ClearGain® Dual Inline TMAs
Americas
As mobile usage continues to increase, service providers are faced with the challenge of optimizing
and expanding their wireless networks to provide new and existing services. ADC’s ClearGain®
Tower-Mounted Amplifiers (TMAs) minimize the cost of network expansion and improve the
quality of service, allowing carriers to increase profitability from new and existing services.
ClearGain TMAs improve signal quality by boosting the uplink (RX) signal of a mobile system
immediately after the antenna. This compensates for the loss in signal strength that occurs
when the signal is passed through the coaxial feeder cable to the base transceiver station (BTS)
at the base of the tower. These TMAs perform this amplification with the lowest possible noise
contribution, resulting in a substantial increase in receiver performance and an improvement in
overall coverage. These improvements in quality of service allow mobile subscribers to place more
calls, make longer calls, and successfully complete calls in an expanded geographic area, resulting
in increased revenue.
Benefits:
• Small size and low weight. Allows for easy installation with minimal visual impact and
in weight-restricted implementations.
• Improved uplink coverage. TMAs enable base stations to receive mobile signals more clearly
in a wider coverage area than could otherwise be achieved.
• Increased RF performance. By improving signal quality and/or reducing mobile phone power
transmission, TMAs provide more successful call attempts, a reduction in dropped calls,
maximized data rate, improved call quality and the extension of handset battery life.
• Fully AISG compliant.
w w w . a d c . c o m
•
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
Download from Www.Somanuals.com. All Manuals Search And Download.
ClearGain® Dual Inline TMAs
Americas
AWS Dual Inline Typical Specifications
ELECTRICAL
Nominal Impedance of RF Inputs and Outputs:
50 Ohm
Frequency Range
TX:
2110 – 2155MHz
1710 – 1755MHz
RX:
Passband (RX)
Gain:
12db
Noise Figure:
≤1.4dB
Dynamic Range:
Input at 1 DB Gain Compression:
0utput IP3:
+13dBm
+25dBm
≤2.0dB
>50dB
Bypass Insertion Loss:
Isolation in Tx Path:
Insertion Loss of TX Path (TX to ANT):
Passband Return Loss
Tx Band:
0.5dB
18dB
18dB
>75dB
Rx Band:
Rx Rejection in Tx Band:
PHYSICAL
Dimensions (HxWxD):
Weight:
210 mm x 166 mm x 81 mm
4.5kg
Housing:
Aluminium
CONNECTORS
Antenna Connector:
BTS Connector:
7/16 DIN Female
7/16 DIN Female
ENVIRONMENTAL
Operating Temperature:
Lightning Protection:
-40°C to +60°C
BTS Port 10kA 8/20us
ANT Port 10kA 8/20us
VIBRATION
Storage:
ETS3019-1-1
Transport:
Operation:
ETS3019-1-2
ETS3019-1-4 Class 4.1E
REGULATORY
EMC:
ETS 300 342-3
APPROVALS
AISG:
AISG 1.1
CE:
Per IEC 61000 and IEC 60950
QUALITY
MTBF:
500,000 hours
ADC is an active member
of the Antenna Interface
Standard Group.
w w w . a d c . c o m
•
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
3
Download from Www.Somanuals.com. All Manuals Search And Download.
ClearGain® Dual Inline TMAs
Americas
STRB-NF-NM-G-KIT
STRB-NM-NF-G-KIT
STRB-DM-DF-G-KIT
STRB-DF-DM-G-KIT
Bias-T Units
ADC’s newly enhanced Bias-T Units can be used indoors and outdoors in conjunction with the ClearGain
power distribution unit (PDU). These versatile units, also known as DC current injectors, insert DC power
into the coaxial cable and extract alarm and monitoring signals from the coaxial cable.
PRODUCT CONFIGURATION
Main path connectors:
DC injection/Sample port connector:
Mounting and grounding:
Refer to ordering information for configurations
TNC jack (female)
/M8 / brk (MH - bulkhead mounting/
M - screw / brk - bracket)
TECHNICAL DATA
Impedance:
50 ohms
Frequency range:
Return loss:
800 to 2200 MHz
> 19 dB
Insertion loss:
< 0.2 dB
RF CW power:
500 W
PIM 3rd order:
-108 dBm
Surge current handling capability:
Operating temperature:
Waterproof degree:
DC injection / DC bypass current:
DC supply / DC bypass voltage:
MTBF:
3kA single
-40°C to + 65°C
IP 65
< 2 A
< 48 V
600,000 hours
125 mm x 110 mm x 45 mm
(4.9 in x 4.3 in x 1.8 in)
0.8 kg (1.8 lbs.)
Size:
Weight:
w w w . a d c . c o m
•
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
ꢀ
Download from Www.Somanuals.com. All Manuals Search And Download.
ClearGain® Dual Inline TMAs
Americas
Dual Inline Power Distribution Unit
Time and space are important considerations when selecting and installing wireless components at
base transceiver station sites. The simple, compact design of ADC’s ClearGain Power Distribution
Unit (PDU) is intended to help service providers save both. From a compact unit that is easily mounted
on a wall or in a rack, the ClearGain PDU provides power and alarming for up to three ClearGain
Tower-Mounted Amplifiers.
Features:
• Provides power and alarm functions for on-site monitoring of up to three dual-inline masthead
units (MHUs)
• Monitors condition of feeder cable
• Wall or rack-mountable to fit available space
• LED indicators for alarm functions
• Simple, compact design allows for easy installation and connections
• AISG compliant
The ClearGain Dual Inline TMA system is modular, consisting of an MHU and a PDU, providing full
compatibility with all base stations.
The ClearGain Dual Inline PDU is an integrated unit that provides power and alarm functions for the
ClearGain TMA system. The PDU monitors the current of the MHU. If an MHU fails, the ClearGain Dual
Inline PDU gives an alarm indication. The ClearGain Dual Inline PDU also monitors the condition of the
feeder cable. Alarm indicators identify failure in the feeder cable or MHUs and in which MHU the
failure occurred, providing fast and easy on-site diagnostics.
The flexible design of the ClearGain Dual Inline PDU allows it to be rack-mounted or mounted indoors
on the wall or on the side of a BTS cabinet.
An external Bias-T unit is used in conjunction with the Dual Inline PDU and is designed to connect
directly into the BTS coaxial connector. Bias-T units are available with various connector types, with
gas tube arrestors for lightning protection on the ANT and MHU ports. Quarter wave stub lightning
protection is integrated on the BTS port of the Bias-T units.
w w w . a d c . c o m
•
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
5
Download from Www.Somanuals.com. All Manuals Search And Download.
ClearGain® Dual Inline TMAs
Americas
Dual Inline Power Distribution Unit Typical Specifications
ELECTRICAL
Input Voltage:
20-56 Vdc positive/negative ground
Output Voltage:
Maximum Current Draw:
PHYSICAL
3x16 Vdc each
3A
Dimensions (HxWxD):
Weight:
43 x 196 x 103 mm
1 kg
Color:
Silver
CONNECTORS
Output for MHUs:
Power Connector:
General Alarm Connector:
General Communications Connector:
SMB, male (qty 3)
4-pin male
3-pin male
3-pin male
INDICATORS
Green OK/NOK LEDs
Red General Alarm LED
ALARM OUTPUT
Alarm output is isolated 3-pin relay
connection. Normally open and
normally closed connection available.
ENVIRONMENT
Storage:
ETS3019-1-1
Transportation:
Operation:
ETS3019-1-2
ETS3019-1-3
Housing:
IP40
Temperature Range (Indoor Use):
Lightning Protection:
APPROVALS
-20°C to +65°C
IEC 1000-4-5 EMC
CE
QUALITY
MTBF 250,000
Manufactured under ISO 9001 quality system
ACCESSORIES
Basic Accessories:
Power supply cable (10 m), alarm cable (10 m),
communications cable (10 m), grounding cable (2 m)
and wall mounting screws
Optional Accessories:
Mounting hardware for 19” rack mount
ADC is an active member
of the Antenna Interface
Standard Group.
O rd e r i n g I n f o r m a t i o n
Description
Catalog Number
ClearGain Masthead Unit
CG0AWSDD155DT00
Bias-T Kits*
7/16 DIN male to BTS, 7/16 DIN female to ANT
7/16 DIN female to BTS, 7/16 DIN male to ANT
N female to BTS, N male to ANT
N male to BTS, N female to ANT
STRB-DM-DF-G-KIT
STRB-DF-DM-G-KIT
STRB-NF-NM-G-KIT
STRB-NM-NF-G-KIT
Dual Inline Power Distribution Unit – Includes power cable and grounding cable CG0000000000PFM
*Bias-T, DC Cable 4.25 meters (SMB to TNC), Grounding Cable 1.5 meters (one end terminated)
Approved for use with ADC supplied Masthead Units only.
w w w . a d c . c o m
•
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
6
Download from Www.Somanuals.com. All Manuals Search And Download.
ClearGain® Dual Inline TMAs
Americas
Creating a Bill of Materials
A typical site includes three components in various quantities.
You have one TMA option:
1. CG0AWSDDI55DT00
AWS Dual Inline TMA
The TMAs include:
• Mounting hardware
• Grounding cable/strap (length 1.5 meters)
Ordering information: Order one per sector
You have four Bias-T options (based on connector type and orientation):
1. STRB-DF-DM-G-KIT
2. STRB-DM-DF-G-KIT
3. STRB-NF-NM-G-KIT
4. STRB-NM-NF-G-KIT
DIN Female to BTS Port, DIN Male to ANT Port
DIN Male to BTS Port, DIN Female to ANT Port
N Female to BTS Port, N Male to ANT Port
N Male to BTS Port, N Female to ANT Port
The Bias-Ts include: • Grounding cable/strap (length 1.5 meters)
• Bias-T cable; go from Bias-T to the PDU (length 14 feet)
Ordering information: Order one per sector
You have one PDU option:
1. CG0000000000PFM
Dual Inline PDU
The PDU includes:
• Mounting Hardware
• Power Cable (length 10 meters)
• Alarm Cable (length 10 meters)
• Grounding Cable/strap (length 1.5 meters)
Ordering information: Order one per site
Optional Accessories:
Longer Bias-T Cable CG-PDU-30CABLE (30 foot Bias-T cable)
PDU Rack Mounting Brackets AUX-000076 (19" rack mounting bracket)
AUX-000076 & EB-17P (23" mounting bracket)
AUX-000084 (Siemens cabinet mounting bracket)
w w w . a d c . c o m
•
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
ꢁ
Download from Www.Somanuals.com. All Manuals Search And Download.
From North America, Call Toll Free: 1-800-366-3891 • Outside of North America: +1-952-938-8080
Fax: +1-952-917-3237 • For a listing of ADC’s global sales office locations, please refer to our website.
ADC Telecommunications, Inc., P.O. Box 1101, Minneapolis, Minnesota USA 55440-1101
Specifications published here are current as of the date of publication of this document. Because we are continuously
improving our products, ADC reserves the right to change specifications without prior notice. At any time, you may
verify product specifications by contacting our headquarters office in Minneapolis. ADC Telecommunications, Inc.
views its patent portfolio as an important corporate asset and vigorously enforces its patents. Products or features
contained herein may be covered by one or more U.S. or foreign patents. An Equal Opportunity Employer
105188AE 8/07 Original © 2007 ADC Telecommunications, Inc. All Rights Reserved
Download from Www.Somanuals.com. All Manuals Search And Download.
|