AD Blood Pressure Monitor UA 767 Plus BT User Manual

Digital Blood Pressure Monitor  
Model UA-767 BT  
Instruction Manual  
1WMPD4001357A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Contents  
Dear Customers....................................................................2  
Preliminary Remarks.............................................................2  
Precautions...........................................................................2  
Parts Identification................................................................3  
Symbols................................................................................4  
Using The Monitor................................................................5  
Installing / Changing The Batteries ..................................5  
Connecting The Air Hose .................................................5  
Attaching The Arm Cuff ...................................................6  
How To Take Proper Measurements ...................................6  
Measurement...................................................................6  
After Measurement ..........................................................6  
Measurements......................................................................7  
Normal Measurement.......................................................7  
Measurement With The Desired Systolic Pressure .............8  
Notes For Proper Measurement ........................................8  
What Is An Irregular Heartbeat..............................................9  
Pressure Bar Indicator...........................................................9  
How The Wireless Connection Works.....................................9  
About Blood Pressure..........................................................10  
What Is Blood Pressure? .................................................10  
What Is Hypertension And How Is It Controlled? .............10  
Why Measure Blood Pressure At Home? ..........................10  
WHO Blood Pressure Classification.................................10  
Blood Pressure Variations...............................................10  
Troubleshooting.................................................................11  
Maintenance.......................................................................12  
Technical Data....................................................................12  
English 1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Dear Customers  
Congratulations on purchasing a state-of-the-art A&D blood pressure  
monitor, one of the most advanced monitors available today. Designed  
for ease of use and accuracy, this monitor will facilitate your daily blood  
pressure regimen.  
We recommend that you read through this manual carefully before  
using the device for the first time.  
Preliminary Remarks  
This device conforms to the European Directive 93/42 EEC for Medical  
Products. This is made evident by the  
mark of conformity.  
(0366: The reference number to the involved notified body)  
The device complies with the statutory EMC (Electromagnetic  
Compatibility) directive 89/336/EEC. The WML-40AH is approved in  
accordance to R&TTE directive transmitter module marked by  
,
manufactured by MITSUMI incorporated to OEM product.  
The device complies with part 15 of the FCC rules and contains the FCC  
ID POOWML-C40.  
The device is designed for use on adults only, not newborns or infants.  
Environment for use  
The device is for use indoors.  
Precautions  
Precision components are used in the construction of this device.  
Extremes in temperature, humidity, direct sunlight, shock or dust should  
be avoided.  
Clean the device with a soft, dry cloth. Never use thinner, alcohol,  
benzine, or wet cloth.  
Avoid tightly folding the cuff or storing the hose tightly twisted for long  
periods, as such treatment may shorten the life of the components.  
The device and cuff are not water resistant. Prevent rain, sweat and  
water from soiling the device and cuff.  
Measurements may be distorted if the device is used close to televisions,  
microwave ovens, cellular telephones, X-ray or other devices with strong  
electrical fields.  
Used equipment, parts and batteries are not treated as ordinary  
household waste, and must be disposed of according to the applicable  
local regulations.  
English 2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Parts Identification  
DC Jack  
START Button  
Display  
Air Connector Plug  
Air Socket  
Arm Cuff  
Air Hose  
Proper Fit Range  
Index Mark  
Battery Cover  
Battery Compartment  
1.5V Batteries  
(R6P or AA)  
MEMORY  
Systolic Pressure  
Diastolic Pressure  
Part of Display  
Pressure Bar Indicator  
Pulse Rate  
Battery Indicator  
Heart Mark  
I.H.B. Indicator (Irregular heartbeat indicator)  
English 3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Symbols  
Function / Meaning  
Standby and power on.  
Symbols  
Recommended Action  
Battery installation guide  
Direct current  
SN  
Serial number  
Date of manufacture  
Type BF: Device, cuff and tubing are  
designed to provide special protection  
against electrical shocks.  
Measurement is in  
progress. Remain as still  
as possible.  
The indicator that appears while  
measurement is in progress. It blinks  
when the pulse is detected.  
Irregular Heartbeat indicator. (I.H.B.)  
The indicator that appears when an  
irregular heartbeat or any excessive  
body movement is detected during  
the measurement.  
Previous measurements stored in  
MEMORY.  
The battery power indicator during the  
measurement.  
Full Battery  
Replace all batteries with  
new ones, when the  
indicator blinks.  
The indicator blinks when battery  
power is low.  
Low Battery  
Try the measurement  
again. Remain very still  
during the measurement.  
Unstable blood pressure due to  
movement during the measurement.  
The systolic and diastolic values are  
within 10 mmHg of each other.  
The pressure value did not increase  
during inflation.  
Fasten the cuff correctly,  
and try the measurement  
again.  
The cuff is not fastened correctly.  
The pulse is not detected correctly.  
PUL. DISPLAY ERROR  
SYS  
Systolic blood pressure in mmHg  
Diastolic blood pressure in mmHg.  
Pulse per minute  
DIA  
PUL./min  
EC directive medical device label  
R&TTE directive transmitter module label  
WEEE label  
English 4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Using The Monitor  
Installing / Changing The Batteries  
1. Slide the battery cover up to open it.  
Step 1  
Step 3  
2. Remove the used batteries and insert  
new batteries into the battery  
compartment as shown, taking care that  
the polarities (+) and (-) are correct.  
Step 2  
3. Slide the battery cover down to close.  
Use only R6P, AA batteries.  
CAUTION  
Insert the batteries as shown in the battery compartment. If not, the  
device will not work.  
When  
(LOW BATTERY mark) blinks in the display, replace all batteries  
with new ones. Do not mix old and new batteries. It may shorten the  
battery life, or cause the device to malfunction.  
(LOW BATTERY mark) does not appear when the batteries are drained.  
Battery life varies with the ambient temperature and may be shorter at  
low temperatures.  
Remove the batteries if the device is not to be used for a long time.  
The batteries may leak and cause a malfunction.  
Use the specified batteries only. The batteries provided with the device  
are for testing monitor performance and may have a limited life.  
Connecting The Air Hose  
Insert the air connector plug into the air socket firmly.  
Air Hose  
Air Connector Plug  
Air Socket  
English 5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Using The Monitor  
Attaching The Arm Cuff  
Rolling up shirtsleeve  
1. Wrap the cuff around the upper  
arm, about 2 - 3 cm above the  
elbow, as shown. Place the cuff  
directly against the skin, as  
clothing may cause a faint pulse,  
and result in a measurement error.  
Cuff  
Air Hose  
2. Constriction of the upper arm,  
caused by rolling up a shirtsleeve,  
may prevent accurate readings.  
2 -3 cm  
3. Confirm that the index  
within the proper fit range.  
points  
Constriction of the Upper Arm  
How To Take Proper Measurements  
For the most accurate blood  
pressure measurement:  
Sit comfortably at a table.  
Rest your arm on the table.  
Relax for about five to ten minutes  
before measurement.  
Index  
and Proper fit range  
Place the center of the cuff at the same height as your heart.  
Remain still and keep quiet during measurement.  
Do not measure right after physical exercise or a bath. Rest for twenty or  
thirty minutes before taking the measurement.  
Try to measure your blood pressure at the same time every day.  
Measurement  
During measurement, it is normal for the cuff to feel very tight. (Do not be  
alarmed)  
After Measurement  
After measurement, press the START button to turn off the power.  
Remove the cuff and record your data.  
Note: The device has an automatic power shut-off function, which turns the  
power off approximately one minute after measurement.  
Allow at least ten minutes between measurements on the same person.  
English 6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Measurements  
BT is designed to detect the pulse and to inflate the  
Model UA-767  
cuff to a systolic pressure level automatically.  
If your systolic pressure is expected to exceed 230 mmHg or you use the  
optional small cuff, read "Measurement with the desired systolic  
pressure" on the next page.  
Normal Measurement  
1. Place the cuff on the arm (preferably the left arm).  
At heart level  
Sit quietly during measurement.  
2. Press the START button.  
START button  
The last data of systolic and diastolic  
pressure and pulse rate are displayed  
briefly. Then the display changes, as  
indicated in the figure at the right, as the  
measurement begins. The cuff starts to  
inflate. It is normal for the cuff to feel very  
tight. A pressure bar indicator is displayed,  
as in the figure at the right, during inflation.  
The last data  
at initial display  
Starts inflation  
Pressurizing  
Note: If you wish to stop inflation at any time,  
press the START button again.  
3. When inflation is complete, deflation starts  
automatically and the  
(heart mark)  
blinks, indicating that the measurement is  
in progress. Once the pulse is detected,  
the mark blinks with each pulse beat.  
Measurement  
in progress  
Note: If an appropriate pressure is not  
obtained, the device starts to inflate  
again automatically.  
Systolic pressure  
Diastolic pressure  
4. When the measurement is complete, the  
systolic and diastolic pressure readings and  
pulse rate are displayed. The cuff exhausts  
the remaining air and deflates completely.  
Pulse rate  
5. Press the START button again to turn  
off the power.  
Exhausts remaining  
air automatically  
Note: Model UA-767  
BT is provided with an automatic power  
shut-off function. Allow at least ten minutes between  
measurements on the same person.  
English 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Measurements  
Measurement With The Desired Systolic Pressure  
If your systolic pressure is expected to exceed 230 mmHg or you use the  
optional small cuff, use this procedure.  
1. Place the cuff on the arm (preferably the left arm).  
At heart level  
2. Press and hold the START button  
until a number about 30 to 40 mmHg  
higher than your expected systolic  
Press and hold the button  
Release the button  
at the desired  
systolic pressure  
pressure appears.  
3. Release the START button to start  
measurement, when the desired  
number is reached. Then continue to  
measure your blood pressure as  
described on the previous page.  
Refer to the previous page  
for measurement  
Notes For Proper Measurement  
Sit down in a comfortable position. Place the arm to be used for the  
measurement on a table or other support so that the center of the cuff  
will be at the same height as your heart.  
Relax for about five or ten minutes before taking a measurement. If you  
are excited or depressed by emotional stress, the measurement will  
reflect this stress as a higher (or lower) than normal blood pressure  
reading and the pulse reading will usually be faster than normal.  
An individual's blood pressure varies constantly, depending on what you  
are doing and what you have eaten. What you drink can have a very  
strong and rapid effect on your blood pressure.  
This device bases its measurements on the heartbeat. If you have a very  
weak or irregular heartbeat, the device may have difficulty determining  
your blood pressure.  
Should the device detect a condition that is abnormal, it will stop the  
measurement and display an error symbol. See page 4 for the  
description of symbols.  
This blood pressure monitor is intended for use by adults only. Consult  
with your physician before using this device on a child. A child should not  
use this device unattended.  
English 8  
Download from Www.Somanuals.com. All Manuals Search And Download.  
What Is An Irregular Heartbeat  
Model UA-767  
BT blood pressure monitor provides a blood  
pressure and pulse rate measurement even when an irregular heartbeat  
occurs. An irregular heartbeat is defined as a heartbeat that varies by  
25% from the average of all heartbeats during the blood pressure  
measurement. It is important that you be relaxed, remain still and do not  
talk during measurements.  
Note: We recommend contacting your physician if you see this  
indicator frequently.  
Pressure Bar Indicator  
The indicator monitors the progress of pressure during measurement.  
Pressurizing  
Releasing air  
Inflation in progress  
Measurement in progress  
Inflation complete  
How The Wireless Connection Works  
At the end of the measurement, your blood pressure will be sent  
automatically to your health monitoring device. You do not need to do  
anything. If the health monitoring device is not working or is not within  
range of the blood pressure monitor, the blood pressure will be stored in  
the blood pressure monitor's memory (up to 40 sets).  
English 9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
About Blood Pressure  
What Is Blood Pressure?  
Blood pressure is the force exerted by blood against the walls of the arteries.  
Systolic pressure occurs when the heart contracts. Diastolic pressure occurs  
when the heart expands. Blood pressure is measured in millimeters of  
mercury (mmHg). One's natural blood pressure is represented by the  
fundamental pressure, which is measured first thing in the morning while one  
is still at rest and before eating.  
What Is Hypertension And How Is It Controlled?  
Hypertension, an abnormally high arterial blood pressure, if left unattended,  
can cause many health problems including stroke and heart attack.  
Hypertension can be controlled by altering lifestyle, avoiding stress, and with  
medication under a doctor’s supervision.  
To prevent hypertension or keep it under control:  
Do not smoke  
Exercise regularly  
Reduce salt and fat intake  
Maintain proper weight  
Have regular physical checkups  
Why Measure Blood Pressure At Home?  
Blood pressure measured at a clinic or doctor's office may cause  
apprehension and can produce an elevated reading, 25 to 30 mmHg higher  
than that measured at home. Home measurement reduces the effects of  
outside influences on blood pressure readings, supplements the doctor's  
readings and provides a more accurate, complete blood pressure history.  
WHO Blood Pressure Classification  
Standards to assess high  
Reference Material: Journal of Hypertension 1999, Vol 17 No.2  
blood  
pressure,  
without  
mmHg  
110  
Grade 3 hypertension (severe)  
regard to age, have been  
established by the World  
Health Organization (WHO),  
as shown in the chart.  
Grade 2 hypertension (moderate)  
105  
100  
95  
Grade 1 hypertension (mild)  
90  
High-normal  
Normal  
85  
Blood Pressure Variations  
An individual’s blood pressure  
varies greatly on a daily and  
seasonal basis. It may vary by  
80  
Optimal  
120 130 140 150 160 170 180  
Systolic blood pressure mmHg  
30 to 50 mmHg due to various conditions during the day. In hypertensive  
individuals’ variations are even more pronounced. Normally, the blood  
pressure rises while at work or play and falls to its lowest levels during sleep.  
So, do not be overly concerned by the results of one measurement.  
Take measurements at the same time every day using the procedure  
English 10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Typical fluctuation within a day  
(Measured every five minutes)  
Systolic  
described in this manual to get to know your  
normal blood pressure. Regular readings give  
a more comprehensive blood pressure history.  
Be sure to note date and time when recording  
your blood pressure. Consult your doctor to  
interpret your blood pressure data.  
Sleep  
Time  
Diastolic  
PM  
AM  
Troubleshooting  
Problem  
Possible Reason  
Recommended Action  
Nothing appears Batteries are drained.  
in the display,  
Replace all batteries with new ones.  
Reinstall the batteries with  
even when the  
power is turned  
on.  
Battery terminals are not negative and positive terminals  
in the correct position.  
matching those indicated on the  
battery compartment.  
Battery power is low.  
(LOW BATTERY  
The cuff does  
not inflate.  
mark) blinks. [ If the  
batteries are drained  
completely, the mark  
does not appear.]  
The cuff is not fastened  
properly.  
Replace all batteries with new  
ones.  
Fasten the cuff correctly.  
You moved your arm or Make sure you remain very still  
body during the  
measurement.  
and quiet during the  
measurement.  
The unit does  
not measure.  
Readings are  
too high or too  
low.  
Sit comfortably and still.  
Raise your hand so that the cuff is  
at the same level as your heart.  
If you have a very weak or  
irregular heat beat, the device may  
have difficulty in determining your  
blood pressure.  
The cuff position is not  
correct.  
The value is different  
from that measured at a  
clinic or doctor’s office.  
See “Why measure blood  
pressure at home”.  
Other  
Remove the batteries. Place them  
back properly and try the  
measurement again.  
Note: If the actions described above do not solve the problem, contact the  
dealer. Do not attempt to open or repair this product, as any attempt to do  
so will make your warranty invalid.  
English 11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Maintenance  
Do not open the device. It uses delicate electrical components and an  
intricate air unit that could be damaged. If you cannot fix the problem  
using the troubleshooting instructions, request service from your dealer  
or from the A&D service group. The A&D service group will provide  
technical information, spare parts and units to authorized dealers.  
The device was designed and manufactured for a long service life.  
However it is generally recommended to have the monitor inspected  
every 2 years, to ensure proper functioning and accuracy. Please contact  
either your authorized dealer or A&D for maintenance.  
Technical Data  
Type  
UA-767PBT / UA-767PBT-G  
Oscillometric measurement  
Pressure: 20 - 280 mmHg  
Measurement method  
Measurement range  
Pulse:  
40 - 200 beats / minute  
Measurement accuracy  
Power supply  
Pressure: ±3 mmHg or 2%, whichever is greater  
Pulse:  
±5%  
4 x 1.5V batteries (R6P or AA)  
Upper arm circumference 22 - 32 cm (8.7" - 12.6")  
Classification  
Clinical test  
EMC  
Type BF  
According to ANSI / AAMI SP-10 1987  
IEC 60601-1-2: 2001  
Wireless communication WML-40AH (MITSUMI Electronics Co. Ltd.)  
Operating condition  
Storage condition  
Dimensions  
+10°C to +40°C / 30%RH to 85 %RH  
-10°C to +60°C / 30%RH to 85 %RH  
Approx. 147 [W] x 64 [H] x 110 [D] mm  
Approx. 300 g, excepting batteries  
Weight  
Note: Specifications are subject to change for improvement without prior notice.  
The inspection for every two years of service is only recommended for European  
customers, in order to comply with regulatory requirements. Routine inspection  
and maintenance is not needed for non-European customers.  
English 12  
Download from Www.Somanuals.com. All Manuals Search And Download.  

3M Tablet Accessory 800ab User Manual
8e6 Technologies Network Card TAR User Manual
Agilent Technologies Video Gaming Accessories E4370A User Manual
Airfree Air Cleaner Onix 3000 User Manual
Alpine CD Player CDM 7871 User Manual
ATON Stereo Receiver HDR44 User Manual
Audiovox Stereo Amplifier AMP 610 User Manual
BC Speakers Portable Speaker DE 82 User Manual
Beko Cooktop HII 63500 T User Manual
Beko Freezer DN162720DX User Manual