Apple Heatsink Duct User Manual

Xserve  
Heatsink Duct  
Replacement Instructions  
Follow the instructions in this sheet carefully. Failure to follow these instructions could  
damage your equipment and void its warranty.  
Note: Online instructions covering customer-installable parts are available at  
Tools Required  
No tools are required for this procedure.You may, however, find a Phillips screwdriver  
useful in releasing the thumbscrews at the front of the server.  
Opening the Server  
The server slides open from the front of the rack. The top cover remains in place in the  
rack while the bottom housing (containing all internal components) should be placed on a  
sturdy, at surface.  
1. Alert users that the server will be unavailable for a period of time.  
2. Shut down the server.  
Warning:To avoid damaging internal components or causing injury, always  
shut down the server before opening it. After you shut down the server, internal  
components can be very hot. Let the server cool down before continuing.  
3. Write down the server’s serial number, which is located on the back panel. If it is  
necessary to set up the server’s software after you replace the heatsink duct, you will  
be asked for the serial number at login.  
073-0705 Rev. A  
9. Grasp the thumbscrews and slide the bottom housing forward part way to expose the  
two chassis levers. (Figure 2)  
10. While depressing both levers, pull the bottom housing all the way forward and remove  
it from the rack.  
Figure 2  
11. Place the bottom housing on a sturdy, at surface and ESD mat.  
12. Put on the ESD wrist strap.  
Xserve Heatsink Duct - 3  
Removing the Installed Heatsink Duct  
1. Release the latch on the heatsink duct from its slot, slide the duct away from the  
blower, and lift the end of the duct as shown. (Figure 3)  
2. Remove the duct from the server.  
Figure 3  
Installing the Replacement Heatsink Duct  
1. Insert the latch on the replacement heatsink duct into its slot.  
2. Rotate the heatsink duct down over the heatsink until the duct snaps into place.  
Closing the Server  
1. Carefully slide the bottom housing back into the rack.  
2. Tighten the front thumbscrews to secure it.  
Warning: Never turn on the server unless all of its internal and external parts  
are in place and it is closed. Operating the server when it is open or missing  
parts can damage it or cause injury.  
Xserve Heatsink Duct - 4  
Apple Computer, Inc.  
© 2002 Apple Computer, Inc. All rights reserved.  
This document is protected under U.S. Copyright Law and International Treaties, and no  
part of this document may be reproduced in any form without written permission from  
Apple.  
Apple is not responsible for typographical, printing, or inadvertent errors.  
Apple Computer, Inc.  
1 Infinite Loop  
Cupertino, CA 95014-2084  
USA  
+ 1 408 996 1010  
Apple, the Apple logo, Mac, Macintosh, and the Mac logo are trademarks of Apple  
Computer, Inc., registered in the U.S. and other countries. Xserve is a trademark of Apple  
Computer, Inc.  
Xserve Heatsink Duct - 5  

GE General Electric Convection Oven JBP64 User Manual
Garland Convection Microwave Oven User Manual
Frigidaire Gallery FGGC3065K User Manual
DoubleSight Displays DoubleSight DS 1700S User Manual
Belkin F5U249EA User Manual
Bakers Pride Oven BP 200 User Manual
Asko D3112 User Manual
ARM Limited Computer Hardware CM940T User Manual
Apple LOGIC EXPRESS 7 2 1 User Manual
Agilent Technologies 37907A User Manual