COMBINATION INSTALLATIONS  
Document # PGCI-026  
Revised 01/13/12 Page 1/2  
PLANNING  
GUIDE  
DR30DI Range with ERV3015  
Raised Vent  
warning  
Cabinet tolerances: -1/16”, (+1.6 mm) -0  
Observe all governing codes and ordinances during planning  
and installation. Contact your local building department for  
further information.  
All appliances must be installed in accordance with the  
accompanying installation instructions.  
MODEL DR30DI/ERV3015 COUNTERTOP SELf-RIMMED  
ONLy, 3 1/4 INCh SIDE PANELS NOT REMOVED  
Self-rimming installation with raised Vent  
(Option 1)  
Only model DR30DI may be installed with a raised vent. Use only  
Dacor raised vent model ERV3015.  
3/8” min. (1.0 cm)  
10” min.  
(25.4 cm)  
both sides  
Non-combustible  
rear wall recommed  
countertop  
overhang  
A self-rimming countertop configuration is required for raised vent  
installation. On installations with a raised vent, when sliding the range  
into position, it will stop when the rear of the control panel or side  
panels contact the notches toward the front of the countertop.  
2 9/16”  
(6.5 cm)  
9 cm)  
ning  
The self-rimming installation of the DR30DI range and ERV3015  
raised vent create a “built-in” look where the range trim overlaps the  
countertop on both sides and the raised vent overlaps the countertop  
in back. It is also possible, if the cabinets are deep enough, to self  
rim the front of the range into the cabinet face immediately behind the  
control panel and door trim or behind the side panels (see side view
on following page). The rear range trim will partially cover the fron
the raised vent chassis in back.  
m)  
ening  
.2 cm)  
t opening  
w countertop  
A
Combustible side  
wall above range  
B C  
K
J
Notch countertop  
overhang to width of  
cabinets  
Model Dr30Di  
range and ErV3015  
raised Vent with  
a
B
To cabinet face  
below countertop  
To countertop  
front  
TOP VIEw  
Countertop self-  
rimmed only  
20 5/8”  
(52.4 cm)  
0” (0 cm) t
3 1/4” (8.
Countertop height for all self-rimming installatio
35 7/16” (90.0 cm) minimum, 37 7/16” (95.1
3/8” min. (1.0 cm)  
flat countertop  
overhang required  
behind cutout  
Range trim resting  
on countertop  
Cabinet face  
Countertop  
A
Back of  
control  
panel  
DR30DI range  
3 1/4 inch  
side panel  
3/8” min. (1.0 cm) space  
required behind ERV3015  
chassis to clear stiffener  
ERV3015  
raised vent  
SIDE VIEw  
All specifications subject to change without notice.  
Phone: (800) 793-0093  

GE Monogram ZET2S User Manual
Eizo EIZO RadiForce RX211 User Manual
Diamond Multimedia Radeon X550PCIE256 User Manual
DCS RGS 366 User Manual
Cuisinart TOB 60 Series User Manual
COBY electronic CT P9340 User Manual
Cisco Systems Cisco Wave 694 Application Acceleration Appliance WAVE694K9 User Manual
AT T 6200 User Manual
Asko D1776 User Manual
Addonics Technologies DCMR256I User Manual