Xserve
Heatsink Duct
Replacement Instructions
Follow the instructions in this sheet carefully. Failure to follow these instructions could
damage your equipment and void its warranty.
Note: Online instructions covering customer-installable parts are available at
Tools Required
No tools are required for this procedure.You may, however, find a Phillips screwdriver
useful in releasing the thumbscrews at the front of the server.
Opening the Server
The server slides open from the front of the rack. The top cover remains in place in the
rack while the bottom housing (containing all internal components) should be placed on a
sturdy, flat surface.
1. Alert users that the server will be unavailable for a period of time.
2. Shut down the server.
Warning:To avoid damaging internal components or causing injury, always
shut down the server before opening it. After you shut down the server, internal
components can be very hot. Let the server cool down before continuing.
3. Write down the server’s serial number, which is located on the back panel. If it is
necessary to set up the server’s software after you replace the heatsink duct, you will
be asked for the serial number at login.
073-0705 Rev. A
9. Grasp the thumbscrews and slide the bottom housing forward part way to expose the
two chassis levers. (Figure 2)
10. While depressing both levers, pull the bottom housing all the way forward and remove
it from the rack.
Figure 2
11. Place the bottom housing on a sturdy, flat surface and ESD mat.
12. Put on the ESD wrist strap.
Xserve Heatsink Duct - 3
Removing the Installed Heatsink Duct
1. Release the latch on the heatsink duct from its slot, slide the duct away from the
blower, and lift the end of the duct as shown. (Figure 3)
2. Remove the duct from the server.
Figure 3
Installing the Replacement Heatsink Duct
1. Insert the latch on the replacement heatsink duct into its slot.
2. Rotate the heatsink duct down over the heatsink until the duct snaps into place.
Closing the Server
1. Carefully slide the bottom housing back into the rack.
2. Tighten the front thumbscrews to secure it.
Warning: Never turn on the server unless all of its internal and external parts
are in place and it is closed. Operating the server when it is open or missing
parts can damage it or cause injury.
Xserve Heatsink Duct - 4
Apple Computer, Inc.
© 2002 Apple Computer, Inc. All rights reserved.
This document is protected under U.S. Copyright Law and International Treaties, and no
part of this document may be reproduced in any form without written permission from
Apple.
Apple is not responsible for typographical, printing, or inadvertent errors.
Apple Computer, Inc.
1 Infinite Loop
Cupertino, CA 95014-2084
USA
+ 1 408 996 1010
Apple, the Apple logo, Mac, Macintosh, and the Mac logo are trademarks of Apple
Computer, Inc., registered in the U.S. and other countries. Xserve is a trademark of Apple
Computer, Inc.
Xserve Heatsink Duct - 5
|