SAFETY INFORMATION  
The 3MBenchtop Air Ionizer 963E is designed to generate and deliver a  
stream of ionized air. Its intended use is to neutralize excess static electricity  
buildup on electronic devices and work surfaces. It is meant to function as a  
stand alone device. The Ionizer 963E is not intended to take the place of proper  
grounding of personnel as the preferred method of controlling electrostatic  
buildup and preventing hazardous discharge.  
Explanation of Signal Word Consequences  
Indicates a potentially hazardous situation, which, if not avoided, could  
:
WARNING  
result in death or serious injury and/or property damage.  
Indicates a potentially hazardous situation, which, if not avoided, may  
result in minor or moderate injury and/or property damage.  
:
CAUTION  
Indicates a potentially hazardous situation, which, if not avoided, may  
result in property damage.  
:
NOTICE  
CAUTION  
• The Ionizer 963E runs off 24VDC power, supplied by a universal power supply capable of converting  
100–240VAC electrical service. Usage of the unit with the incorrect electrical voltage could result in  
incorrect performance and an unsafe operating condition.  
• The Ionizer 963E has no user-serviceable parts. Do not remove the grill or disassemble the unit in  
any way. If service other than that recommended in this manual is needed, please contact 3M for  
information. UNAUTHORIZED SERVICE WILL VOID THE WARRANTY.  
• The Ionizer 963E is NOT designed for usage in hazardous environments where the possibility of  
explosion or fire exists.  
• When cleaning the Ionizer 963E housing or emitter points, verify that the unit is off and  
disconnected from electrical power. Collected dirt on this unit should be removed regularly to  
prevent accumulation that may result in fire.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
1.0 Description  
The 3MBenchtop Air Ionizer 963E is a self-contained ionizing air blower  
designed to remove static charges from non-conductive objects. The proprietary  
circuitry contained in the blower generates balanced levels of positive and  
negative ions. The Ionizer 963E is equipped with a two speed fan which allows  
the user to select the amount of ionized air to be delivered to the target object.  
In addition, the housing of the Ionizer 963E is constructed of a static-dissipative  
plastic, which minimizes the amount of static charge that can build up on the  
outside surface of the unit.  
2.0 Performance  
The Ionizer 963E reduces a static charge of 1000V to 100V in less than two  
seconds (the discharge time) at a distance of one foot (30 cm) using the high fan  
speed. Testing is performed in accordance with the ionization standard ANSI/  
ESD S3.1.  
3.0 Power Requirements  
The Ionizer 963E requires 24VDC power, which is supplied through a Mini  
DIN connector on the back of the unit. The Ionizer 963E is packaged with a  
switching power supply, capable of converting 100V–240VAC, 50/60 Hz into  
24VDC. The switching power supply uses a 6 ft. (1.8 m) cord to connect to the  
ionizer, and has an IEC 320 input socket for incoming power. It comes with a  
North American-style three-prong plug or Continental Europe (EURO) plug.  
Two versions are available depending on the power cord plug (European or  
North American). The Ionizer 963E should only be used with the included power  
supply.  
4.0 Installation  
4.1 The Ionizer 963E mounts easily in a variety of positions using the  
provided tilting bracket/stand. Place the unit on the work surface and  
point it at the area or object to be neutralized. Alternatively, the mounting  
bracket may be attached directly to or above the workstation, or on  
another supporting structure. Please note that placement of the Ionizer  
963E is important in determining its effectiveness. The distance from the  
target object, and fan speed affect the ionizers performance. As distance  
increases or fan speed is reduced, the discharge time will increase.  
4.2 Connect the switching power supply to the Ionizer 963E using the Mini  
DIN connector. Then, using the appropriate electrical power cord, connect  
the switching power supply to an electrical outlet.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
5.0 Operation  
The three position rocker switch on the front of the unit is the POWER switch.  
The center switch position (marked O) is the OFF position. The upper and  
lower switch positions (marked II and I) turn the unit on to HIGH and LOW fan  
speeds. Use this switch to turn the unit on and to select the desired fan speed.  
A green monitor light is also illuminated respectively on the front of the unit,  
which indicates that the power switch is in one of the ON positions, and that the  
ionizer is now in use.  
6.0 Maintenance  
Occasional cleaning of the case and of the emitter points are the only routine  
maintenance procedures required.  
6.1 Cleaning the case: Wipe the case with a soft cloth moistened with water.  
If a stronger cleaning solution is required, mild detergent or alcohol may  
be used. Do not use solvents that will attack the plastic case.  
6.2 Cleaning the emitter points: The emitter points are located between the  
fan blades and the rear grill. A jet of clean, compressed air can be used  
to remove dirt on emitter points. If a more rigorous cleaning method is  
needed to remove particulate, clean the points with a cotton swab. Access  
to the points is available through the rear grill. Be careful not to damage  
the points during cleaning.  
7.0 Performance Verification  
The 3MBenchtop Air Ionizer 963E is factory adjusted to provide optimum  
performance. Further adjustment in the field is not possible. However, the  
following instructions can be followed to determine whether the Ionizer is  
performing to specification. The testing follows the procedure outlined in the  
standard for Ionization, ANSI/ ESD STM3.1. Please refer to this standard for  
more complete information.  
7.1 Equipment Needed  
3MCharge Analyzer 711 or equivalent charge plate monitor (CPM). If  
an alternate CPM is used, please refer to its Operating Manual for details  
on how to perform the following instructions.  
7.2 Static Discharge Time  
The Ionizer 963E will reduce the charge on the 6 in. x 6 in. square  
isolated metal plate on the CPM from 1000V to 100V in less than 2  
seconds (high fan speed). The metal plate for the CPM must be located  
at a distance of one foot (30 cm) from the ionizer and centered in the air  
stream.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
7.21 Attach the flat plate electrode to the 3MCharge Analyzer 711.  
Refer to the owners manual for the Analyzer 711 for complete  
operating instructions.  
7.22 Place the Analyzer 711 on its side allowing for viewing of the  
display. Position the Analyzer 711 so that the plate is parallel to  
the ionizer at a distance of one foot. The plate of the Analyzer 711  
should be centered (up & down, left & right) in the air stream. It  
may be necessary to raise the ionizer from the surface to allow for  
centering on the Analyzer 711 charge plate. If so, use a block of  
appropriate height to elevate the Analyzer 711. Please note that the  
plate must be kept totally isolated from ground and that the edge of  
the plate should be raised up a minimum distance of 3 in. from the  
work surface. Reference ANSI/ESD-STM3.1.  
7.23 Turn on the ionizer at high speed and allow it to run for five  
minutes.  
7.24 Charge the plate positive as described in the Analyzer 711  
operating instructions for “Static Decay Time” mode. Observe the  
discharge time indicated on the Analyzer 711. Repeat this step for  
negative polarity.  
7.3 Ion Balance  
The ionized air blower will stay within an offset voltage of +/-30 volts  
(max. deviation from zero) at a distance of one foot, when measured  
using the following procedure.  
7.31 Position the ionizer and CPM as stated above in Section 7.22.  
7.32 Turn on the ionizer at high speed and allow it to run for five  
minutes.  
7.33 Use a ground wire to ground the charge plate of the Analyzer 711.  
This will remove any/all residual charge present on the charge  
plate. If the CPM does not zero, adjust the zero control.  
7.34 Remove the ground wire and observe the display on the Analyzer  
711. The voltage (either ) observed during this time is the  
“offset voltage” and is a measure of instantaneous ion imbalances  
produced by the ionizer.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
8.0 3MBenchtop Air Ionizer 963E Physical Characteristics  
Item  
Typical Property  
Power Ratings  
24VDC, 0.42A  
through included universal power transformer  
Power Inlets  
Mini DIN Socket  
Power Transformer  
Input: 100V–240VAC, 0.8A, 50/60 Hz  
into IEC320 Socket  
Output: 24VDC, 1.0A  
6 ft. (1.8m) cord with Mini DIN plug  
Dimensions  
(with mounting base)  
8.5 in. W x 9 in. H x 4.5 in. D  
(21.6 cm W x 22.9 cm H x 11.4 cm D)  
Air Velocity**  
low speed - 100 fpm (0.5 m/s)  
high speed - 300 fpm (1.5 m/s)  
Static Discharge Time*  
@1 ft. (30 cm)  
< 2 seconds  
Offset/Balance  
+ 30V  
CE, UL  
1-year  
Certifications and Approvals  
Warranty  
* When tested according to ANSI/ESD STM3.1 at high fan speed  
** Air Velocity tested at 1 ft. distance from center of fan to Anemometer  
Customer and Technical Service  
Within the U.S.:  
Customer service and technical support can be obtained by calling the 3M Electronics Materials Solutions  
Division  
Customer Service: 866-722-3736  
Outside of the U.S.:  
For customer service and technical support, please contact your local representative of the 3M Electronics  
Materials Solutions Division.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Regulatory Information  
FCC  
This device complies with Part 15 of the FCC Rules. Operation is subject to the  
following two conditions: (1) this device may not cause harmful interference,  
and (2) this device must accept any interference received, including interference  
that may cause undesired operation.  
NOTE: This equipment has been tested and found to comply with the limits  
for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits  
are designed to provide a reasonable protection against harmful interference  
when the equipment is operated in a commercial environment. This equipment  
generates, uses, and can radiate radio frequency energy and, if not installed and  
used in accordance with the instruction manual, may cause harmful interference  
to radio communications. Operation of this equipment in a residential area is  
likely to cause harmful interference in which case the user will be required to  
correct the interference at their own expense.  
NOTE: Modifications to this device shall not be made without the written  
consent of 3M. Unauthorized modifications may void the authority granted  
under Federal Communication Rules and Industry Canada Rules permitting the  
operation of this device.  
ICES Statement  
This Class A digital apparatus meets all requirements of the Canadian  
Interference-Causing Equipment Regulations. Cet appareil numérique de la  
classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du  
Canada.  
WEEE Statement  
The following information is only for EU-members States: The mark shown  
to the right is in compliance with Waste Electrical and Electronic Equipment  
Directive 2002/96/EC (WEEE). The mark indicates the requirement NOT to  
dispose the equipment as unsorted municipal waste, but use the return and  
collection systems according to local law.  
CE Statement  
Meets EU safety, health and environmental protection requirements.  
UL Statement  
Meets UL requirements.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
RoHS 2011/65/EU” means that the product or part does not contain any of the substances in excess of the  
maximum concentration values (“MCVs”) in EU RoHS Directive 2011/65/EU. The MCVs are by weight in  
homogeneous materials. This information represents 3M’s knowledge and belief, which may be based in whole or  
in part on information provided by third party suppliers to 3M.  
3M is a trademark of 3M Company.  
Important Notice  
All statements, technical information, and recommendations related to 3M’s products  
are based on information believed to be reliable, but the accuracy or completeness is  
not guaranteed. Before using this product, you must evaluate it and determine if it is  
suitable for your intended application. You assume all risks and liability associated with  
such use. Any statements related to the product which are not contained in 3M’s current  
publications, or any contrary statements contained on your purchase order shall have no  
force or effect unless expressly agreed upon, in writing, by an authorized officer of 3M.  
Warranty; Limited Remedy; Limited Liability.  
This product will be free from defects in material and manufacture for one year from  
the time of purchase. 3M MAKES NO OTHER WARRANTIES INCLUDING, BUT  
NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY  
OR FITNESS FOR A PARTICULAR PURPOSE. If this product is defective within  
the warranty period stated above, your exclusive remedy shall be, at 3M’s option, to  
replace or repair the 3M product or refund the purchase price of the 3M product. Except  
where prohibited by law, 3M will not be liable for any indirect, special, incidental or  
consequential loss or damage arising from this 3M product, regardless of the legal  
theory asserted.  
3
Electronics Materials Solutions Division  
Static Control Products  
926 JR Industrial Drive  
Sanford, NC 27332-9733  
Toll-Free: 866-722-3736  
RoHS  
2011/65/EU  
International: 919-718-0000  
Please recycle. Printed in USA.  
© 3M 2014. All rights reserved.  
78-9102-1494-5 JHA  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Acer Tablet NTL0KAA001 User Manual
AEG Freezer A62000GNW0 User Manual
AEG Washer 76760 User Manual
Airlink GPS Receiver Raven GPRS User Manual
AKG Acoustics Headphones K702 User Manual
Altinex Computer Hardware MT103 123 User Manual
Atlona Car Satellite TV System AT PROHD44M SR User Manual
Avenview TV Converter Box VTS C5 R User Manual
Axis Communications Security Camera FD R M12 User Manual
Axxess Interface Automobile Accessories OESWC 8113 RF User Manual