ADIC Computer Drive FastStor User Manual

FastStor® 1 Quick Installation Guide  
Advanced Digital Information Corporation  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table of Contents  
Introduction ...................................................................................... 1  
Step 1. Unpacking the FastStor 1 .................................................... 2  
Step 2. Installing the FastStor 1 in a Rack ....................................... 2  
Step 3. Connecting Power Cable..................................................... 7  
Step 4. Removing the Transport Lock.............................................. 8  
Step 5. Running Power-On Selftest ................................................. 8  
Step 6. Setting the SCSI Address.................................................... 9  
Step 7. Connecting the SCSI Bus Cable.......................................... 9  
Step 8. Connecting the Ethernet Connector................................... 11  
Step 9. Restarting Your System..................................................... 11  
Step 10. BCR: Labeling cartridges................................................. 11  
FastStor 1 Quick Installation Guide  
i
Download from Www.Somanuals.com. All Manuals Search And Download.  
Advanced Digital Information Corporation  
FastStor 1  
ii  
FastStor 1 Quick Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Introduction  
This guide is designed to enable quick installation of the ADIC FastStor 1  
autoloader. For additional product and operation details, please refer to the ADIC  
FastStor 1 Installation and User Manual.  
The following steps summarize FastStor 1 installation:  
Unpack the FastStor 1  
Install the FastStor 1 in a rack  
Connect the power cable to the FastStor 1  
Turn on the FastStor 1  
Remove the transport lock by following the instructions displayed on the front  
panel  
Select the appropriate SCSI IDs and unit options  
Connect the SCSI interface cable, and optionally the Ethernet cable  
Install the backup application software and configure it for use with the  
FastStor 1  
Load cartridges into the removable magazines  
In order to complete full installation of the FastStor 1, the following additional  
materials are required:  
Simple hand tools (small Phillips screwdriver)  
SCSI Host adapter card with 68-pin wide HD or VHDC connector  
Tape application software that is verified with the FastStor 1  
Up to 8 pieces of the appropriate cartridge type to “stock” the FastStor 1 to full  
capacity.  
FastStor 1 Quick Installation Guide  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
Advanced Digital Information Corporation  
FastStor 1  
Front Panel of the FastStor 1  
Magazine LED  
Standby LCD  
Control  
Magazine  
front bezel  
front  
indicators switch  
display buttons  
bezel  
Figure 1. The FastStor 1's front side  
Step 1. Unpacking the FastStor 1  
Carefully unpack the unit from the shipping container. Save the container and  
packing materials in case you need to transport the FastStor 1 in the future. The  
packaging is specifically designed for the loader to ensure it is not damaged during  
transportation.  
Review the contents of the shipping container to be sure all parts were included in  
the shipment. A standard package for the FastStor 1 consists of the following items:  
A factory-assembled FastStor 1 unit containing two cartridge magazines.  
A Standard Accessory Kit containing:  
- 1 Warranty/Registration Card  
- Rack-Mount Hardware Kit  
- 2 Line Power Cords: one for USA/Japan and one for European  
power outlets  
- 1 VHDCI SCSI Interface Cable  
- 1 VHDCI LVD/SE SCSI Terminator  
- 1 Ethernet cable  
- Tool for Emergency Magazine Release  
- Media barcode label kit (contains media labels and cleaning  
cartridge labels)  
There may be variations of this list.  
Note: The FastStor 1 is not shipped with tape cartridges.  
Step 2. Installing the FastStor 1 in a Rack  
The FastStor 1 is designed for use in a 19” rack system using 1U of rack space.  
The length of the power cord and the SCSI cable may restrict the placement.  
2
FastStor 1 Quick Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Attention: The FastStor 1 is designed to operate in a horizontal position. Do not  
attempt to operate the FastStor 1 in any position other than horizontally. Also make  
sure that:  
The airflow around the front and back of the FastStor 1 is not obstructed.  
There is a minimum of 60cm free space in front of the unit to allow the  
operator to safely remove the magazines.  
The display and operator controls are easily accessed.  
The FastStor 1 is situated away from the floor and in a clean environment  
with temperatures within specifications.  
The Rack Mounting Kit includes the following items:  
Rail Left Assembly  
Rail Right Assembly  
Screw M6x12 (4 pieces)  
Screw M5x8 (2 pieces)  
Screw M4x12 (4 pieces)  
Nut M4 Hex (4 pieces)  
Washer to M6 (4 pieces)  
Washer to M4 (4 pieces)  
Recommended mounting tools:  
Folding rule or tape measure  
Phillips #2 screwdriver  
7 mm open-end wrench  
Note: The rails are mounted to the loader during transportation. Before mounting  
the rails into the rack, dismount the rails from the loader and remove the spacers  
between the rails and the loader.  
FastStor 1 Quick Installation Guide  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Advanced Digital Information Corporation  
FastStor 1  
Back  
Rail Right Assembly  
Rail Left Assembly  
Front  
Figure 2. Rack Mounting kit  
Installing the Rack Mounting Kit  
Determine the proper position of the rails in the rack.  
Caution: Consider rack stability when deciding where to place the FastStor 1.  
Hazardous conditions can result from uneven mechanical rack loading.  
FastStor 1 uses 1U of vertical rack  
space. The rails must be installed in a  
full U position. The bottom of the rails  
must be aligned with the bottom of a  
U. See Figure 3.  
Figure 3. Rack mount rail  
4
FastStor 1 Quick Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installing the “Rail Left Assembly”  
1. Measure the length between the rear rack mount rails and the front rack  
mount rails. If the measurement is shorter than the FastStor 1, move the two  
sets of screws M4x12, washers and nuts shown in Figure 4.  
2. Adjust the “Rail Left Assembly” to fit the measurement in step 1.  
3. Use a 7 mm open-end wrench together with the screwdriver to tighten the  
two M4x12 screws to fix the rail length. Note: Using more than two screws  
will increase the stability of the Rack Mounting Kit.  
4. Place the “Rail Left Assembly” on the left side of the rack, between the rear  
rack mount rail and the front rack mount rail.  
5. Mount the “Rail Left Assembly” at the desired height using one M6x12 screw  
in front (upper hole in rail only) and two M6x12 screws at the back. See  
Figure 5.  
Installing the “Rail Right Assembly”  
Follow the instruction for left side only using the “Rail Right Assembly” on the right  
side of the rack.  
Use these holes  
if rack depth is  
equal to or  
longer than the  
FastStor 1  
Step 1  
Use these holes  
if rack depth is  
shorter than the  
FastStor 1  
Rear Rack  
Mount Rail  
Step 5  
(Screw  
M6x12)  
Step 1  
Front Rack Mount Rail  
Step 3  
(Screw M4x12,  
nut and washer)  
Step 2  
Step 5  
(Screw M6x12)  
Figure 4. Mounting the Rack mounting kit to a rack  
FastStor 1 Quick Installation Guide  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Advanced Digital Information Corporation  
FastStor 1  
Figure 5 shows step 5 in the description:  
Rack mounting kit mounted in rack with  
one screw M6x12 in upper hole on both  
left and right sides.  
On the rear side, two screws must be  
used on both left and right sides.  
A total of six screws are used to install  
the rack mounting kit to the rack.  
Figure 5. Rack mounting kit  
mounted in rack  
Mounting the FastStor 1 to the Rack  
Make sure all screws in the Rack Mounting Kit are tightened properly before installing the  
FastStor 1 in the rack.  
Slide the FastStor 1 on the rails from the front of the rack, as shown in Figure 6. Then  
secure the FastStor 1 using one M6x12 screw in front of the rack on both left and right sides  
(see Figure 7), and one M5x8 on the back of the Rack Mounting Kit on both left and right  
sides (see Figure 8).  
Figure 7. Fasten the front of the  
Figure 6. Slide the FastStor 1 in  
FastStor 1 to the rack.  
from the front.  
6
FastStor 1 Quick Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Use one M5x8 screw on both left  
and right sides (M5-thread) to  
fasten the FastStor 1 to the rails’  
backside.  
Figure 8. Fasten the rear of the FastStor 1 to the rails.  
Step 3. Connecting Power Cable  
Before connecting the FastStor 1 to your host computer system, you should run the  
unit’s self-diagnostic test. (This preparation requires power to the FastStor 1.)  
Follow these steps to perform this test:  
1. Use the power cables from the accessories included in the shipment. Make  
sure you select the power cord suited for your location’s power system.  
2. Plug the power cable into the rear of the FastStor 1 (see Figure 9). Plug the  
other end of the cable into a properly grounded electrical outlet.  
Note: Reliable grounding depends on grounding in the AC electrical outlet in which  
the FastStor 1’s power cable is connected. Adding the FastStor 1 to an existing  
rack installation can cause a leaking current fault condition because of the  
summation of the leaking currents. For security, a 250V 2A (H) fuse is located near  
the power switch.  
3. Turn on the FastStor 1 by  
switching the Power Switch to  
“1”.  
If the transport lock is present,  
the loader will detect this and  
instruct the user to remove it.  
(See Step 4.)  
Figure 9. Power switch, fuse  
holder and power cord connection  
FastStor 1 Quick Installation Guide  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Advanced Digital Information Corporation  
FastStor 1  
Step 4. Removing the Transport Lock  
The robot mechanism is protected from damage during shipment by a screw  
holding the robotics in a locked position. This locking screw is marked with a red  
plastic tab protruding between the right magazine and the front panel assembly.  
This locking screw must be removed before the FastStor 1 can operate  
normally.  
Figure 10. Magazine lock marked with red plastic tab  
The locking screw is detected when the FastStor 1 is powered on. The display  
shows a message indicating the locking screw has been detected. The display  
instructs the user to remove the magazine to gain access to the locking screw.  
Remove the screw and reinsert the magazine. The loader will now continue its  
power-on sequence. See Step 5.  
Note: Keep the locking screw in a safe place. You will need it to lock the robot if  
you must return your FastStor 1 to the supplier for service or repair.  
Important: The warranty does not cover damage to the loader if the unit is shipped  
without the locking screw properly installed.  
Step 5. Running Power-On Selftest  
After the transport lock is removed, the loader will continue running it’s power-on  
selftest and performing an inventory of its cartridges.  
The word “Idle” and the cartridge map will appear on the default display screen. If  
the self-diagnostics and the inventory sequence complete successfully, the green  
LED illuminates. The FastStor 1 is now ready to be installed in the system.  
If a problem occurs during the power-on sequence, the FastStor 1 will show an  
error message on the display.  
8
FastStor 1 Quick Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Step 6. Setting the SCSI Address  
There is a LCD display on the front panel, and four control buttons. After the Power-  
on sequence is finished, select Menu and scroll down until you can select Setup.  
Then scroll down until the display looks like the figure below, and select SCSI  
setup.  
Exit  
SCSI setup  
Select  
The SCSI address is a unique address that identifies the unit connected to the  
SCSI bus. The FastStor 1 uses two SCSI addresses or IDs. One is for the loader  
robotics controller, and the other is for the tape drive. The SCSI addresses can be  
configured through the operator buttons and the display on the front panel. In most  
cases the default addresses can be used. The default SCSI address for the  
FastStor 1 robotics is 4, and the tape drive has its SCSI address set to 5.  
Exit  
Loader SCSI ID  
Select  
Exit  
Drive SCSI ID  
Select  
To set the SCSI addresses for the FastStor 1 and the built-in tape drive, see the  
FastStor 1 Installation and User Manual for details. At this time you can also  
reserve a magazine slot for a cleaning cartridge and set a security password.  
Changing some of these settings causes the FastStor 1 and the drive to  
automatically reboot.  
Step 7. Connecting the SCSI Bus Cable  
Guidelines before connecting the SCSI cable:  
A) Turn off the FastStor 1 power switch before connecting the SCSI bus cable  
to the FastStor 1.  
B) Make sure your host system is in a state where a new SCSI device can be  
safely connected to the SCSI bus.  
C) Do not exceed SCSI bus length restrictions.  
FastStor 1 Quick Installation Guide  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Advanced Digital Information Corporation  
FastStor 1  
1. Add the length of all external and internal SCSI cables on the bus  
2. Add 80 cm (31.5 inches) for the internal cable length in the FastStor 1.  
3. If the number of SCSI devices exceeds two, the maximum allowed length of  
an LVD SCSI bus is 12 m (39 ft).  
4. For an SE SCSI bus, be very careful regarding bus length. The normal  
combination has an SE bus transfer speed of 160 MB/s with a maximum  
bus length of 3 m (9.8ft) and up to 4 SCSI devices connected. If your SE  
system operates with a different transfer speed or has more than 4 SCSI  
devices, refer to the actual SCSI standard for complete bus length  
restrictions.  
D) Before you power on the FastStor 1 and restart the system, make sure the  
SCSI bus is properly terminated. If the FastStor 1 terminates the SCSI bus,  
ADIC recommends that you connect the terminator from the accessory kit  
box on the lower SCSI connector on the back plane.  
To connect the SCSI bus cable:  
1. On the rear of the FastStor 1, attach the SCSI cable’s device connector to  
the upper SCSI connector. (See Figure 11.)  
2. Secure the cable with the thumbscrews on the connector.  
3. Connect the other end of the SCSI cable to the appropriate SCSI adapter on  
your system, and then fasten it with the thumbscrews.  
4. If the FastStor 1 is the last device on the SCSI bus, install a SCSI bus  
terminator to the free SCSI connector on the FastStor 1. Make sure the  
terminator is the correct type for your SCSI system.  
5. It is possible to daisy chain several SCSI devices on the SCSI bus. If you do  
so, the terminator must be connected to the last device on the bus. Note  
that there are limitations to the SCSI cable length.  
Figure 11. SCSI cable and SCSI terminator connection  
10  
FastStor 1 Quick Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Step 8. Connecting the Ethernet Connector  
To connect the FastStor 1 to the Ethernet port, use the provided cable from the  
accessory kit box.  
1. Insert one end of the cable into the FastStor 1 Ethernet port. Push until it  
snaps into place. (The open port shown in Figure 11 is for Ethernet  
connection.)  
2. Connect the other end of the cable to a normal 10/100 BaseT Ethernet  
outlet.  
Step 9. Restarting Your System  
ADIC recommends that all external SCSI devices, including the FastStor 1, are  
powered on before you restart the computer system. After restarting your system,  
including the FastStor 1, the FastStor 1 runs a power-on selftest (as in Step 5  
above). When the display reports that the FastStor 1 is in the “Idle“ state and the  
green LED is on, the FastStor 1 is ready for further configuration and operation.  
Note: The tape drive needs up to 40 seconds from power on until it’s active on the  
SCSI bus. It is recommended to turn on the power at least 40 seconds before the  
computer system is started.  
Step 10. BCR: Labeling cartridges  
If your loader is equipped with a barcode reader and you want to use this  
functionality, you must attach barcode labels to the cartridges.  
Note: You must use FastStor 1-specific barcode labels to ensure reliable  
functionality of the barcode reader. Cartridge labels must be oriented on the  
cartridges as shown in the following figure (locking feature on the left.)  
Figure 12. Positioning of barcode label for LTO cartridges.  
FastStor 1 Quick Installation Guide  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  

2Wire Network Router 2WIRE2071 User Manual
Acoustic Research Home Theater System ARHC4 User Manual
Actron Automobile Parts 9615 User Manual
Agilent Technologies Computer Drive U7242A User Manual
American Standard Outdoor Shower 2000500 User Manual
Ask Proxima Projector IN35W User Manual
Avenview Switch SW HDSDI 8X1 User Manual
Baldor Tablet MN1851 User Manual
Beko Refrigerator CT7831S User Manual
Beko Refrigerator D1 8410 SM User Manual