ADC Network Card SignalOn Series User Manual

SignalOn® Series  
RF Signal Management  
Advanced broadband services are being developed and launched at an ever-accelerating  
pace. While these services vary, they have one thing in common. Whether it be high-speed  
data, video-on-demand, or IP telephony, broadband subscribers expect a reliable, high-quality  
experience at an affordable price.  
ADCs SignalOn® Series has been designed with these demanding service requirements in mind.  
This next generation RF signal management platform provides unmatched density, RF performance,  
and reliability—all at a competitive price. With its patented hitless “make-before-break” attenuator  
circuit design, maintaining your RF signal network has never been easier.  
w w w . a d c . c o m  
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0  
1 - 8 0 0 - 3 6 6 - 3 8 9 1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SignalOn® Series  
RF Signal Management  
Chassis  
20-Position, 5 RU Chassis  
32-Position, 4 RU Drawer  
8-Position, 2 RU Chassis  
4-Position, 1 RU Chassis  
Catalog Number  
N - C __ __ __ __ B  
Type  
Power Kit  
32D 32-position, Drawer  
20V 20-position, Vertical  
08H 8-position, Horizontal  
04H 4-position, Horizontal  
02H 2-position, Horizontal  
N
Y
No  
Yes*  
* 20 and 8-position only  
2-Position, 1 RU Chassis  
O rd e r i n g I n f o r m a t i o n  
Description  
Catalog Number  
Passive Chassis  
32-position high-density chassis, 4 RU, black  
20-position chassis, 5 RU, black  
20-position chassis, 5 RU, NEBS  
8-position chassis, 2 RU, black  
8-position reversible chassis, 2 RU, black  
4-position chassis, 1 RU, black  
2-position chassis, 1 RU, black  
Active Chassis  
N-C32DNB  
N-C20VNB  
N-C20VN-NEBS  
N-C08HNB  
N-C08HNB-R  
N-C04HNB  
N-C02HNB  
20-position powered chassis, 5 RU, black  
20-position powered chassis, 5 RU, NEBS  
8-position powered chassis, 2 RU, black  
N-C20VYB  
N-C20VY-NEBS  
N-C08HYB  
w w w . a d c . c o m  
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0  
1 - 8 0 0 - 3 6 6 - 3 8 9 1  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
SignalOn® Series  
RF Signal Management  
Passives: Introduction  
The SignalOn® Series, combined with the  
innovative cable management of the chassis,  
provides engineers with a variety of products to  
simplify the RF signal management challenge.  
Passives:  
RF Splitter/Combiner Modules  
5 MHz to 1 GHz  
Plain Splitter/Combiner Pad and Monitor Module  
Module  
with Make-Before-Break  
Attenuation  
Catalog Number  
Features  
N - M __ __ __ __ __ __  
Industry's highest density with standard F  
and BNC connectors  
Module Type  
Make-Before-Break  
Attenuation**  
Industry's best performance and specifications  
P
C
S
Plain splitter/  
combiner  
Individual performance certificate shipped  
M0 0 dB default  
M6 6 dB default  
with every module  
Combiner with  
pad/monitor  
Patented make-before-break attenuator pad  
design for hitless signal balancing  
Configuration  
Splitter with pad/  
monitor  
Chassis supports both passive and active  
modules  
12  
14  
18  
2:1  
4:1  
8:1  
X
Splitter and  
Clear chassis door provides protection and  
combiner with  
pad/monitor (2 x  
4:1 module only)  
clear view of modules  
Clear attenuator pad covers and patented  
32 3 x 2:1*  
24 2 x 4:1*  
pad guides for simplified maintenance  
• High quality, precision F or BNC connectors  
Connector Type  
• Designed to exceed NEBS requirements for  
F
F
grounding/bonding  
B
BNC  
• Independent EMI near and far-field testing  
Ten year warranty on all passive modules  
• Available in 1 RU, 2 RU, 4 RU and 5 RU chassis  
• NEBS Level 3 compliant  
*3 x 2:1 and 2 x 4:1 housed in a single module.  
**Leave last two digits blank for plain modules.  
Selection of default pad option for pand and monitor modules  
The make before break attenuation feature requires that a default attenuation padding value be chosen  
for the module. The two options are:  
M0 – 0 dB loss on the splitter or combiner leg when attenuator pad is removed  
The M0 option is used in systems where the attenuator pad values will range from 0 dB to 10 dB.  
M6 – 6 dB loss on the splitter or combiner leg when attenuator pad is removed  
The M6 option is typically used in systems where the attenuator pad values range from 10 dB to  
25 dB. In this situation, the additional 6 dB of loss that is placed in line when the pad is removed  
will help to limit overdriving active devices further downstream and will help limit transmitter laser  
clipping, and overdriving of RF amplifiers in the distribution plant.  
w w w . a d c . c o m  
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0  
1 - 8 0 0 - 3 6 6 - 3 8 9 1  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
SignalOn® Series  
RF Signal Management  
O rd e r i n g I n f o r m a t i o n  
Description  
Catalog Number  
Plain Splitter/Combiner Modules  
BNC connector  
2:1 plain  
N-MPB12  
4:1 plain  
N-MPB14  
8:1 plain  
N-MPB18  
3 x 2:1 plain  
2 x 4:1 plain  
2:1 plain  
N-MPB32  
N-MPB24  
F connector  
N-MPF12  
4:1 plain  
N-MPF14  
8:1 plain  
N-MPF18  
3 x 2:1 plain  
2 x 4:1 plain  
0 dB default  
N-MPF32  
N-MPF24  
BNC connector  
2:1 combiner with monitor  
2:1 splitter with monitor  
N-MCB12M0  
N-MSB12M0  
N-MCB24M0  
N-MSB24M0  
N-MXB24M0  
N-MCB32M0  
N-MSB32M0  
N-MCB14M0  
N-MSB14M0  
N-MCB18M0  
N-MSB18M0  
N-MCB12M6  
N-MSB12M6  
N-MCB24M6  
N-MSB24M6  
N-MXB24M6  
N-MCB32M6  
N-MSB32M6  
N-MCB14M6  
N-MSB14M6  
N-MCB18M6  
N-MSB18M6  
2x4:1 combiner with monitor  
2x4:1 splitter with monitor  
2x4:1 splitter/combiner with monitor  
3x2:1 combiner with monitor  
3x2:1 splitter with monitor  
4:1 combiner with monitor  
4:1 splitter with monitor  
8:1 combiner with monitor  
8:1 splitter with monitor  
6 dB default  
2:1 combiner with monitor  
2:1 splitter with monitor  
2x4:1 combiner with monitor  
2x4:1 splitter with monitor  
2x4:1 splitter/combiner with monitor  
3x2:1 combiner with monitor  
3x2:1 splitter with monitor  
4:1 combiner with monitor  
4:1 splitter with monitor  
8:1 combiner with monitor  
8:1 splitter with monitor  
w w w . a d c . c o m  
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0  
1 - 8 0 0 - 3 6 6 - 3 8 9 1  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
SignalOn® Series  
RF Signal Management  
O rd e r i n g I n f o r m a t i o n  
Description  
Catalog Number  
Splitter/Combiner with Pad and Monitor Modules  
F connector  
0 dB default  
2:1 combiner with monitor  
2:1 splitter with monitor  
N-MCF12M0  
N-MSF12M0  
N-MCF24M0  
N-MSF24M0  
N-MXF24M0  
N-MCF32M0  
N-MSF32M0  
N-MCF14M0  
N-MSF14M0  
N-MCF18M0  
N-MSF18M0  
N-MCF12M6  
N-MSF12M6  
N-MCF24M6  
N-MSF24M6  
N-MXF24M6  
N-MCF32M6  
N-MSF32M6  
N-MCF14M6  
N-MSF14M6  
N-MCF18M6  
N-MSF18M6  
2x4:1 combiner with monitor  
2x4:1 splitter with monitor  
2x4:1 splitter/combiner with monitor  
3x2:1 combiner with monitor  
3x2:1 splitter with monitor  
4:1 combiner with monitor  
4:1 splitter with monitor  
8:1 combiner with monitor  
8:1 splitter with monitor  
6 dB default  
2:1 combiner with monitor  
2:1 splitter with monitor  
2x4:1 combiner with monitor  
2x4:1 splitter with monitor  
2x4:1 splitter/combiner with monitor  
3x2:1 combiner with monitor  
3x2:1 splitter with monitor  
4:1 combiner with monitor  
4:1 splitter with monitor  
8:1 combiner with monitor  
8:1 splitter with monitor  
w w w . a d c . c o m  
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0  
1 - 8 0 0 - 3 6 6 - 3 8 9 1  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
SignalOn® Series  
RF Signal Management  
Passives:  
Directional Coupler Modules  
5 MHz to 1 GHz  
Catalog Number  
N - MD __ __ __ __ __  
Connector Type  
Application Type  
Rear narrowcast signal port  
F
F
R
B
BNC  
DC Value  
Circuit Quantity  
09  
12  
20  
9 dB  
Directional Coupler  
1
Single circuit  
Triple circuit  
12 dB  
20 dB  
3
V12 12 dB variable  
O rd e r i n g I n f o r m a t i o n  
Description  
Catalog Number  
Directional Coupler Modules  
BNC connector  
9 dB  
Triple circuit  
Single circuit  
Triple circuit  
6x variable  
N-MDB309R  
N-MDB112R  
N-MDB312R  
N-MDB6V12R  
N-MDB120R  
N-MDB320R  
N-MDF309R  
N-MDF112R  
N-MDF312R  
N-MDF6V12R  
N-MDF120R  
N-MDF320R  
12 dB  
20 dB  
Single circuit  
Triple circuit  
Triple circuit  
Single circuit  
Triple circuit  
6x variable  
F connector  
9 dB  
12 dB  
20 dB  
Single circuit  
Triple circuit  
w w w . a d c . c o m  
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0  
1 - 8 0 0 - 3 6 6 - 3 8 9 1  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
SignalOn® Series  
RF Signal Management  
Passives: Conditioning and Monitor Modules  
Features  
Typically placed at the input to the forward  
path optical transmitter, this module allows  
for conditioning and grooming of the RF  
signal gain and slope. It is designed as 1:1  
input to output with two MBB circuits in  
series for pad and EQ placement.  
• -20 dB front facing monitor port  
• NEBS Level 3 compliant  
Triple C & M  
F-Connectors  
O rd e r i n g I n f o r m a t i o n  
Description  
Catalog Number  
Conditioning and Monitor Modules; triple circuit, 20 dB, 0 dB default  
BNC connector  
N-MMB320FM0  
N-MMF320FM0  
F connector  
Attenuation  
Pad  
Equalization  
(EQ) Pad  
In  
Out  
-20 dB  
(monitor)  
Conditioning and monitor module schematic  
w w w . a d c . c o m  
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0  
1 - 8 0 0 - 3 6 6 - 3 8 9 1  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
SignalOn® Series  
RF Signal Management  
Passives: L-Band Satellite Splitter Modules  
950 MHz to 2.15 GHz  
ADCs new L-Band series satellite splitter modules are engineered for the highest performance in  
the 950 MHz to 2.15 GHz frequency range. These plain splitter/combiner modules feature dual port  
power-passing capability for powering LNBs. All L-Band modules are available with precision F  
or BNC connectors, and are NEBS Level 3 compliant.  
Catalog Number  
N - ML __ __ __  
Connector Type  
Configuration  
F
F
12  
14  
18  
2:1  
4:1  
8:1  
B
BNC  
32 3 x 2:1*  
24 2 x 4:1*  
*Housed in a single module.  
L-Band  
Satellite Splitter  
O rd e r i n g I n f o r m a t i o n  
Description  
L-Band Satellite Splitter Modules  
Catalog Number  
BNC connector  
2:1 splitter  
N-MLB12  
N-MLB14  
N-MLB18  
N-MLB32  
N-MLB24  
N-MLF12  
N-MLF14  
N-MLF18  
N-MLF32  
N-MLF24  
4:1 splitter  
8:1 splitter  
3x2:1 splitter  
2x4:1 splitter  
2:1 splitter  
4:1 splitter  
8:1 splitter  
3x2:1 splitter  
2x4:1 splitter  
F connector  
All L-Band modules feature dual port power passing capability.  
Pass  
Pass  
1
2
3
4
1
2
Pass  
Pass  
Pass  
2-Way Splitter  
4-Way Splitter  
1
2
3
4
5
6
7
8
Pass  
8-Way Splitter  
w w w . a d c . c o m  
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0  
1 - 8 0 0 - 3 6 6 - 3 8 9 1  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
SignalOn® Series  
RF Signal Management  
Actives: Introduction  
Todays broadband services require high-quality  
headend infrastructure that offers excellent  
performance, reliability and design flexibility.  
Furthermore, your infrastructure solution should  
maximize the uptime of carrier-class services like  
VoIP, VOD and HSD as applications evolve and  
your network changes.  
Leveraging over a decade of RF amplifier design  
experience, ADCs SignalOn® amplifiers have been  
engineered to meet these demanding service  
requirements. Featuring operation from 50 MHz to  
1 GHz, the amplifiers offer excellent performance  
and reliability. SignalOn amplifiers and associated  
power supplies can be housed in the same chassis  
as the SignalOn passive products for increased  
design flexibility. With its electronically variable gain  
and slope controls, you can adjust signal levels in  
your network with no service downtime.  
Amplifier  
(front view)  
SignalOn amplifiers feature non-service-affecting  
gain and slope controls. This capability along with  
the patented make-before-break attenuator pad  
design of the splitters and combiners, allow for  
"hitless" RF signal adjustment—critical for today's  
carrier-class broadband service applications.  
20-Position, 5 RU Powered Chassis  
(with mixture of passive  
and active modules)  
Features  
• Operation from 50 MHz to 1 GHz  
• GaAs technology with near-100% surface  
mount design for high performance  
20-Position, 5 RU Powered Chassis  
(rear view)  
• Meets MIL-202 specs for quality and reliability  
Mounts in same SignalOn chassis as passive  
modules for maximum design flexibility  
Digitally variable gain and slope control for  
non-service-affecting signal level adjustments  
• 20 dB monitor points on both input and  
output signals for testing and troubleshooting  
8-Position, 2 RU Powered Chassis  
• "Blind-mate" power bus connector with  
(front view)  
gold-on-gold contacts; requires no cabling  
Chassis-mounted AC-DC and DC-DC power  
supply options  
Redundant powering with dual load shared  
power supplies for increased availability  
• External +24 Vdc powering option  
• NEBS Level 3 compliant  
8-Position, 2 RU Powered Chassis  
(rear view)  
w w w . a d c . c o m  
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0  
1 - 8 0 0 - 3 6 6 - 3 8 9 1  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SignalOn® Series  
Actives: Forward Path Amplifier  
Actives: Amplifier Modules  
Amplifier  
(front view)  
O rd e r i n g I n f o r m a t i o n  
Description  
Catalog Number  
Forward Path Amplifier Modules  
BNC connector  
20 dB  
30 dB  
20 dB  
30 dB  
N-MAB20FA  
N-MAB30FA  
N-MAF20FA  
N-MAF30FA  
F connector  
PeRFoRMANCe ATTRiBUTe  
Bandwidth  
20 dB Forward Amplifier  
50-1000 MHz  
30 dB Forward Amplifier  
50-1000 MHz  
optimum RF input  
Minimum full gain  
Gain adjustment range  
Tilt adjustment range  
+20 dBmV per channel  
20.0 dB  
+10 dBmV per channel  
30.0 dB  
10 +/-1 dB in 0.5 dB steps  
10 +/-1 dB in 0.5 dB steps  
10 +/-1 dB @ 50 MHz in 0.5 dB steps  
10 +/-1 dB @ 50 MHz in 0.5 dB steps  
+/- 0.4 dB from 50 to 870 MHz  
+/- 0.5 dB from 870 to 1000 MHz  
+/- 0.45 dB from 50 to 870 MHz  
+/- 0.65 dB from 870 to 1000 MHz  
Gain flatness  
Return loss,  
input and output ports  
-19.0 dB from 50 to 870 MHz  
-16.5 dB from 870 to 1000 MHz  
-18.0 dB from 50 to 870 MHz  
-15.0 dB from 870 to 1000 MHz  
7.3 dB from 50 to 870 MHz  
7.6 dB from 870 to 1000 MHz  
5.7 dB from 50 to 870 MHz  
6.2 dB from 870 to 1000 MHz  
Noise figure  
CTB1  
-73.1 dB  
-81.7 dB  
-78.2 dB  
-78.9 dB  
-84.5 dB  
-83.7 dB  
CSo1  
iMD1  
Monitor ports  
Power dissipation  
operating temperature  
Dimensions  
-20 dB test point for both RF input and RF output  
17W max  
0 - 50 degrees C  
8.55"H x 1.67"W x 7.81"D  
gold-on-gold, slide-on contacts  
Meets MIL-STD-202 Method 107  
Meets GR-63-Core Section 5.4.2  
Meets MIL-STD-202 Method 213  
Meets MIL-STD-202 Method 108  
Meets NEBS Level 3  
Power connector  
Thermal shock  
office vibration  
Mechanical shock  
Accelerated aging  
NeBS  
Note: Measured with 110 channel loading and optimum RF input level at full gain and no tilt. Specifications are typical  
worst-case numbers across the given frequency range, unless otherwise noted, and are subject to change without notice.  
w w w . a d c . c o m  
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0  
1 - 8 0 0 - 3 6 6 - 3 8 9 1  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SignalOn® Series  
RF Signal Management  
Actives: Power Supply Modules  
Power Supply  
(front view)  
O rd e r i n g I n f o r m a t i o n  
Description  
Catalog Number  
Power Supply Modules  
AC to DC  
N-MVUVAC  
N-MV48DC  
DC to DC  
Specifications  
PeRFoRMANCe ATTRiBUTe  
input voltage  
efficiency  
AC-DC  
DC-DC  
90-264 Vac, 50/60 Hz  
75% nominal  
36-72 Vdc nominal  
80% nominal  
output voltage  
output power  
Amplifiers supported  
Redundancy  
24 Vdc ± 5%  
24 Vdc ± 5%  
200W (24 Vdc @ 8.33 Amps)  
Up to nine 30 dB amplifiers  
Yes, dual load sharing  
0 - 50° C  
192W (24 Vdc @ 8 Amps)  
Up to nine 30 dB amplifiers  
Yes, dual load sharing  
0 - 50° C  
operating temperature  
Dimensions  
8.55"H x 1.67"W x 12.96"D  
gold-on-gold, slide-on contacts  
24 Vdc output test points  
Field replaceable unit  
Fan fail, output power fail  
8.55"H x 1.67"W x 12.96"D  
gold-on-gold, slide-on contacts  
24 Vdc output test points  
Field replaceable unit  
Fan fail, output power fail  
Power connector  
Test points  
Fan  
Alarm relays  
Remote inhibit, input power  
fail, output power fail  
Remote inhibit, input power  
fail, output power fail  
TTL contacts  
NeBS  
Meets NEBS Level 3  
Meets NEBS Level 3  
w w w . a d c . c o m  
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0  
1 - 8 0 0 - 3 6 6 - 3 8 9 1  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SignalOn® Series  
RF Signal Management  
Actives: RF Switch Modules  
The ADC SignalOn® RF Switch Module (RFSM) is designed for use with the  
SignalOn 8-position, or 20-position powered chassis. All RF connections to the  
switch are made through standard 75 W BNC, or F connectors on the rear of the  
module. All operating controls and indicators are located on the front panel with  
configuration controls located on the rear of the module.  
The primary function of the module is to monitor the RF signal gain of the operating  
primary “A“ input, and switch to the backup “B“ input if the gain of the primary  
path rises, or falls below the pre-set customer selected threshold. Should the “A“  
input side go above, or fall below the threshold of the unit, the RFSM will rapidly  
switch the input from the failed input to the secondary input. This switch usually  
is less that 10 milliseconds. Switch status, failure LEDS, and RF level bar graphs are  
mounted on the front panel of the switch module. Switching threshold: +/- 3 dB or  
+/- 6 dB, and alarm contact closures are located on the rear of module.  
Dual RF Switch  
Module  
Features  
Continuous monitoring of primary and secondary  
Detects both high and low power failures  
• Easily configured for redundancy or A-B  
switch applications  
Front panel bar graph display provides indication  
• User-selectable switching threshold:  
+/- 3 dB or +/- 6 dB  
of RF power and switching threshold  
Indication of switch status provided by front  
• Fail-over switching time < 10 ms  
panel LED and rear terminal block contacts  
Automatic switchback after "A" path is restored  
• Easily configured switching threshold levels via  
• Front-panel LED status and dual power  
rear DIP switch  
level displays  
One-step calibration  
Alarm contact for remote failure monitoring  
• Available in BNC and F-connector configurations  
Single or dual modules  
Auto switch-back feature to primary input  
• Built-in delay to prevent from false switching  
Automatic or manual modes of operation  
• NEBS Level 3 compliant  
O rd e r i n g I n f o r m a t i o n  
Description  
Catalog Number  
Redundant RF Switch Modules  
BNC connector  
Single circuit  
N-MRFSM1-B  
N-MRFSM2-B  
N-MRFSM1-F  
N-MRFSM2-F  
Dual circuit  
Single circuit  
Dual circuit  
F connector  
w w w . a d c . c o m  
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0  
1 - 8 0 0 - 3 6 6 - 3 8 9 1  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SignalOn® Series  
RF Signal Management  
Actives: Reverse Path Amplifier Modules  
ADCs Return Path Amplifier was designed  
specifically to solve problems particular to your  
environment. Providing greater density, unparalleled  
cable management, greater functionality and  
redundant powering, the return path amplifier  
is part of the system approach to integrating all  
signal management functions in a common format  
and modular system.  
Reverse Path Amplifier  
To mount modules in SignalOn chassis use these  
amplifiers in conjunction with N-ACC-BRKT-RA  
(mounts 1 or 2 amps) – see page 16.  
Features  
• Fixed 22 dB  
• Low distortion characteristics  
• Low noise figure  
• 5-200 MHz bandwidth  
Two 20 dB monitor ports (input and output)  
• BNC or F connectors  
AC or DC powering  
• Power redundancy (optional)  
O rd e r i n g I n f o r m a t i o n  
Description  
Dimensions (H x W x D)  
Catalog Number  
Reverse Path Amplifier Modules  
22 dB Fixed Gain  
BNC connectors  
57 mm x 31 mm x 203 mm  
(2.25" x 1.2" x 8.0")  
RFX-AMP-22B  
RFX-AMP-22F  
F connectors  
w w w . a d c . c o m  
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0  
1 - 8 0 0 - 3 6 6 - 3 8 9 1  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SignalOn® Series  
RF Signal Management  
Accessories  
O rd e r i n g I n f o r m a t i o n  
Description  
Catalog Number  
Cable Management Kits; (includes rack mount cable management rings)  
2 brackets, 2 – 2.5" x 5.5" cable rings  
4 brackets, 4 – 2.5" x 5.5" cable rings  
Chassis extender Brackets for;  
N-ACMK-01P  
N-ACMK-04P  
2-position chassis, 23" rack  
EB-17B  
EB-35B  
EB-87B  
8-position chassis, 23" rack  
20-position chassis, ETSI 21" rack  
insertion/Withdrawal Tools  
BNC insertion tool with 12" handle  
BT2000-12  
BT2000-24  
SC-FG  
BNC insertion tool with 24" handle  
F connector insertion tool  
Terminating Plugs  
BNC terminating plug, 75 W ± 1.0%  
BNC high-performance terminating plug, 75 W ± .1%  
F terminating plug, 75 W ± 1.0%  
BNC-TP1  
BNC-TP2  
CF-TP1  
F high-performance terminating plug, 75 W ± .1%  
Attenuator Pads  
CF-TP2  
XX dB pads, qty 25 (replace XX with 00 through 26)  
1-5 dB pads, 5 of each pad value, total qty 25  
6-10 dB pads, 5 of each pad value, total qty 25  
11-15 dB pads, 5 of each pad value, total qty 25  
16-20 dB pads, 5 of each pad value, total qty 25  
21-25 dB pads, 5 of each pad value, total qty 25  
3,6,9,12,15 dB pads, 5 of each pad value, total qty 25*  
0,3,9,12,15 dB pads, 5 of each pad value, total qty 25**  
75 W termination pads, qty 25  
N-ACC-AP-XX  
N-ACC-AP-S1  
N-ACC-AP-S2  
N-ACC-AP-S3  
N-ACC-AP-S4  
N-ACC-AP-S5  
N-ACC-AP-M0  
N-ACC-AP-M6  
N-ACC-TP-75  
* Kit intended for 0 db default MBB modules (-M0 modules)  
** Kit intended for 6 db default MBB modules (-M6 modules)  
BNC Terminating Plugs  
F Terminating Plugs  
(BNC TP-1 and TP-2)  
(CF TP-1 and TP-2)  
w w w . a d c . c o m  
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0  
1 - 8 0 0 - 3 6 6 - 3 8 9 1  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SignalOn® Series  
Accessories  
O rd e r i n g I n f o r m a t i o n  
Description  
Catalog Number  
equalizer Pads  
2 dB plug-in  
N-ACC-LE-02  
N-ACC-LE-03  
N-ACC-LE-04  
N-ACC-LE-05  
N-ACC-LE-06  
N-ACC-LE-07  
N-ACC-LE-08  
N-ACC-LE-09  
N-ACC-LE-10  
N-ACC-LE-11  
N-ACC-LE-12  
N-ACC-LE-13  
3 dB plug-in  
4 dB plug-in  
5 dB plug-in  
6 dB plug-in  
7 dB plug-in  
8 dB plug-in  
9 dB plug-in  
10 dB plug-in  
11 dB plug-in  
12 dB plug-in  
13 dB plug-in  
DC Power Upgrade Kits for;  
2 RU chassis – used to power 8-position  
5 RU chassis – used to power 20-position  
Power Supply Accessories  
Power cord for power supply  
Fan replacement kit for power supply  
Module Conversion Kits; to install  
1 RF Worx® passive module into SignalOn® chassis  
2 RF Worx® reverse amps into powered SignalOn® chassis  
1 SignalOn® passive module into MAXNETchassis1  
18 SignalOn® passive modules into MAXNETchassis1  
Blank Module Covers  
N-ACC-PWRKIT-08B  
N-ACC-PWRKIT-20B  
N-ACC-CBL-DC-DC  
N-ACC-FAN  
N-ACC-BRKT-RFW  
N-ACC-BRKT-RA  
N-AMCK-01  
N-AMCK-18  
Single blank panel cover  
N-ACC-BLANK-01  
N-ACC-BLANK-02  
Dual blank panel cover  
Bulkhead Testpoint Panels  
Single panel with 2 F-81 bulkhead connectors  
Single panel with 2 F-81 bulkhead connectors  
N-MTPF2  
N-MTPF6  
1 MAXNET is a trademark of ATX Networks  
From North America, Call Toll Free: 1-800-366-3891 • Outside of North America: +1-952-938-8080  
Fax: +1-952-917-3237 • For a listing of ADC’s global sales office locations, please refer to our website.  
ADC Telecommunications, Inc., P.O. Box 1101, Minneapolis, Minnesota USA 55440-1101  
Specifications published here are current as of the date of publication of this document. Because we are continuously  
improving our products, ADC reserves the right to change specifications without prior notice. At any time, you may  
verify product specifications by contacting our headquarters office in Minneapolis. ADC Telecommunications, Inc.  
views its patent portfolio as an important corporate asset and vigorously enforces its patents. Products or features  
contained herein may be covered by one or more U.S. or foreign patents. An Equal Opportunity Employer  
102721Ae 5/08 Revision © 2008, 2006 ADC Telecommunications, inc. All Rights Reserved  
Download from Www.Somanuals.com. All Manuals Search And Download.  

3Com Two Way Radio 1640SU User Manual
Alcatel Carrier Internetworking Solutions Modem 350I User Manual
AllerAir Air Cleaner 4000 D AH User Manual
American DJ DJ Equipment Galactic Star User Manual
American Dryer Clothes Dryer GX1 M User Manual
Atlas Saw 447299 User Manual
Audiovox Car Satellite Radio System 128 7902A User Manual
Avital Remote Starter 4111 User Manual
Barco Network Router 3G HD SD SD User Manual
Beko Refrigerator CF5533APB User Manual