RDM-2DC Dual DC Dimmer Module 1920W, 0-10 VDC (x2)  
The RDM-2DC Dual DC Module (FG606-61) is a 1920 W module used for the  
Caution: Pre-Installation Notes  
dimming of fluorescent ballast loads. It uses a 0 to 10 VDC current sinking for  
use with four-wire ballasts. It is designed for use with the RDA series of  
enclosures, in an AMX Lighting™ modular digital dimming system. The module’s  
120 and 277 VAC ratings are CE, UL, and C-UL approved.  
All Class 1 wiring must be connected to proper terminals.  
All control wiring must be connected to proper terminals.  
Disconnect power while installing or connecting the unit.  
Keep top and bottom air vents clear at all times.  
Use low-voltage wires with a 300 volt rating or greater.  
Use field installed copper conductors.  
All electrical ratings are for continuous duty.  
For indoor use only.  
Test loads for shorts before connecting.  
This module may require extra power from the AXlink connection or an  
external power supply connected to the control card.  
Mounting  
points  
Relay  
- out (LV)  
Low-voltage  
+ out (LV)  
Relay  
High  
voltage  
Load out  
Line in  
Connecting the RDM-2DC to the AMX Lighting Master  
Pin 4 (GND)  
Pin 3 (RLY)  
Pin 2 (DIM)  
High  
voltage  
Line in  
Load  
out  
Pin 1 (+12 V)  
RDM-2DC 4-pin module connector  
GND  
- out (LV)  
+ out (LV)  
Low  
voltage  
3 (-)  
2 (DIM)  
1 (+)  
Fuses  
4-pin plug from RDM series module  
Note: The 4-pin plugs from the module connector to the 4-pin  
connector on the master (black plug cover facing up).  
FIG. 2 Connecting the RDM-2DC and AMX Lighting Master  
Lighting Application Drawings  
Low-voltage control  
wiring: 4-pin  
connector to AMX  
Lighting master  
controller  
Neutral  
Ballast  
Load  
Florescent  
Ballast  
Neutral  
-
Line in (HOT)  
+
FIG. 1 RDM-2DC  
The fuses protect the dimming  
circuit from a low impedance load.  
RDM-2DC UL and C-UL Ratings  
120 VAC, 50/60 Hz, 1920 W  
277 VAC, 50/60 Hz, 1920 W  
Control Out: 50 mA, 12 VDC sinking  
The fuse will blow if it were  
incorrectly wired  
Catastrophic ballast failure  
Reversing switched and  
dimmed circuits  
Circuit breaker  
panel  
Suggested Dimmed Loads  
Reversing dimmed and  
line circuits.  
Four-wire dimmable ballasts, like Advance Transformer Mark VII™ or the  
Energy Savings SuperDim™ series  
The dimmed output must be  
connected to a high impedance  
load.  
Specifications  
Dimensions (HW): 10" x 2.75" (25.4 cm x 6.99 cm)  
Non-phase dependant  
FIG. 3 RDM-2DC application wiring  
Use wires rated at 75°C (167°F)  
Torque terminals to 20 in-lbs. (2.3 N/M)  
Max. wire size: 10 AWG (4 mm²)  
Wire stripping length: 0.28" (7 mm)  
Weight: 2.6 lbs. (1.180 kg)  
Warning: Failure to ground the ballast may cause ballast failure  
BTU/hr: 150  
Control current: 125 mA @ 12 VDC per control port  
For full warranty information, refer to the AMX Instruction Manual(s) associated with your Product(s).  
7/08  
93-606-61  
REV: A  
©2008 AMX. All rights reserved. AMX and the AMX logo are registered trademarks of AMX.  
AMX reserves the right to alter specifications without notice at any time.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

3D Connexion Two Way Radio 7906 User Manual
Abocom Network Router WAP354H User Manual
Acer Network Card ISDN P10 User Manual
Acu Rite Thermometer 00591W User Manual
ADC Network Card Network Unit User Manual
Aiphone Intercom System TC MB User Manual
Airlink101 Security Camera AIC1620W User Manual
Alto Shaam Oven 1200 S Series User Manual
Atlantis Land Switch AO2 F5P User Manual
Atlona Car Video System AT DIS7 HD User Manual