from Www.Somanuals.com. All Manuals Search And Download.
Warranty
Specifications
HF unit
Neodymium tweeter with high
dispersion diaphragm.
Ferro fluid cooled and damped.
Magnetically shielded.
Exclusively profiled. Aluminium front
plate
Your Acoustic Energy loudspeakers are guaranteed against original defects in
materials, manufacture and workmanship for 3 years from the date of
purchase. Please retain all original packaging materials for possible future use.
We suggest that you complete details of purchase now and keep this
information in a safe place for future reference.
Under this warranty Acoustic Energy agrees to repair any defect or, at the
company’s discretion, replace the faulty component(s) without charge for parts
or labour. This warranty does not imply any acceptance by Acoustic Energy or
its agents for consequential loss or damage and specifically excludes fair wear
and tear, accident, misuse or unauthorised modification.
LF+MF units
Crossover
110mm die-cast chassis. Alloy cone
with 32mm coil. High-power,
long-throw magnet system.
Magnetically shielded.
@ 155 Hz, 2nd order LF
@ 2.9 kHz, 3rd order MF
@ 2.9 kHz, 3rd order HF
This warranty is applicable in the United Kingdom only and does not in any
way limit the customer’s legal rights. Claims and enquiries under the warranty
for AE products purchased outside the UK should be addressed to the local
importers or distributors.
Power Handling
150W max (undistorted program drive)
55Hz to 23kHz
Frequency response 6dB
Frequency response 3dB
If you have reason to claim under the warranty please contact your
dealer in the first instance.
70Hz to 20kHz
(on monitor console)
Sensitivity
90 dB/W
Dealer’s name:........................................................................................................
Address:....................................................................................................
.................................................................................................................
.................................................................................................................
Date of purchase:....................................................................................................
Serial numbers:.......................................................................................................
Impedance
Cabinet
8 ohm (4 ohm minimum)
Real wood veneered. 15 mm MDF wall.
Dual chamber, high power, low
turbulence bass reflex port. 22 mm
MDF front baffle.
Acoustic Energy Limited
16 Bridge Road, Cirencester
Gloucestershire GL7 1NJ
Tel +44(0)1285 654432
Terminals
Gold-plated 4-way binding posts.
8.0kg
Weight (excl. packaging)
Dimensions (WxHxD)
450 x 190 x 297 mm
Fax +44(0)1285 654430
Download from Www.Somanuals.com. All Manuals Search And Download.
|