Low Profile SATA RAID
2 Port PCI Host
User Manual
English
LINDY No. 70540
www.LINDY.com
© LINDY ELECTRONICS LIMITED & LINDY-ELEKTRONIK GMBH
-
FIRST EDITION (November 2004)
Dual high speed Serial ATA interface ports, each supporting 1st generation
Serial ATA data rates (1.5Gb/s).
Provides RAID 0 (Stripping) to greatly increase the performance of data
transfer by simultaneously writing data to 2 drives.
Provides RAID 1 (Mirroring) to protect the data from a disk failure by writing
identical data on 2 drives.
Fully compliant with Serial ATA 1.0 specifications.
Supports Spread Spectrum in receiver.
Independent 256-byte FIFOs (32 bit * 64 deep) per Serial ATA channel for host
reads and writes.
1.2. Package Contents
Low Profile SATA RAID 2 Port PCI Host Adapter
This Users Manual
Driver Diskette
Regular Size PCI Bracket
2. What Is RAID
RAID - Redundant Array of Independent Disks
RAID technology manages multiple disk drives to enhance I/O performance and provide
redundancy in order to withstand the failure of any individual member, without loss of
data. This card provides two RAID Set types, Striped (RAID 0) and Mirrored (RAID 1).
Disk Striping (RAID 0)
Striping is a performance-oriented, non-redundant data mapping technique. While Striping
is discussed as a RAID Set type, it is actually does not provide fault tolerance. With
modern SATA bus mastering technology, multiple I/O operations can be done in parallel,
enhancing performance. Striping arrays use multiple disks to form a larger virtual disk.
Disk Mirroring (RAID 1)
Disk mirroring creates an identical twin for a selected disk by having the data simultaneously
written to two disks. This redundancy provides instantaneous protection from a single disk
- 3 -
failure. If a read failure occurs on one drive, the system reads the data from the other
drive.
3. BIOS Installation ( RAID Setting )
Creating and deleting RAID sets is a function found in the BIOS. During boot up, the RAID
setting message will appear and pause for a few moments to allow the user to choose what
to do. This board will act as normal NON-RAID card when BIOS not configured for RAID.
Just proceed to Software Installation section directly. If you use traditional parallel ATA
HDD, make sure your hard drives be set up as master mode before the RAID setting.
3.1. Creating Striped Sets (RAID 0)
1. As the BIOS boots, Press CTRL+S or F4 to enter the raid bios utility.
2. Select Create RAID set. Press Enter.
3. Select Stripe then press Enter.
4. Select Auto configuration. Press Enter.
5. Press Y to save your settings.
6. Press CTRL+E and then press Y to exit the setup.
7. Continue with conventional Fdisk and Format steps as if you are installing a conventional
hard drive.
8. Your RAID configuration is complete. Please proceed to software installation section.
3.2. Creating Mirrored Sets (RAID 1)
1. As the BIOS boots, Press CTRL+S or F4 to enter the raid bios utility.
2. Select Create RAID set. Press Enter.
3. Select Mirrored then press Enter.
4. Select Auto configuration. Press Enter.
5. Press Y to save your settings.
6. Press CTRL+E and then press Y to exit the setup.
7. Continue with conventional Fdisk and Format steps as if you are installing a conventional
hard drive.
8.Your RAID configuration is complete. Please proceed to software installation section.
- 4 -
3.3. Deleting RAID Sets
1. As the BIOS boots, Press CTRL+S or F4 to enter the raid bios utility.
2. Select Delete RAID set. Press Enter.
3. Answer Y to remove the RAID set. If the RAID set being deleted is a Striped set, then all of
the data will be lost. If the set being deleted is a Mirrored set, then the data will remain
intact and accessible on both drives.
3.4. Rebuilding Mirrored Sets
1. After replacing the failed hard drives boot the BIOS, Press CTRL+S or F4 to enter the
raid bios utility.
2. Select rebuilding Mirrored set. Press Enter.
3. Select Online rebuild or Offline rebuild.
4. Answer Y to rebuild the Mirrored set of hard drive.
3.5. Resolving Conflict
When a RAID set is created, the metadata written to the disk includes drive connection
information (Primary and Secondary). If, after a disk failure, the replacement disk was
previously part of a RAID set (or used in another system), it may have conflicting
metadata, specifically in reference to the drive connection information. If so, this
will prohibit the RAID set from being either created or rebuilt, In order for the RAID set
to function properly, this old metadata must be first overwritten with the new metadata.
To resolve this, select Resolve Conflicts, and the correct metadata, including the correct
drive connection information, will be written to the replacement disk.
4. Software Installation
This section provides the information on how to install the drivers of Low Profile SATA RAID
2 Port PCI Host Adapter for the operating systems:
New & Existing Windows 98/98 SE
New & Existing Windows ME
New & Existing Windows NT 4.0
New & Existing Windows 2000
New & Existing Windows XP
- 5 -
4.1. Windows 98/98SE Driver Installation
For New Windows 98/98 SE Systems
1. After the SATA RAID PCI Host Adapter and attached drives are configured, follow
Microsoft procedures to install Windows accordingly.
2. Once Windows has been installed, double click My Computer/Control
Panel/System, then click Device Manager.
3. Double click Other Devices then PCI RAID Controller.
4. Click Driver tab, then Update Driver.
5. Insert the Driver diskette and click Next.
6. Select Search for a better driver than the one ...option and click Next.
7. Check Specify a location, uncheck the other boxes, type in A:\ and click Next.
Click Next and then Finish.
8. Remove the Driver diskette and click Yes to restart Windows to complete driver
installation.
For Existing Windows 98/98 SE Systems
1. After the SATA RAID PCI Host Adapter and attached drives are configured, boot up
Windows.
2. At the Add New Hardware Wizard, click Next.
3. Select Search for the best driver for your device option and then click Next.
4. Insert the Driver diskette, check Specify a location, uncheck the other boxes, type
in A:\, and click Next.
5. Click Next and then Finish respectively.
4.2. Windows ME Driver Installation
For New Windows ME Systems
1. After the SATA RAID PCI Host Adapter and attached drives are configured, follow
Microsoft procedures to install Windows accordingly.
2. Once Windows has been installed, click My Computer, then click Properties. Click Device
Manager tab.
3. Double click Other Devices then PCI RAID Controller.
4. Click Driver tab, then Update Driver.
5. Insert the Driver diskette, check Specify the location of the driver (advanced)
and click Next.
6. Select Search for the better driver option, check Specify a location, uncheck
Removable Media, type in A:\, and click Next.
7. Click Next and then Finish.
- 6 -
8. Remove the Driver diskette and click Yes to restart Windows to complete driver
installation.
For Existing Windows ME Systems
1. After the SATA RAID PCI Host Adapter and attached drives are configured, boot up
Windows.
2. At the Add New Hardware Wizard, check Specify the location of the driver
(advanced), and click Next.
3. Insert the Driver diskette, check Specify a location, uncheck the other boxes, type
in A:\, and click Next.
4. Click Next and then Finish.
Verification of the Proper Installation for Windows 98/98SE/ME
1. Double click My Computer/Control Panel/System. Click Device Manager tab.
2. Double click SCSI Controllers, Silicon Image Sil-3112 SATA Raid Controller
should be listed.
3. Highlight Silicon Image Sil-3112 SATA Raid Controller and click Properties.
A message This device is working properly is displayed in the dialog box, the driver
has been correctly installed. If any error message is displayed, remove Silicon Image
Sil-3112 SATA Raid Controller and restart your system.
4.3. Windows NT 4.0 Driver Installation
For New Windows NT 4.0 System
1. After the SATA RAID PCI Host Adapter and attached drives are configured, follow
Microsoft procedures to install Windows accordingly.
2. At the Windows Set-up screen, press F6 to specify and add the driver.
3. Press S, select Other, then press Enter.
4. Insert the Driver diskette and press Enter.
5. Select Silicon Image Sil-3112 SATA Raid Controller Driver and press Enter.
6. Press Enter to continue and follow on-screen instructions to complete Windows NT
4.0 installation.
Add Windows NT 4.0 Driver on Original Booting Device
1. After the SATA RAID PCI Host Adapter and attached drives are configured, boot up
Windows. Double click My Computer/Control Panel/SCSI Adapters, then click the Drivers
tab.
2. Click Add… then Have Disk....
3. Insert the Driver diskette into the floppy drive and type in A:\, then click OK.
4. Highlight Silicon Image Sil-3112 SATA Raid Controller and click OK.
- 7 -
Verification of the Proper Installation for Windows NT 4.0
1. Double click My Computer/Control Panel/SCSI Adapters.
2. Highlight Silicon Image Sil-3112 SATA Raid Controller and click Properties.
This device is working properly is displayed in the dialog box, the driver has been
correctly installed.
4.4. Windows 2000 Driver Installation
For New Windows 2000 Systems
1. After the SATA RAID PCI Host Adapter and attached drives are configured, follow
Microsoft procedures to install Windows accordingly.
2. At the Windows Set-up screen, press F6 to specify and add the driver.
3. Insert the Driver diskette. Press S, then press Enter.
4. Select Silicon Image Sil-3112 SATA Raid Controller Driver and press Enter.
5. Press Enter to continue and follow on-screen instructions to complete installation.
Add Windows 2000 Driver on Original Booting Device
1. After the SATA RAID PCI Host Adapter and attached drives are configured, boot up
Windows.
2. At the Found New Hardware Wizard, click Next.
3. Select Search for a suitable driver for my device (recommended) and click Next.
4. Insert the Driver diskette into the floppy drive, check Specify a location, uncheck the
other boxes, click Next, type in A:\. Click OK and then Next to continue.
5. If the Digital Signature Not Found message appears, click Yes. (Note If prompted for
Windows 2000 CD-ROM, insert the CD and click OK. Type in D:\I386, click OK and
Finish. (assuming D: is your CD-ROM drive))
6. Click Finish.
4.5. Windows XP Driver Installation
For New Windows XP Systems
1. After the SATA RAID PCI Host Adapter and attached drives are configured, follow
Microsoft procedures to install Windows accordingly.
2. At the Windows Set-up screen, press F6 in order to specify and add the driver.
3. Insert the Driver diskette. Press S then press Enter.
4. Select Silicon Image Sil-3112 SATA Raid Controller Driver and press Enter.
5. Press Enter to continue and follow on-screen instructions to complete Windows XP
- 8 -
installation. Note: When the Software Installation warning pops up, click Yes. And
when the Hardware Installation warning pops up, click Yes again.
Add Windows XP Driver on Original Booting Device
1. After the SATA RAID PCI Host Adapter and attached drives are configured, boot up
Windows.
2. At the Found New Hardware Wizard, check Install from a list or specific
location (advanced), then click Next.
3. Insert the Driver diskette. Check Include this location in the search, uncheck the
other box, type in A:\, and click Next.
4. When a warning message pops up, click Continue Anyway, then click Finish.
Verification of the Proper Installation for Windows 2000/XP
1. Double click My Computer/Control Panel/System.
2. Click Hardware then click Device Manager.
3. Double click SCSI and RAID Controllers, then double click Silicon Image Sil-3112
SATA Raid Controller to display driver properties.
4. A message This device is working properly is displayed in the dialog box, the
driver has been correctly installed.
- 9 -
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) this device may not cause harmful interference,
and (2) this device must accept any interference
received, including interference that may cause
undesired operations.
- 10 -
|