QuickSpecs
Overview
HP BladeSystem c3000 Enclosure
HP BladeSystem c3000 Enclosure – Tower – Front View
1. Device Bays 1 thru 8
2. Enclosure DVD Drive
3. Standby Onboard Administrator (reserved for Future)
4. Insight Display
5. Active Onboard Administrator
HP BladeSystem c3000 Enclosure – Tower – Rear View
1.
2.
3.
4.
5.
6.
7.
8.
9.
Local KVM interface
Interconnect Bay 1
Active Cool Fans
Interconnect Bay 2
Enclosure Up-link and Service Port
Enclosure Down-link
iLO/Onboard Administrator Port
iLO/Onboard Administrator Port 2 (reserved for future)
Power Supplies
10. Interconnect Bay 4
11. Interconnect Bay 3
HP BladeSystem c3000 Enclosure – Rack – Front View
1. Device Bays 1 thru 8
2. Enclosure DVD Drive
3. Standby Onboard Administrator (reserved for Future)
4. Insight Display
HP BladeSystem c3000 Enclosure – Rack – Rear View
1.
2.
3.
4.
Local KVM interface
Interconnect Bay 1
Active Cool Fans
Interconnect Bay 2
DA - 12790
Worldwide — Version 12 — July 14, 2008
Page 1
QuickSpecs
Overview
HP BladeSystem c3000 Enclosure
Up to 8 half-height server blades (examples: HP ProLiant BL 260c G5, BL2x220c, BL460c, BL465c, BL465c G5 Server
Blade)
Up to 4 full-height server blades (Examples: HP ProLiant BL480c, BL 680c G5, BL685c, BL685c G5 Server Blades)
Up to 4 HP SB40c Storage blades attached to half-height server blades
Up to 4 PCI Expansion blades attached to half-height server blades
Or combinations of the above.
For additional server & storage blade information, please visit:
Types of interconnect modules available: (up to 4 per enclosure)
Ethernet Interconnect Switches from Cisco & Blade Network Technologies (BNT)
Ethernet Pass-Thru modules
Virtual Connect Ethernet modules (requires VC Management firmware v1.20 or greater)
Fibre Channel Interconnect Switches from Brocade & Cisco
Virtual Connect Fibre Channel modules
Fibre Channel Pass-Thru module.
InfiniBand Switch modules
For additional HP BladeSystem c-Class Interconnect Component information, please visit:
HP Insight Control Environment for BladeSystem management software: (Choice of either a trial use DVD, or an 8 blade fully
licensed DVD)
A fully licensed DVD covers all 8 blades in the HP BladeSystem Enclosure with no need to buy separate management
and/or provisioning tools
Insight Control Environment for HP BladeSystem contains the following components:
HP Systems Insight Manager (HP SIM) with the HP BladeSystem Integrated Manager (BSIM).
HP iLO 2 Select Pack licenses
HP ProLiant Essentials Rapid Deployment Pack (RDP)
HP ProLiant Essentials Insight Power Management Pack (IPM)
HP ProLiant Essentials Virtual Machine Management Pack (VMM)
HP ProLiant Essentials Performance Management Pack (PMP)
HP ProLiant Essentials Vulnerability and Patch Management Pack (VPM)
Warranty:
This product is covered by a global limited warranty and supported by HP Services and a worldwide network of HP
Authorized Channel Partners. Hardware diagnostic support and repair is available for three years from date of
purchase. Support for software and initial setup is available for 90 days from date of purchase. Enhancements to
warranty services are available through HP Care Pack services or customized service agreements. SATA hard drives
have a one year warranty.
NOTE: Server Blade Enclosure Limited Warranty includes 3 year Parts, 3 year Labor, 3-year on-site support.
For additional information please visit:
DA - 12790
Worldwide — Version 12 — July 14, 2008
Page 3
QuickSpecs
Models
HP BladeSystem c3000 Enclosure
HP BladeSystem
c-Class Server Blade
Enclosures
Rack Models - Supports a full enclosure of 8 blades
HP BladeSystem c3000 Single-Phase Enclosure
NOTE: Includes 4 AC Power Supplies, 6 Fans, an Onboard Administrator module, a
DVD drive, rail kit, and 8 Insight Control Environment Licenses.
437504-B22
HP BladeSystem Single-Phase c3000 Enclosure
437502-B22
437504-B21
437502-B21
NOTE: Includes 4 AC Power Supplies, 6 Fans, an Onboard Administrator module, a
DVD drive, rail kit, and 8 Insight Control Environment Trial Licenses.
Rack Models - A "starter" enclosure that supports up to 4 blades
HP BladeSystem c3000 Single-Phase Enclosure
NOTE: Includes 2 AC Power Supplies, 4 Fans, an Onboard Administrator module, a
DVD drive, rail kit, and 8 Insight Control Environment Licenses; additional power
supplies and fans can subsequently be added to support more than 4 blades.
HP BladeSystem Single-Phase c3000 Enclosure
NOTE: Includes 2 AC Power Supplies, 4 Fans, an Onboard Administrator module, a
DVD drive, rail kit, and 8 Insight Control Environment Trial Licenses; additional power
supplies and fans can subsequently be added to support more than 4 blades.
Tower Models - Supports a full enclosure of 8 blades
HP BladeSystem c3000 Tower Enclosure with 8 Insight Control Environment for
BladeSystem Licenses
NOTE: Includes 4 AC Power Supplies, 6 Fans, an Onboard Administrator module, a
DVD drive and 8 Insight Control Environment Licenses.
HP BladeSystem c3000 Tower Enclosure with 8 Insight Control Environment Trial
Licenses.
458033-B21
458032-B21
NOTE: Includes 4 AC Power Supplies, 6 Fans, an Onboard Administrator module, a
DVD drive and 8 Insight Control Environment Trial Licenses.
Tower Models - A "starter" enclosure that supports up to 4 blades
HP BladeSystem c3000 Tower Enclosure
NOTE: Includes 2 AC Power Supplies, 4 Fans, an Onboard Administrator module, a
DVD drive and Trial Licenses; additional power supplies and fans can subsequently be
added to support more than 4 blades.
469499-B21
469500-B21
HP BladeSystem c3000 Tower Enclosure
NOTE: Includes 2 AC Power Supplies, 4 Fans, an Onboard Administrator module, a
DVD drive and Insight Control Environment for BladeSystem Licenses; additional
power supplies and fans can subsequently be added to support more than 4 blades.
DA - 12790
Worldwide — Version 12 — July 14, 2008
Page 4
QuickSpecs
HP BladeSystem c-Class Overview
HP BladeSystem c3000 Enclosure
NOTE: For a brief, printer friendly data sheet that describes this product and informs you of the essential capabilities and
HP BladeSystem Overview As server, storage and network technologies have changed; traditional rack-mounted infrastructure
solutions have generated increased complexity of both infrastructure management and physical
datacenter deployment.
HP BladeSystem is the evolution of rack-mounted and pedestal infrastructure. A BladeSystem reduces
costs and simplifies the management, building, and maintenance of the infrastructure behind your multi-
server environment. It consolidates and repackages all the supporting infrastructure elements-compute,
storage, network, and power into a single platform that can accelerate the integration and optimization
of your data center.
The HP BladeSystem c3000 enclosure has the flexibility to scale from a single enclosure holding up to 8
blades, to a rack containing 7 enclosures holding up to 56 blades, the c-Class infrastructure is designed
to meet the needs of today's businesses. The c3000 enclosure is designed for several markets:
Remote sites or branch offices holding between 3 and 8 servers, and in deployment sites such as
retail stores, branch offices, manufacturing sites, and wiring closets. This enclosure is also
designed for harsh environments not found in modern datacenters (high ambient temperatures,
dusty environments, and in ships, airplanes, platforms, and vehicles).
Small and medium businesses, who own between 3 and 100 servers. The enclosure is designed
for use with management devices such as local KVM switches for local administration.
Datacenters with special power and cooling constraints, such as datacenters needing DC powered
racks, and/or datacenters with low power & cooling capacities (under 3000 watts per rack).
HPC clusters with InfiniBand interconnection, where the applications need a 1 to 1 IB network
subscription ratio between physical nodes in the compute cluster.
HP BladeSystem c-Class infrastructure is made up of several components:
HP ProLiant and/or HP Integrity Server blades for HP-UX, Windows, Linux, and HP Open VMS.
Choice of Intel® or AMD processors, including the latest dual-core & quad-core processors for
32-bit and 64-bit applications.
HP BladeSystem c-Class enclosure (either a c7000 or c3000) that provides connectivity, power,
and cooling options. The c-Class enclosure is designed for full redundancy and high availability. A
configurable choice of either redundant or non-redundant power, cooling, enclosure
management, and interconnect modules are part of the standard enclosure design.
Onboard Administrator module which provides a single point of control for intelligent
management of the entire enclosure.
Insight Display powered by the Onboard Administrator provides local management through an
LCD display conveniently sited on the front of the system.
Virtual Connect, Ethernet, Fibre Channel, InfiniBand, iSCSI, and other interconnect choices
A power subsystem that provides either redundant or non-redundant power modes and Dynamic
Power Saving mode, which uses up to 30% less power than traditional rack-mounted and tower
servers.
PARSEC (Parallel, Redundant, Scaleable, Enclosure Cooling) architecture: for maximum cooling
that consumes less power and reduces datacenter noise.
Direct-attach storage blades, and shared storage blades, which will provide file-based or block-
based shared storage capacity for the servers within the enclosure.
DA - 12790
Worldwide — Version 12 — July 14, 2008
Page 5
QuickSpecs
HP BladeSystem c-Class Overview
HP BladeSystem c3000 Enclosure
HP ProLiant & Integrity
Server Blades
Delivering best-in-class performance, choice and reliability with AMD Opteron™, Intel® Xeon™, and
Intel® Itanium processors for HP-UX, Windows, Linux, or HP-pen VMS based servers, the HP portfolio of
server blades supports a variety of application requirements for scale-out architectures. HP offers one-,
two-, and four-processor (dual-core & quad-core) server blades, including the widest range of
performance, and form factors, and the most processing density and performance of any other portfolio.
This portfolio of servers is designed for 32-bit and 64-bit applications.
For more information please see:
HP SB40c Storage Blade The StorageWorks SB40c is a half-height c-Class storage blade featuring support for up to six hot-plug
Small Form Factor (SFF) Serial Attached SCSI (SAS) or Serial ATA (SATA) hard disk drives. The SB40c
connects directly to the adjacent server blade to provide up to 876GB additional storage capacity to that
blade. For maximum fault tolerance the SB40c uses supports hardware RAID 0, 1, 1+0, 5, and 6
(ADG), using the onboard Smart Array P400 with up to 256MB of battery-backed write cache.
For more information please see:
HP StorageWorks Tape
Blades
The HP StorageWorks SB920c Tape Blade is an LTO-3 Ultrium tape blade that provides up to 800GB of
capacity on a single data cartridge (2:1 compression) and performance up to 432GB/hr (2:1
compression).
The Ultrium 448c Tape Blade is an LTO-2 Ultrium tape blade the provides up to 400GB of capacity on
a single data cartridge (2:1 compression) and performance up to 173GB/hr (2:1 compression).
Both tape blades are ideal for HP BladeSystem c-Class customers who need an intgrated data protection
solution for their enclosure. They provide direct attach data protection for the adjacent server and
network backup protection for all other data within the enclosure. The HP StorageWorks tape blades are
the industry's first bladed tape drives and are developed exclusively for the BladeSystem c-Class
enclosures.
For more information, please visit:
HP StorageWorks AiO
SB600c Storage Blade
The HP AiO SB600c Storage Blade Solution helps customers create HP c-Class BladeSystem business
solutions by consolidating file serving (NAS), shared application storage (iSCSI SAN), and data protection
under a unified management umbrella to deliver outstanding value and utility. The AIO SB600c Storage
Blade Solution consists of the following components; a half-height c-Class server blade, a storage blade
with 1.16 TB of raw storage capacity, and HP Management software.
For more information, please visit:
DA - 12790
Worldwide — Version 12 — July 14, 2008
Page 6
QuickSpecs
HP BladeSystem c-Class Overview
HP BladeSystem c3000 Enclosure
HP BladeSystem c-Class A BladeSystem c3000 enclosure holds up to 8 server and/or storage blades plus redundant or non-
c3000 Enclosure
redundant network and storage switches. It includes a shared, multi-terabit high-speed mid-plane for
wire-once connectivity of server blades to network and shared storage. Power is delivered through a
pooled power backplane that ensures the full capacity of the power supplies is available to all blades.
Each c3000 enclosure is built with the following functions:
Up to 8 half-height and/or up to 4 full-height server blades and/or storage blades per enclosure.
Up to 3 different interconnect fabrics (Ethernet, FC, IB, iSCSI, SAS, etc.) supported simultaneously
within the enclosure.
A single-phase power subsystem - for flexibility in connecting to datacenter power, or to UPS's or to
low-line wall outlets.
PARSEC enclosure design - Parallel, redundant and scalable cooling and
airflow design
Four (4) to Six (6) Active Cool fans
Fully redundant design - no single point of failure; redundant interconnections between servers
and interconnect modules; a mid-plane with no active components; redundant cooling using
Active Cool fans; all devices are hot-pluggable and customer replaceable.
Best performance per watt - lower wattage per server blade, in comparison to rack-mounted
servers
Full AC redundancy - with no power zones.
Single or redundant Onboard Administrator management modules (optional active-standby
design)
An Onboard Administrator management module is built in to the enclosure with the following functions:
Robust, multiple enclosure setup and control.
Reports asset and inventory information for the devices in the enclosure.
Reports thermal and power information, including real-time actual power usage per server and per
enclosure.
Front-mounted Insight Display for easy management at the deployment site.
Integrated access to all server blade iLOs from a single cable.
Provides integrated access to interconnect bay device management ports from the single Onboard
Administrator cable.
Single sign-on capability for all devices in the enclosure
Role-based security locally and/or with LDAP directory services.
Provides a wizard-based initial setup process for easy configuration.
An optional DVD drive for local software deployment, and HP SmartStart deployment
An optional local KVM interface for connection to KVM switches.
A BladeSystem c3000 enclosure provides the following benefits:
With local and remote hardware management integrated across the solution, one full enclosure
can be managed as easily as one server.
Scalable: Management and network interconnects extend scalability beyond a single enclosure,
allowing resources to be pooled and shared across multiple enclosures.
Investment protection: Accommodates multiple server and network designs in one enclosure.
Lower costs per server, in comparison to rack-mounted servers
Lower power consumption, in comparison to rack-mounted servers.
Service and management: Allows multiple administrators to remotely access and maintain multiple
servers & interconnect devices simultaneously.
DA - 12790
Worldwide — Version 12 — July 14, 2008
Page 7
QuickSpecs
HP BladeSystem c-Class Overview
HP BladeSystem c3000 Enclosure
HP BladeSystem c-Class HP also offers one of the broadest selections of interconnect fabric options in the industry to provide
Interconnect Options
network, SAN/network attached storage (NAS), and cluster connectivity.
HP BladeSystem interconnects provide:
New HP Virtual Connect devices, designed to reduce networking costs and simplify network
configuration and provisioning.
Seamless integration of Ethernet, FC, InfiniBand, iSCSI, and SAS fabrics: Standard-based switch
options include Cisco, Brocade, and HP (BNT) products that integrate within your existing
standards.
Built-in redundancy: Rear-mounting interconnect modules designed for redundant interconnections
between server blades and switches.
Cable reduction: Interconnect switches provide up to 32-to-1 network cable reductions per server
blade enclosure
For more information HP BladeSystem c-Class Interconnect Components, please visit:
Factory Express Portfolio HP Factory Express offers configuration, customization, integration and deployment services for HP
for Servers and Storage servers and storage products. Customers can choose how their factory solutions are built, tested,
integrated, shipped and deployed.
Factory Express offers service packages for simple configuration, racking, installation, complex
configuration and design services as well as individual factory services, such as image loading, asset
tagging and custom packaging. HP products supported through Factory Express include: a wide array of
servers and storage: HP Integrity, HP ProLiant & HP ProLiant & Integrity Server Blades, HP BladeSystem,
HP 9000 servers as well as the MSAxxxx, VA7xxx, EVA, XP, rackable tape libraries and configurable
network switches.
For more information on Factory Express services for your specific server model please contact your sales
HP Insight Control
Environment for
Insight Control Environment for BladeSystem delivers foundation management for HP BladeSystem
lifecycles, including remote monitoring, hardware resource deployment, health monitoring, software
BladeSystem Management version control, performance monitoring, vulnerability scanning and patch management and power
Suite
management.
Insight Control Environment for BladeSystem installs and licenses the following components by default
using a wizard-based integrated installer:
HP Systems Insight Manager(SIM)
HP iLO Select Pack
HP ProLiant Essentials Rapid Deployment Pack(RDP)
HP Insight Power Manager(IPM)
HP ProLiant Essentials Virtual Machine Manager (VMM)
HP ProLiant Essentials Performance Management Pack (PMP)
HP ProLiant Essentials Vulnerability and Patch Management Pack
Additional ProLiant Essentials software and management tools included in the Insight Control
Management media kit can be installed manually.
HP Server Migration Pack – Universal Edition
DA - 12790
Worldwide — Version 12 — July 14, 2008
Page 8
QuickSpecs
HP BladeSystem c-Class Overview
HP BladeSystem c3000 Enclosure
NOTE: HP Server Migration Pack - Universal Edition is licensed separately from the Insight Control
Environment Suite.
HP Open Service Event Manager
HP Instant Support Enterprise Edition
NOTE: HP Server Migration Pack – Universal Edition can be installed from the SMP-P2P CD included in
the Insight Control Management media kit.
NOTE: HP Insight Control Environment for BladeSystem can be installed from the Insight Control
Management DVD, which can be delivered with HP BladeSystem c-Class enclosures with a choice of
licensing options. Licensing options include a free 30 day evaluation license for 8 servers (default option
for every enclosure order), a full purchased license for 8 blade servers or a full purchased license for 16
blade servers). For additional information on HP c-Class Infrastructure please visit: HP BladeSystem c-
Class Infrastructure QuickSpecs:
NOTE: For additional product and licensing information about HP Insight Control Environment for
BladeSystem, HP Systems Insight Manager and Essentials software refer to:
iLO Power Management Pack for BladeSystem is energy-efficient management software that delivers
centralized control, reliable security, and energy savings for your BladeSystem infrastructure. iPMP
combines the total control of iLO 2 Advanced in the area of remote management with the energy
monitoring and control of the Insight Power Manager to deliver a robust solution capable of full remote
control and power management of ProLiant servers through a unified interface within HP Systems Insight
Manager.
HP Insight Control Environment for Linux (ICE-Linux) provides comprehensive discovery, imaging &
deployment, monitoring, and management for Linux-based ProLiant server platforms. Built on the
industry-leading HP Systems Insight Manager framework, this solution integrates open source technology
with experience leveraged from HP's Linux products in HP ICLE and HP XC Clusters, while providing
paths to the future with developing management technologies.
HP Insight Control management suites and select HP ProLiant Essentials include one year of 24 x 7 HP
Software Technical Support and Update Service ensuring rapid access to HP support staff and proactive
delivery of software updates. For more information about this service, please visit:
Server Management Stand HP Systems Insight
Alone Software Product - Manager
ProLiant Essentials
HP Systems Insight Manager (HP SIM) provides a unified, secure and
extensible standards-based environment to centrally manage servers, storage
and other infrastructure devices, (both HP and non-HP) across multiple
operating system platforms.
ProLiant Essentials Rapid Rapid Deployment Pack (RDP) extends HP Systems Insight Manager with a
Deployment Pack
complete deployment solution for HP ProLiant blade servers. RDP provides a
central location to configure server hardware, deploy Windows, Linux and
VMware ESX operating environments and install HP ProLiant Support Pack
drivers using images and scripted profiles.
ProLiant Essentials Server Upgrading, replacing, or virtualizing your existing server? Effortlessly
Migration Pack – Universal transition to new virtual or physical HP ProLiant servers or BladeSystem with
Edition
automated, accurate and affordable migration of OS, application and data.
SMP Universal automates the manual processes required for migrating
servers between physical or virtual platforms, whether migrating to VMware
or Microsoft virtual machines. SMP Universal allows all of the following
DA - 12790
Worldwide — Version 12 — July 14, 2008
Page 9
QuickSpecs
HP BladeSystem c-Class Overview
HP BladeSystem c3000 Enclosure
migrations:
physical to ProLiant
physical to virtual
virtual to virtual
virtual to ProLiant
Performance Management Pack (offered exclusively through the Insight
ProLiant Essentials
Performance Management Control suites) – a performance management solution that identifies and
Pack
explains hardware performance bottlenecks on ProLiant servers and attached
options enabling users to better utilize their valuable resources.
Integrated Lights-Out
Select Pack
Upgrades the iLO 2 processor with enhanced console sharing and replay,
virtual media (floppy, CD/DVD, USB key), virtual folders, historical power
reporting, power capping and enterprise security (directory services and two-
factor authentication) for servers managed using remote consoles available in
iLO 2 Standard and iLO 2 Standard Blade Edition.
HP Insight Power Manager Upgrades the single-server remote management capabilities of iLO
(IPM)
Select/Advanced to include centralized reporting and policy-based
management of power consumption and thermal output provided by the
Insight Power Manager. IPM unifies all of this functionality within a single user
interface - HP Systems Insight Manager.
Virtual Connect Enterprise Simplifies the management of BladeSystem environments that use Virtual
Manage
Connect to control LAN and SAN connectivity, helping organizations increase
productivity, respond more quickly to business demands, and significantly
reduce operating costs.
ProLiant Essentials Virtual Virtual Machine Management Pack – provides central management and
Machine Management
Pack
control of virtual machines from Microsoft and VMware. Integrated approach
provides the ability to manage both physical and virtual resources from a
single management console.
ProLiant Essentials
Vulnerability and Patch
Management Pack
Vulnerability and Patch Management Pack (offered exclusively through the
Insight Control suites) – identifies and remediates software security
vulnerabilities due to missing patches as well operating system configurations
that can be exploited by viruses, worms, and other blended threats.
NOTE: Flexible and volume quantity license kits are available for ProLiant Essentials Value Packs. Refer
to: http://www.hp.com/servers/proliantessentials or the various ProLiant Essentials Value Pack product
QuickSpecs for more information.
DA - 12790
Worldwide — Version 12 — July 14, 2008
Page 10
QuickSpecs
HP BladeSystem c-Class Overview
HP BladeSystem c3000 Enclosure
Core Infrastructure
Management
SmartStart
SmartStart is a tool that simplifies server setup, providing a rapid way to
deploy reliable and consistent server configurations. For more information,
please visit the SmartStart Web site at:
Insight Management
Agents
The Insight Management Agents should be installed on all HP servers to
present system instrumentation, health and configuration information into HP
Systems Insight Manager and the HP System Management Homepage. The
HP System Management Homepage aggregates systems data from Insight
Management Agents and other HP management tools, providing a
consolidated browser-based interface for managing individual servers.
Insight Management Agents and The HP System Management Homepage
are included on ProLiant Support Packs, and can also be installed using the
server profiles provided with the ProLiant Essentials Rapid Deployment Pack.
For additional information about the Management Agents and the HP System
Management Homepage please visit the management Web site at:
Subscriber's Choice
Subscriber's Choice Driver and Support Alerts/Notifications is a web-based
email subscription service that provides software and driver change
notifications for ProLiant products. Sign up at:
and customize your profile to receive various new alerts as they become
available, on a weekly or monthly basis.
ProLiant Support Packs
and ROMPaq, software
The latest software, drivers, and firmware fully optimized and tested for your
ProLiant server and options, available through ProLiant Support Packs the
ProLiant Essentials Rapid Deployment Pack, SmartStart or downloaded from
Software and Drivers download pages website at:
HP Enterprise
Configurator
The HP eCo-Enterprise Configurator now provides factory default racking for our HP hardware portfolio.
This approach is aligned with our strategic direction to meet the needs and expectations of our valued
customers. If you require "custom" rack configuration, please contact HP's Customer Business Center or
an Authorized Partner for assistance.
DA - 12790
Worldwide — Version 12 — July 14, 2008
Page 11
QuickSpecs
HP BladeSystem c-Class Overview
HP BladeSystem c3000 Enclosure
HP BladeSystem Power
Sizer
The HP BladeSystem Power Sizer helps in sizing the power infrastructure needed for a HP BladeSystem
solution. This sizer enables effective planning for the power consumption and heat load of the
BladeSystem at its site.
The sizer enables you to:
Select the type and number of components within each Blade Server and Blade Enclosure.
View the effect of component changes on the power consumption and heat loading.
Review server loading and determine power supply and power subsystem requirements.
Approximate electrical and heat load for facilities planning purposes.
The sizing estimate is based on component level power measurements for a system stressed to maximum
capability.
Values obtained from the BladeSystem Sizer tool are measured with all components stressed to 100%
load and are intended for facilities planning purposes only. Actual power consumption varies with
application type, application utilization, and ambient temperature.
The p-class BladeSystem and the c-Class BladeSystem solutions are supported in the BladeSystem Power
Sizer.
Available at: http://www.hp.com/go/bladesystem/powercalculator
Service and Support
HP Care Pack services provide total care and support expertise with committed response designed to
meet your IT and business needs.
The HP Care Pack service for HP ProLiant BL c-Class server blades, cover the server blade and all HP
branded hardware options qualified for the server, purchased at the same time or afterwards, internal to
the server.
HP Care Pack services for the c7000 and c3000 enclosures cover the enclosure, power supplies and
fans. HP qualified rack options are covered by these services when installed within the same rack. HP
supported c-Class enclosure devices including pass thru, Ethernet interconnect and virtual connect
modules are also covered by the c7000 and c3000 enclosure Care Pack services.
NOTE: SAN/Fabric switches for the HP c-Class BladeSystem are not covered under the c7000 and
c3000 enclosure Care Packs, SAN/Fabric switches carry separate Care Packs. SAN/Fabric Switch Care
Pack service level support should always be uplifted to match existing storage or server service level.
To fully capitalize on your HP BladeSystem servers' capabilities requires a service partner who thoroughly
understands your server technology and systems environment. HP Services, an industry leader in
provision of multi vender support solutions provides a range of support services designed to meet the
varying needs of business. Whether an SMB or large global corporation HP has a HP BadeSystem server
support offer to help you speedily deploy and maximize system uptime.
Recommended Service – Simplify ProLiant solution implementation, maintenance and management.
Support Service – 4-Hour Response Coverage, 3-Year, 24 x 7, Same Business Day
Deployment Service – Installation and Start Up for HP BladeSystem Infrastructure
Enhanced Service – Optimize service level to increase IT performance and availability
Support Service – HP Proactive BladeSystem Service, 1-Year
DA - 12790
Worldwide — Version 12 — July 14, 2008
Page 12
QuickSpecs
HP BladeSystem c-Class Overview
HP BladeSystem c3000 Enclosure
Deployment Service – Enhanced Network Installation and Start-up for HP BladeSystem Switches
Installation & Start-Up service for HP BladeSystem Infrastructure plus HP BladeSystem Enhanced Network
Installation and Start-UP as per the Customer Description and/or Data Sheet. To be delivered on a
scheduled basis 8am-5pm, M-F, excluding HP holidays.
For a complete listing of service offerings and information visit:
DA - 12790
Worldwide — Version 12 — July 14, 2008
Page 13
QuickSpecs
Configuration Information Factory Integrated Models
HP BladeSystem c3000 Enclosure
NOTE: This section lists some of the steps required to configure a Factory Integrated Model. To ensure only valid configurations are
ordered, HP recommends the use of an HP approved configurator. Contact your local sales representative for information on CTO
product offerings and requirements.
NOTE: HP does not allow factory integration of options into standard models listed above.
Configure-to-order server blades must start with a CTO Blade.
NOTE: This product offering does not support HP Factory Express Server Configuration Level 1.
NOTE: FIO indicates that this option is a Factory Installable Option.
For a complete configuration of the HP BladeSystem, please do the following:
Step 1: Select desired model, configuration and quantity of HP ProLiant server and Storage
blades
NOTE: For server blade information, please visit:
NOTE: For Storage Blade information, please visit:
Step 2: Determine quantity of HP BladeSystem c-3000 Enclosures to purchase and choose
Required Options
(One of the following from each list unless otherwise noted):
NOTE: Each HP BladeSystem c3000 Server Blade Enclosure holds up to 8 half-height blades, or up to 4 full-height server blades.
Server blanks will be shipped in all empty bays.
Select Base Server Blade Enclosure Configuration
HP BladeSystem BLc3000
c-Class Server Blade
Enclosures
Choose one of the following CTO enclosures
HP BLc3000 CTO Enclosure
437507-B21
458034-B21
NOTE: CTO model includes 4 Active Cool Fans
HP BLc3000 CTO Enclosure – Tower
NOTE: CTO model includes 4 Active Cool Fans
Select Required Options (Choose one of the following from each category unless otherwise
noted)
Onboard Administrator
HP BLc3000 Onboard Administrator, FIO
NOTE: Supports CTO Enclosure – Rack (p/n 437507-B21) only.
HP BL3000 Tower Onboard Administrator, FIO
NOTE: Supports CTO Enclosure – Tower (p/n 458034-B21) only.
HP 1200W High Efficiency AC Power Supply, CSCI 2007/8
NOTE: Meets Climate Savers Computing Initiative, 2007-2008.
NOTE: Minimum 1 Power Supply required. For additional Power Supplies, please see
step 2A of this QuickSpecs.
448589-B21
461514-B21
437572-B21
Power Supplies
NOTE: AC power supplies include a C13 to C14 PDU power cord. NOTE: Order
additional power supplies, as determined by the use of the HP BladeSystem Power
Calculator.
NOTE: For a full enclosure, order 4 power supplies in a Power Supply Redundant
(N+1) configuration; order 6 power supplies in an AC Redundant (N+N)
configuration
DA - 12790
Worldwide — Version 12 — July 14, 2008
Page 14
QuickSpecs
Configuration Information Factory Integrated Models
HP BladeSystem c3000 Enclosure
Step 2A: Select additional optional enclosure options:
Additional C3000 Power HP 1200W High Efficiency AC Common Slot Power Supply
437572-B21
Supplies
NOTE: Meets Climate Savers Computing Initiative, 2007-2008
NOTE: AC power supplies include a C13 to C14 PDU power cord.
NOTE: Order additional power supplies, as determined by the use of the HP
BladeSystem Power Calculator.
NOTE: For a full enclosure, order 4 power supplies in a Power Supply Redundant
(N+1) configuration; order 6 power supplies in an AC Redundant (N+N)
configuration.
c-Class Active Cool Fan HP BL c-Class Active Cool Fan
NOTE: For a full enclosure, order 2 additional (6 total) Active Cool Fans.
HP c3000 Enclosure DVD HP c3000 Enclosure DVD Drive
Drive
412140-B21
437577-B21
437575-B21
AF603A
HP c3000 KVM Modules HP c3000 KVM module
and Adapters
NOTE: For use with in-rack KVM switches.
KVM Adapter for KVM switches with internal media drives
NOTE: Order one KVM Adapter per c3000 enclosure, to support KVM switches
accepting RJ45 cables (P/N's AF600A, AF601A, or AF602A). Please see Options
section of this QuickSpecs for additional product information.
Other Enclosure Options HP BLc3000 Rack Rails
NOTE: For use with the c3000 rack-able (437507-B21) model.
437576-B21
439034-B23
AF590A
HP Insight Control for
BladeSystem Licenses
Optional Power Cords
HP c-Class Insight Control Environment for BladeSystem, 8 server blade licenses
including 1 year of 24x7 Technical Support and Updates
Power Cord, C20 C13, 15A, Universal Jumper, 2m
NOTE: For use with PDU's accepting C20 power cords.
Step 3: Select additional (one to four) interconnects.
NOTE: Interconnect Bay 1 must contain one of the "Ethernet" interconnect modules For additional information on Interconnect
Options, please visit:
HP BladeSystem c-Class Interconnect QuickSpecs: http://h18000.www1.hp.com/products/quickspecs/12524_div/12524_div.html
HP BladeSystem
c-Class Ethernet
Interconnects
HP 1/10Gb-F Virtual Connect Ethernet Module for c-Class BladeSystem
HP BladeSystem c-Class Virtual Connect 1Gb SX SFP
HP BladeSystem c-Class Virtual Connect 1Gb RJ-45 SFP Opt Kit
HP 1Gb Virtual Connect Ethernet Module for c-Class BladeSystem
NOTE: This module must be upgraded to VC Management firmware v1.20 or greater.
Ethernet Pass-Through Module for HP BladeSystem
Cisco Catalyst Blade Switch 3120X for HP
Cisco Catalyst Blade Switch 3120G for HP
Cisco Catalyst Blade Switch 3020 for HP c-Class BladeSystem
GbE2c Ethernet Blade Switch for HP c-Class BladeSystem
GbE2c Layer 2/3 Ethernet Blade Switch for HP c-Class BladeSystem
HP 1:10 Gb Ethernet BL-c Switch
447047-B21
453151-B21
453154-B21
399593-B22
406740-B21
451439-B21
451438-B21
410916-B21
410917-B21
438030-B21
438031-B21
445860-B21
HP 10Gb Ethernet BL-c Switch
NOTE: The purchase the HP 10Gb Ethernet BL-c Switch, also requires the purchase of
one (1) HP NC512m Dual Port 10GbE Multifunction BL-c Adapter (P/N 440910-B21)
per server blade that requires 10Gbit support.
NOTE: The HP BladeSystem c-Class Network Interconnects ship as single units. The
above interconnects must be ordered in quantities of two for redundant configurations.
DA - 12790
Worldwide — Version 12 — July 14, 2008
Page 15
QuickSpecs
Configuration Information Factory Integrated Models
HP BladeSystem c3000 Enclosure
HP NC512m Dual Port 10GbE Multifunction BL-c Adapter
440910-B21
NOTE: An NC512m network adapter card is required for each server blade
connecting to the HP 10Gb Ethernet BL-c Switch
NOTE: Two NC512m adapters are supported per ProLiant c-Class full height server in
type II x8 PCI Express mezzanine slots and one adapter per a type II x8 PCI Express
mezzanine slot in a half height server. For more information, see the Mezzanine Slot
Compatibility matrix within the HP NC512m Dual Port 10GbE Multifunction BL-c
Adapter QuickSpecs:
NOTE: The NC512m requires a minimum of 2 GB of server memory per NC512m
card and supports a maximum of 32 GB for Windows and 64 GB for Linux. NOTE:
Each port on the NC512m transmits from the server only at 20 Gbps full duplex per
port.
HP BladeSystem
c-Class FC SAN
Interconnects
HP 4Gb Virtual Connect Fibre Channel Module for c-Class BladeSystem
16 port FC Pass-thru Module for c-Class BladeSystem
HP 8/12c SAN Switch c-Class BladeSystem
HP 8/24c SAN Switch c-Class BladeSystem
HP 8/24c SAN Switch Power Pack c-Class Enclosure
HP 8/12c Switch 12-pt c-Class Upgrade LTU
HP Brocade 4/12 SAN Switch
409513-B21
403626-B21
AJ820A
AJ821A
AJ822A
T5517A
AE370A
HP Brocade 4/24 SAN Switch Power Pack
HP Brocade 4/24 SAN Switch
AE371A
AE372A
HP Brocade 4/12 SAN Switch Upgrade LTU
Cisco MDS 9124e 12 port Fabric Switch
HP 4X DDR IB Switch Module for HP c-Class BladeSystem
AE373A
AG641A
410398-B21
HP BladeSystem
InfiniBand Interconnects
Step 4: Select rack power distribution for installing the enclosure into a rack.
NOTE: For use with the c3000 rack-able model only.
NOTE: A pair of PDUs must be ordered for AC Feed redundancy. If AC redundancy is not required, a single PDU or UPS may be
acceptable.
HP Monitored Power
Distribution Unit
HP 8.6 kVA Monitored PDU, 30A (NA/JPN)
HP 11 kVA Monitored PDU 16A (INTL)
AF504A
AF508A
HP Modular Power
Distribution Unit
HP 8.3kVA Modular Distribution Unit 40 Amp (NA/JPN)
HP 8.3kVA Modular Distribution Unit 40 Amp (Intl)
HP 7.3kVA Modular Distribution Unit 32 Amp (Intl)
HP 4.9kVA Modular Distribution Unit 24 Amp (NA/JPN)
HP Two C-13 PDU Extension Bars
252663-D73
252663-B32
252663-B31
252663-D72
AF500A
Uninterruptible Power
HP rack-mountable R5500 UPS (5000VA / 4500 watts)
AF426A
Systems - Rack Mountable NOTE: The R5500 includes four c-13 PDU Extension bars.
NOTE: The R5500 supports 4 power supplies in the Power Supply Redundant (N+1)
power mode
HP Rack to Tower 5500 Conversion Kit
AF442A
DA - 12790
Worldwide — Version 12 — July 14, 2008
Page 16
QuickSpecs
Configuration Information Factory Integrated Models
HP BladeSystem c3000 Enclosure
(For connection to standard wall outlets)
Step 5: Select Wall Outlet Power Cords
NOTE: Select one wall outlet power cord for each power supply when plugging the power supplies into a wall outlet.
NOTE: Wall Outlet power cords should only be used with low-line (100v to 110V) power sources. If high-line power outlets are
required, safety regulations require the use of a PDU or a UPS between the c3000 enclosures power supplies and wall outlets.
NOTE: A standard PDU power cord(c13 to C14) is included with each AC power supply, so these wall outlet power cords are not
required if you plan to plug the power supplies into a PDU or UPS.
Order the appropriate power cord for your countries standard electrical outlets.
Wall Outlet Power Cords Nema 5-15P to IEC320-C13, low voltage (6 ft/2 m), North America
NOTE: HP Power cord (6 ft) 1.83 meter 10A C-13-UL domestic power cord, for
grounded USA 110V wall outlets.
AF556A
Power Cord, C13,10A , 1.83m, Japan
NOTE: HP Power cord 2 meter C13 Japan low-line power cord, for Japanese 100V
wall outlets.
Power Cord, C20 C13, 15A, Universal Jumper, 2m
NOTE: For use with PDUs accepting C20 power cords.
AF572A
AF590A
DA - 12790
Worldwide — Version 12 — July 14, 2008
Page 17
QuickSpecs
Related Options
HP BladeSystem c3000 Enclosure
c3000 Enclosure Options HP c-Class Replacement Enclosure Miscellaneous Blanks kit
412148-B21
NOTE: Contains 1 each of Power Supply Blank, Interconnect Module Blank, Local
KVM option blank, DVD Blank, Active Cool Fan Blank, and c3000 minidivider)
NOTE: This kit should only be ordered to replace lost or damaged blanks.
HP c-Class Replacement Server Blank and Coupler Option Kit (contains 1 x half-
height server blank with coupler)
412150-B21
NOTE: The coupler allows half-height server blanks to be coupled together to create a
full-height server blank.
NOTE: This kit should only be ordered to replace lost or damaged blanks.
c3000 Rack Brackets
c-Class Power Supply
HP c3000 Rack Shipping Bracket Kit
NOTE: Required when shipping a c3000 enclosure in a HP 10000 series rack. Please
order 1 kit per enclosure.
461384-B21
437572-B21
HP 1200W High Efficiency AC Common Slot Power Supply
NOTE: Meets Climate Savers Computing Initiative, 2007-2008.
NOTE: AC power supplies include a C13 to C14 PDU power cord.
NOTE: For c-3000 Low-line Power Cords, please order the appropriate power cord
for your countries standard electrical outlets. Please see Step 5 above for power cord
part numbers.
c-Class Active Cool Fans HP c-Class Active Cool Fan
NOTE: For a full enclosure, order 2 additional (6 total) Active Cool Fans.
412140-B21
437577-B21
NOTE: Supports the c7000 and c3000 enclosures.
HP BLc3000 Enclosure
DVD Drive
HP c3000 Enclosure DVD Drive
HP c3000 KVM Module HP c3000 KVM Module
and Adapters NOTE: For use with in-rack KVM switches
437575-B21
AF603A
KVM Adapter for KVM switches with internal media drives
NOTE: Order one KVM Adapter per c3000 enclosure, to support KVM switches
accepting RJ45 cables (P/N's AF600A, AF601A, or AF602A). Please see Options
section of this QuickSpecs for additional product information.
Other c3000 enclosure HP BLc3000 Rack Rails
options NOTE: For use with the c3000 rack models.
437576-B21
DA - 12790
Worldwide — Version 12 — July 14, 2008
Page 18
QuickSpecs
Related Options
HP BladeSystem c3000 Enclosure
HP BladeSystem
c-Class Ethernet
Interconnects
HP 1/10Gb-F Virtual Connect Ethernet Module for c-Class BladeSystem
HP BladeSystem c-Class Virtual Connect 1Gb SX SFP
HP BladeSystem c-Class Virtual Connect 1Gb RJ-45 SFP Option Kit
HP 1Gb Virtual Connect Ethernet Module for c-Class BladeSystem
NOTE: This module must be upgraded to VC Management firmware v1.20 or greater.
Ethernet Pass-Through Module for HP BladeSystem
447047-B21
453151-B21
453154-B21
399593-B22
406740-B21
NOTE: The Ethernet Pass-Thru Module is shipped as a single unit and should be
ordered in quantities of two.
Cisco Catalyst Blade Switch 3120X for HP
Cisco Catalyst Blade Switch 3120G for HP
Cisco Catalyst Blade Switch 3020 for HP c-Class BladeSystem
GbE2c Ethernet Blade Switch for HP c-Class BladeSystem
HP GbE2c Layer 2/3 Ethernet Blade Switch
HP 1:10Gb Ethernet BL-c switch
451439-B21
451438-B21
410916-B21
410917-B21
438030-B21
438031-B21
HP BladeSystem
c-Class FC SAN
Interconnects
HP 4Gb Virtual Connect Fibre Channel Module for c-Class BladeSystem
16 port FC Pass-through Module for c-Class BladeSystem
HP 8/12c SAN Switch c-Class BladeSystem
HP 8/24c SAN Switch c-Class BladeSystem
HP 8/24c SAN Switch Power Pack c-Class Enclosure
HP 8/12c Switch 12-pt c-Class Upgrade LTU
HP Brocade 4/12 SAN Switch
409513-B21
403626-B21
AJ820A
AJ821A
AJ822A
T5517A
AE370A
HP Brocade 4/24 SAN Switch Power Pack
HP Brocade 4/24 SAN Switch
AE371A
AE372A
HP Brocade 4/12 SAN Switch Upgrade LTU
AE373A
Cisco MDS 9124e Fabric Cisco MDS 9124e 12-port Fabric Switch
AG641A
AG642A
T5169A
Switch for HP c-Class
BladeSystem
Cisco MDS 9124e 24-port Fabric Switch
Cisco MDS 9124e 12-port Upgrade LTU
HP BladeSystem
HP 4X DDR IB Switch Module for HP c-Class BladeSystem
410398-B21
InfiniBand Interconnects
DA - 12790
Worldwide — Version 12 — July 14, 2008
Page 19
QuickSpecs
Related Options
HP BladeSystem c3000 Enclosure
HP Insight Control
Environment for
NOTE: Electronic licensing options are available for Insight Control suites software
products. Please see the appropriate Insight Control QuickSpecs for additional
BladeSystem Management information.
Suite
HP Insight Control Environment for BladeSystem
HP Insight Control Environment for BladeSystem, No Media 1-Server License including
1 year of 24x7 Technical Support and Updates
NOTE: Customer will receive a printed license entitlement certificate via physical
shipment. The license entitlement certificate must be redeemed online or via fax in
order to obtain the license activation key(s). Includes one year of 24 x 7 HP Software
Technical Support and Update Service.
453484-B21
436222-B21
HP Insight Control Management Software Media Kit
NOTE: Insight Control Management DVD media without licenses. Contains Insight
Manager and Essentials software products and components licensed by Insight Control
Management suites. Uses an integrated installer to perform quick and accurate
software installation and updates.
NOTE: Contains 1 license for each of RDP, PMP, VPM, IPM and iLO Select. Includes
one year of 24 x 7 HP Software Technical Support and Update Service.
NOTE: For additional License Kits, please see the QuickSpecs at:
HP Insight Control Environment for Linux
HP Insight Control Environment for Linux, No Media, 8-Server license, including One
year of 24x7 Technical Support and Updates, FIO
464429-B21
NOTE: This part number can be used to purchase eight (8) server blade licenses with
a single activation key. Customer will receive a printed license entitlement certificate
via physical shipment. The license entitlement certificate must be redeemed online or
via fax in order to obtain the license activation key(s). Includes one year of 24 x 7 HP
Software Technical Support and Update Service. For Factory Integration only.
Orderable only with c-Class blade enclosure (c3000 or c7000).
NOTE: For additional information regarding the HP Virtual Connect Enterprise
Manager License kits, please visit:
iLO Power Management Pack for BladeSystem
HP iLO Power Management Pack for BladeSystem, No Media, 1-Server License
including 1 year of 24x7 Technical Support and Updates
442937-B21
NOTE: This option kit includes 1 license for iLO Select and Insight Power Manager.
Customer will receive a printed license entitlement certificate via physical shipment.
The license entitlement certificate must be redeemed online or via fax in order to
obtain the license activation key(s). Includes one year of 24 x 7 HP Software Technical
Support and Update Service.
NOTE: For additional HP Insight Power Manager Packs please see the QuickSpecs at:
Server Management Stand NOTE: Electronic licensing options are available for select ProLiant Essentials software
Alone Software Product – products. Please see the appropriate ProLiant Essentials QuickSpecs for additional
ProLiant Essentials
information.
Deploy
ProLiant Essentials Rapid Deployment Pack
ProLiant Essentials Rapid Deployment Pack No Media 1-Server License including 1
year of 24x7 Technical Support and Updates
NOTE: This license allows 1 server to be deployed and managed via RDP. Customer
452151-B21
Page 20
DA - 12790
Worldwide — Version 12 — July 14, 2008
QuickSpecs
Related Options
HP BladeSystem c3000 Enclosure
will receive a printed license entitlement certificate via physical shipment. The license
entitlement certificate must be redeemed online or via fax in order to obtain the license
activation key(s). Includes one year of 24 x 7 HP Software Technical Support and
Update Service.
NOTE: For additional ProLiant Essentials Rapid Deployment Pack License Kits- please
see the QuickSpecs at:
HP Server Migration Pack – Universal Edition
HP Server Migration Pack – Universal Edition, No Media, Physical / Virtual to ProLiant
Single Migration License, including 1 year of 24x7 Technical Support
NOTE: This license allows 1 physical to ProLiant or virtual to ProLiant migration.
Customer will receive a printed license entitlement certificate and documentation via
physical shipment. The license entitlement certificate must be redeemed online or via
fax in order to obtain the license activation key(s). Includes one year of 24 x 7 HP
Software Technical Support Service.
HP Server Migration Pack – Universal Edition, No Media, Physical / Virtual to Virtual
Single Migration License, including 1 year of 24x7 Technical Support
NOTE: This license allows 1 physical to virtual or virtual to virtual migration.
Customer will receive a printed license entitlement certificate and documentation via
physical shipment. The license entitlement certificate must be redeemed online or via
fax in order to obtain the license activation key(s). Includes one year of 24 x 7 HP
Software Technical Support.
460750-B21
460753-B21
460756-B21
HP Server Migration Pack – Universal Edition, No Media, 1-Year Unlimited Migration
License, including 1 year of 24x7 Technical Support
NOTE: This license allows unlimited migrations (physical to ProLiant, physical to
virtual, virtual to virtual, and virtual to ProLiant) for one year. Customer will receive a
printed license entitlement certificate and documentation via physical shipment. The
license entitlement certificate must be redeemed online or via fax in order to obtain the
license activation key(s). Includes one year of 24 x 7 HP Software Technical Support
Service.
NOTE: For additional License Kits, please see the QuickSpecs at:
Monitor
HP Insight Dynamics - VSE without Insight Control Environment, 1-server license
including 1 year of 24x7 Technical Support and Updates
NOTE: This license supports HP ProLiant ML/DL and c-Class Blade servers. Customer
will receive a printed license entitlement certificate via physical shipment.
NOTE: HP Insight Dynamics - VSE Suite supports the HP ProLiant ML/DL 300, 500,
700 series servers and HP ProLiant Blade servers.
483531-B21
483534-B21
HP Insight Dynamics - VSE with Insight Control Environment, 1-server license including
1 year of 24x7 Technical Support and Updates
NOTE: This license supports HP ProLiant c-Class Blade servers. Customer will receive
a printed license entitlement certificate via physical shipment.
NOTE: For additional information regarding the HP Insight Dynamic - VSE, please
Control
Integrated Lights-Out Select Pack
ProLiant Essentials Integrated Lights-Out Select Pack, No Media, 1-Server License
NOTE: For additional License Kits, please see the QuickSpecs at:
452158-B21
Page 21
DA - 12790
Worldwide — Version 12 — July 14, 2008
QuickSpecs
Related Options
HP BladeSystem c3000 Enclosure
Featuring: Sophisticated remote control and security features for HP BladeSystem
servers and ProLiant ML/DL servers.
NOTE: For additional ProLiant Essentials Integrated Lights-Out Value Packs please see
the QuickSpecs at:
Optimize
HP Insight Power Manager (IPM)
HP Insight Power Manager, No Media, 1-Server License, including 1 year of 24x7
Technical Support and Updates
452677-B21
NOTE: Customers purchasing this upgrade must already have an iLO Advanced or
Select license on each managed server. Customer will receive a printed license
entitlement certificate via physical shipment. The license entitlement certificate must be
redeemed online or via fax in order to obtain the license activation key(s). Includes one
year of 24 x 7 HP Software Technical Support and Update Service.
NOTE: For additional HP Insight Power Manager Packs please see the QuickSpecs at:
ProLiant Essentials Virtual Machine Management Pack
ProLiant Essentials Virtual Machine Management Pack, No Media, 1-Server License,
including 1 year of 24x7 Technical Support and Updates
452153-B21
NOTE: Customer will receive a printed license entitlement certificate via physical
shipment. The license entitlement certificate must be redeemed online or via fax in
order to obtain the license activation key(s). Includes one year of 24 x 7 HP Software
Technical Support and Update Service.
NOTE: For additional ProLiant Virtual Machine Management Pack License Kits please
see the QuickSpecs at:
NOTE: Flexible and volume quantity license kits are available for ProLiant Essentials
ProLiant Essentials Value Pack product QuickSpecs for more information.
NOTE: For more information regarding ProLiant Essentials Software, please see the
HP Virtual Connect
Enterprise Manager
HP Virtual Connect Enterprise Manager for BL-c3000, No Media, 1-Enclosure License
including 1 year of 24x7 Technical Support and Updates.
459867-B21
NOTE: This license allows 1 BL-c3000 enclosure to be managed with VCEM.
Customer will receive a printed license entitlement certificate via physical shipment.
The license entitlement certificate must be redeemed online or via fax to obtain the
license activation key(s). Includes one year of 24 x 7 HP Software Technical Support
and Update Service.
NOTE: For additional information regarding the HP Virtual Connect Enterprise
Manager License kits, please visit:
DA - 12790
Worldwide — Version 12 — July 14, 2008
Page 22
QuickSpecs
Related Options
HP BladeSystem c3000 Enclosure
HP c-Class Storage
Blades
HP StorageWorks SB40c storage blade
NOTE: For additional information regarding the HP StorageWorks SB40c storage
411243-B21
blade, please visit:
HP PCI Express Mezzanine pass-thru card for HP BladeSystem
NOTE: The mezzanine card is needed to support the SB40c storage blade (P/N
411243-B21) with HP c-Class BladeSystem full-height server blades.
431643-B21
HP c-Class Tape Blades HP StorageWorks Ultrium 448c Tape Blade
HP StorageWorks SB920c Tape Blade
440947-B21
AJ401A
HP PCI Express Mezzanine pass-thru card for HP BladeSystem
431643-B21
NOTE: The HP PCI Express Mezzanine Pass-Thru Card for HP BladeSystem (431643-
B21) is required when installing a tape blade adjacent to a full-height server blade
NOTE: Please see the HP Tape Blades QuickSpecs for additional options and
configuration information at:
HP PCI Expansion Blade PCI Expansion Blade
448018-B21
AG780A
NOTE: For additional information regarding the HP PCI Expansion Blade, please visit:
HP StorageWorks AIO
HP StorageWorks AiO SB600c Storage Blade – 1.16TB
SB600c shared storage NOTE: Shared storage blade for server blades within the enclosure. The SB600c can
blade
be either NAS (file-based shared storage or iSCSI Shared Storage connected to server
blades within the enclosure using an Ethernet switch in the enclosures interconnect
bays.
NOTE: For additional information regarding the HP StorageWorks AiO SB600c
Storage Blade, please visit:
HP StorageWorks Storage Mirroring for AiO Edition Software
NOTE: This optional software is for mirroring data between AiO Storage blades in
different locations. This is host-based data replication software for disaster recovery
and data protection.
T5321A
NOTE: Order 1 unit for each AiO SB600c Storage Blade.
HP Monitored Power
Distribution Unit
HP 8.6 kVA Monitored PDU, 30A (NA/JPN)
HP 11 kVA Monitored PDU 16A (INTL)
AF504A
AF508A
HP Modular Power
Distribution Unit
HP 8.3kVA Modular Distribution Unit 40 Amp (NA/JPN)
HP 8.3kVA Modular Distribution Unit 40 Amp (Intl)
HP 7.3kVA Modular Distribution Unit 32 Amp (Intl)
HP 4.9kVA Modular Distribution Unit 24 Amp (NA/JPN)
HP Two C-13 PDU Extension Bars
252663-D73
252663-B32
252663-B31
252663-D72
AF500A
Optional Power Cords
Power Cord, C20 C13, 15A, Universal Jumper, 2m
NOTE: For use with PDU's that accept C20 power cords.
AF590A
DA - 12790
Worldwide — Version 12 — July 14, 2008
Page 23
QuickSpecs
Related Options
HP BladeSystem c3000 Enclosure
Uninterruptible Power
HP rack-mountable R5500 UPS (5000VA / 4500 watts)
AF426A
Systems - Rack Mountable
NOTE: The R5500 includes four c-13 PDU Extension bars.
NOTE: The R5500 supports 4 power supplies in the Power Supply Redundant (N+1)
power mode.
HP Rack 10000 Series
(Graphite Metallic)
HP S10614 (14U) Rack Cabinet – Shock Pallet
292302-B22
HP Rack 10000 G2 Series10622 G2 (22U) Rack Cabinet Shock
AF022A
AF021A
AF001A
AF002A
AF003A
AF004A
AF007A
AF011A
AF012A
AF013A
AF014A
AF031A
AF042A
AF041A
(Graphite Metallic)
10622 G2 (22U) Rack Cabinet Pallet
10642 G2 (42U) Rack Cabinet – Pallet
10642 G2 (42U) Rack Cabinet – Shock Pallet
10642 G2 (42U) Rack Cabinet – Crated
10642 G2 (42U) Rack Cabinet, with Extension – Shock Pallet
10642 G2 (42U) Rack Shock Pallet – for field racking (NA only)
10636 G2 (36U) Rack Cabinet – Shock Pallet
10636 G2 (36U) Rack Cabinet – Crated
10636 G2 (36U) Rack Cabinet, with Extension – Shock Pallet
10636 G2 (36U) Rack Cabinet, without door – Shock Pallet
10647 G2 (47U) Rack Cabinet – Pallet
10842 G2 (42U) Rack Cabinet Shock
10842 G2 (42U) Rack Cabinet Pallet
NOTE: Please see the Rack 10000 G2 QuickSpecs for additional part numbers and
Technical Specifications such as height, width, depth, weight, and color:
(Worldwide)
NOTE: For additional information regarding Rack Cabinets, please see the following
Rack Options for Rack
10000 G2 Series
HP 10642 G2 Front Door ALL
HP 10636 G2 Front Door ALL
10642 G2 (42U) Side Panels (set of two) (Graphite Metallic)
10636 G2 (36U) Side Panels (set of two) (Graphite Metallic)
10642 Rear Extension Kit
AF009A
AF019A
AF054A
AF056A
AF058A
AF060A
AF062A
AF068A
10636 G2 Rear Extension Kit
600mm G2 Stabilizer Option Kit (Graphite)
800mm G2, Heavy Duty Stabilizer Option Kit (Graphite)
NOTE: Supports 10000 G2 Series only.
HP 10000 G2 Rack Grounding Kit
AF074A
AF076A
600W 10K G2 Rack Tie Down
NOTE: For additional information regarding Rack Options, please see the following
DA - 12790
Worldwide — Version 12 — July 14, 2008
Page 24
QuickSpecs
Related Options
HP BladeSystem c3000 Enclosure
HP Modular Cooling
System
HP Modular Cooling System
AF098A
Data Protection
The following options are supported in an Enterprise Backup Solution (EBS)
environment with the HP BladeSystem c-Class enclosure. Please visit:
http://www.hp.com/go/ebs for complete compatibility details.
HP StorageWorks MSL2024 Tape Library
HP StorageWorks MSL2024 1 LTO-4 Ultrium 1840 SCSI Drive Library
HP StorageWorks MSL2024 1 LTO-4 Ultrium 1840 4GB FC Library
HP StorageWorks MSL2024 1 LTO-4 Ultrium 1760 SCSI Drive Library
HP StorageWorks MSL2024 1 LTO-3 Ultrium 960 SCSI Drive Library
HP StorageWorks MSL2024 1 LTO-3 Ultrium 960 4GB FC Library
HP StorageWorks MSL2024 1 LTO-3 Ultrium 920 SCSI Drive Library
HP StorageWorks MSL2024 2 LTO-3 Ultrium 920 SCSI Drive Library
HP StorageWorks MSL2024 1 LTO-2 Ultrium 448 SCSI Drive Library
HP StorageWorks MSL2024 2 LTO-2 Ultrium 448 SCSI Drive Library
HP StorageWorks MSL4048 Tape Library
AJ033A
AJ034A
AJ817A
AG115A
AG326B
AH169A
AH170A
AG116A
AG117A
HP StorageWorks MSL4048 1 LTO-4 Ultrium 1840 SCSI Drive Library
HP StorageWorks MSL4048 2 LTO-4 Ultrium 1840 SCSI Drive Library
HP StorageWorks MSL4048 1 LTO-4 Ultrium 1840 4GB FC Library
HP StorageWorks MSL4048 2 LTO-4 Ultrium 1840 4GB FC Library
HP StorageWorks MSL4048 2 LTO-4 Ultrium 1760 SCSI Drive Library
HP StorageWorks MSL4048 1 LTO-2 Ultrium 448 SCSI Drive Library
HP StorageWorks MSL4048 2 LTO-2 Ultrium 448 SCSI Drive Library
HP StorageWorks MSL4048 1 LTO-3 Ultrium 920 SCSI Tape Library
HP StorageWorks MSL4048 2 LTO-3 Ultrium 920 SCSI Tape Library
HP StorageWorks MSL4048 1 LTO-3 Ultrium 960 SCSI Drive Library
HP StorageWorks MSL4048 1 LTO-3 Ultrium 960 4GB FC Library
HP StorageWorks MSL4048 2 LTO-3 Ultrium 960 SCSI Drive Library
HP StorageWorks MSL4048 2 LTO-3 Ultrium 960 4GB FC Library
HP StorageWorks MSL8096 Tape Library
AJ035A
AJ037A
AJ036A
AJ038A
AJ818A
AG320A
AG321A
AH171A
AH172A
AG322A
AG324B
AG323A
AG325B
HP StorageWorks MSL8096 2 LTO-4 Ultrium 1840 SCSI Drive Library
HP StorageWorks MSL8096 2 LTO-4 Ultrium 1840 4GB FC Library
HP StorageWorks MSL8096 2 LTO-3 Ultrium 960 4GB FC Library
HP StorageWorks MSL8096 2 LTO-3 Ultrium 960 SCSI Library
NOTE: Please reference the MSL Tape Library QuickSpecs at:
http://www.hp.com/go/automation for additional information needed to create a
complete solution; reference current compatibility information at:
AJ039A
AJ040A
AH218A
AH219A
HP D2D Backup Systems
HP StorageWorks D2D4004i Backup System
NOTE: 4.5TB of Disk Storage
HP StorageWorks D2D4009i Backup System
NOTE: 9TB of Disk Storage
EH938A
EH939A
EH941A
HP StorageWorks D2D4004fc Backup System
NOTE: 4.5TB of Disk Storage
DA - 12790
Worldwide — Version 12 — July 14, 2008
Page 25
QuickSpecs
Related Options
HP BladeSystem c3000 Enclosure
HP StorageWorks D2D4009fc Backup System
NOTE: 9TB of Disk Storage
HP StorageWorks D2D2503i Backup System
NOTE: 3TB of Disk Storage
EH942A
EH945A
NOTE: Please see the HP D2D Backup Systems QuickSpecs for additional
HP StorageWorks Virtual Library Systems
HP StorageWorks 12000 Virtual Library System Gateway Base Library
HP StorageWorks VLS12000 Data Dedupe Capacity LTU (2.0TB)
HP StorageWorks 9030 Virtual Library System
HP StorageWorks VLS9000 Data Dedupe Capacity LTU
HP StorageWorks 6218 Virtual Library System
HP StorageWorks 6227 Virtual Library System
HP StorageWorks 6636 Virtual Library System
HP StorageWorks 6653 Virtual Library System
HP StorageWorks VLS6000 Data Dedupe Capacity LTU
NOTE: Please reference the Virtual Library Systems QuickSpecs at:
http://www.hp.com/go/automation for additional information needed to create a
complete solution. Reference current compatibility information at:
AH814A
T9709A
AG306A
T9708A
AH809A
AH810A
AH811A
AH812A
T9707A
Monitors and Keyboards TFT7600 Rackmount Keyboard Monitor US
AG052A
AG053A
AG055A
AG057A
AG058A
AG059A
AG061A
AG063A
AG065A
AG066A
AG072A
AG073A
AG074A
AG075A
AG076A
AG077A
AG078A
AG079A
AG080A
AG081A
AG082A
AG083A
AG084A
AG085A
AG086A
TFT7600 Rackmount Keyboard Monitor UK
TFT7600 Rackmount Keyboard Monitor FR
TFT7600 Rackmount Keyboard Monitor SP
TFT7600 Rackmount Keyboard Monitor DEN
TFT7600 Rackmount Keyboard Monitor NOR
TFT7600 Rackmount Keyboard Monitor SWI
TFT7600 Rackmount Keyboard Monitor BEL
TFT7600 Rackmount Keyboard Monitor RUS
TFT7600 Rackmount Keyboard Monitor INTL
1U Rackmount Keyboard with USB, US
1U Rackmount Keyboard with USB, UK
1U Rackmount Keyboard with USB, GR
1U Rackmount Keyboard with USB, FR
1U Rackmount Keyboard with USB, ITL
1U Rackmount Keyboard with USB, SP
1U Rackmount Keyboard with USB, DEN
1U Rackmount Keyboard with USB, NOR
1U Rackmount Keyboard with USB, SE/FI
1U Rackmount Keyboard with USB, SWI
1U Rackmount Keyboard with USB, PORT
1U Rackmount Keyboard with USB, BEL
1U Rackmount Keyboard with USB, JPN2
1U Rackmount Keyboard with USB, RUS
1U Rackmount Keyboard with USB, INTL
DA - 12790
Worldwide — Version 12 — July 14, 2008
Page 26
QuickSpecs
Related Options
HP BladeSystem c3000 Enclosure
NOTE: For additional information regarding Rack Options, please see the following
HP KVM Switch Options 2x1x16 IP Console Switch with Virtual Media
4x1x16 IP Console Switch with Virtual Media
2x16 Server Console Switch with Virtual Media
BladeSystem c-Class KVM Interface Adapter - 1 pack
HP 1x8 Server Console Switch
AF601A
AF602A
AF600A
AF605A
336044-B21
336045-B21
HP 2x16 Server Console Switch
NOTE: Cat5e cables are required to connect Interface Adapters to Consoles Switches.
HP 1x4 Console Switch
HP USB Server Console Cable, 6 foot, 2-Pack
AF611A
AF613A
NOTE: required for supporting USB peripherals.
HP USB KVM Cable with audio, 6'-2-pack
371729-B21
NOTE For additional information regarding KVM switches, Serial Console servers,
rack mount monitors, keyboards and all related options please see the following URL:
HP Serial Console Server HP 16 Port Serial Console Server (worldwide)
AF101A
AF102A
AF103A
AF110A
Options
HP 48 Port Serial Console Server (worldwide)
Serial Adapter, RJ45-DB9 DCE Female, 1 Pack
Serial Adapter, RJ45-DB9 DCE Female, 8 Pack
NOTE: Cat5e cables are required to connect Serial Adapters to Serial Console
Servers. Additional Serial Adapters and Cat5e cables can be found at the following
NOTE: For additional information regarding KVM switches, Serial Console servers,
rack mount monitors, keyboards and all related options please see the following URL:
Service and Support
Offerings
NOTE: HP Care Pack services for the c3000 Enclosure cover the enclosure, power
supplies and fans. HP qualified rack options are covered by these services when
(HP Care Pack Services) installed within the same rack. HP supported c-Class enclosure devices including pass
thru, Ethernet interconnect and virtual connect modules are also covered by the c3000
enclosure Care Pack services.
NOTE: SAN/Fabric switches for the HP c-Class BladeSystem are not covered under
the c3000 enclosure Care Packs, SAN/Fabric switches carry separate Care Packs.
SAN/Fabric Switch Care Pack service level support should always be uplifted to match
existing storage or server service level.
Hardware Services On-site Service
Next Business Day On-site Service, 5-Day x 9-Hour Coverage, 3 Years, Electronic
NOTE: Uplifts the Ethernet devices to the same level of warranty as the c-class
enclosure.
UH309E
4-Hour On-site Service, 5-Day x 13-Hour Coverage, 3 Years, Electronic
4-Hour On-site Service, 7-Day x 24-Hour Coverage, 3 Years, Electronic
6-Hour Call to Repair, On-site Service, 7-Day x 24-Hour Coverage, 3 Years,
Electronic
UH310E
UH311E
UH312E
DA - 12790
Worldwide — Version 12 — July 14, 2008
Page 27
QuickSpecs
Related Options
HP BladeSystem c3000 Enclosure
Support Plus 24
Onsite HW support 24x7, 4-Hour response and Insight Control Environment for
BladeSystem Software Updates and Software Technical support offsite, onsite at HP's
discretion, 24x7 2-Hour response time including. HP holidays, Electronic
Installation & Start-up Services
UF540E
HP BladeSystem c3000 + ICE + OS Installation and Startup Service for Blade
Hardware and Insight Control Software, Electronic
HP BladeSystem c3000 Installation & Startup for Blade Hardware and Operating
System
UF817E
UF818E
HP BladeSystem c3000 Enhanced Network Installation and Startup Service, Electronic
ProLiant BL c-Class Enclosure and Blade Hardware Installation, Electronic
ProLiant BL c-Class Blade Server Hardware Installation, Electronic
UF814E
UE494E
UE493E
NOTE: For more information, customer/resellers can contact:
NOTE: The HP Care Pack service part numbers below covers the HP Brocade 4Gb,
12 Port SAN Switch and Brocade 4/24 SAN Switch.
Hardware Services On-site Service
Next Business Day On-site Service, 5-Day x 9-Hour Coverage,3 Years, Electronic
4-Hour On-site Service, 5-Day x 13-Hour Coverage, 3 Years, Electronic
4-Hour On-site Service, 7-Day x 24-Hour Coverage, 3 Years, (24 port) Electronic
6-Hour Call to Repair, On-site Service, 7-Day x 24-Hour Coverage, 3 Years,
Electronic
UE436E
UE437E
UE438E
UE439E
Hardware Installation, Electronic
U5988E
NOTE: The HP Care Pack service part numbers below covers the Brocade 4/24 SAN
Switch Power Pack.
Hardware Services On-site Service
Support Plus
Onsite Hardware support, 8am-9pm, M-F, 4-hour response and Software Technical
support offsite, onsite at HP's discretion, 8am-9pm, M-F 2-hour response time
excluding HP holidays, Electronic
UE728E
UE729E
Support Plus 24
Onsite Hardware support, 8am-9pm, M-F, 4-Hour response and Software Technical
support offsite, onsite at HP's discretion, 8am-9pm, M-F 2-Hour response time
excluding. HP holidays, Electronic
NOTE: The HP Care Pack service part numbers below covers the HP Cisco MDS
9124e 12 port and 24 port Fabric Switch.
Hardware Services On-site Service
Next Business Day On-site Service, 5-Day x 9-Hour Coverage, 3 Years, Electronic
4-Hour On-site Service, 5-Day x 13-Hour Coverage, 3 Years, Electronic
4-Hour On-site Service, 7-Day x 24-Hour Coverage, 3 Years, Electronic
6-Hour Call to Repair, On-site Service, 7-Day x 24-Hour Coverage, 3 Years,
Electronic
UF313E
UF972E
UF973E
UF974E
Hardware Installation, Electronic
Software Installation and StartUp Services
Provides for the Installation and Start-up of ProLiant Essentials Rapid Deployment
Pack, Electronic
U5988E
U5683E
DA - 12790
Worldwide — Version 12 — July 14, 2008
Page 28
QuickSpecs
Related Options
HP BladeSystem c3000 Enclosure
NOTE: Provides installation on a Customer supplied server designated as a
Deployment Server. Includes the deployment of a single server. This new server will be
deployed using either one of the pre-configured scripts or an image. In addition, the
service will provide for the capture and storage of the configuration of the newly
deployed server and orientation on product usage. To be delivered during standard
office ours, standard office days.
Provides for the Installation and Start-up of Rapid Deployment Pack Implementation of
Rapid Deployment Pack (Basic), Electronic
UA042E
NOTE: Service coverage: onsite installation of the Vulnerability and Patch
Management (VPM) software on a customer designated server, configuration of the
VPM software to acquire security patches, enabling the VPM software to scan up to five
(5) systems, applying the security patches to the designated servers, generating a
report from VPM that shows the vulnerability assessment results, and providing
customer with an orientation to the software.
Provides for the Installation and Start-up of System Insight Manager (Electronic)
Provides for the Installation and Start-up of System Insight Manager Agents (Electronic)
Provides for the Installation and Startup of Insight Control – Linux Edition
Provides for the Installation and Startup of Virtual Machine Management & Server
Migration Pack
UA041E
UA040E
UF369E
UD546E
Software Operating Environment Care Packs
1 Year Microsoft operating environment software support 24x7 – 10 incidents
1 Year Red Hat operating System software support 24x7 – 10 incidents
1 Year SuSE operating System software support 24x7 – 10 incidents
1 Year 9x5 ProLiant Essentials Software Support
1 Year 24x7 ProLiant Essentials Software Support
3 Year 9x5 ProLiant Essentials Software Support
U9269E
U3408E
U9936E
UF512E
UF513E
UF514E
UF515E
HP 3 Year 24x7 ProLiant Essentials Software Support
NOTE: For more information, customer/resellers can contact:
NOTE: HP Care Pack services for the c3000 Enclosure cover the enclosure, power
supplies and fans. HP qualified rack options are covered by these services when
installed within the same rack. HP supported c-Class enclosure devices including pass
thru, Ethernet interconnect and virtual connect modules are also covered by the c7000
enclosure Care Pack services.
NOTE: SAN/Fabric switches for the HP c-Class BladeSystem are not covered under
the c7000 enclosure Care Packs, SAN/Fabric switches carry separate Care Packs.
SAN/Fabric Switch Care Pack service level support should always be uplifted to match
existing storage or server service level.
Hardware Services On-site Service
Next Business Day On-site Service, 5-Day x 9-Hour Coverage, 3 Years, Electronic
NOTE: Uplifts the Ethernet devices to the same level of service as the c-class enclosure
4-Hour On-site Service, 5-Day x 13-Hour Coverage, 3 Years, Electronic
4-Hour On-site Service, 7-Day x 24-Hour Coverage, 3 Years, Electronic
6-Hour Call to Repair, On-site Service, 7-Day x 24-Hour Coverage, 3 Years,
Electronic
HA101A3#6X4
HA103A3#6X4
HA104A3#6X4
HA105A3#6X4
Support Plus
Onsite HW support, 8am-9pm, M-F, 4hr response and SW Tech support offsite, onsite HA109A3#6X4
at HP's discretion, 8am-9pm, M-F 2hr response time excl. HP holidays, 3 Years
DA - 12790
Worldwide — Version 12 — July 14, 2008
Page 29
QuickSpecs
Related Options
HP BladeSystem c3000 Enclosure
Support Plus 24 - Onsite HW support 24x7, 4hr response and SW support offsite,
onsite at HP's discretion, 24x7 2hr response time incl. HP holidays, 3 Year
Proactive 24 Service - Mission Critical proactive environment 24x7 4hr onsite HW
support, 3 Years
Critical Service - Mission Critical proactive environment 6-Hour Call-to-Repair onsite
HW support, 3 Years
HA110A3#6X4
HA111A3#6X4
HA112A3#6X4
Installation & Start-up Services
HP BladeSystem c3000 Hard Ware Installation
HP BladeSystem c3000 Infrastructure Installation and Startup Service for Blade
Hardware and Insight Control Software
HA113A1#57A
HA114A1#57A
NOTE: For more information, customer/resellers can contact:
NOTE: The HP Care Pack service part numbers below covers the HP Brocade 4Gb,
12 Port SAN Switch and Brocade 4/24 SAN Switch.
Hardware Services On-site Service
Next Business Day On-site Service, 5-Day x 9-Hour Coverage, 3 Years
4-Hour On-site Service, 5-Day x 13-Hour Coverage, 3 Years
4-Hour On-site Service, 7-Day x 24-Hour Coverage, 3 Years
6-Hour Call to Repair, On-site Service, 7-Day x 24-Hour Coverage, 3 Years,
Electronic
HA101A3#85J
HA103A3#85J
HA104A3#85J
HA105A3#85J
Hardware Installation, Electronic
HA113A1#5D2
NOTE: The HP Care Pack service part numbers below covers the Brocade 4/24 SAN
Switch Power Pack.
Hardware Services On-site Service
Support Plus
Onsite HW support, 8am-9pm, M-F, 4hr response and SW Tech support offsite, onsite HA109A3#85K
at HP's discretion, 8am-9pm, M-F 2hr response time excluding HP holidays, Electronic
Support Plus 24
Onsite HW support 24x7, 4hr response and SW Tech support offsite, onsite at HP's
discretion, 24x7 2hr response time including HP holidays, Electronic
NOTE: The HP Care Pack service part numbers below covers the HP Cisco MDS
9124e 12 port and 24 port Fabric Switch.
HA110A3#85K
Hardware Services On-site Service
Next Business Day On-site Service, 5-Day x 9-Hour Coverage, 3 Years
4-Hour On-site Service, 5-Day x 13-Hour Coverage, 3 Years
4-Hour On-site Service, 7-Day x 24-Hour Coverage, 3 Years
6-Hour Call to Repair, On-site Service, 7-Day x 24-Hour Coverage, 3 Years,
Electronic
HA101A3#87L
HA103A3#87L
HA104A3#87L
HA105A3#87L
Hardware Installation, Electronic
HA113A1#5D2
NOTE: For more information, customer/resellers can contact:
DA - 12790
Worldwide — Version 12 — July 14, 2008
Page 30
QuickSpecs
Technical Specifications
HP BladeSystem c3000 Enclosure
Server Blade, Power Supply and Fan Population Guidelines
Fan & power supply bay numbering
HP BladeSystem c3000 Enclosure – Rack
Fan bay numbering
HP BladeSystem c3000 Enclosure – Tower
DA - 12790
Worldwide — Version 12 — July 14, 2008
Page 31
QuickSpecs
Technical Specifications
HP BladeSystem c3000 Enclosure
HP BladeSystem c3000 Enclosure – Rack
Power supply bay numbering
HP BladeSystem c3000 Enclosure – Tower
Power Supplies & Fans must be placed in the following bays
Number of Fans
4
6
Fan Bays Used
2,4,5, 6
all bays filled
Number of Power Supplies (for PS Redundant or non-redundant Power Supply Bays Used
mode)
2
1 & 2
3
1, 2, & 3
4
1, 2, 3, 4
5
6
1 through 5
All bays
Number of Power Supplies (For AC Redundant mode)
Place Power Supplies in bays:
1 & 4
1, 2, 4, & 5
all bays filled
2
4
6
NOTE: With four fans, the enclosure will support only 4 half-Height Server blades in the bottom half of the enclosure device bays.
With six fans, all 8 server bays may be filled.
NOTE: For correct operation, fans and server blades must be installed in the correct bays. The Onboard Administrator will ensure
that fans and blades are correctly placed before allowing systems to power on.
Half-height server blade bay numbering
DA - 12790
Worldwide — Version 12 — July 14, 2008
Page 32
QuickSpecs
Technical Specifications
HP BladeSystem c3000 Enclosure
HP BladeSystem c3000 Enclosure – Racks
1. Device Bay 1
2. Device Bay 2
3. Device Bay 3
4. Device Bay 4
5. Device Bay 5
6. Device Bay 6
7. Device Bay 7
8. Device Bay 8
HP BladeSystem c3000 Enclosure – Tower
1. Device Bay 1
2. Device Bay 2
3. Device Bay 3
4. Device Bay 4
5. Device Bay 5
6. Device Bay 6
7. Device Bay 7
8. Device Bay 8
NOTE: Half-height server blades should be populated from the bottom half of the enclosure, in the following order (bays 1, 5, 2, 6,
3, 7, 4, & 8)
Full-height server blade bay numbering
HP BladeSystem c3000 Enclosure – Racks
1. Device Bay 1
HP BladeSystem c3000 Enclosure – Tower
1. Device Bay 1
2. Device Bay 2
2. Device Bay 2
3. Device Bay 3
3. Device Bay 3
4. Device Bay 4
4. Device Bay 4
NOTE: Full-height servers should be populated from the bottom to the top (bays 1 thru 4). With four fans, only the bottom 2 bays
can be used; with six fans, all bays can be used.
DA - 12790
Worldwide — Version 12 — July 14, 2008
Page 33
QuickSpecs
Technical Specifications
HP BladeSystem c3000 Enclosure
Mixed Configuration – Full Height and Half Height Population
The c3000 enclosure is divided into 2 zones or quadrants by the horizontal (vertical on Tower model) support metalwork. Zone 1
includes bays 1, 2, 4, & 5; and Zone 2 contains bays 3, 4, 7, & 8. Within each zone a removable divider is used to support half
height devices. To install a full-height blade in any zone this divider must be removed. An optional mini-divider support bracket is
included with every c3000 enclosure. As a consequence of using the mini-divider in the Zone 2, this zone can only contain one full
height blade and 2 half-height blades. Zone 1 can contain either 4 half-height blades, or by removing the divider, it can contain 2
full-height blades.
NOTE: Please read the RTF card (included with each c3000 enclosure) and the "HP BladeSystem c3000 Setup and Installation
Guide" for more information on using bay dividers and the mini-divider for mixed configurations.
NOTE: Storage or tape blades can be installed in the same zone as both full-height and half-height blades, a bracket ships with
each SB40c that allows a half-height blade to be mounted to the left side of a storage or tape blade.
NOTE: In this case, the SB40c or tape blade cannot be removed without first removing the half height blade and mounting bracket.
NOTE: For Mixed configurations of full height and half height population rules; please see the c3000 Enclosure installation and
Enclosure Unit –
Rack Model
Dimensions (H x W x D) 10.4 x 19.1 x 32.977 in (265 x 485 x 835 mm)
(with bezel)
Weight
Maximum
300 lb (136 kg)
(approximate)
(one enclosure with 8
blades and 4 interconnects
installed)
Minimum
130 lb (59 kg)
(one enclosure without
blades and interconnects)
Input Requirements
(per AC power supply)
Rated Line Voltage
90 – 132 VAC
180 – 264 VAC
Rated Input Current
9.3 A (at 100 VAC)
9.7 A (at 120VAC)
7.8 A (at 200 VAC)
7.2 A (at 208 VAC)
6.8 A (at 220 VAC)
6.2 A (at 240 VAC)
Rated Input Frequency
47 to 63 Hz
BTU Rating
Maximum per power
supply
2728 BTU/hr (at 100 VAC)
3069 BTU/hr (at 120VAC)
4092 BTU/hr (at 200 to 240 VAC)
Power Specifications
To review typical system power ratings use the Power Calculator which is
available via the online tool located at URL:
Power Supply Output
(per power supply)
Rated Steady-State Power 800 W (at 100 VAC)
900 W (at 120 VAC)
1200 W (at 200 to 240 VAC)
Maximum Peak Power
880 W (at 100 VAC)
990 W (at 120 VAC)
1350 W (at 200 to 240 VAC)
DA - 12790
Worldwide — Version 12 — July 14, 2008
Page 34
QuickSpecs
Technical Specifications
HP BladeSystem c3000 Enclosure
System Inlet Temperature Operating
10° to 35°C (50° to 95°F) at sea level with an
altitude derating of 1.0°C per every 305 m
(1.8°F per every 1000 ft) above sea level to a
maximum of 3050 m (10,000 ft), no direct
sustained sunlight. Maximum rate of change is
10°C/hr (18°F/hr). The upper limit may be
limited by the type and number of options
installed. System performance may be reduced if
operating with a fan fault or above 30°C (86°F).
Non-operating
Operating
-30° to 60°C (-22° to 140°F). Maximum rate of
change is 20°C/hr (36°F/hr).
Relative Humidity
(non-condensing)
10 to 90% relative humidity (Rh), 28°C (82.4°F)
maximum wet bulb temperature, non-
condensing.
Non-operating
Operating
5 to 95% relative humidity (Rh), 38.7°C
(101.7°F) maximum wet bulb temperature, non-
condensing.
Altitude
3050 m (10,000 ft). This value may be limited by
the type and number of options installed.
Maximum allowable altitude change rate is 457
m/min (1500 ft/min).
Non-operating
9144 m (30,000 ft). Maximum allowable
altitude change rate is 457 m/min (1500 ft/min).
Acoustic Noise
Listed are the declared A-Weighted sound power levels (LWAd) and declared
average bystander position A-Weighted sound pressure levels (LpAm) when
the product is operating in a 23°C ambient environment. Noise emissions
were measured in accordance with ISO 7779 (ECMA 74) and declared in
accordance with ISO 9296 (ECMA 109).
Idle
depends on server configuration & mix of server
blades
Operating
varies by CPU utilization, server configuration,
and mix of server blades
Enclosure Unit – Tower
Model
Dimensions (H x W x D) 21.29 x 13.48 x 34.43 in (54.08 x 34.24 x 87.45 cm)
(with bezel)
Weight
Maximum
342 lb (155 kg)
(approximate)
(all server blades and
interconnects installed)
Minimum
192 lb (87.09 kg)
(2 power supplies & 4
fans, no server blades nor
interconnects installed)
Input Requirements
(per AC power supply)
Rated Line Voltage
90 – 132 VAC
180 - 264 VAC
DA - 12790
Worldwide — Version 12 — July 14, 2008
Page 35
QuickSpecs
Technical Specifications
HP BladeSystem c3000 Enclosure
Rated Input Current
9.3 A (at 100 VAC)
9.7 A (at 110 VAC)
7.8 A (at 200 VAC)
7.2 A (at 208 VAC)
6.8 A (at 220 VAC)
6.2 A (at 240 VAC)
Rated Input Frequency
47 to 63 Hz
BTU Rating
Maximum per power
supply
2728 BTU/hr (at 100 VAC)
3069 BTU/hr (at 120VAC)
4092 BTU/hr (at 200 to 240 VAC)
Power Specifications
To review typical system power ratings use the Power Calculator which is
available via the online tool located at URL: :
Power Supply Output
(per power supply)
Rated Steady-State Power 800 W (at 100 VAC),
900 W (at 120 VAC)
1200 W (at 200 to 240 VAC)
Maximum Peak Power
880 W (at 100 VAC),
990 W (at 120 VAC)
1350 W (at 200 to 240 VAC)
System Inlet Temperature Operating
10° to 35°C (50° to 95°F) at sea level with an
altitude derating of 1.0°C per every 305 m
(1.8°F per every 1000 ft) above sea level to a
maximum of 3050 m (10,000 ft), no direct
sustained sunlight. Maximum rate of change is
10°C/hr (18°F/hr). The upper limit may be
limited by the type and number of options
installed. System performance may be reduced if
operating with a fan fault or above 30°C (86°F).
Non-operating
Operating
-30° to 60°C (-22° to 140°F). Maximum rate of
change is 20°C/hr (36°F/hr).
Relative Humidity
(non-condensing)
10 to 90% relative humidity (Rh), 28°C (82.4°F)
maximum wet bulb temperature, non-
condensing.
Non-operating
Operating
5 to 95% relative humidity (Rh), 38.7°C
(101.7°F) maximum wet bulb temperature, non-
condensing.
Altitude
3050 m (10,000 ft). This value may be limited by
the type and number of options installed.
Maximum allowable altitude change rate is 457
m/min (1500 ft/min).
Non-operating
9144 m (30,000 ft). Maximum allowable
altitude change rate is 457 m/min (1500 ft/min).
Acoustic Noise
Listed are the declared A-Weighted sound power levels (LWAd) and declared
average bystander position A-Weighted sound pressure levels (LpAm) when
the product is operating in a 23°C ambient environment. Noise emissions
were measured in accordance with ISO 7779 (ECMA 74) and declared in
accordance with ISO 9296 (ECMA 109).
Idle
depends on server configuration & mix of server
blades
DA - 12790
Worldwide — Version 12 — July 14, 2008
Page 36
QuickSpecs
Technical Specifications
HP BladeSystem c3000 Enclosure
Operating
varies by CPU utilization, server configuration,
and mix of server blades
Option Kits
Power Supply Dimensions Size
Height: 1.515 in (38.48 mm)
Width: 3.4 in (86.36 mm)
Depth: 7.5 in (190.5 mm)
2.5 lbs (1.13 kg)
Height: 8.75 in (223 mm)
Width: 9.75 in (248 mm)
Depth: 15.88 in (403 mm)
4.0 lbs (1.8 Kg)
Weight
Size
Fan Option Shipping
Dimensions
Weight
NOTE: To review maximum system power ratings for facilities planning purposes use the Active Answers Power Calculator which is
Environment-friendly
End-of-life Management Hewlett-Packard offers end-of-life HP product return, trade-in, and recycling
Products and Approach and Recycling
programs in many geographic areas. For trade-in information, please go to
http://www.hp.com/go/green. To recycle your product, please go to:
http://www.hp.com/go/green or contact your nearest HP sales office.
Products returned to HP will be recycled, recovered or disposed of in a
responsible manner.
The EU WEEE directive (2002/95/EC) requires manufacturers to provide
treatment information for each product type for use by treatment facilities.
This information (product disassembly instructions) is posted on the Hewlett
used by recyclers and other WEEE treatment facilities as well as HP OEM
customers who integrate and re-sell HP equipment.
© Copyright 2008 Hewlett-Packard Development Company, L.P.
The information contained herein is subject to change without notice.
Microsoft and Windows NT are US registered trademarks of Microsoft Corporation. Intel, the Intel logo, Xeon and Xeon Inside are
trademarks of Intel Corporation in the U.S. and other countries. AMD is a US registered trademark of AMD Corporation.
The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and
services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial
errors or omissions contained herein.
DA - 12790
Worldwide — Version 12 — July 14, 2008
Page 37
|