T3SU 300
T3 Service Unit
USER MANUAL
1200217L1
T3SU 300
1200217L2
1200218L1
1200219L1
T3SU 300 with Internal Modem
HSSI DTE Interface Card
V.35 DTE Interface Card
61200217L1-1B
December 1998
Download from Www.Somanuals.com. All Manuals Search And Download.
ABOUT THIS MANUAL
This manual is arranged so you can quickly and easily find the information
you need. The following is an overview of the contents of this manual:
•
Chapter 1, Introduction, familiarizes you with T3 networks and T3SU 300
highlights and gives a brief explanation of options that may be purchased
for use with the T3SU 300.
•
Chapter 2, Installation and Operation, describes the T3SU 300 connectors
(pin assignments are given in Appendix A), provides installation instruc-
tions, and explains how to operate your T3SU 300 using the terminal
interface.
•
Chapter 3, Configuration, explains how to access the T3SU 300 Configu-
ration menu, describes selections made in the Configuration menus, and
provides a menu tree of all of the available Configuration options.
•
•
Chapter 4, Status, describes each field of the Status menu.
Chapter 5, Statistics, explains how to access statistical information for the
T3SU 300 and describes each field.
•
•
Chapter 6, Diagnostics, explains how to diagnose problems using loop-
back and BERT tests.
Chapter 7, Applications, provides examples of some common T3SU 300
applications. This chapter includes network diagrams as well as configu-
ration tables for each example.
•
•
•
Appendix A provides pinouts for the T3SU 300 connectors.
Appendix B contains product specifications.
Appendix C is a list of acronyms and abbreviations used in this docu-
ment.
•
Appendix D is a glossary.
iii
Download from Www.Somanuals.com. All Manuals Search And Download.
Notes provide additional useful information.
Cautions signify information that could prevent service interrup-
tion.
Warnings provide information that could prevent damage to the
equipment or endangerment to human life.
IMPORTANT SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS
When using your telephone equipment, please follow these basic safety precautions
to reduce the risk of fire, electrical shock, or personal injury:
1. Do not use this product near water, such as near a bath tub, wash bowl, kitchen
sink, laundry tub, in a wet basement, or near a swimming pool.
2. Avoid using a telephone (other than a cordless-type) during an electrical storm.
There is a remote risk of shock from lightning.
3. Do not use the telephone to report a gas leak in the vicinity of the leak.
4. Use only the power cord, power supply, and/ or batteries indicated in the manual.
Do not dispose of batteries in a fire. They may explode. Check with local codes
for special disposal instructions.
iv
Download from Www.Somanuals.com. All Manuals Search And Download.
FCC regulations require that the following information be provided in this manual:
1. This equipment complies with Part 68 of FCC rules. On the bottom of the equip-
ment housing is a label showing the FCC registration number and ringer equiva-
lence number (REN) for this equipment. If requested, provide this information to
the telephone company.
2. If this equipment causes harm to the telephone network, the telephone company
may temporarily discontinue service. If possible, advance notification is given;
otherwise, notification is given as soon as possible. The telephone company will
advise the customer of the right to file a complaint with the FCC.
3. The telephone company may make changes in its facilities, equipment, opera-
tions, or procedures that could affect the proper operation of this equipment.
Advance notification and the opportunity to maintain uninterrupted service are
given.
4. If experiencing difficulty with this equipment, please contact ADTRAN for repair
and warranty information. The telephone company may require this equipment
to be disconnected from the network until the problem is corrected or it is certain
the equipment is not malfunctioning.
5. This unit contains no user-serviceable parts.
6. An FCC compliant telephone cord with a modular plug is provided with this
equipment. This equipment is designed to be connected to the telephone network
or premises wiring using an FCC compatible modular jack, which is Part 68 com-
pliant.
7. The following information may be required when applying to the local telephone
company for a dial-up line for the V.34 modem:
Service Type
REN
FIC
USOC
Loop Start (V.34)
0.8B/ 0.4A
02LS2
RJ-11C
8. The REN is useful in determining the quantity of devices you may connect to
your telephone line and still have all of those devices ring when your number is
called. In most areas, the sum of the RENs of all devices should not exceed five.
To be certain of the number of devices you may connect to your line as deter-
mined by the REN, call your telephone company to determine the maximum REN
for your calling area.
9. This equipment may not be used on coin service provided by the telephone com-
pany. Connection to party lines is subject to state tariffs. Contact your state pub-
lic utility commission or corporation commission for information.
v
Download from Www.Somanuals.com. All Manuals Search And Download.
YEAR 2000 COMPLIANCE
All ADTRAN transmission hardware and software products have been tested and
found to be fully compliant with the YEAR 2000 requirements. This is true for all
models and revisions regardless of the date of manufacture or delivery.
Users who wish to independently verify that specific products are in compliance may
contact ADTRAN Technical Support at 1-888-423-8726.
vi
Download from Www.Somanuals.com. All Manuals Search And Download.
FEDERAL COMMUNICATIONS COMMISSION
RADIO FREQUENCY INTERFERENCE STATEMENT
This equipment has been tested and found to comply with the limits for a Class A dig-
ital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the equipment is operated in
a commercial environment. This equipment generates, uses, and can radiate radio fre-
quency energy and, if not installed and used in accordance with the instruction man-
ual, may cause harmful interference to radio frequencies. Operation of this equipment
in a residential area is likely to cause harmful interference in which case the user will
be required to correct the interference at his own expense.
Shielded cables must be used with this unit to ensure compliance with Class A FCC
limits.
Changes or modifications to this unit not expressly approved by the par-
ty responsible for compliance could void the user' s authority to operate
the equipment.
CANADIAN EMISSIONS REQUIREMENTS
This digital apparatus does not exceed the Class A limits for radio noise emissions
from digital apparatus as set out in the interference-causing equipment standard enti-
tled “Digital Apparatus,” ICES-003 of the Department of Communications.
Cet appareil nuerique respecte les limites de bruits radioelectriques applicables aux
appareils numeriques de Class A prescrites dans la norme sur le materiel brouilleur:
“Appareils Numeriques,” NMB-003 edictee par le ministre des Communications.
vii
Download from Www.Somanuals.com. All Manuals Search And Download.
CANADIAN EQUIPMENT LIMITATIONS
Notice: The Canadian Industry and Science Canada label identifies certified equip-
ment. This certification means that the equipment meets certain telecommunications
network protective, operational, and safety requirements. The Department does not
guarantee the equipment will operate to the user ’s satisfaction.
Before installing this equipment, users should ensure that it is permissible to be con-
nected to the facilities of the local telecommunications company. The equipment must
also be installed using an acceptable methods of connection. In some cases, the com-
pany’s inside wiring associated with a single line individual service may be extended
by means of a certified connector assembly (telephone extension cord). The customer
should be aware that compliance with the above limitations may not prevent degra-
dation of service in some situations.
Repairs to certified equipment should be made by an authorized Canadian mainte-
nance facility designated by the supplier. Any repairs or alterations made by the user
to this equipment, or equipment malfunctions, may give the telecommunications
company cause to request the user to disconnect the equipment.
Users should ensure for their own protection that the electrical ground connections of
the power utility, telephone lines and internal metallic water pipe system, if present,
are connected together. This precaution may be particularly important in rural areas.
Users should not attempt to make such connections themselves, but should
contract the appropriate electric inspection authority, or an electrician, as
appropriate.
The Load Number (LN) assigned to each terminal device denotes the percentage of
the total load to be connected to a telephone loop which is used by the device, to pre-
vent overloading. The termination on a loop may consist of any combination of
devices subject only to the requirement that the total of the Load Numbers of all
devices does not exceed 100.
viii
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 1. Introduction ..................................................................................................... 1-1
Product Overview ............................................................................................................... 1-1
T3 Overview ......................................................................................................................... 1-2
SNMP .................................................................................................................................... 1-2
TELNET ................................................................................................................................ 1-3
Interface Option Cards ....................................................................................................... 1-4
HSSI Card ...................................................................................................................... 1-4
V.35 Card ....................................................................................................................... 1-4
Warranty and Customer Service ....................................................................................... 1-5
Chapter 2. Installation and Operation ........................................................................... 2-1
Unpack, Inspect, Power Up ............................................................................................... 2-1
Receiving Inspection.................................................................................................... 2-1
Installing the Unit ................................................................................................................ 2-2
Rackmount Installation ............................................................................................... 2-2
Desktop Installation..................................................................................................... 2-3
Rear Panel ............................................................................................................................. 2-3
DTE Port Interface Card Slots .................................................................................... 2-4
Alarm Connector.......................................................................................................... 2-4
DTE Port 1 (HSSI Interface)........................................................................................ 2-5
Auxiliary Port ............................................................................................................... 2-5
LAN Port ....................................................................................................................... 2-6
DS3 Interface................................................................................................................. 2-6
Front Panel ........................................................................................................................... 2-6
Control Port .................................................................................................................. 2-6
LED Descriptions ......................................................................................................... 2-9
Chapter 3. Configuration .................................................................................................. 3-1
DS3 Network ........................................................................................................................ 3-2
DS3 Framing ................................................................................................................. 3-3
61200217L1-1
T3SU 300 User Manual
ix
Download from Www.Somanuals.com. All Manuals Search And Download.
Table of Contents
DS3 Timing.................................................................................................................... 3-3
DS3 Scrambler............................................................................................................... 3-4
Data Link ....................................................................................................................... 3-4
Remote Auto-Configuration ....................................................................................... 3-4
DTE Ports ..............................................................................................................................3-4
Port Selections 1-4 ........................................................................................................ 3-5
System Management .........................................................................................................3-11
IP Security ................................................................................................................... 3-13
IP Hosts........................................................................................................................ 3-13
Management Port....................................................................................................... 3-13
Auxiliary Port Mode .................................................................................................. 3-13
Auxiliary Port Baud Rate .......................................................................................... 3-14
Trap IP Addresses ...................................................................................................... 3-15
Unit ID ......................................................................................................................... 3-19
Terminal Timeout....................................................................................................... 3-19
Date/ Time................................................................................................................... 3-19
Dialup Options ........................................................................................................... 3-19
Utilities ................................................................................................................................3-22
Save Configuration ............................................................................................................3-24
Network Port ........................................................................................................................4-2
DS3 Framing ................................................................................................................. 4-2
Network State ............................................................................................................... 4-2
Alarm State.................................................................................................................... 4-2
Data Link State.............................................................................................................. 4-3
Remote State.................................................................................................................. 4-3
DTE Ports ..............................................................................................................................4-5
Interface Type ............................................................................................................... 4-5
x
T3SU 300 User Manual
61200217L1-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Port Status ..................................................................................................................... 4-5
Bandwidth..................................................................................................................... 4-6
DTE Leads ..................................................................................................................... 4-6
Alarm History............................................................................................................... 5-2
Performance Parameters ............................................................................................. 5-4
Chapter 6. Diagnostics ...................................................................................................... 6-1
DTE Ports 1-4................................................................................................................ 6-5
BERT Configuration .................................................................................................... 6-9
Chapter 7. Applications .................................................................................................... 7-1
Single Port Full T3 Bandwidth .......................................................................................... 7-1
Point-to-Point Multiport Application .............................................................................. 7-3
Fractional T3 Carrier Application ..................................................................................... 7-5
Remote SNMP Management Application ....................................................................... 7-7
Appendix A. Pinouts ........................................................................................................ A-1
Appendix B. Specifications Summary ...........................................................................B-1
Appendix C. Acronyms/Abbreviations......................................................................... C-1
Appendix D. Glossary ......................................................................................................D-1
61200217L1-1
T3SU 300 User Manual
xi
Download from Www.Somanuals.com. All Manuals Search And Download.
Table of Contents
xii
T3SU 300 User Manual
61200217L1-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Figure 2-3. Terminal Main Menu...................................................................................... 2-7
Figure 3-1. Configuration Main Menu ............................................................................ 3-2
Figure 3-2. DS3 Network Configuration Menu .............................................................. 3-3
Figure 3-5. Timed Profiles Screen .................................................................................... 3-10
Figure 3-6. Example of a Profile Configuration Menu ..................................................3-11
Figure 3-8. Trap Generation Menu .................................................................................. 3-15
Figure 3-10. Dialup Options Menu ................................................................................. 3-20
Figure 3-11. System Utilities Menu ................................................................................. 3-23
Figure 3-12. T3SU 300 Configuration Menu Tree ......................................................... 3-25
Figure 5-1. Main Local Statistics Menu Screen................................................................ 5-2
Figure 5-2. Current Alarm Count Screen ......................................................................... 5-3
Figure 5-3. 24-Hour Alarm History Screen...................................................................... 5-3
Figure 5-4. Network Statistics Menu for Current 15-Minute Interval......................... 5-5
Figure 5-5. Network Port Statistics 24-Hour History Screen ........................................ 5-6
Figure 5-6. Network Port Statistics Menu (24-Hour Totals).......................................... 5-7
Figure 6-1. Diagnostics Main Menu.................................................................................. 6-2
Figure 6-2. DS3 Diagnostics Menu .................................................................................... 6-3
Figure 6-3. DS3 Payload Loopback Test ........................................................................... 6-4
61200217L1-1
T3SU 300 User Manual
xiii
Download from Www.Somanuals.com. All Manuals Search And Download.
List of Figures
Figure 6-4. Line Loopback Test .......................................................................................... 6-4
Figure 6-5. DTE Port Diagnostics Menu...........................................................................6-5
Figure 6-6. Payload Loopback Test ................................................................................... 6-6
Figure 6-7. Payload BERT Test ........................................................................................... 6-7
Figure 6-8. DTE Loopback Test.......................................................................................... 6-7
Figure 6-9. Payload and DTE Loopback Test................................................................... 6-8
Figure 6-10. BERT Pattern Menu .....................................................................................6-10
Figure 7-1. Single Port Application ................................................................................... 7-2
Figure 7-2. Multiport Application ..................................................................................... 7-3
Figure 7-3. Fractional Application .................................................................................... 7-5
Figure 7-4. Remote Management Application ................................................................7-7
xiv
T3SU 300 User Manual
61200217L1-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 3-1. Near End Alarm Trap Descriptions ............................................................. 3-16
Table 3-2. Far End Alarm Trap Descriptions .............................................................. 3-16
Table 3-4. Network Test Trap Descriptions................................................................... 3-17
Table 4-1. LA and LB Leads............................................................................................... 4-7
Table 7-2. Configuration Example for Multiport Application...................................... 7-4
Table 7-3. Configuration Example for Fractional T3 Application ................................ 7-6
Table 7-4. Configuration Example for Remote Management Application ................. 7-8
Table A-1. Control and Auxiliary Port Pin Assignments............................................. A-1
Table A-2. HSSI Interface Pin Assignments ................................................................... A-2
Table A-3. V.35 Interface Card Pin Assignments .......................................................... A-3
Table A-4. LAN Port Pin Assignments ........................................................................... A-4
61200217L1-1
T3SU 300 User Manual
xv
Download from Www.Somanuals.com. All Manuals Search And Download.
List of Tables
xvi
T3SU 300 User Manual
61200217L1-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 1
Introduction
PRODUCT OVERVIEW
The T3SU 300 is a multiport DSU/ CSU (data service unit/ channel
service unit) that provides access to T3 services. The unit provides a
cost-effective, versatile approach for migrating T1 services to T3.
The TDM (time division multiplexer) multiport design allows you
to share the cost of a T3 line between multiple applications. This
unit maximizes the use of T3 services, providing up to four data
ports capable of transmitting and receiving high-capacity, real time
data.
A HSSI (high speed serial interface) port is built in along with three
slots which accept additional HSSI or V.35 interface cards. The HSSI
interfaces support rates between 75 kbps and 44.2 Mbps in 75 kbps
increments. The high speed V.35 interface option supports rates up
to 10 Mbps in increments of 75 kbps.
Embedded SNMP (simple network management protocol) and
TELNET are available through either a SLIP/ PPP or a 10baseT
ethernet port. Through the Management Information Base II(MIB
II), RFC 1407 standards, and an ADTRAN enterprise MIB, the
T3SU 300 can be configured, monitored, and diagnosed using
standard SNMP network management programs such as Hewlett
Packard’s HP OpenView™, IBM’s Netview™, and Cabletron’s
Spectrum™.
Complete configuration, diagnostics, and performance monitoring
are available through SNMP, TELNET, or a VT 100 terminal
interface. This connection can be made via ethernet, a local EIA-232
61200217L1-1
T3SU 300 User Manual
1-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 1. Introduction
link, or through the built-in V.34 modem (1200217L2 only).
Advanced dial-out on trap capabilities through the built-in modem
allow the T3SU 300 to contact remote hosts and alert them to DSX-3
network conditions (without dedicated management connections).
The T3SU 300 is designed for either desktop use or installation in a
19-inch rack.
The major features or the T3SU 300 are as follows:
•
•
Full feature multiport T3 DSU/ CSU
Maximum of four user data ports (HSSI or high speed V.35)
available
•
•
Automatic or manual remote configuration
Embedded SNMP and TELNET management through 10baseT
ethernet or SLIP/ PPP
•
•
Detailed performance monitoring for local and remote units
Simplified configuration through detailed VT 100 terminal
menu structure
•
•
Optional integrated V.34 modem for dial-up and dial-out
access (product version 1200212L2 only)
Standard 5-year warranty
T3 OVERVIEW
T3 provides the same bandwidth as 28 T1s and is used to
interconnect high-speed bridges, routers, front-end processors, and
data terminal equipment (DTE). T3 service plays a major role in
Internet backbones and public organizations needing broad
bandwidth for WAN (wide area network) connectivity.
SNMP
The T3SU 300's embedded SNMP feature allows the unit to be
accessed and controlled by a network manager through either the
auxiliary (AUX) control port or the 10baseT local area network
1-2
T3SU 300 User Manual
61200217L1-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 1. Introduction
(LAN) port. The T3SU 300 supports the MIB-II standard, RFC 1213,
and the ADTRAN Enterprise Specific MIB.
MIB files are available from ADTRAN in the support section of the
ADTRAN Web page at www.adtran.com.
The term SNMP broadly refers to the message protocols used to
exchange information between the network management system
(NMS) and the managed devices, as well as to the structure of
device management databases. SNMP has three basic components:
Network Manager
Control programs that collect, control, and present data pertinent to
the operation of the network devices. These programs reside on a
network management station.
Agent
Control program that resides in every network device. This
program responds to queries and commands from the network
manager, returns requested information or invokes configuration
changes initiated by the manager, and sends unsolicited traps to the
manager.
MIB
Industry standard presentation of all status and configuration
parameters supported by a network device.
TELNET
TELNET provides a password-protected, remote login facility to
the T3SU 300 that allows a remote user to control the T3SU 300
through the terminal menus. Only one TELNET session may be
active at a time.
61200217L1-1
T3SU 300 User Manual
1-3
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 1. Introduction
INTERFACE OPTION CARDS
Optional interface cards may be purchased to equip the T3SU 300
with up to three additional ports. Both HSSI and V.35 interface
cards are available.
HSSI Card
The optional HSSI card plugs into one of the three card slots on the
rear of the T3SU 300. With optional HSSI cards installed, the total
44.2 Mbps bandwidth of the T3 can be divided among the total
number of ports to provide multiple data channels over the T3. The
total bandwidth of the T3 can be divided among the available ports
The HSSI card can be hot inserted or swapped. When it is inserted
in a slot on the rear panel and its faceplate is secured to the rear
panel of the T3SU 300 with the integral thumb screws, a PCMCIA
type connector on the card mates with a compatible connector on
the main board of the T3SU 300. A standard 50-pin HSSI connector
is then available for DTE connections. See the section DTE Port
Interface Card Slots on page 2-4 for more information on installing
option cards.
V.35 Card
V.35 card is similar to that of the HSSI card except that the
maximum bandwidth of the V.35 card is limited to 10 Mbps.
Like the HSSI card, the V.35 card can be hot inserted or swapped,
and it installs just as the HSSI card does. Instead of the standard
HSSI connector, this card contains a standard 34-pin V.35 connector
for DTE connections. See the section DTE Port Interface Card Slots on
page 2-4 for more information on installing option cards.
1-4
T3SU 300 User Manual
61200217L1-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 1. Introduction
WARRANTY AND CUSTOMER SERVICE
ADTRAN will replace or repair this product within five years from
the date of shipment if it does not meet its published specifications
or fails while in service. For detailed warranty, repair, and return
information refer to the ADTRAN Equipment Warranty and Repair
and Return Policy Procedure.
Return Material Authorization (RMA) is required prior to returning
equipment to ADTRAN.
For service, RMA requests, or further information, contact one of
the numbers listed on the inside back cover of this manual.
61200217L1-1
T3SU 300 User Manual
1-5
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 1. Introduction
1-6
T3SU 300 User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
61200217L1-1
Chapter 2
Installation and Operation
UNPACK, INSPECT, POWER UP
Receiving Inspection
Carefully inspect the T3SU 300 for any damage that may have
occurred in shipment. If damage is suspected, file a claim
immediately with the carrier and contact ADTRAN Technical
Support (see the back cover of this manual). Keep the original
shipping container to use for future shipment or verification of
damage during shipment.
ADTRAN Shipments Include
The following items are included in ADTRAN shipments of the
T3SU 300:
•
•
•
T3SU 300 unit
User manual
An 8-position modular to 8-position modular cable (two of
these cables are included in the 1200217L1 version)
•
•
An 8-position modular to DB-25 female connector
An 8-position modular to DB-25 male connector (1200217L1
version only)
•
A 4-position modular to 4-position modular cable (1200217L2
version only)
•
•
Mounting ears for 19-inch rack installation
Rubber feet for stand-alone use
61200217L1-1
T3SU 300 User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
2-1
Chapter 2. Installation and Operation
The ADTRAN T3SU 300 MIB is available in the support section of the
ADTRAN Web page at www.adtran.com.
Customer Provides
The customer provides an interface cable for each port used. Each
cable should be either HSSI or V.35.
Power Up
Each T3SU 300 unit is provided with a captive eight-foot power
cord, terminated by a three-prong plug which connects to a
grounded 115 VAC power receptacle.
Power to the T3SU 300 must be provided from a grounded 115 VAC,
INSTALLING THE UNIT
The T3SU 300 can be used as a desktop stand-alone device or
mounted into a standard 19-inch equipment rack. See the section
Establishing Terminal Connection on page 2-6 for information on
terminal configuration.
Rackmount Installation
Follow these steps to mount your unit into a rack:
1. Install the 19-inch rackmount flanges on each side of the
T3SU 300 enclosure at one of the three available positions.
Be sure to install the flanges with the screws provided.
2-2
T3SU 300 User Manual
61200217L1-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 2. Installation and Operation
2. After the flanges have been installed, position the T3SU 300 at
the correct location within the rack and secure the mounting
flanges to the mounting rails of the rack.
3. Make all network, DTE, and power connections to the rear of
the unit.
4. Using the 8-position modular to DB-25 female connector and
the 8-position modular to 8-position modular cable, connect a
VT 100 terminal device to the CONTROL interface jack on the
front panel of the unit.
Desktop Installation
Follow these steps when using your T3SU 300 as a desktop unit:
1. Affix the four adhesive-backed rubber feet to the bottom of the
unit, one in each of the four corners. The feet should be placed
approximately one inch from the front or back and one inch
from the sides of the unit
2. Make all network, DTE, and power connections to the rear of
the unit.
3. Using the 8-position modular to DB-25 female connector and
the 8-position modular to 8-position modular cable, connect a
VT 100 terminal device to the CONTROL interface jack on the
front panel of the unit.
REAR PANEL
The T3SU 300 is equipped with three option card slots, a built-in
HSSI interface, an alarm output terminal block, an auxiliary (AUX)
port, a LAN port, and a DS3 interface. Pin assignments for
connectors are given in the appendix Pinouts on page A-1. The
T3SU 300 rear panel is shown in Figure 2-1.
61200217L1-1
T3SU 300 User Manual
2-3
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 2. Installation and Operation
AUX
LAN
ALARM
NC COM NO
DS3 INTERFACE
RX IN
TX OUT
V.35 INTERFACE
DTE PORT 3
HSSI INTERFACE
DTE PORT 2
DTE PORT 4
DTE PORT 1
Item
On/Off Switch
Function
On/off control
115 VAC Connection Power connection
DTE Ports 2-4
Alarm
DTE Port 1
Aux
Interface option card slots
NC/NO relay contacts
Integral HSSI interface
Function depends on product
version (see page 2-5)
10baseT LAN connection
T3 service connection
LAN
DS3 Interface
Figure 2-1. T3SU 300 Rear View
DTE Port Interface Card Slots
The T3SU 300 rear panel has three card slots for the installation of
optional interface cards. To insert cards, perform the following
procedure:
1. Remove blank slot cover from the rear of the T3SU 300.
2. Slide the card into the corresponding rear slot until the card
panel is flush with the T3SU 300 chassis.
3. Push in thumbscrews and turn clockwise to secure the card and
ensure proper connection to the main board of the T3SU 300.
Alarm Connector
The alarm connector is a three-position, screw-type terminal block
that is connected to the three contacts of a Form C-type relay on the
main board of the T3SU 300. This relay is activated any time the
T3SU 300 detects an alarm condition on the T3 network interface.
2-4
T3SU 300 User Manual
61200217L1-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 2. Installation and Operation
ALARM RELAY
The alarm function can be disabled through the
CONFIGURATION
selection of the
menu.
DTE Port 1 (HSSI Interface)
DTE port 1 is a built-in HSSI port that resides on the main board of
the T3SU 300. The bandwidth of this port is configurable from 75
kbps to 44.2 Mbps in 75 kbps increments. When a single application
requires the full 44.2 Mbps of bandwidth, the T3SU 300 does not
have to be equipped with additional port cards.
Auxiliary Port
The auxiliary (AUX) port is an 8-pin modular jack located on the
rear panel of the T3SU 300. The function of this port differs,
depending on which version of the T3SU 300 you have (1200217L1
or 1200217L2).
For the 1200217L1 product, this port provides a DTE-type, EIA-232
asynchronous serial port. This port can be connected to a VT 100
terminal or to a device running SLIP or async PPP. This port can
also connect to an external modem to provide dialup VT 100, SLIP,
SYSTEM
or PPP. This port’s mode and baud rate are selected in the
MANAGEMENT
CONFIGURATION
menu.
portion of the
For the 1200217L2 product, the AUX port provides a telephone line
(POTS) connection for the internal V.34 modem.
For both versions of the product, the T3SU 300 can be configured as
a dial-in host and also as a dial-out-on-TRAP device (meaning that
the unit dials out to a specified host to report error conditions).
Configuration for both the external (L1) and internal (L2) modem
DIALUP OPTIONS
SYSTEM
menu under the
parameters is done in the
MANAGEMENT
CONFIGURATION
menu
portion of the
CONFIGURATION
SYSTEM MANAGEMENT
DIALUP OPTIONS
-> ).
(
->
61200217L1-1
T3SU 300 User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
2-5
Chapter 2. Installation and Operation
LAN Port
The LAN port is an 8-pin modular connector that provides a
10baseT ethernet LAN interface. This LAN interface is used for
SNMP and TELNET control.
DS3 Interface
BNC coaxial cable connections. The receive data from the network
is connected to the RX (In) connector while the transmit data from
the T3SU 300 is connected to the TX (Out) connector.
FRONT PANEL
The T3SU 300 faceplate is shown in Figure 2-2. Descriptions of each
part of the front panel follow.
T3SU 300
IN SERVICE
CONTROL
IN SERVICE
IN TEST
ALARM
LOS
IN SERVICE
IN TEST
ALARM
LOS
IN SERVICE
IN TEST
ALARM
LOS
REMOTE
ACTIVE
IN SERVICE
IN TEST
ALARM
LOS
IN TEST
ALARM
LOS
NETWORK
DTE PORT
1
DTE PORT
2
DTE PORT
3
DTE PORT
4
Figure 2-2. T3SU 300 Front Panel
Control Port
The T3SU 300 has an 8-pin modular jack labeled CONTROL. The
control port provides connection to a VT 100 EIA-232 compatible
interface.
Establishing Terminal Connection
To control the T3SU 300 using a VT 100 terminal, follow this
procedure:
1. Configure the VT 100 terminal for 9600 baud, 8-bit characters,
no parity, and one stop bit (9600, 8N1).
2-6
T3SU 300 User Manual
61200217L1-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 2. Installation and Operation
2. Using the ADTRAN-provided terminal interface cable adapter,
connect the DTE port of a terminal to the 8-pin modular jack
Control
labeled
on the front panel of the T3SU 300.
3. Initialize the terminal session.
4. Press Enter repeatedly until the password prompt appears.
5. Enter the password. The factory default password is adtran.
MAIN
The
menu appears. See Figure 2-3.
6. Make selections by entering the number corresponding to the
chosen parameter. Press ESC to return to the previous screen.
LOGOUT
MAIN
from the
End a terminal session by selecting
menu or by pressing Ctl-C at any time.
Figure 2-3. Terminal Main Menu
Navigating Within the Menus
Navigate within the T3SU 300 terminal menus using the following
procedures:
61200217L1-1
T3SU 300 User Manual
2-7
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 2. Installation and Operation
If you want to...
Press...
select an item
the number corresponding to your
choice, and then press the Enter
key.
scroll between screens
the up and down arrow keys. Addi-
within the same selection tional screens are available when
<up> or <down> is displayed in the
right-hand side of the menu.
return to the previous
menu
the ESC key.
end the terminal session
refresh the display
Ctl-R.
MAIN
The T3SU 300
Status
This selection provides status information on the Network and
Statistics
This selection provides statistical information for the Network port.
See the chapter Statistics on page 5-1 for more information.
Configuration
CONFIGURATION
The
menu is used to set network, DTE, and system
management parameters. See the chapter Configuration on page 3-1
for more detailed information.
Diagnostics
DIAGNOSTICS
The
menu is used to perform loopback and BERT
tests. See the chapter Diagnostics on page 6-1 for more detailed
information.
Remote Login
REMOTE LOGIN
The
selection allows you to configure the remote
T3SU 300. The remote unit’s password is required at login. The
DATALINK
DS3 NETWORK CONFIGURATION
menu)
option (in the
must be enabled in order to perform remote configuration.
2-8
T3SU 300 User Manual
61200217L1-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 2. Installation and Operation
Logout
LOGOUT
The
selection ends the terminal session and logs out of the
system. Password entry is required before a new session can begin.
LED Descriptions
The T3SU 300 has LED status indicators for remote access, the
network port, and for each individual DTE port. These LEDs are
identified as follows:
Remote Active
Network LEDs
This LED is solid when a remote configuration session is taking
place through a TELNET session or from the remote end T3SU 300.
It flashes when the unit is being accessed locally through the front
Control
panel
port.
In Service
This LED is active when a valid signal is being received on the DS3
interface.
In Test
This LED is active when the network interface has been put in
loopback by the service provider.
Alarm
This LED is active when the DS3 receive signal contains framing
errors, the yellow alarm is received from the far end unit, or other
alarm messages are received from the network.
LOS
This LED is active when no receive signal from the network is
detected on the Rx (in) circuit.
DTE Port LEDs
Status
This LED indicates the following conditions:
61200217L1-1
T3SU 300 User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
2-9
Chapter 2. Installation and Operation
LED
Condition
Off
No option card is installed.
Flashing green Interface is available but not configured.
On green
On red
Interface is available and configured.
DTE fault condition (for HSSI interface, no clock
from DTE).
On yellow
For HSSI interface, terminal available (TA) sig-
nal inactive.
In Test
This LED is active when the DTE interface is in a loopback
condition or is performing a BERT test.
TD
This LED is active when the T3SU 300 DTE port is transmitting
data.
RD
This LED is active when the T3SU 300 DTE port is receiving data.
2-10
T3SU 300 User Manual
61200217L1-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 3
Configuration
The T3SU 300 can be configured locally and remotely. Local
configuration is accomplished through a 10baseT ethernet
connection, a SLIP/ PPP port, or a VT 100 terminal. Remote
configuration can take place through the T3 datalink using a local
T3SU 300.
CONFIGURATION
The
menu consists of the following submenus
relating to specific interfaces or functions:
DS3 NETWORK
DTE PORTS
SYSTEM MANAGEMENT
UTILITIES
The Main configuration terminal menu is shown in Figure 3-1. The
complete configuration menu tree is given at the end of this chapter
in Figure 3-12. Detailed descriptions of each individual menu
parameter are given in the following sections. These sections are
DS3 NETWORK
DTE
(page 3-2),
divided by the five submenus:
PORTS
SYSTEM MANAGEMENT
UTILITIES
(page 3-4),
(page 3-11),
SAVE CONFIGURATION
(page 3-22), and
(page 3-24).
61200217L1-1
T3SU 300 User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
3-1
Chapter 3. Configuration
Figure 3-1. Configuration Main Menu
DS3 NETWORK
1 DS3 NETWORK
Select
to access the network configuration
parameters. Configure the T3SU 300 network settings to match the
T3 signal received from the service provider. During remote
DS3 NETWORK
menu is shown in Figure 3-2. Descriptions of the
fields follow the figure.
configuration, this menu is read-only. The
CONFIGURATION
DS3 NETWORK
3-2
T3SU 300 User Manual
61200217L1-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 3. Configuration
Figure 3-2. DS3 Network Configuration Menu
DS3 Framing
Set the framing format to match the format of the receive signal at
the network interface. C-bit parity and M13 framing formats are
supported.
Line Length
DS3 Timing
Set the line length to reflect the physical length of the DS3 network
LONG
SHORT
if the cabling distance exceeds 50 feet; set to
line. Set to
if the distance is less than 50 feet.
LOOP
LOCAL
Set the timing to
network; set to
if the T3SU 300 is to derive timing from the
if the unit is to be the master timing source
for the circuit. In most cases, the unit should be configured for
LOOP
timing.
61200217L1-1
T3SU 300 User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
3-3
Chapter 3. Configuration
DS3 Scrambler
Enable this option to scramble the DS3 payload data. This prevents
certain transport equipment from falsely reporting alarms.
Data Link
ENABLE
Set to
to allow for remote configuration. When enabled, the
T3SU 300 provides a channel between the local and the remote DSU
for point-to-point remote configuration.
Remote Auto-Configuration
MASTER
This feature allows one T3SU 300 (set to
) to automatically
relay its DTE port bandwidth configuration to a second unit (set to
SLAVE
). If desired, the feature can be disabled by either unit.
DTE PORTS
DTE PORTS
The
menu allows you to select a port to configure. If
MASTER CONFIGURATION
(
DS3 NETWORK
REMOTE AUTO CONFIGURATION
MASTER
),
->
->
->
TIMED PROFILES
then a fifth option,
, is available. See Figure 3-3. This
option allows you to set up timed profiles specifying bandwidth
allocation for all four ports.
Configuration selections for the individual ports are described in
TIMED
the following section. A more in-depth description of
PROFILES
is on page 3-10.
3-4
T3SU 300 User Manual
61200217L1-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 3. Configuration
Figure 3-3. DTE Ports Menu
Port Selections 1-4
DTE PORT 1 2 3
4
Select
, , , or to access the following port
configuration parameters. Configure each DTE port to be
PORT
compatible with the DTE equipment attached to it. A
CONFIGURATION
menu example is shown in Figure 3-4. Descriptions
of the individual fields follow the illustration.
61200217L1-1
T3SU 300 User Manual
3-5
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 3. Configuration
Figure 3-4. Port Configuration Menu (with V.35 interface card installed)
Interface Type
This read-only status field shows the interface type of the selected
port (HSSI or V.35).
Port Status
This read-only status field displays one of the following messages
to show the port status of the selected port:
Inactive
PORT
The port is installed, but idle. Activate a port through the
STATE
field of this menu.
Active
The port has been configured and is passing data.
3-6
T3SU 300 User Manual
61200217L1-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 3. Configuration
Waiting
The port has been configured and is waiting for the DTE to issue
the appropriate handshaking signals. For the HSSI interface, the
terminal equipment available (TA) signal must be asserted by the
DTE. For V.35, DTR is required if the TR field in this menu is set to
IDLE WHEN OFF
; otherwise, DTR is ignored.
Error
An error condition such as loss of transmit clock has occurred.
Not Installed
An interface card is not installed in the selected port. If a port is not
PORT CONFIGURATION
installed, the remainder of the
appear.
menu does not
Port State
DISABLED
If a port is installed but not currently in use, set to
. Set to
ENABLED
to activate an installed port.
Nx75k Blocks
This field determines the amount of bandwidth allocated to the
selected port. For a HSSI interface, the selections are from 1-588
(yielding a bandwidth of 75.2 kbps to 44.2 Mbps). For a V.35
interface, the selections are from 1-140 (yielding a bandwidth of
75.2 kbps to 10.5 Mbps). Changes to this field do not take effect
A
PPLY SETTINGS
is selected.
until
Port Bandwidth
This read-only status field shows the amount of bandwidth that
NX75K BLOCKS
will be available if the selection made in the
applied.
field is
Unallocated 75k blocks
This read-only status field shows the number of 75k blocks of
bandwidth not already allocated to the four ports.
Apply Settings
Select this field after making all configuration changes for the
selected port. The changes are then applied to the unit immediately.
61200217L1-1
T3SU 300 User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
3-7
Chapter 3. Configuration
Applying the settings briefly affects all ports of the T3SU 300. You
PORT CONFIGURATION
may cancel changes made to the current
menu by pressing the ESC key.
CS
Selects the control mode for the clear to send (CS) lead. This field
only appears if a V.35 interface card is installed in the selected port.
Forced On
The CS lead remains on and request to send (RS) is ignored as long
as the unit is synchronized and able to pass data.
Follow RS
The CS state matches the RS state.
TR
Selects the T3SU 300’s response to the data terminal ready (TR)
lead. This field only appears if a V.35 interface option card is
installed in the selected port.
Ignored
The T3SU 300 ignores the state of the TR lead.
Idle When Off
The T3SU 300 suspends traffic on the selected port if the TR lead is
off.
SR
Selects the control mode for the data set ready (SR) lead. This field
only appears if a V.35 interface card is installed in the selected port.
Forced On
The SR control lead remains on regardless of the state of the
network.
Off When OOS/OOF
The SR control lead remains on unless the T3SU 300 receives an out
of service/ out of frame (OOS/ OOF) condition from the network.
Off When Test
The SR lead remains on except when the T3SU 300 is executing a
test.
3-8
T3SU 300 User Manual
61200217L1-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 3. Configuration
Off When OOS/OOF or Test
The SR lead remains on except when the unit receives an OOS/
OOF condition from the network or when the unit is executing a
test.
CD
Selects the control mode for the carrier detect (CD) lead. This field
only appears if a V.35 interface card is installed in the selected port.
Forced On
The CD lead remains active at all times.
Off When OOS/OOF
The CD control lead remains on unless the T3SU 300 receives an
OOS/ OOF condition from the network.
Transmit Clock
Selects the source of the clock used to transfer data from the DTE to
the T3SU 300. This selection is only available if a V.35 interface card
is installed in the selected port. Use the following chart to
determine your selection:
Select...
If...
Normal
you want the transmit clock to be derived
from the T3SU 300.
Invert
your DTE device cannot provide a trans-
mit clock signal and data errors are
present between your DTE and the T3SU
300.
External
you are transmitting at high rates. This se-
lection eliminates data errors caused by
excessive delays in the DTE transmit clock
receiver, transmit data driver, and cable
length.
61200217L1-1
T3SU 300 User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
3-9
Chapter 3. Configuration
Selecting Normal or Invert clocking options depends on your DTE, cable
length, and cable characteristics. To verify error free operation, perform a
DTE loopback test and a BERT test from the DTE. See the chapter Diag-
nostics on page 6-1 for information on performing these tests.
Timed Profiles
Using this option, you can allocate bandwidth based on the time of
day. For example, you can assign more bandwidth to the corporate
LAN during business hours and more bandwidth to a backup
machine in the evenings. The T3SU 300 can store two separate user
profiles which have bandwidth selections for each of the four ports.
See Figure 3-5 and Figure 3-6.
Figure 3-5. Timed Profiles Screen
Profiles 1 and 2
The
PROFILE CONFIGURATION
PORT
screens allow you to change the
options for all four ports. See page 3-7
for descriptions of these options. The settings are then assigned to
STATE
NX75K BLOCKS
and
3-10
T3SU 300 User Manual
61200217L1-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 3. Configuration
the selected profile (1 or 2) and apply whenever that profile is
active. See Figure 3-6.
Profile Time (1 and 2)
Enter the time that you want the profile to become active. Enter the
time in military time (i.e., 00:00:00 = 12 AM). The profile remains
active until one of the following occurs: (1) the other profile’s
activation time comes about, or (2) the profile is disabled manually
ACTIVE PROFILE
through the
selection.
Active Profile
Use this field to either manually force a profile to become active
(regardless of the time of day) or to disable the profiles completely.
Figure 3-6. Example of a Profile Configuration Menu
SYSTEM MANAGEMENT
SYSTEM MANAGEMENT
The
menu allows you to configure the T3SU
300 for management through SNMP, TELNET, or a VT 100
interface. Embedded SNMP and TELNET are available through
61200217L1-1
T3SU 300 User Manual
3-11
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 3. Configuration
SYSTEM
either a SLIP/ PPP or a 10baseT ethernet port. The
MANAGEMENT CONFIGURATION
menus are shown in Figure 3-7 and
Figure 3-9. Scroll between the two menus using the up and down
arrows on your keyboard.
Figure 3-7. System Management Configuration Menu (1 of 2)
Local IP Address
Enter the T3SU 300 IP address. This IP address applies to the
ethernet or auxiliary port (when configured for PPP or SLIP). This
address is available from the network administrator.
Subnet Mask
Enter the subnet mask of the T3SU 300. This address is available
from the network administrator.
3-12
T3SU 300 User Manual
61200217L1-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 3. Configuration
Gateway IP Address
Enter the gateway IP address of the T3SU 300. This address is
necessary only if the T3SU 300 and the network manager are
different network, the unit sends it to the gateway.
Remote IP Address
Enter the remote T3SU 300’s IP address to provide network
management access through the local T3SU 300. See the section
Remote SNMP Management Application on page 7-7 for more
information.
IP Security
IP Hosts
Enable or disable the IP Security option. If enabled, the unit accepts
management commands and TELNET sessions from the IP
IP HOSTS
addresses entered into the
fields.
Enter up to 16 IP addresses of management stations from which the
unit should accept management commands. These addresses are
IP SECURITY
only applicable if
is enabled.
Management Port
Assign the management port to be either LAN, FDL (facility
datalink), or the AUX Port.
Auxiliary Port Mode
This selection applies to version 1200217L1 only. Select the AUX
port’s function for your application. The AUX port, located on the
rear panel of the T3SU 300, can communicate through a VT 100
compatible terminal, or a device running SLIP or PPP protocol
(either through a direct connection or dialup through an external
61200217L1-1
T3SU 300 User Manual
3-13
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 3. Configuration
ethernet port is disabled. If you select any of the dialup options, an
DIALUP OPTIONS
additional menu item (
) appears on the second
SYSTEM MANAGEMENT CONFIGURATION
screen. See Figure 3-10. The
DIALUP OPTIONS
are described on page 3-19.
AUXILIARY PORT MODE
Selections for
include local and dialup
MANAGEMENT PORT
options for VT 100, PPP, and SLIP. If
(see page
DIALUP OPTIONS
are available.
AUX PORT
3-13) is set to
, the
Modem Mode
AUX
This selection applies to version 1200217L2 only. Select the
AUX
port function for your application. The
port, located on the
connecting to the internal V.34 modem. The modem interface can
In addition, the T3SU 300 is capable of dial-out operation to report
error conditions. All modem options can be configured in the
DIALUP OPTIONS
CONFIGURATION
SYSTEM MANAGEMENT
menu located on the second
screen. See Figure 3-9. The
DIALUP OPTIONS
are
described on page 3-19.
MODEM MODE
Selections for the
include dialup options for VT 100,
MANAGEMENT PORT
PPP, and SLIP. If the
option (see page 3-13) is
options are available.
AUX PORT
PPP
and
SLIP
set to
, the
Auxiliary Port Baud Rate
AUX
Set the operating speed of the
port to match the connected
device. The selections are 1200, 2400, 4800, 9600, 19200, and
38400 bps.
Read Community Name
Enter the authentication strings used for SNMP management.
Match the T3SU 300 to the SNMP manager for read privileges.
3-14
T3SU 300 User Manual
61200217L1-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 3. Configuration
Write Community Name
Enter the authentication strings used for SNMP management.
Match the T3SU 300 to the SNMP manager for write privileges.
Trap IP Addresses
Enter up to five IP addresses of SNMP managers to which the T3SU
300 sends traps.
Trap Generation
This selection determines which trap types (if any) are generated by
NEAR END ALARM FAR
the unit. Use this menu to enable or disable
,
END ALARM MIB II STANDARD NETWORK TEST
DTE PORT
trap
,
,
, and
types. See Table 3-1 on page 3-16 through Table 3-5 on page 3-18
(following Figure 3-8) for trap descriptions.
Figure 3-8. Trap Generation Menu
61200217L1-1
T3SU 300 User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
3-15
Chapter 3. Configuration
Table 3-1. Near End Alarm Trap Descriptions
Trap Type
If ENABLED, this trap is sent...
Red Alarm
(LOS)
when the unit detects a loss of signal.
Out of Frame
(OOF)
when the unit detects an out of frame condition.
Yellow Alarm
(RAI)
when the unit detects an incoming RAI signal.
when the unit detects an incoming AIS signal.
Blue Alarm
(AIS)
Idle Signal
when the unit detects an incoming idle signal
(1100) over the entire DS3 bandwidth.
Table 3-2. Far End Alarm Trap Descriptions
If ENABLED, this trap is sent...
Trap Type
Red Alarm
(LOS)
when the unit receives indication from the far
end unit through the FEAC channel that the far
end unit has lost its receive signal.
Out of Frame
(OOF)
when the unit receives indication from the far
end unit through the FEAC channel that the far
end unit has lost frame synchronization with the
network.
Yellow Alarm when the unit receives indication from the far
(RAI)
end unit through the FEAC channel that the far
end unit is receiving an RAI indication from the
network.
Blue Alarm
(AIS)
when the unit receives indication from the far
end unit through the FEAC channel that the far
end unit is receiving an AIS indication from the
network.
3-16
T3SU 300 User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
61200217L1-1
Chapter 3. Configuration
Trap Type
If ENABLED, this trap is sent...
Idle Signal
when the unit receives indication from the far
end unit through the FEAC channel that the far
end unit is receiving an idle signal (1100) over
the entire DS3 payload.
Eqpt. Fail
NSA
when the unit receives indication from the net-
work through the FEAC channel of a non-ser-
vice-affecting failure in the network equipment.
Eqpt. Fail SA
when the unit receives indication from the net-
work through the FEAC channel of a service-af-
fecting failure in the network equipment.
Com. Eqpt.
Fail NSA
when the unit receives indication from the net-
work through the FEAC channel of a non-ser-
vice-affecting failure in the network common
equipment.
Table 3-3. MIB II Standard Trap Descriptions
Trap Type
Cold Start
Link Up
If ENABLED, this trap is sent...
when the unit is first powered on.
when the network recovers from a Link Down con-
dition and data transmission is restored.
Link Down
when a network condition prevents data transmis-
sion. This could be either an alarm or a network
test.
Auth. Failure
when an SNMP request is made with the wrong
read or write community names.
Table 3-4. Network Test Trap Descriptions
If ENABLED, this trap is sent...
Trap Type
Network Test In when the unit goes into a DS3 network test, either
commanded locally or remotely.
Network Test
Out
when the unit is in a DS3 network test and the test
is terminated.
61200217L1-1
T3SU 300 User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
3-17
Chapter 3. Configuration
Table 3-5. DTE Port Trap Description
If ENABLED, this trap is sent...
Trap Type
Port Status
Change
when the unit detects a change in any of the four
DTE ports. These traps may be generated when a
DTE interface card is plugged in, a cord is re-
moved, a port is reconfigured, a port goes into an
error condition due to cabling problems, or a port
goes into a test mode.
Toggle All Traps
When activated, this entry allows you to toggle ALL alarms
(previously described) between their disabled and enabled states.
Figure 3-9. System Management Configuration Menu (2 of 2)
Password
Set the password required at login (up to 32 characters). The default
password is adtran.
3-18
T3SU 300 User Manual
61200217L1-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 3. Configuration
Unit ID
Enter a name to identify the unit for management purposes.
Terminal Timeout
Set the amount of time the terminal or TELNET session can remain
inactive before requiring re-entry of the password for access. This
option can be disabled or set for 1 minute, 5 minutes, 15 minutes, 60
minutes, or one day.
Date/Time
Enter date and time information. Enter the time in military time
(separated by colons). Enter the month, date, and year (separated
STATISTICS
by forward slashes). View this information in the
menus.
Alarm Relay
Enable if the alarm terminal block (located on the rear of the unit) is
connected to an audible alarm. If enabled, the alarm circuit is
activated when a network alarm occurs.
Dialup Options
Configure the dialup capabilities of the T3SU 300. For product
version 1200217L1, this option is only available if a dialup selection
AUXILIARY PORT MODE
was made for the
(described on page 3-13).
For product version 1200217L2, this option is always available. See
Figure 3-10. Descriptions of the individual fields of this menu
follow the figure.
61200217L1-1
T3SU 300 User Manual
3-19
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 3. Configuration
Figure 3-10. Dialup Options Menu
Primary and Secondary Phone Numbers
When the T3SU 300 dials out to send a trap, it first dials the
PRIMARY PHONE NUMBER
. If the call is unsuccessful, it tries the
SECONDARY PHONE NUMBER
. Attempts between the two numbers
continue until a call is established and the trap is reported (or until
each number’s maximum for redial attempts is reached).
Initializing String
The AT command entered in this field is used to initialize the
modem. Normally, this field should be left at the default setting
(ATZ).
Dial String
The AT command entered in this field causes the modem to dial
out. Normally, this field should be left at the default setting
(ATDT).
3-20
T3SU 300 User Manual
61200217L1-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 3. Configuration
Maximum Redial Attempts
The T3SU 300 attempts to establish a call the number of times
entered in this field. If a successful call is not established after the
final attempt, the T3SU 300 discards the trap messages.
Idle Timeout
Once a call is established and the trap messages are sent, the
T3SU 300 remains online for the amount of seconds entered in this
field. If the field is set to 0, the unit hangs up as soon as the trap is
sent.
Connection Timeout
The T3SU 300 waits for a connection the amount of seconds entered
in this field. Timing begins as soon as the dial command is issued.
Pause Between Calls
The T3SU 300 waits the number of seconds entered in this field
between redial attempts.
Dialout On Trap
Enable or disable the T3SU 300’s ability to dial out to report traps.
A
UXILIARY PORT MODE
(product version 1200217L1) or
When the
MODEM MODE
DIALUP
(product version 1200217L2) is configured for
VT 100
, the unit reports error conditions in plain ASCII with the
following information:
•
The Unit ID value programmed in the Unit ID field of the
SYSTEM MANAGEMENT
second
screen (see Figure 3-9)
•
A trap code indicating the error condition (selected from the
TRAP GENERATION
SYSTEM MANAGEMENT
screen under
)
•
The date and time when the error was logged
AUXILIARY PORT MODE
MODEM MODE
is configured for
When the
or
DIALUP PPP
DIALUP SLIP
, the unit logs in to the PPP/ SLIP host
or
and reports the error conditions to the hosts designated under the
TRAP IP ADDRESSES
SYSTEM MANAGEMENT
).
(also found under
61200217L1-1
T3SU 300 User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
3-21
Chapter 3. Configuration
Answer on Ring
Enable or disable the T3SU 300’s ability to accept an incoming call.
If enabled, incoming calls are automatically answered by the
T3SU 300, allowing you to remotely perform management
functions.
Hangup
Selecting this option forces the T3SU 300 to end an established call.
Last Modem Response
This status field displays the last modem response to the T3SU 300.
Possible responses include:
OK
CONNECT
BUSY
ERROR
NO DIALTONE
NO CARRIER
UTILITIES
UTILITIES
The
menu allows you to view T3SU 300 system
information (including self test results), revert to default
configuration settings, or flash load a new version of software. The
UPDATE FLASH SOFTWARE
selection is only applicable when
SYSTEM UTILITIES
configuring the unit locally. The
menu is shown
in Figure 3-11. Possible results for the self test are listed in the
following table
3-22
T3SU 300 User Manual
61200217L1-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 3. Configuration
:
If the self test results are...
Then...
PASS
the self test was successful and
the unit is ready to use.
BAD RAM DATA
BAD RAM ADDRESS
BAD CHECKSUM
contact ADTRAN Technical
Support. See the inside back
cover of this manual for more
information.
BAD BOOT SECTOR
DS3F LOOPBACK FAILURE
ARTE TERMINAL LOOPBACK FAILURE
or
ARTE INTERNAL LOOPBACK FAILURE
S
AVE CONFIGURATION
CONFIGURATION CORRUPT
select
CONFIGURATION
from the main
menu. If condition persists,
contact ADTRAN Technical
Support.
Figure 3-11. System Utilities Menu
61200217L1-1
T3SU 300 User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
3-23
Chapter 3. Configuration
SAVE CONFIGURATION
SAVE CONFIGURATION
The
selection commits the current
configuration changes to nonvolatile memory. If this option is not
selected after making changes to the configuration, the unit reverts
to its previous configuration when powered down.
3-24
T3SU 300 User Manual
61200217L1-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 4
Status
1 STATUS
MAIN
from the
View port status information by selecting
menu. Information for the network port and the DTE ports is
STATUS
provided. The
menu is shown in Figure 4-1.
Figure 4-1. Status Menu
61200217L1-1
T3SU 300 User Manual
4-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 4. Status
NETWORK PORT
DS3 Framing
The DS3 framing type is shown in this field.
Network State
This field displays the current condition of the network. Possible
conditions are listed in the following table:
Condition
Normal
Alarm
Description
The T3SU 300 is ready to pass data.
The unit is currently receiving an alarm indication.
RECEIVE ALARM
termine the alarm type.
See the
field in this menu to de-
DIAGNOS
-
In Test
The unit is currently in test mode. The
TICS
menu provides information on test type.
Alarm State
This field displays the current alarm condition of the T3SU 300.
Possible conditions are given in the following table:
:
Condition
Normal
Description
No alarms are currently being received.
Yellow
The unit is transmitting a yellow alarm from the
network. This alarm is a signal sent back toward
the source of a failed transmit circuit. The X-bits
(X1 and X2) are set to zero.
LOS (Red
Alarm)
The unit has lost the Rx signal.
4-2
T3SU 300 User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
61200217L1-1
Chapter 4. Status
Condition
Description
Blue (AIS)
The unit is receiving a blue alarm condition from
the network. A blue alarm occurs when consecu-
tive 1010s are received in the information bits.
This indicates that there is a transmission fault lo-
cated either at or upstream from the transmitting
terminal.
OOF
Idle
The unit detects an out of frame condition from the
network.
The unit detects an idle sequence from the net-
work. Service is immediately available for use.
Data Link State
This field displays the current state of the data link between the
local and the remote T3SU 300s. Possible states are listed in the
following table:
Condition
Description
Normal
The local unit’s data link is in sync with the remote
unit.
DATA LINK
CONFIGURATION
DS3 NETWORK
Disabled
Down
The
option in the
DISABLED
.
menu is set to
The local and remote units are not in sync.
Remote State
This field displays the current state of the remote link. Possible
states are listed in the following table:
61200217L1-1
T3SU 300 User Manual
4-3
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 4. Status
Condition
Description
Normal
No alarms are currently being received.
RAI (Yellow
Alarm)
The unit is transmitting a yellow alarm from the
network. This alarm is a signal sent back toward
the source of a failed transmit circuit. The X-bits
(X1 and X2) are set to zero.
LOS (Red
Alarm)
The unit has lost the Rx signal.
AIS (Blue
Alarm)
The unit is receiving a blue alarm condition from
the network. A blue alarm occurs when consecu-
tive 1010s are received in the information bits.
This indicates that there is a transmission fault lo-
cated either at or upstream from the transmitting
terminal.
OOF
Idle
The unit detects an out of frame condition from the
network.
The unit detects an idle sequence from the net-
work. Service is immediately available for use.
Eqpt Fail (SA) The network has signaled a service affecting
equipment failure condition.
Eqpt Fail
(NSA)
The network has signaled a non-service affecting
equipment failure condition.
ComEqptFail The network has signaled a non-service affecting
(NSA)
common equipment failure condition.
Unknown
The T3SU 300 is unable to determine the state of
the network or the remote unit.
4-4
T3SU 300 User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
61200217L1-1
Chapter 4. Status
DTE PORTS
The following status information is available for DTE Ports 1-4.
Interface Type
The interface type of the port is shown in this field (HSSI or V.35).
Port Status
This field displays the current port status. Possible states are listed
in the following table:
Condition
Description
Inactive
The port is installed, but idle. Activate a port
PORT STATE
DTE PORT
field of the
through the
CONFIGURATION
menu.
Active
Error
The port has been configured and is passing
data.
An error condition such as loss of transmit clock
has occurred.
In Test
The unit is currently in test mode.
Waiting for
DTE
The port has been configured and is waiting for
the DTE to issue the appropriate handshaking sig-
nals. For the HSSI interface, the terminal equip-
ment available (TA) signal must be asserted by
the DTE. For V.35, DTR is required if the TR field
IDLE WHEN OFF
is set to
; otherwise, DTR is ig-
DTE PORT
nored. The TR field is found in the
CONFIGURATION
menu.
61200217L1-1
T3SU 300 User Manual
4-5
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 4. Status
Bandwidth
Displays the amount of bandwidth currently being used by the
port.
DTE Leads
If a lead is active on the port, it is displayed in this field. The leads
differ according to the interface type. Lead descriptions for both the
HSSI and the V.35 interfaces follow.
:
HSSI Interface
Condition
Leads
TA (terminal available)
ness to transmit data.
CA (communications
equipment available)
Asserted by the T3SU 300 to indicate
readiness to transmit data.
LA (loopback circuit A) The condition reflected by this lead is
dependent upon the LB lead. See Table
4-1 on page 4-7.
LB (loopback circuit B)
The condition reflected by this lead is
dependent upon the LA lead. See Table
4-1 on page 4-7.
LC (loopback circuit C) Asserted by the unit to request a loop-
back from the DTE.
TM (test mode)
Asserted by the T3SU 300 when either
the network or the port is being tested.
Both TA and CA must be on before data will flow.
4-6
T3SU 300 User Manual
61200217L1-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 4. Status
Table 4-1. LA and LB Leads
LB Condition
LA
Off
On
Off
On
Off
Off
On
On
No test (normal)
Local line loopback
Remote line loopback
Local DTE loopback
V.35 Interface Leads
RS:
CS:
CD:
TR:
SR:
LL:
RL:
TM:
Request to send
Clear to send
Carrier detect
Data terminal ready
Data set ready
Local DTE port loopback
Remote port payload loopback
Test mode. Asserted by the T3SU 300 when either the
network or the port is being tested.
61200217L1-1
T3SU 300 User Manual
4-7
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 4. Status
4-8
T3SU 300 User Manual
61200217L1-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 5
Statistics
VIEWING STATISTICAL INFORMATION
2 STATISTICS
MAIN
STATISTICS
menu to access
Select
from the
menus. Alarm information and performance parameters are
available for both the near and far ends of the network. Statistical
information is given in screens based on the following time
periods: the current 15-minute interval, a 24-hour history (divided
into 96 15-minute intervals), and the totals for the previous 24
hours. Also, a cumulative alarm count is given. This count
continues indefinitely until reset by the user. See Figure 5-1 for the
LOCAL STATISTICS
main
screen.
If the Datalink option is disabled, remote statistics are not available
CONFIGURATION
DS3 NETWORK
DATA LINK
-> ).
(
->
61200217L1-1
T3SU 300 User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
5-1
Chapter 5. Statistics
Figure 5-1. Main Local Statistics Menu Screen
Alarm History
The T3SU 300 keeps track of yellow, blue, and red alarms for the
near end. View alarm history information in one of the three time
period selections, or view a cumulative alarm count. Information in
these fields is for the given time period (if any) since the last reset.
CLEAR ALL
The cumulative alarm count continues indefinitely until
LOCAL STATISTICS
is selected. See Figure 5-2 and Figure 5-3 for
examples of alarm history screens.
The count given reflects the number of times the alarm has occurred (rath-
er than the number of seconds the alarm was active).
5-2
T3SU 300 User Manual
61200217L1-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 5. Statistics
Performance Parameters
View performance parameter information in one of the three time
period selections. Information in these fields is for the given time
period since the last reset. When viewing the 24-hour history
statistics screen, use the left and right arrow keys to scroll through
all 96 15-minute intervals. See Figure 5-4 through Figure 5-6 for
Descriptions of each field of these screens follow:
Interval starting at:
Time that the 15-minute interval began. This field is only displayed
in the 24-hour history screen which gives information for the
previous 24 hours divided into 15-minute intervals (shown in
Figure 5-3).
Unavailable Seconds (UAS)
Time in seconds that the network port is unavailable for data
delivery. This means that the T3 link is down or in test, or that the
signaling state is down.
Severely Errored Framing Seconds (SEFS)
Number of seconds with one or more out of frame defects or a
detected incoming AIS.
Line Coding Violations (LCV)
Number of BPVs (bipolar violations) and EXZs (excessive zeros)
that have occurred.
Line Errored Seconds (LES)
Number of seconds in which one or more CVs or one or more LOS
(loss of signal) defects occurred.
5-4
T3SU 300 User Manual
61200217L1-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 5. Statistics
Figure 5-4. Network Statistics Menu for Current 15-Minute Interval
P-Bit Errored Seconds (PES)
Number of seconds with one or more PCVs (P-bit coding
violations), one or more out of frame defects, or a detected
incoming AIS (alarm indication signal). This count is not
incremented when UASs (unavailable seconds) are counted.
P-Bit Severely Errored Seconds (PSES)
Number of seconds with 44 or more PCVs, one or more out of
frame defects, or a detected incoming AIS. This count is not
incremented when UASs are counted.
P-Bit Coding Violations (PCV)
Number of coding violation (CV) error events that have occurred.
C-Bit Coding Violations (CCV)
In C-bit parity mode, this is a count of coding violations reported
via the C-bits or the number of C-bit parity errors that have
occurred.
61200217L1-1
T3SU 300 User Manual
5-5
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 5. Statistics
Figure 5-5. Network Port Statistics 24-Hour History Screen
C-Bit Errored Seconds (CES)
Number of seconds with one or more CCVs, one or more out of
frame defects, or a detected incoming AIS. This count is not
incremented when UASs are counted.
C-Bit Severely Errored Seconds (CSES)
Number of seconds with 44 or more CCVs, one or more out of
frame defects, or a detected incoming AIS. This count is not
incremented when UASs are counted.
F-Bit Errors (FBE)
Number of times an F-bit framing error has occurred.
M-Bit Errors (MBE)
Number of times an M-bit framing error has occurred.
5-6
T3SU 300 User Manual
61200217L1-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 5. Statistics
Figure 5-6. Network Port Statistics Menu (24-Hour Totals)
Clear All Local Statistics/Refresh All Remote Statistics
Clears or refreshes all current information. These selections affect
all statistical information (not just the displayed screen).
61200217L1-1
T3SU 300 User Manual
5-7
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 5. Statistics
5-8
T3SU 300 User Manual
61200217L1-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 6
Diagnostics
DIAGNOSTICS
The
menu allows you to initiate loopback and BERT
DIAGNOSTICS
tests from the T3SU 300. Figure 6-1 shows the main
menu. Tests can be performed for the entire DS3 or for an
individual DTE port. To choose a port from the left column of the
menu, select the port’s corresponding number and press Enter .
The individual port menus provide loopback and BERT selections.
BERT configuration options and results are given in the right
DIAGNOSTICS
column of the main
menu. Diagnostic selections are
described in the following sections.
You can only perform a BERT test on one port at a time. If a BERT test is
already in progress and a second BERT test is selected for another port,
the first test is discontinued.
Loopback tests may be performed simultaneously on all ports.
61200217L1-1
T3SU 300 User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
6-1
Chapter 6. Diagnostics
Figure 6-2. DS3 Diagnostics Menu
Data Mode
Ends a test already in progress for this port.
DS3 Payload Loopback
During this test, all payload information is re-framed and looped
back towards the network. See Figure 6-3 for a block diagram
illustrating the loopback point and the signal paths for this test.
This test does not interrupt data flow from the network to the DTE, but
it does block all DTE-to-network data.
61200217L1-1
T3SU 300 User Manual
6-3
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 6. Diagnostics
T3SU 300
DTE
Figure 6-3. DS3 Payload Loopback Test
Line Loopback
This test allows the loop interface (LINE) section of the local
T3SU 300 to be tested from the remote T3SU 300 over the actual T3
circuit. Testing from the remote end of the circuit is performed by
using a 511 test pattern or DTE data generated by the remote host.
With this test, the T3SU 300 transceiver receives data from the
network and loops it back toward the network through its
transmitter. The transmitted data is identical to the receive data
(including framing errors) and can therefore be accurately tested by
the carrier for errors. See Figure 6-4.
The Line Loopback test is only available in loop timed mode
(CONFIGURATION -> DS3 NETWORK -> DS3 TIMING -> LOOP).
T3SU 300
DTE
Figure 6-4. Line Loopback Test
6-4
T3SU 300 User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
61200217L1-1
Chapter 6. Diagnostics
BERT
Select BERT to perform a bit error rate test over the entire payload
bandwidth. Only one BERT test may be performed at a time.
Remote DS3 Loopback
This selection initiates a DS3 Loopback test for the remote unit. DS3
Loopback tests are described previously on page 6-3.
Remote Loopback with BERT
This selection initiates a DS3 Loopback test for the remote unit and
bandwidth.
DTE Ports 1-4
Access the DTE port diagnostic options by selecting the number
corresponding with the desired port (2 through 5) from the main
DIAGNOSTICS
menu. The menu in Figure 6-5 appears.
Figure 6-5. DTE Port Diagnostics Menu
61200217L1-1
T3SU 300 User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
6-5
Chapter 6. Diagnostics
Data Mode
Ends a test already in progress.
Payload Loopback
This selection initiates a Payload Loopback test for all data on the
selected port rather than for the entire DS3. During this test, the
data is looped back in the network direction. Perform this test to
verify the integrity of the portion of the DS3 link connecting the
selected port of the T3SU 300 and the remote DTE. This test is non-
intrusive to the three other ports. See Figure 6-6.
This test does not interrupt data flow from the network to the DTE, but it
does block all DTE-to-network data for the selected port.
T3SU 300
MU
DTE
Figure 6-6. Payload Loopback Test
Payload BERT
This selection performs a bit error rate test on the selected port.
This test in non-intrusive to the other three ports. Only one BERT
test may be performed at a time. This test is normally performed
from the remote and local ends simultaneously to determine
whether the errors are coming from the transmit or the receive
direction. See Figure 6-7.
6-6
T3SU 300 User Manual
61200217L1-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 6. Diagnostics
T3SU 300
BERT OUT
MU
DTE
BERT IN
DTE Loopback
This test is used to verify proper operation of the link between the
T3SU 300 and the terminal equipment. During this test, all data
sent by the terminal equipment is looped back to the terminal
equipment. A block diagram illustrating the loopback point and the
signal path is shown in Figure 6-8.
While in DTE Loopback, data from the host is transmitted into the
network.
T3SU 300
MU
DTE
Figure 6-8. DTE Loopback Test
61200217L1-1
T3SU 300 User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
6-7
Chapter 6. Diagnostics
Payload and DTE Loopback
Select this test to perform payload and DTE loopbacks
simultaneously. The individual tests are described previously on
page 6-3 and page 6-7. See Figure 6-9 for a block diagram
illustrating this test.
T3SU 300
MU
DTE
Figure 6-9. Payload and DTE Loopback Test
Remote Port Payload Loopback
This selection initiates a Payload Loopback on the remote T3SU 300
for all data on the selected port. Perform this test to verify the
integrity of the portion of the DS3 link connecting the local DTE
and the selected port of the remote T3SU 300. All other ports on
both the local and remote units are unaffected.
Remote Payload Loopback with BERT
Perform this test to verify the integrity of the link between the
selected port of the local T3SU 300 and the corresponding remote
T3SU 300 port. During this test, the remote unit loops back all data
for the selected port, while the local unit sends and checks the
selected BERT pattern. The loopback point and the signal paths for
the remote T3SU 300 are the same as the Payload Loopback test for
the local T3SU 300 (shown in Figure 6-6).
6-8
T3SU 300 User Manual
61200217L1-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 6. Diagnostics
BERT Configuration
The following options apply to any of the tests involving BERT
testing.
Pattern
Select the desired test pattern for the BERT test (see Figure 6-10).
The internal test pattern generator can be configured for the
following types of test patterns:
•
•
•
•
All Zeros
All ones
2^15-1
2^23-1
The test pattern is used to independently test the operation of the
framing circuitry and the network interface of the T3SU 300.
Instead of using data from the host, this test uses data generated by
the T3SU 300’s internal test pattern generator and detector.
61200217L1-1
T3SU 300 User Manual
6-9
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 6. Diagnostics
Figure 6-10. BERT Pattern Menu
Invert Pattern
ENABLE
If set to
BERT test pattern. This allows the unit to be compatible with test
equipment which generates inverted BERT patterns.
BERT Information Fields
The following five fields provide information about the most
recently issued BERT test. These fields appear in the main
DIAGNOSTICS
menu (shown in Figure 6-1).
Port
Displays which port is transmitting and receiving the BERT
pattern.
Direction
Displays the direction in which the BERT pattern is being sent.
State
SYNC
NO SYNC
to indicate whether or not the
Displays either
or
unit is in sync with the BERT pattern.
6-10
T3SU 300 User Manual
61200217L1-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 6. Diagnostics
Errors
Displays the number of BERT errors received by the T3SU 300 since
the last reset.
Current Err/Sec
Displays the number of BERT errors received by the unit in the last
second.
Insert Error
Clear Errors
Inserts one error into the data stream.
Clears the error counts given in the BERT information fields of this
menu.
Reset All Tests
Discontinues all active tests and clears the counts displayed in the
BERT information fields.
61200217L1-1
T3SU 300 User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
6-11
Chapter 6. Diagnostics
6-12
T3SU 300 User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
61200217L1-1
Chapter 7
Applications
This chapter provides examples of some common T3 applications.
The examples include a single port DSU/ CSU full T3 bandwidth
application, a point-to-point multiport application (page 7-3), a
fractional T3 application (page 7-5), and a remote SNMP
management application (page 7-7). The configuration selections
given in these examples may need modification based on your
network configuration.
SINGLE PORT FULL T3 BANDWIDTH
In applications requiring full T3 bandwidth, the T3SU 300 operates
with other vendor products that support 44.2 Mbps data over
unchannelized T3 circuits.
In the application shown in Figure 7-1, the T3SU 300 provides
network connectivity for a router running at 44.2 Mbps. The data is
frame relay and the unit is SNMP-managed via the local ethernet.
See Table 7-1 for an example configuration.
61200217L1-1
T3SU 300 User Manual
7-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 7. Applications
Router
T3
Dedicated
or Packet
Network
HSSI
44.2 Mbps
T3SU 300
CONTROL
IN SERVICE
IN TEST
ALARM
LOS
REMOTE
ACTIVE
IN SERVICE
IN TEST
ALARM
LOS
IN SERVICE
IN TEST
ALARM
LOS
IN SER
VICE
IN SERVICE
IN TEST
ALARM
LOS
IN TEST
ALARM
LOS
NETWORK
DTE PORT
1
DTE PORT
2
DTE PORT
3
DTE PORT
4
T3SU 300
Figure 7-1. Single Port Application
Table 7-1. Configuration Example for Single Port Full T3
Bandwidth Application
Local T3SU 300
Network
DTE 1
DS3 Framing - C-bit Parity
Line Length - Short
DS3 Timing - Loop
Datalink - Enabled
Port State - Enabled
Nx75k blocks - 588
Port State - Disabled
Port State - Disabled
Port State - Disabled
Local IP Address - 10.4.10.2
DTE 2
DTE 3
DTE 4
System
Management
Subnet Mask -
255.255.255.0
Gateway IP Address -
10.4.10.1
IP Security - Disabled
Trap IP Address - 10.4.10.10
Management Port - LAN
7-2
T3SU 300 User Manual
61200217L1-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 7. Applications
point-to-point T3 circuit, additional data ports can be installed into
the T3SU 300 for multiport operation. The T3SU 300 supports up to
three port option cards (either high-speed V.35 or HSSI). These
option cards are hot swappable and can be field installed. See the
section DTE Port Interface Card Slots on page 2-4 for more
information on card installation.
This application (shown in Figure 7-2) supports two subnet
connection, and a main frame data connection. The T3SU 300
supports the high speed data connection requirements of the
routers (using the HSSI ports), as well as the V.35 data connection
requirements of the video conferencing unit and the main frame.
The bandwidth is split by the T3SU 300 to provide 18 Mbps for each
router, 1.5 Mbps for the video conference units, and 6 Mbps for the
main frames. See Table 7-2 for an example configuration of this
application.
Main
Frame
Main
Frame
Video
Conferencing
V.35
6 Mbps
V.35
6 Mbps
Video
Conferencing
V.35
V.35
1.5 Mbps
1.5 Mbps
Router
Router
T3
T3
Dedicated
Network
HSSI
18 Mbps
HSSI
T3SU 300
T3SU 300
CONTROL
CONTROL
REMOTE
ACTIVE
IN SERVICE
IN TEST
ALARM
LOS
IN SERVICE
IN TEST
ALARM
LOS
REMOTE
ACTIVE
IN SERVICE
IN SERVICE
IN SERVICE
IN SERVICE
IN TEST
ALARM
LOS
IN SERVICE
IN TEST
ALARM
LOS
IN SERVICE
IN TEST
ALARM
LOS
IN SERVICE
IN TEST
ALARM
LOS
IN SERVICE
IN TEST
ALARM
LOS
IN TEST
ALARM
LOS
IN TEST
IN TEST
ALARM
LOS
ALARM
LOS
NETWORK
NETWORK
DTE PORT
1
DTE PORT
1
DTE PORT
2
DTE PORT
2
DTE PORT
3
DTE PORT
3
DTE PORT
4
DTE PORT
4
18 Mbps
Router
T3SU 300
T3SU 300
Router
HSSI
18 Mbps
HSSI
18 Mbps
Figure 7-2. Multiport Application
61200217L1-1
T3SU 300 User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
7-3
Chapter 7. Applications
Table 7-2. Configuration Example for Multiport
Application
Local T3SU 300
Remote T3SU 300
Network
DS3 Framing - C-bit Parity
Line Length - Short
DS3 Framing - C-bit Parity
Line Length - Short
DS3 Timing - Loop
Datalink - Enabled
Port State - Enabled
Nx75k blocks - 240
Port State - Enabled
Nx75k blocks - 240
DS3 Timing - Loop
Datalink - Enabled
Port State - Enabled
Nx75k blocks - 240
Port State - Enabled
Nx75k blocks - 240
DTE 1 (HSSI)
DTE 2 (HSSI)
DTE 3 (V.35)
DTE 4 (V.35)
Port State - Enabled
Nx75k blocks - 80
Port State - Enabled
Nx75k blocks - 80
Port State - Enabled
Nx75k blocks - 20
Port State - Enabled
Nx75k blocks - 20
System
Local IP Address - 10.4.10.2
Management
Subnet Mask -
Nothing required. Remote unit
can be managed using the lo-
cal T3SU 300.
255.255.255.0
Gateway IP Address -
10.4.10.1
IP Security - Disabled
Trap IP Address - 10.4.10.10
Management Port - LAN
7-4
T3SU 300 User Manual
61200217L1-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 7. Applications
FRACTIONAL T3 CARRIER APPLICATION
When network providers want to provide service at rates less than
full T3, T3SU 300 units can be used in pairs for deploying sub-T3
rate services.
In this application example (shown in Figure 7-3), a carrier provides
fractional T3 access at 8 Mbps for internet connectivity. The data
connection can be either V.35 or HSSI at either location. This
network uses a HSSI port at the carrier’s internet POP (point of
presence) and a high-speed V.35 connection at the customer ’s
router. The carrier manages both the local and remote T3SU 300s
via SNMP. Table 7-3 gives an example configuration for this
application.
While in DTE Loopback, data from the host is transmitted into the net-
work.
Router
Router
Carrier
Internet
Access
HSSI
8 Mbps
V.35
8 Mbps
T3
T3
Dedicated
Network
T3SU 300
T3SU 300
CONTROL
CONTROL
REMOTE
ACTIVE
IN SERVICE
IN TEST
ALARM
LOS
IN SERVICE
IN TEST
ALARM
LOS
REMOTE
ACTIVE
IN SERVICE
IN TEST
ALARM
LOS
IN SERVICE
IN TEST
ALARM
LOS
IN SERVICE
IN TEST
ALARM
LOS
IN SERVICE
IN SER
VICE
IN SERVICE
IN TEST
ALARM
LOS
IN SERVICE
IN TEST
ALARM
LOS
IN SERVICE
IN TEST
ALARM
LOS
IN TEST
ALARM
LOS
IN TEST
ALARM
LOS
NETWORK
NETWORK
DTE PORT
1
DTE PORT
1
DTE PORT
2
DTE PORT
2
DTE PORT
3
DTE PORT
3
DTE PORT
4
DTE PORT
4
T3SU 300
T3SU 300
Figure 7-3. Fractional Application
61200217L1-1
T3SU 300 User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
7-5
Chapter 7. Applications
Table 7-3. Configuration Example for Fractional T3
Application
Local T3SU 300
Remote T3SU 300
Network
DS3 Framing - C-bit Parity
Line Length - Short
DS3 Framing - C-bit Parity
Line Length - Short
DS3 Timing - Loop
Datalink - Enabled
Port State - Disabled
Port State - Enabled
Nx75k blocks-107
DS3 Timing - Loop
Datalink - Enabled
Port State - Disabled
Port State - Enabled
Nx75k blocks-107
DTE 1
DTE 2
HSSI (Local)
V.35 (Remote)
DTE 3
Port State - Disabled
Port State - Disabled
Port State - Disabled
Port State - Disabled
DTE 4
System
Local IP Address - 12.6.12.2
Management
Subnet Mask -
255.255.255.0
Nothing required. Remote unit
can be managed using the lo-
cal T3SU 300.
Gateway IP Address -
12.6.12.1
IP Security - Disabled
Trap IP Address - 12.6.12.10
Management Port - LAN
7-6
T3SU 300 User Manual
61200217L1-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 7. Applications
REMOTE SNMP MANAGEMENT APPLICATION
A remote T3SU 300 can be managed by a local management station
if the remote unit is assigned its own IP address. This address must
DATALINK
option must be enabled on both units.
In this application example (shown in Figure 7-4) a local T3SU 300,
connected to the same LAN as the management station, provides
management access to a remote T3SU 300. The local unit has the
REMOTE IP ADDRESS
remote unit’s IP address in its
IP address is entered into the remote unit’s
field. Table 7-4 gives an example configuration for this application.
field. That same
LOCAL IP ADDRESS
IP =10.4.10.2
IP =10.4.10.3
T3
T3SU 300
IN ERVICE
T3SU 300
IN ERVICE
CONTROL
IN
IN TES
ALARM
LO
S
ERVICE
CONTROL
I
N
S
E
R
V
I
C
E
IN
IN TES
ALARM
LO
S
ERVICE
I
N
S
E
R
V
I
C
E
IN
IN TES
ALARM
LO
S
ERVICE
I
N
S
E
R
V
I
C
E
REMOTE
ACTIVE
IN
S
ERVICE
S
REMOTE
ACTIVE
IN
S
ERVICE
S
T
I
N
T
E
S
T
T
I
N
T
E
S
T
T
I
N
T
E
S
T
I
N
T
E
S
T
I
N
T
E
S
T
I
N
T
E
S
T
I
N
T
E
S
T
ALARM
LOS
ALARM
LOS
DTE PORT
ALARM
LOS
DTE PORT
ALARM
LOS
ALARM
LOS
ALARM
LOS
ALARM
LOS
S
S
S
NETWORK
NETWORK
DTE PORT
1
1
DTE PORT
2
2
DTE PORT
3
DTE PORT
3
DTE PORT
4
DTE PORT
4
T3SU 300
T3SU 300
IP =10.4.10.3
Figure 7-4. Remote Management Application
61200217L1-1
T3SU 300 User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
7-7
Chapter 7. Applications
Table 7-4. Configuration Example for Remote
Management Application
Local T3SU 300
Datalink = Enabled
Local IP Address= 10.4.10.2
Remote T3SU 300
Network
System
Datalink = Enabled
Local IP Address= 10.4.10.3
Management
Subnet
Mask= 255.255.255.0
Subnet
Mask= 255.255.255.0
Gateway IP Address=
10.4.10.1
Gateway IP Address= 0.0.0.0
Remote IP Address= 10.4.10.3 Remote IP Address= 0.0.0.0
Management Port= LAN Management Port= FDL
7-8
T3SU 300 User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
61200217L1-1
Appendix A
Pinouts
The following tables give the pin assignments for the connectors
located on the T3SU 300 and for the V.35 interface card. For more
information on these connectors, see the chapter Installation and
Operation on page 2-1.
Table A-1. Control and Auxiliary Port Pin Assignments
RJ Pin#
Function
GND
RTS
TD
DSR
RD
CTS*
DTR
Direction
1
2
3
4
5
6
7
8
I
I
O
O
O
I
DCD
O
*Used for hardware flow control.
61200217L1-1
T3SU 300 User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
A-1
Appendix A. Pinouts
Table A-2. HSSI Interface Pin Assignments
Pin #
Pin # Direction
Description
(+ side) (- side)
1
2
26
27
Signal Ground (SG)
Receive Timing (RT)
DCE Available (CA)
Receive Data (RD)
Loopback Circuit C (LC)
Send Timing (ST)
O
O
O
O
O
3
28
4
29
5
30
6
31
7
8
9
32
33
34
35
36
37
38
39-43
44
Signal Ground (SG)
DTE Available (TA)
Terminal Timing (TT)
Loopback Circuit A (LA)
Send Data (SD)
Loopback Circuit B (LB)
Signal Ground (SG)
Five Ancillary to DCE
Signal Ground (SG)
Five Ancillary from DCE
Test Mode (TM)
I
I
I
I
I
10
11
12
13
14-18
19
20-23
24
25
I
45-48
49
50
O
O
Signal Ground (SG)
A-2
T3SU 300 User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
61200217L1-1
Appendix A. Pinouts
Table A-3. V.35 Interface Card Pin Assignments
Pin
A
B
C
D
E
F
H
J
CCITT
101
102
105
106
107
109
-
Description
Protective Ground (PG)
Signal Ground (SG)
Request to Send (RTS)
Clear to Send (CTS)
Data Set Ready
Received Line Signal Detector (CD)
Data Terminal Ready (DTR)
not used
-
L
-
Local Loopback (LL)
N
R
T
V
X
P
S
Y
AA
U
W
NN
-
Remote Loopback (RL)
Received Data (RD-A)
Received Data (RD-B)
Receiver Signal Element Timing (SCR-A)
Receiver Signal Element Timing (SCR-B)
Transmitted Data (SD-A)
104
104
115
115
103
103
114
114
113
113
-
Transmitted Data (SD-B)
Transmitter Signal Element Timing (SCT-A)
Transmitter Signal Element Timing (SCT-B)
External TX Signal Element (SCX-A)
External TX Signal Element (SCX-B)
Test Indicator (TI)
61200217L1-1
T3SU 300 User Manual
A-3
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix A. Pinouts
Table A-4. LAN Port Pin Assignments
Pin
1
Name
Description
TD+ The positive signal for the TD differential
pair. This signal contains the serial output
data stream transmitted onto the network.
TD- The negative signal for the TD differential
pair (pins 1 and 2).
2
3
RD+ The positive signal for the RD differential
pair. This signal contains the serial input
data stream received from the network.
N/A not used
4, 5
6
RD- The negative signal for the RD differential
pair (pins 3 and 6).
7, 8
N/A not used
A-4
T3SU 300 User Manual
61200217L1-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix B
Specifications Summary
SPECIFICATIONS AND FEATURES
This section describes the standard specifications and features
incorporated in the T3SU 300.
Network Interface
Clear channel, non-channelized DS3.
Line buildout: short (less than 50 feet) and long (greater than 50’).
Framing format: M13 and C-bit parity.
Line rate: 44.736 Mbps.
Line interface: 75-ohm BNC coax female connectors.
DTE Interface(s)
Integrated HSSI port.
Three (3) option slots accept any combination of interface cards.
HSSI ports are SCSI-II 50-pin female.
V.35 ports are high-speed, M34 female.
All option cards are hot swappable.
DTE Rates Supported
HSSI port(s) support 75 kbps to 44.2 Mbps.
V.35 port(s) support 75 kbps to 10 Mbps.
Bandwidth is selectable in 75 kbps increments.
Clocking
Loop (slaved to network receive clock)
Local (private network master)
61200217L1-1
T3SU 300 User Manual
B-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix B. Specifications Summary
VT 100 Terminal Interface
RJ-48, EIA -232 compatible, female DB-25 adapter provided.
Accessible through front or rear panel.
Remote configuration and statistics access available inband.
SNMP/Telnet
Integrated 10baseT ethernet and SLIP/ PPP (async) port.
MIB II, RFC 1213 and 1407 compliant.
ADTRAN Enterprise MIB for extended monitoring and control/
configuration.
Agency Approvals
FCC Part 15, Class A, UL and CUL
Environment
Operating: 0 to 50 °C (32 to 122 °F)
Storage: -20 to 70 °C (-4 to 158 °F)
Relative Humidity: Up to 95%, non-condensing
Physical
Dimensions: 11.625“D x 17.0“W x 1.7“H (for 1U high
19” rack space)
Weight: 7 lbs.
Power: 120 VAC, 9 W
B-2
T3SU 300 User Manual
61200217L1-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix C
Acronyms/Abbreviations
AIS..................... alarm indication signal
AMI ................... alternate mark inversion
ANSI ................. American National Standards Institute
async ................. asynchronous
BERT ................. bit error rate test
bps ..................... bits per second
BPV ................... bipolar violation
CA...................... communications equipment available
CCITT ............... Consultive Committee for International Telephony and Telegraphy
CCV................... C-bit coding violation
CD ..................... carrier detect
CES .................... C-bit errored seconds
CO ..................... central office
CPE.................... customer premise equipment
CRC ................... cyclic redundancy check
CS ...................... clear to send
CSES ................. C-bit severely errored seconds
CSU ................... channel service unit
CTS.................... clear to send
dB....................... decibel
DBU................... dial backup
DCD .................. data carrier detect
DCE................... data communications equipment
61200217L1-1
T3SU 300 User Manual
C-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix C. Acronyms/Abbreviations
DDS................... digital data service
DLCI.................. data link connection identifier
DS1 .................... digital signal level one
DS3 .................... digital signal level three
DSR ................... data set ready
DSU ................... data service unit
DTE ................... data terminal equipment
DTR ................... data terminal ready
ES ....................... errored seconds
EXZ .................... excessive zeros
FBE..................... F-bit errors
FCC .................... Federal Communications Commission
FDL.................... facility datalink
FEBE.................. far end block error
HSSI .................. high-speed serial interface
IP ........................ internet protocol
KA...................... keep alive
LAN ................... local area network
LCV ................... line coding violation
LED .................... light emitting diode
LES..................... line errored seconds
LL....................... local loopback
LOS.................... loss of signal
MBE................... M-bit errors
Mbps ................. megabits per second
MIB.................... management information base
ms....................... millisecond
NC...................... normally closed
NI ....................... network interface
NMS .................. network management system
NO ..................... normally open
NRZ ................... non-return to zero
OCU................... office channel unit
C-2
T3SU 300 User Manual
61200217L1-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix C. Acronyms/Abbreviations
OOF................... out of frame
OOS................... out of service
PCV ................... P-bit coding violation
PES .................... P-bit errored seconds
POP ................... point of presence
PPP .................... point-to-point protocol
PSES .................. P-bit severely errored seconds
PSTN ................. public switched telephone network
PVC ................... permanent virtual circuit
RD ..................... receive data
RDL................... remote digital loopback
RL ...................... remote loopback
RMA.................. return material authorization
RS ...................... request to send
RTS .................... request to send
Rx....................... receive
SEFS .................. severely errored framing seconds
SES .................... severely errored seconds
SLIP................... serial line internet protocol
SNMP ............... simple network management protocol
SR ...................... data set ready
SW56 ................. switched 56
sync ................... synchronous
TA ...................... terminal equipment available
TD ...................... transmit data
TDM .................. time division multiplexing
TM ..................... test mode
TR ...................... data terminal ready
Tx....................... transmit
UAS ................... unavailable seconds
WAN .................. wide area network
61200217L1-1
T3SU 300 User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
C-3
Appendix C. Acronyms/Abbreviations
C-4
T3SU 300 User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
61200217L1-1
Appendix D
Glossary
10baseT
Ethernet connector which implements the IEEE standard on 24-gauge,
unshielded twisted pair wiring.
AIS
alarm indication signal. An unframed all ones pattern that replaces the normal
traffic signal when a failure has been detected. This signal prevents logical con-
nections from terminating between devices.
AMI
alternate mark inversion. A bipolar line-coding format in T1 transmission sys-
tems whereby successive ones are alternately inverted.
ANSI
American National Standards Institute. A non-profit organization that coordi-
nates voluntary standards activities in the United States.
asynchronous
A method of data transmission which allows characters to be sent at irregular
intervals by preceding each character with a start bit, followed by a stop bit.
bandwidth
The bandwidth determines the rate at which information can be sent through a
channel (the greater the bandwidth, the more information that can be sent in a
given amount of time).
61200217L1-1
T3SU 300 User Manual
D-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix D. Glossary
baud rate
A measure of transmission speed over an analog phone line. Baud rate measures
the shortest signaling elements per second in the analog signal that a modem
sends over an analog phone line. Does not necessarily equal the bit rate.
BERT
bit error rate test. A test that uses any of a number of stress patterns to test T3,
T1, FT1, and DDS circuits.
bipolar
A signal containing both positive and negative amplitude components.
bipolar violation
See BPV.
bit
A binary digit representing a signal, wave, or state as either a one or a zero. A bit
is the smallest unit of information a computer can process.
bit error
The receipt of an encoded bit that differs from what was sent by the transmitter.
bit rate
The speed at which bits are transmitted, usually expressed in bits per second
(bps).
blue alarm (AIS)
An alarm used in T1/ T3 transmission. In a T3 circuit, blue alarms occur when
there is a transmission fault located either at or upstream from the transmitting
terminal. A blue alarm is when consecutive 1010’s are received in the informa-
tion bits.
bps
bits per second. The number of bits passing a specific point per second. Exam-
ples of common rates are kbps (one thousand bits per second) and Mbps (one
million bits per second). T3 operates at 44.736 Mbps.
BPV
bipolar violation. A violation in the alternate mark inversion line code for which
consecutive 1s are represented by pulses of opposite polarity. BPVs that are not
D-2
T3SU 300 User Manual
61200217L1-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix D. Glossary
intentional (B8ZS) are counted as errors. Could also be the presence of two con-
secutive 1 bits of the same polarity on the T-carrier line.
bridge
A data communications device that connects two or more networks and for-
wards packets between them.
byte
Generally, an 8-bit quantity of information. This term is used mainly in referring
to parallel data transfer, semiconductor capacity, and data storage.
carrier
The provider of the telecommunication services to the customer site. Carriers
can be local telephone companies, regional telephone companies, or any inter-
exchange carrier such as AT&T, Sprint, or MCI.
C-bit
An overhead bit in the DS3 string not used for framing, parity, or alarm indica-
tion.
CCITT
Consultive Committee for International Telephony and Telegraphy. A standards
organization that devises and proposes recommendations for international com-
munications. See also ANSI.
CD
carrier detect. A signal generated by a modem or DSU/ CSU indicating the pres-
ence of a carrier signal on a communications link.
channel
A transmission path between two or more termination points; also called a cir-
cuit, facility, line, link, or path.
channel bank
Equipment in a telephone central office or customer premises that performs
multi-plexing of lower speed digital channels into a higher speed composite
channel. The channel bank also detects and transmits signaling information for
each channel; thereby transmitting framing information so that time slots allo-
cated to each channel can be identified by the receiver.
61200217L1-1
T3SU 300 User Manual
D-3
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix D. Glossary
channel service unit
See CSU.
clocking
An oscillator-generated signal that provides a timing reference for a transmis-
sion link. A clock provides signals used in a transmission system to control the
timing of certain functions. The clock has two functions: (1) to generate periodic
signals for synchronization, and (2) to provide a time base.
control port
The electrical interface between the T3SU 300 and the control terminal. The con-
trol terminal is used to communicate commands to the unit.
CPE
CSU
customer premise equipment. All telecommunications terminal equipment
located on the customer premises, including telephone sets, private branch
exchanges (PBXs), data terminals, and customer-owned coin-operated tele-
phones.
channel service unit. A device used to connect a digital phone line coming in
from the phone company to either a multiplexer, channel bank, or directly to
another device producing a digital signal; for example, a digital PBX, a PC, or
data communications device. A CSU performs certain line-conditioning and
equalization functions, and responds to loopback commands sent from the cen-
tral office. A CSU regenerates digital signals. It monitors them for problems and
provides a way of testing the digital circuit.
CTS
clear to send. A signal on the DTE interface indicating that the DCE is clear to
send data.
data communications equipment
See DCE.
data service unit
See DSU.
dB
decibel. A unit of measure of signal strength; usually the relation between a
transmitted signal and a standard signal source.
D-4
T3SU 300 User Manual
61200217L1-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix D. Glossary
DCE
DDS
data communications equipment. Device that provides all the functions required
for connection to telephone company lines and for converting signals between
telephone lines and DTE. Also see DTE.
digital data service. A private line digital service for transmitting data end-to-
end at speeds of 2.4, 4.8, 9.6, and 56 kbps (and in some cases 19.2, 38.4, or 64
kbps). The systems can use central hub offices for obtaining test access, bridging
legs of multi-point circuits, and cross connecting equipment. DDS is offered on
an inter-LATA basis by AT&T and on an intra-LATA basis by the Bell operating
companies.
delay
The amount of time by which a signal is delayed. A round-trip transmission
delay measurement helps detect possible causes of protocol timeouts.
DLCI
datalink communications identifier. A unique number assigned to a PVC end
point in a frame relay network. Identifies a particular PVC endpoint within a
user's access channel in a frame relay network and has local significance only to
that channel.
DS1
DS3
DSU
DTE
digital signal level one. Twenty-four DS0 channels make up one DS1 (total band-
width is 1.544 Mbps).
digital signal level three. Equivalent of 28 DS1s and 672 DS0s (total bandwidth is
44.736 Mbps).
data service unit. A device designed to transmit and receive digital data on digi-
tal transmission facilities.
data terminal equipment. The end-user terminal or computer that plugs into the
termination point (DCE) of a communications circuit. The main difference
between the DCE and the DTE is that pins two and three are reversed.
61200217L1-1
T3SU 300 User Manual
D-5
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix D. Glossary
E1
Transmission rate of 2.048 Mbps on E1 communications lines. See also T1.
end device
The ultimate source or destination of data flowing through a network (some-
times referred to as DTE).
end user
Subscriber who uses (rather than provides) telecommunications services.
ES
errored seconds. A second with one or more coding violations (CVs).
ethernet
Transmission protocol for packet-switching LANs.
facilities
The equipment used by carriers to provide communication services.
far end
The distant end to that being considered. Not the end where testing is being car-
ried out.
FCC
FDL
Federal Communications Commission. The U.S. federal agency responsible for
regulating interstate and international communications by radio, TV, wire, satel-
lite, and cable.
facility datalink. FDL bits provide overhead communication between the termi-
nal equipment in ESF framing.
gateway
A device which enables information to be exchanged between two dissimilar
systems or networks.
host computer
The primary or controlling computer in a multiple computer operation.
D-6
T3SU 300 User Manual
61200217L1-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix D. Glossary
idle code
In a T3 circuit, an idle code consists of a sequence of 1100 over the entire payload
bandwidth.
in-band
Signaling (dialing, diagnostics, management, configuration, etc.) over the same
channel used for data.
IP
internet protocol. A protocol which provides for transmitting blocks of data
between hosts identified by fixed-length addresses.
LAN
local area network. A privately owned network that offers high-speed communi-
cations channels to connect information processing equipment in a limited geo-
graphic area.
local loopback (LL)
A type of test used to verify the operation of the local terminal equipment, the
CSU, and the connection between the two. The signal from the DTE is looped
back by the CSU and is sent back to the DTE.
loopback
The technique for testing the processing circuitry of a communications device.
May be initiated locally or remotely via a telecommunications circuit. Device
being tested will echo back received test data. The results are compared with the
original data.
LOS
M13
Mbps
loss of signal. Defined as a line state in which no pulses are received for 175 bit
positions.
DS1/ DS3 multiplexer that combines up to 28 DS1 channels into one DS3 chan-
nel. Uses two-stage, bit synchronous TDM.
Megabits per second (one million bits per second).
61200217L1-1
T3SU 300 User Manual
D-7
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix D. Glossary
MIB
management information base. A database of network management information
used by SNMP.
modem
Acronym for modulator/ demodulator. Equipment that converts digital signals
to and from analog signals. Used to send digital signals over analog phone lines.
monitor
To watch or listen to a signal non-intrusively.
multi-point circuit
A single communications circuit that has more than two terminations.
NC
normally closed. Relay switch contacts that remain closed when inactive.
near end
The unit on-site.
NI
network interface. The demarcation point between the CPE and the PSTN.
normally open. Relay switch contacts that remain open when inactive.
NO
NRZ
non return to zero. A mode in which the digital level is low for a 0 bit and high
for a 1 bit, and does not return to zero between successive 1 bits.
out-of-band
Signaling that is separated from the channel carrying information (voice, data,
video, etc.). Typically the separation is accomplished by a filter. The signaling
includes dialing and other supervisory signals.
point-to-point
Type of communications link that connects a single device to another single
device, such as a remote terminal to a host computer.
D-8
T3SU 300 User Manual
61200217L1-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix D. Glossary
POP
point of presence. Physical place within a LATA (local access and transport area)
where a long distance carrier or a cellular provider interfaces with the network
of the local exchange carrier (LEC). A POP is usually a building serving as the
point of termination which houses switches and transmission equipment.
protocol
A set of rules controlling the orderly exchange of information between stations
in data communications networks or systems.
PSTN
public switched telephone network. Usually refers to the world wide voice tele-
phone network available for public use.
red alarm
Unframed all ones signal (keep alive signal). A red alarm is declared on detec-
tion of LOS or OOF not caused by an alarm indication signal (AIS) that persists
for more than two seconds.
remote configuration
A feature designed into ADTRAN products that allows remote units to be con-
figured from a local unit or a VT 100 compatible terminal.
router
A device that supports communications between networks. Routers are similar
to bridges, with the exception that routers provide more functionality (such as
finding the best route between networks and providing network management
capabilities).
service
The provision of telecommunications to customers by a common carrier, admin-
istration, or private operating agency, using voice, data, and/ or video technolo-
gies.
service provider
A company that delivers or sells a telecom service.
SES
severely errored seconds. A second in which more than 320 code violations
(CVs) occurred or an OOF condition occurred.
61200217L1-1
T3SU 300 User Manual
D-9
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix D. Glossary
signaling
Communication between switches to set up and terminate calls.
SNMP
simple network management protocol. A control and reporting scheme widely
used to manage devices from different vendors. SNMP operates on top of the
Internet protocol.
SR
data set ready. A signal on the DTE interface that indicates if a connection exists
and if the devices are ready to start handshaking control signals so communica-
tions can begin.
synchronous
Communications in which the timing is achieved by sharing a single clock. Each
end of the transmission synchronizes itself with the use of clocks and informa-
tion sent along with the transmitted data.
T1
Transmission rates of 1.544 Mbps are available on T1 communication lines. Also
referred to as digital signal level 1 (DS-1). See also E1.
T3
Transmission rates of 44.736 Mbps are available on T3 communication lines. Also
referred to as digital signal level 3 (DS-3).
TDM
time division multiplexing. A technique for transmitting two or more signals at
the same time over a single communication medium. This is accomplished by
allocating channels to the bandwidth for specific increments of time.
TELNET
The standard TCP/ IP remote login protocol specified in RFC-854.
transceiver
A combination of transmitter and receiver providing both output and input
interfaces within a single device.
transmission
The signaling of data over telecommunications channels.
D-10
T3SU 300 User Manual
61200217L1-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix D. Glossary
V. 35
A standard for trunk interface between a network access device and a packet
network that defines signaling for data rates greater than 19.2 kbps.
VT 100
A non-intelligent terminal or terminal emulation mode used for asynchronous
communications. Used to configure the T3SU 300.
WAN
wide area network. A communications network serving geographically separate
areas. A WAN typically extends a LAN outside the building to link to other
LANs over telephone lines.
yellow alarm
A T3 yellow alarm is an indication sent back toward the source of a failed trans-
mit circuit in a DS3 two-way transmission path. The X-bits (X1 and X2) are set to
zero.
61200217L1-1
T3SU 300 User Manual
D-11
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix D. Glossary
D-12
T3SU 300 User Manual
61200217L1-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Index
pattern 6-9
A
active
blue alarm 4-4
blue alarm traps 3-16
port status 3-6, 4-5
agent 1-3
AIS 5-4, 5-5, 5-6
alarm
network state 4-2
alarm block 2-4
alarm history 5-2
alarm LED 2-9
V.35 2-2
alarm messages 4-2
alarm relay block 3-19
alarm state 4-2
answer on ring 3-22
applications 7-1
apply settings 3-7
auxiliary port 2-4, A-1
description 2-5
card slots 2-4
installation 2-4
C-bit coding violations 5-5
C-bit errored seconds 5-6
C-bit parity 3-3
setting baud rate 3-14
setting mode 3-13
clear errors 6-11
clear statistics 5-7
clock
source 3-9
clocking
B
bad boot sector 3-23
bad checksum 3-23
bad RAM address 3-23
bad RAM data 3-23
bandwidth 4-6
baud rate 3-14
BERT 6-10
external 3-9
invert 3-9
normal 3-9
61200217L1-1
T3SU 300 User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Index-1
Index
Com Eqpt Fail (NSA) 4-4
common equipment fail NSA 3-17
configuration
payload loopback test 6-6
remote payload loopback with
BERT test 6-8
DS3 network 3-2
DTE port 3-4
remote port payload loopback
test 6-8
remote 3-1, 3-2
system management 3-10
utilities 3-22
dial string 3-20
dialout on trap 3-21
DS3
configuration corrupt 3-23
configuration examples 7-1
connecting the unit to a terminal inter-
face 2-6
connection timeout 3-21
control port 2-6, A-1
CS 3-8, 4-7
CSES 5-6
CV 5-5
diagnostics 6-2
DS3 framing 3-3
DS3 framing type 4-2
DS3 interface 2-4, 2-6
configuration menu 3-2
DS3 network line 3-3
DS3 scrambler 3-4
DTE interface cards
installing 2-4
DTE loopback test 6-7
DTE port 2-4
configuration 3-4
DTE port 1
D
data link 3-4
data mode 6-3, 6-6
datalink state 4-2
date
description 2-5
setting 3-19
default setting
reverting to 3-22
desktop installation 2-3
diagnostics 2-8, 6-1
DS3
status information 4-5
BERT test 6-5
Eqpt Fail (NSA) 4-4
Eqpt Fail (SA) 4-4
line loopback test 6-4
remote DS3 loopback test 6-5
remote payload loopback with
BERT test 6-5
provided 2-1
equipment fail NSA 3-17
equipment fail SA 3-17
error
DTE ports 6-5
DTE loopback test 6-7
pay load and DTE loopback test
6-8
port status 3-7, 4-5
ethernet 3-13
EXZ 5-4
payload BERT test 6-6
Index-2
T3SU 300 User Manual 61200217L1-1
Download from Www.Somanuals.com. All Manuals Search And Download.
interface cable 2-2
interface cards 1-1
description 1-4
installation 2-4
V.35 1-4
interface type 3-6, 4-5
F
far end alarm traps 3-16
FBE 5-6
F-bit errors 5-6
flash load 3-22
fractional T3 service application 7-5
front panel
description 2-6
trap 3-15
IP hosts 3-13
IP security 3-13
G
gateway IP address 3-13
gateway node 3-13
H
LA 4-6
hangup 3-22
LAN port 2-4, 2-6, A-4
last modem response 3-22
HSSI 3-6, 3-7, 4-5
cable 2-2
HSSI card 1-4
HSSI interface 2-5
HSSI interface leads 4-6
HSSI port 1-1, A-2
leads 4-6
alarm 2-9
I
descriptions 2-9
DTE port 2-9
in service 2-9
LOS 2-9
network 2-9
RD 2-10
remote active 2-9
status 2-9
idle 4-4
idle signal traps 3-16, 3-17
idle timeout 3-21
in service LED 2-9
in test
network state 4-2
port status 4-5
in test LED 2-9, 2-10
inactive
port status 3-6, 4-5
included in shipment 2-1
initializing string 3-20
insert error 6-11
installation 2-1
installing interface cards 2-4
installing the unit 2-2
desktop installation 2-3
rackmount 2-2
line coding violations 5-4
line errored seconds 5-4
line length 3-3
line loopback test 6-4
link down 5-4
LL 4-7
loading new software 3-22
local IP address 3-12
61200217L1-1
T3SU 300 User Manual
Index-3
Download from Www.Somanuals.com. All Manuals Search And Download.
Index
local timing 3-3
logging out of the system 2-9
loopback tests 6-1
LOS 5-4
BERT test 6-9
pause between calls 3-21
payload and DTE loopback test 6-8
payload BERT test 6-6
payload loopback test 6-6
P-bit coding violations 5-5
P-bit errored seconds 5-5
P-bit severely errored seconds 5-5
PCV 5-5
performance parameters 5-4
pin assignments 2-3
auxiliary port A-1
LOS LED 2-9
M
M13 3-3
management port 3-13
maximum redial attempts 3-21
MBE 5-6
M-bit errors 5-6
menu structure 2-7
MIB 1-1, 1-3
modem application 3-13
modem mode 3-14
control connector A-1
HSSI port A-2
LAN port A-4
V.35 interface card A-3
pinouts A-1
point-to-point multiport application 7-3
port state 3-7
power up 2-2
PPP 2-5, 3-1, 3-13
N
N x 75k blocks 3-7
near end alarm trap 3-16
network LEDs 2-9
network manager 1-3
network port
status information 4-2
network state 4-2
normal
network state 4-2
not installed
rackmount installation 2-2
RD LED 2-10
port status 3-7
read community name 3-14
rear panel 2-3
description 2-3
receipt inspection 2-1
red alarm 4-2, 4-4
O
OOF 5-4, 5-6
OOF alarm 4-4
operation 2-1
out of frame traps 3-16
red alarm traps 3-16
refresh all remote statistics 5-7
remote active LED 2-9
remote configuration 3-2, 3-4
remote DS3 loopback test 6-5
remote IP address 3-13
P
password
default 3-18
setting 3-18
Index-4
T3SU 300 User Manual 61200217L1-1
Download from Www.Somanuals.com. All Manuals Search And Download.
remote login 2-8
terminal timeout 3-19
time
setting 3-19
timing
remote management application 7-7
remote payload loopback with BERT test
6-5, 6-8
reset all tests 6-11
local 3-3
loop 3-3
RL 4-7
RS 4-7
toggle all 3-16
toggle all traps 3-18
transmit clock 3-9
trap generation 3-15
S
save configuration 3-24
secondary phone number 3-20
SEFS 5-4
self test 3-22
results 3-23
severely errored framing seconds 5-4
single port application 7-1
SLIP 2-5, 3-1, 3-13
specifications B-1
SR 3-8, 4-7
UAS 5-4, 5-5, 5-6
unallocated 75k blocks 3-7
unit ID 3-19
unpacking the unit 2-1
updating the unit 3-22
utilities menu 3-22
statistics 5-1
statistics menus 2-8
status
DTE ports 4-5
V.35 3-6, 3-7, 4-5
cable 2-2
card 1-1, 1-4, A-3
leads 4-6, 4-7
VT 100 3-13
connection 2-6
status information
network port 4-2
status LED 2-9
subnet mask 3-12
T
waiting
T3 overview 1-2
TA 4-6
port status 3-7
waiting for DTE
port status 4-5
warranty 1-5
write community name 3-15
TD LED 2-10
TDM 1-1
TELNET 1-1, 1-3, 2-6, 3-13
terminal interface
connection 2-6
61200217L1-1
T3SU 300 User Manual
Index-5
Download from Www.Somanuals.com. All Manuals Search And Download.
Index
yellow alarm traps 3-16
Y
yellow alarm 4-2, 4-4
Index-6
T3SU 300 User Manual 61200217L1-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Product Support Information
Pre-Sales Inquiries and Applications Support
Please contact your local distributor, ADTRAN Applications Engineering, or
ADTRAN Sales:
Applications Engineering
Sales
(800) 615-1176
(800) 827-0807
Post-Sale Support
Please contact your local distributor first. If your local distributor cannot help,
please contact ADTRAN Technical Support and have the unit serial number
available.
Technical Support
(888) 4ADTRAN
Repair and Return
If ADTRAN Technical Support determines that a repair is needed, Technical
Support will coordinate with the Customer and Product Service (CAPS) de-
partment to issue a Return Material Authorization (RMA) number. For infor-
mation regarding equipment currently in house or possible fees associated
with repair, contact CAPS directly at the following number:
CAPS Department
(256) 963-8722
Identify the RMA number clearly on the package (below address), and return
to the following address:
ADTRAN Customer and Product Service
6767 Old Madison Pike
Progress Center
Building #6 Suite 690
Huntsville, Alabama 35807
RMA # _____________
Download from Www.Somanuals.com. All Manuals Search And Download.
Download from Www.Somanuals.com. All Manuals Search And Download.
|