ER36D, ER48D
PLANNING
GUIDE
®
Epicure Ranges
Revised
03/10/09
1/2
All tolerances: +/- 1/16” (+/- 1.6mm) unless otherwise stated
48” (1219mm)
ELECTRIC CIRCUIT REQUIREMENTS
Total Connected Load
Range Model
ER36D
Circuit Required
240 Vac, 4-wire* 60 Hz,
30 Amp. (Min.) 40 Amp.
(Recommended)
6.5 kW (28 Amp.)
10.0 kW (42 Amp.)
**
240 Vac, 4-wire* 60 Hz,
50 Amp.
**
ER48D
* 4-wire, two 120 Vt (L1 and L2), one neutral, one ground
1 1/16” (27mm) to cooking
surface (top of grates) from
top of trim
**
RE REQUIREMENTS*
Minimum Gas
d Pressure
Finished Side
Panel
Supply Pressure
6” Water Column
11” Water Column
Water Column
10” Water Column
** Optiona
s supply pressure 1/2 p.s.i. for all models
Width: ER36D - 35 7/8” (911mm)
ER48D - 47 7/8” (1216mm)
Gas Regulator Access,
Cover Removed
Range Electrical Access,
Cover Removed
GAS - ELECTRICAL
E*
Model
A
B
5 5/8”
18
3 11/16”
7/8”
Inlet
ER36D
(142.9mm) (466.(347.7mm) (22.2mm)
Back of Range
B
3 13/16” 18 11/16” 13 3/4” 1 1/8”
(96.8mm) (474.7mm) mm) (349.3mm) (28.6mm)
ER48D
D
* The diameter on models equipped for use in Canada is ¼”
(6.4mm) larger than those stated. Canadian units come from
the factory pre-wired with an appliance cord. When installing an
appliance cord on models that are not pre-wired, the hole size must
be increased to 1 1/8” (1 3/8” for model ER48D) by removing the
conduit bracket inside the range electrical access box.
A
E Electrical Connection
Hole in Bottom
C
NOTES:
WARNING
1. When installing a backguard, always install it
before sliding the range into place.
◊
◊
Observe all governing codes and ordinances during
planning and installation. Contact your local building
department for further information.
This appliance must be installed in accordance with the
accompanying installation instructions.
Corporate Phone: 800-793-0093
Specifications are subject to change without notice.
See installation instructions for additional details.