Acer AN1600 F1 Network Storage System Specifications  
AN1600 F1 Product Overview  
The Acer AN1600 F1 storage system is a cost-effective storage solution, powered by Microsoft Windows  
Storage Server offering an easy way for storage centralization, file sharing, data protection, and remote  
access.  
Product Front view  
Product inside view  
1. 12 x ECC DDR3 1066/1333 MHz registered or unbuffered memory slots  
2. 2 x Intel® Xeon® 5600 series processors supporting up to 6-cores per processor  
3. 2 x 720 W 80 PLUS® gold-level efficient hot-swap power supplies (1+1 redundant)  
4. Hot-plug redundant system cooling fans  
5. Power button, System ID button, LED indicators (Power, HDD activity, LAN 1-2 status, system  
ID/status/fault)  
6. Support for up to twelve 3.5” hot-plug SATA or SAS hard disk drives  
7. 7 x PCI Express® slots with risers  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
Acer AN1600 F1 Network Storage System Specifications  
Features and Benefits  
Unified Storage File Server  
Centralized information management with Microsoft based storage  
operating system to manage, protect, and expand.  
Efficient Operation  
Works together with Acer Smart Setup and Acer Smart Manager for  
ease of installation and setup. Microsoft Management Console user  
interface from Windows storage operating system enables features  
such as iSCSI and SIS1 to reduce maintenance and speed backup.  
Expansion as needed; built upon  
storage industry standards  
Leveraging industry standard SAS/SATA to allow cost effective  
expansion to external storage through fibre channel. Powered by the  
latest Intel processors to protect your investment and resources for  
years to come.  
Designed for budget conscious  
companies looking for enterprise  
class features  
Based on an established Server design using server processors,  
industry standard HDDs, interconnects, DDR3 memory, and hot-plug  
redundant power supplies; the AN1600 F1 is equipped with enterprise  
level features such as file de-duplication, snapshots, and distributed file  
system replication.  
Standard Features  
Acer Smart Server Manager  
Offers 24-7 monitoring for system health and performance.  
Delivering proactive event management features including system event logging, event handling from e-  
mail and SNMP Trap (PET) alerting.  
Allowing remote control from KVM and Power control.  
Satisfying management in web-based UI, role-based administration, and automated management scripts.  
Acer Smart Console  
Web-based management utility to simplify system management with embedded iBMC  
System monitoring and alerting, event handling, remote power control and KVM-over-IP.  
Acer Smart Console is OS independent, and offers virtual media through floppy, ODD, and removable  
disk.  
Out-of-band (OOB) management regardless OS status.  
Acer Recovery Utility  
A friendly and an intuitive system recovery utility to return to its original factory state.  
Supports over twenty some different languages.  
Wizard step by step guiding through the complete recovery processes.  
Acer Resource Kit  
Comprehensive system information in one single disk including System drivers, LAN, RAID, and iSCSI  
Target Client utilities, and User Guide.  
GN1600 F1 features Windows Storage Server R2 Operating System  
Microsoft® Windows® Storage Server 2008 R2 operating system provides file storage and print server  
capabilities for client and server computers in your network environment. Storage appliances running Windows  
Storage Server 2008 R2 can be used in failover clusters, providing high availability storage for application  
servers and file storage.  
1 SIS: Single Instance Storage can recover up to 35% of disk capacity by reducing the number of redundant files.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Acer AN1600 F1 Network Storage System Specifications  
Single Instance Storage (SIS) v2  
File Server Optimization  
SIS reduces the amount of storage used by data by replacing  
multiple identical copies with logical links to a single source copy.  
Windows Storage Server 2008 R2 is tuned to provide better  
performance in a file server role, realizing as much as an 8%  
performance gain in file system operations.  
Remote Administration in  
Heterogeneous Environments  
Remote administration of Windows Storage Server 2008 R2  
appliances can be done from Internet Explorer using an ActiveX  
control, and from non-Microsoft browsers using a Java control.  
Windows Storage Server 2008 R2 offers performance  
enhancements for the Print Services role.  
Print Services  
Distributed File System (DFS)  
Namespace and Replication  
Windows Storage Server 2008 R2 can provide DFS support for file  
sharing for WANs and satellite offices  
Microsoft iSCSI Software Target  
Microsoft iSCSI Software Target provides centralized, software-based and hardware-independent iSCSI disk  
subsystems in storage area networks (SANs). You can use iSCSI Software Target, which includes a Microsoft  
Management Console (MMC) snap-in, to create iSCSI targets and iSCSI virtual disks. You can then use the  
Microsoft iSCSI Software Target console to manage all iSCSI targets and virtual disks created using iSCSI  
Software Target.  
Microsoft iSCSI Software Target 3.2 provides the following features:  
Server Manager  
Integration  
Manage your Microsoft iSCSI Software Target from Server  
Manager.  
Improved CHAP Secret  
Storage  
Microsoft iSCSI Software Target 3.2 uses a more secure and  
customizable storage method for CHAP secrets.  
ERL0 Compliant  
Connection and session reinstatement is now fully ERL0  
compliant.  
Microsoft Management Console  
Microsoft® Management Console (MMC) is an extensible common presentation service for management  
applications. MMC unifies and simplifies day-to-day system management tasks. It hosts tools and displays  
them as consoles. These tools, consisting of one or more applications, are built with modules called snap-ins.  
The snap-ins also can include additional extension snap-ins. Microsoft Management Console enables system  
administrators to create special tools to delegate specific administrative tasks to users or groups. Microsoft  
provides standard tools with the operating system that perform everyday administrative tasks that users need  
to accomplish.  
Task Orientation  
The tools being defined to work with MMC are task oriented in  
naturethey cater to the task being performed rather than merely  
displaying the raw objects that can be manipulated. Also, because  
administrators can customize their own tools, using pieces from  
various vendors, they can create tools that contain only the UI they  
need to complete their tasks.  
Integration  
The UI for all the management tasks an administrator must  
perform are collected into a single console. As new applications  
are added to a computer or network, their administration is  
integrated into the existing administration common console.  
Customization of Consoles  
Administrators can create custom consoles tailored to their  
particular management needs. This is useful in enterprise  
environments that divide administrator groups according to duties.  
For example, you can create a custom console for software  
installation and maintenance, another one for scripts  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Acer AN1600 F1 Network Storage System Specifications  
administrators, another one for security Group Policy, and so on.  
Delegation  
Administrators can easily modify existing tools to create new tools  
with reduced functionality and less complex views of the tool  
namespace, and then give these tools to others. A person who  
receives such a tool is presented with a simpler, more manageable  
view of the tasks they are being asked to perform.  
Overall Interface  
Simplification  
All tools built for MMC, from Microsoft or third-party software  
vendors, will have a similar appearance, making it easier for users  
to use all tools after learning one. Because you can mix and match  
tools from any vendor, you can use the best tool from each  
management product category. MMC also enables a single piece  
of software to provide functionality across the interface in a  
consistent manner.  
Extensibility  
Developers can extend the base functionality of MMC snap-ins by  
creating extension snap-ins. This allows software vendors to reuse  
Microsoft tools without writing a lot of code. Various mechanisms  
are available for extending snap-ins, including extending the  
namespace, context menus, toolbars, Property pages, and  
creating Wizard 97-style pages.  
Product Specifications  
Processors and chipset  
2 x Intel® Xeon® E5620 processors (2.4 GHz, 12 MB L3 cache, 5.86 GT/s, DDR3-1066, 80 W, HT)  
Intel® 5520 Chipset  
Memory  
Memory capacity:  
Registered DIMM: 2, 4, 8 GB  
Up to 32 GB supported by the OS.  
Minimum: 6GB Required  
Network Controllers  
Integrated Intel® 82576EB dual-port Gigabit Ethernet controllers (2 ports total)  
Storage  
Hard disk form factor: 3.5”  
Type: SAS/ SATA with hot plug capability  
HDD Capacity (enterprise level):  
3.5” SAS HDD capacity: 300 GB, 450 GB, 600 GB  
3.5” SATA HDD capacity: 250 GB, 500 GB, 1TB, 2TB  
3.5” Maximum capacity:  
Up to 24 TB SATA HDD (2 TB 3.5" x 12 HDDs)  
Up to 7.2 TB SAS (600 GB 3.5” x 12 HDDs)  
Storage controllers  
LSI SAS MegaRAID SAS PCIe 2.0 x16 9260-16i with 16-internal ports, 512 MB, supporting RAID  
0/1/10/5/50/6/60 (default bundle in system)  
Expansion slots  
Two full height PCI-E 2.0 x8 slots (with x4 link; left)  
One full height PCI-E 2.0 x16 slot (with x8 link; left)  
Two low profile PCI-E 2.0 x8 slots (with x4 link; right)  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Acer AN1600 F1 Network Storage System Specifications  
One low profile PCI-E 2.0 x8 slot (right)  
One Acer Flex I/O (PCI-E 2.0 x8) slot (left)  
Operating System  
Microsoft® Windows® Storage Server 2008 R2, Standard x64 edition  
Management  
Acer Smart Console  
Acer Smart Server Manager  
iBMC management controller, supporting base board management and KVM-over-IP  
LSI MSM (MegaRAID Storage Manager) on-line utility is the OS level utility for data volume RAID  
configuration  
LSI WebConsole utility is a ROM-based utility provided by HBA FW for data volume RAID  
configuration  
Windows Disk Management is OS built-in feature on Windows Storage Server 2008 R2  
Microsoft Windows Storage Server Administration Tools  
Deployment/serviceability  
BIOS Update Tool  
IPMI Firmware Update Tool  
Input/output interface  
Front  
One Power/off button  
LED indicators: power, HDD activity, LAN port 1 through 2, and ID  
Rear  
PS2 keyboard port  
PS2 mouse port  
Two USB 2.0 ports  
Two RJ-45 ports (dual Gigabit NIC) with activity and link indicators  
RJ-45 port (dedicated for management NIC) with activity and link indicators  
Serial (DB-9) port  
SVGA (DB-15) port  
ID LED  
Chassis / Form factor  
2U rack optimized for up to 12 hot-plug SAS/SATA 3.5” HDDs  
Power supply  
2 x 720 W 80 PLUS® Gold-level efficient hot-swap power supplies standard (1+1 redundant)  
Regulatory compliant standards  
EMC  
FCC (Class A)  
CE (Class A)  
BSMI (Class A)  
Safety  
UL/cUL  
CB  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Acer AN1600 F1 Network Storage System Specifications  
Technical Specifications  
Dimensions  
(with bezel)  
438.4 mm (W) x 705 mm (D) x 88.1 mm (H) ( 17.3 x 27.8 x 3.5 inches)  
Form factor  
2U rack mount (with cable arms included)  
Weight  
Maximum  
38 kg (84 lbs.)  
(approximate)  
(All component slots and sockets  
fully populated)  
Minimum  
27.5 kg (60.6 lbs.)  
(One HDD, power supply, and  
processor installed)  
BTU rating  
Maximum  
Operating  
2456.64 BTU/hr.  
System inlet  
temperature  
0° - 35°C (50° - 95°F) at sea level with an altitude  
derating of 1°C per 305 m (1.8°F per 1000 ft.)  
above sea level to a maximum of 3050 m (10,000  
ft.) with no direct sustained sunlight. Maximum rate  
of change is 10°C/hr. (18°F/hr.). The upper limit  
depends on the type and number of options  
installed. System performance may be reduced if  
operating with a fan fault or above 30°C (86°F).  
-40° - 70°C (-40° - 158°F) maximum rate of change  
is 20°C/hr. (36°F/hr.).  
Non-operating  
Relative humidity Operating  
(non-  
8 - 90 % relative humidity (Rh), 28°C (82.4°F)  
maximum wet bulb temperature, non-condensing  
5 - 95 % relative humidity (Rh), 38.7°C (101.7°F)  
maximum wet bulb temperature, non-condensing  
condensing)  
Non-operating  
Emissions  
classification  
(EMC)  
FCC rating  
Class A  
Normative standards  
EN55022, EN 61000-3-2, EN 61000-3-3, CISPR  
22 Class A  
Power supply  
Rated steady-state power  
Maximum peak power  
720 W (at 100 VAC)  
720 W (at 200 VAC)  
720 W (at 100 VAC)  
720 W (at 200 VAC)  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Acer AN1600 F1 Network Storage System Specifications  
Expansion slots  
The primary I/O bus for the main board is PCIe Gen2. The following table lists the characteristics  
of the PCI-E bus segments.  
PCI express Bus Segment Characteristics of PCI Express Topology  
Expansion Slot # # of  
slots  
Type  
Bus  
Vol.  
Con.  
Width  
Location Length  
Width1  
PCIe  
PCIe  
PCIe  
PCIe  
2
1
2
1
1
PCIe Gen 2  
PCIe Gen 2  
PCIe Gen 2  
PCIe Gen 2  
PCIe Gen 2  
x4  
x8  
x4  
x8  
x8  
3.3V  
3.3V  
3.3V  
3.3V  
3.3V  
x8  
Left  
Full height  
x16  
x8  
Left  
Full height  
Low profile  
Low profile  
Right  
Right  
Left  
x8  
Acer Flex I/O  
x8  
NOTE:  
1. "Bus Width" refers to the number of physical electrical lanes running to a PCIe® connector.  
2. Default bus assignment (in decimal). Inserting cards with PCI™ bridges may alter the actual bus assignment  
number.  
3. Slots are enumerated differently based on the operating system. Microsoft® operating systems enumerate Device  
ID by bus starting from the lowest bus to the highest.  
Embedded dual-port Network interface  
10Base-T  
Gigabit server  
adapter (Intel  
82576EB) two port  
total  
100Base-TX  
1000Base-TX  
Compatibility  
IEEE 802.3 10Base-T  
IEEE 802.3ab 1000Base-T  
IEEE 802.3u 100Base-TX  
Data transfer method Four lane (x4), 100 MHz PCI Express reference clock  
Network transfer rate 10Base-T (half-duplex)  
10Base-T (full-duplex)  
10 Mb/s  
20 Mb/s  
100 Mb/s  
200 Mb/s  
100Base-TX (half-duplex)  
100Base-TX (full-duplex)  
1000Base-TX (half- and full-duplex) 2000 Mb/s  
Connector  
RJ-45  
Cable support  
CAT 5e wire  
Virtualization  
acceleration  
Intel I/O Acceleration Technology  
Virtual Machine Device Queues (VMDq)  
PCI-SIG SR-IOV implementation  
Manageability  
NC-SI SMBus, PXE, iSCSI boot  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
Acer AN1600 F1 Network Storage System Specifications  
Storage  
Maximum internal Hard disk drive  
storage  
Up to 12 hot-pluggable 3.5" SATA/SAS HDD  
3.5” Maximum  
capacity  
Up to 24 TB SATA  
Up to 7.2 TB SAS  
Drive Support Optical and Hard Disk Drive  
Optical Drive Support  
Drive  
Bay Supported  
External Only  
Required Controller  
USB 2.0  
Optical Drive  
Hard Disk Drive Support  
Drive  
Quantity  
Supported  
Bay Supported  
0 - 11  
Required Controller  
16-port SAS RAID card for  
up to 12 SAS/SATA HDD’s  
3.5” SATA/SAS hard drive  
*standard on some models  
Up to 12  
NOTE: Transfer rates of drives are dependent on the maximum transfer rate supported by the  
host bus adapter (HBA) or controller.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Acer AN1600 F1 Network Storage System Specifications  
RAID Volume and Setup Layout  
Default 2 HDDs RAID Volume and system partition  
Default 8 HDDs RAID Volume and system partition  
Default 12 HDDs RAID Volume and system partition  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Acer AN1600 F1 Network Storage System Specifications  
Memory Support Specification  
Registered Type  
DDR3 1066/ 1333 MHz  
Capacity: 2, 4, 8 GB  
Voltage: 1.5 V  
Maximum: 192 GB (16 GBx12 DIMMs)  
ECC, Mirroring, Sparing, Lockstep Mode, x4/x8 SDDC  
Memory protection  
Note: Mixing of registered memory and unbuffered ECC memory is not supported  
16 GB memory modules available by special request only  
Memory Population  
The systems have twelve DIMM slots. Each CPU controls six slots. The DIMM slots support DDR3-1333  
registered ECC memory modules.  
Each CPU has three memory channels (channel 1, 2 and 3)  
Each channel has 2 slots  
The socket furthest from the CPU is socket A (P1DIMM1A, P1DIMM2A, P1DIMM3A in blue color), while  
the nearest is socket B (P1DIMM1B, P1DIMM2B, P1DIMM3B in black). For all memory modes, socket A  
in each channel needs to be populated first. If socket A is empty, socket B cannot be used. It is  
recommended that the higher rank and largest capacity DIMM be installed in slot A.  
For the system to function properly, DIMM modules must be installed following the slot sequence listed  
below. DIMM modules of the same type, size and manufacturer must be installed in the same DIMM  
colored slots.  
CPU 1 populate DIMM slot P1DIMM1A first, followed by slots P1DIMM2A, P1DIMM3A, P1DIMM1B,  
P1DIMM2B, P1DIMM3B.  
CPU 2 populate DIMM slot P2DIMM1A first, followed by slots P2DIMM2A, P2DIMM3A, P2DIMM1B,  
P2DIMM2B, P2DIMM3B.  
DIMM slot notation illustrated in table below:  
CPU1  
P1DIMM1B  
P1DIMM1A  
P1DIMM2B  
P1DIMM2A  
P1DIMM3B  
P1DIMM3A  
(Rear CPU)  
Black  
Blue  
Black  
Blue  
Black  
Blue  
CPU2  
P2DIMM1B  
P2DIMM1A  
P2DIMM2B  
P2DIMM2A  
P2DIMM3B  
P2DIMM3A  
(Front CPU)  
Black  
Blue  
Black  
Blue  
Black  
Blue  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Acer AN1600 F1 Network Storage System Specifications  
Independent mode (please refer to the User Guide for more information)  
In this mode all memory is accessible and ECC protected  
Single-processor configuration  
Total  
P1  
P1  
P1  
P1  
2A  
P1  
3B  
P1  
3A  
Memory  
1B  
1A  
2B  
2GB  
2GB  
4GB  
2GB  
2GB  
2GB  
2GB  
4GB  
4GB  
4GB  
4GB  
4GB  
8GB  
8GB  
8GB  
8GB  
2GB  
6GB  
2GB  
2GB  
2GB  
2GB  
8GB  
2GB  
2GB  
12GB  
4GB  
2GB  
2GB  
2GB  
2GB  
8GB  
4GB  
4GB  
4GB  
4GB  
12GB  
16GB  
24GB  
8GB  
4GB  
4GB  
4GB  
4GB  
4GB  
4GB  
4GB  
16GB  
24GB  
32GB  
8GB  
8GB  
8GB  
8GB  
8GB  
8GB  
Dual-processor configuration  
CPU1  
CPU2  
Total  
Memory  
4GB  
P1  
1B  
P1  
P1  
2B  
P1  
2A  
P1  
3B  
P1  
3A  
P2  
1B  
P2  
P2  
2B  
P2  
2A  
P2  
3B  
P2  
3A  
1A  
1A  
2GB  
2GB  
2GB  
2GB  
2GB  
2GB  
4GB  
4GB  
4GB  
4GB  
2GB  
2GB  
2GB  
2GB  
2GB  
2GB  
4GB  
4GB  
4GB  
4GB  
8GB  
2GB  
2GB  
2GB  
2GB  
2GB  
2GB  
2GB  
2GB  
2GB  
2GB  
12GB  
16GB  
18GB  
24GB  
8GB  
2GB  
2GB  
2GB  
2GB  
2GB  
2GB  
2GB  
2GB  
2GB  
2GB  
2GB  
2GB  
2GB  
2GB  
2GB  
2GB  
2GB  
2GB  
2GB  
16GB  
24GB  
32GB  
4GB  
4GB  
4GB  
4GB  
4GB  
4GB  
4GB  
4GB  
4GB  
4GB  
4GB  
4GB  
Mirroring mode:  
In mirroring mode, the memory contains a primary image and a copy of the primary image therefore the  
effective size of memory is reduced by one half.  
Channel 3 has no function in these modes.  
Follow the population rules described in independent mode.  
Mirroring mode needs the channel 1 & channel 2 DIMMs to be identical. DIMM slot populations within a  
channel do not have to be identical but the same DIMM slot location across channel 1 and channel 2  
must be the same. DIMM1A and DIMM2A should be the same type, size and manufacturer. DIMM1B  
and DIMM2B memory should be the same type, size and manufacturer. DIMM1C and DIMM2C  
memory should be the same type, size and manufacturer.  
Same rules apply to CPU2.  
Please refer to the User Guide for complete population rules for both single and dual processor  
configurations.  
Lockstep mode:  
In Lockstep Channel Mode, each memory access is 128-bit data access that spans Channel 1 and  
Channel 2. This is done to support SDDC for DRAM devices with 8-bit wide data ports. The same  
address is used on both channels such that an address error on any channel is detectable.  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Acer AN1600 F1 Network Storage System Specifications  
Lockstep Channel mode is the only RAS mode that supports x8 SDDC.  
Channel 3 has no function in these modes.  
Follow the population rules described in independent mode.  
Lockstep mode needs the channel 1 & channel 2 DIMMs to be identical. DIMM slot populations within a  
channel do not have to be identical but the same DIMM slot location across channel 1 and channel 2  
must be the same. DIMM1A and DIMM2A should be the same type, size and manufacturer. DIMM1B  
and DIMM2B memory should be the same type, size and manufacturer. DIMM1C and DIMM2C  
memory should be the same type, size and manufacturer.  
Same rules apply to CPU2.  
Please refer to the User Guide for complete population rules for both single and dual processor  
configurations.  
Sparing mode:  
In sparing mode, if the system detects degrading memory, the data in the failed channel will be copied to  
the spare channel. The failed channel is then isolated and the spare channel becomes active. Any  
uncorrectable error detected before the isolation will cause the system to stop normal operation.  
Channel 3 is the spare channel. Therefore, the effective size will be reduced by one-third.  
Follow the population rules described in independent mode.  
Sparing mode needs all three channels to utilize identical DIMMs. 1A, 2A and 3A should be the same  
type, size and manufacturer. 1B, 2B and 3B memory should be the same type, size and manufacturer.  
1C, 2C and 3C memory should be the same type, size and manufacturer.  
Same rule is applied to CPU2.  
Please refer to the User Guide for complete population rules for both single and dual processor  
configurations.  
Memory Identification  
Generally, there is memory information printed on the label of the DIMM, but different vendors may have  
different formats. For example:  
4GB 2Rx4 PC3-10600R xx xx xxx  
1. Density  
2GB, 4GB, 8GB, 16GB  
Intel® Xeon® 5600 series processors support DIMMs organized by 1Gb, 2Gb or 4Gb DRAM chips  
2. Rank  
1R = Single Rank  
2R = Dual Rank  
4R = Quad Rank  
3. Bit Organization  
This platform supports x4 and x8  
Note: It’s not recommend to mix DIMMs with different bit organizations in one system  
4. Speed  
PC3 6400 => DDR3- 800  
PC3 8500 => DDR3- 1066  
PC3 10600 => DDR3- 1333  
PC3 12800 => DDR3- 1600  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Acer AN1600 F1 Network Storage System Specifications  
Power Supply Specification  
720W Power Supply  
Operational Input Voltage  
Range (Vrms)  
100 to 240 VAC  
50 / 60  
Frequency Range  
(Nominal) (Hz)  
Nominal Input Voltage  
(Vrms)  
100  
120  
208  
200  
220  
230  
240  
Max. Rated Output Wattage  
720  
720  
720  
720  
720  
720  
3.5  
720  
Nominal Input Current (A  
rms)  
8.46  
6.97  
3.80  
3.87  
3.74  
3.29  
Max. Rated Input Wattage  
Rating (Watts)  
846.0  
836.4  
790.4  
774.0  
822.8  
805.0  
789.6  
Max. Rated VA (Volt-Amp)  
837.54  
88.12  
828.03  
89.49  
774.59 758.52 806.34  
788.9  
91.92  
773.81  
92.27  
Efficiency (%) at Max.  
Rated Output Wattage  
90.95  
90.74  
91.51  
Power Factor  
0.99  
0.17  
0.99  
0.19  
0.98  
0.29  
0.98  
0.31  
0.98  
0.35  
0.98  
0.37  
0.98  
0.41  
Leakage Current (mA)  
Max. Inrush Current (A  
peak)  
17.24  
19.41  
18.52  
16.88  
16.48  
20.47  
22.54  
Max. Inrush Current  
Duration (mS)  
4.62  
4.58  
4.61  
4.62  
4.64  
4.63  
4.64  
Max. British Thermal Unit  
Rating (BTU/hr.)  
2456.64  
2456.64 2456.64 2456.64 2456.64 2456.64  
2456.64  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Acer AN1600 F1 Network Storage System Specifications  
Hardware Key Options  
HDD  
SAS 3.5”: 300 GB, 450 GB, 600 GB  
SATA 3.5”: 250 GB, 500 GB, 1TB, 2 TB  
Memory  
DDR3 1333 MHz Registered ECC 2/ 4/ 8 GB  
SAS RAID  
MegaRAID SAS 9240-4i, 4 internal ports, PCIe x8, supporting RAID 0/1/10/5  
MegaRAID SAS 9260-16i, 16 internal ports, 512 MB PCIe x8, supporting  
RAID 0/1/10/5/50/6/60  
LSI® BBU07/ Battery Backup Unit for MegaRAID SAS 9260-8i and 9260-16i  
Qlogic SANblade® QLE2460 single port fibre channel to PCI express host  
bus adapter, 1 ch, 8 Gb FC HBA, PCIe x8, single LC port (std & low-profile  
bracket)  
Fibre Channel HBA  
Rackmount kits  
Qlogic SANblade® QLE2462 dual ports fibre channel to PCI express host  
bus adapter, 2ch, 8 Gb FC HBA, PCIe x8, dual LC port (std & low-profile  
bracket)  
Sliding rails (Cable Management Arm option available)  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Acer AN1600 F1 Network Storage System Specifications  
Service and Support  
Acer Servers offer a comprehensive service suite to take care of daily IT needs. Users can select the 3-  
year standard warranty or choose extended warranties and services2.  
The standard warranty for the AN1600 F1 includes 3 years Parts coverage with the first year including  
Labor and On-Site coverage.  
Warranty repairs may be accomplished through the use of Customer Replacement Unit (CRU) parts. CRU  
parts include: Hot Plug Hard Drives and Hot Plug Power Supplies. These parts are designed for easy  
replacement without tools. Travel and labor charges may apply if customers decline to replace a CRU part.  
In a continuing effort to improve the quality of our products, information in this document is subject to change without  
notice. Images shown are only representations of some of the configurations available for this model. Availability may  
vary depending on region. Microsoft and Windows are registered trademarks of Microsoft Corporation. Intel, the Intel  
logo, Pentium, Xeon and Xeon Inside are trademarks of Intel Corporation.  
© 2010. All rights reserved.  
2
Extension warranty services may vary by country. Please contact your Acer authorized reseller for more information.  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Acer AN1600 F1 Network Storage System Specifications  
Acer Standard Storage Models  
Part Number  
Acer AN1600 Models  
Acer AN1600F1 Xeon E5620, 2x4GB DDR3 Reg, 2 x 300GB SAS, 4 Port 6G SAS RAID controller,  
2x720W 80+ Gold PSU, 2x GBit LAN onboard, Acer Smart Manager, UPS Power Cable, no Mouse, no  
KB, Rail kit (2U) Included  
TS.R760R.015  
TS.R760R.011  
TS.R760R.012  
TS.R760R.013  
TS.R760R.014  
Acer AN1600F1 Xeon E5620, 2x4GB DDR3 Reg, 12 x 300GB SAS, 16 Port 6G SAS RAID controller,  
2x720W 80+ Gold PSU, 2x GBit LAN onboard, Acer Smart Manager, UPS Power Cable, no Mouse, no  
KB, Rail kit (2U) Included  
Acer AN1600F1 Xeon E5620, 2x4GB DDR3 Reg, 12 x 1TB SATA, 16 Port 6G SAS RAID controller,  
2x720W 80+ Gold PSU, 2x GBit LAN onboard, Acer Smart Manager, UPS Power Cable, no Mouse, no  
KB, Rail kit (2U) Included  
Acer AN1600F1 Xeon E5620, 3x4GB DDR3 Reg, 12 x 600GB SAS, 16 Port 6G SAS RAID controller,  
2x720W 80+ Gold PSU, 2x GBit LAN onboard, Acer Smart Manager, UPS Power Cable, no Mouse, no  
KB, Rail kit (2U) Included  
Acer AN1600F1 Xeon E5620, 3x4GB DDR3 Reg, 12 x 2TB SAS, 16 Port 6G SAS RAID controller,  
2x720W 80+ Gold PSU, 2x GBit LAN onboard, Acer Smart Manager, UPS Power Cable, no Mouse, no  
KB, Rail kit (2U) Included  
Acer Memory  
Note: please refer to "Memory Support" Section for details on configuring memory  
Acer Registered Memory  
Acer 2GB DDR3-1333Registered Memory Kit (1 pc.)  
Acer 4GB DDR3-1333Registered Memory Kit (1 pc.)  
Acer 8GB DDR3-1333Registered Memory Kit (1 pc.)  
Acer Storage  
TC.33100.029  
TC.33100.031  
TC.33100.042  
Acer SATA Hot Plug LFF (3.5-inch) Midline (MDL) Drives  
Acer 250GB 3Gb/s 7.2K 3.5-inch Enterprise SATA HDD Kit  
Acer 500GB 3Gb/s 7.2K 3.5-inch Enterprise SATA HDD Kit  
Acer 1TB 3Gb/s 7.2K 3.5-inch Enterprise SATA HDD Kit  
Acer 2TB 3Gb/s 7.2K 3.5-inch Enterprise SATA HDD Kit  
Acer SAS Hot Plug LFF (3.5-inch) Enterprise Drives  
Acer 300GB 6Gb/s 15K 3.5-inch Enterprise SAS HDD Kit  
Acer 450GB 6Gb/s 15K 3.5-inch Enterprise SAS HDD Kit  
Acer 600GB 6Gb/s 15K 3.5-inch Enterprise SAS HDD Kit  
Acer SAS Storage Controllers  
TC.32700.068  
TC.32700.066  
TC.32700.064  
TC.32700.062  
TC.32700.079  
TC.32700.077  
TC.32700.075  
Acer 4-port 6Gb/s SAS RAID Adapter (w/ mSAS-mSAS cable) Kit  
Acer 8-port 6Gb/s SAS RAID Adapter (w/ mSAS-mSAS cable) Kit  
Acer 16-port 6Gb/s SAS RAID Adapter (w/ mSAS-mSAS cable) Kit  
Acer Battery Backup Kit for Cache module in 8port/16port SAS RAID Card  
Acer Fibre Channel Storage Controllers  
TC.32300.028  
TC.32300.034  
TC.32300.042  
TC.34800.006  
Acer 8Gb/s Single Port Fibre Channel HBA Kit  
TC.32300.024  
TC.32300.026  
TC.33700.021  
Acer 8Gb/s Dual Port Fibre Channel HBA Kit  
Acer Cable Management Arm (2U/4U) Kit  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  

ACR Electronics Security Camera 19303 User Manual
Advantech Car Video System IPPC 9151 Series User Manual
Aiwa CD Player XR MR5 User Manual
Allied Telesis Network Router AR415S User Manual
Alphasonik Car Speaker PSW310X User Manual
Alpine Car Stereo System IVA D100 User Manual
American Standard Indoor Furnishings 0211008 User Manual
American Standard Indoor Furnishings 0321026 User Manual
Ask Proxima Projector Pro AV SX1 User Manual
Audiovox Automobile Electronics AS9233ST User Manual