Gas hobs
INSTRUCTION BOOKLET
Please read this instruction booklet before using the appliance
EPGH
GB
35674-8901
Contents
For the Installer
Engineers technical data
Installation
For the User
9
10
11
12
13
13
15
15
Important Safety Information
Description of the Hob
Operation
2
3
4
4
5
6
6
Building In
Electrical connections
Wiring Diagram
Maintenance and Cleaning
Something Not Working?
Service and Spare Parts
Guarantee Conditions
Fault Finding
Commissioning
Conversion from Natural Gas to LPG
Description of the Hob
3
3
2
1
4
5
6
1. Hob Top
2. RapidBurner
3. Semi-rapid Burners
4. AuxiliaryBurner
5. Controlknobs
6. Ignitionpushbutton
3
Operation
HOBBURNERS
To light a burner, turn the relevant control knob
anticlockwise to maximum position. At the same time
pushtheelectricignitionpushbuttonwhichismarkedby
a little spark. Then adjust the flame as required.
If the burner does not ignite, turn the control knob to
zero, and try again.
To ensure maximum burner efficiency, you should only
use pots and pans with a flat bottom fitting the size of
the burner used (see table).
If you use a saucepan which is smaller than the
recommended size, the flame will spread beyond
the bottom of the vessel, causing the handle to
overheat.
As soon as a liquid starts boiling, turn down the
flame so that it will barely keep the liquid
simmering.
Burner
minimum
diameter
maximum
diameter
Large(rapid)
Medium(semi-rapid)
Small (Auxiliary)
180 mm.
120 mm.
80 mm.
260 mm.
220 mm.
160 mm.
Maintenance and Cleaning
Before any maintenance or cleaning can be carried
out, you must DISCONNECT the hob from the
electricity supply.
The hob is best cleaned whilst it is still warm, as
spillage can be removed more easily than if it is
left to cool.
The Hob Top
Regularly wipe over the hob top using a soft cloth well
wrungoutinwarmwatertowhichalittlewashingupliquid
has been added. Avoid the use of the following:
-householddetergentandbleaches;
- impregnated pads unsuitable for non-stick saucepans;
- steel wool pads;
- bath/sink stain removers.
Should the hob top become heavily soiled, it is
recommendedthatacleaningproductsuchasHobBrite
or Bar Keepers Friend is used.
Pan Supports
Thepansupportsaredishwasherproof. Ifwashingthem
by hand, take care when drying them as the enamelling
process occasionally leaves rough edges. If necessay,
remove stubborn stains using a paste cleaner.
The Burners
Theburnercapsandcrownscanberemovedforcleaning.
Washtheburnercapsandcrownsusinghotsoapywater,
and remove marks with a mild paste cleaner. A well
moistenedsoapimpregnatedsteelwoolpadcanbeused
with caution, if the marks are particularly difficult to
remove.
After cleaning, be sure to wipe dry with a soft cloth.
4
Something Not Working?
If the hob is not working correctly, please carry out the following checks before contacting your local Service Force
Centre.
IMPORTANT: If you call out an engineer to a fault listed below, or to repair a fault caused by incorrect use or
installation, a charge will be made even if the appliance is under guarantee.
SYMPTOM
SOLUTION
n There is no spark when lighting the gas
u Check that the unit is plugged in and the electrical
supply is switched on
u Check that the RCCB has not tripped (if fitted)
u Check the mains fuse has not blown
u Check the burner cap and crown have been
replaced correctly, e.g. after cleaning.
n The gas ring burns unevenly
u Check the main jet is not blocked and the burner
crown is clear of food particles.
u Check the burner cap and crown have been
replaced correctly, e.g. after cleaning.
If after all these checks, your hob still does not operate
correctly, contact your local Service Force Centre.
In-guarantee customers should ensure that the
above checks have been made as the engineer will
make a charge if the fault is not a mechanical or
electrical breakdown.
Please note that it will be necessary to provide proof of
purchase for any in-guarantee service calls.
Service and Spare Parts
CUSTOMER CARE
For general enquiries concerning your appliance, contact
our Customer Care Department by letter or telephone as
follows:
If you require spare parts or an engineer contact your
local Service Force Centre by telephoning:
Customer Care Department
ELECTROLUX
0870 5 929929
Your call will be routed to the Service Centre covering
your post code area. The addresses of Electrolux Service
Forces Centres are detailed on the following pages.
55-77 High Street
Slough
Berkshire, SL1 1DZ
Tel: 08705-950950*
When you contact the Service Centre, they will need the
following information:
1. Your name, address and post code.
2. Your telephone number
3. Clear and concise details of the fault
4. The model and the serial number (see rating label on
the back of this instruction booklet)
5. Date of purchase
* calls to this number may be recorded for training
purposes.
5
Guarantee Conditions
Electrolux Standard Guarantee
Conditions
European Guarantee
If you should move to another country within Europe then
your guarantee moves with you to your new home
subject to the following qualifications:
We, Electrolux, undertake that if, within 12 months of
the date of the purchase, this Electrolux appliance or
any part thereof is proved to be defective by any reason
only of faulty workmanship or materials, we will, at our
option, repair or replace the same FREE OF ANY
CHARGE for labour, materials or carriage on condition
that:
*
The guarantee starts from the date you first
purchased your product.
*
The guarantee is for the same period and to the same
extent for labour and parts as exist in the new country
of use for this brand or range of products.
*
*
*
This guarantee relates to you and cannot be
transferred to another user.
*
*
*
The appliance has been correctly installed and used
only on the gas and electricity supply stated on the
rating plate.
Your new home is within the European Community
(EC) or European Free Trade Area.
The appliance has been used for normal domestic
purposes only, and in accordance with the
manufacturer's instructions.
The product is installed and used in accordance with
our instructions and is only used domestically, i.e. a
normal household
The appliance has not been serviced, maintained,
repaired, taken apart or tampered with by any person
not authorised by us.
*
*
The gas type and the gas supply pressure comply
with the specification given in the rating label
The product is installed taking into account
regulations in your new country.
*
*
*
All service work under this guarantee must be
undertaken by a Electrolux Service Force Centre.
Before you move, please contact your nearest Customer
Care centre, listed below, to give them details of your
new home. They will then ensure that the local Service
Organisation is aware of your move and able to look after
you and your appliances.
Any appliance or defective part replaced shall
become the Company's property.
This guarantee is in addition to your statutory and
other legal rights.
Home visits are made between 8.30am and 5.30pm
Monday to Friday. Visit may be available outside these
hours, in which case a premium will be charged.
France
Germany
Italy
Senlis
+33 (0)3 44 62 29 99
+49 (0)911 323 2600
Nürnberg
Pordenone +39 (0)1678 47053
Stockholm +46 (0)8 738 79 50
Sweden
UK
Exclusions
This guarantee does not cover:
Slough
+44 (0)1753 219898
*
*
*
*
Damage or calls resulting from transportation,
improper use or neglect, the replacement of any light
bulbs or removable parts of glass or plastic.
Costs incurred for calls to put right an appliance
which is improperly installed or calls to appliance
outside the United Kingdom.
Appliances found to be in use within a commercial
or similar environment, plus those which are the
subject of rental agreements.
Products of Electrolux manufacture which are not
marketed by Electrolux.
6
ELECTROLUX SERVICE FORCE
To contact your local Electrolux Service Force Centre telephone 08705 929 929
NORTH EAST
CHANNEL ISLANDS
ISLE OF LEWIS
(M69)
ND Macleod
16 James Street
Stornoway
Isle of Lewis
PA872QW
GUERNSEY
Guernsey Electricity
PO Box 4
GATESHEAD
(M39)
Unit 356a
Dukesway Court
Dukesway
Team Valley
Gateshead
NE11 0BH
Vale, Guernsey
Channel Islands
KELSO
(M08)
2-8 Wood Market
Kelso
Borders TD5 7AX
JERSEY
Jersey Electricity
Company
PO Box 45
Queens Road
St Helier
GRIMSBY
(M42)
15 Hainton Avenue
Grimsby
South Humberside
DN32 9AS
ORKNEY
(M65)
Corsie Domestics
7 King Street
Kirkwall
Jersey
Orkney KW15 1RE
Channel Islands
JE4 8NY
HULL
(M41)
Unit 1
Boulevard Industrial
Estate
Hull
HU3 4AY
PERTH
Hydro Electrical
Inveralmond House
Ruthervenfield Road
Perth PH1 3AQ
SCOTLAND
PERTH
(OWN SALES)
Graham Begg Unit 4
Airport Ind Estate
Wick KW1 4QS
LEEDS
(M37)
64-66 Cross Gates
Road
Leeds
LS15 7NN
ABERDEEN
(M05)
54 Claremont Street
Aberdeen
AB10 6RA
SHETLAND
(OWN SALES)
Tait Electronic
Systems Ltd.
Holmsgarth Road
Lerwick
NEWTONAYCLIFFE Unit 16
(M45)
AUCHTERMUCHY
(M03)
33A Burnside
Auchtermuchy
Fife
Gurney Way
Aycliffe Ind Estate
Newton Aycliffe
DL5 6UJ
Shetland ZE1 0PW
KY14 7AJ
SHETLAND
(OWN SALES)
Bolts Shetland Ltd
26 North Road
Lerwick
BLANTYRE
(M07)
Unit 5
Block 2
Auchenraith Industrial
Estate
Rosendale Way
Blantyre
G72 0NJ
SHEFFIELD
(M38)
Pennine House
Roman Ridge Ind.
Shetland ZE1 0PE
Roman Ridge Road
Sheffield
S9 1GB
WHALSAY
Leask Electrical
Harlsdale
Symbister, Whalsay
Shetland ZE2 9AA
(OWN SALES)
DUMFRIES
(M01)
93 Irish Street
Dumfries
Scotland
DG1 2PQ
NORTH WEST
NORTHERN IRELAND
BIRKENHEAD
(M11)
1 Kelvin Park
Dock Road
Birkenhead
L41 1LT
DUNOON
(M 67)
Briar Hill
7 Hill Street
Dunoon
BELFAST
(M27)
Owenmore House
Kilwee Industrial
Estate
Upper Dunmury Lane
Belfast
BT17 0HD
Argyll
PA23 7AL
CARLISLE
(M10)
Unit 7
James Street
Workshops
James Street
Carlisle
GLASGOW
(M04)
20 Cunningham Road
Clyde Estate
Rutherglen,
Glasgow,
G73 1PP
WALES
Cumbria CA2 5AH
CARDIFF
(M28)
Guardian Industrial
Estate
Clydesmuir Road
Tremorfa, Cardiff
CF2 2QS
ISLE OF MAN
(M64)
South Quay Ind.
Estate
Douglas
Isle of Man IM1 5AT
INVERNESS
(M06)
Unit 3B
Smithton Indust. Est.
Smithton
Inverness
IV1 2PD
LIVERPOOL
(M15)
Unit 1
Honeys Green
Precinct
Honeys Green Lane
Liverpool
L12 9JH
CLYWD
(M14)
Unit 6-7 Coed - Parc
Abergele Road
Rhuddlan
ISLE OFARRAN
(OWN SALES)
Arran Domestics
Unit 4 The Douglas
Centre
Brodick
Isle of Arran
KA27 8AJ
Clwyd
Wales
LL18 5UG
MANCHESTER
(M09)
Unit B
Central Industrial
Estate
St Marks Street
Bolton
BL3 6NR
OSWESTRY
(M17)
Plas Funnon
Warehouse
Middleton Road
Oswestry
ISLE OF BARRA
(OWN SALES)
J Zerfah
244 Bruernish
Isle of Barra
Western Islands
HS9 5QY
SY11 2PP
HAVERFORDWEST Cromlech Lodge
(M75)
PRESTON
(M13)
Unit 250
ISLE OF BUTE
(M66)
Walker Engineering
Glenmhor
Upper Serpentine
Road
Rothesay
Isle of Bute
PA20 9EH
Ambleston
Dawson Place
Walton Summit
Bamber Bridge
Preston
Haverfordwest
Pembrokeshire
SA62 5DS
Lancashire
PR5 8AL
DYFED
(M77)
Maes Y Coed
High Mead
Llanybydder
Carmarthenshire
SA40 9UL
STOCKPORT
(M16)
Unit 20 Haigh Park
Haigh Avenue
Stockport
SK4 1QR
7
ELECTROLUX SERVICE FORCE
To contact your local Electrolux Service Force Centre telephone 08705 929 929
SOUTH EAST
LONDON & EAST ANGLIA
MIDLANDS
ASHFORD
(M58)
Unit 2
BECKENHAM
11a Gardener Ind
Estate
Kent House Lane
Beckenham
Kent BR3 1QZ
BIRMINGHAM
(M18)
66 Birch Road East,
Bridge Road
Business
Estate
(M79)
Wyrley Road
Industrial
Estate
Bridge Road
Ashford
Kent
Witton
Birmingham
B67DB
CHELMSFORD
(M47)
Hanbury Road
Widford Ind Estate
Chelmsford
Essex
TN2 1BB
BOURNE
(M44)
Manning Road Ind
Estate
Pinfold Road
Bourne
PE10 9HT
FLEET
(M59)
Unit 1
Redfields Industrial
Estate
Church Crookham
Fleet
Hampshire
GU13 0RD
CM12 3AE
COLINDALE
(M53)
Unit 14
Capital Park
Capital Way
Colindale
BRIDGNORTH
(M72)
65 St.Marys Street
Bridgnorth
Shropshire
WV16 4DR
London NW9 0EQ
HAYWARDS HEATH 21-25 Bridge Road
(M55)
ELTHAM
(M78)
194 Court Road
Mottingham - Eltham
London SE9 4EW
Haywards Heath
Sussex
RH16 1UA
GLOUCESTER
(M23)
101 Rycroft Street
Gloucester
GL1 4NB
ENFIELD
(M49)
284 Alma Road
Enfield
London
EN3 7BB
HEREFORD
(M31)
Unit 3
SOUTH WEST
Bank Buildings
Cattle Market
Hereford
BARNSTAPLE
(M30)
Main Road
Fremington
Barnstaple
North Devon
EX31 2NT
GRAVESEND
(M57)
Unit B4,
Imperial Business
Estate
Gravesend
Kent
DA11 0DL
HE4 9HX
HIGHAMFERRERS
(M51)
30 High Street
Higham Ferrers
Northants
NN10 8BB
BOURNEMOUTH
(M26)
63-65 Curzon Road
Bournemouth
Dorset
HARPENDEN
(M46)
Unit 4
ILKESTON
(M43)
Unit 2
Riverside Estate
Coldharbour Lane
Harpenden
AL5 4UN
Furnace Road
Ilkeston
BH1 4PW
DE7 5EP
BRIDGEWATER
(M35)
6 Hamp Industrial
Estate
Bridgewater
Somerset
LEICESTER
(M22)
Unit 7
LETCHWORTH
(M50)
16-17 Woodsite Ind
Est.
Oaks Industrial Estate
Coventry Road
Narborough
Leicestershire
LE0 5GF
Works Road
Letchworth
Herts
BRISTOL
(M25)
11 Eldon Way
Eldonwall Trading
Bristol
Avon
BS4 3QQ
SG6 1LA
LINCOLN
(M40)
Unit 8 Stonefield Park
Clifton Street
Lincoln
LONDON
(M76)
2/4 Royal Lane
Yiewsley
West Drayton
Middlesex
UB7 8DL
EMSWORTH
(M33)
266 Main Road
Southboure
Emsworth
LN5 8AA
NEWCASTLE
UNDER LYME
(M12)
18-21 Croft Road
Brampton Industrial
Estate
Newcastle under
Lyme
Staffordshire
ST5 0TW
PO10 8JL
MAIDENHEAD
(M60)
Reform Road
Maidenhead -
Berkshire
ISLE OF WIGHT
(M34)
Unit 8
Enterprise Court
Ryde Business Park
Ryde
SL6 8BY
Isle of Wight
PO33 1DB
MOLESEY
(M61)
10 Island Farm
Avenue
West Molesey
Surrey
KT8 2UZ
REDDITCH
(M20)
13 Thornhill Road
North Moons Moat
Redditch
Worcestershire
B98 9ND
NEWTONABBOT
(M29)
Unit 2
Zealley Industrial
Estate
Kingsteignton
Newton Abbot
S. Devon
NEWBURY
(M24)
9 Pipers Court
Berkshire Drive
Thatcham
Berkshire
RG19 4ER
TAMWORTH
(M19)
Unit 3
Sterling Park
Claymore
Tamworth
B77 5DO
TQ12 3TD
PLYMOUTH
(M32)
16 Faraday Mill
Cattledown
Plymouth
IPSWICH
(M48)
Unit 6C
Elton Park Business
Centre
Hadleigh Road
Ipswich
IP2 0DD
WORCESTER
(M73)
Unit 1&2
PL4 0ST
Northbrook Close
Gregorys Mill Ind
Estate
REDRUTH
(M36)
Unit 7D Pool Industrial
Estate
Wilson Way, Redruth,
Cornwall
TR15 3QW
Worcester
WR3 8BP
NORWICH
(M52)
2b Trafalgar Street
Norwich
NR1 3HN
SUNBURY
(M63)
Unit 1a
The Summit
Hanworth Road
Hanworth Ind Estate
Sunbury on Thames
TW16 5D
8
Instructions for the Installer
Engineers technical data
OVERALL DIMENSIONS
SUPPLY CONNECTIONS
Gas:
Width:
Depth:
Height:
580 mm.
500 mm.
8 mm.
RC 1/2 inch (1/2 inch male) Rear right hand corner
Electric:
230-240V 50Hz supply, 3 core flexible cable with non
rewireable plug fitted with a 3 amp cartridge fuse.
CUT OUT DIMENSIONS
Width:
Depth:
550 mm.
470 mm.
Thickness: 30 mm.
Ignition HT Spark
Spark Generator Ispra Control's BF 50066 - 230-240V 0.6 YA T 120
Spark Gap Fixed
Rear Left Burner (semi-rapid)
Rear Right Burner (semi-rapid)
Heat Input 2.0 kW (6824 BTU/HR)
Heat Input 2.0 kW (6824 BTU/HR)
Front Left Burner (rapid)
Front Right Burner (auxiliary)
Heat Input 3.0 kW (10236 BTU/HR)
Heat Input 1.0 kW (3412 BTU/HR)
BURNER
RAPID
(large)
SEMI-RAPID
(medium)
AUXILIARY
(small)
Characteristics
POSITION
MAX
MIN
MAX
MIN
MAX
MIN
NOMINAL THERMAL
POWER
NOMINAL FLOW
RATE
kW
3.0
0.65
2.0
0.190
9 6
0.45
0.043
Adjust.
1.0
0.095
7 0
0.33
0.031
Adjust.
m3/h 0.286 0.062
NOZZLE REFERENCE
1/100 mm
119
2.8
Adjust.
0.65
NOMINAL THERMAL
POWER
kW
2.0
0.45
1.0
0.33
NOMINAL FLOW
RATE
g/h
202
8 6
4 7
4 0
144
7 1
3 2
3 2
7 2
5 0
2 4
2 8
NOZZLE REFERENCE
1/100 mm
Burner
Dia. Tap By-pass
1/100 mm
APPLIANCE CLASS: 3
APPLIANCE CATEGORY: II2H3+
Auxiliary
Semi-rapid
Rapid
28
32
40
APPLIANCE GAS SUPPLY:
Natural gas G20 / 20mbar
Aerationadjustmentnone
9
Important safety requirements
FITTING THE GAS HOB
WITHOUTACOOKERHOODABOVE
This hob must be installed in accordance with the Gas
Safety (Installation and Use) Regulations (Current Edition)
and the IEE Wiring Regulations (Current Edition).
Detailed recommendations are contained in the following
British Standards Codes Of Practice: B.S. 6172/ B.S.
5440, Part 2 and B.S. 6891 Current Editions.
600 mm
700 mm
The hob should not be installed in a bed sitting room
with a volume of less than 20 m3. If it is installed in a
room of volume less than 5 m3 an air vent of effective
area of 110 cm2 is required. If it is installed in a room of
volume between 5 m3 and 10 m3 an air vent of effective
area of 50 cm2 is required, while if the volume exceeds
11 m3 no air vent is required.
400 mm
55 mm
400 mm
50 mm
100 mm
50 mm
However, if the room has a door which opens directly to
the outside no air vent is required even if the volume is
between 5 m3 and 11 m3.
If there are other fuel burning appliances in the same
room, B.S. 5440 Part 2 Current Edition, should be
consulted to determine the requisite air vent requirements.
FO 2369*
FITTING THE GAS HOB
WITHACOOKERHOODABOVE
600 mm
Location
The hob may be located in a kitchen, a kitchen/diner or
bed sitting room, but not in a bathroom or shower room.
Before making the cut out in the worktop ensure that the
edges of the hob that are to be near either a side or rear
wall have a minimum distance of 55 mm. between the
edge of the hob and the wall.
The minimum distance combustible material can be fitted
above the hob is 400 mm. If it is fitted below 400 mm. a
space of 50 mm. must be allowed from the edges of the
hob.
700 mm
400 mm
55 mm
400 mm
50 mm
100 mm
50 mm
The minimum distance combustible material can be fitted
directly above the hob is 700 mm.
A minimum distance of 100 mm. must be left between
the side edges of the hob and any adjacent cabinets or
walls.
FO 2231*
Installation
IMPORTANT
WHEN THE HOB IS FIRST INSTALLED
This hob must be installed by qualified
personnel to the relevant British Standards.
Once the hob has been installed, it is important
to remove any protective materials, which were
put on in the factory.
Any gas installation must be carried out by a
registered CORGI installer.
On the end of the shaft, which includes the GJ 1/2"
threaded elbow, adjustment is fixed so that the washer
is fitted between the components as shown in the
diagram. Screw the parts together without using excessive
force.
The manufacturer will not accept liability, should
the above instructions or any of the other safety
instructions incorporated in this book be
ignored.
10
Gas Connection
Connection to the gas supply should be with either rigid
or semi-rigid pipe, i.e. steel or copper.
The connection should be suitable for connecting to RC
1/2 (1/2 BSP male thread).
When the final connection has been made, it is essential
that a thorough leak test is carried out on the hob and
installation.
Ensure that the main connection pipe does not exert
any strain on the hob.
A) End of shaft with nut
B) Washer
C) Elbow
FO 0264
Rectangular cut-out size for hob
It is important to install the elbow correctly, with
the shoulder on the end of the thread, fitted to the
hob connecting pipe.
Failure to ensure the correct assembly will cause
leakage of gas.
55 min.
Cut Out Size
The dimensions of the cut-out are given in the diagram.
470
550
Dimensions are given in mm.
FO 2098
1
ON/OFF SWITCH
Building In
Building over a cupboard or
drawer
FLEX
OUTLET
If the hob is to be installed above a cupboard or drawer
it will be necessary to fit a heat resistant board below
the base of the hob on the underside of the work
surface.
It is also recommended to carry out the electrical
connection to the hob as shown in diagrams 1 and 2.
FO 0763
Building over a kitchen unit
with door
ON/OFF SWITCH
3
2
Proper arrangements must be taken in designing the
furniture unit, in order to avoid any contact with the
bottom of the hob which can be heated when it is
operated. The recommended solution is shown in
diagram 3.
The panel fitted under the hob ("a") should be easily
removable to allow easy access if technical
assistance is needed. The space behind the kitchen
unit ("b") can be used for connections.
a
60
b
FLEX
OUTLET
FO 1013
FO 0764
Dimensions are given in mm.
11
Fitting the Hob into the worktop
Carry out the building in of the hob as follows:
put the seals supplied with the hob, on the
edges of the cut out: place them exactly on
the front and rear edge and at 50 mm. from the
side edges, taking care that the seals meet
without overlapping;
F
Seal
a
place the hob in the cut out, taking care that it
is centred;
fix the hob with the relevant fixing clamps and
screws, as shown in the diagram. When the
screws have been tightened, the excess seal
can be removed.
FO 0199
The edge of the hob forms a double seal which prevents
the ingress of liquids.
Electrical connections
Any electrical work required to install this hob
should be carried out by a qualified electrician or
competent person, in accordance with the current
regulations.
Upon completion there must be no cut, or stray strands
of wire present and the cord clamp must be secure over
the outer sheath.
A cut off plug inserted into a 13 amp socket is a
seriuos safety (shock) hazard. Ensure that the cut
off plug is disposed of safely.
THIS HOB MUST BE EARTHED.
The manufacturer declines any liability should these
safety measures not be observed.
This hob is designed to be connected to a 230-240V
50Hz AC electrical supply.
Permanent Connection
In the case of a permanent connection, it is necessary
that you install a double pole switch between the hob
and the electricity supply (mains), with a minimum gap
of 3 mm. between the switch contacts and of a type
suitable for the required load in compliance with the current
electric regulations.
Before switching on, make sure the electricity supply
voltage is the same as that indicated on the hob rating
plate. The rating plate is located on the bottom of the
hob. A copy is attached on the back cover of this book.
The hob is supplied with a 3 core flexible supply cord
incorporating a 3amp plug fitted. In the event of having to
change the fuse, a 3ampASTAapproved (BS 1362) fuse
must be used.
The switch must not break the yellow and green earth
cable at any point.
Ensure that the hob supply cord does not
come into contact with surfaces with
temperatures higher than 50 deg. C.
Should the plug need to be replaced for any reason, the
wires in the mains lead are coloured in accordance with
the following code:
Green and Yellow - Earth
Blue
- Neutral
- Live
Brown
Connect the green and yellow (earth) wire to
the terminal in the plug which is marked with
F
the letter 'E' or the earth symbol
green and yellow.
or coloured
Connect the blue (neutral) wire to the terminal
in the plug which is marked with the letter 'N' or
coloured black.
Connect the brown (live) wire to the terminal in
the plug which is marked with the letter 'L' or
coloured red.
FO 0390
12
Wiring Diagram
L
1
A
2
3
4
5
6
0
220/240
A. IGNITOR SWITCH
B. IGNITOR UNIT
B
N
Fault Finding
Preliminary Electrical Systems
Check
SOCKET
(face view)
PLUG (with cover
removed)
( )
Earth Wire
Green/Yellow
( )
E
Blue
Brown
Green
Yellow
START
Isolate appliance
and carry out:
A: Earth Continuity
check.
Neutral Wire
Blue
N
L
Blue
Green
Yellow
Brown
Carry out:
D: Resistance to
Earth check.
Electricity supply
should now be
satisfactory.
NO
YES
Carry out:
C: Polarity check.
Has inlet fuse blown?
A. EARTH CONTINUITY CHECK -Appliance must be
electrically disconnected - meter set on W (Ohms) x
1 scale and adjust zero if necessary.
NO
YES
a) Testleadsfromanyapplianceearthpointtoearth
pin on plug. Resistance should be less than 0.1
ý (Ohm), check all earth wires for continuity and
all contacts are clean and tight.
Inlet wiring
faulty.
B. INSULATION CHECK - Appliance electrically
Rectify any
fault.
disconnected, all switches ON.
a) meter set on W(Ohms) x 1 scale.
TestleadsfromLtoNinapplianceterminalblock.
If meter reads «0» then there is a short circuit.
b) meter set on W (Ohm) x 100 scale.
Repeat test with leads from L to E. If meter reads
less than × (infinity) there is a fault.
Isolate appliance and
carry out:
B: Insulation check.
Rectify any fault
including replacing
fuses as necessary.
NOTE - Should it be found that the fuse has failed
but no fault is indicated - a detailed continuity check
(i.e. by disconnecting and checking each
component) is required to trace the faulty component.
It is possible that a fault could occur as a result of
local burning/arcing but no fault could be found under
test. However a detailed visual inspection should
reveal evidence of burning around the fault.
13
Ignition System / Gas Ignition
YES
Check gas supply at
burner
Ignitor does not spark
NO
Check plug top fuse
and replace if
necessary
Light burner manually
Check polarity and
earth continuity of
supply point
Check by pass simmer
adjusted
Check position of the
electrode
Check earth continuity
of appliance
Check continuity from the tip of
each electrode to the
terminals 1 to 4 on the ignitor
unit
Check fitting of burners
Check continuity from 'N' on the
mains connector block and "O" on
the ignitor unit
Check continuity from 'L' on the
mains connector block and the
taps ignition switches
Check for breaks in the
insulation
of the HT leads
Check continuity from ignition
switches connector to ignitor unit
Change the taps
ignition switches
Change the ignitor unit
14
Commissioning
When the hob has been fully installed it will be necessary
to check the minimum flame setting. To do this, follow
the procedure below.
-
-
Turn the gas tap to the MAX position and ignite.
Set the gas tap to the MIN flame position then turn
the control knob from MIN to MAX several times. If
the flame is unstable or is extinguished follow the
procedure below.
Procedure:
Re-ignite the burner and set to MIN.
Minimum adjustment screw
FRemove the control knob.
To adjust, use a thin bladed screwdriver and turn
the adjustment screw (see diagram) until the flame
is steady and does not extinguish, when the knob
is turned from MIN to MAX. Repeat this procedure
for all burners.
Pressure Testing
Remove left hand pan support and front left burner
Fcap and crown.
Fit manometer tube over the injector.
Turn on the burner gas supply and ignite another
burner.
The pressure reading should be nominally 20mbar
and must be between 17 mbar and 25mbar.
Turn off the burner supplies.
Conversion from Natural Gas to
LPG
It is important to note that this model is designed for use
TO ADJUST THE GAS RATE
with natural gas but can be converted for use with butane
or propane gas providing the correct injectors are fitted.
With the aid of a thin bladed screwdriver completely
The gas rate is adjusted to suit.
tighten down the by pass adjustment screw, which is
located down the centre of the gas tap control shaft.
Upon completion stick the replacement rating plate on
the under side of the hob.
Method
Ensure that the gas taps are in the 'OFF' position
Isolate the hob from the electrical supply
Remove all pan supports, burner caps, rings, crowns
and control knobs.
With the aid of a 7mm box spanner the burner injectors
can then be unscrewed and replaced by the
appropriate LPG injectors.
IMPORTANT
The replacement/conversion of the gas hob
should only be undertaken by a competent
person.
15
CUSTOMER CARE
55-77 High Street
Slough
Berkshire, SL1 1DZ
Tel: 08705-950950
© Electrolux HouseholdAppliances Limited 2000
|