Induction Cooktop
E36IC80ISS
36" INDUCTION COOKTOP
Configuration
5 Induction Elements
FEATURES
Black Vitroceramic Glass Surface
10" Element – 2500W/3800W
8" Element – 2400W/3400W
7" Element – 1900W/2600W
6" Element – 1500W/1900W
Custom-Set™ Controls
Yes
2
1
1
1
Yes
Yes
Yes
Keep Warm Setting
A.D.A. Compliant*
ACCESSORIES
Granite Countertop Installation Kit – PN# 903061-9010
Optional
SPECIFICATIONS
Product Dimensions –
Width
36-3/4"
Depth
21-1/2"
Height
4-3/8"
Power Supply Location
Amps@240/208 Volts
Middle Rear
46.0/46.0
11.1/9.6
Connected Load (kW Rating) @ 240/208 Volts
Electrical – Single phase 3- or 4-wire cable, 120/240V or
120/208V, 60Hz, fused on both sides of line with ground.
Required
Armored Electrical Cable
Included
Yes
Approved for Single Oven Combination Installation**
Approved for Downdraft Vent Combination Installation**
Shipping Weight (Approx.)
Yes
73 Lbs.
*When properly installed, meets the appliance standards in the Americans with Disabilities
Act and the Architectural Barriers Act Accessibility Guidelines as published by the United
States Access Board on June 23, 2004, as amended August 5, 2005.
Boil Water Quickly
**Approved to be used over any Electrolux ICON® Single Wall Oven and in combination
with an Electrolux ICON® Downdraft Vent.
Induction technology is more responsive than
gas or electric, and the Power Assist™ function
generates rapid heat, so you can bring water
to a boil quickly.
NOTE: Always consult local and national electric codes. Refer to Product Installation
Guide for detailed installation instructions on the web at electroluxicon.com.
Specifications subject to change.
Exceptional Temperature Control
Adjust heat with greater precision than on gas
or electric cooktops, especially at lower settings.
Ideal for melting chocolate and cooking delicate
foods and sauces.
More Responsive
Cooking with induction is more responsive than
gas or electric —you can instantly take the heat
from boil to simmer.
More Energy-Efficient
Cooking with induction is 70% more efficient
than gas and 20% more efficient than electric.
electroluxicon.com
Drop-In Cooktop/Downdraft Vent
Countertop Preparation
Countertop Preparation for 30" & 36" Drop-In Cooktop/Downdraft Vent Installation
Vertical noncombustible surface - rear wall
B
Backsplash
Top
3
/
4"max.
For detailed cooktop and
downdraft vent installation
specifications, refer to
model-specific product
page and installation
guide on web
29/16"
231/4
min.
"
D*
1
/
4"min.
flat ledge
C
Flush with
back side of
cabinet front
E**
* Overall flat ledge behind
backside of cabinet front
25"
** Minimum flat surface required
to fit top surface of cooktop
and downdraft vent cap
A
E30DD75ESS/30" Cooktop Cutout Dimensions
30" Cooktops
E36DD75ESS/36" Cooktop Cutout Dimensions
A
B
C
D
E
36" Cooktops
E36EC65ESS
E36EC70FSS
E36GC65ESS
E36GC70FSS
E36IC80ISS
A
B
C
D
E
E30EC65ESS
E30EC70FSS
E30GC64ESS
E30GC70FSS
E30IC80ISS
30" 273/4
30" 273/4
271/2 273/4
281/2 273/4
293/4 273/4
"
"
"
"
20 3/8
20 1/4
19 7/8
19 3/4
201/2
"
"
"
"
23 3/16" 24 3/16"
231/16" 241/16"
2211/16" 2311/16"
22 9/16" 23 9/16"
23 5/16" 24 5/16"
36" 33 3/4
36" 33 3/4
33 3/4 33 3/4
341/2 33 3/4
36" 33 3/4
"
"
"
"
20 3/8
201/2
19 7/8
19 3/4
201/2
"
"
"
"
23 3/16" 24 3/16"
235/16" 245/16"
2211/16" 2311/16"
22 9/16" 23 9/16"
23 5/16" 24 5/16"
"
"
"
"
"
"
"
"
"
25"(standard countertop)*
4"max. backsplash thickness
Countertop
backsplash
3
Cooktop Installation Note:
/
To ensure proper installation, refer to model-specific installation
guide on web for cooktop dimensions, cutout dimensions and
cabinet requirements. Due to varying cooktop depths, tight fit
is possible between cooktop and vent.
1
/4"min. flat ledge
213/16"
21/8
Countertop
raised lip
Downdraft
chimney top
"
Studwall
Countertop Preparation Note:
Be aware of areas of potential interference called out in
illustration. Countertop with raised lip and/or backsplash may
not allow enough flat area for proper installation, 2-13/16"
of flat countertop required behind cooktop. No gap required
between back of cooktop and front of downdraft trim piece.
3"
9/32"
Cooktop
115/16"
Vent unit
Back side of
cabinet front
Vertical noncombustible surface - rear wall
231/4"min.
213/16"
*Standard 25" countertop depth may NOT be adequate for
some cooktop/vent installations, especially with backsplash.
Stiffener
Drop-In Cooktop/Downdraft Vent
Countertop Preparation Specifications
•
•
For detailed Drop-In Cooktop installation, refer to model-specific product
Amps @120 Volts = 8.0 Amps
Vent unit outside of building only.
Vent must be installed in vertical orientation only.
1,600 CFM remote exhaust blower (PN# 5304444802)
included with vent – shipped in separate box.
Do not use flexible duct. Round duct instead of rectangular duct
recommended, especially when elbows are required.
When multiple elbows are necessary, ensure a minimum of 24" of
straight duct between any two elbows.
Thermal breaks such as short section of nonmetallic duct, should
be used in areas of extreme cold.
For most efficient airflow exhaust, use a straight run or as few elbows
as possible.
Cold weather installations should have additional backdraft damper
installed.
page and installation guide on web. Plan installation so that all required
minimum clearances between cooktop, overhead cabinets and adjacent
vertical walls are provided.
•
•
•
•
Position cooktop/vent cutout so all required minimum clearances are met.
•
Minimum flat countertop area must meet or exceed combined overall
•
•
•
•
•
•
width and depth as shown. Standard 25" countertop depth may NOT be
adequate for some cooktop/vent installations, especially with backsplash.
•
Separate circuits required for cooktop and vent. (Refer to product-specific
electrical specifications.)
Always consult local and national electric and gas codes. Check local
building codes for installation requirements, as they may vary per locale.
•
Downdraft Vent Specifications
•
For detailed Downdraft Vent installations, refer to model-specific
product page and installation guide on web.
Voltage Rating –120V/ 60Hz/15 Amps
Connected Load (kW Rating) @120 Volts = 1.0kW
(For use on adequately wired 120V, dedicated circuit having 2-wire
service with a separate ground wire. Appliance must be grounded
for safe operation.)
Installing a Downdraft Vent in combination with any gas cooking
surface will affect optimum burner efficiency.
•
•
Note: For planning purposes only. Refer to Product Installation Guide
on the web at electroluxicon.com for detailed instructions.
Electrolux Major Appliances, N.A.
High standards of quality at Electrolux Home Products, Inc. mean we are
constantly working to improve our products. We reserve the right to change
specifications or discontinue models without notice.
•
•
•
•
USA 10200 David Taylor Drive Charlotte, NC 28262 1-877-4electrolux (1-877-435-3287) electroluxicon.com
•
•
•
•
CANADA 5855 Terry Fox Way Mississauga, ON L5V 3E4 1-800-265-8352 electroluxicon.ca
DIC_DDV_PREP 10/10 © 2010 Electrolux Home Products, Inc.
Printed in the U.S.A.
|