Electrolux Icon E36GC70ISS User Manual

Induction Cooktop  
E30IC80ISS  
30" INDUCTION COOKTOP  
Configuration  
4 Induction Elements  
FEATURES  
Black Vitroceramic Glass Surface  
10" Element – 2500W/3800W  
8" Element – 2400W/3400W  
7" Element – 1900W/2600W  
6" Element – 1500W/1900W  
Precision Touch Controls  
A.D.A. Compliant*  
Yes  
1
1
1
1
Yes  
Yes  
ACCESSORIES  
Granite Countertop Installation Kit – PN# 903061-9010  
Optional  
SPECIFICATIONS  
Overall Exterior Dimensions –  
Yes  
Height  
4-3/8"  
Width  
30-3/4"  
Depth  
21-1/2"  
Power Supply Location  
Amps@240/208 Volts  
Middle Right Rear  
32.0/32.0  
7.7/6.7  
Connected Load (kW Rating) @ 240/208 Volts  
Electrical – Single phase 3- or 4-wire cable, 120/240V or  
120/208V, 60Hz, fused on both sides of line with ground.  
Required  
Armored Electrical Cable  
Included  
Yes  
Approved for Single Oven Combination Installation**  
Approved for Downdraft Vent Combination Installation**  
Shipping Weight (Approx.)  
Yes  
58 Lbs.  
*When properly installed, meets the appliance standards in the Americans with Disabilities  
Act and the Architectural Barriers Act Accessibility Guidelines as published by the United  
States Access Board on June 23, 2004, as amended August 5, 2005.  
**Approved to be used over any Electrolux ICON® Single Wall Oven and in combination  
with an Electrolux ICON® Downdraft Vent.  
More Responsive  
NOTE: Always consult local and national electric codes. Refer to Product Installation  
Guide for detailed installation instructions on the web at electroluxicon.com.  
Cooking with induction is more responsive  
than gas or electric — you can instantly adjust  
the heat to a delicate simmer or bring it to a  
quick boil.  
Specifications subject to change.  
Powerful Cooking Elements  
Four induction elements, including a 10"  
(2500W/3800W), an 8" (2400W/3400W), a  
7" (1900W/2600W) and a 6" (1500W/1900W)  
combine to create remarkably adaptable  
cooking areas.  
Precision Touch Controls  
Fifteen preset touch settings provide a level of  
digital heat control that inspires confidence in  
even the most particular chef.  
Power Assist  
Generates rapid heat for a quick boil.  
electroluxicon.com  
Electric Cooktop Installation  
Over 30"Electric Single Wall Oven  
For all approved electric cooktop models, cut minimum  
4" x 4" opening in right cabinet side panel and/or filler  
panel, to route armoured cable to junction box  
Side filler panels necessary to isolate oven from  
adjoining cabinets. Panel height may need to  
be modified to accommodate the depth of approved  
electric cooktop models  
240/208V  
Junction box  
for electric  
cooktop  
Electric Single Wall Oven Cutout  
For models: E30EW75GPS  
& E30EW75GSS  
Cooktop  
cutout**  
Approx. 3"  
Oven cutout  
36"  
min.  
Approx. 3"  
28 1/2" min.  
28 7/8" max.  
24"min.*  
240/208V  
Junction box  
for wall oven  
281/2"min.  
29"max.  
Install 3/4" full plywood base on 2 runners, flush  
with toe plate, capable of supporting 200 lbs.  
24" min.  
cutout depth  
Unit will overlap cutout (minimum) edges by 1"  
To route armored cable to junction box through left cabinet side panel  
and/or filler panel, cut minimum 4" x 4" opening in wood base and runner  
4-1/2" maximum height allowed  
from oven base to floor if cooktop  
is installed directly over wall oven.  
(5" maximum height allowed  
with no cooktop.)  
*Critical dimension – MUST be applied  
**For cooktop cutout dimensions refer to model-specific  
product page or installation guide on web  
30" Electric Single Wall Oven Under-Counter  
Installation Specifications  
Electric Cooktop Installation Over  
30" Electric Single Wall Oven Specifications  
®
Product Weights – (E30EW75GPS) 178 Lbs. / (E30EW75GSS) 175 Lbs.  
Electrolux ICON Single Wall Oven models E30EW75GPS and  
E30EW75GSS are approved to be used beneath Electrolux ICON  
electric cooktop models E36IC75FSS, E30IC75FSS, E36IC80ISS,  
E30IC80ISS, E36EC70FSS and E30EC70FSS (electric cooktop  
®
Single phase 3- or 4-wire cable, 120/240 or 120/208 Volt, 60 Hertz  
AC only electrical supply with ground required on separate circuit fused  
on both sides of line.  
Connected Load (kW Rating) @ 240/208 Volts = 4.0/3.0kW  
Amps @ 240/208 Volts =16.6/14.4 Amps  
Always consult local and national electric codes.  
Minimum 23-1/4" clearance for oven door depth when open.  
models NOT approved for use in this installation are E36EC75HSS,  
E30EC65ESS and E36EC65ESS).  
For detailed Electric Cooktop installation, refer to model-specific product  
page and installation guide on web.  
Side filler panels necessary to isolate oven from adjoining cabinets.  
Minimum 24" deep cutout dimension is critical for proper installation,  
to ensure that ovens faceplate will fit flush against cabinet front.  
Panel height may need to be modified to accommodate the depth of  
approved electric cooktop models.  
Full oven base of solid plywood or similar material required, capable  
of supporting 200 Lbs. Install over two runners and flush with toe plate.  
Base must be level and cabinet front must be square with finish-cut  
bottom edge.  
To route armored cable to junction box, cut minimum 4" x 4" opening  
in right cabinet side panel.  
Allow 4-1/2" maximum height from oven base to floor, if cooktop is  
installed directly over wall oven.  
Side filler panels necessary to isolate oven from adjoining cabinets.  
Allow 5" maximum height from oven base to floor, if NO cooktop is  
installed directly over wall oven.  
Note: For planning purposes only. Refer to Product Installation Guide  
on the web at electroluxicon.com for detailed instructions.  
Electrolux Major Appliances, N.A.  
High standards of quality at Electrolux Home Products, Inc. mean we are  
constantly working to improve our products. We reserve the right to change  
specifications or discontinue models without notice.  
USA 250 Bobby Jones Expressway Augusta, GA 30907 1-877-4electrolux (1-877-435-3287) electroluxicon.com  
CANADA 5855 Terry Fox Way Mississauga, ON L5V 3E4 1-800-265-8352 electroluxicon.ca  
EC_EW INST 05/09 © 2009 Electrolux Home Products, Inc.  
Printed in the U.S.A.  
Drop-In Cooktop/Downdraft Vent  
Countertop Preparation  
Countertop Preparation for 30" & 36" Drop-In Cooktop/Downdraft Vent Installation  
Vertical noncombustible surface - rear wall  
B
Backsplash  
Top  
3
/
4"max.  
For detailed cooktop and  
downdraft vent installation  
specifications, refer to  
model-specific product  
page and installation  
guide on web  
29/16"  
231/4  
min.  
"
D*  
1
/
4"min.  
flat ledge  
C
Flush with  
back side of  
cabinet front  
E**  
* Overall flat ledge behind  
backside of cabinet front  
25"  
** Minimum flat surface required  
to fit top surface of cooktop  
and downdraft vent cap  
A
E30DD75ESS/30" Cooktop Cutout Dimensions  
30" Cooktops  
E36DD75ESS/36" Cooktop Cutout Dimensions  
A
B
C
D
E
36" Cooktops  
E36EC65ESS  
E36EC70FSS  
E36GC65ESS  
E36GC70ISS  
E36IC80ISS  
A
B
C
D
E
E30EC65ESS  
E30EC70FSS  
E30GC64ESS  
E30GC70ISS  
E30IC80ISS  
30" 273/4  
30" 273/4  
271/2 273/4  
281/2 273/4  
293/4 273/4  
"
"
"
"
20 3/8  
20 1/4  
19 7/8  
19 3/4  
201/2  
"
"
"
"
23 3/16" 24 3/16"  
231/16" 241/16"  
2211/16" 2311/16"  
22 9/16" 23 9/16"  
23 5/16" 24 5/16"  
36" 33 3/4  
36" 33 3/4  
33 3/4 33 3/4  
341/2 33 3/4  
36" 33 3/4  
"
"
"
"
20 3/8  
201/2  
19 7/8  
19 3/4  
201/2  
"
"
"
"
23 3/16" 24 3/16"  
235/16" 245/16"  
2211/16" 2311/16"  
22 9/16" 23 9/16"  
23 5/16" 24 5/16"  
"
"
"
"
"
"
"
"
"
25"(standard countertop)*  
4"max. backsplash thickness  
Countertop  
backsplash  
3
Cooktop Installation Note:  
/
To ensure proper installation, refer to model-specific installation  
guide on web for cooktop dimensions, cutout dimensions and  
cabinet requirements. Due to varying cooktop depths, tight fit  
is possible between cooktop and vent.  
1
/4"min. flat ledge  
213/16"  
21/8  
Countertop  
raised lip  
Downdraft  
chimney top  
"
Studwall  
Countertop Preparation Note:  
Be aware of areas of potential interference called out in  
illustration. Countertop with raised lip and/or backsplash may  
not allow enough flat area for proper installation, 2-13/16"  
of flat countertop required behind cooktop. No gap required  
between back of cooktop and front of downdraft trim piece.  
3"  
9/32"  
Cooktop  
115/16"  
Vent unit  
Back side of  
cabinet front  
Vertical noncombustible surface - rear wall  
231/4"min.  
213/16"  
*Standard 25" countertop depth may NOT be adequate for  
some cooktop/vent installations, especially with backsplash.  
Stiffener  
Drop-In Cooktop/Downdraft Vent  
Countertop Preparation Specifications  
For detailed Drop-In Cooktop installation, refer to model-specific product  
Amps @120 Volts = 8.0 Amps  
Vent unit outside of building only.  
Vent must be installed in vertical orientation only.  
1,600 CFM remote exhaust blower (PN# 5304444802)  
included with vent – shipped in separate box.  
Do not use flexible duct. Round duct instead of rectangular duct  
recommended, especially when elbows are required.  
When multiple elbows are necessary, ensure a minimum of 24" of  
straight duct between any two elbows.  
Thermal breaks such as short section of nonmetallic duct, should  
be used in areas of extreme cold.  
For most efficient airflow exhaust, use a straight run or as few elbows  
as possible.  
Cold weather installations should have additional backdraft damper  
installed.  
page and installation guide on web. Plan installation so that all required  
minimum clearances between cooktop, overhead cabinets and adjacent  
vertical walls are provided.  
Position cooktop/vent cutout so all required minimum clearances are met.  
Minimum flat countertop area must meet or exceed combined overall  
width and depth as shown. Standard 25" countertop depth may NOT be  
adequate for some cooktop/vent installations, especially with backsplash.  
Separate circuits required for cooktop and vent. (Refer to product-specific  
electrical specifications.)  
Always consult local and national electric and gas codes. Check local  
building codes for installation requirements, as they may vary per locale.  
Downdraft Vent Specifications  
For detailed Downdraft Vent installations, refer to model-specific  
product page and installation guide on web.  
Voltage Rating 120V/ 60Hz/15 Amps  
Connected Load (kW Rating) @120 Volts = 1.0kW  
(For use on adequately wired 120V, dedicated circuit having 2-wire  
service with a separate ground wire. Appliance must be grounded  
for safe operation.)  
Installing a Downdraft Vent in combination with any gas cooking  
surface will affect optimum burner efficiency.  
Note: For planning purposes only. Refer to Product Installation Guide  
on the web at electroluxicon.com for detailed instructions.  
Electrolux Major Appliances, N.A.  
High standards of quality at Electrolux Home Products, Inc. mean we are  
constantly working to improve our products. We reserve the right to change  
specifications or discontinue models without notice.  
USA 250 Bobby Jones Expressway Augusta, GA 30907 1-877-4electrolux (1-877-435-3287) electroluxicon.com  
CANADA 5855 Terry Fox Way Mississauga, ON L5V 3E4 1-800-265-8352 electroluxicon.ca  
DIC_DDV_PREP 05/09 © 2009 Electrolux Home Products, Inc.  
Printed in the U.S.A.  

Hanns G HL221 User Manual
Fujitsu Computer Monitor 154V User Manual
Freecom Technologies DVD RW Recorder User Manual
Elo TouchSystems 1827L Series User Manual
Electrolux SIG 400 User Manual
DoubleSight Displays DoubleSight DS 1700S User Manual
Dacor Convection Oven MRWD30 User Manual
Black Box Computer Hardware LMC5116C R3 User Manual
A T International CL83201 User Manual
Acer Computer Monitor V223PWL User Manual