Designed for the well-lived home.
Gas Slide-In Cooktop
E30GC74GPS
30" GAS SLIDE-IN COOKTOP
Configuration
4 Sealed Burners
FEATURES
Formed Stainless Steel Platform
Large Professional Skirted Knobs with Bezel
Min-2-Max™ Dual-Ring Sealed Burner (BTU)
Sealed Power Burner™ (BTU)
Sealed Precision Burner™ (BTU)
Linear Flow Burner Valves
Yes
4
2 (18,000 – 450)
1 (14,000)
1 (5,000)
4
Electronic Ignition with Auto Re-Ignition
Continuous Grates
Yes
3
ACCESSORIES
Griddle
Included
Included
Included
Optional
Optional
Optional
Wok Ring
Simmer Plate
9" Stainless Steel Backsplash – 903048-9100
Black Knobs Kit – 903049-9110
Depth Adjustment Filler Kit * – 903051-9100
SPECIFICATIONS
Overall Exterior Dimensions –
Height
7-3/4"
Width
29-7/8"
25"
Depth
Gas Inlet/Power Supply Location
Voltage Rating
Right Rear
120V/60Hz/15A
0.001
‡
Connected Load (kW Rating) @120 Volts
Electrical Cable
Included
No
Approved for Single Oven Combination Installation**
Approved for Downdraft Vent Combination Installation**
Product Weight
Yes
™
Min-2-Max Burners
95 Lbs.
100 Lbs.
Burner configuration includes two versatile
Min-2-Max™ sealed burners delivering anywhere
from 18,000 to 450 BTUs. Thanks to the double
ring configuration, you can simmer sauces or
bring water to a boil. You decide the level of heat
output by a simple turn of the knob.
Shipping Weight (Approx.)
* When replacing an existing cooktop with countertop cutout deeper than 7-1/4"
and less than 8-1/2", order free Depth Adjustment Filler Kit.
‡ For use on adequately wired 120V, dedicated circuit having 2-wire service with
a separate ground wire. Appliance must be grounded for safe operation.
** Not approved to be used over any Electrolux ICON™ Single Wall Oven. Approved to be
used in combination with an Electrolux ICON™ Downdraft Vent. (Proper combination
installation will require cooktop power cord to be relocated.)
NOTE: Always consult local and/or national electric and gas codes. Refer to Product
Installation Guide for detailed installation instructions on the web at electroluxicon.com.
Specifications subject to change.
Four Sealed Burners
Versatile sealed burner configuration provides
the utmost in cooking flexibility. Includes: two
18,000-450 BTU Min-2-Max™ burners, one
14,000 BTU Power Burner™ and one 5,000 BTU
Precision Burner™.
Sealed Cooktop Spill-Basin
Cleanup is convenient with a black porcelain-
coated area beneath the burners to catch spills.
Professional-Style Controls
Large professional-feel, front-mounted control
knobs provide easy and accurate settings. 270
degree rotation offers superior flame control.
Optional black knobs available.
electroluxicon.com
Slide-In Cooktop/Downdraft Vent
Countertop Preparation
Countertop Preparation for 30" & 36" Slide-In Cooktop/Downdraft Vent Installation
For detailed cooktop and downdraft vent
installation specifications, refer to model-specific
product page and installation guide on web
Opening for
downdraft vent
E
71/4
"
7 1/2
"
213/16"
B
C
D
A
1"countertop
overhang
E36DD75ESS/36" Cooktop Cutout Dimensions
36" Cooktops
A
B
C
D
E
E36EC75DSS 3515/16" 35 3/16"
E36EC75ESS 3515/16" 35 3/16"
E36EC75HSS 3515/16" 35 3/16"
E36GC75DSS* 3515/16" 35 3/16"
E36GC75ESS* 3515/16" 35 3/16"
E36GC75GSS* 3515/16" 35 3/16"
E36GC76EPS* 3515/16" 35 3/16"
E36GC76GPS* 3515/16" 35 3/16"
22" 2513/16" 333/4
22" 2513/16" 333/4
22" 2513/16" 333/4
22" 2513/16" 333/4
22" 2513/16" 333/4
22" 2513/16" 333/4
22" 2513/16" 333/4
22" 2513/16" 333/4
"
"
"
"
"
"
"
"
E30DD75ESS/30" Cooktop Cutout Dimensions
30" Cooktop
A
B
C
22"
D
E
E30GC74GPS* 2915/16" 293/16"
25 13/16" 271/2
"
*Proper combination installation will require cooktop power cord
to be relocated to underside of unit. (For details, refer to 30" & 36"
Gas Slide-In Cooktop Power Cord Relocation Instructions page.)
Slide-In Cooktop/Downdraft Vent
Countertop Preparation Specifications
•
•
•
•
Amps @120 Volts = 8.0 Amps
Vent unit outside of building only.
Vent must be installed in vertical orientation only.
1,600 CFM remote exhaust blower (part number 5304444802) included
with vent – shipped in separate box.
Do not use flexible duct. Round duct instead of rectangular duct
recommended, especially when elbows are required.
When multiple elbows are necessary, ensure a minimum of 24" of straight
duct between any two elbows.
Thermal breaks such as short section of nonmetallic duct, should be
used in areas of extreme cold.
For most efficient airflow exhaust, use a straight run or as few elbows
as possible.
Cold weather installations should have additional backdraft damper
installed.
Installing a Downdraft Vent in combination with any gas cooking surface
will affect optimum burner efficiency.
•
For detailed Slide-In Cooktop installation, refer to model-specific product
page and installation guide on web. Plan installation so that all required
minimum clearances between cooktop, overhead cabinets and adjacent
vertical walls are provided.
•
Position cooktop/vent cutout so all required minimum clearances
are met.
•
•
•
•
•
•
•
•
Minimum flat countertop area must meet or exceed combined overall
width and depth as shown.
•
Separate circuits required for cooktop and vent. (Refer to product-specific
electrical specifications.)
•
Always consult local and/or national electric codes. Check local building
codes for installation requirements, as they may vary per locale.
•
Proper combination installation will require 30" & 36" Gas Slide-In
Cooktop power cord to be relocated to underside of unit. (For details,
refer to 30" & 36" Gas Slide-In Cooktop Power Cord Relocation
Instructions on web.)
Downdraft Vent Specifications
Downdraft Vents can NOT be used in combination with any cooktop
backsplash.
•
For detailed Downdraft Vent installations, refer to model-specific
product page and installation guide on web.
Note: For planning purposes only. Refer to Product Installation Guide
on the web at electroluxicon.com for detailed instructions.
•
Voltage Rating –120V/ 60Hz/15 Amps
•
Connected Load (kW Rating) @120 Volts = 1.0kW
(For use on adequately wired 120V, dedicated circuit having 2-wire
service with a separate ground wire. Appliance must be grounded for
safe operation.)
High standards of quality at Electrolux Home Products, Inc. mean we are
constantly working to improve our products. We reserve the right to change
specifications or discontinue models without notice.
•
•
•
•
USA 250 Bobby Jones Expressway Augusta, GA 30907 1-877-4electrolux (1-877-435-3287) electroluxicon.com
•
•
•
•
CANADA 5855 Terry Fox Way Mississauga, ON L5V 3E4 1-800-265-8352 electroluxicon.ca
SIC_DDV_PREP 05/08 © 2008 Electrolux Home Products, Inc.
Printed in the U.S.A.
30" & 36" Gas Slide-In Cooktop
Power Cord Relocation Instructions
1
4
7
2
5
8
3
6
9
To install an Electrolux ICON™ Gas Slide-In Cooktop in combination with an
Electrolux ICON™ Downdraft Vent, cooktop power cord MUST be relocated to underside of unit.
10
Gas Slide-In Cooktops requiring this procedure are: E30GC74GPS, E36GC75DSS, E36GC75ESS,
E36GC75GSS, E36GC76EPS and E36GC76GPS.
Please have qualified electrician perform following rewiring procedure in accordance with local and
national electric codes.
Tools & Materials:
Phillips-Head Screwdriver, Hammer, Awl or Punch, Drill with 3/4" drill bit,
2-Plastic Inserts (73209-2470), Silicone Caulk and Aluminum Tape.
Procedure:
6. Place plastic inserts in upper and lower
1. Remove electrical access panel from rear
drilled holes to protect cord.
of cooktop.
11
7. Knot power cord to secure into place.
8. Reconnect power cord and ground wires.
2. Disconnect power cord and ground wires,
then remove from cooktop.
3. Locate area for new hole to be drilled, 1/2"
in from back edge on underside of cooktop,
then mark hole location using an awl or punch.
9. Fill remaining hole surrounding power cord
with silicone caulk.
10. Cover both sides of original hole with two
4. Use 3/4" drill bit to drill new hole completely
layers of aluminum tape.
through.
11. Screw electrical access panel back in place.
5. Route power cord wires through hole.
High standards of quality at Electrolux Home Products, Inc. mean we are
constantly working to improve our products. We reserve the right to change
specifications or discontinue models without notice.
•
•
•
•
USA 250 Bobby Jones Expressway Augusta, GA 30907 1-877-4electrolux (1-877-435-3287) electroluxicon.com
•
•
•
•
CANADA 5855 Terry Fox Way Mississauga, ON L5V 3E4 1-800-265-8352 electroluxicon.ca
GC_PCRELO 03/08 © 2008 Electrolux Home Products, Inc.
Printed in the U.S.A.
|