Snapshot
OK on Dimmer
Outdoor OK
Sound Activated
DMX512
Master/Slave
115V/230V Switch
Replaceable Fuse
User Serviceable
Duty Cycle
USER MANUAL
3000 N 29th Ct, Hollywood, FL 33020 U.S.A.
(800) 762-1084 – (954) 929-1115
FAX (954) 929-5560
1. BEFORE YOU BEGIN
What is included
1 x Hurricane™ 1300
1 x FC-T wired timer remote
1 x Warranty Card
1 x User Manual
Unpacking Instructions
Immediately upon receiving a fixture, carefully unpack the carton, check the contents to ensure that
all parts are present, and have been received in good condition. Notify the shipper immediately and
retain packing material for inspection if any parts appear damaged from shipping or the carton itself
shows signs of mishandling. Save the carton and all packing materials. In the event that a fixture
must be returned to the factory, it is important that the fixture be returned in the original factory box
and packing.
AC Power
To determine the power requirements for a particular fixture, see the label affixed to the back plate of
the fixture or refer to the fixture’s specifications chart. A fixture’s listed current rating is its average
current draw under normal conditions. All fixtures must be powered directly off a switched circuit and
cannot be run off a rheostat (variable resistor) or dimmer circuit, even if the rheostat or dimmer
channel is used solely for a 0% to 100% switch. Before applying power to a fixture, check that the
source voltage matches the fixture’s requirement. Check the fixture or device carefully to make sure
that if a voltage selection switch exists that it is set to the correct line voltage you will use.
Hurricane™ 1300 User Manual
3
3/26/2009 3:18 PM
Safety Instructions
Please read these instructions carefully, which includes important
information about the installation, usage and maintenance of this
product.
Please keep this User Guide for future consultation. If you sell the unit to another user, be sure that
they also receive this instruction booklet.
Always make sure that you are connecting to the proper voltage, and that the line voltage you are
connecting to is not higher than that stated on the decal or rear panel of the fixture.
This product is intended for indoor use only! (If applicable)
To prevent risk of fire or shock, do not expose fixture to rain or moisture. Make sure there are no
flammable materials close to the unit while operating.
The unit must be installed in a location with adequate ventilation, at least 20in (50cm) from adjacent
surfaces. Be sure that no ventilation slots are blocked.
Always disconnect from power source before servicing or replacing lamp or fuse and be sure to
replace with same lamp source.
Secure fixture to fastening device using a safety chain. Never carry the fixture solely by its head. Use
its carrying handles.
Maximum ambient temperature (Ta) is 104°F (40°C). Do not operate fixture at temperatures higher
than this.
In the event of a serious operating problem, stop using the unit immediately. Never try to repair the
unit by yourself. Repairs carried out by unskilled people can lead to damage or malfunction. Please
contact the nearest authorized technical assistance center. Always use the same type spare parts.
Never connect the device to a dimmer pack.
Make sure the power cord is never crimped or damaged.
Never disconnect the power cord by pulling or tugging on the cord.
Avoid direct eye exposure to the light source while it is on.
Caution!
There are no user serviceable parts inside the unit. Do not open the housing or
attempt any repairs yourself. In the unlikely event your unit may require service,
please contact CHAUVET at: 954-929-1115.
Hurricane™ 1300 User Manual
4
3/26/2009 3:18 PM
2. INTRODUCTION
Features
Output: 20,000cfm
3.3L tank capacity
Uses 1L every 8min (continuous use at full output)
5 minute heat up
Manual fog button
Low fluid indicator and auto shut down
Wired timer remote included
Water-based fogger
Product Dimensions
Hurricane™ 1300 User Manual
5
3/26/2009 3:18 PM
Product Overview
Hanging
bracket
Safety
eyebolt
Fluid
container
Handle
Tilt
Adjustment
knob
Heater
Nozzle
Low Fluid
indicator
Manual
controller
Fluid level
indicator
Power
switch
Fuse holder
Power input
(hardwired)
Manual Fog
button
Wireless
Controller
Hurricane™ 1300 User Manual
6
3/26/2009 3:18 PM
Disconnect the power cord before replacing a fuse and always
replace with the same type fuse.
Fuse Replacement
With a flat head screwdriver wedge the fuse
holder out of its housing. Remove the damaged
fuse from its holder and replace with exact
same type fuse. Insert the fuse holder back in
its place and reconnect power.
The fuse is located
inside this
compartment.
Remove using a flat
head screwdriver.
Mounting
ORIENTATION
This fixture should only be mounted/used on a flat surface. This fixture may not be tilted.
RIGGING
It is important never to obstruct the vents pathways. Mount the fixture using, a suitable “C” or “O” type
clamp.
When selecting installation location, take into consideration the fluid reservoir access and routine
maintenance.
Safety cables must always be used, utilizing the provided safety eye bolt.
Never mount in places where the fixture will be exposed to rain, high humidity, extreme temperature
changes or restricted ventilation.
Hanging Clamp
Angled Down
Angled Up
Note!
Clamp is sold separately.
Hurricane™ 1300 User Manual
7
3/26/2009 3:18 PM
3. OPERATING INSTRUCTIONS
Operation
Manual Remote Operation (FC-M) (Optional)
1. Plug in the fog machine to power and turn the power switch to the fixture on.
2. Plug in the wired manual remote to the Manual Controller socket on the rear of the fog machine.
3. Press the single button located on the remote to trigger the fog output.
Note: The button is momentary, which means that the fog machine will only output while the
button is pressed. Once the button is released, the fog will stop outputting.
Timer Remote Operation (FC-T) (Standard)
This mode will allow you to control the fogger manually, set the fog machine to run continuously, or to set the fog
machine to run off bursts with adjustable interval and duration settings.
1. Plug in the fog machine to power and turn the power switch to the fixture on.
2. Plug in the timer remote to the Manual Controller socket on the rear of the fog machine.
3. Press the TIMER ON/OFF button on the timer remote. The LED above the button should light, indicating
activation of function.
4. You may now set the INTERVAL & DURATION adjustment knobs to the desired position.
Note: The INTERVAL is the time in between bursts of fog.
Note: The DURATION is the time that the fog machine will run during the burst.
Duration
Interval
Adjustment
Adjustment
Timer LED
Indicator
Manual
Momentary
LED
Manual/Power LED
Indicator
Manual control
momentary button
Timer latching
button
Continuous
latching button
Hurricane™ 1300 User Manual
8
3/26/2009 3:18 PM
Wireless Controller (FC-W) (Optional)
This mode will allow you to control the fogger using the optional wireless controller. This consists of the
transmitter and the receiver. You may control up to 4 independent fog machines or many more if you run them
simultaneously. See the below instructions on setting up your fogger to operate with the FC-W.
1. Plug the wires receiver into the fog machine 5-pin port labeled “Wireless Controller”.
2. There are 4 buttons on the wireless remote transmitter which act as triggers. Each button can be assigned to a
different fog machine. You may only choose 1 dipswitch on each receiver. See the below configuration for
setting the receivers to operate with the transmitter remote.
Mode
Dipswitches
CH1
1 = On, 2-4 = Off
CH2
CH3
CH4
2 = On, 1,3,4 = Off
3 = On, 1,2,4 = Off
4 = On, 1,2,3 = Off
3. Press the fog button, and the fog machine will output fog momentarily for as long as you hold down the button.
LED indicator
LED indicator
(ready)
(heating)
Dipswitches
Wireless
Transmitter
Fog
Triggers
Wireless
Receiver
Hurricane™ 1300 User Manual
9
3/26/2009 3:18 PM
Hurricane™ 1300 General Troubleshooting
Symptom
No Power
Solution(s)
Check mains power.
Check external fuse.
Check internal fuse.
Check fluid level.
No fog output
Check remote.
If using wireless, check batteries.
If using wireless, check dipswitches on receiver.
Possible electrical short. Contact Chauvet or a Chauvet Dealer/distributor for
further instruction.
Breaker/Fuse keeps
blowing
Low fog output
Run a cleaning solution through the fog machine.
Check that the fog machine is plugged into the correct voltage.
Check to replace the external fuse.
Fog machine is not
heating up
Check to replace the internal fuse.
Possible bad part. Contact Chauvet or a Chauvet Dealer/distributor for further
instruction.
Remote does not
work
Make sure connector is firmly connected to device.
Try using another controller. Possible bad controller.
Check the internal fuse.
Check the external fuse.
Fluid indicator states Try resetting the fog machine by turning the power off, and then on again.
no fog, but the
container if full.
Possible bad part. Contact Chauvet or a Chauvet Dealer/distributor for further
instruction.
If you still have a problem after trying the above solutions, please contact CHAUVET Technical
Support at the location listed below.
Contact Us
World Wide
General Information
CHAUVET
3000 North 29th Court
Hollywood, FL 33020
voice: 954.929.1115
fax:
954.929.5560
toll free: 800.762.1084
Technical Support
CHAUVET
3000 North 29th Court
Hollywood, FL 33020
voice: 954.929.1115 (Press 4)
fax:
954.929.5560 (Attention: Service)
World Wide Web
Hurricane™ 1300 User Manual
10
3/26/2009 3:18 PM
4. APPENDIX
General Maintenance
To maintain optimum performance and minimize wear fixtures should be cleaned frequently. Usage
and environment are contributing factors in determining frequency. As a general rule, fixtures should
be cleaned at least twice a month. Dust build up reduces light output performance and can cause
overheating. This can lead to reduced lamp life and increased mechanical wear. Be sure to power off
fixture before conducting maintenance.
Unplug fixture from power. Use a vacuum or air compressor and a soft brush to remove dust
collected on external vents and internal components. Clean all glass when the fixture is cold with a
mild solution of glass cleaner or Isopropyl Alcohol and a soft lint free cotton cloth or lens tissue. Apply
solution to the cloth or tissue and drag dirt and grime to the outside of the lens. Gently polish optical
surfaces until they are free of haze and lint.
The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to
optimize light output. Cleaning frequency depends on the environment in which the fixture operates:
damp, smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit’s
optics. Clean with soft cloth using normal glass cleaning fluid. - Always dry the parts carefully. - Clean
the external optics at least every 20 days. Clean the internal optics at least every 30/60 days.
Returns Procedure
Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued.
Package must be clearly labeled with a Return Merchandise Authorization Number (RMA #).
Products returned without a RMA # will be refused. Call CHAUVET and request a RMA # prior to
shipping the fixture. Be prepared to provide the model number, serial number and a brief description
of the cause for the return. Be sure to properly pack fixture, any shipping damage resulting from
inadequate packaging is the customer’s responsibility. CHAUVET reserves the right to use its own
discretion to repair or replace product(s). As a suggestion, proper UPS packing or double-boxing is
always a safe method to use.
Note:
If you are given a RMA #, please include the following information on a piece of
paper inside the box:
1) Your name
2) Your address
3) Your phone number
4) The RMA #
5) A brief description of the symptoms
Claims
Damage incurred in shipping is the responsibility of the shipper; therefore the damage must be
reported to the carrier upon receipt of merchandise. It is the customer's responsibility to notify and
submit claims with the shipper in the event that a fixture is damaged due to shipping. Any other claim
for items such as missing component/part, damage not related to shipping, and concealed damage,
must be made within seven (7) days of receiving merchandise.
Hurricane™ 1300 User Manual
11
3/26/2009 3:18 PM
Blow-out Diagram.
7
6
2
3
1
4
8
Description
Master PCB
Heater
Part Number
P170-F3MSPCB
P120-HT13
1
2
3
4
5
6
7
8
9
Pump
P200-F3PUMP
P170-F3FLC
Fluid container
Fluid sensor (not shown)
Thermal switch 115° Celsius
Bracket Knob
Fuse holder
Manual fog button
P170-F1FLOS
P170-THEF11
P111-F3BKNOB
P170-FUSEHOL
P111-F3FOGB
P170-FUSE013
10 Fuse 13A 250V (not shown)
11 Fluid filter (not shown)
12 Fluid hose with fittings (not shown)
13 Copper tubing with fittings (not shown)
P110-F1FLAS
P170-F3RUB
P170-F3COP
Hurricane™ 1300 User Manual
12
3/26/2009 3:18 PM
Connections Drawing
In the event that any part(s) may need to be replaced/repaired, you may use the below diagram
to assist in this operation.
Warning: All repairs should only be performed by Authorized Service Personnel.
Hurricane™ 1300 User Manual
13
3/26/2009 3:18 PM
Technical Specifications
WEIGHT & DIMENSIONS
Length .............................................................................................................................. 16.5 in (419 mm)
Width................................................................................................................................ 12.3 in (313 mm)
Height............................................................................................................................... 12.1 in (306 mm)
Weight...................................................................................................................................21 lbs (9.5 kg)
POWER
AC Power.....................................................................................................120V 60Hz AC or 230V 50Hz
Fuse .............................................................................................................................................13A 250V
Power Consumption .................................................................................... 1,328W (11.2A) max at 120V
Inrush Power...................................................................................................................... (11.2A) at 120V
Power Factor........................................................................................................................... 0.99 at 120V
Fuse ...............................................................................................................................................7A 250V
Power Consumption .......................................................................................1,325W (5.8A) max at 230V
Inrush Power...................................................................................................................... (1.83A) at 230V
Power Factor........................................................................................................................... 0.99 at 230V
THERMAL
Maximum ambient temperature .............................................................................................104°F (40°C)
CONTROL & PROGRAMMING
Data input............................................................................................5-pin & ground DIN5 female socket
Data pin configuration......pin1(LED), pin2(control), pin3(+5V), pin4(ground), pin5(none), ground(none)
ORDERING INFORMATION
Hurricane™ 1300...............................................................................................................................F1300
Wired manual remote (optional).........................................................................................................FC-M
Wired timer remote (included).............................................................................................................FC-T
Wireless manual remote (optional) ....................................................................................................FC-W
SPARE PARTS ORDERING INFORMATION
Master PCB.......................................................................................................................P170-F3MSPCB
Heater ...................................................................................................................................... 1P20-HT13
Pump................................................................................................................................... P200-F3PUMP
Fluid container ........................................................................................................................P170-F3FLC
Fluid sensor ........................................................................................................................ P170-F1FLOS
Thermal switch......................................................................................................................P170-THEF11
Bracket knob.....................................................................................................................P111-F3BKNOB
Fuse holder ......................................................................................................................P170-FUSEHOL
Manual fog button................................................................................................................P111-F3FOGB
WARRANTY INFORMATION
Warranty..................................................................................................................1-year limited warranty
Hurricane™ 1300 User Manual
14
3/26/2009 3:18 PM
|