SignalOn® Series
RF Signal Management
Advanced broadband services are being developed and launched at an ever-accelerating
pace. While these services vary, they have one thing in common. Whether it be high-speed
data, video-on-demand, or IP telephony, broadband subscribers expect a reliable, high-quality
experience at an affordable price.
ADC’s SignalOn® Series has been designed with these demanding service requirements in mind.
This next generation RF signal management platform provides unmatched density, RF performance,
and reliability—all at a competitive price. With its patented hitless “make-before-break” attenuator
circuit design, maintaining your RF signal network has never been easier.
w w w . a d c . c o m
•
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
Download from Www.Somanuals.com. All Manuals Search And Download.
SignalOn® Series
RF Signal Management
Chassis
20-Position, 5 RU Chassis
32-Position, 4 RU Drawer
8-Position, 2 RU Chassis
4-Position, 1 RU Chassis
Catalog Number
N - C __ __ __ __ B
Type
Power Kit
32D 32-position, Drawer
20V 20-position, Vertical
08H 8-position, Horizontal
04H 4-position, Horizontal
02H 2-position, Horizontal
N
Y
No
Yes*
* 20 and 8-position only
2-Position, 1 RU Chassis
O rd e r i n g I n f o r m a t i o n
Description
Catalog Number
Passive Chassis
32-position high-density chassis, 4 RU, black
20-position chassis, 5 RU, black
20-position chassis, 5 RU, NEBS
8-position chassis, 2 RU, black
8-position reversible chassis, 2 RU, black
4-position chassis, 1 RU, black
2-position chassis, 1 RU, black
Active Chassis
N-C32DNB
N-C20VNB
N-C20VN-NEBS
N-C08HNB
N-C08HNB-R
N-C04HNB
N-C02HNB
20-position powered chassis, 5 RU, black
20-position powered chassis, 5 RU, NEBS
8-position powered chassis, 2 RU, black
N-C20VYB
N-C20VY-NEBS
N-C08HYB
w w w . a d c . c o m
•
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
3
Download from Www.Somanuals.com. All Manuals Search And Download.
SignalOn® Series
RF Signal Management
Passives: Introduction
The SignalOn® Series, combined with the
innovative cable management of the chassis,
provides engineers with a variety of products to
simplify the RF signal management challenge.
Passives:
RF Splitter/Combiner Modules
5 MHz to 1 GHz
Plain Splitter/Combiner Pad and Monitor Module
Module
with Make-Before-Break
Attenuation
Catalog Number
Features
N - M __ __ __ __ __ __
• Industry's highest density with standard F
and BNC connectors
Module Type
Make-Before-Break
Attenuation**
• Industry's best performance and specifications
P
C
S
Plain splitter/
combiner
• Individual performance certificate shipped
M0 0 dB default
M6 6 dB default
with every module
Combiner with
pad/monitor
• Patented make-before-break attenuator pad
design for hitless signal balancing
Configuration
Splitter with pad/
monitor
• Chassis supports both passive and active
modules
12
14
18
2:1
4:1
8:1
X
Splitter and
• Clear chassis door provides protection and
combiner with
pad/monitor (2 x
4:1 module only)
clear view of modules
• Clear attenuator pad covers and patented
32 3 x 2:1*
24 2 x 4:1*
pad guides for simplified maintenance
• High quality, precision F or BNC connectors
Connector Type
• Designed to exceed NEBS requirements for
F
F
grounding/bonding
B
BNC
• Independent EMI near and far-field testing
• Ten year warranty on all passive modules
• Available in 1 RU, 2 RU, 4 RU and 5 RU chassis
• NEBS Level 3 compliant
*3 x 2:1 and 2 x 4:1 housed in a single module.
**Leave last two digits blank for plain modules.
Selection of default pad option for pand and monitor modules
The make before break attenuation feature requires that a default attenuation padding value be chosen
for the module. The two options are:
M0 – 0 dB loss on the splitter or combiner leg when attenuator pad is removed
The M0 option is used in systems where the attenuator pad values will range from 0 dB to 10 dB.
M6 – 6 dB loss on the splitter or combiner leg when attenuator pad is removed
The M6 option is typically used in systems where the attenuator pad values range from 10 dB to
25 dB. In this situation, the additional 6 dB of loss that is placed in line when the pad is removed
will help to limit overdriving active devices further downstream and will help limit transmitter laser
clipping, and overdriving of RF amplifiers in the distribution plant.
w w w . a d c . c o m
•
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
4
Download from Www.Somanuals.com. All Manuals Search And Download.
SignalOn® Series
RF Signal Management
O rd e r i n g I n f o r m a t i o n
Description
Catalog Number
Plain Splitter/Combiner Modules
BNC connector
2:1 plain
N-MPB12
4:1 plain
N-MPB14
8:1 plain
N-MPB18
3 x 2:1 plain
2 x 4:1 plain
2:1 plain
N-MPB32
N-MPB24
F connector
N-MPF12
4:1 plain
N-MPF14
8:1 plain
N-MPF18
3 x 2:1 plain
2 x 4:1 plain
0 dB default
N-MPF32
N-MPF24
BNC connector
2:1 combiner with monitor
2:1 splitter with monitor
N-MCB12M0
N-MSB12M0
N-MCB24M0
N-MSB24M0
N-MXB24M0
N-MCB32M0
N-MSB32M0
N-MCB14M0
N-MSB14M0
N-MCB18M0
N-MSB18M0
N-MCB12M6
N-MSB12M6
N-MCB24M6
N-MSB24M6
N-MXB24M6
N-MCB32M6
N-MSB32M6
N-MCB14M6
N-MSB14M6
N-MCB18M6
N-MSB18M6
2x4:1 combiner with monitor
2x4:1 splitter with monitor
2x4:1 splitter/combiner with monitor
3x2:1 combiner with monitor
3x2:1 splitter with monitor
4:1 combiner with monitor
4:1 splitter with monitor
8:1 combiner with monitor
8:1 splitter with monitor
6 dB default
2:1 combiner with monitor
2:1 splitter with monitor
2x4:1 combiner with monitor
2x4:1 splitter with monitor
2x4:1 splitter/combiner with monitor
3x2:1 combiner with monitor
3x2:1 splitter with monitor
4:1 combiner with monitor
4:1 splitter with monitor
8:1 combiner with monitor
8:1 splitter with monitor
w w w . a d c . c o m
•
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
5
Download from Www.Somanuals.com. All Manuals Search And Download.
SignalOn® Series
RF Signal Management
O rd e r i n g I n f o r m a t i o n
Description
Catalog Number
Splitter/Combiner with Pad and Monitor Modules
F connector
0 dB default
2:1 combiner with monitor
2:1 splitter with monitor
N-MCF12M0
N-MSF12M0
N-MCF24M0
N-MSF24M0
N-MXF24M0
N-MCF32M0
N-MSF32M0
N-MCF14M0
N-MSF14M0
N-MCF18M0
N-MSF18M0
N-MCF12M6
N-MSF12M6
N-MCF24M6
N-MSF24M6
N-MXF24M6
N-MCF32M6
N-MSF32M6
N-MCF14M6
N-MSF14M6
N-MCF18M6
N-MSF18M6
2x4:1 combiner with monitor
2x4:1 splitter with monitor
2x4:1 splitter/combiner with monitor
3x2:1 combiner with monitor
3x2:1 splitter with monitor
4:1 combiner with monitor
4:1 splitter with monitor
8:1 combiner with monitor
8:1 splitter with monitor
6 dB default
2:1 combiner with monitor
2:1 splitter with monitor
2x4:1 combiner with monitor
2x4:1 splitter with monitor
2x4:1 splitter/combiner with monitor
3x2:1 combiner with monitor
3x2:1 splitter with monitor
4:1 combiner with monitor
4:1 splitter with monitor
8:1 combiner with monitor
8:1 splitter with monitor
w w w . a d c . c o m
•
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
6
Download from Www.Somanuals.com. All Manuals Search And Download.
SignalOn® Series
RF Signal Management
Passives:
Directional Coupler Modules
5 MHz to 1 GHz
Catalog Number
N - MD __ __ __ __ __
Connector Type
Application Type
Rear narrowcast signal port
F
F
R
B
BNC
DC Value
Circuit Quantity
09
12
20
9 dB
Directional Coupler
1
Single circuit
Triple circuit
12 dB
20 dB
3
V12 12 dB variable
O rd e r i n g I n f o r m a t i o n
Description
Catalog Number
Directional Coupler Modules
BNC connector
9 dB
Triple circuit
Single circuit
Triple circuit
6x variable
N-MDB309R
N-MDB112R
N-MDB312R
N-MDB6V12R
N-MDB120R
N-MDB320R
N-MDF309R
N-MDF112R
N-MDF312R
N-MDF6V12R
N-MDF120R
N-MDF320R
12 dB
20 dB
Single circuit
Triple circuit
Triple circuit
Single circuit
Triple circuit
6x variable
F connector
9 dB
12 dB
20 dB
Single circuit
Triple circuit
w w w . a d c . c o m
•
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
7
Download from Www.Somanuals.com. All Manuals Search And Download.
SignalOn® Series
RF Signal Management
Passives: Conditioning and Monitor Modules
Features
• Typically placed at the input to the forward
path optical transmitter, this module allows
for conditioning and grooming of the RF
signal gain and slope. It is designed as 1:1
input to output with two MBB circuits in
series for pad and EQ placement.
• -20 dB front facing monitor port
• NEBS Level 3 compliant
Triple C & M
F-Connectors
O rd e r i n g I n f o r m a t i o n
Description
Catalog Number
Conditioning and Monitor Modules; triple circuit, 20 dB, 0 dB default
BNC connector
N-MMB320FM0
N-MMF320FM0
F connector
Attenuation
Pad
Equalization
(EQ) Pad
In
Out
-20 dB
(monitor)
Conditioning and monitor module schematic
w w w . a d c . c o m
•
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
8
Download from Www.Somanuals.com. All Manuals Search And Download.
SignalOn® Series
RF Signal Management
Passives: L-Band Satellite Splitter Modules
950 MHz to 2.15 GHz
ADC’s new L-Band series satellite splitter modules are engineered for the highest performance in
the 950 MHz to 2.15 GHz frequency range. These plain splitter/combiner modules feature dual port
power-passing capability for powering LNB’s. All L-Band modules are available with precision F
or BNC connectors, and are NEBS Level 3 compliant.
Catalog Number
N - ML __ __ __
Connector Type
Configuration
F
F
12
14
18
2:1
4:1
8:1
B
BNC
32 3 x 2:1*
24 2 x 4:1*
*Housed in a single module.
L-Band
Satellite Splitter
O rd e r i n g I n f o r m a t i o n
Description
L-Band Satellite Splitter Modules
Catalog Number
BNC connector
2:1 splitter
N-MLB12
N-MLB14
N-MLB18
N-MLB32
N-MLB24
N-MLF12
N-MLF14
N-MLF18
N-MLF32
N-MLF24
4:1 splitter
8:1 splitter
3x2:1 splitter
2x4:1 splitter
2:1 splitter
4:1 splitter
8:1 splitter
3x2:1 splitter
2x4:1 splitter
F connector
All L-Band modules feature dual port power passing capability.
Pass
Pass
1
2
3
4
1
2
Pass
Pass
Pass
2-Way Splitter
4-Way Splitter
1
2
3
4
5
6
7
8
Pass
8-Way Splitter
w w w . a d c . c o m
•
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
9
Download from Www.Somanuals.com. All Manuals Search And Download.
SignalOn® Series
RF Signal Management
Actives: Introduction
Today’s broadband services require high-quality
headend infrastructure that offers excellent
performance, reliability and design flexibility.
Furthermore, your infrastructure solution should
maximize the uptime of carrier-class services like
VoIP, VOD and HSD as applications evolve and
your network changes.
Leveraging over a decade of RF amplifier design
experience, ADC’s SignalOn® amplifiers have been
engineered to meet these demanding service
requirements. Featuring operation from 50 MHz to
1 GHz, the amplifiers offer excellent performance
and reliability. SignalOn amplifiers and associated
power supplies can be housed in the same chassis
as the SignalOn passive products for increased
design flexibility. With its electronically variable gain
and slope controls, you can adjust signal levels in
your network with no service downtime.
Amplifier
(front view)
SignalOn amplifiers feature non-service-affecting
gain and slope controls. This capability along with
the patented make-before-break attenuator pad
design of the splitters and combiners, allow for
"hitless" RF signal adjustment—critical for today's
carrier-class broadband service applications.
20-Position, 5 RU Powered Chassis
(with mixture of passive
and active modules)
Features
• Operation from 50 MHz to 1 GHz
• GaAs technology with near-100% surface
mount design for high performance
20-Position, 5 RU Powered Chassis
(rear view)
• Meets MIL-202 specs for quality and reliability
• Mounts in same SignalOn chassis as passive
modules for maximum design flexibility
• Digitally variable gain and slope control for
non-service-affecting signal level adjustments
• 20 dB monitor points on both input and
output signals for testing and troubleshooting
8-Position, 2 RU Powered Chassis
• "Blind-mate" power bus connector with
(front view)
gold-on-gold contacts; requires no cabling
• Chassis-mounted AC-DC and DC-DC power
supply options
• Redundant powering with dual load shared
power supplies for increased availability
• External +24 Vdc powering option
• NEBS Level 3 compliant
8-Position, 2 RU Powered Chassis
(rear view)
w w w . a d c . c o m
•
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
10
Download from Www.Somanuals.com. All Manuals Search And Download.
SignalOn® Series
Actives: Forward Path Amplifier
Actives: Amplifier Modules
Amplifier
(front view)
O rd e r i n g I n f o r m a t i o n
Description
Catalog Number
Forward Path Amplifier Modules
BNC connector
20 dB
30 dB
20 dB
30 dB
N-MAB20FA
N-MAB30FA
N-MAF20FA
N-MAF30FA
F connector
PeRFoRMANCe ATTRiBUTe
Bandwidth
20 dB Forward Amplifier
50-1000 MHz
30 dB Forward Amplifier
50-1000 MHz
optimum RF input
Minimum full gain
Gain adjustment range
Tilt adjustment range
+20 dBmV per channel
20.0 dB
+10 dBmV per channel
30.0 dB
10 +/-1 dB in 0.5 dB steps
10 +/-1 dB in 0.5 dB steps
10 +/-1 dB @ 50 MHz in 0.5 dB steps
10 +/-1 dB @ 50 MHz in 0.5 dB steps
+/- 0.4 dB from 50 to 870 MHz
+/- 0.5 dB from 870 to 1000 MHz
+/- 0.45 dB from 50 to 870 MHz
+/- 0.65 dB from 870 to 1000 MHz
Gain flatness
Return loss,
input and output ports
-19.0 dB from 50 to 870 MHz
-16.5 dB from 870 to 1000 MHz
-18.0 dB from 50 to 870 MHz
-15.0 dB from 870 to 1000 MHz
7.3 dB from 50 to 870 MHz
7.6 dB from 870 to 1000 MHz
5.7 dB from 50 to 870 MHz
6.2 dB from 870 to 1000 MHz
Noise figure
CTB1
-73.1 dB
-81.7 dB
-78.2 dB
-78.9 dB
-84.5 dB
-83.7 dB
CSo1
iMD1
Monitor ports
Power dissipation
operating temperature
Dimensions
-20 dB test point for both RF input and RF output
17W max
0 - 50 degrees C
8.55"H x 1.67"W x 7.81"D
gold-on-gold, slide-on contacts
Meets MIL-STD-202 Method 107
Meets GR-63-Core Section 5.4.2
Meets MIL-STD-202 Method 213
Meets MIL-STD-202 Method 108
Meets NEBS Level 3
Power connector
Thermal shock
office vibration
Mechanical shock
Accelerated aging
NeBS
Note: Measured with 110 channel loading and optimum RF input level at full gain and no tilt. Specifications are typical
worst-case numbers across the given frequency range, unless otherwise noted, and are subject to change without notice.
w w w . a d c . c o m
•
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
11
Download from Www.Somanuals.com. All Manuals Search And Download.
SignalOn® Series
RF Signal Management
Actives: Power Supply Modules
Power Supply
(front view)
O rd e r i n g I n f o r m a t i o n
Description
Catalog Number
Power Supply Modules
AC to DC
N-MVUVAC
N-MV48DC
DC to DC
Specifications
PeRFoRMANCe ATTRiBUTe
input voltage
efficiency
AC-DC
DC-DC
90-264 Vac, 50/60 Hz
75% nominal
36-72 Vdc nominal
80% nominal
output voltage
output power
Amplifiers supported
Redundancy
24 Vdc ± 5%
24 Vdc ± 5%
200W (24 Vdc @ 8.33 Amps)
Up to nine 30 dB amplifiers
Yes, dual load sharing
0 - 50° C
192W (24 Vdc @ 8 Amps)
Up to nine 30 dB amplifiers
Yes, dual load sharing
0 - 50° C
operating temperature
Dimensions
8.55"H x 1.67"W x 12.96"D
gold-on-gold, slide-on contacts
24 Vdc output test points
Field replaceable unit
Fan fail, output power fail
8.55"H x 1.67"W x 12.96"D
gold-on-gold, slide-on contacts
24 Vdc output test points
Field replaceable unit
Fan fail, output power fail
Power connector
Test points
Fan
Alarm relays
Remote inhibit, input power
fail, output power fail
Remote inhibit, input power
fail, output power fail
TTL contacts
NeBS
Meets NEBS Level 3
Meets NEBS Level 3
w w w . a d c . c o m
•
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
12
Download from Www.Somanuals.com. All Manuals Search And Download.
SignalOn® Series
RF Signal Management
Actives: RF Switch Modules
The ADC SignalOn® RF Switch Module (RFSM) is designed for use with the
SignalOn 8-position, or 20-position powered chassis. All RF connections to the
switch are made through standard 75 W BNC, or F connectors on the rear of the
module. All operating controls and indicators are located on the front panel with
configuration controls located on the rear of the module.
The primary function of the module is to monitor the RF signal gain of the operating
primary “A“ input, and switch to the backup “B“ input if the gain of the primary
path rises, or falls below the pre-set customer selected threshold. Should the “A“
input side go above, or fall below the threshold of the unit, the RFSM will rapidly
switch the input from the failed input to the secondary input. This switch usually
is less that 10 milliseconds. Switch status, failure LEDS, and RF level bar graphs are
mounted on the front panel of the switch module. Switching threshold: +/- 3 dB or
+/- 6 dB, and alarm contact closures are located on the rear of module.
Dual RF Switch
Module
Features
• Continuous monitoring of primary and secondary
• Detects both high and low power failures
• Easily configured for redundancy or A-B
switch applications
• Front panel bar graph display provides indication
• User-selectable switching threshold:
+/- 3 dB or +/- 6 dB
of RF power and switching threshold
• Indication of switch status provided by front
• Fail-over switching time < 10 ms
panel LED and rear terminal block contacts
• Automatic switchback after "A" path is restored
• Easily configured switching threshold levels via
• Front-panel LED status and dual power
rear DIP switch
level displays
• One-step calibration
• Alarm contact for remote failure monitoring
• Available in BNC and F-connector configurations
• Single or dual modules
• Auto switch-back feature to primary input
• Built-in delay to prevent from false switching
• Automatic or manual modes of operation
• NEBS Level 3 compliant
O rd e r i n g I n f o r m a t i o n
Description
Catalog Number
Redundant RF Switch Modules
BNC connector
Single circuit
N-MRFSM1-B
N-MRFSM2-B
N-MRFSM1-F
N-MRFSM2-F
Dual circuit
Single circuit
Dual circuit
F connector
w w w . a d c . c o m
•
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
13
Download from Www.Somanuals.com. All Manuals Search And Download.
SignalOn® Series
RF Signal Management
Actives: Reverse Path Amplifier Modules
ADC’s Return Path Amplifier was designed
specifically to solve problems particular to your
environment. Providing greater density, unparalleled
cable management, greater functionality and
redundant powering, the return path amplifier
is part of the system approach to integrating all
signal management functions in a common format
and modular system.
Reverse Path Amplifier
To mount modules in SignalOn chassis use these
amplifiers in conjunction with N-ACC-BRKT-RA
(mounts 1 or 2 amps) – see page 16.
Features
• Fixed 22 dB
• Low distortion characteristics
• Low noise figure
• 5-200 MHz bandwidth
• Two 20 dB monitor ports (input and output)
• BNC or F connectors
• AC or DC powering
• Power redundancy (optional)
O rd e r i n g I n f o r m a t i o n
Description
Dimensions (H x W x D)
Catalog Number
Reverse Path Amplifier Modules
22 dB Fixed Gain
BNC connectors
57 mm x 31 mm x 203 mm
(2.25" x 1.2" x 8.0")
RFX-AMP-22B
RFX-AMP-22F
F connectors
w w w . a d c . c o m
•
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
14
Download from Www.Somanuals.com. All Manuals Search And Download.
SignalOn® Series
RF Signal Management
Accessories
O rd e r i n g I n f o r m a t i o n
Description
Catalog Number
Cable Management Kits; (includes rack mount cable management rings)
2 brackets, 2 – 2.5" x 5.5" cable rings
4 brackets, 4 – 2.5" x 5.5" cable rings
Chassis extender Brackets for;
N-ACMK-01P
N-ACMK-04P
2-position chassis, 23" rack
EB-17B
EB-35B
EB-87B
8-position chassis, 23" rack
20-position chassis, ETSI 21" rack
insertion/Withdrawal Tools
BNC insertion tool with 12" handle
BT2000-12
BT2000-24
SC-FG
BNC insertion tool with 24" handle
F connector insertion tool
Terminating Plugs
BNC terminating plug, 75 W ± 1.0%
BNC high-performance terminating plug, 75 W ± .1%
F terminating plug, 75 W ± 1.0%
BNC-TP1
BNC-TP2
CF-TP1
F high-performance terminating plug, 75 W ± .1%
Attenuator Pads
CF-TP2
XX dB pads, qty 25 (replace XX with 00 through 26)
1-5 dB pads, 5 of each pad value, total qty 25
6-10 dB pads, 5 of each pad value, total qty 25
11-15 dB pads, 5 of each pad value, total qty 25
16-20 dB pads, 5 of each pad value, total qty 25
21-25 dB pads, 5 of each pad value, total qty 25
3,6,9,12,15 dB pads, 5 of each pad value, total qty 25*
0,3,9,12,15 dB pads, 5 of each pad value, total qty 25**
75 W termination pads, qty 25
N-ACC-AP-XX
N-ACC-AP-S1
N-ACC-AP-S2
N-ACC-AP-S3
N-ACC-AP-S4
N-ACC-AP-S5
N-ACC-AP-M0
N-ACC-AP-M6
N-ACC-TP-75
* Kit intended for 0 db default MBB modules (-M0 modules)
** Kit intended for 6 db default MBB modules (-M6 modules)
BNC Terminating Plugs
F Terminating Plugs
(BNC TP-1 and TP-2)
(CF TP-1 and TP-2)
w w w . a d c . c o m
•
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
15
Download from Www.Somanuals.com. All Manuals Search And Download.
SignalOn® Series
Accessories
O rd e r i n g I n f o r m a t i o n
Description
Catalog Number
equalizer Pads
2 dB plug-in
N-ACC-LE-02
N-ACC-LE-03
N-ACC-LE-04
N-ACC-LE-05
N-ACC-LE-06
N-ACC-LE-07
N-ACC-LE-08
N-ACC-LE-09
N-ACC-LE-10
N-ACC-LE-11
N-ACC-LE-12
N-ACC-LE-13
3 dB plug-in
4 dB plug-in
5 dB plug-in
6 dB plug-in
7 dB plug-in
8 dB plug-in
9 dB plug-in
10 dB plug-in
11 dB plug-in
12 dB plug-in
13 dB plug-in
DC Power Upgrade Kits for;
2 RU chassis – used to power 8-position
5 RU chassis – used to power 20-position
Power Supply Accessories
Power cord for power supply
Fan replacement kit for power supply
Module Conversion Kits; to install
1 RF Worx® passive module into SignalOn® chassis
2 RF Worx® reverse amps into powered SignalOn® chassis
1 SignalOn® passive module into MAXNET™ chassis1
18 SignalOn® passive modules into MAXNET™ chassis1
Blank Module Covers
N-ACC-PWRKIT-08B
N-ACC-PWRKIT-20B
N-ACC-CBL-DC-DC
N-ACC-FAN
N-ACC-BRKT-RFW
N-ACC-BRKT-RA
N-AMCK-01
N-AMCK-18
Single blank panel cover
N-ACC-BLANK-01
N-ACC-BLANK-02
Dual blank panel cover
Bulkhead Testpoint Panels
Single panel with 2 F-81 bulkhead connectors
Single panel with 2 F-81 bulkhead connectors
N-MTPF2
N-MTPF6
1 MAXNET is a trademark of ATX Networks
From North America, Call Toll Free: 1-800-366-3891 • Outside of North America: +1-952-938-8080
Fax: +1-952-917-3237 • For a listing of ADC’s global sales office locations, please refer to our website.
ADC Telecommunications, Inc., P.O. Box 1101, Minneapolis, Minnesota USA 55440-1101
Specifications published here are current as of the date of publication of this document. Because we are continuously
improving our products, ADC reserves the right to change specifications without prior notice. At any time, you may
verify product specifications by contacting our headquarters office in Minneapolis. ADC Telecommunications, Inc.
views its patent portfolio as an important corporate asset and vigorously enforces its patents. Products or features
contained herein may be covered by one or more U.S. or foreign patents. An Equal Opportunity Employer
102721Ae 5/08 Revision © 2008, 2006 ADC Telecommunications, inc. All Rights Reserved
Download from Www.Somanuals.com. All Manuals Search And Download.
|