Allied Telesis Computer Hardware x900 Advanced Gigabit Layer 3 Expandable Switches User Manual |
Network Resiliency Solutions
x900 Advanced Gigabit Layer 3+ Expandable Switches
Tested Solution: VCStack + Link Aggregation
Prior to the advent of theVirtual Chassis Stacking (VCStack) solution, high availability in enterprise networks was achieved by
provisioning redundant links (with STP) and redundant routers (withVRRP). In normal operation, bandwidth and routing power would
sit idle in the network.
AlliedTelesis now provides a truly resilient network. In normal operation, all bandwidth and all routing power in the network are fully
available for use all the time. If a link or device fails, some of the bandwidth or forwarding power will be lost, but the network will still
be fully operational and all remaining resources will continue to be fully utilized.
Servers
8600
x900
8000S
CORE
8000S
Stack
1 Gigabit link
10/100 link
Link aggregation
EDGE
Diagram 1: VCStack + Link Aggregation
Key Benefits of the solution
Full bandwidth utilization and maximum availability
The key advantage comes from configuring the links from the edge to the core using 802.3ad link aggregation.This is possible
becauseVCS supports link aggregation on ports across different virtual chassis members, providing:
■
■
Full network bandwidth, as both ports are active; no links are blocked, as some would be with spanning tree.
Minimal network disruption if a link fails.The process within a switch when an aggregated link fails is very simple and the virtual
chassis almost instantly adapts its data forwarding on the loss of the link.
Allied Telesis
NETWORK RESILIENCY SOLUTIONS |VCStack + Link aggregation
x900 Configuration
All log messages are sent to a syslog server. Higher-severity
log messages are also buffered on the switch itself
log buffered level errors
log host 192.168.10.11
log host 192.168.10.11 level debugging
access-list 1 permit 192.168.10.13
snmp-server enable trap auth nsm
snmp-server community public ro 1
snmp-server host 192.168.10.13 version 2c public
Allow read-only SNMP monitoring from one management
station
A resiliency link backs up the dedicated stacking link. If the
stacking link fails, communication is maintained to allow
graceful reconfiguration
stack resiliencylink eth0
stack 1 priority 1
Use priority to pre-elect theVCStack master switch
CreateVLANs.VLAN 169 for servers, andVLANs 170-172
for connectivity to edge switches
vlan database
vlan 169-172 state enable
interface port1.0.1
switchport
switchport mode access
switchport access vlan 169
static-channel-group 1
interface port2.0.1
switchport
switchport mode access
switchport access vlan 169
static-channel-group 1
Create link aggregation groups across theVCStack
members for resiliency. One for servers, and three for
edge switches
interface port1.0.3
switchport
switchport mode access
switchport access vlan 170
static-channel-group 2
interface port2.0.3
switchport
switchport mode access
switchport access vlan 170
static-channel-group 2
interface port1.0.5
switchport
switchport mode access
switchport access vlan 171
static-channel-group 3
Allied Telesis
NETWORK RESILIENCY SOLUTIONS |VCStack + Link aggregation
interface port2.0.5
switchport
switchport mode access
switchport access vlan 171
static-channel-group 3
interface port1.0.7
switchport
switchport mode access
switchport access vlan 172
static-channel-group 4
Create link aggregation groups across theVCStack
members for resiliency. One for servers, and three for
edge switches
interface port2.0.7
switchport
switchport mode access
switchport access vlan 172
static-channel-group 4
interface vlan169
ip address 192.168.169.1/24
interface vlan170
ip address 192.168.170.1/24
ip dhcp-relay server-address 192.168.169.254
Assign an IP address to eachVLAN. Configure DHCP relay
to forward DHCP requests to the server
interface vlan171
ip address 192.168.171.1/24
ip dhcp-relay server-address 192.168.169.254
interface vlan172
ip address 192.168.172.1/24
ip dhcp-relay server-address 192.168.169.254
Configure a default route to external networks
ip route 0.0.0.0/0 192.168.169.254
ntp server 192.168.10.11
end
Configure NTP (NetworkTime Protocol) with the IP
address of the NTP server
Allied Telesis
NETWORK RESILIENCY SOLUTIONS |VCStack + Link aggregation
8600 Configuration
To enable secure HTTP management to use certificates, a
distinguished name is required and system security must
be enabled
set system distinguished="cn=switch1, o=alliedtelesis, c=nz"
enable system security
Storm control is configured to prevent downstream loops
from affecting the inner layers of the network
set switch port=1-24 bclimit=3000 mclimit=3000 dlflimit=3000
create vlan="edge" vid=171
add vlan="171" port=1-26
By default, all ports are put intoVLAN 171
enable stp="default"
set stp="default" mode=rapid
disable stp="default" port=1-24
Spanning tree needs to be disabled on the edge-facing
ports, as it cannot co-exist with 802.1x authentication
The two gigabit ports are aggregated together to create a
resilient link to the network core
create switch trunk=aggregation port=25-26 speed=1000m
802.1x authentication is enabled on all the client-facing
ports. Clients cannot access the network without being
authenticated
enable portauth=8021x
enable portauth=8021x port=1-24 type=authenticator
enable dhcpsnooping
enable dhcpsnooping arpsecurity
enable dhcpsnooping log=arpsecurity
set dhcpsnooping port=25 trusted=yes
set dhcpsnooping port=26 trusted=yes
DHCP snooping guards against rogue server attacks, server
exhaustion attacks, arp poisoning attacks and IP spoofing
attacks. Any ARP poisoning attempt will be logged
enable ip
Attach a management IP address toVLAN171, and provide
a default gateway address
add ip int=vlan171 ip=192.168.171.34
add ip route=0.0.0.0 interface=vlan171 nexthop=192.168.171.1
The Radius server is used for authenticating management
sessions and also for authenticating 802.1x clients.
add radius server=192.168.10.34 secret="testing123-2"
port=1812 accport=1813
add switch l3filter match=dipaddress dclass=host
add switch l3filter=1 entry dipaddress=192.168.171.34
action=deny
add switch l3filter match=none import=true
add switch l3filter=2 entry iport=26 action=nodrop
add switch l3filter=2 entry iport=25 action=nodrop
Management access is ONLY possible via the core-
connected aggregated link. Access via insecure methods
Telnet and HTTP are blocked
disable telnet server
Allied Telesis
NETWORK RESILIENCY SOLUTIONS |VCStack + Link aggregation
enable ssh server serverkey=1 hostkey=0 expirytime=1
logintimeout=60
add pki certificate="cer_name" location=cer_name.cer trust=true
set http server security=on sslkey=2 port=443
Remote management sessions must use SSH and/or
HTTPS
All log messages are sent to a syslog server.
Higher-severity log messages are also buffered on the
switch itself
create log output=1 destination=syslog server=192.168.10.11
secure=yes message=20
add log output=1 filter=1 severity=>1
enable snmp
enable snmp authenticate_trap
Allow read-only SNMP monitoring from one management
station. Send traps to that same management station
create snmp community=public
enable snmp community=public trap
add snmp community=public manager=192.168.10.13
add snmp community=public traphost=192.168.10.13
enable ntp
add ntp peer=192.168.10.3
System time is provided from an NTP server
Allied Telesis
NETWORK RESILIENCY SOLUTIONS |VCStack + Link aggregation
8000S Configuration
interface range ethernet 1/e(1-24),2/e(1-24)
Broadcast and multicast limiting prevent downstream loops
port storm-control broadcast enable
from affecting the inner layers of the network
port storm-control include-multicast
exit
interface range ethernet 1/e(1-24),2/e(1-24)
spanning-tree portfast
spanning-tree guard root
exit
The client-facing ports are configured as portfast so there
is no delay in connectivity when client devices attach. Root
guard protects against STP spoofing attacks
interface range ethernet 1/e(1-24),2/e(1-24)
Port security guards against MAC spoofing attacks, and
limits the ability for intruders to connect to the network
port security mode max-addresses
port security max 3
port security discard trap 60
exit
vlan database
default-vlan vlan 170
exit
By default, all ports are put intoVLAN 170
Two gigabit ports, one from each stack member, are
aggregated together to create a resilient link to the
network core
interface range ethernet 1/g1,2/g1
channel-group 1 mode on
exit
dot1x system-auth-control
interface range ethernet 1/e(1-24),2/e(1-14)
dot1x single-host-violation discard trap 30
dot1x re-authentication
802.1x authentication is enabled on all the client-facing
ports. Clients cannot access the network without being
authenticated
dot1x port-control auto
exit
ip dhcp snooping
ip dhcp snooping vlan 170
interface port-channel 1
ip dhcp snooping trust
exit
DHCP snooping guards against rogue server and server
exhaustion attacks
interface vlan 170
ip address 192.168.170.45 255.255.0.0
exit
Attach a management IP address toVLAN170, and provide
a default gateway
ip default-gateway 192.168.170.1
Allied Telesis
NETWORK RESILIENCY SOLUTIONS |VCStack + Link aggregation
radius-server host 192.168.10.34 auth-port 1812 acct-port 1813
key testing123-2
aaa authentication login default radius local
aaa authentication dot1x default radius
The Radius server is used for authenticating management
sessions and also for authenticating 802.1x clients
management access-list mlist
deny service telnet
deny service http
Management access is ONLY possible via the core-
connected aggregated link. Access via insecure methods
Telnet and HTTP are blocked
permit port-channel 1
exit
management access-class mlist
Remote management sessions must use SSH and/or
HTTPS
ip ssh server
ip https server
All log messages are sent to a syslog server.
Higher-severity log messages are also buffered on the
switch itself
logging 192.168.10.11
logging buffered errors
Allow read-only SNMP monitoring from one management
station. Send traps to that same management station
snmp-server community public ro 192.168.10.13 view Default
snmp-server host 192.168.10.13 public traps 2
sntp client enable vlan 170
clock source sntp
sntp unicast client enable
sntp server 192.168.10.3
System time is provided from an SNTP server
line console
autobaud
exit
The console port can auto-detect the terminal data rate
Allied Telesis
NETWORK RESILIENCY SOLUTIONS |VCStack + Link aggregation
About AlliedTelesis
AlliedTelesis is a world class leader in delivering IP/Ethernet network solutions to the
global market place.We create innovative, standards-based IP networks that seamlessly
connect you with voice, video and data services.
Enterprise customers can build complete end-to-end networking solutions through a
single vendor, with core to edge technologies ranging from powerful 10 Gigabit Layer 3
switches right through to media converters.
AlliedTelesis also offer a wide range of access, aggregation and backbone solutions for
Service Providers. Our products range from industry leading media gateways which
allow voice, video and data services to be delivered to the home and business, right
through to high-end chassis-based platforms providing significant network infrastructure.
AlliedTelesis' flexible service and support programs are tailored to meet a wide range
of needs, and are designed to protect your AlliedTelesis investment well into the future.
USA Headquarters | 19800 North Creek Parkway | Suite 100 | Bothell | WA 98011 | USA | T: +1 800 424 4284 | F: +1 425 481 3895
European Headquarters |Via Motta 24 | 6830 Chiasso | Switzerland | T: +41 91 69769.00 | F: +41 91 69769.11
Asia-Pacific Headquarters | 11 Tai Seng Link | Singapore | 534182 | T: +65 6383 3832 | F: +65 6383 3830
© 2008 AlliedTelesis Inc.All rights reserved. Information in this document is subject to change without notice. All company names, logos, and product designs that are trademarks or registered trademarks are the property of their respective owners. 617-000170 Rev. L
|