Aarrow Fires Indoor Fireplace Becton 7 mk3 User Manual

Operating & Installation Manual  
The Becton MK 3  
Range of Gas Stoves  
(Becton 7 MK 3 Gas Stove)  
PLEASE RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE  
Aarrow Fires Ltd  
The Fireworks  
Bridport  
Dorset, DT6 3BE  
Great Britain  
FOR USE IN COUNTRIES  
GB & IE  
Tel. (44) 01308 427234  
Fax. (44) 01308 427441  
Rev 11  
Part No. AFS1125  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CONTENTS  
Page  
Page  
SERVICING  
INTRODUCTION  
Safety Notices  
Details of Pilot Assembly  
Door Trim  
18  
19  
19  
20  
20  
21  
21  
21  
22  
4
4
5
General Information  
Fire Door Glass & Seal  
Burner Assembly  
Regular Service  
Statutory Requirements  
OPERATING INSTRUCTIONS  
Technical Data  
6
6
Annual Service  
Fire Dimensions  
Cleaning Outer Services  
Cleaning Door Glass  
Fault Diagnosis  
Fitting the Lining Panels  
Arranging the Coals  
Lighting & Controlling The Fire  
7
8
9-10  
SPARE PARTS  
General Components  
Accessories and Options  
Notes  
INSTALLATION  
Installing The Fire  
Fitting The Feet  
23  
23  
11  
11  
24-25  
26-28  
Flue System  
11-13  
13  
Spare Parts List  
Fire Location  
GUARANTEE  
Lifetime Guarantee  
Customer Registration  
SERVICE RECORD  
Service Record  
Combustible Shelf Clearances  
Hearth Requirements  
Connecting The Gas Supply  
Pressure Test Sequence  
Fire Testing  
14  
29 & 31  
29  
15  
15  
15  
30  
31  
32  
16  
Lifetime Guarantee  
Final Factory Checklist  
Installation Check List  
17  
Becton Bunny & Becton 7 mk3 Gas stoves  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
INTRODUCTION  
References in this manual to British Standards and  
Statutory Regulations and Requirements apply only  
to the United Kingdom. For Ireland the rules in  
force must be used.  
Before installation, check that the local distribution  
conditions, nature of the gas, pressure and the  
adjustment of the appliance are compatible.  
The manual is an important part of the appliance  
and must by law be handed to the end user on  
completion of the installation.  
normal hygiene rules are followed.  
Always wash your hands before eating or  
drinking.  
• In the event of a gas emergency, consult the  
telephone directory and ask for your local  
gas supplier.  
_________________________________________  
GENERAL INFORMATION  
SAFETY NOTICES  
• Do not attempt to burn rubbish or any other  
material in this appliance.  
• This fire must only be operated with the fire  
door shut and secured.  
• Do not use the appliance if the glass is cracked or  
broken.  
• Do not make any unauthorised  
modifications to the appliance.  
• It is recommended that the fire be guarded  
to protect the young and infirm using a  
fireguard complying with BS8423:2002.  
Coal set -The coal set contains Refractory  
Ceramic Fibres (R.C.F), which are man  
made vitreous silicate fibres. Excessive  
exposure to these materials may cause  
temporary irritation to the eyes, skin and  
respiratory tract. Care must be taken when  
handling these items to ensure the release of  
dust particles is kept to a minimum. To  
ensure that the release of fibre from these  
items is kept to a minimum, during  
All materials, appliances and equipment used  
should be fit for their purpose, be of suitable  
quality and workmanship and should comply with  
the applicable British Standards.  
Before continuing any further with the installation  
of this appliance please read the following guide to  
manual handling.  
• Always obtain assistance when lifting the  
appliance.  
installation and servicing it is recommended  
that a vacuum cleaner fitted with H.E.P.A.  
filters is used to remove any dust, soot or  
any other debris accumulated in and around  
the appliance. This should be performed  
before and after the installation. It is  
recommended that any replacement item(s)  
are not broken up but sealed within a heavy  
duty polythene bag and clearly labelled  
"R.C.F. waste". This is not classified as  
"hazardous waste" and may be disposed of  
at a tipping site licensed for the disposal of  
industrial waste. Protective clothing is not  
required when handling these items but it is  
recommended that gloves are worn and  
• When lifting always keep your back  
straight. Bend your legs not your back.  
• Avoid twisting at the waist. It is better to  
reposition your feet.  
• Avoid upper body/top heavy bending. Do not  
lean forwards or sideways when  
handling the fire.  
• Always grip with the palms of your hands.  
Do not use fingertips for support.  
• Always keep the stove as close to the body as  
possible. This will minimise the cantilever  
action.  
• Use gloves to provide additional grip.  
4
Becton Bunny & Becton 7 mk3 Gas stoves  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INTRODUCTION  
IMPORTANT NOTICES  
Warning: THIS GAS APPLIANCE MUST BE  
SERVICED EVERY TWELVE MONTHS BY A  
QUALIFIED GAS ENGINEER.  
A qualified gas engineer must carry out the  
installation and servicing of this appliance in  
accordance with these instructions and in  
compliance with current Building Regulations.  
Such person must be a registered CORGI  
engineer.  
STATUTORY REQUIREMENTS  
This appliance is designed to run on natural gas  
only. Warning - Only use the appliance with the  
specified gas.  
The current Gas Safety (Installation and Use)  
Regulations (as amended).  
The Building Regulations for England and Wales  
2000 ref Approved Document J 2002 edition  
(issued by the DTLR).  
The fire is fitted with a safety device to shut down  
the appliance if there is inadequate flue draw. If the  
fire shuts down for no apparent reason check  
chimney and air inlets to the room. In all cases the  
fire must not be re-lit until the safety aspects have  
been checked by a qualified gas engineer.  
The Building Standards (Scotland) (Consolidation)  
Regulations.  
Please note the following;  
Detailed recommendations are outlined in the  
current issue of the following British Standards:-  
BS5440 parts 1 and 2, BS5871 part 1 and BS6891.  
• The safety device must never be put out of  
action.  
• Sealed components must not be interfered  
with.  
Any Manufacturer's Instructions must not be  
taken as overriding statutory requirements.  
• Servicing instructions and part identification  
numbers are given towards the back of the  
manual.  
_________________________________________  
• Only use genuine Aarrow parts for  
replacements.  
CERTIFICATION  
Ventilation, purpose built ventilation is not  
normally required for either appliance,  
normal adventitious room ventilation being  
sufficient.  
This appliance is CE certificated for performance  
and safety. Therefore, it is important that no  
alteration is made to the appliance.  
• Coal Set, see safety notice on page 4.  
Any alteration not approved by Aarrow Fires Ltd.  
will invalidate the guarantee.  
All surfaces except the control knob, the control  
door handle and control door are considered to be  
working surfaces.  
Warning: Under no circumstances must the fire  
be operated if the glass is cracked or broken.  
Warning: If it is known or suspected that an  
operational or ignition fault exists on the  
appliance, it must not be used until it has been  
investigated and corrected by a qualified gas  
engineer.  
Becton Bunny & Becton 7 mk3 Gas stoves  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATING INSTRUCTIONS  
TECHNICAL DATA  
FIRE DIMENSIONS  
Category I2H For use in GB and IE at a  
supply pressure of 20mbar  
Becton  
Bunny  
Natural Gas  
Becton 7  
Natural  
Gas  
Aeromatic  
AC13/112511  
(mod 334)  
Aeromatic  
AC13/112511  
(mod 334)  
Main Burner  
Injector  
Bray 82-700  
Bray 82-700  
Max. Heat  
Setting  
Heat Input  
(net)  
3.7 kW  
5.0 kW  
Fig. 2  
Gas Rate  
0.391m3/hour  
1.5mb  
0.529m3/hour  
3.5mb  
Cold Setting  
Pressure  
Min. Heat  
Setting  
Heat Input  
(net)  
2.4 kW  
3.3 kW  
Gas Rate  
0.254 m3/hour 0.349 m3/hour  
CLASS 4  
NOx CLASS  
CLASS 4  
6
Becton Bunny & Becton 7 mk3 Gas stoves  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATING INSTRUCTIONS  
3. Then rotate the rear edge until the top faces  
match up the angle faces at the rear of the fire.  
(See Fig. 3c) Repeat exercise for the left hand side.  
FITTING THE LINING PANELS  
Becton 7 only. The lining panels supplied are to be  
installed into the fire before the coal matrix is  
fitted. Note: The lining panels are reversible (brick  
or plain pattern)  
Ensure the appliance is cold.  
With the fire door open, the glass retaining frame  
and the coal set removed, proceed as follows:  
Do not force the linnings into position.  
1. Position the rear lining face down at the rear of  
the fire. Ensure the cutout faces the rear of the fire.  
Fig. 3c Fitting the side linings  
4. Rotate the rear lining to bring it vertical (Fig. 3d)  
Fig. 3a Positioning the rear lining  
Fig. 3d Rotating the rear lining  
2. Locate side lining in the right hand side of the  
fire. First position the tall edge into the radius at the  
front of the fire.(See Fig.3b below)  
5. Centre the assembly. Line up each end of the rear  
lining with the edges of the fixed matrix plate. (See  
Fig. 3e)  
Fig. 3e Liner panels assembled in the fire.  
Fig. 3b Fitting the R/H side lining  
Once the lining panels are fitted, arrange the coals.  
See “Arranging the coals” on page 8.  
Becton Bunny & Becton 7 mk3 Gas stoves  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATING INSTRUCTIONS  
ARRANGING THE COALS  
Step 3 Becton 7 only. Locate 2 off end coals each  
side of the base matrix. (See underside of coals for  
hand identification) (Fig 4c).  
Safety Notice - Please see SAFETY NOTICES  
ref. Coal set page 4.  
Warning: The coals and the coal matrices are  
fragile ensure they are handled carefully.  
Ensure location is correct. Do not force the  
matrix into position. If the coals and/or the coal  
matrices are damaged they must be replaced  
with genuine Aarrow replacement sets.  
Warning: An incorrect coal layout may cause  
soot to build up inside the fire and therefore  
invalidate the guarantee.  
Fig 4c  
Ensure the appliance is cold.  
Step 1 Place the base matrix on the matrix plate  
centrally between the end tabs of the location bar.  
(Fig 4a)  
Fig 4a  
Step 2 Place the rear matrix cut out section over  
the base matrix and centralise the assembly  
between the end tabs of the location bar. Ensure the  
rear matrix is pushed back against the location bar.  
(Fig 4b)  
Fig 4b  
8
Becton Bunny & Becton 7 mk3 Gas stoves  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATING INSTRUCTIONS  
LIGHTING & CONTROLLING  
THE FIRE  
Step 1c. Keep the control knob pressed in for a  
further 15 seconds and then release. The pilot will  
remain alight.  
Under no circumstance must the fire be operated if  
the glass is cracked or broken.  
If pilot does not remain alight repeat this procedure.  
Open the gas control access door situated at the  
bottom of the appliance. Always use the control  
door HANDLE.  
Please note that when purging the gas supply it is  
usual to have to keep the control knob depressed in  
the spark position for longer periods of time.  
Step 1a. To ignite the pilot push the control knob in,  
turn anti-clockwise towards the spark position and  
hold in for 15 seconds. (Fig 5a)  
Step 2. To ignite the main burner, rotate the control  
knob anti-clockwise to the HIGH position (fig 5c)  
The pilot can be viewed through the L/H & centre  
front slots in the base matrix.  
Fig 5c  
For maximum heat output leave the control knob at  
the high position  
Fig 5a  
For minimum heat output, rotate the control knob  
clockwise to the LOW position. (Fig 5d)  
Step 1b. Keep the control knob pressed in and turn  
anti-clockwise to the pilot position. (Fig 5b)  
Fig 5b  
Becton Bunny & Becton 7 mk3 Gas stoves  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATING INSTRUCTIONS  
Step 4. To extinguish the pilot, turn the control knob  
to the OFF position. (Fig 5f)  
Incorporated into the pilot assembly is a flame  
failure device designed to shut off the gas supply in  
the event of the pilot flame being extinguished  
while the fire is unattended.  
Should the pilot flame blow out accidentally or  
intentionally whilst the fire is running, no attempt  
should be made to re-light the gas for at least  
three minutes.  
To restart the fire turn the control knob to the off  
position and repeat the lighting & controlling the  
fire instructions.  
Fig 5d  
The flame failure device is a safety feature required  
by law and must not be put out of action by the  
installer. If this device or any of its parts are to be  
replaced, only original manufacturer's parts are to  
be used.  
Repeated operation of the flame failure device  
indicates that there maybe a problem with the flue  
draw. In this situation no more attempts at  
operating the appliance should take place and your  
qualified gas engineer should be contacted to  
investigate and rectify the problem.  
Fig 5e  
Step 3. To turn the main burner off while keeping  
the pilot alight, rotate the operating knob back to  
the PILOT position. (Fig 5e)  
Fig 5f  
10  
Becton Bunny & Becton 7 mk3 Gas stoves  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
chimney must be at least 3 metres and when warm  
the flue draught should be between 0.05 and 6mb  
(0.5mm to 6mm water gauge).  
INSTALLING THE FIRE  
Your CORGI qualified gas engineer should install  
the fire in accordance with the following  
regulations and standards:-  
The Gas Safety (Installation and Use) Regulations  
1998 (as amended).  
The Building Regulations for England and Wales  
2000 ref; Approved Document J 2002 edition  
(issued by the DTLR).  
The Building Standards (Scotland) (Consolidation)  
Regulations.  
The Bunny requires a minimum flue size of 100mm  
(4 inches) and the Becton 7 requires a minimum  
flue size of 125mm (5 inches). If the stove is being  
connected to a chimney with an internal flue size  
greater than 225mm (9 inches) diameter or 200 x  
200mm square, a 125mm (5 inches) diameter  
stainless steel flexible flue liner complying with BS  
715 should be installed in the flue.  
If a new chimney is being provided it should fully  
comply with the relevant Building Regulation  
Requirements and BS 5440: Part 1. Suitable types  
of chimney include the following.  
BS5440 parts 1 and 2 1990, BS5871 And these  
Installation Instructions.  
Warning: Failure to comply with the  
regulations, requirements, or these instructions  
will invalidate the guarantee and could have  
hazardous consequences.  
• Masonry chimney built with clay or concrete lin-  
ers, or a chimney block system meeting Building  
Regulations.  
• Precast concrete gas flue block complying with  
BS 1289: Part 1  
Please note that in tight recesses the gas supply  
point may be inaccessible. Therefore it may be  
necessary to connect the pipe for the gas supply to  
the fire before installing the fire into its recess.  
Factory made metal chimney complying with BS  
715 (often called "Twin wall Class 2 chimney") or  
Factory made metal insulated chimney comply-  
ing with BS 4543: Part 2 (often called "Class 1 pre-  
fabricated metal chimney"). To ensure the flue  
gases are kept warm an insulated chimney system  
should be used if the chimney is positioned outside  
the building.  
FITTING THE FEET  
Care should be taken when fitting the feet not to  
damage the painted surfaces of the fire.  
• The feet (4 off) are positioned in each corner of  
the fire base using the washers and screws  
provided.  
The flue must be terminated with a suitable  
chimney pot or cowl and the chimney or flue shall  
be swept prior to installation unless the chimney is  
clean and unobstructed.  
Tools required: A no. 2 pozidrive screwdriver.  
FLUE SYSTEM  
The flue and chimney installation must be  
carefully checked by a competent person before  
fitting the stove to ensure it is suitable and will  
work safely. The flue must also pass a Flue flow  
test (smoke test) to BS 5440: Part 1.  
For advice on flues and chimneys contact;  
NACE (National Association of Chimney  
Engineer): telephone 0800 0924019  
The stove must be connected to a suitable and  
efficient flue that provides a good updraught to  
safely take the products of combustion (fumes)  
from the stove outlet to the outside air. To ensure a  
good updraught it is important that the flue gases  
are kept warm and that the flue size suits the stove.  
or  
The termination of the outlet at the top of the flue  
also needs to comply with the Building  
Regulations. The minimum effective height of the  
NACS (National Association of Chimney  
Sweeps): telephone 01785 811732  
Becton Bunny & Becton 7 mk3 Gas stoves  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
The Becton gas stove is designed so that the flue  
can be fitted to either the top or the rear of the  
Provide a minimum vertical height of 600mm of  
flue from the height of the rear flue outlet. See  
figure 7b.  
appliance.  
Closure Plate  
Fit the flue spigot and blanking plate for either top  
or rear flue outlet in accordance with figure 6a or  
6b (below).  
#Connect the flue spigot to the rear outlet.  
#Connect a flue extension to the spigot.  
#Fit the closure plate in fireplace.  
#Position the fire so the flue extension passes  
through the hole in the closure plate.  
#Ensure all joints are suitably sealed.  
See Figure 7c.  
TOP FLUE  
Provide a minimum vertical height of 600mm of  
flue measured from the top of the appliance.  
See Figure 7d.  
Move the fire, with flue spigot in place, into  
position under the flue and seal the spigot/flue  
connection with fire cement. (Ref. Fig. 6c).  
Lock the blanking plate in place by rotating anti-  
clockwise and tighten by tapping gently with a  
block of wood and mallet. Fit the spigot to the  
unused opening in the same way. The units are  
It is recommended that a smoke test is performed  
inside the fire to ensure that adequate flue draw is  
evident.  
sealed by the attached gaskets.  
Fig 6c  
REAR FLUE  
Fig 7a  
Open Hearth  
Fit and seal a ‘T’ section (with soot box) directly  
into the flue spigot. The maximum horizontal  
section allowed is 150mm.  
12  
Becton Bunny & Becton 7 mk3 Gas stoves  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
non- combustible closure plate,  
non- combustible closure plate,  
incorporating access for cleaning debris.  
incorporating access for cleaning debris.  
Fig. 7d.  
Fig. 7b.  
FIRE LOCATION  
The appliance must not be installed in a room or  
space, which contains a bath or shower.  
This fire is designed for use with either top or rear  
flue outlets and must be mounted on a hearth with  
a minimum of 12mm non-combustible material  
thickness.  
There must be a minimum of 200mm clearance  
from the sides of the fire to any combustible  
sidewalls. Fig7a.  
For clearance from the top of the fire to any  
combustible shelf. Fig 7b. (See Graph 1).  
There must be a minimum of 230mm from the  
rear of the fire to any combustible back wall.  
Fig 7b.  
With a Non-combustible back wall the fire can be  
pushed back until the top diverter touches the wall,  
although to improve access and air circulation a  
minimum distance of 100 mm is recommended.  
Fig 7c.  
Fig. 7c  
Reference non-combustible side walls a minimum  
of 100mm is recommended.  
Do not place any furniture or furnishings (including  
curtains) within 1 metre of the fire.  
Becton Bunny & Becton 7 mk3 Gas stoves  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
The minimum height from the extreme top surface of the fire to the underside of a shelf or other projection  
made of wood or any other combustible material is shown on graph 1.  
Graph 1.Combustible Shelf Clearances  
The recommended minimum height from the extreme top surface of the fire to the underside of a  
non combustible shelf is 100mm.  
14  
Becton Bunny & Becton 7 mk3 Gas stoves  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
To check the pressure to the burner it is  
necessary to ignite the appliance and set to 'high  
rate'.  
This is carried out by following instructions on  
pages 9 and 10.  
HEARTH REQUIREMENTS  
To comply with current Building Regulations the  
fire must stand on a fireproof hearth, which has an  
upper fireproof layer of 12mm non-combustible  
material. If the rear of the fire is to be pushed up  
against a surface it must be of a non-combustible  
material.  
The hearth must protrude at least 25mm in front of  
the glass window and 150mm either side.  
The hearth must not be capable of inadvertent  
covering by a carpet or rug. This should be  
achieved by either:  
Cold setting pressures are in the Technical data  
section on page 6.  
The pressure test point is located through the hole  
in the valve bracket marked 'test point',  
See Fig.8 below.  
The hearth being 50mm above the level of the room  
floor. A 50mm high fender or kerb being fixed  
around the edge of the hearth.  
CONNECTING THE GAS SUPPLY  
Pressure test  
point  
Once the fire is in place it is then possible to  
connect the gas supply. The gas supply point is  
located at the rear of the appliance and should be  
connected in accordance with the following  
requirements.  
Check that the appliance is suitable for the gas  
supply; refer to data labels on packaging and/or the  
fire for gas type. Note: Natural gas and Propane  
(LPG) models are not interchangeable.  
Fig. 8  
TEST SEQUENCE  
ENSURE FIRE IS OFF  
1. Open control door.  
2. Loosen test point screw.  
The gas installation must be in accordance with the  
current issue of BS6891.Gas supply pressure at the  
fire should be 20mbar for natural gas.  
The gas supply should be connected with the  
1/4"BSP nut and olive with 8mm tubing.  
3. Connect hose of test equipment to test point  
through the test point hole in bracket. (If necessary  
open fire door and remove coal set, base matrix  
plate and heatsheild. Close door on completion)  
4. Turn on fire and set flame on high.  
5. Take reading.  
6. Turn fire off.  
7. Remove test equipment hose.  
8. Re-tighten test screw (If necessary replace  
heatsheild, matrix plate and coal set.  
A maximum pipe run of 1.5 meters (or 5 feet)  
should be adhered to and copper tubing may be  
used provided a distance of 25mm is maintained  
between pipe-work and any surface of the fire. A  
gas service cock should be fitted adjacent to the  
fireplace to enable safe removal of the appliance for  
servicing. After fitting the supply, operate the gas  
cock (supplied) and check all joints up to the  
termination of the supply pipe for gas tightness  
using a soap/water solution and the pressure drop  
method.  
Becton Bunny & Becton 7 mk3 Gas stoves  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
Warning: The spillage monitoring system is a  
safety feature required by law and must not be  
adjusted or put out of action by the installer. If  
the spillage monitoring system or any of its parts  
are to be replaced, only original manufacturers  
parts are to be used.  
FIRE TESTING  
Flame failure device testing  
Step 1 Ignite the appliance in accordance with  
page 9 and run for 60 seconds.  
Step 2 Turn the appliance off to extinguish the  
pilot, listen for a snap at the control valve. This  
should occur within 60 seconds of the pilot flame  
being extinguished. The snap sound will be the  
magnet disengaging, and thus shutting off the flow  
of gas to the pilot and burner.  
Spillage Test  
A qualified gas engineer should Perform a spillage  
test as follows:  
Step 1. Close all doors and windows.  
Step 2 Light the appliance and set to the high rate.  
Step 3. Allow fire to warm up for 10 minutes.  
Fig. 9  
Step 4. Position the smoke match at the back of the  
fire centrally beneath the draught diverter as shown  
in Fig 9.  
Note: The fire will give off non-toxic fumes when  
first used. This is perfectly normal and is due to the  
paint curing, it will disappear after the first few  
hours. Once the spillage test is complete open  
windows and doors to ventilate the area.  
All of the smoke should be drawn into the fire.  
If this does not occur the appliance must be  
disconnected and the flue checked.  
Step 5. If there is an extractor fan in any room,  
this must be turned on and any doors between it  
and the fire left open, repeat the spillage test.  
Repeated operation of the spillage monitoring  
system indicates that there maybe a flue draw  
problem. In this situation no more attempts at  
operating the appliance should take place and your  
gas engineer should be contacted.  
16  
Becton Bunny & Becton 7 mk3 Gas stoves  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION CHECK LIST  
CHECKLIST  
Hearths, Fireplaces, Flues and chimneys  
This checklist is to ensure hearths, fireplaces, flues and chimneys are satisfactory, and to show what you have done to comply with the  
requirements of The Building Regulations 2000 Approved Document J 2002.  
1. Building address, where work has been carried out.......................................................................................................................................  
.........................................................................................................................................................................................................................  
2. Identification of hearth, fireplace chimney or flue  
3. Firing capability: solid fuel/gas/.  
4. Intended type of appliance.  
State model and output.  
5. Ventilation provisions for the appliance:  
State type and area of permanently open vents.  
6. Chimney or flue construction  
a) State the type or make and whether new or existing.  
b) internal flue size (and equivilent height, where  
calculated - natural draught gas appliances only).  
c) If clay or concrete flue liners used confirm that they are  
correctly jointed with socket end uppermost and  
state jointing materials used.  
d) If an existing chimney has been refurbished with a  
new liner, type or make of liner fitted.  
e) Details of flue outlet terminal and diagram reference.  
Outlet Details:  
Complies with:  
f) Number and angle of bends.  
g) Provision for cleaning and recommended frequency.  
7. Hearth. Form of construction. New or existing?  
8. Inspection and testing after completion  
Tests carried out by:  
Tests and results  
Flue  
visual  
inspection  
sweeping  
coring ball  
smoke  
Appliance (where included) spillage  
I/we the undersigned confirm that the above details are correct. In my opinion, these works comply with the relevant requirements in  
Part J of Schedule 1 to the Building regulations.  
Print name and title....................................................................................................Profession..........................................................................  
Capacity......................................................................................................................Telephone..........................................................................  
Address............................................................................................................................................................Postcode.......................................  
Signed........................................................................................................Date.................................  
Registered membership of..(e.g. CORGI, OFTEC, HETAS, NACE, NACS)............................................  
Becton Bunny & Becton 7 mk3 Gas stoves  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SERVICING  
DETAIL OF PILOT ASSEMBLY  
It is strongly recommended to leave the pilot on  
permanently. This will keep the fire and its  
components, including the ceramic coal set in a  
warmer state and assist ignition to the burner.  
This in turn will reduce condensation in the  
chimney and any associated flue problems.  
The pilot can be viewed through the L/H & centre  
front slots in the base matrix.  
Fig. 10  
18  
Becton Bunny & Becton 7 mk3 Gas stoves  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SERVICING  
Step 3 The trim will now lift off the remaining 2  
tabs. See Fig. 11d.  
DOOR TRIM  
Becton Fire doors are fitted with a brushed steel  
finish trim as standard. The trim is secured using 3  
off tabs and located in the slot section of the trim  
and secured with 3 off nuts. (See Fig. 11a below.)  
Fig 11d  
Step 4 Repeat the above steps in reverse to replace  
the trim.  
Fig. 11a Location of the 3 off tabs  
FIRE DOOR GLASS & SEAL  
If necessary the glass and seal can be removed as  
follows:  
Note! To fit a tracery the trim must first be  
removed. The fire door can only be fitted with one  
item at a time.  
Ensure the appliance is cold.  
Step 1 Open the fire door.  
REPLACEMENT OF THE DOOR  
TRIM  
Ensure the appliance is cold.  
Step 1 Remove the fire door.  
This is carried out by opening the door (secured  
with a magnet) and lifting it off its hinges.  
Step 2 The glass frame is secured using M5 screws.  
Remove all but the bottom 2 screws. See Fig. 12  
below.  
Fig. 12 Removing the Glass Frame  
Step 3 Loosen the two remaining screws to enable  
you to lift off the glass frame and the glass and  
gasket assembly together.  
Fig 11b Lifting the door off its hinges  
Step 2 Place the door on a flat surface and remove  
the single tab. The tracery can now be removed.  
(See Fig. 11c below)  
To re-fit the glass & seal. First ensure sealing faces  
are clean and free from dust. Then follow the  
removal steps in reverse.  
Note! The screws must be firmly secured to reform  
the seal.  
Fig. 11c Untightening the single tab  
Becton Bunny & Becton 7 mk3 Gas stoves  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SERVICING  
BURNER ASSEMBLY  
REGULAR SERVICE  
To remove the burner assembly proceed as  
follows;  
See "SAFETY NOTICES" ref coal set page 4.  
Any soot debris should be removed from the fuel  
bed regularly by the end user.  
Ensure the appliance is cold.  
Step 1 Turn off the gas supply at the gas service  
Ensure the appliance is cold.  
cock.  
Step 1 Isolate the gas supply from the fire.  
Step 2 Disconnect the supply inlet pipe at the  
rear of the fire.  
Step 2 Open the fire door and remove the glass  
frame and the glass/gasket assembly (Note  
the fire door is secured with a magnet).  
Step 3 Open door and remove the glass frame  
and glass gasket assembly.  
Step 3 Carefully remove and clean the coal set  
Step 4 Remove the coal set and fire box linings.  
of any soot deposits with a soft a brush.  
Step 5 Remove the matrix location plate. Undo  
Step 4 Remove any soot deposits from inside  
the fire using a vacuum cleaner.  
(See “Safety Notices” under ‘Coal set’ on  
page 4).  
the three retaining nuts and lift out.  
Step 6 Remove the heat shield. Undo the two  
retaining nuts located on the left hand side  
of the shield. Slide the shield backwards  
and lift out carefully. Do not damage the  
covering.  
Step 5 Replace the coal set. See assembly  
procedure on page  
Step 6 Replace glass/gasket assembly and glass  
Step 7 Remove the gas valve control knob. Pull  
frame.  
off.  
Step 7 Close fire door.  
Step 8 Remove the 15mm retaining flange nut.  
17mm socket.  
Step 9 Remove two off posi-drive screws just  
inside the fire door aperture.  
The burner assembly will now lift out.  
After replacement of burner assembly, ensure  
that a check on the gas tightness of any new  
joint is carried out.  
20  
Becton Bunny & Becton 7 mk3 Gas stoves  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SERVICING  
Step 13 Replace glass/gasket and glass frame and  
ANNUAL SERVICE  
close the fire door.  
THIS GAS APPLIANCE MUST BE SERVICED  
EVERY TWELVE MONTHS BY A QUALIFIED  
GAS ENGINEER.  
Step 14 Carry out spillage test as per instructions  
on page 16.  
CLEANING OUTER SURFACES  
See "SAFETY NOTICES" ref coal set page 4.  
To clean the outside first the appliance must be  
cold.  
Ensure the appliance is cold.  
Step 1 Isolate the gas supply to the fire using  
The outside finish of the fire is a durable high  
temperature paint, this will give off a slight odour  
during the first few days of operation. It is best  
cleaned by using a soft brush. Do not allow  
moisture to remain on the fire whilst cold or surface  
rust may occur.  
the gas cock supplied at installation.  
Step 2 Open the fire door, (Held closed using a  
magnet).  
Step 3 Remove the glass frame and the glass/  
gasket assembly.  
CLEANING THE GLASS  
Step 4 Carefully remove and clean the coal set of  
any soot deposits using a soft brush.  
To clean the glass the appliance must be cold.  
Step 5 Carefully remove and clean the firebox  
Step 1 Open the fire door. (This is held closed using  
a magnet)  
linings. Where necessary.  
Step 6 Inspect the chimney and flue terminal  
ensuring they are in good working order  
and sweep as necessary to ensure no  
debris blocks the flue. Please note  
periodic chimney sweeping is vital to gas  
fire maintenance.  
Step 2 Remove the glass frame and the glass/gasket  
assembly (See page 19).  
Take care not to damage the glass or gasket when  
cleaning.  
Step 3 Replace glass frame and the glass/gasket  
assembly. Close the fire door.  
Step 7 Remove matrix location plate and valve  
heat shield. Clean any soot deposits from  
inside the fire using a vacuum cleaner.  
See “Safety notes”on page 4.  
Step 8 Inspect the pilot assembly to ensure that it  
is clean, unobstructed and in good order.  
Step 9 Check system for gas soundness.  
Step 10 Replace heat shield and matrix location  
plate.  
Step 11 Replace fire box linings.  
Step 12 Replace coal set.  
Becton Bunny & Becton 7 mk3 Gas stoves  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SERVICING  
FAULT DIAGNOSIS  
START  
Does the pilot  
ignite?  
Does the pilot  
stay alight?  
Does the main  
burner light?  
Yes  
Yes  
Yes  
Fire satisfactory  
No  
No  
No  
Is the gas supply  
turned on?  
Is the main  
injector blocked?  
Is their air in the  
system?  
No  
Yes  
Yes  
Purge system  
Turn gas on  
Clean and  
replace as  
necessary  
Yes  
No  
No  
Is the supply  
pressure correct?  
Is the  
thermocouple  
o.k.?  
Is the flue  
blocked?  
Carry out  
smoke test  
No  
No  
Correct  
Correct  
pressure  
alignment or  
replace  
Yes  
Yes  
No  
Is pilot injector  
obstructed?  
Confirm supply  
pressure is correct  
Is their a spark at the  
electrode?  
No  
Yes  
Clean  
Check piezo  
igniter  
No  
Yes  
Has spillage  
monitoring  
system been  
activated?  
Check to ensure the  
pilot assy is not  
obstructed or faulty  
No  
Check all pipe  
connections  
check main valve  
magnet  
Yes  
Investigate flue  
systems  
22  
Becton Bunny & Becton 7 mk3 Gas stoves  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SPARE PARTS  
GENERAL COMPONENTS  
Spare parts can be obtained by contacting the  
original supplier of the fire or Aarrow Fires.  
Fire Body Ancillary Components.  
Only use genuine Aarrow parts.  
Add on Canopies  
ACCESSORIES AND OPTIONS  
Bunny - Low available only  
Size: 400mm wide x 345mm deep.  
Raises the stove approximately 140mm.  
Paint- Matching aerosol paint to tone in any  
connecting flues, pipes or surrounding metalwork  
Tracery or Trim - Note: When fitted one replaces  
the other.  
Becton 7 - High and low are available.  
Size:-480mm wide x 345mm deep  
High. Raises the stove approximately 240mm  
Low. Raises the fire approximately 180mm.  
Becton Bunny & Becton 7 mk3 Gas stoves  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NOTES  
24  
Becton Bunny & Becton 7 mk3 Gas stoves  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NOTES  
Becton Bunny & Becton 7 mk3 Gas stoves  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SPARE PARTS  
Bunny  
mk3  
Part No.  
Becton 7  
mk3  
Part No.  
Visual Aid  
(not to scale)  
Part Description  
1. Becton 7 mk3  
Coal Set  
AFGS1075  
-
1a. Becton Bunny  
mk3 Coal Set  
AFGS1074  
-
2. Co-pilot assembly  
3. Elbow Injector  
AFGS089  
AFGS090  
AFGS091A  
AFGS1073  
AFS047  
AFGS089  
AFGS090  
AFGS091  
AFGS1073  
AFS047  
4. Gas Control  
Valve  
5. Magnetic Catch  
for mk3 Gas Fires.  
6. Hinge Kit To Fit  
Either Door.  
Comprises 2 Hinges  
& 4 Fixings Per Set.  
26  
Becton Bunny & Becton 7 mk3 Gas stoves  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SPARE PARTS  
Bunny  
mk3  
Part No.  
Becton 7  
mk3  
Part No.  
Visual Aid  
(not to scale)  
Part Description  
7. Control Door  
Handle Assembly  
AFGS1085  
AFGS1085  
AFGS1077  
8. Burner & Fixing  
AFGS1076  
AFGS080  
AFS094A  
AFGS1078  
9. Pipe Set Complete  
With Connectors  
AFGS080  
AFS095  
10. Decorative Door  
Surround (Trim)  
11. Fire Door  
Assembly complete  
with Magnet Lock  
and Trim  
AFGS1079  
12. Glass  
Replacement Kit  
with Gasket &  
Fixings.  
AFGS1080  
AFGS064  
AFGS1081  
AFGS010  
13. Hotplate  
14. Flue Outlet  
Spigot  
AFGS1082  
AFGS1083  
Becton Bunny & Becton 7 mk3 Gas stoves  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SPARE PARTS  
Bunny  
mk3  
Part No.  
Becton 7  
mk3  
Part No.  
Visual Aid  
(not to scale)  
Part Description  
15. Becton 7 mk3  
Lining Kit  
-
AFGS1072  
AFGS093  
16. Large Ceramic  
Panel  
AFGS093  
17. Medium  
Ceramic Panel  
AFGS094  
AFGS094  
18. Small Ceramic  
Panel  
AFGS1084  
AFGS1084  
19. Gas Tap  
20. Manual  
AFGS025  
AFS1125  
AFGS025  
AFS1125  
21. Feet and Fixings  
AFS1013  
AFS997  
AFS1013  
AFS997  
22. Aarrow Fires  
Gauntlet Gloves  
28  
Becton Bunny & Becton 7 MK3 Gas stoves  
Download from Www.Somanuals.com. All Manuals Search And Download.  
GUARANTEE  
GUARANTEE  
All Guarantee periods commence on the date of  
purchase and are non-transferable.  
Once again we would like to thank you for buying  
a Becton fire.  
Our Lifetime Guarantee is offered as an addition to  
your statutory rights.  
When you buy an Aarrow Fire, you are not only  
buying a first class appliance - you are buying a  
commitment from us to look after you and your  
appliance.  
If you think your fire is not working correctly or in  
the event of a breakdown, please call your local  
dealer.  
The Becton Gas Stoves come with a  
When you contact them, they will want to know:  
Lifetime Guarantee against splitting or  
cracking of the main body. The main body being  
defined as the steel outer casing and items fixed  
immovably to the casing. All other parts are  
covered by a one-year no-quibble parts Guarantee.  
1.Your Name, Address/Post Code and Telephone  
Number  
2.Serial Number  
3.Clear and concise details of the fault  
This Guarantee shall not apply to any part that has  
been altered in any way, or which in our judgment  
has been subjected to misuse, neglect, accident,  
abuse and fair wear and tear.  
CUSTOMER REGISTRATION  
This Guarantee shall not include or extend to paint,  
glass or coal matrix and does not cover installation  
and operational related problems such as use of  
unapproved fuel, down draft or spillage caused by  
environmental conditions and inadequate  
ventilation.  
See card enclosed  
To guarantee the very best in after-sales service,  
do not forget to complete and return your  
Customer Registration Card within 14 days (a  
stamp is required).  
Claims are not valid where the installation does  
not conform to local Building Regulations.  
Just complete the form and return it to us to:  
1. Benefit from our Lifetime Guarantee.  
2. Register your appliance for a full year's Parts  
Guarantee.  
The Guarantee is conditional upon the appliance  
being serviced and checked annually by a qualified  
gas engineer.  
Please contact us direct 01308 427234 if no  
Customer Registration Card is included.  
The Manufacturers decision shall be final.  
If your appliance proves to be defective as a  
result of faulty materials or workmanship  
during guarantee, we will repair or replace it  
FREE OF CHARGE as long as the fire has been  
installed according to the these instructions and  
by a CORGI Registered fitter, who has  
completed and signed the Installation Check  
List on page 17. The fire must also be serviced in  
accordance with these instructions and the  
record of Annual service on page 30 should be  
completed by your service engineer.  
Becton Bunny & Becton 7 mk3 Gas stoves  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SERVICE RECORD  
Company  
Work Carried Out  
Signature  
Date of Visit  
Should you have any questions about your Becton Gas Stove that is not covered in this manual please con-  
tact your Aarrow retailer.  
Please keep all repair receipts safely.  
Please ensure you have this manual available when an engineer visits as they will complete the service record  
chart.  
30  
Becton Bunny & Becton 7 mk3 Gas stoves  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Lifetime Guarantee  
For your peace of mind  
Aarrow Fires gives a Lifetime Guarantee against manufacturing defects of the main  
body* of its Becton range of fires. Additionally, all other parts are covered by a one  
year no quibble replacement guarantee. This guarantee covers replacement of the item  
only and does not extend to any other costs, including labour, incurred in its replace-  
ment. Documentation must be retained and produced in the event of a warranty claim.  
This guarantee specifically does not cover accidental damage, misuse, wear & tear.  
The use of non Aarrow replacement parts will invalidate your warranty. For full details  
contact your local Aarrow dealer. All guarantees are in addition to your statutory  
rights. Please see page 29 for further information regarding the guarantee.  
*The main body defined as the steel outer casing and items fixed immovably on to this casing.  
No fears and no tears with  
The Becton  
Family  
Becton Bunny & Becton 7 mk3 Gas stoves  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FINAL FACTORY CHECK LIST  
Model..................................  
Serial No.............................  
I’ve checked it  
and it’s O.K.  
QUALITY  
FINISH  
COAL SET  
REGISTRATION CARD  
LINING SET  
Assembled by.............................  
Checked by ................................  
FLUE OUTLET  
HOTPLATE  
OPERATING INSTRUCTIONS  
GAS COCK  
FEET & FIXINGS  
Please ensure the enclosed registration card is completed and returned to Aarrow Fires and the following  
information completed for your own information.  
Date of Purchase....................................  
Name and address of supplier.......................................................................  
.......................................................................................................................  
.......................................................................................................................  
* Please ensure installer completes INSTALLATION CHECK LIST details  
on page 17 of this manual.  
BK027  
Download from Www.Somanuals.com. All Manuals Search And Download.  

2JANE Refrigerator HTS GS1 User Manual
ADC Laser Level P 80 412 User Manual
Advantek Networks Network Card AWN MIMO 54RA User Manual
Agri Fab Lawn Aerator 45 03431 User Manual
Aiphone Home Security System JB DVF HID User Manual
Asus Cell Phone P525 User Manual
Audiovox Remote Starter APS 2K4 User Manual
Avocent Network Card EVR1500 AM User Manual
Avocent Network Card Single port KVM over IP switch User Manual
BC Speakers Speaker 15TBX100 User Manual