3Com IP Phone V7111 User Manual

3Com® VCXV7111  
VoIP Gateway  
Installation Guide  
System Release 4.8  
Part Number 900-0391-01 Rev AB  
Published December 2006  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
CONTENTS  
ABOUT THIS GUIDE 7  
How to Use This Guide 8  
Conventions 9  
Documentation Comments 9  
Notices 9  
WEEE EU Directive 9  
Abbreviations and Terminology 10  
CHAPTER 1: QUICK START 11  
CHAPTER 2: INSTALLING THE V7111 13  
Installing the V7111 13  
Unpacking 13  
Package Contents 14  
19-inch Rack Installation Package 14  
Mounting the V7111 14  
Cabling the V7111 16  
Installing the V7111 24-PORT 18  
Unpacking 19  
Package Contents 19  
Mounting the V7111 24-PORT 19  
Cabling the V7111 24-PORT 21  
CHAPTER 3: CONFIGURING THE V7111 25  
Assigning the V7111 IP Address 25  
Assigning an IP Address Using HTTP 26  
Assigning an IP Address Using BootP 27  
Assigning an IP Address Using the Voice Menu Guidance 28  
Assigning an IP Address Using the CLI 29  
Restoring Networking Parameters to Their Initial State 30  
Accessing the Embedded Web Server 31  
3Com VCX V7111 Analog Gateway Installation Guide  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Basic Control Protocol Parameters 32  
Configuring Basic MGCP Parameters 32  
Configuring Basic H.323 Parameters 34  
Configuring Basic SIP Parameters 36  
Example of Connecting Two xxx Devices 38  
CHAPTER 4: CHANGING THE V7111 USERNAME AND PASSWORD 39  
CHAPTER 5: RESTORING AND BACKING UP THE V7111 CONFIGURATION 41  
CHAPTER 6: MONITORING THE V7111 43  
Monitoring the V7111 Front Panel LEDs 43  
Monitoring the V7111 Channels 44  
CHAPTER 7: UPGRADING THE V7111 47  
Software Upgrade Wizard 47  
Updating the Auxiliary Files 53  
CHAPTER 8: REGULATORY INFORMATION 57  
V7111 FXS Regulatory Information 57  
Safety Notice 59  
Telecommunication Safety 59  
FCC Statement 59  
V7111 FXO Regulatory Information 60  
Safety Notice 61  
Industry Canada Notice 61  
Network Compatibility 62  
Telecommunication Safety 62  
MP-1xx FXO Notice 62  
FCC Statement 62  
V7111 FXS +FXO Regulatory Information 64  
Safety Notice 65  
Telecommunications Safety 66  
FCC Statement 66  
V7111 24-PORT 67  
Safety Notice 68  
Telecommunication Safety 69  
4
3Com VCX V7111 Analog Gateway Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FCC Statement 69  
OBTAINING SUPPORT FOR YOUR 3COM PRODUCT 71  
Customer Support 71  
3Com VCX V7111 Analog Gateway Installation Guide  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
6
3Com VCX V7111 Analog Gateway Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ABOUT THIS GUIDE  
This guide describes the installation of the V7111 VoIP media gateways. The model  
numbers that this manual supports are:  
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
VCX V7111 VoIP Gateway 2 FXS (3CRVG71115-07)  
VCX V7111 VoIP Gateway 4 FXS (3CRVG71110-07)  
VCX V7111 VoIP Gateway 8 FXS (3CRVG71111-07)  
VCX V7111 VoIP Gateway 24 FXS (3CRVG71112-07)  
VCX V7111 VoIP Gateway 4 FXO (3CRVG71113-07)  
VCX V7111 VoIP Gateway 8 FXO (3CRVG71114-07)  
VCX V7111 VoIP Gateway 2 FXS, 2FXO (3CRVG71116-07)  
VCX V7111 VoIP Gateway 4 FXS, 4 FXO (3CRVG71117-07)  
Information contained in this document is believed to be accurate and reliable at the time of  
printing. However, because of on-going product improvements and revisions, 3Com cannot  
guarantee the accuracy of printed material after the Date Published nor can it accept  
responsibility for errors or omissions. Updates to this document and other documents can be  
viewed by registered Technical Support customers at www.3Com.com under Support /  
Product Documentation.  
When viewing this manual on CD, Web site or on any other electronic copy, all  
cross-references are hyperlinked. Click on the page or section titles (shown in blue)  
to reach the individual cross-referenced item directly. To return back to the point  
from where you accessed the cross-reference, press the ALT and keys.  
3Com VCX V7111 Analog Gateway Installation Guide  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
How to Use This Guide  
This book covers these topics:  
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
8
3Com VCX V7111 Analog Gateway Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Conventions  
Table 1 lists conventions that are used throughout this guide.  
Table 1  
Notice Icons  
Icon  
Notice Type  
Description  
Information note  
Information that describes important features or  
instructions.  
Caution  
Warning  
Information that alerts you to potential loss of data or  
potential damage to an application, device, system,  
or network.  
Information that alerts you to potential personal injury  
or death.  
Documentation Comments  
Your suggestions are important to us because we want to make our documentation more  
useful to you.  
Please send e-mail comments about this guide or any of the V7111 documentation and Help  
systems to:  
Please include the following information with your comments:  
ƒ
ƒ
ƒ
ƒ
Document title  
Document part number (usually found on the front page)  
Page number  
Your name and organization (optional)  
See the Appendix Obtaining Support for Your Product for how to register your product and  
get support from 3Com.  
Notices  
WEEE EU Directive  
Pursuant to the WEEE EU Directive, electronic and electrical waste must not be disposed of  
with unsorted waste. Please contact your local recycling authority for disposal of this product.  
3Com VCX V7111 Analog Gateway Installation Guide  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Abbreviations and Terminology  
Each abbreviation, unless widely used, is spelled out in full when first used. Only industry-  
standard terms are used throughout this manual. Hexadecimal notation is indicated by 0x  
preceding the number.  
Where "network" appears in this manual, it means LAN, WAN, etc. accessed via  
the gateway's Ethernet interface.  
FXO (Foreign Exchange Office) is the interface replacing the analog telephone  
and connects to a Public Switched Telephone Network (PSTN) line from the  
Central Office (CO) or to a Private Branch Exchange (PBX). The FXO is designed  
to receive line voltage and ringing current, supplied from the CO or the PBX (just  
like an analog telephone). An FXO VoIP gateway interfaces between the CO/PBX  
line and the Internet.  
FXS (Foreign Exchange Station) is the interface replacing the Exchange (i.e., the  
CO or the PBX) and connects to analog telephones, dial-up modems, and fax  
machines. The FXS is designed to supply line voltage and ringing current to these  
telephone devices. An FXS VoIP gateway interfaces between the analog  
telephone devices and the Internet.  
WARNING:  
Ensure that you connect FXS ports to analog telephone or to PBX-trunk lines only  
and FXO ports to Central Office (CO)/PBX lines only.  
The V7111 is supplied as a sealed unit and must only be installed or serviced by  
qualified service personnel.  
10  
3Com VCX V7111 Analog Gateway Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CHAPTER 1: QUICK START  
This guide provides you with information on how to install the V7111 for the first time. Prior  
knowledge of IP networks is preferred.  
Refer to the configuration procedures, outlined in Figure 1, for information on how to install,  
initialize, configure the device and make calls. For detailed information on how to fully  
configure the gateway, refer to the VCX V7111 VoIP Gateway User Manual.  
Figure 1  
Required Steps to Install the V7111  
Unpack the V7111  
Mount the V7111  
Cable the V7111  
Assign the V7111 IP Address  
Assign the V7111 IP Address  
Configure the Parameters  
3Com VCX V7111 Analog Gateway Installation Guide  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
12  
3Com VCX V7111 Analog Gateway Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CHAPTER 2: INSTALLING THE V7111  
This section provides information on the installation procedure for the V7111 (see Installing  
the V7111) and the V7111 24-PORT. For information on configuring the gateway, see  
WARNING:  
The V7111 is supplied as a sealed unit and must only be installed and serviced by  
qualified service personnel.  
Units providing power sockets with three pins must be connected by service  
personnel to a socket-outlet with a protective earthing connection.  
Installing the V7111  
To install the V7111, follow these 4 steps:  
1
2
3
4
Unpack the V7111 (see Unpacking).  
Check the package contents (see Package Contents).  
Mount the V7111 (see Mounting the V7111).  
Cable the V7111 (see Cabling the V7111).  
After connecting the V7111 to the power source, the Ready and Power LEDs on the front  
panel turn to green (after a self-testing period of about 2 minutes). Any malfunction in the  
startup procedure changes the Fail LED to red and the Ready LED is turned off (see Table10  
for details on the V7111 LEDs).  
When you have completed the above relevant sections you are then ready to start  
configuring the gateway (see Chapter 3: Configuring the V7111).  
Unpacking  
To unpack the V7111, follow these 6 steps:  
1
2
3
4
Open the carton and remove the packing materials.  
Remove the V7111 gateway from the carton.  
Check that there is no equipment damage.  
Check, retain and process any documents.  
3Com VCX V7111 Analog Gateway Installation Guide  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
5
6
Notify 3Com or your local supplier of any damage or discrepancies.  
Retain any diskettes or CDs.  
Package Contents  
Ensure that in addition to the V7111, the package contains:  
ƒ
ƒ
AC power cable.  
Small plastic bag containing four anti-slide bumpers for desktop installation.  
19-inch Rack Installation Package  
Additional option is available for installing the V7111 in a 19-inch rack. The 19-inch rack  
installation package contains a single shelf (shown in Figure 2) and eight shelf-to-device  
screws.  
Figure 2  
19-inch Rack Shelf  
Mounting the V7111  
The V7111 can be mounted on a desktop (see Mounting the V7111 on a Desktop), on a wall  
(see Mounting the V7111 on a Wall) or installed in a standard 19-inch rack (see Installing the  
Figure 3 describes the V7111 base.  
14  
3Com VCX V7111 Analog Gateway Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Figure 3  
View of the V7111 Base  
2
3
1
Table 2  
View of the V7111 Base  
Item #  
Functionality  
1
2
3
Square slot used to attach anti-slide bumpers (for desktop mounting)  
Oval notch used to attach the V7111 to a wall  
Screw opening used to attach the V7111 to a 19-inch shelf rack  
Mounting the V7111 on a Desktop  
Attach the four (supplied) anti-slide bumpers to the base of the V7111 (see item #1 in Figure  
3) and place it on the desktop in the position you require.  
Mounting the V7111 on a Wall  
To mount the V7111 on a wall, follow these 4 steps:  
1
Drill four holes according to the following dimensions:  
ƒ
ƒ
Side-to-side distance 140 mm.  
Front-to-back distance 101.4 mm.  
2
3
4
Insert a wall anchor of the appropriate size into each hole.  
Fasten a DIN 96 3.5X20 wood screw (not supplied) into each of the wall anchors.  
Position the four oval notches located on the base of the V7111 (see item #2 in Figure 3)  
over the four screws and hang the V7111 on them.  
3Com VCX V7111 Analog Gateway Installation Guide  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Installing the V7111 in a 19-inch Rack  
The V7111 is installed in a standard 19-inch rack by placing it on a shelf preinstalled in the  
rack. The 19-inch rack shelf is not supplied in the standard package kit, but can be ordered  
separately. For ordering and pricing, please contact your network distributor.  
Figure 4  
V7111 Rack Mount  
1
2
Table 3  
V7111 Rack Mount  
Item #  
Functionality  
1
2
Standard rack holes used to attach the shelf to the rack  
Eight shelf-to-device screws  
To install the V7111 in a 19-inch rack, follow these 3 steps:  
1
Use the shelf-to-device screws found in the package to attach one or two V7111 devices  
to the shelf.  
2
3
Position the shelf in the rack and line up its side holes with the rack frame holes.  
Use four standard rack screws (not supplied) to attach the shelf to the rack.  
Cabling the V7111  
Figure 5 illustrates the rear layout of the V7111. Table 4 lists and describes the rear panel  
connectors and button on the V7111.  
Cable your V7111 according to each section of Table 5  
16  
3Com VCX V7111 Analog Gateway Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Figure 5  
V7111 Rear Panel Connectors  
1
2
3
4
4
5
6
5
Table 4  
V7111 Rear Panel Component Descriptions  
Item #  
Label  
Component Description  
AC power supply socket  
10/100 Base-TX Uplink port  
1
2
3
4
5
6
100-240~0.3A max.  
Ethernet  
RS-232  
RS-232 status port (requires a DB-9 to PS/2 adaptor)  
A label that distinguishes between FXS & FXO devices  
2, 4 or 8 FXS / FXO ports  
FXS or FXO  
--  
Reset  
Reset button  
Table 5  
V7111 Cables and Cabling Procedure  
Cable  
Cabling Procedure  
Connect the Ethernet connection on the V7111 directly to the network using a  
standard RJ-45 Ethernet cable. For connector pinouts, see Figure 6.  
Note that when assigning an IP address to the V7111 using HTTP (under Step 1 in  
Assigning an IP Address Using HTTP), you may be required to disconnect this  
cable and re-cable it differently.  
RJ-45 Ethernet  
cable  
Connect the RJ-11 FXS connectors to fax  
machines, modems, or phones.  
Ensure that FXS and FXO ports are  
connected to the correct devices,  
RJ-11 two-wire  
telephone cords  
otherwise damage can occur.  
The RJ-11 pinouts are described in  
Connect the RJ-11 FXO connectors to  
telephone exchange analog lines or PBX  
extensions.  
Using a standard RS-232 straight cable (not a cross-over cable) with DB-9  
connectors, connect the V7111 RS-232 port (using a DB-9 to PS/2 adaptor) to either  
COM1 or COM2 RS-232 communication port on your PC. The pinouts of the PS/2  
connector are shown in Figure 8.  
RS-232 serial  
cable  
A PS/2 to DB-9 adaptor is not included with the V7111 package. For the PS/2 to DB-9  
pinouts, see Figure 9.  
Connect the V7111 power socket to the mains.  
AC Power cable  
3Com VCX V7111 Analog Gateway Installation Guide  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Figure 6  
RJ-45 Ethernet Connector Pinouts  
RJ-45 Connector and Pinout  
1 2 3 4 5 6 7 8  
1 - Tx+  
4, 5, 7, 8  
not  
connected  
2 - Tx-  
3 - Rx+  
6 - Rx-  
Figure 7  
Phone Connector Pinouts  
RJ-11 Connector and Pinout  
1 2 3 4  
Not connected  
Tip  
Ring  
Not connected  
1 -  
2 -  
3 -  
4 -  
Figure 8  
PS/2 Pinouts  
PS/2 Female Connector and Pinout  
(TD) - Transmit Data  
(GND) - Ground for Voltage  
(RD) - Receive Data  
2
3
6
Figure 9  
PS/2 to DB-9 Adaptor Pinouts  
Installing the V7111 24-PORT  
To install the V7111 24-PORT, follow these 4 steps:  
1
2
3
4
Unpack the V7111 24-PORT (see Unpacking).  
Check the package contents (see Package Contents).  
Mount the V7111 24-PORT (see Mounting the V7111 24-PORT).  
Cable the V7111 24-PORT (see Cabling the V7111 24-PORT).  
After connecting the V7111 24-PORT to the power source, the Ready and LAN LEDs on the  
front panel turn to green (after a self-testing period of about 1 minute). Any malfunction  
changes the Ready LED to red.  
18  
3Com VCX V7111 Analog Gateway Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
When you have completed the above relevant sections you are then ready to start  
configuring the gateway (see Chapter 3: Configuring the V7111).  
Unpacking  
To unpack the V7111 24-PORT, follow these 6 steps:  
1
2
3
4
5
6
Open the carton and remove packing materials.  
Remove the V7111 24-PORT gateway from the carton.  
Check that there is no equipment damage.  
Check, retain and process any documents.  
Notify 3Com or your local supplier of any damage or discrepancies.  
Retain any diskettes or CDs.  
Package Contents  
Ensure that in addition to the V7111 24-PORT, the package contains:  
ƒ
ƒ
AC power cable.  
2 short equal-length brackets and bracket-to-device screws for the 19-inch rack  
installation.  
Mounting the V7111 24-PORT  
The V7111 24-PORT can be mounted on a desktop or installed in a standard 19-inch rack.  
See Cabling the V7111 24-PORT for cabling the V7111 24-PORT.  
Mounting the V7111 24-PORT on a Desktop  
No brackets are required. Simply place the V7111 24-PORT on the desktop in the position  
you require.  
Figure 10 Desktop or Shelf Mounting  
3Com VCX V7111 Analog Gateway Installation Guide  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
CAUTION: Rack Mount Safety Instructions (UL)  
When installing the chassis in a rack, be sure to implement the following Safety  
instructions recommended by Underwriters Laboratories:  
Elevated Operating Ambient - If installed in a closed or multi-unit rack  
assembly, the operating ambient temperature of the rack environment may be  
greater than room ambient. Therefore, consideration should be given to  
installing the equipment in an environment compatible with the maximum  
ambient temperature (Tma) specified by the manufacturer.  
Reduced Air Flow - Installation of the equipment in a rack should be such that  
the amount of air flow required for safe operation on the equipment is not  
compromised.  
Mechanical Loading - Mounting of the equipment in the rack should be such  
that a hazardous condition is not achieved due to uneven mechanical loading.  
Circuit Overloading - Consideration should be given to the connection of the  
equipment to the supply circuit and the effect that overloading of the circuits  
might have on overcurrent protection and supply wiring. Appropriate  
consideration of equipment nameplate ratings should be used when  
addressing this concern.  
Reliable Earthing - Reliable earthing of rack-mounted equipment should be  
maintained. Particular attention should be given to supply connections other  
than direct connections to the branch circuit (e.g., use of power strips.)  
Installing the V7111 24-PORT in a 19-inch Rack  
The V7111 24-PORT is installed into a standard 19-inch rack by the addition of two short  
(equal-length) supplied brackets. The V7111 24-PORT with brackets for rack installation is  
shown in Figure 11.  
To install the V7111 24-PORT in a 19-inch rack, follow these 7 steps:  
1
2
Remove the two screws on one side of the device nearest the front panel.  
Insert the peg on one of the brackets into the third air vent down on the column of air  
vents nearest the front panel.  
3
4
Swivel the bracket until the holes in the bracket line up with the two empty screw holes  
on the device.  
Use the screws found in the devices’ package to attach the bracket to the side of the  
device.  
5
6
Repeat Steps 1 to 4 to attach the second bracket to the other side of the device.  
Position the device in the rack and line up the bracket holes with the rack frame holes.  
20  
3Com VCX V7111 Analog Gateway Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7
Use four standard rack screws to attach the device to the rack. These screws are not  
provided with the device.  
Figure 11 V7111 24-PORT with Brackets for Rack Installation  
Cabling the V7111 24-PORT  
Figure 12 illustrates the rear panel of the V7111 24-PORT. For descriptions of the V7111 24-  
PORT rear panel components, see Table 6.  
Cable your V7111 24-PORT according to each section of Table 7.  
Figure 12  
V7111 24-PORT (FXS) Rear Panel Connectors  
1
2
3
4
5
6
Table 6  
Item #  
1
V7111 24-PORT Rear Panel Component Descriptions  
Label  
Component Description  
Protective earthing screw (mandatory for all installations).  
AC power supply socket.  
100-250 V~  
50 - 60 Hz 2A  
2
3
4
5
6
ANALOG LINES 1 –24  
Data Cntrl Ready  
RS-232  
50-pin Telco for 1 to 24 analog lines.  
LED indicators (described in Table 11).  
9 pin RS-232 status port.  
Eth 1 Eth 2  
Dual 10/100 Base-TX Ethernet connections.  
3Com VCX V7111 Analog Gateway Installation Guide  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Table 7  
V7111 24-PORT Cables and Cabling Procedure  
Cable  
Cabling Procedure  
Protective  
Connect an earthed strap to the chassis protective earthing screw and fasten it securely  
earthing strap  
according to the safety standards.  
Connect the Ethernet connection on the V7111 24-PORT directly to the network using a  
standard RJ-45 Ethernet cable. For connector pinouts, see Figure 13.  
Note that when assigning an IP address to the V7111 24-PORT using HTTP (under Step  
1 see Assigning an IP Address Using HTTP), you may be required to disconnect  
this cable and re-cable it differently.  
RJ-45 Ethernet  
cable  
See the V7111 24-PORT Safety Notice below.  
Wire the 50-pin Telco connectors according to the pinouts in Figure 14, and Figure 15.  
50-pin Telco  
cable (V7111 24-  
PORT devices  
only).  
Attach each pair of wires from a 25-pair Octopus cable to its corresponding socket on the  
MDF Adaptor Block’s rear.  
Connect the wire-pairs at the other end of the cable to a male 50-pin Telco connector.  
An Octopus cable  
is not included  
with the V7111  
24-PORT  
Insert and fasten this connector to the female 50-pin Telco connector on the V7111 24-  
PORT rear panel (labeled Analog Lines 1-24).  
Connect the telephone lines from the Adaptor Block to a fax machine, modem, or  
telephones by inserting each RJ-11 connector on the 2-wire line cords of the POTS  
phones into the RJ-11 sockets on the front of an MDF Adaptor Block as shown in  
package.  
Using a standard RS-232 straight cable (not a cross-over cable) with DB-9 connectors,  
connect the V7111 24-PORT RS-232 port to either COM1 or COM2 RS-232  
communication port on your PC. The required connector pinouts and gender are shown  
RS-232 serial  
cable  
in Figure 16.  
AC Power cable Connect the V7111 24-PORT power socket to the mains.  
CAUTION: V7111 24-PORT Safety Notice  
To protect against electrical shock and fire, use a 26 AWG min wire to connect  
analog FXS lines to the 50-pin Telco connector.  
Figure 13 RJ-45 Ethernet Connector Pinouts  
RJ-45 Connector and Pinout  
1 2 3 4 5 6 7 8  
1 - Tx+  
4, 5, 7, 8  
2 - Tx-  
not  
3 - Rx+  
connected  
6 - Rx-  
22  
3Com VCX V7111 Analog Gateway Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Figure 14 50-pin Telco Connector (V7111 24-PORT/FXS only)  
Pin Numbers  
25  
1
26  
50  
Figure 15 V7111 24-PORT in a 19-inch Rack with MDF Adaptor  
FRONT INPUT  
24 line cords  
2-wire with RJ-11  
19-inch Rack  
Rear View  
connectors  
M D F Adaptor Block - rear  
REAR OUTPUT  
24 wire pairs in  
Octopus cable  
with 50-pin male  
Telco connector  
Primary  
LAN Cable  
to Eth 1  
AC Power Cord  
Back-up  
LAN Cable  
to Eth 2  
Connect to  
here  
ANALOG LINES 1-20  
RS-232  
MP-124  
Data  
Cntrl Ready  
1
2
3
4
5
CONFIG  
100  
50  
-
250V~  
Eth  
1
Eth  
2
-
60Hz 2A  
Rear View  
Grounding Strap  
50-pin female  
Telco connector  
RS-232 Cable  
3Com VCX V7111 Analog Gateway Installation Guide  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Table 8  
Pin Allocation in the 50-pin Telco Connector  
Phone Channel  
Connector Pins  
1/26  
Phone Channel  
Connector Pins  
13/38  
1
13  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
2
2/27  
14/39  
3
3/28  
15/40  
4
4/29  
16/41  
5
5/30  
17/42  
6
6/31  
18/43  
7
7/32  
19/44  
8
8/33  
20/45  
9
9/34  
21/46  
10  
11  
12  
10/35  
11/36  
12/37  
22/47  
23/48  
24/49  
Figure 16 V7111 24-PORT RS-232 Cable Wiring  
2
3
5
2
3
5
RD  
TD  
GND  
DB-9 male for V7111 24-  
DB-9 female for PC  
24  
3Com VCX V7111 Analog Gateway Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
CHAPTER 3: CONFIGURING THE V7111  
The V7111 application software already resides in the device’s flash memory when it is  
supplied (with factory default parameters). V7111 devices also include an Embedded  
(integrally stored) Web Server.  
Assigning the V7111 IP Address describes how to assign an IP address to the V7111. Basic  
Control Protocol Parameters describes how to set up the V7111 with basic parameters using  
a standard Web browser (such as Microsoft TM Internet Explorer).  
Assigning the V7111 IP Address applies equally to MGCP, H.323 and SIP.  
Assigning the V7111 IP Address  
To assign an IP address to the V7111 use one of the following methods:  
ƒ
ƒ
ƒ
HTTP using a Web browser (see Assigning an IP Address Using HTTP).  
Voice Menu using a standard touch-tone telephone connected to one of the FXS analog  
doesn’t apply to FXO gateways.  
ƒ
ƒ
The embedded Command Line Interface (CLI) accessed via Telnet or RS-232 (see  
DHCP (refer to the product’s User’s Manual).  
The default networking parameters are show in Table 9.  
Use the ‘Reset’ button at any time to restore the V7111 networking parameters to their  
3Com VCX V7111 Analog Gateway Installation Guide  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Table 9  
V7111 Default Networking Parameters  
Parameter  
FXS  
Default Value  
10.1.10.10  
10.1.10.11  
10.1.10.10  
FXO  
FXS / FXO  
V7111 default subnet mask is 255.255.0.0, default gateway IP address is 0.0.0.0  
Assigning an IP Address Using HTTP  
To assign an IP address using HTTP, follow these 8 steps:  
1
Disconnect the V7111 from the network and reconnect it to your PC using one of the  
following two methods:  
ƒ
Use a standard Ethernet cable to connect the network interface on your PC to a port  
on a network hub / switch. Use a second standard Ethernet cable to connect the  
V7111 to another port on the same network hub / switch.  
ƒ
Use an Ethernet cross-over cable (for the V7111 24-PORT) or a standard Ethernet  
cable (for the V7111) to directly connect the network interface on your PC to the  
V7111.  
2
Change your PC’s IP address and subnet mask to correspond with the V7111 factory  
default IP address and subnet mask, shown in Table 9. For details on changing the IP  
address and subnet mask of your PC, refer to Windows™ Online Help (Start>Help).  
3
4
Access the V7111 Embedded Web Server (see Accessing the Embedded Web Server).  
In the ‘Quick Setup’ screen, set the V7111 ‘IP Address’, ‘Subnet Mask’ and ‘Default  
Gateway IP Address’ fields under ‘IP Configuration’ to correspond with your network IP  
settings. If your network doesn’t feature a default gateway, enter a dummy value in the  
‘Default Gateway IP Address’ field.  
5
Click the Reset button and click OK in the prompt; the V7111 applies the changes and  
restarts. This takes approximately 2 minutes to complete. When the V7111 has finished  
restarting, the Power and Ready LEDs on the front panel are lit green.  
Record & retain the IP address and subnet mask you assign the V7111. Do the  
same when defining new username or password. If the Embedded Web Server  
is unavailable (for example, if you’ve lost your username and password), use  
the BootP/TFTP configuration utility to access the device, “reflash” the load and  
reset the password (refer to the V7111 User’s Manuals for detailed information  
on using a BootP/TFTP server to access the device).  
6
7
Disconnect your PC from the V7111 or from the hub / switch (depending on the  
connection method you used in Step 1).  
Reconnect the V7111 and your PC (if necessary) to the network.  
26  
3Com VCX V7111 Analog Gateway Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
8
Restore your PC’s IP address & subnet mask to what they originally were. If necessary,  
restart your PC and re-access the V7111 via the Embedded Web Server with its new  
assigned IP address.  
Assigning an IP Address Using BootP  
BootP procedure can also be performed using any standard compatible BootP  
server.  
You can also use BootP to load the auxiliary files to the V7111 (refer to the  
product’s User’s Manual).  
To assign an IP address using BootP, follow these 12 steps:  
1
2
Open the BootP application (supplied with the software package).  
Click on the Edit Clients icon;  
the ‘Client Configuration’ screen is displayed.  
3
4
5
Click on the Add New Client icon;  
a client with blank parameters is displayed (Figure 17).  
In the ‘Client MAC’ field, enter the MAC address of the gateway. The MAC address is  
printed on a label located on the base of the V7111.  
Verify that the box to the right of the ‘Client MAC’ field is checked. This enables the  
particular client in the BootP tool (if the client is disabled, no replies are sent to BootP  
requests).  
6
In the ‘Client Name’ field, enter a descriptive name for this client so that it is easier to  
remember which gateway the record refers to. For example, this name could refer to the  
location of the gateway.  
7
8
In the ‘IP’ field, enter the IP address you want to apply to the gateway. Use the normal  
dotted decimal format.  
In the ‘Subnet’ field, enter the subnet mask you want to apply to the gateway. Use the  
normal dotted decimal format. Ensure that the subnet mask is correct. If the address is  
incorrect, the gateway may not function until the entry is corrected and a BootP reset is  
applied.  
9
In the ‘Gateway’ field, enter the IP address for the default gateway. If you do not know  
the IP address for the default gateway, contact your network administrator.  
10 Click Apply to save this entry to the list of clients.  
11 Click OK; the ‘Client Configuration’ screen is closed.  
12 Use the reset button (located on the V7111 rear panel) to physically reset the gateway  
causing it to use BootP; the device changes its network parameters to the values  
provided by the BootP.  
3Com VCX V7111 Analog Gateway Installation Guide  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Figure 17 Client Configuration Screen with Blank Parameters  
Assigning an IP Address Using the Voice Menu Guidance  
To assign an IP address using the voice menu guidance, follow these 7 steps:  
1
Connect a telephone to one of the FXS ports. Lift the handset and dial ***12345 (three  
stars followed by the digits 1, 2, 3, 4, 5).  
2
3
Wait for the 'configuration menu' voice prompt to be played.  
To change the IP address, press 1 followed by the pound key (#).  
ƒ
ƒ
The current IP address of the gateway is played. Press # to change it.  
Dial the new IP address; use the star (*) key instead of dots ("."), e.g. 192*168*0*4  
and press # to finish.  
ƒ
Review the new IP address, and press 1 to save it.  
4
To change the subnet mask, press 2 followed by the # key.  
ƒ
ƒ
ƒ
The current subnet mask of the gateway is played. Press # to change it.  
Dial the new subnet mask; e.g. 255*255*0*0 and press # to finish.  
Review the new subnet mask, and press 1 to save it.  
28  
3Com VCX V7111 Analog Gateway Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
5
To change the default gateway IP address, press 3 followed by the # key.  
ƒ
ƒ
ƒ
The current default gateway address of the gateway is played. Press # to change it.  
Dial the new default gateway address; e.g. 192*168*0*1 and press # to finish.  
Review the new default gateway address, and press 1 to save it.  
6
7
Hang up the handset. Access the gateway's Embedded Web Server with the new IP  
address you assigned (see Accessing the Embedded Web Server).  
Reset the gateway. Click the Reset Device button on the main menu bar; the Reset  
screen is displayed. Click the button Reset (with the Burn option selected).  
Assigning an IP Address Using the CLI  
First access the CLI using a standard Telnet application or using a serial communication  
software (e.g., HyperTerminalTM) connected to the V7111 RS-232 port (see Access the CLI).  
Then assign the V7111 an IP address (see Assign an IP Address).  
Access the CLI  
To access the CLI via the Embedded Telnet Server, follow these 3 steps:  
1
Enable the Embedded Telnet Server:  
ƒ
Access the V7111 Embedded Web Server (see Accessing the Embedded Web  
Server).  
ƒ
Set the parameter ‘Embedded Telnet Server’ (under Advanced Configuration >  
Network Settings > Application Settings) to ‘Enable (Unsecured)’ or ‘Enable  
Secured (SSL)’.  
ƒ
ƒ
Click the Reset Device button on the main menu bar; the Reset screen is displayed.  
Click the Reset button in the middle of the Reset screen with the Burn option  
selected; the V7111 is shut down and re-activated. A message about the waiting  
period is displayed. The screen is refreshed.  
2
3
Use a standard Telnet application to connect to the V7111 Embedded Telnet Server.  
Note that if the Telnet server is set to SSL mode, a special Telnet client is required on  
your PC to connect to the Telnet interface over a secured connection.  
Login using the username (‘Admin’) and password (‘Admin’).  
To access the CLI via the RS-232 port, follow these 2 steps:  
1
Connect the RS-232 port to your PC (For the V7111, see Table 5. For the V7111 24-  
PORT, see Table 7).  
3Com VCX V7111 Analog Gateway Installation Guide  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
2
Use a serial communication software (e.g., HyperTerminalTM) to connect to the V7111.  
Set your serial communication software to the following communications port settings:  
ƒ
ƒ
ƒ
ƒ
ƒ
Baud Rate:  
Data bits:  
Parity:  
115,200 bps (V7111 24-PORT), 9,600 bps (V7111)  
8
None  
1
Stop bits:  
Flow control:  
None  
The CLI prompt is available immediately.  
Assign an IP Address  
To assign an IP address via the CLI, follow these 4 steps:  
1
2
At the prompt type ‘conf’ and press enter; the configuration folder is accessed.  
To check the current network parameters, at the prompt, type ‘GCP IP’ and press enter;  
the current network settings are displayed.  
3
4
Change the network settings by typing: ‘SCP IP [ip_address] [subnet_mask]  
[default_gateway]’ (e.g., ‘SCP IP 10.13.77.7 255.255.0.0 10.13.0.1’); the new settings  
take effect on-the-fly. Connectivity is active at the new IP address.  
This command requires you to enter all three network parameters (each  
separated by a space).  
To save the configuration, at the prompt, type ‘SAR’ and press enter; the V7111 restarts  
with the new network settings.  
Restoring Networking Parameters to Their Initial State  
You can use the ‘Reset’ button to restore the V7111 networking parameters to their factory  
default values (described in Table 9) and to reset the username and password.  
Note that the V7111 returns to the software version burned in flash. This process also  
restores the V7111 parameters to their factory settings. Therefore, you must load your  
previously backed-up ini file, or the default ini file (received with the software kit) to set them  
to their correct values.  
To restore the networking parameters of the V7111 to their initial state, follow these 4 steps:  
1
Press in the ‘Reset’ button uninterruptedly for a duration of more than six seconds; the  
gateway is restored to its factory settings (username: ‘Admin’, password: ‘Admin’).  
2
Assign the V7111 IP address (see Assigning the V7111 IP Address).  
30  
3Com VCX V7111 Analog Gateway Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
3
4
Load your previously backed-up ini file, or the default ini file (received with the software  
kit). To load the ini file via the Embedded Web Server, refer to the V7111 User’s Manual.  
Press again on the ‘Reset’ button (this time for a short period).  
To restore the networking parameters of the V7111 24-PORT to their initial state, follow  
these 6 steps:  
1
2
Disconnect the V7111 24-PORT from the power and network cables.  
Reconnect the power cable; the gateway is powered up. After approximately 45 seconds  
the Ready LED turns to green and the Control LED blinks for about 3 seconds.  
3
While the Control LED is blinking, press shortly on the reset button (located on the left  
side of the front panel); the gateway resets a second time and is restored with factory  
default parameters (username: ‘Admin’, password: ‘Admin’).  
4
5
6
Reconnect the network cable.  
Assign the V7111 24-PORT IP address (see Assigning the V7111 IP Address).  
Load your previously backed-up ini file, or the default ini file (received with the software  
kit). To load the ini file via the Embedded Web Server, refer to the V7111 User’s Manual.  
Accessing the Embedded Web Server  
To access the Embedded Web Server, follow these 4 steps:  
1
Open a standard Web-browsing application such as Microsoft™ Internet Explorer™  
(Version 6.0 and higher) or Netscape™ Navigator™ (Version 7.2 and higher).  
2
Embedded Web Server’s ‘Enter Network Password’ screen appears, shown in Figure 18.  
Figure 18 Embedded Web Server Login Screen  
3
In the ‘User Name’ and ‘Password’ fields, enter the username (default: “Admin”) and  
password (default: “Admin”). Note that the username and password are case-sensitive.  
3Com VCX V7111 Analog Gateway Installation Guide  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
4
Click OK; the ‘Quick Setup’ screen is accessed, shown in Figure 19 (MGCP), Figure 20  
(H.323), and Figure 21 (SIP).  
Basic Control Protocol Parameters  
To configure the V7111 basic control protocol parameters use the Embedded Web Server’s  
‘Quick Setup’ screen.  
ƒ
ƒ
ƒ
When you have completed the above relevant section you are then ready to start using the  
V7111. For information on how to fully configure the VoIP gateway, refer to the V7111 User’s  
Manuals.  
Once the gateway is configured correctly, back up your settings by making a copy  
of the VoIP gateway configuration (ini file) and store it in a directory on your PC.  
This saved file can be used to restore configuration settings at a future time. For  
information on backing up and restoring the gateway’s configuration, see Chapter  
The following configuring Sections from here up to and including Configuring Basic  
SIP Parameters apply individually to MGCP, H.323, or SIP.  
MGCP configuring continues with Configuring Basic MGCP Parameters.  
H.323 configuring continues with Configuring Basic H.323 Parameters.  
SIP configuring continues with Configuring Basic SIP Parameters.  
Configuring Basic MGCP Parameters  
After accessing the Embedded Web Server (see Accessing the Embedded Web Server) the  
MGCP ‘Quick Setup’ screen is displayed, shown in Figure 19.  
32  
3Com VCX V7111 Analog Gateway Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Figure 19 V7111 MGCP Quick Setup Screen  
To configure basic MGCP parameters, follow these 10 steps:  
1
If your network features a DNS server, in the fields ‘DNS Primary Server IP’ and ‘DNS  
Secondary Server IP’, enter the IP address of the primary and secondary DNS servers  
(clarify with your network administrator). Note that the DNS server option is not  
supported by MGCP.  
2
If your network features a DHCP server, in the ‘Enable DHCP’ field, select ‘Enable’; the  
‘IP Address’, ‘Subnet Musk’ and ‘Default Gateway IP Address’ fields are disabled. When  
the gateway is configured to use DHCP, it attempts to contact the DHCP server to obtain  
the networking parameters (i.e., IP address, subnet mask, default gateway and  
primary/secondary DNS server).  
3
4
Select ‘MGCP’ in the ‘Control Protocol Type’ field.  
In the ‘Call Agent IP’ field, enter the Call Agent IP address if your enterprise’s network  
doesn’t feature a DNS server that automatically defines the Call Agent’s IP address. If  
you have a DNS server, the field is optional.  
5
6
In the ‘Call Agent Port’ field, enter the Call Agent port. The default is 2427.  
In the ‘Call Agent Domain Name’ field, enter the Call Agent domain name. When using  
the DNS server option, enter the domain name of the Call Agent operating with the  
V7111. The DNS server automatically detects the Call Agent’s IP address from the  
domain name.  
3Com VCX V7111 Analog Gateway Installation Guide  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
7
In the ‘Gateway Name’ field, enter a name to the device. (For example: ‘gateway1.com’).  
Ensure that the name you choose is the one that the Call Manager/Agent is configured  
with to identify your V7111.  
8
9
In the ‘Endpoint Name’ field, enter an intuitive endpoint name. Ensure that the endpoint  
name you choose is the one that the Call Agent works with.  
In the ‘Endpoint Numbering Offset’ field, you can enter a value to offset the numbers that  
represent the gateway’s endpoints.  
10 Click the Reset button and click OK in the prompt; the V7111 applies the changes and  
restarts. This takes approximately 2 minutes to complete. When the V7111 has finished  
restarting, the Power and Ready LEDs on the front panel are lit green.  
MGCP users should continue with Chapter 4: Changing the V7111 Username and  
Configuring Basic H.323 Parameters  
After accessing the Embedded Web Server (see Accessing the Embedded Web Server) the  
H.323 ‘Quick Setup’ screen is displayed, shown in Figure 20.  
Figure 20 V7111 H.323 Quick Setup Screen  
34  
3Com VCX V7111 Analog Gateway Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
To configure basic H.323 parameters, follow these 7 steps:  
1
If the V7111 is connected to a router with NAT enabled, perform the following procedure.  
If it isn’t, leave the ‘NAT IP Address’ field undefined.  
ƒ
Determine the “public” IP address assigned to the router (by using, for instance,  
router Web management). Enter this public IP address in the ‘NAT IP Address’ field.  
ƒ
Enable the DMZ configuration on the residential router for the LAN port where the  
V7111 gateway is connected. This enables unknown packets to be routed to the  
DMZ port.  
2
When working with a Gatekeeper, set ‘Working with Gatekeeper’ field, under ‘H.323  
Parameters’, to ‘Yes’ and enter the IP address of the primary Gatekeeper in the field  
‘Gatekeeper IP Address’. When no Gatekeeper is used, the internal routing table is used  
to route the calls.  
3
4
Leave parameter ‘Enable Annex D/T.38 FAX Relay’ at its default unless your technical  
requirements differ.  
Select the coder (i.e., vocoder) that best suits your VoIP system requirements. The  
default coder is: G.723.1 30 msec. To program the entire list of coders you want the  
V7111 to use, refer to the V7111 User’s Manual.  
5
Map outgoing calls to IP addresses (when Gatekeeper isn’t used) by completing these  
steps:  
ƒ
Click the arrow button next to the ‘Tel to IP Routing Table’ label; the ‘Tel to IP  
Routing’ screen opens.  
Any telephone number whose destination number matches the prefix defined in the  
‘Destination Phone Prefix’ field and whose source number matches the prefix defined  
in the adjacent ‘Source Phone Prefix‘ field, is sent to the IP address entered in the ‘IP  
Address’ field.  
ƒ
ƒ
Click the Submit button; the ‘Tel to IP Routing’ table is automatically updated.  
Click Quick Setup; you’re returned to the ‘Quick Setup’ screen.  
For more information on the ‘Tel to IP Routing’ table refer to the V7111 H.323 User’s  
Manual.  
6
Allocate V7111 endpoints (analog lines) and their corresponding phone numbers to  
incoming IP calls by completing these steps:  
ƒ
ƒ
ƒ
ƒ
Click the arrow button next to the ‘Endpoint Phone Number’ label; the ‘Endpoint  
Phone Numbers’ screen opens.  
Enter the number of a channel, starting with 1, (or a group of channels), under the  
‘Channel(s)’ column (for example 1-4 for the first 4 endpoints).  
Assign each channel a phone number (for a group of channels, define the first  
number in an ordered sequence).  
Click the Submit button; the ‘Endpoint Phone Number’ table is automatically  
updated.  
3Com VCX V7111 Analog Gateway Installation Guide  
35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ƒ
Click Quick Setup; you’re returned to the ‘Quick Setup’ screen.  
7
Click the Reset button and click OK in the prompt; the V7111 applies the changes and  
restarts. This takes approximately 2 minutes to complete. When the V7111 has finished  
restarting, the Power and Ready LEDs on the front panel are lit green.  
Configuring Basic SIP Parameters  
After accessing the Embedded Web Server (see Accessing the Embedded Web Server) the  
SIP ‘Quick Setup’ screen is displayed, shown in Figure 21.  
Figure 21 V7111 SIP Quick Setup Screen  
36  
3Com VCX V7111 Analog Gateway Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
To configure basic SIP parameters, follow these 9 steps:  
1
If the V7111 is connected to a router with NAT enabled, perform the following procedure.  
If it isn’t, leave the ‘NAT IP Address’ field undefined.  
ƒ
Determine the “public” IP address assigned to the router (by using, for instance,  
router Web management). Enter this public IP address in the ‘NAT IP Address’ field.  
ƒ
Enable the DMZ configuration on the residential router for the LAN port where the  
V7111 gateway is connected. This enables unknown packets to be routed to the  
DMZ port.  
2
3
Under ‘SIP Parameters’, enter the V7111 Domain Name in the field ‘Gateway Name’. If  
the field is not specified, the V7111 IP address is used instead (default).  
When working with a Proxy server, set ‘Working with Proxy’ field to ‘Yes’ and enter the IP  
address of the primary Proxy server in the field ‘Proxy IP Address’. When no Proxy is  
used, the internal routing table is used to route the calls.  
4
5
Enter the Proxy Name in the field ‘Proxy Name’. If Proxy name is used, it replaces the  
Proxy IP address in all SIP messages. This means that messages are still sent to the  
physical Proxy IP address but the SIP URI contains the Proxy name instead.  
Configure ‘Enable Registration’ to ‘Yes’ or ‘No’:  
‘No’ = the V7111 does not register to a Proxy server/Registrar (default).  
‘Yes’ = the V7111 registers to a Proxy server/Registrar at power up and every  
‘Registration Time’ seconds; The V7111 sends a register request for each channel or for  
the entire gateway (according to the ‘Authentication Mode’ parameter). For detailed  
information on the parameters ‘Registration Time’ and ‘Authentication Mode’, refer to the  
V7111 SIP User’s Manual.  
6
7
Select the coder (i.e., vocoder) that best suits your VoIP system requirements. The  
default coder is: G.723.1 30 msec. To program the entire list of coders you want the  
V7111 to use, refer to the V7111 User’s Manual.  
Map outgoing calls to IP addresses (when Proxy isn’t used) by completing these steps:  
ƒ
Click the arrow button next to the ‘Tel to IP Routing Table’ label; the ‘Tel to IP  
Routing’ screen opens.  
Any telephone number whose destination number matches the prefix defined in the  
‘Destination Phone Prefix’ field and whose source number matches the prefix defined  
in the adjacent ‘Source Phone Prefix‘ field, is sent to the IP address entered in the ‘IP  
Address’ field.  
ƒ
ƒ
Click the Submit button; the ‘Tel to IP Routing’ table is automatically updated.  
Click Quick Setup; you’re returned to the ‘Quick Setup’ screen.  
For more information on the ‘Tel to IP Routing’ table refer to the V7111 SIP User’s  
Manual.  
3Com VCX V7111 Analog Gateway Installation Guide  
37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
8
Allocate V7111 endpoints (analog lines) and their corresponding phone numbers to  
incoming IP calls by completing these steps:  
ƒ
ƒ
ƒ
ƒ
ƒ
Click the arrow button next to the ‘Endpoint Phone Number’ label; the ‘Endpoint  
Phone Numbers’ screen opens.  
Enter the number of a channel, starting with 1, (or a group of channels), under the  
‘Channel(s)’ column (for example 1-4 for the first 4 endpoints).  
Assign each channel a phone number (for a group of channels, define the first  
number in an ordered sequence)  
Click the Submit button; the ‘Endpoint Phone Number’ table is automatically  
updated.  
Click Quick Setup; you’re returned to the ‘Quick Setup’ screen.  
9
Click the Reset button and click OK in the prompt; the V7111 applies the changes and  
restarts. This takes approximately 2 minutes to complete. When the V7111 has finished  
restarting, the Power and Ready LEDs on the front panel are lit green.  
Example of Connecting Two xxx Devices  
Not applicable at this release.  
Figure 22 Example of Connecting Two xxx Devices  
Not applicable at this release.  
38  
3Com VCX V7111 Analog Gateway Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CHAPTER 4: CHANGING THE V7111  
USERNAME AND PASSWORD  
To prevent unauthorized access to the Embedded Web Server, two user accounts are  
available, a primary and secondary. For detailed information on the user account  
mechanism, refer to the V7111 User’s Manual.  
It is recommended that you change the default username and password of the account you  
use to access the Embedded Web Server.  
To change the username and password, follow these 3 steps:  
1
Open the ‘Web User Accounts’ screen (Advanced Configuration menu > Security  
Settings > Web User Accounts option); the ‘Web User Accounts’ screen is displayed.  
Figure 23 Web User Accounts Screen  
3Com VCX V7111 Analog Gateway Installation Guide  
39  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
2
3
To change the username of an account, enter the new username in the field ‘User Name’  
and click the button Change User Name; the new username is applied immediately and  
the ‘Enter Network Password’ screen appears (shown in Figure 18). Enter the updated  
username in the ‘Enter Network Password’ screen. Note that the username can be a  
maximum of 19 case-sensitive characters.  
To change the password of an account, enter the current password in the field ‘Current  
Password’, the new password in the fields ‘New Password’ and ‘Confirm New Password’  
and click the button Change Password; the new password is applied immediately and  
the ‘Enter Network Password’ screen appears (shown in Figure 18). Enter the updated  
password in the ‘Enter Network Password’ screen. Note that the password can be a  
maximum of 19 case-sensitive characters.  
40  
3Com VCX V7111 Analog Gateway Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CHAPTER 5: RESTORING AND BACKING UP  
THE V7111 CONFIGURATION  
The ‘Configuration File’ screen enables you to restore (load a new ini file to the gateway) or  
to back up (make a copy of the VoIP gateway ini file and store it in a directory on your PC)  
the current configuration the gateway is using.  
Back up your configuration if you want to protect your VoIP gateway programming. The  
backup ini file includes only those parameters that were modified and contain other than  
default values.  
Restore your configuration if the VoIP gateway has been replaced or has lost its  
programming information, you can restore the VoIP gateway configuration from a previous  
backup or from a newly created ini file. To restore the VoIP gateway configuration from a  
previous backup you must have a backup of the VoIP gateway information stored on your  
PC.  
To restore or back up the ini file:  
ƒ
Open the ‘Configuration File’ screen (Advanced Configuration menu > Configuration  
File); the ‘Configuration File’ screen is displayed.  
Figure 24 Configuration File Screen  
3Com VCX V7111 Analog Gateway Installation Guide  
41  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
To back up the ini file, follow these 4 steps:  
1
2
3
4
Click the Get ini File button; the ‘File Download’ window opens.  
Click the Save button; the ‘Save As’ window opens.  
Navigate to the folder where you want to save the ini file.  
Click the Save button; the VoIP gateway copies the ini file into the folder you selected.  
To restore the ini file, follow these 4 steps:  
1
2
3
Click the Browse button.  
Navigate to the folder that contains the ini file you want to load.  
Click the file and click the Open button; the name and path of the file appear in the field  
beside the Browse button.  
4
Click the Send ini File button, and click OK in the prompt; the gateway is automatically  
reset (from the cmp version stored on the flash memory).  
42  
3Com VCX V7111 Analog Gateway Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CHAPTER 6: MONITORING THE V7111  
The V7111 provides several ways of monitoring the status of the gateway:  
ƒ
ƒ
Monitoring the V7111 front panel LEDs (see Monitoring the V7111 Front Panel LEDs).  
Monitoring the V7111 channels via the Embedded Web Server (see Monitoring the  
Monitoring the V7111 Front Panel LEDs  
The V7111 front panel LEDs indicate the Ethernet LAN status, Data (RTP) activity and state  
of the gateway ports. Table 10 and Table 12 describe the meaning of each state of the LEDs  
on the front panel.  
Table 10  
Definition of V7111 Front Panel LED Indicators  
LED  
Type  
Color  
State  
On  
Definition  
Device powered, self-test OK  
Software loading or System failure  
Valid 10/100 Base-TX Ethernet connection  
No uplink  
Device  
Status  
Ready  
Uplink  
Green  
Off  
On  
Ethernet  
Link Status  
Green  
Green  
Off  
On  
Power is currently being supplied to the device  
Power  
Supply  
Status  
Power  
Fail  
Either there’s a failure / disruption in the AC power  
supply or power is currently not being supplied to the  
device through the AC power supply entry.  
Off  
On  
Failure (fatal error).  
Or system initialization.  
Failure  
Indication  
Red  
Off  
Normal working condition  
Blinking  
The phone is ringing (incoming call, before answering).  
Fast  
Blinking  
Line malfunction  
Channels Telephone  
Status  
Interface  
Green  
Off  
On  
Normal onhook position  
Offhook  
3Com VCX V7111 Analog Gateway Installation Guide  
43  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Table 11  
Definition of V7111 24-PORT Front Panel LED Indicators  
Label  
Type  
Color  
Green  
Orange  
Red  
State  
ON  
Function  
Device Powered, self-test OK  
Software Loading/Initialization  
Malfunction  
Ready  
Device Status  
Blinking  
ON  
Green  
Red  
ON  
Valid 10/100 Base-TX Ethernet connection  
Malfunction  
Ethernet Link  
Status  
LAN  
ON  
Green  
Blank  
Green  
Blinking  
Sending and receiving SIP messages  
No traffic  
Control  
Control Link  
Blinking  
Transmitting RTP (Real-Time Transport  
Protocol) Packets  
Data  
Packet Status  
Red  
Blinking  
Receiving RTP Packets  
No traffic  
Blank  
Green  
-
ON  
Offhook / Ringing for FXS Phone Port  
FXO Line-Seize/Ringing State for Line Port  
There’s an incoming call, before answering  
Line Malfunction  
Telephone  
Interface  
Channels  
Green  
Red  
Blinking  
ON  
-
Blank  
Normal  
Monitoring the V7111 Channels  
To monitor the status of the channels:  
ƒ
Open the Channel Status screen (Status & Diagnostics menu > Channel Status); the  
Channel Status screen is displayed.  
Figure 25 V7111/FXS Channel Status Screen  
44  
3Com VCX V7111 Analog Gateway Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
The color of each channel shows the call status of that channel. See Table 12 for information  
on the different statuses a call can have.  
Table 12  
Channel Status Color Indicators  
Indicator  
Color  
Label  
Description  
Gray  
Inactive  
Indicates this channel is currently onhook  
Lime GreenRTP Active  
Indicates an active RTP stream.  
Not Connected (FXO  
only)  
Red  
Blue  
Indicates that no analog line is connected to this port.  
Indicates this channel is offhook but there is no active  
RTP session.  
Handset Offhook  
To monitor the details of a channel, follow these 2 steps:  
1
In the Channel Status screen, click the numbered icon of the specific channel whose  
detailed status you need to check/monitor; the channel-specific Channel Status screen  
appears.  
2
Click the submenu links to check/view a specific channel’s parameter settings  
3Com VCX V7111 Analog Gateway Installation Guide  
45  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
46  
3Com VCX V7111 Analog Gateway Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CHAPTER 7: UPGRADING THE V7111  
To upgrade the V7111 (load new software or auxiliary files onto the VoIP gateway) use the  
Software Update feature, available through the Embedded Web Server.  
The ‘Software Update’ menu comprises two submenus:  
ƒ
ƒ
Software Update Wizard (see Software Upgrade Wizard).  
Auxiliary Files (see Updating the Auxiliary Files).  
When you upgrade the V7111 software you must load the new cmp file with all  
other related configuration files: coefficient, Call Progress Tones, Voice Prompts  
and Prerecorded Tones.  
Software Upgrade Wizard  
The Software Upgrade Wizard guides users through the process of software upgrade:  
selecting files and loading them to the gateway. The wizard also enables users to upgrade  
software while maintaining the existing configuration. Using the wizard obligates users to  
load a cmp file. Users can choose to also use the Wizard to load auxiliary files (ini, Call  
Progress Tones, Voice Prompts and FXS coefficient files) but this option cannot be pursued  
without loading the cmp file. For each auxiliary file type, users can choose to reload an  
existing file, load a new file or not load a file at all.  
The Software Upgrade Wizard requires the device to be reset at the end of the  
process. This disrupts any traffic existing on the device. To avoid disruption,  
disable all traffic on the device before initiating the Wizard.  
To use the Software Upgrade Wizard, follow these 9 steps:  
1
2
Stop all traffic on the device (refer to the note above).  
Open the ‘Software Upgrade Wizard’ (Software Update menu > Software Upgrade  
Wizard); the ‘Start Software Upgrade’ screen appears.  
3Com VCX V7111 Analog Gateway Installation Guide  
47  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Figure 26 Start Software Upgrade Screen  
At this point, the process can be canceled with no consequence to the device (click  
the Cancel button). If you continue the process (by clicking the Start Software  
Upgrade button, the process must be followed through and completed with a  
device reset at the end. If you click the Cancel button in any of the subsequent  
screens, the device is automatically reset with the configuration that was previously  
burned in flash memory.  
3
Click the Start Software Upgrade button; the ‘Load a cmp file’ screen appears (Figure  
27).  
When in the Wizard process, the rest of the Web application is unavailable and the  
background Web screen is disabled. After the process is completed, access to the  
full Web application is restored.  
48  
3Com VCX V7111 Analog Gateway Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Figure 27 Load a cmp File Screen  
4
Click the Browse button, navigate to the cmp file and click the button Send File; the cmp  
file is loaded to the device and you’re notified as to a successful loading (see Figure 28).  
Figure 28 File Successfully Loaded into the Device Notification  
5
Note that the four action buttons (Cancel, Reset, Back, and Next) are now activated  
(following cmp file loading).  
3Com VCX V7111 Analog Gateway Installation Guide  
49  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
You can now choose to either:  
ƒ
Click Reset; the device resets, utilizing the new cmp you loaded and utilizing the  
current configuration files.  
ƒ
Click Cancel; the device resets utilizing the cmp, ini and all other configuration files  
that were previously stored in flash memory. Note that these are NOT the files you  
loaded in the previous Wizard steps.  
ƒ
ƒ
Click Back; the ‘Load a cmp File’ screen is reverted to; see Figure 27.  
Click Next; the ‘Load an ini File’ screen opens; see Figure 29. Loading a new ini file  
or any other auxiliary file listed in the Wizard is optional.  
Note that as you progress, the file type list on the left indicates which file type loading is  
in process by illuminating green (until ‘FINISH’).  
Figure 29 Load an ini File Screen  
6
In the ‘Load an ini File’ screen, you can now choose to either:  
ƒ
Click Browse and navigate to the ini file; the check box ‘Use existing configuration’,  
by default checked, becomes unchecked. Click Send File; the ini file is loaded to the  
device and you’re notified as to a successful loading.  
ƒ
ƒ
Ignore the Browse button (its field remains undefined and the check box ‘Use  
existing configuration’ remains checked by default).  
Ignore the Browse button and uncheck the ‘Use existing configuration’ check box; no  
ini file is loaded, the device uses its factory-preconfigured values.  
50  
3Com VCX V7111 Analog Gateway Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
You can now choose to either:  
ƒ
Click Cancel; the device resets utilizing the cmp, ini and all other configuration files  
that were previously stored in flash memory. Note that these are NOT the files you  
loaded in the previous Wizard steps.  
ƒ
Click Reset; the device resets, utilizing the new cmp and ini file you loaded up to now  
as well as utilizing the other configuration files.  
ƒ
ƒ
Click Back; the ‘Load a cmp file’ screen is reverted to; see Figure 27.  
Click Next; the ‘Load a CPT File’ screen opens (see Figure 30); Loading a new CPT  
file or any other auxiliary file listed in the Wizard is optional.  
Figure 30 Load a CPT File Screen  
7
8
Follow the same procedure you followed when loading the ini file (see Step 6). The same  
procedure applies to the ‘Load a VP file’ (not applicable to the V7111 gateway) screen  
and ‘Load a coefficient file’ screen.  
In the ‘FINISH’ screen (see Figure 31), the Next button is disabled. Complete the  
upgrade process by clicking Reset or Cancel.  
ƒ
ƒ
Click Reset, the V7111 ‘burns’ the newly loaded files to flash memory. The ‘Burning  
files to flash memory’ screen appears. Wait for the ‘burn’ to finish. When it finishes,  
the ‘End Process’ screen appears displaying the burned configuration files (see  
Click Cancel, the V7111 resets, utilizing the files previously stored in flash memory.  
(Note that these are NOT the files you loaded in the previous Wizard steps).  
3Com VCX V7111 Analog Gateway Installation Guide  
51  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Figure 31 FINISH Screen  
Figure 32 ‘End Process’ Screen  
9
Click the End Process button; the ‘Quick Setup’ screen appears and the full Web  
application is reactivated.  
52  
3Com VCX V7111 Analog Gateway Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Updating the Auxiliary Files  
The auxiliary files are configuration dat files that are loaded to the gateway (in addition to the  
ini file) to enable enhanced gateway provisioning. The following common auxiliary files are  
available: coefficient, Voice Prompts (MGCP only) and Call Progress Tones (CPT). For  
information on additional auxiliary files, refer to the V7111 User’s Manual. Table 13 presents  
a brief description of the ini file and of each auxiliary file.  
Table 13  
ini and Auxiliary Files Descriptions  
File Type  
Ini  
Description  
Load this file to provision the device’s parameters. The Embedded Web Server  
enables practically full device provisioning but customers may occasionally require  
new feature configuration parameters in which case this file is loaded.  
Note that loading the ini file only provisions parameters that are contained in the ini file.  
If a parameter is not specified in the ini file, values associated with that parameter are  
reset to a default value. These values may not be the same as the values that were  
configured for the VoIP gateway at the time of manufacture.  
After the file has completed loading, the VoIP gateway automatically  
restarts (software is loaded from the flash).  
FXS Coefficient  
This file contains the telephony interface configuration information for the VoIP  
gateway. This information includes telephony interface characteristics, such as DC and  
AC impedance, feeding current and ringing voltage. This file is specific to the type of  
telephony interface that the VoIP gateway supports. In most cases you have to load  
this type of file.  
Use the parameter ‘CountryCoefficients‘ (described in the V7111 User’s  
Manual) to configure the FXO coefficients.  
Voice Prompts  
The voice announcement file contains a set of Voice Prompts to be played by the  
V7111 during operation on Call Agent request. Only MGCP is supported.  
Call Progress  
Tones  
This is a region-specific, telephone exchange-dependent file that contains the Call  
Progress Tones levels and frequencies that the VoIP gateway uses. Default CPT file:  
U.S.A.  
To load an auxiliary file via the Embedded Web Server, follow these 6 steps:  
1
Open the ‘Auxiliary Files’ screen (Software Update menu > Load Auxiliary Files); the  
‘Auxiliary Files’ screen is displayed (shown Figure 33).  
2
3
4
Click the Browse button that is in the field for the type of file you want to load.  
Navigate to the folder that contains the file you want to load.  
Click the file and click the Open button; the name and path of the file appear in the field  
next to the Browse button.  
5
6
Click the Send File button adjacent to the field that contains the name of the file you  
want to load. An asterisk in the screen section indicates that the file’s loading takes effect  
on-the-fly (e.g., Voice Prompts file).  
Repeat Steps 2 to 5 for each file you want to load.  
3Com VCX V7111 Analog Gateway Installation Guide  
53  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Figure 33 Auxiliary Files Screen (MGCP Gateways)  
To save the loaded auxiliary files to flash memory, follow these 2 steps:  
1
Click the Save Configuration button on the main menu bar; the ‘Save Configuration to  
the Flash Memory’ screen is displayed.  
Saving an auxiliary file to flash memory may disrupt traffic on the device. To  
avoid this, disable all traffic on the device before saving to flash memory.  
2
Click the Save Configuration button in the middle of the screen; a confirmation  
message appears when the save is complete.  
A device reset is required to activate a loaded CPT file, and may be required  
for the activation of certain ini file parameters.  
54  
3Com VCX V7111 Analog Gateway Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
To reset the V7111, follow these 2 steps:  
1
2
Click the Reset Device button on the main menu bar; the ‘Reset’ screen is displayed.  
Click the Reset button in the middle of the screen; the auxiliary files are saved into flash  
and the V7111 restarts. This takes approximately 2 minutes to complete. When the  
V7111 has finished restarting, the Power and Ready LEDs on the front panel are lit  
green.  
3Com VCX V7111 Analog Gateway Installation Guide  
55  
Download from Www.Somanuals.com. All Manuals Search And Download.  
56  
3Com VCX V7111 Analog Gateway Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CHAPTER 8: REGULATORY INFORMATION  
V7111 FXS Regulatory Information  
Declaration of Conformity  
Application of Council Directives:  
73/23/EEC (including amendments),  
89/336/EEC (including amendments),  
Standards to which Conformity is Declared:  
EN55022: 1998, Class B  
EN55024:1998  
EN61000-3-2: 1995  
(including amendments A1: 1998, A2: 1998, A14: 2000)  
EN61000-3-3: 1995  
EN60950-1: 2001  
Manufacturer’s Name:  
Manufacturer’s Address:  
Type of Equipment:  
Model Numbers:  
:
3Com Ltd.  
1 Hayarden Street, Airport City, Lod 70151, Israel.  
Analog VoIP System.  
MP-112/ 2 FXS; MP-114/ 4 FXS; MP-118/ 8 FXS  
I, the undersigned, hereby declare that the equipment specified above conforms to the above Directives and Standards.  
11th February 2005  
Airport City, Lod, Israel  
Signature  
Date (Day/Month/Year)  
Location  
I. Zusmanovich, Compliance Engineering Manager  
Czech  
Danish  
Dutch  
[3Com Ltd] tímto prohlašuje, že tento [V7111/FXS series] je ve shodě se základními  
požadavky a dalšími příslušnými ustanoveními směrnice 89/336/EEC, 73/23/EEC.  
Undertegnede [3Com Ltd] erklærer herved, at følgende udstyr [V7111/FXS Series]  
overholder de væsentlige krav og øvrige relevante krav i direktiv 89/336/EEC, 73/23/EEC.  
Hierbij verklaart [3Com Ltd] dat het toestel [V7111/FXS Series] in overeenstemming is met  
de essentiële eisen en de andere relevante bepalingen van richtlijn 89/336/EEC,  
73/23/EEC  
English  
Hereby, [3Com Ltd], declares that this [V7111/FXS Series] is in compliance with the  
essential requirements and other relevant provisions of Directive 89/336/EEC, 73/23/EEC.  
Estonian  
Käesolevaga kinnitab [3Com Ltd] seadme [V7111/FXS Series] vastavust direktiivi  
89/336/EEC, 73/23/EEC põhinõuetele ja nimetatud direktiivist tulenevatele teistele  
asjakohastele sätetele.  
Finnish  
[3Com Ltd] vakuuttaa täten että [V7111/FXS Series] tyyppinen laite on direktiivin  
89/336/EEC, 73/23/EEC oleellisten vaatimusten ja sitä koskevien direktiivin muiden ehtojen  
mukainen.  
3Com VCX V7111 Analog Gateway Installation Guide  
57  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
French  
Par la présente [3Com Ltd] déclare que l'appareil [V7111/FXS Series] est conforme aux  
exigences essentielles et aux autres dispositions pertinentes de la directive 89/336/EEC,  
73/23/EEC  
German  
Greek  
Hiermit erklärt [3Com Ltd], dass sich dieser/diese/dieses [V7111/FXS Series] in  
Übereinstimmung mit den grundlegenden Anforderungen und den anderen relevanten  
Vorschriften der Richtlinie 89/336/EEC, 73/23/EEC befindet". (BMWi)  
ΜΕ ΤΗΝ ΠΑΡΟΥΣΑ [3Com Ltd] ΔΗΛΩΝΕΙ ΟΤΙ [V7111/FXS Series] ΣΥΜΜΟΡΦΩΝΕΤΑΙ  
ΠΡΟΣ ΤΙΣ ΟΥΣΙΩΔΕΙΣ ΑΠΑΙΤΗΣΕΙΣ ΚΑΙ ΤΙΣ ΛΟΙΠΕΣ ΣΧΕΤΙΚΕΣ ΔΙΑΤΑΞΕΙΣ ΤΗΣ  
ΟΔΗΓΙΑΣ 89/336/EEC, 73/23/EEC  
Hungarian  
Alulírott, [3Com Ltd] nyilatkozom, hogy a [V7111/FXS Series] megfelel a vonatkozó  
alapvetõ követelményeknek és az 89/336/EEC, 73/23/EEC irányelv egyéb elõírásainak  
Icelandic  
Italian  
æki þetta er í samræmi við tilskipun Evrópusambandsins 89/336/EEC, 73/23/EEC  
Con la presente [3Com Ltd] dichiara che questo (V7111/FXS Series) è conforme ai requisiti  
essenziali ed alle altre disposizioni pertinenti stabilite dalla direttiva 89/336/EEC,  
73/23/EEC.  
Latvian  
Ar šo [3Com Ltd] deklarē, ka [V7111/FXS Series] atbilst Direktīvas 89/336/EEC, 73/23/EEC  
būtiskajām prasībām un citiem ar to saistītajiem noteikumiem.  
Lithuanian  
Maltese  
[3Com Ltd] deklaruoja, kad irenginys [V7111/FXS Series] tenkina 89/336/EEC, 73/23/EEC  
Direktyvos esminius reikalavimus ir kitas sios direktyvos nuostatas  
Hawnhekk, [3Com Ltd], jiddikjara li dan [V7111/FXS Series] jikkonforma mal-ħtiġijiet  
essenzjali u ma provvedimenti oħrajn relevanti li hemm fid-Dirrettiva 89/336/EEC,  
73/23/EEC  
Norwegian  
Polish  
Dette produktet er i samhørighet med det Europeiske Direktiv 89/336/EEC, 73/23/EEC  
[3Com Ltd], deklarujemy z pelna odpowiedzialnoscia, ze wyrób [V7111/FXS Series] spelnia  
podstawowe wymagania i odpowiada warunkom zawartym w dyrektywie 89/336/EEC,  
73/23/EEC  
Portuguese [3Com Ltd] declara que este [V7111/FXS Series] está conforme com os requisitos  
essenciais e outras disposições da Directiva 89/336/EEC, 73/23/EEC.  
Slovak  
[3Com Ltd] týmto vyhlasuje, že [V7111/FXS Series] spĺňa základné požiadavky a všetky  
príslušné ustanovenia Smernice 89/336/EEC, 73/23/EEC.  
Slovene  
Spanish  
Šiuo [3Com Ltd] deklaruoja, kad šis [V7111/FXS Series] atitinka esminius reikalavimus ir  
kitas 89/336/EEC, 73/23/EEC Direktyvos nuostatas.  
Por medio de la presente [3Com Ltd] declara que el (V7111/FXS Series) cumple con los  
requisitos esenciales y cualesquiera otras disposiciones aplicables o exigibles de la  
Directiva 89/336/EEC, 73/23/EEC  
Swedish  
Härmed intygar [3Com Ltd] att denna [V7111/FXS Series] står I överensstämmelse med de  
väsentliga egenskapskrav och övriga relevanta bestämmelser som framgår av direktiv  
89/336/EEC, 73/23/EEC.  
58  
3Com VCX V7111 Analog Gateway Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Safety Notice  
Installation and service of this unit must only be performed by authorized, qualified service  
personnel. To avoid risk of fire use 26AWG or higher wiring to connect the FXS telecom  
ports.  
Telecommunication Safety  
The safety status of each port on the gateway is declared and detailed in the table below:  
Ports  
Safety Status  
SELV  
Ethernet (100 Base-TX)  
FXS  
TNV-3  
TNV-3: Circuit whose normal operating voltages exceeds the limits for an SELV circuit under  
normal operating conditions and on which over voltages from Telecommunication Networks  
are possible  
SELV: Safety extra low voltage circuit.  
FCC Statement  
This equipment has been tested and found to comply with the limits for a Class B digital  
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide  
reasonable protection against harmful interference in a residential installation. This  
equipment generates uses and can and can radiate radio frequency energy and, if not  
installed and used in accordance with the instructions, may cause harmful interference to  
radio communications. However there is no guarantee that interference will not occur in a  
particular installation. If this equipment does cause harmful interference to radio or television  
reception, which can be determined by turning the equipment off and on, the user is  
encouraged to try to correct the interference by one or more of the following measures:  
ƒ
ƒ
ƒ
Reorient or relocate the receiving antenna.  
Increase the separation between the equipment and receiver.  
Connect the equipment into an outlet on a circuit different from that to which the receiver  
is connected.  
ƒ
Consult the dealer or an experienced radio/TV technician for help.  
3Com VCX V7111 Analog Gateway Installation Guide  
59  
Download from Www.Somanuals.com. All Manuals Search And Download.  
V7111 FXO Regulatory Information  
Declaration of Conformity  
Application of Council Directives:  
73/23/EEC (including amendments),  
89/336/EEC (including amendments),  
1999/5/EC Annex-II of the Directive  
Standards to which Conformity is Declared:  
EN55022: 1998, Class B  
EN55024:1998  
EN61000-3-2: 1995  
(including amendments A1: 1998, A2: 1998, A14: 2000)  
EN61000-3-3: 1995  
EN60950-1: 2001  
TBR-21: 1998  
Manufacturer’s Name:  
Manufacturer’s Address:  
Type of Equipment:  
Model Numbers:  
3Com Ltd.  
1 Hayarden Street, Airport City, Lod 70151, Israel.  
Analog VoIP System.  
MP-112/ 2 FXO; MP-114 4 /FXO; MP-118/ 8 FXO  
I, the undersigned, hereby declare that the equipment specified above conforms to the above Directives and Standards.  
28th February 2006  
Airport City, Lod, Israel  
Signature  
Date (Day/Month/Year)  
Location  
I. Zusmanovich, Compliance Engineering Manager  
Czech  
[3Com Ltd] tímto prohlašuje, že tento [MP-1xx/FXO Series] je ve shodě se základními  
požadavky a dalšími příslušnými ustanoveními směrnice 1999/5/ES."  
Danish  
Dutch  
Undertegnede [3Com Ltd] erklærer herved, at følgende udstyr [MP-1xx/FXO Series]  
overholder de væsentlige krav og øvrige relevante krav i direktiv 1999/5/EF  
Hierbij verklaart [3Com Ltd] dat het toestel [MP-1xx/FXO Series] in overeenstemming is  
met de essentiële eisen en de andere relevante bepalingen van richtlijn 1999/5/EG  
English  
Estonian  
Hereby, [3Com Ltd], declares that this [MP-1xx/FXO Series] is in compliance with the  
essential requirements and other relevant provisions of Directive 1999/5/EC.  
Käesolevaga kinnitab [3Com Ltd] seadme [MP-1xx/FXO Series] vastavust direktiivi  
1999/5/EÜ põhinõuetele ja nimetatud direktiivist tulenevatele teistele asjakohastele  
sätetele.  
Finnish  
French  
German  
[3Com Ltd] vakuuttaa täten että [MP-1xx/FXO Series] tyyppinen laite on direktiivin  
1999/5/EY oleellisten vaatimusten ja sitä koskevien direktiivin muiden ehtojen mukainen.  
Par la présente [3Com Ltd] déclare que l'appareil [MP-1xx/FXO Series] est conforme aux  
exigences essentielles et aux autres dispositions pertinentes de la directive 1999/5/CE  
Hiermit erklärt [3Com Ltd], dass sich dieser/diese/dieses [MP-1xx/FXO Series] in  
Übereinstimmung mit den grundlegenden Anforderungen und den anderen relevanten  
Vorschriften der Richtlinie 1999/5/EG befindet". (BMWi)  
Greek  
ΜΕ ΤΗΝ ΠΑΡΟΥΣΑ [3Com Ltd] ΔΗΛΩΝΕΙ ΟΤΙ [MP-1xx/FXO Series] ΣΥΜΜΟΡΦΩΝΕΤΑΙ  
ΠΡΟΣ ΤΙΣ ΟΥΣΙΩΔΕΙΣ ΑΠΑΙΤΗΣΕΙΣ ΚΑΙ ΤΙΣ ΛΟΙΠΕΣ ΣΧΕΤΙΚΕΣ ΔΙΑΤΑΞΕΙΣ ΤΗΣ  
ΟΔΗΓΙΑΣ 1999/5/ΕΚ  
60  
3Com VCX V7111 Analog Gateway Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hungarian  
Alulírott, [3Com Ltd] nyilatkozom, hogy a [MP-1xx/FXO Series] megfelel a vonatkozó  
alapvetõ követelményeknek és az 1999/5/EC irányelv egyéb elõírásainak  
Icelandic  
Italian  
æki þetta er í samræmi við tilskipun Evrópusambandsins 1999/5  
Con la presente [3Com Ltd] dichiara che questo [MP-1xx/FXO Series] è conforme ai  
requisiti essenziali ed alle altre disposizioni pertinenti stabilite dalla direttiva 1999/5/CE.  
Latvian  
Ar šo [3Com Ltd] deklarē, ka [MP-1xx/FXO Series] atbilst Direktīvas 1999/5/EK būtiskajām  
prasībām un citiem ar to saistītajiem noteikumiem.  
Lithuanian  
Maltese  
[3Com Ltd] deklaruoja, kad irenginys [MP-1xx/FXO Series] tenkina 1999/5/EB Direktyvos  
esminius reikalavimus ir kitas sios direktyvos nuostatas  
Hawnhekk, [3Com Ltd], jiddikjara li dan [MP-1xx/FXO Series] jikkonforma mal-ħtiġijiet  
essenzjali u ma provvedimenti oħrajn relevanti li hemm fid-Dirrettiva 1999/5/EC  
Norwegian  
Polish  
Dette produktet er i samhørighet med det Europeiske Direktiv 1999/5  
[3Com Ltd], deklarujemy z pelna odpowiedzialnoscia, ze wyrób [MP-1xx/FXO Series]  
spelnia podstawowe wymagania i odpowiada warunkom zawartym w dyrektywie 1999/5/EC  
Portuguese [3Com Ltd] declara que este [MP-1xx/FXO Series] está conforme com os requisitos  
essenciais e outras disposições da Directiva 1999/5/CE.  
Slovak  
[3Com Ltd] týmto vyhlasuje, že [MP-1xx/FXO Series] spĺňa základné požiadavky a všetky  
príslušné ustanovenia Smernice 1999/5/ES.  
Slovene  
Spanish  
Šiuo [3Com Ltd] deklaruoja, kad šis [MP-1xx/FXO Series] atitinka esminius reikalavimus ir  
kitas 1999/5/EB Direktyvos nuostatas.  
Por medio de la presente [3Com Ltd] declara que el [MP-1xx/FXO Series] cumple con los  
requisitos esenciales y cualesquiera otras disposiciones aplicables o exigibles de la  
Directiva 1999/5/CE  
Swedish  
Härmed intygar [3Com Ltd] att denna [MP-1xx/FXO Series] står I överensstämmelse med  
de väsentliga egenskapskrav och övriga relevanta bestämmelser som framgår av direktiv  
1999/5/EG.  
Safety Notice  
Installation and service of this unit must only be performed by authorized, qualified service  
personnel. To avoid risk of fire use 26AWG or higher wiring to connect the FXO telecom  
ports.  
Industry Canada Notice  
This equipment meets the applicable Industry Canada Terminal Equipment technical  
specifications. This is confirmed by the registration numbers. The abbreviation, IC, before the  
registration number signifies that registration was performed based on a declaration of  
conformity indicating that Industry Canada technical specifications were met. It does not  
imply that Industry Canada approved the equipment.  
3Com VCX V7111 Analog Gateway Installation Guide  
61  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FXO Only: The Ringer Equivalence Number (REN) for this terminal is 0.5. The REN  
assigned to each terminal equipment provides an indication of the maximum number of  
terminals allowed to be connected to a telephone interface. The termination on an interface  
may consist of any combination of devices subject only to the requirement that the sum of  
Ringer Equivalence Number of all devices do not exceed five.  
Network Compatibility  
The products support the Telecom networks in EU that comply with TBR21.  
Telecommunication Safety  
The safety status of each port is declared and detailed in the table below:  
Ports  
Safety Status  
SELV  
Ethernet (100 Base-T)  
FXO  
TNV-3  
TNV-3: Circuit whose normal operating voltages exceeds the limits for an SELV circuit under  
normal operating conditions and on which over voltages from Telecommunication Networks  
are possible.  
SELV: Safety extra low voltage circuit.  
MP-1xx FXO Notice  
The V7111 FXO Output Tones and DTMF level should not exceed -9 dBm (3Com setting  
#23) in order to comply with FCC 68, TIA/EIA/IS-968 and TBR-21.  
The maximum allowed gain between any 2 ports connected to the PSTN should be set to 0  
dB in order to comply with FCC 68, TIA/EIA/IS-968 Signal power limitation  
FCC Statement  
This equipment has been tested and found to comply with the limits for a Class B digital  
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide  
reasonable protection against harmful interference in a residential installation. This  
equipment generates, uses and can radiate radio frequency energy and, if not installed and  
used in accordance with the instructions, may cause harmful interference to radio  
communications. However there is no guarantee that interference will not occur in a  
particular installation. If this equipment does cause harmful interference to radio or television  
reception, which can be determined by turning the equipment off and on, the user is  
encouraged to try to correct the interference by one or more of the following measures:  
ƒ
ƒ
Reorient or relocate the receiving antenna.  
Increase the separation between the equipment and receiver.  
62  
3Com VCX V7111 Analog Gateway Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ƒ
ƒ
Connect the equipment into an outlet on a circuit different from that to which the receiver  
is connected.  
Consult the dealer or an experienced radio/TV technician for help.  
3Com VCX V7111 Analog Gateway Installation Guide  
63  
Download from Www.Somanuals.com. All Manuals Search And Download.  
V7111 FXS +FXO Regulatory Information  
Declaration of Conformity  
Application of Council Directives:  
73/23/EEC (including amendments),  
89/336/EEC (including amendments),  
1999/5/EC Annex-II of the Directive  
Standards to which Conformity is Declared:  
EN55022: 1998, Class B  
EN55024:1998  
EN61000-3-2: 1995  
(including amendments A1: 1998, A2: 1998, A14: 2000)  
EN61000-3-3: 1995  
EN60950-1: 2001  
TBR-21: 1998  
Manufacturer’s Name:  
Manufacturer’s Address:  
Type of Equipment:  
Model Numbers:  
3Com Ltd.  
1 Hayarden Street, Airport City, Lod 70151, Israel.  
Analog VoIP System.  
MP-114/ 2FXS+2FXO (MP-114/2 FXS / 2 FXO / AC)  
MP-118/ 4FXS+4FXO (MP-118/4 FXS / 4 FXO / AC)  
I, the undersigned, hereby declare that the equipment specified above conforms to the above Directives and Standards.  
28th February 2006  
Airport City, Lod, Israel  
Date (Day/Month/Year) Location  
Signature  
I. Zusmanovich, Compliance Engineering Manager  
Czech  
[3Com Ltd] tímto prohlašuje, že tento [V7111/FXS-FXO series] je ve shodě se základními  
požadavky a dalšími příslušnými ustanoveními směrnice 89/336/EEC, 73/23/EEC;  
1999/5/ES.  
Danish  
Dutch  
Undertegnede [3Com Ltd] erklærer herved, at følgende udstyr [V7111/FXS-FXO Series]  
overholder de væsentlige krav og øvrige relevante krav i direktiv 89/336/EEC, 73/23/EEC;  
1999/5/ES.  
Hierbij verklaart [3Com Ltd] dat het toestel [V7111/FXS-FXO Series] in overeenstemming is  
met de essentiële eisen en de andere relevante bepalingen van richtlijn 89/336/EEC,  
73/23/EEC; 1999/5/ES  
English  
Estonian  
Finnish  
French  
Hereby, [3Com Ltd], declares that this [V7111/FXS-FXO Series] is in compliance with the  
essential requirements and other relevant provisions of Directive 89/336/EEC, 73/23/EEC;  
1999/5/ES.  
Käesolevaga kinnitab [3Com Ltd] seadme [V7111/FXS-FXO Series] vastavust direktiivi  
89/336/EEC, 73/23/EEC; 1999/5/ES põhinõuetele ja nimetatud direktiivist tulenevatele  
teistele asjakohastele sätetele.  
[3Com Ltd] vakuuttaa täten että [V7111/FXS-FXO Series] tyyppinen laite on direktiivin  
89/336/EEC, 73/23/EEC; 1999/5/ES oleellisten vaatimusten ja sitä koskevien direktiivin  
muiden ehtojen mukainen.  
Par la présente [3Com Ltd] déclare que l'appareil [V7111/FXS-FXO Series] est conforme  
aux exigences essentielles et aux autres dispositions pertinentes de la directive  
89/336/EEC, 73/23/EEC; 1999/5/ES  
64  
3Com VCX V7111 Analog Gateway Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
German  
Greek  
Hiermit erklärt [3Com Ltd], dass sich dieser/diese/dieses [V7111/FXS-FXO Series] in  
Übereinstimmung mit den grundlegenden Anforderungen und den anderen relevanten  
Vorschriften der Richtlinie 89/336/EEC, 73/23/EEC; 1999/5/ES befindet". (BMWi)  
ΜΕ ΤΗΝ ΠΑΡΟΥΣΑ [3Com Ltd] ΔΗΛΩΝΕΙ ΟΤΙ [V7111/FXS-FXO Series]  
ΣΥΜΜΟΡΦΩΝΕΤΑΙ ΠΡΟΣ ΤΙΣ ΟΥΣΙΩΔΕΙΣ ΑΠΑΙΤΗΣΕΙΣ ΚΑΙ ΤΙΣ ΛΟΙΠΕΣ ΣΧΕΤΙΚΕΣ  
ΔΙΑΤΑΞΕΙΣ ΤΗΣ ΟΔΗΓΙΑΣ 89/336/EEC, 73/23/EEC; 1999/5/ES  
Hungarian  
Alulírott, [3Com Ltd] nyilatkozom, hogy a [V7111/FXS-FXO Series] megfelel a vonatkozó  
alapvetõ követelményeknek és az 89/336/EEC, 73/23/EEC; 1999/5/ES irányelv egyéb  
elõírásainak  
Icelandic  
Italian  
æki þetta er í samræmi við tilskipun Evrópusambandsins 89/336/EEC, 73/23/EEC;  
1999/5/ES  
Con la presente [3Com Ltd] dichiara che questo [V7111/FXS-FXO Series] è conforme ai  
requisiti essenziali ed alle altre disposizioni pertinenti stabilite dalla direttiva 89/336/EEC,  
73/23/EEC; 1999/5/ES.  
Latvian  
Ar šo [3Com Ltd] deklarē, ka [V7111/FXS-FXO Series] atbilst Direktīvas 89/336/EEC,  
73/23/EEC; 1999/5/ES būtiskajām prasībām un citiem ar to saistītajiem noteikumiem.  
Lithuanian  
Maltese  
[3Com Ltd] deklaruoja, kad irenginys [V7111/FXS-FXO Series] tenkina 89/336/EEC,  
73/23/EEC; 1999/5/ES Direktyvos esminius reikalavimus ir kitas sios direktyvos nuostatas  
Hawnhekk, [3Com Ltd], jiddikjara li dan [V7111/FXS-FXO Series] jikkonforma mal-ħtiġijiet  
essenzjali u ma provvedimenti oħrajn relevanti li hemm fid-Dirrettiva 89/336/EEC,  
73/23/EEC; 1999/5/ES  
Norwegian  
Polish  
Dette produktet er i samhørighet med det Europeiske Direktiv 89/336/EEC, 73/23/EEC;  
1999/5/ES  
[3Com Ltd], deklarujemy z pelna odpowiedzialnoscia, ze wyrób [V7111/FXS-FXO Series]  
spelnia podstawowe wymagania i odpowiada warunkom zawartym w dyrektywie  
89/336/EEC, 73/23/EEC; 1999/5/ES  
Portuguese [3Com Ltd] declara que este [V7111/FXS-FXO Series] está conforme com os requisitos  
essenciais e outras disposições da Directiva 89/336/EEC, 73/23/EEC; 1999/5/ES.  
Slovak  
[3Com Ltd] týmto vyhlasuje, že [V7111/FXS-FXO Series] spĺňa základné požiadavky a  
všetky príslušné ustanovenia Smernice 89/336/EEC, 73/23/EEC; 1999/5/ES.  
Slovene  
Spanish  
Šiuo [3Com Ltd] deklaruoja, kad šis [V7111/FXS-FXO Series] atitinka esminius  
reikalavimus ir kitas 89/336/EEC, 73/23/EEC; 1999/5/ES Direktyvos nuostatas.  
Por medio de la presente [3Com Ltd] declara que el [V7111/FXS-FXO Series] cumple con  
los requisitos esenciales y cualesquiera otras disposiciones aplicables o exigibles de la  
Directiva 89/336/EEC, 73/23/EEC; 1999/5/ES  
Swedish  
Härmed intygar [3Com Ltd] att denna [V7111/FXS-FXO Series] står I överensstämmelse  
med de väsentliga egenskapskrav och övriga relevanta bestämmelser som framgår av  
direktiv 89/336/EEC, 73/23/EEC; 1999/5/ES.  
Safety Notice  
Installation and service of this unit must only be performed by authorized, qualified service  
personnel. To avoid risk of fire use 26AWG or higher wiring to connect the FXS or FXO  
telecom ports.  
3Com VCX V7111 Analog Gateway Installation Guide  
65  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Telecommunications Safety  
The safety status of each port on the gateway is declared and detailed in the table below:  
Ports  
Safety Status  
SELV  
Ethernet (100 Base-T)  
FXS  
FXO  
TNV-3  
TNV-3  
TNV-3: Circuit whose normal operating voltages exceeds the limits for an SELV circuit under  
normal operating conditions and on which over voltages from Telecommunication Networks  
are possible.  
SELV: Safety extra low voltage circuit.  
FCC Statement  
This equipment has been tested and found to comply with the limits for a Class B digital  
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide  
reasonable protection against harmful interference in a residential installation. This  
equipment generates uses and can and can radiate radio frequency energy and, if not  
installed and used in accordance with the instructions, may cause harmful interference to  
radio communications. However there is no guarantee that interference will not occur in a  
particular installation. If this equipment does cause harmful interference to radio or television  
reception, which can be determined by turning the equipment off and on, the user is  
encouraged to try to correct the interference by one or more of the following measures:  
ƒ
ƒ
ƒ
Reorient or relocate the receiving antenna.  
Increase the separation between the equipment and receiver.  
Connect the equipment into an outlet on a circuit different from that to which the receiver  
is connected.  
ƒ
Consult the dealer or an experienced radio/TV technician for help.  
66  
3Com VCX V7111 Analog Gateway Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
V7111 24-PORT  
Declaration of Conformity  
Application of Council Directives:  
73/23/EEC (including amendments),  
89/336/EEC (including amendments),  
Standards to which Conformity is Declared:  
EN55022: 1998, Class A  
EN55024:1998  
EN61000-3-2: 1995  
(including amendments A1: 1998, A2: 1998, A14: 2000)  
EN61000-3-3: 1995  
EN60950: 1992 Including amendments 1,2,3,4 and 11  
Manufacturer’s Name:  
Manufacturer’s Address:  
Type of Equipment:  
Model Numbers:  
3Com Ltd.  
1 Hayarden Street, Airport City, Lod 70151, Israel.  
Analog VoIP System.  
MP-124/FXS  
I, the undersigned, hereby declare that the equipment specified above conforms to the above Directives and Standards.  
11th February, 2005  
Airport City, Lod, Israel  
Signature  
Date (Day/Month/Year)  
Location  
I. Zusmanovich, Compliance Engineering Manager  
Czech  
Danish  
Dutch  
[3Com Ltd] tímto prohlašuje, že tento [V7111 24-PORT] je ve shodě se základními  
požadavky a dalšími příslušnými ustanoveními směrnice 89/336/EEC, 73/23/EEC.  
Undertegnede [3Com Ltd] erklærer herved, at følgende udstyr [V7111 24-PORT]  
overholder de væsentlige krav og øvrige relevante krav i direktiv 89/336/EEC, 73/23/EEC.  
Hierbij verklaart [3Com Ltd] dat het toestel [V7111 24-PORT] in overeenstemming is met  
de essentiële eisen en de andere relevante bepalingen van richtlijn 89/336/EEC,  
73/23/EEC  
English  
Hereby, [3Com Ltd], declares that this [V7111 24-PORT] is in compliance with the essential  
requirements and other relevant provisions of Directive 89/336/EEC, 73/23/EEC.  
Estonian  
Käesolevaga kinnitab [3Com Ltd] seadme [V7111 24-PORT] vastavust direktiivi  
89/336/EEC, 73/23/EEC põhinõuetele ja nimetatud direktiivist tulenevatele teistele  
asjakohastele sätetele.  
Finnish  
French  
German  
[3Com Ltd] vakuuttaa täten että [V7111 24-PORT] tyyppinen laite on direktiivin  
89/336/EEC, 73/23/EEC oleellisten vaatimusten ja sitä koskevien direktiivin muiden ehtojen  
mukainen.  
Par la présente [3Com Ltd] déclare que l'appareil [V7111 24-PORT] est conforme aux  
exigences essentielles et aux autres dispositions pertinentes de la directive 89/336/EEC,  
73/23/EEC  
Hiermit erklärt [3Com Ltd], dass sich dieser/diese/dieses [V7111 24-PORT] in  
Übereinstimmung mit den grundlegenden Anforderungen und den anderen relevanten  
Vorschriften der Richtlinie 89/336/EEC, 73/23/EEC befindet". (BMWi)  
3Com VCX V7111 Analog Gateway Installation Guide  
67  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Greek  
ΜΕ ΤΗΝ ΠΑΡΟΥΣΑ [3Com Ltd] ΔΗΛΩΝΕΙ ΟΤΙ [V7111 24-PORT] ΣΥΜΜΟΡΦΩΝΕΤΑΙ  
ΠΡΟΣ ΤΙΣ ΟΥΣΙΩΔΕΙΣ ΑΠΑΙΤΗΣΕΙΣ ΚΑΙ ΤΙΣ ΛΟΙΠΕΣ ΣΧΕΤΙΚΕΣ ΔΙΑΤΑΞΕΙΣ ΤΗΣ  
ΟΔΗΓΙΑΣ 89/336/EEC, 73/23/EEC  
Hungarian  
Alulírott, [3Com Ltd] nyilatkozom, hogy a [V7111 24-PORT] megfelel a vonatkozó alapvetõ  
követelményeknek és az 89/336/EEC, 73/23/EEC irányelv egyéb elõírásainak  
Icelandic  
Italian  
æki þetta er í samræmi við tilskipun Evrópusambandsins 89/336/EEC, 73/23/EEC  
Con la presente [3Com Ltd] dichiara che questo [V7111 24-PORT] è conforme ai requisiti  
essenziali ed alle altre disposizioni pertinenti stabilite dalla directiva 89/336/EEC,  
73/23/EEC.  
Latvian  
Ar šo [3Com Ltd] deklarē, ka [V7111 24-PORT] atbilst Direktīvas 89/336/EEC, 73/23/EEC  
būtiskajām prasībām un citiem ar to saistītajiem noteikumiem.  
Lithuanian  
Maltese  
[3Com Ltd] deklaruoja, kad irenginys [V7111 24-PORT] tenkina 89/336/EEC, 73/23/EEC  
Direktyvos esminius reikalavimus ir kitas sios direktyvos nuostatas  
Hawnhekk, [3Com Ltd], jiddikjara li dan [V7111 24-PORT] jikkonforma mal-ħtiġijiet  
essenzjali u ma provvedimenti oħrajn relevanti li hemm fid-Dirrettiva 89/336/EEC,  
73/23/EEC  
Norwegian  
Polish  
Dette produktet er i samhørighet med det Europeiske Direktiv 89/336/EEC, 73/23/EEC  
[3Com Ltd], deklarujemy z pelna odpowiedzialnoscia, ze wyrób [V7111 24-PORT] spelnia  
podstawowe wymagania i odpowiada warunkom zawartym w dyrektywie 89/336/EEC,  
73/23/EEC  
Portuguese [3Com Ltd] declara que este [V7111 24-PORT] está conforme com os requisitos essenciais  
e outras disposições da Directiva 89/336/EEC, 73/23/EEC.  
Slovak  
[3Com Ltd] týmto vyhlasuje, že [V7111 24-PORT Series] spĺňa základné požiadavky a  
všetky príslušné ustanovenia Smernice 89/336/EEC, 73/23/EEC.  
Slovene  
Spanish  
Šiuo [3Com Ltd] deklaruoja, kad šis [V7111 24-PORT Series] atitinka esminius  
reikalavimus ir kitas 89/336/EEC, 73/23/EEC Direktyvos nuostatas.  
Por medio de la presente [3Com Ltd] declara que el [V7111 24-PORT Series] cumple con  
los requisitos esenciales y cualesquiera otras disposiciones aplicables o exigibles de la  
Directiva 89/336/EEC, 73/23/EEC  
Swedish  
Härmed intygar [3Com Ltd] att denna [V7111 24-PORT Series] står I överensstämmelse  
med de väsentliga egenskapskrav och övriga relevanta bestämmelser som framgår av  
direktiv 89/336/EEC, 73/23/EEC.  
Safety Notice  
Installation and service of this unit must only be performed by authorized, qualified service  
personnel.  
The protective earth terminal on the back of the V7111 24-PORT must be permanently  
connected to protective earth.  
68  
3Com VCX V7111 Analog Gateway Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Telecommunication Safety  
The safety status of each port on the gateway is declared and detailed in the table below:  
Ports  
Safety Status  
SELV  
Ethernet (100 Base-TX)  
FXS (ODP P/N’s)  
FXS  
TNV-3  
TNV-2  
TNV-3: Circuit whose normal operating voltages exceeds the limits for an SELV circuit under  
normal operating conditions and on which over voltages from Telecommunication Networks  
are possible  
TNV-2: Circuit whose normal operating voltages exceeds the limits for an SELV circuit under  
normal operating conditions and is not subjected to over voltages from Telecommunication  
Networks  
SELV: Safety extra low voltage circuit.  
FCC Statement  
This equipment has been tested and found to comply with the limits for a Class A digital  
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide  
reasonable protection against harmful interference when the equipment is operated in a  
commercial environment. This equipment generates uses and can radiate radio frequency  
energy and, if not installed and used in accordance with the instruction manual, may cause  
harmful interference to radio communications. Operation of this equipment in a residential  
area is likely to cause harmful interference in which case the user will be required to correct  
the interference at his own expense.  
This is a Class A product. In a domestic environment this product may cause radio  
interference in which case the user may be required to take adequate measures.  
3Com VCX V7111 Analog Gateway Installation Guide  
69  
Download from Www.Somanuals.com. All Manuals Search And Download.  
70  
3Com VCX V7111 Analog Gateway Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OBTAINING SUPPORT FOR YOUR 3COM  
PRODUCT  
Customer Support  
Customer technical support and service are provided by 3Com’ Distributors, Partners, and  
Resellers from whom the product was purchased. For Customer support for products  
purchased directly from 3Com, contact [email protected].  
3Com VCX V7111 Analog Gateway Installation Guide  
71  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 

Acoustic Research Car Speaker AW553 User Manual
Acumen Heart Rate Monitor Ergo Pro User Manual
AGFA Automobile Accessories ATCA C110 1G User Manual
Aiphone Film Camera GFK PS User Manual
Allied Telesis Switch 48W User Manual
American Standard Plumbing Product 705205 User Manual
AMX Stereo Amplifier AVB DA RGBHV HD15 0106 User Manual
Axis Communications Security Camera M2014 E User Manual
Axor Plumbing Product 06573000 User Manual
Barco Camera Accessories R9864220 User Manual