AMX Modero NXD CV5 User Manual

Operation/Reference Guide  
®
Modero CV5  
G4 Touch Panel  
NXD-CV5  
5” Modero Widescreen Video Touch Panels  
Last Revised: 10/1/2008  
Touch Panels  
Table of Contents  
Table of Contents  
i
5" Modero Widescreen Touch Panel  
Table of Contents  
ii  
5" Modero Widescreen Touch Panel  
Table of Contents  
iii  
5" Modero Widescreen Touch Panel  
Introduction  
Introduction  
The NXD-CV5 5" Modero Widescreen Color Video Touch Panels (FIG. 1) are the industry’s first  
widescreen mini-touch panels and are available only through AMX.  
NXD-CV5 (front view)  
(FG2261)  
FIG. 1 Sample 5" Video Touch Panel  
This is the first 5" diagonal Widescreen Color Active video-capable touch panel in the control and  
automation industry. This Color Video (CV) panel displays NTSC/MPAL/PAL/SECAM video formats  
within variable sized windows up to 800 x 480. It includes a built-in microphone, speakers,  
audio/headphone connector, and six NetLinx programmable pushbuttons.  
This panel currently supports Intercom functionality which allows two communicating CV5 panels (the  
NetLinx Master must control all intercom and paging) to transmit half-duplex audio signals over a  
network and be used as an Intercom system. Audio and Video is delivered to the panel via a CAT5  
connection from an optional NXA-AVB/ETHERNET Breakout Box.  
The NXD-CV5 panel (FG2261) is shipped, by default with a Trim Ring containing  
buttons. The user can later choose to alter the Faceplate/Trim Ring configuration of  
the CV5 touch panel by choosing the install the included No-Button Trim RIng.  
Key features common to both panels include:  
CV5 panels are based on the latest display technology and support AMX's 4th generation (G4)  
graphics which provide higher brightness, richer colors, and deeper contrast. The new G4  
graphics technology is supported by the latest AMX TPDesign4 Touch Panel Design program.  
CV5 panels display eye-catching images and full-motion video on a large 16:9 image format,  
while providing a wide 90-degree top-to-bottom viewing angle.  
CV5 panels feature a front panel light sensor, motion sensor, IR receiver and a Sleep/Setup  
Access combo button.  
CV5 panels support AMX Computer Control, which enables remote viewing and control of  
any networked computer directly from the panel. This gives the user the ability to launch  
digital music from a PC, cruise the Internet, check and respond to E-mail, open software files,  
and launch applications. Anything you can do on your PC can be accomplished through these  
panels.  
1
5" Modero Widescreen Touch Panel  
   
Introduction  
CV5 panels feature programmable firmware that can be upgraded via either the Ethernet port  
or the mini-USB port.  
NXD-CV5 (shown with Button Trim Ring installed)  
Programmable  
Buttons/LEDs  
(1-3)  
Programmable  
Buttons/LED  
(4-6)  
Sleep/Setup Access Button  
FIG. 2 NXD-CV5 (front view showing default Trim Ring)  
CV5 Specifications  
The following table outlines the specifications for the 5" Widescreen Modero panel.  
Specifications for 5" Widescreen Video Touch Panel  
Dimensions (HWD):  
• NXA-RK5 (optional): metal rack-mount with black matte finish:  
(3 RU - rack units high)  
5.22" x 19.0" x 0.50" (13.26 cm x 48.26 cm x 1.27 cm)  
• NXD-CV5 (with faceplate): 4.15" x 5.59" x 3.23"  
(10.50 cm x 14.20 cm x 8.20 cm)  
• CB-TP5 Rough-In/Wallbox (optional): 4.27" x 5.14" x 3.40"  
(10.86 cm x 13.06 cm x 8.64 cm)  
Power Requirements  
(stand-alone CV5):  
• Constant current draw: 650 mA @ 12 VDC  
• Startup current draw: 1.3 A @ 12 VDC  
• 64 MB SDRAM  
Memory (factory default):  
• 64 MB Flash Memory (not upgradeable - factory programmed)  
• 1.76 lbs (0.80 kg)  
Weight:  
Certifications:  
Panel LCD Parameters:  
• FCC Part 15 Class B, CE, and IEC 60950  
• Aspect ratio: 16 x 9  
2
• Brightness (luminance): 170 cd/m  
• Channel transparency: 8-bit Alpha blending  
• Contrast ratio: 250:1  
• Display colors: 256 thousand colors (18-bit color depth)  
• Dot/pixel pitch: 0.14 mm  
• Panel type: TFT Color Active-Matrix  
• Screen resolution: 800 x 480 pixels (HV) @ 60 Hz frame frequency  
• Video format: NTSC, MPAL, PAL, and SECAM  
• Viewing dimensions: 4.3" x 2.58" (109.2 mm x 65.2 mm)  
• 4.25” x 2.55” (10.80cm x 6.48cm)  
Active Screen Area:  
2
5" Modero Widescreen Touch Panel  
   
Introduction  
Specifications for 5" Widescreen Video Touch Panel (Cont.)  
Viewing Angles:  
• 90° total viewing angle:  
- Horizontal: + 45° (left and right from center)  
IR Reception Angle:  
• Horizontal: + 25° (left and right from center)  
• Vertical: + 15° (up and down from center)  
Supported Audio Sample  
Rates:  
• 48000Hz, 44100Hz, 32000Hz, 24000Hz, 22050Hz, 16000Hz, 12000Hz,  
11025Hz, and 8000Hz.  
Front Panel Components:  
Light sensor:  
• Photosensitive light detector for automatic adjustment of the panel brightness  
(a dim room results in a dimmer LCD display, and a bright room results in a  
brighter LCD display).  
Note: The light sensor can be adjusted via the Sensor Setup page (page 78).  
Motion sensor (PIR):  
IR Receiver:  
• Proximity Infrared Detector to wake the panel when the panel is approached.  
• Activation range: + 25° (left and right from center) and + 15° (up and down  
from center).  
Note: This sensor can be adjusted via the Sensor Setup page (see page 78).  
• IR reception 38 KHz and 455 KHz IR frequencies.  
• The IR receiver is located beneath the translucent Front Setup button. When  
an IR code is detected it is sent to the NetLinx Master as a push on the  
appropriate AMX IR channel.  
• IR receivers and transmitters on G4 panels share the device address number  
of the panel.  
Front setup access button: • Provides both access to the Setup and Calibration page and toggles the  
panel between a "sleep" or "wake" state.  
- When wired, "sleep" status means the backlight is Off.  
- When battery operated, wireless "sleep" status means the touch panel  
base is either Off or "suspended".  
Microphone:  
• Used for intercom applications  
(requires the NXA-AVB/ETHERNET Breakout Box for analog  
communication)  
Speakers:  
• Stereo output with a frequency response of 500 Hz - 7 KHz  
• 6 programmable pushbuttons  
Buttons:  
Side Panel Components:  
PWR connector:  
Ethernet 10/100 port:  
• 2-pin 3.5 mm mini-Phoenix connector.  
• RJ-45 port for 10/100 Mbps communication. The Ethernet port automatically  
negotiates the connection speed (10 Mbps or 100 Mbps), and whether to use  
half duplex or full duplex mode.  
• CV5 panels communicate with the NetLinx Master using the ICSP protocol  
over Ethernet.  
Ethernet 10/100 LEDs:  
• LEDs show communication activity and connection information:  
A-activity - Yellow LED lights when receiving or transmitting Ethernet data  
packets.  
L-link - Green LED lights when the Ethernet cables are connected and  
terminated correctly.  
Stereo Output connector:  
• Stereo output through a 3.5mm mini-jack (for use with external speakers or  
headphones).  
3
5" Modero Widescreen Touch Panel  
Introduction  
Specifications for 5" Widescreen Video Touch Panel (Cont.)  
Side Panel Components  
(Cont.):  
Mini-USB connector:  
• 5-pin Mini-USB connector used for programming, firmware update, and touch  
panel file transfer between the PC and the target panel.  
Note: When connecting the panel to PC using a CC-USB (or compatible)  
cable, be sure to power the panel On before attempting to connect the USB  
cable from the PC to the mini-USB port on the panel. Refer to the Configuring  
information.  
USB connector:  
• Type-A USB port can connect an external keyboard or mouse device for use  
with Virtual PC applications.  
Note: External USB input devices (keyboard or mouse) must be plugged into  
the rear/side USB connector before the unit is powered-up. The panel will not  
detect these USB input devices until the unit cycles power.  
Audio/Video connector:  
• RJ-45 connector for communication of differential audio/video signals  
to/from the touch panel (panel type dependant). This connector receives  
Composite video, Stereo (left/right) audio, and microphone audio.  
• Video is received via the NXA-AVB/ETHERNET Breakout Box. Configuring  
video windows for playback is done using TPDesign4.  
• In-bound audio (from the breakout box) gets directed to the speakers.  
• Out-bound audio is sent from the on-board microphone (on the  
front-panel). Selecting audio files for playback is configured through  
TPDesign4.  
Button Assignments:  
Button assignments can only be adjusted in TPD4 and not on the panels.  
• Button channel range: 1 - 4000 button push and feedback (per address port)  
• Button variable text range: 1 - 4000 (per address port)  
• Button states range: 1 - 256 (General Button; 1 = Off State, 2 = On State)  
• Level range: 1 - 600 (default level value 0-255, can be set up to 1-65535)  
• Address port range: 1 - 100  
Operating / Storage  
Environment:  
• Operating Temperature: 0° C (32° F) to 40° C (104° F)  
• Operating Humidity: 20% - 85% RH  
• Storage Temperature: -20° C (-4° F) to 60° C (140° F)  
• Storage Humidity: 5% - 85% RH  
Included Accessories:  
• Installation Kit for NXD-CV5 panels (KA2261-01):  
- 2-pin 3.5 mm mini-Phoenix connector  
- Three Drywall clips (62-5924-05) and #6 - sheet metal screws  
- Three Phillips-head screws (#4-40 x 0.250 Black)  
• Mounting Template - Flush Mount Drywall Installation  
• Trim Ring with button openings (60-2261-04) (factory installed)  
• Trim Ring without button openings (60-2261-05)  
• CB-TP5 Rough-In/Wallbox (FG038-10)  
Other AMX Equipment:  
• NXA-AVB/ETHERNET Breakout Box (FG2254-10)  
- Provides video/audio distribution to the A/V panel over CAT5 cable  
(up to 200’/60.96 m) and accepts either Composite or S-Video  
• NXA-BEZ-5B, Bezel Kit with buttons for Modero 5” Widescreen Wall/Flush  
Mount Touch Panel (NXD-CV5)  
- NXA-BEZ-5B-BG, Beige Faceplate with beige buttons (FG2261-32)  
- NXA-BEZ-5B-BL, Black Faceplate with black buttons (FG2261-30)  
- NXA-BEZ-5B-LA, Light Almond Faceplate with light almond buttons  
(FG2261-33)  
- NXA-BEZ-5B-WH, White Faceplate with white buttons (FG2261-31)  
4
5" Modero Widescreen Touch Panel  
Introduction  
Specifications for 5" Widescreen Video Touch Panel (Cont.)  
Other AMX Equipment  
(Cont.):  
• NXA-BEZ-5NB, Bezel Kit without buttons for Modero 5” Widescreen Wall/  
Flush Mount Touch Panel (NXD-CV5)  
- NXA-BEZ-5NB-BG, Beige Faceplate without buttons (FG2261-42)  
- NXA-BEZ-5NB-BL, Black Faceplate without buttons (FG2261-40)  
- NXA-BEZ-5NB-LA, Light Almond Faceplate without buttons (FG2261-43)  
- NXA-BEZ-5NB-WH, White Faceplate without buttons (FG2261-41)  
• NXA-CV5AM, Modero 5" Angle Mount Kit (FG2904-56):  
- Wedge for 5" WallMount  
- Wedge Mounting Template - Flush Mount Drywall Installation  
- Three 1/8" diameter by 3" length Toggle Bolts (with wings)  
- Three 4-20 x.375 LG screws, PPH, Plastite, Black Zinc  
• NXA-RK5 RackMount Kit for 5" Wall Mount panels (FG2904-55):  
- 5" RakMount  
- Four Screws, #10-32 x.625, PH Truss, BLK  
- Four Washers, #10, Black Nylon  
- Three Screws, #4-40 x.250, PPH, BLK  
It is recommended that firmware KIT files only be transferred over a direct USB or  
Ethernet connection and only when the panel is connected to a power supply. If  
battery power fails during a firmware upgrade, the panel flash file system may  
become corrupted.  
CV5 Panels - Connector Layout  
FIG. 3 shows the layout of the connectors (located on the left side panel of the NXD-CV5 panel).  
Stereo Output  
Audio-Video from  
NXA-AVB/ETHERNET (CAT5)  
Keyboard/Mouse  
(USB)  
Ethernet (CAT5)  
Power  
ETHERNET  
AUDIO / VIDEO  
PWR  
12VDC  
A
L
Mini-USB (Program)  
FIG. 3 Connector layout and location on the CV5 touch panel  
5
5" Modero Widescreen Touch Panel  
   
Introduction  
6
5" Modero Widescreen Touch Panel  
CV5 Touch Panel Accessories  
CV5 Touch Panel Accessories  
The following section outlines and describes both the included accessories and other AMX equipment  
available for these touch panels.  
NXA-AVB/ETHERNET Breakout Box (FG2254-10)  
The NXA-AVB/ETHERNET Breakout Box (FIG. 4) is sold as a separate accessory to the CV5 panel and  
does not come as part of a Kit configuration for this panel. This box facilitates the installation and  
distribution of video, data, and audio to Modero touch panels located up to 200 feet (60.96 m) from the  
AVB box. This unit accepts either Composite or S-Video from standard video devices.  
This breakout box can be mounted on either a horizontal flat surface or within an equipment rack  
(by using an optional AC-RK Rack Kit).  
Composite/  
S-Video  
Luma  
Ethernet (to panel)  
S-Video Chroma  
Power In  
(rear)  
(front)  
Audio  
In  
Audio/Video  
(to panel)  
Ethernet In  
Mic Out  
Power (to panel)  
FIG. 4 NXA-AVB/ETHERNET Breakout Box (front and rear views)  
Product Specifications  
NXA-AVB/ETHERNET Specifications  
Dimensions (HWD):  
• 1.50" x 5.55" x 4.88" (3.81 cm x 14.10 cm x 12.40 cm)  
• Width when attached to mounting ears: 6.65" (16.89 cm)  
• 50mA (with audio/video input)  
Power Consumption:  
• 23mA (with no audio/video)  
• Routed through NXA-AVB/Ethernet using a 12 VDC-compliant power supply  
• FCC Part 15 Class B, CE, and EN60950  
Certifications:  
Features:  
• Accepts either Composite or S-Video (video-capable panels only)  
• Provides audio distribution to the non-video touch panels over a CAT5 cable  
(up to 200 ft.)  
• Provides video/audio distribution to the video-capable touch panels over  
CAT5 cable up to 200 ft.(60.9 m)  
Availability:  
• This unit is included with CV5, CV7, CV10, and 1200V-Series Kit  
configurations  
Front Components:  
• 2-pin 3.5 mm Phoenix connector for power to the touch panel  
• Green LED provides an indication of power status  
• RJ-45 connector provides Ethernet signals to the touch panel  
• RJ-45 connector provides differential audio and video signals to the touch  
panel (panel type dependant)  
7
5" Modero Widescreen Touch Panel  
       
CV5 Touch Panel Accessories  
NXA-AVB/ETHERNET Specifications (Cont.)  
Rear Components:  
• 6-pin 3.5 mm Phoenix connector for in-bound (left/right channel) audio  
• 4-pin 3.5 mm Phoenix connector for out-bound (from microphone) audio  
• BNC connector (female) for Composite or Chroma (for video-capable  
panels only)  
• BNC connector (female) for luminance (for video-capable panels only)  
• RJ-45 connector for Ethernet input from the control system  
• 2-pin 3.5 mm Phoenix connector for in-bound power  
• Two 2-pin Phoenix connectors (41-5025)  
Included Accessories:  
Other AMX Equipment:  
• 4-pin Phoenix connector (41-5047)  
• 6-pin Phoenix connector (41-5063)  
• Rack Mount Kit (KA2250-40) with mounting bracket (62-2254-02)  
• AC-RK Accessory RackMount Kit (FG515)  
• Modero Table Top Cable (CA2250-50)  
Installing the NXA-AVB/ETHERNET  
A 12 VDC-compliant power supply can indirectly provide power to a Modero panel by routing power  
through the NXA-AVB/ETHERNET Breakout Box. FIG. 5 shows a sample wiring configuration using  
both an indirect or direct power connection for a video-capable Modero panel.  
Indirect  
Connect  
Line Level out  
(to amplifier  
or VOL card)  
Mic Out  
Ethernet In  
(RJ-45)  
(4-pin captive-wire)  
12 VDC power  
supply  
Video In  
(BNC)  
Audio In  
(6-pin captive-wire)  
(rear)  
NXA-AVB/ETHERNET  
Breakout Box  
Power  
supplied via  
(front)  
NXA-AVB box  
Ethernet  
(CAT5)  
Audio/Video  
(CAT5)  
12 VDC power  
supply  
or  
Direct  
Connect  
NXD/T Video-capable  
Touch Panels  
FIG. 5 Sample wiring configuration on video-capable panels using this breakout box  
A 12 VDC-compliant power supply can also directly provide power through the unit to a target Modero  
panel. FIG. 6 shows a sample wiring configuration for a non-video capable Modero panel.  
Direct  
connect  
Ethernet  
(CAT5)  
Audio (CAT5)  
between the  
NXA-AVB/ETHERNET  
Breakout Box  
12 VDC power  
supply  
NXD/T Non-video capable  
Touch Panels  
FIG. 6 Sample wiring configuration using non-video capable Modero panels  
8
5" Modero Widescreen Touch Panel  
     
CV5 Touch Panel Accessories  
The breakout box unit can be mounted on either a horizontal flat surface or into an  
equipment rack (by removing the front screws and attaching it to an optional AC-RK).  
The power supply being used on the NXA-AVB/ETHERNET is dependant on the  
power requirements of the target touch panel.  
Use a standard CAT5 Ethernet cable to provide both communication and 10/100 network connectivity  
between the panel, NXA-AVB/ETHERNET, NetLinx Master, and the network.  
Wiring the NXA-AVB/ETHERNET connectors and cables  
The inputs and outputs on the breakout box are separated into front and rear connectors. The rear  
connectors are used to input external signals. The front connectors are used to communicate signals  
between the NXA-AVB/ETHERNET and a target Modero panel. FIG. 7 provides a layout of the wiring  
connection both into and from the breakout box.  
GND  
F
R
O
N
T
Audio In - Left Channel  
In (-)  
(6-pin captive wire)  
In (+)  
GND  
In (-)  
Audio In - Right Channel  
(6-pin captive wire)  
In (+)  
GND(-)  
Out (-)  
Microphone Out  
Out (+)  
(4-pin captive wire)  
Comp/Y (BNC)  
C (BNC)  
Audio/Video  
(CAT5)  
Ethernet  
(RJ-45)  
Ethernet Out  
(CAT5)  
R
E
A
R
Power to  
touch panel  
12 VDC power  
supply  
FIG. 7 NXA-AVB/ETHERNET Breakout Box connector wiring diagram  
The rear-panel wiring connections are described below (from left to right):  
• AUDIO IN:  
6-pin mini-Phoenix connector, divided into left and right audio channels. Each  
channel is divided into GND, IN+, and IN- terminal cable connectors  
(2 sets of 3 for each channel).  
An example of this cable is to strip the ends of 2 RCA audio cables and insert  
them into their respective locations on the Audio In port.  
Either a balanced (+, -, and GND) or unbalanced (+ and GND) audio  
signal can be connected to this input.  
• MIC OUT:  
4-pin mini-Phoenix connector, divided into GND, OUT-, and OUT+ terminal  
connectors.  
An example of this cable is to strip the terminal ends of a 3.5mm mini-jack and  
insert them into their respective locations on the Mic Out port. This signal can  
be fed as a Line Level In to either an amplifier or an AMX VOL card.  
Either a balanced (+, -, and GND) or unbalanced (+ and GND) audio signal  
can be connected to this output.  
• Video In BNCs: Feeds either Composite/S-Video Luma or S-Video Chroma signals into the  
NXA-AVB/ETHERNET. This feed is then redirected out to a Modero panel  
through the front Audio/Video CAT5 port.  
• ETHERNET:  
RJ-45 connector routes data to the G4 touch panel through the front Ethernet  
port. These connections use a standard CAT5 Ethernet cable to provide  
communication between the target touch panel, breakout box, and NetLinx  
Master.  
9
5" Modero Widescreen Touch Panel  
   
CV5 Touch Panel Accessories  
• PWR:  
2-pin mini-Phoenix connector that connects to a 12 VDC-compliant power  
supply. This port can be used to provide power to a Modero panel by sending it  
through the NXA-AVB/ETHERNET (rear power connector through to the front  
power connector).  
Wiring the NXA-AVB/ETHERNET for Unbalanced Audio  
Most domestic audio equipment has unbalanced audio inputs and outputs. This means that the audio  
output (left, right, or mono) appears on a single wire, and is referenced to "0 V" or "Ground". Typical  
connectors used are RCA "phono" connectors, DIN plugs/sockets, and 0.25" (6.3mm) or 3.5mm jack  
plugs/sockets.  
Unbalanced audio is adequate for most domestic environments and for line-level signals in a typical  
broadcast studio. Problems may occur if the signals are carried over long distances, especially if the  
source and destination have separate main supplies. Use the following wiring drawing (FIG. 8) to  
configure an unbalanced audio connection.  
GND  
Unbalanced IN  
(Jumper IN- to GND)  
Left Channel  
IN-  
IN+  
GND  
Unbalanced IN  
(Jumper IN- to GND)  
Right Channel  
Microphone  
IN-  
IN+  
AUDIO IN  
MIC OUT  
GND  
Unbalanced OUT  
OUT-  
OUT+  
FIG. 8 Wiring the rear AUDIO IN and MIC OUT for use with Unbalanced Audio  
When using unbalanced audio for the AUDIO IN connector (FIG. 8), the "-" and the "GND" terminals  
should be connected together and then connected to the GND of the unbalance audio signal. When  
connecting to an unbalanced audio input from the MIC OUT connector (FIG. 8), wire the "+" terminal to  
the signal input, and the "GND" terminal to the signal ground.  
Wiring the NXA-AVB/ETHERNET for Balanced Audio  
Professional audio equipment will often use balanced audio inputs and outputs, usually on 3-pin "XLR"  
connectors. A balanced audio signal consists of a pair of wires carrying the audio signal in anti-phase  
with each other (if one wire carries a positive voltage, the other carries an equal and opposite negative  
voltage).  
The advantage of balanced audio over unbalanced audio is its ability to reject external interference added  
as the signal is carried over the wire. The receiving equipment takes the voltage difference between the  
two wires as the input signal. Interference will usually get added to both wires equally, and so gets  
cancelled by the receiving equipment.  
10  
5" Modero Widescreen Touch Panel  
     
CV5 Touch Panel Accessories  
The 3 wires used in a typical XLR lead are often referred to as Ground, Live (Hot) and Return (Cold).  
"Live" and "Return" carry the "in-phase" and "out-of-phase" versions of the audio respectively. The pins  
of the XLR plug/socket are as follows:  
• X = Ground  
• L = Live (Hot)  
• R = Return (Cold)  
When connecting the MIC OUT connector to a balanced audio input (FIG. 9), use all three audio  
terminals (+, -, and GND), then connect the "+" terminal to the "live" signal, the "-" terminal to the  
"return" signal, and the "GND" terminal to the ground signal.  
Ground signal  
GND  
Return signal  
Balanced OUT  
OUT-  
Line signal  
OUT+  
FIG. 9 Wiring the rear MIC OUT connector for use with Balanced Audio  
Each bundle of 4 twisted pairs includes a colored tape indicator for identification.  
11  
5" Modero Widescreen Touch Panel  
 
CV5 Touch Panel Accessories  
12  
5" Modero Widescreen Touch Panel  
Installation  
Installation  
This NXD panels can be installed into either a pre-wall surface (using a CB-TP5 rough-in/wallbox) or a  
solid surface (using either solid surface or drywall screws).  
Unpacking the Panel  
1. Inspect and confirm the contents of the shipment box to verify you have all specified parts. Refer to  
about included accessories and other AMX equipment.  
2. Carefully remove the panel from the shipping box.  
3. Carefully peel the protective plastic cover from the LCD.  
If the protective plastic LCD cover is not removed, the panel may not respond  
properly to touch points on the LCD or allow proper screen calibration.  
Installing the No-Button Trim Ring  
The NXD-CV5 panel is shipped from AMX with the default Button Trim Ring already installed. The  
unit is also shipped with an included Trim Ring containing no button openings (a No-Button Trim Ring)  
that allows you, if desired, to change the default configuration of the NXD panel Faceplate to that with  
no-button openings. In order to install this included No-Button Trim Ring, you must first remove the  
factory-installed default Button Trim Ring and its six small buttons.  
1. The Faceplate is secured to the panel with plastic latches. To remove the Faceplate, simply pull it  
away from the panel by gently tugging it outwards until the entire Faceplate comes away from the  
panel.  
2. Turn the Faceplate over to expose the inside surface and view the Trim Ring latches (FIG. 10).  
3. In a single motion, press down and then outwards on the two Trim Ring latches located along the  
top of the internal surface of the Faceplate to begin removing the Button Trim Ring. Removing the  
Internal Faceplate from the panel exposes the pushbuttons along the inside of the Internal  
Faceplate.  
4. Gently tug along the edges of the Button Trim Ring and work your way around the edges to remove  
it from the Faceplate (FIG. 10).  
5. From along the internal surface of the Faceplate, remove the six buttons by gently bending each  
Button latch up and pulling the button outwards.  
6. Grasp the No-Button Trim Ring on both sides and fit it into the groove along the outside surface of  
the Faceplate (made available by the removal of the previous Trim Ring).  
7. Gently insert the Trim Ring latches into their corresponding openings on the outer surface of the  
internal Faceplate (FIG. 11).  
13  
5" Modero Widescreen Touch Panel  
     
Installation  
CV5 Panel/enclosure  
Button latch  
Trim  
Ring  
Latches  
Button removal  
(showing the internal surface of Faceplate)  
Default Button Trim Ring  
(with button openings)  
Faceplate  
(outside surface shown)  
FIG. 10 Removing the default Button Trim Ring  
No-Button Trim Ring  
Hollow button openings  
Faceplate (outer surface shown)  
FIG. 11 Inserting the No-Button Trim Ring  
8. Firmly press down around the No-Button Trim Ring until all of the latches are securely inserted into  
their openings on the Faceplate, and the No-Button Trim Ring is securely fastened. Verify the  
No-Button Trim Ring is firmly inserted onto the Faceplate and that there are no gaps between this  
Trim Ring and the outer surface of the Faceplate.  
9. Place the Faceplate back onto the main NXD-CV5 unit. Make sure to align the Microphone, Light,  
and PIR Motion sensor locations on the main unit to their respective openings on the Faceplate  
assembly.  
14  
5" Modero Widescreen Touch Panel  
   
Installation  
Installing the Button Trim Ring  
The outer No-Button Trim Ring is secured to the Faceplate with plastic latches. In order to re-install the  
Button Trim Ring back onto an NXD panel which has had the default Button Trim Ring features  
removed; you must first remove the No-Button Trim Ring:  
1. To remove the Faceplate, simply pull it away from the panel by gently tugging it outwards until the  
entire Faceplate comes away from the panel.  
2. Turn the Faceplate over to expose the inside surface and view the Trim Ring latches.  
3. In a single motion, press down and then outwards on the two Trim Ring latches located along the  
top of the internal surface of the Faceplate to begin removing the Trim Ring. Removing the Internal  
Faceplate from the panel exposes the pushbuttons openings left from an earlier removal of the  
pushbuttons.  
4. Gently tug along the edges of the No-Button Trim Ring and work your way around the edges to  
remove it from the Faceplate (FIG. 12).  
CV5 Panel/enclosure  
Button latch  
Trim  
Ring  
Latches  
Button installation  
(showing the internal surface of Faceplate)  
No-Button Trim Ring  
Faceplate  
(outside surface shown)  
FIG. 12 Removing the No-Button Trim Ring  
5. From along the internal surface of the Faceplate, install the six buttons by firmly inserting them into  
the button openings until the Button latch secures the button in place (FIG. 12).  
6. Grasp the Button Trim Ring on both sides and fit it into the groove along the outside surface of the  
Faceplate (made available by the removal of the previous Trim Ring).  
7. Gently insert the Button Trim Ring latches into their corresponding openings on the outer surface of  
the internal Faceplate (FIG. 13).  
8. Firmly press down around the Button Trim Ring until all of the latches are securely inserted into  
their openings on the Faceplate, and the Button Trim Ring is securely fastened. Verify the Button  
Trim Ring is firmly inserted onto the Faceplate and that there are no gaps between this Trim Ring  
and the outer surface of the Faceplate.  
9. Place the Faceplate back onto the main NXD-CV5 unit. Make sure to align the Microphone, Light,  
and PIR Motion sensor locations on the main unit to their respective openings on the Faceplate  
assembly.  
15  
5" Modero Widescreen Touch Panel  
   
Installation  
Button Trim Ring  
Faceplate (outer surface shown)  
Button openings  
FIG. 13 Inserting the Button Trim Ring  
Installing the Optional NXA-BEZ Colored Trim Ring Kits  
The Bezel Trim Ring Kits allow a user to change to both the color of the faceplate and determine  
whether the panel will or will not use colored pushbuttons. Each grouping has been configured so that  
the accompanying Faceplate, Trim Ring, and pushbuttons are color matched.  
The following table outlines the two different Trim Ring Kits:  
NXA-BEZ Trim Ring Kits (CV5)  
NXA-BEZ-5B Trim Ring Kits  
(with button openings)  
• NXA-BEZ-5B-BG, Beige Faceplate with beige buttons (FG2261-32)  
- Two Beige Faceplates/Bezels  
- Two Beige Button Trim RIngs  
- Two Self-adhesive AMX labels  
- 12 Beige Pushbuttons (2 sets of 6)  
• NXA-BEZ-5B-BL, Black Faceplate with black buttons (FG2261-30)  
- Two Black Faceplates/Bezels  
- Two Black Button Trim RIngs  
- Two Self-adhesive AMX labels  
- 12 Black Pushbuttons (2 sets of 6)  
• NXA-BEZ-5B-LA, Light Almond Faceplate with light almond buttons  
(FG2261-33)  
- Two Almond Faceplates/Bezels  
- Two Almond Button Trim RIngs  
- Two Self-adhesive AMX labels  
- 12 Almond Pushbuttons (2 sets of 6)  
• NXA-BEZ-5B-WH, White Faceplate with white buttons (FG2261-31)  
- Two Almond Faceplates/Bezels  
- Two Almond Button Trim RIngs  
- Two Self-adhesive AMX labels  
- 12 Almond Pushbuttons (2 sets of 6)  
16  
5" Modero Widescreen Touch Panel  
   
Installation  
NXA-BEZ Trim Ring Kits (CV5) (Cont.)  
NXA-BEZ-5NB Trim Ring Kits • NXA-BEZ-5NB-BG, Beige Faceplate without buttons (FG2261-42)  
(without button openings)  
- Two Beige Faceplates/Bezels  
- Two Beige No-Button Trim RIngs  
- Two Self-adhesive AMX labels  
• NXA-BEZ-5NB-BL, Black Faceplate without buttons (FG2261-40)  
- Two Black Faceplates/Bezels  
- Two Black No-Button Trim RIngs  
- Two Self-adhesive AMX labels  
• NXA-BEZ-5NB-LA, Light Almond Faceplate without buttons (FG2261-43)  
- Two Almond Faceplates/Bezels  
- Two Almond No-Button Trim RIngs  
- Two Self-adhesive AMX labels  
• NXA-BEZ-5NB-WH, White Faceplate without buttons (FG2261-41)  
- Two White Faceplates/Bezels  
- Two White No-Button Trim RIngs  
- Two Self-adhesive AMX labels  
FIG. 14 provides an example of the general contents for each of the two types of Bezel Kit  
configurations (Button and No-Button).  
NXA-BEZ-5B With Buttons  
NXA-BEZ-5NB Without Buttons  
(2 sets)  
(2 sets)  
(2 sets)  
(2 sets)  
- 2 Colored Faceplate/Bezels  
- 2 Colored Button Trim Rings  
- 2 Self-adhesive AMX labels  
- 12 Colored Pushbuttons (2 sets of 6)  
- 2 Colored Faceplate/Bezels  
- 2 Colored No-Button Trim Rings  
- 2 Self-adhesive AMX labels  
FIG. 14 Trim Ring Kit Contents (Button and No-Button configurations shown)  
These Bezel Kits require some assembly prior to installation onto the panel. Once assembled, the pre-  
existing Faceplate can be removed and upgraded by using the following these steps.  
1. To remove the current Faceplate, simply pull it away from the panel by gently tugging it outwards  
until the entire Faceplate comes away from the panel.  
2. Use the above table to determine which of the optional Trim Rings Kits will be used.  
17  
5" Modero Widescreen Touch Panel  
 
Installation  
3. Assemble the Kit components:  
To assemble the Bezel Kit with Buttons (FIG. 15):  
CV5 Panel/enclosure  
Button latch  
Trim  
Ring  
Latches  
Button installation  
(showing the internal surface of Faceplate)  
Colored Button Trim Ring  
Colored Faceplate  
(outside surface shown)  
FIG. 15 Installing the Button Bezel Kit (NXA-BEZ-5B)  
From along the internal surface of the colored Faceplate, install the six colored buttons  
by firmly inserting them into the button openings until the Button latch secures the button  
in place (FIG. 15).  
Grasp the provided Button Trim Ring on both sides and fit it into the groove along the  
outside surface of the Faceplate.  
Gently insert the Button Trim Ring latches into their corresponding openings on the outer  
surface of the internal Faceplate (FIG. 15).  
Firmly press down around the Button Trim Ring until all of the latches are securely  
inserted into their openings on the Faceplate, and the Button Trim Ring is securely  
fastened. Verify the Button Trim Ring is firmly inserted onto the Faceplate and that there  
are no gaps between this Trim Ring and the outer surface of the Faceplate.  
Continue on to Step 4 to complete the installation process.  
To assemble the Bezel Kit with No-Buttons (FIG. 16):  
Grasp the provided No-Button Trim Ring on both sides and fit it into the groove along  
the outside surface of the Faceplate.  
Firmly press down around the No-Button Trim Ring until all of the latches are securely  
inserted into their openings on the Faceplate, and the Trim Ring is securely fastened.  
Verify the No-Button Trim Ring is firmly inserted onto the Faceplate and that there are  
no gaps between this Trim Ring and the outer surface of the Faceplate.  
Continue on to Step 4 to complete the installation process.  
4. Place that new Faceplate onto the main NXD-CV5 unit. Make sure to align the Microphone, Light,  
and PIR Motion sensor locations on the main unit to their respective openings on the Faceplate  
assembly.  
18  
5" Modero Widescreen Touch Panel  
 
Installation  
No-Button Trim Ring  
Hollow button openings  
Faceplate (outer surface shown)  
FIG. 16 Installing the No-Button Bezel Kit (NXA-BEZ-5NB)  
Pre-Wall Installation of the Rough-In Box  
Wall Mount panels (NXDs) are contained within an outer housing (back box). This back box is not  
removed when installing the NXD into a CB-TP5 Rough-In Box. The back box is only removed to gain  
access for the replacement of the internal components.  
INSTALLER: LEAVE A GAP BETWEEN THE STUD AND ROUGH-IN BOX  
MOUNTING TABS TO ACCOMMODATE THE DRYWALL or SHEETROCK.  
This gap allows the installation of the drywall or sheetrock after the CB-TP5 Rough-In  
Box has been installed.  
The CB-TP5 is an optional metallic box that is secured onto a stud/beam in a pre-wall setting (where no  
walls are present). Installation procedures and configurations can vary depending on the installation  
environment. This section describes the installation procedures for the most common installation  
scenario. The most important thing to remember when mounting this rough-in box is that the NXD-CV5  
Mounting Tabs must lie flush against the outside of the sheetrock (FIG. 17).  
Refer to SP-2261-01 for detailed installation dimensions.  
It is recommended that you cut out the surface slightly smaller than what is outlined in the  
installation drawings so that you can make any necessary cutout adjustments.  
The wiring knockouts on the left side will be used for the NXD-CV5 Wall Mount panel  
connectors, so always secure the rough-in box to the stud using the Stud Mounting Holes on  
the right side of the box.  
1. Rest the right Stud Mounting tabs onto the stud (keeping the knockouts on the left). Be sure to  
leave enough of a gap between the stud and NXD Mounting tabs to accommodate the  
installation of the drywall or sheetrock after the rough-in box has been mounted. Ultimately,  
the Mounting Tabs should lie flush against the outside of the sheetrock.  
2. Fasten the CB-TP5 rough-in box to the stud through the holes on the right Stud Mounting tabs  
(FIG. 17), using either nails or screws.  
3. Remove the wiring knockouts from the left side of the rough-in box (CB-TP5) (FIG. 17) to  
accommodate the cables being threaded through to the NXD touch panel.  
19  
5" Modero Widescreen Touch Panel  
   
Installation  
Stud Mounting tabs  
Stud  
Wiring  
knockouts (6)  
(must be  
located on  
left side)  
NXD Mounting tabs  
(should lie flush against  
the outside of the wall)  
Drywall or sheetrock  
FIG. 17 CB-TP5 rough-in box components  
Remember that when mounting this rough-in box, the NXD mounting tabs must lie  
flush against the outside of the sheetrock.  
4. Thread the incoming power, RJ-45 audio/video, Ethernet, and USB wiring through the knockouts  
(use of the left wiring knockouts are recommended with this installation).  
Leave enough slack in the wiring to accommodate any re-positioning of the panel.  
5. Install the drywall/sheetrock before inserting the main NXD unit into the CB-TP5.  
Installation of an NXD Touch Panel  
The NXD-CV5 can be installed either directly into the (optional) CB-TP5 or other solid surface  
environment using the two different mounting options: drywall clips or solid surface screws. The  
following sections describe mounting the touch panel directly into a pre-wall rough-in box, a solid  
surface or drywall, and optional NXA-RK5 Rack Mount Kit.  
Installing the NXD panel within a Rough-In Box  
The rough-in box must be mounted prior to continuing this section. Refer to the procedures in the  
instructions. Verify that all necessary cables have been threaded through the knockouts on the left of the  
rough-in box and the connections have been tested prior to installation of the NXD-CV5.  
1. Remove the Faceplate/bezel (A in FIG. 18) from the main NXD unit (B in FIG. 18) by gripping the  
faceplate and pulling with gentle outward force.  
2. Verify the incoming power, RJ-45 audio/video, Ethernet, and USB cables have been properly  
threaded through the wiring knockouts on the left of the rough-in box. Leave enough slack in the  
wiring to accommodate any re-positioning of the panel.  
20  
5" Modero Widescreen Touch Panel  
     
Installation  
C - Optional CB-TP5  
Stud  
rough-in/wallbox  
#4-40 Mounting Screws  
(three - included)  
secure the NXD to  
the Rough-In Box  
Mounting Tab  
B - Main NXD unit consists of  
the touch panel and back box housing  
A - Faceplate/Trim Ring  
default Faceplate comes with buttons  
FIG. 18 NXD-CV5 panel installation into a CB-TP5 (pre-wall construction)  
3. Connect all data and power wiring connectors to their corresponding locations along the side of the  
(un-powered) NXD touch panel.  
Verify that the terminal end of the power cable is not connected to a power source before  
plugging in the 2-pin power connector.  
The USB connectors can be from either a USB extension cable, or a wireless USB RF  
transmitter.  
4. Test the incoming wiring by connecting the panel connections to their terminal locations and  
applying power. Verify that the panel is receiving power and functioning properly to prevent  
repetition of the installation.  
5. Disconnect the terminal end of the power cable from the connected power supply.  
Don’t disconnect the connectors from the touch panel. The unit must be installed with  
the attached connectors before being inserted into the rough-in box.  
6. Carefully slide the main NXD-CV5 unit (B in FIG. 18) into the rough-in box, so that all Mounting  
Tabs lie flush against the rough-in box (C in FIG. 18).  
7. Insert and secure three #4-40 Mounting Screws (included) into their corresponding holes located  
along the sides of the NXD.  
8. Place the Faceplate/Trim Ring (A in FIG. 18) back onto the main NXD unit (B in FIG. 18).  
Make sure to align the Microphone, Light, and PIR Motion sensor locations to their respective  
openings on the front faceplate/bezel.  
9. Reconnect the terminal RJ-45, Ethernet, USB, and any optional audio/video wiring to their  
respective locations (outside the rough-in box) on either the NXA-AVB/ETHERNET Breakout Box,  
Ethernet port, or NetLinx Master.  
21  
5" Modero Widescreen Touch Panel  
 
Installation  
10. Reconnect the terminal power connector on the 12 VDC-compliant power supply and apply power.  
Installing the NXD into drywall using Expansion Clips  
Expansion clips are mounted through the three oval holes located along the rim of the NXD-CV5. As the  
screw is tightened, the clip bends toward the insertion hole and into the wall. This bending creates a  
"grip" on the wall by either pressing onto the wall or by securing the drywall between the housing and  
the drywall clip.  
The most important thing to remember when mounting the NXD is that the outer frame (Mounting Tabs)  
must be installed flush against the mounting surface.  
Refer to SP-2261-02 for detailed installation dimensions (reproduced in FIG. 19).  
It is recommended that you cutout the surface slightly smaller than what is outlined in the  
installation drawings so that you can make any necessary cutout adjustments.  
1. Prepare the area by removing any screws or nails from the drywall before beginning the cutout  
process.  
2. Cut out the surface for the NXD Wall Mount unit.  
If installing the panel into a pre-existing wall or surface, place and secure the pre-printed  
Mounting Template for Flush Mount Drywall Installation (62-2261-10) onto the surface.  
Trace the required cutout along the drywall. Refer to the dimensions in FIG. 19 for more  
information.  
It is recommended that the actual cutout opening be slightly smaller than the  
provided dimensions. This action provides the installer with a margin for error if the  
opening needs to later be expanded.  
Be sure to cut out the three notches along the sides to accommodate the three  
corresponding drywall expansion clips (included within the Installation Kit).  
3. Remove the Faceplate/bezel (A in FIG. 20) from the main NXD unit (B in FIG. 20) by gripping the  
faceplate and pulling with gentle outward force.  
4. Thread the incoming power, RJ-45, Ethernet, USB, and any optional audio/video wiring (from their  
terminal locations) through the surface opening. Leave enough slack in the wiring to accommodate  
any re-positioning of the panel.  
5. Connect all data and power wiring connectors to their corresponding locations along the left side of  
the (un-powered) NXD touch panel.  
Verify that the terminal end of the power cable is not connected to a power source before  
plugging in the 2-pin power connector.  
The USB connectors can be from a either a USB extension cable, or a wireless USB RF  
transmitter.  
22  
5" Modero Widescreen Touch Panel  
 
Installation  
FIG. 19 NXD-CV5 Wall Mount panel dimensions using expansion clips  
6. Test the incoming wiring by attaching the panel connections to their terminal locations and applying  
power. Verify the panel is receiving power and functioning properly to prevent repetition of the  
installation.  
7. Disconnect the terminal end of the power cable from the connected power supply.  
23  
5" Modero Widescreen Touch Panel  
 
Installation  
3 notches are  
required to  
accommodate the  
three expansion  
clips (included)  
Install the 3 included  
drywall clip sets  
into these locations  
Drywall Clip (3)  
Mounting Tab  
B - Main NXD unit consists of  
the touch panel and back box  
A - Faceplate  
/Trim Ring  
FIG. 20 Wall Mount panel (NXD) installation configuration for drywall surfaces  
Don’t disconnect the connectors from the touch panel. The unit must be installed with  
the attached connectors before being inserted into the drywall.  
8. Install the three sets of drywall screws and expansion clips into the three oval notch locations along  
both sides of the main unit (B in FIG. 20).  
9. Carefully insert the main unit (with expansion clips) into the cutout until the Mounting Tabs on the  
NXD unit lie flush against the wall.  
The drywall clip set must be re-ordered from AMX if the drywall clip is bent  
accidentally during an installation or removed during a re-installation.  
10. Tighten all three drywall clip sets (screws and clips) until the entire Mounting Tab is securely  
fastened and flush against the wall.  
11. Place the Faceplate/Trim Ring assembly (A in FIG. 20) back onto the main NXD unit  
(B in FIG. 20). Make sure to align the Microphone, Light, and PIR Motion sensor locations to their  
respective openings on the front faceplate/bezel.  
12. Reconnect the terminal RJ-45, Ethernet, USB, and any optional audio/video wiring to their  
respective locations on either the NXA-AVB/ETHERNET Breakout Box, Ethernet port, or NetLinx  
Master.  
13. Reconnect the terminal power connector on the 12 VDC-compliant power supply and apply power.  
24  
5" Modero Widescreen Touch Panel  
 
Installation  
Installing the NXD into a Flat Surface using #4 screws  
Mounting screws (#4, not included) are secured through circular holes located at the left and right sides  
of the NXD-CV5. The most important thing to remember when mounting the NXD is that the outer  
frame (Mounting Tabs) must be installed flush against the mounting surface.  
Refer to SP-2261-02 for detailed installation dimensions (reproduced in FIG. 21).  
It is recommended that you cutout the surface slightly smaller than what is outlined in the  
installation drawings so that you can make any necessary cutout adjustments.  
1. Prepare the area by removing any screws or nails from the surface before beginning the cutout  
process.  
2. Cut out the surface for the NXD Wall Mount unit using the dimensions shown in FIG. 21.  
FIG. 21 NXD-CV5 Wall Mount panel dimensions using #4 mounting screws  
3. Remove the Faceplate/bezel (A in FIG. 22) from the main NXD unit (B in FIG. 22) by gripping the  
faceplate and pulling with gentle outward force.  
4. Thread the incoming power, RJ-45, Ethernet, USB, and any optional audio/video wiring (from their  
terminal sources) through the surface opening. Leave enough slack in the wiring to accommodate  
any re-positioning of the panel.  
25  
5" Modero Widescreen Touch Panel  
   
Installation  
5. Connect all data and power wiring connectors to their corresponding locations along the left side of  
the (un-powered) NXD touch panel.  
Verify that the terminal end of the power cable is not connected to a power source before  
plugging in the 2-pin power connector.  
The USB connectors can be from a either a USB extension cable, or a wireless USB RF  
transmitter.  
6. Test the incoming wiring by connecting the panel connections to their terminal locations and  
applying power. Verify that the panel is receiving power and functioning properly before finalizing  
the installation.  
Attachment is done  
along the edges  
of the cutout  
Flat installation surface  
Install the three #4 Mounting Screws  
(not included) into these three holes  
(suggested length of screws is 0.25")  
Mounting Tab  
B - Main CV5 unit  
A - Faceplate/Trim Ring  
FIG. 22 Wall Mount panel installation configuration for flat surfaces  
7. Disconnect the terminal end of the power cable from the power supply.  
Don’t disconnect the connectors from the touch panel. The unit must be installed with  
the necessary connectors before being inserted into the solid surface.  
8. Carefully slide the main unit into the cutout until the Mounting Tabs of the CV5 unit lie flush  
against the wall.  
9. Insert and secure three #4 Mounting Screws (not included) into their corresponding holes located  
along the sides of the NXD-CV5 (using a grounded Phillips-head screwdriver) until the unit is  
secure and flush against the wall (FIG. 22).  
26  
5" Modero Widescreen Touch Panel  
 
Installation  
10. Place the Faceplate/Trim Ring assembly (A in FIG. 22) back onto the main NXD unit  
(B in FIG. 22). Make sure to align the Microphone, Light, and PIR Motion sensor locations to their  
respective openings on the front bezel/faceplate.  
11. Reconnect the terminal RJ-45, Ethernet, USB, and any optional audio/video wiring to their  
respective locations on either the NXA-AVB/ETHERNET Breakout Box, Ethernet port, or NetLinx  
Master.  
12. Reconnect the terminal power connector on the 12 VDC-compliant power supply and apply power.  
Installing an NXD-CV5 into a Rack Mount Kit (NXA-RK5)  
The NXA-RK5 is a 19" (48.26 cm) wide metal rack-mount (with black matte finish) measuring  
3 rack units high.  
1. Remove the Faceplate/Trim Ring assembly from the main CV5 unit.  
2. Thread the incoming power, RJ-45 audio/video, Ethernet, and USB wiring (from their terminal  
sources) through the surface opening, leaving enough slack in the wiring to accommodate any  
re-positioning of the panel.  
3. Connect all data and power wiring connectors to their corresponding locations along the left side of  
the (un-powered) NXD touch panel.  
Verify that the terminal end of the power cable is not connected to the a power supply before  
plugging in the 2-pin power connector.  
The USB connectors can be from a either a USB extension cable, or a wireless USB RF  
transmitter.  
4. Test the incoming wiring by connecting the panel connections to their terminal locations and  
applying power. Verify that the panel is receiving power and functioning properly to prevent  
repetition of the installation.  
5. Disconnect the terminal end of the power cable from the connected power supply.  
Don’t disconnect the connectors from the touch panel. The unit must be installed with  
the necessary connectors before being inserted into the equipment rack.  
6. Carefully insert the CV5 panel into the NXA-RK5.  
7. Secure the panel to the NXA-RK5 mount by first inserting and then tightening the three #4-40  
screws (included).  
8. Insert the NXA-RK5 (with connected NXD unit) into the equipment rack, making sure to align the  
screw holes along the sides on the NXA-RK5 with the holes in the equipment rack.  
9. Use a grounded Phillips-head screwdriver to secure the NXA-RK5 to the equipment rack using the  
#10-32 screws (included).  
10. Place the Faceplate/Trim Ring assembly back onto the main NXD unit. Make sure to align the  
Microphone, Light, and PIR Motion sensor locations to their respective openings on the front  
faceplate/bezel.  
11. Reconnect the terminal RJ-45 audio/video, Ethernet, and USB wiring to their respective terminal  
locations on either the NXA-AVB/ETHERNET Breakout Box, Ethernet port, or NetLinx Master.  
12. Reconnect the terminal power connector on the 12 VDC-compliant power supply and apply power.  
27  
5" Modero Widescreen Touch Panel  
 
Installation  
Wiring Guidelines for the CV5 Panels  
The CV5 panel uses a 12 VDC-compliant power supply to provide power to the panel via the  
2-pin 3.5 mm mini-Phoenix PWR connector. Use the power requirements information (page 2) to  
determine the power draw.  
The incoming PWR and GND wires from the power supply must be connected to the corresponding  
locations within the PWR connector.  
This unit should only have one source of incoming power.  
Using more than source of power to the panel can result in damage to the internal  
components and a possible burn out.  
Apply power to the panels only after installation is complete.  
Preparing captive wires  
You will need a wire stripper and flat-blade screwdriver to prepare and connect the captive wires.  
Never pre-tin wires for compression-type connections.  
1. Strip 0.25 inch (6.35 mm) of insulation off all wires.  
2. Insert each wire into the appropriate opening on the connector (according to the wiring diagrams  
and connector types described in this section).  
3. Tighten the screws to secure the wire in the connector. Do not tighten the screws excessively; doing  
so may strip the threads and damage the connector.  
Wiring a power connection  
To use the 2-pin 3.5 mm mini-Phoenix connector with a 12 VDC-compliant power supply, the incoming  
PWR and GND wires from the external source must be connected to their corresponding locations on the  
connector (FIG. 23).  
1. Insert the PWR and GND wires on the terminal end of the 2-pin 3.5 mm mini-Phoenix cable.  
Match the wiring locations of the +/- on both the power supply and the terminal connector.  
2. Tighten the clamp to secure the two wires. Do not tighten the screws excessively; doing so may strip  
the threads and damage the connector.  
3. Verify the connection of the 2-pin 3.5 mm mini-Phoenix to the external 12 VDC-compliant power  
supply.  
PWR +  
Power Supply  
GND -  
To the Touch Panel  
FIG. 23 NetLinx power connector wiring diagram  
28  
5" Modero Widescreen Touch Panel  
       
Installation  
Audio/Video Port: Connections and Wiring  
The following table shows the signal and pinout/pairing information used on the RJ-45 Audio and Video  
connections.  
Audio/Video RJ-45 Pinout Information  
Pin  
1
Wire Color  
Orange/White  
Orange  
Function  
Right Audio In  
Right Audio In  
Video In  
Polarity  
+
-
2
3
Green/White  
Blue  
-
4
Mic Out  
-
5
White/Blue  
Green  
Mic Out  
+
+
+
-
6
Video In  
7
White/Brown  
Brown  
Left Audio In  
Left Audio In  
TIA 568B  
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
(female)  
(male)  
RJ-45 connector - pin configurations  
Ethernet/RJ-45 Port: Connections and Wiring  
FIG. 24 describes the blink activity for the Ethernet 10/100 Base-T RJ-45 connector and cable. The  
Ethernet cable is connected to the side of the Wall Mount panels.  
A - Activity LED (yellow)  
lights when receiving or  
transmitting Ethernet  
data packets  
L - Link LED (green) lights when  
the Ethernet cables are connected  
and terminated correctly.  
A
L
ETHERNET  
10/100  
FIG. 24 Ethernet connector (showing communication and connection LEDs)  
The following table lists the pinouts, signals, and pairing for the Ethernet connector.  
Ethernet RJ-45 Pinouts and Signals  
1 2 3 4 5 6 7 8  
Pin  
1
Signals  
TX +  
Connections Pairing  
Color  
1 --------- 1  
2 --------- 2  
3 --------- 3  
4 --------- 4  
5 --------- 5  
6 --------- 6  
7 --------- 7  
8 --------- 8  
1 --------- 2  
3 --------- 6  
4 --------- 5  
7 --------- 8  
Orange-White  
Orange  
2
TX -  
3
RX +  
Green-White  
Blue  
4
no connection  
no connection  
RX -  
5
Blue-White  
Green  
6
7
no connection  
no connection  
Brown-White  
Brown  
1 2 3 4 5 6 7 8  
8
29  
5" Modero Widescreen Touch Panel  
     
Installation  
FIG. 25 diagrams the RJ-45 pinouts and signals for the Ethernet RJ-45 connector and cable.  
FIG. 25 RJ-45 wiring diagram  
USB Port: Connecting and Using Input Devices  
The CV5 panel can have up to two USB-capable input devices connected for use on its different  
firmware and TPD4 panel pages. These input devices can consist of a keyboard or mouse.  
USB-connected input devices are not detected and recognized by the panel until  
power is cycled to the unit.  
A mini-USB connection is only detected after it is installed onto an active  
panel. Connection to a previously powered panel, allows the PC to detect the  
panel and assign an appropriate USB driver.  
1. Insert the input device USB connectors into the appropriate USB connector on the panel.  
2. Press the on-screen Reboot button from the Protected Setup page to save any changes and restart  
the panel.  
3. After the panel splash-screen disappears:  
If a USB mouse has been connected, a mouse cursor appears on the panel screen and its  
location corresponds to the mouse cursor position sent by the external USB mouse.  
If a USB keyboard has been connected, only on-screen keyboards and keypads will reflect any  
external keystrokes sent from the external USB keyboard.  
30  
5" Modero Widescreen Touch Panel  
   
Panel Calibration  
Panel Calibration  
This section outlines the steps for calibrating the touch panel. It is recommended that you calibrate the  
panel before its initial use and after completing a firmware download.  
Modero panels are factory setup with specific demo touch panel pages. The first splash screen that  
appears indicates the panel is receiving power, beginning to load firmware, and preparing to display the  
default touch panel pages. When the panel is ready, the AMX Splash Screen is replaced by the Initial  
Panel Page (FIG. 26).  
AMX Splash Screen  
(appears during power-up)  
Initial Panel Page  
(AMX Logo Page)  
FIG. 26 AMX splash screen and initial Panel Page  
Calibrating the Modero Panel  
1. Press and hold the grey Front Setup Access button (FIG. 27) for 6 seconds to pass-over the Setup  
page and access the Calibration setup page (FIG. 28).  
Front Setup  
Access button (grey)  
3 second press/hold:  
Opens the Setup page  
6 second press/hold:  
Opens the Calibration page  
Single press puts  
the panel to sleep  
FIG. 27 Location of Front Setup Access button  
2. Press the crosshairs (on the Calibration page) to set the calibration points on the LCD (FIG. 28).  
3. After the "Calibration Successful.." message appears, press anywhere on the screen to continue and  
return to the Setup page.  
31  
5" Modero Widescreen Touch Panel  
         
Panel Calibration  
The request to touch the crosshairs  
is the first on-screen message  
Calibration successful is the second  
on-screen message that appears  
after the calibration process is  
completed  
On-screen crosshairs used for  
calibration of the touch device  
FIG. 28 Touch Panel Calibration Screens  
If the calibration was improperly set and you cannot return to the Calibration  
page (through the panel’s firmware); you can then access this firmware page via  
G4 WebControl where you can navigate to the Protected Setup page and press the  
Calibrate button through your VNC window.  
This action causes the panel to go to the Calibration page seen above, where you  
can physically recalibrate the actual touch panel again using the above procedures.  
Testing your Calibration  
1. Press and hold down the on-screen Calibration button for 6 seconds to enter the Calibration Test  
page (FIG. 29).  
On-screen crosshairs is used to  
verify a proper calibration of the  
panel  
FIG. 29 Calibration Test page  
2. Press anywhere on this page to confirm the on-screen crosshairs match your touch points.  
3. If the crosshairs do not appear directly below your LCD touch points, press the Back button and  
recalibrate the panel using the above steps.  
4. Exit this Calibration Test page by pressing the Back button to return to the Protected Setup page.  
32  
5" Modero Widescreen Touch Panel  
     
Configuring Communication  
Configuring Communication  
Communication between the Modero panel and the Master is done using either USB or ETHERNET  
(DHCP or Static IP). Ethernet communication can only be achieved via a direct Ethernet connection  
(the NXA-WC802.11B/CF wireless interface card is not available on the CV5).  
Before commencing, verify you are using the latest NetLinx Master and Modero panel  
firmware. Verify you are using the latest versions of AMX’s NetLinx Studio and  
TPDesign4 programs.  
USB input devices must be plugged into the rear or side USB connectors before the  
G4 panel is powered-up. The panel will not detect a USB connection of this type until  
after the unit cycles power.  
Modero Setup and System Connection  
1. Press the grey Front Setup Access button for 3 seconds to open the Setup page (FIG. 30).  
Connection Status  
Red Connection Status icon -  
indicates no connection  
to a Master  
Green Connection Status icon -  
indicates communication  
to a Master  
FIG. 30 Setup page  
2. Press the Protected Setup button (located on the lower-left of the panel page) to open the Protected  
Setup page and display an on-screen keypad.  
3. Enter 1988 into the Keypad’s password field and press Done when finished.  
Clearing Password #5, from the initial Password Setup page, removes the need for  
you to enter the default password before accessing the Protected Setup page.  
4. Press the red Device Number field to open the Device Number keypad (FIG. 31).  
5. Enter a Device Number for the panel into the Device Number Keypad.  
The default is 10001 and the range is from 1 - 32000.  
When using multiple panels within a NetLinx System, remember to assign unique  
Device Number values to each panel so that all assigned panels appear in the  
System listing for the target Master.  
6. Press Done to close the keypad, assign the number, and return to the Protected Setup page.  
7. Press the on-screen Reboot button to restart the panel and incorporate any changes.  
33  
5" Modero Widescreen Touch Panel  
       
Configuring Communication  
FIG. 31 Protected Setup page  
Before continuing, open NetLinx Studio. This program assists in developing a System  
Number, Master IP/URL, and Master Port number. Refer to your NetLinx Master’s  
instruction manuals for more information.  
8. Obtain the System Number and Master IP Address from NetLinx Studio. This information must be  
specific for the system used with the configured Modero panel.  
9. Press the grey Front Setup Access button for 3 seconds to open the Setup page.  
10. Press the Protected Setup button (located on the lower-left of the panel page) to open the Protected  
Setup page.  
11. Press the System Connection button (located on the Protected Setup page) to open the System  
Connection page (FIG. 32) and begin configuring the communication settings on the panel to match  
those of the target Master.  
Modero  
connection  
information  
NetLinx Master’s  
connection  
information  
MAC Address  
from panel is  
factory set to a  
unique address  
FIG. 32 System Connection page  
There are 2 possible Master Connection Types available: USB or Ethernet.  
A USB connection type is a direct connection from the panel’s mini-USB port to a  
corresponding USB port on the PC (acting as a Virtual Master).  
An Ethernet connection type involves indirect communication from the panel to a  
Master via an Ethernet connection to the network.  
34  
5" Modero Widescreen Touch Panel  
   
Configuring Communication  
It is recommended that firmware KIT files only be transferred over a direct connection  
and only when the panel is connected to a power supply. I  
The mini-USB connector MUST be plugged into an already active panel before the  
PC can recognize the connection and assign an appropriate USB driver. This driver is  
part of both the NetLinx Studio and TPDesign4 software application installations.  
Configuring and Using USB with a Virtual Master  
NetLinx Studio can be setup to run a Virtual Master where the PC acts as the Master by supplying its  
own IP Address for communication to the panel. The PC is first equipped with the USB driver, the panel  
is then configured for USB communication, and then Studio is configured to act as the Master.  
For a personal computer to establish a connection to a Modero panel via USB, the target computer must  
have the appropriate AMX USB driver installed. This installation is bundled into the latest TPDesign4  
software setup process or can be downloaded independently from the main Application Files page on  
www.amx.com.  
Step 1: Setup the Panel and PC for USB Communication  
1. If you do not currently have the latest version of TPDesign4, navigate to www.amx.com > Tech  
Center > Downloadable Files > Application Files > NetLinx Design Tools section of the website  
and locate the AMX USB Driver executable (AMX USBLAN Setup exe).  
2. Download this executable file to a known location on your computer.  
3. Launch the Setup.exe and follow the on-screen prompts to complete the installation.  
Step 2: Confirm the Installation of the USB Driver on the PC  
The first time each AMX touch panel is connected to the PC it is detected as a new hardware device and  
the USBLAN driver becomes associated with it (panel specific). Each time thereafter the panel is  
"recognized" as a unique USBLAN device and the association to the driver is done in the background.  
When the panel is detected for the first time some user intervention is required during the association  
between panel and driver.  
1. After the installation of the USB driver has been completed, confirm the proper installation of the  
large Type-A USB connector to the PC's USB port, and restart your machine.  
If the panel is already powered, continue with steps 3.  
The panel MUST be powered and configured for USB communication before  
connecting the mini-USB connector to the panel’s Program Port.  
2. Connect the terminal end of the 12 VDC-compliant power supply cable to the power connector on  
the rear/side of the touch panel and then apply power.  
3. After the CV5 panel powers-up, press and hold the grey Front Setup Access button (for 3 seconds)  
to continue with the setup process and proceed to the Setup page.  
4. Select Protected Setup > System Connection (located on the lower-left) to open the System  
Connection page (FIG. 33).  
5. Toggle the blue Type field (from the Master Connection section) until the choice cycles to USB.  
Refer to the System Settings Page section on page 74 for more information about the fields on this  
page.  
35  
5" Modero Widescreen Touch Panel  
       
Configuring Communication  
No connection is established until  
the Virtual Master becomes  
active within Studio  
Red Connection Status icon -  
indicates no connection to a Virtual  
Master  
Green Connection Status icon -  
indicates communication to a Virtual  
Master  
FIG. 33 USB System Connection page - using a USB Connection Type  
ALL fields are then greyed-out and read-only, but still display any previous network  
information.  
6. Press the Back button on the touch panel to return to the Protected Setup page.  
7. Press the on-screen Reboot button to both save any changes and restart the panel. Remember that  
the panel’s connection type must be set to USB prior to rebooting the panel and prior to inserting  
the USB connector.  
8. ONLY AFTER the unit displays the first panel page, THEN insert the mini-USB connector into  
the Program Port on the panel. It may take a minute for the panel to detect the new connection and  
send a signal to the PC (indicated by a green System Connection icon). If this is your first time  
installing the USB driver, a USB driver installation popup window (FIG. 34) appears on the PC.  
FIG. 34 USB driver installation popup window  
This window notifies you that the panel has been detected by the PC as a USB-compliant  
device and the PC is installing an appropriate USB driver to establish a proper communication  
to the panel.  
This driver was installed on your PC during the installation of the latest NetLinx Studio and  
TPDesign4 software application installations. These applications should be installed prior  
to setting up a USB connection to the panel.  
36  
5" Modero Widescreen Touch Panel  
   
Configuring Communication  
The driver does not contain a Microsoft® digital signature and Windows® then informs you of  
such.  
9. Click Yes when told that a digital signature was not found. This action accepts the installation of the  
new AMX USB driver. The panel is now configured to communicate directly with the PC.  
This process completes the association between driver and device.  
Each time the same touch panel is connected to the computer the driver is automatically  
loaded (using a unique name - example USB LAN LINK #1, #2).  
Each time a different touch panel is connected to the computer, the previous procedures  
will need to be repeated.  
10. Navigate back to the System Connection page.  
Step 3: Confirm and View the current AMX USB device connections  
The USB driver information can be confirmed via two different methods:  
Via the Control panel (previous steps 1 and 2) or  
Via the Unplug or Eject Hardware icon from the Taskbar.  
1. Navigate to Start > Settings > Control Panel > and double-click the System icon to launch the  
System Properties dialog.  
2. Select the Hardware tab and click on the Device Manager button to launch the Device Manager  
dialog.  
Within the Device Manager dialog, the AMX USBLAN device appears under Network  
Adapters (FIG. 35) and has a unique name such as AMX USB LAN LINK #2. The number  
changes depending on which recognized panel is currently connected.  
USB connected touch  
panel (showing the  
recognized panel)  
FIG. 35 Device Manager dialog showing USB device  
3. Confirm that a new USB detection icon (FIG. 36) appears in the lower-right taskbar on the PC  
display window.  
4. Double-click on the icon to open the Unplug or Eject Hardware window and confirm the AMX  
USB LAN LINK has been installed and is operating properly.  
A Virtual NetLinx Master (VNM) is used when the target panel is not connected to a  
physical NetLinx Master. In this situation, the PC takes on the functions of a Master  
via a Virtual NetLinx Master. This connection is made by either using the PC’s  
Ethernet Address (via TCP/IP using a known PC’s IP Address as the Master) or  
using a direct mini-USB connection to communicate directly to the panel.  
37  
5" Modero Widescreen Touch Panel  
   
Configuring Communication  
5. Click the Properties button to view further information about the installed USB driver.  
USB  
detection  
icon  
FIG. 36 USB Properties windows  
If there is a yellow exclamation point next to the AMX USB LAN LINK device (within  
the hardware devices section of the Unplug or Eject Hardware window), stop and  
close the USB operation. Reconnect the USB cable to the panel and repeat the setup  
procedures. Refer to the Troubleshooting section on page 143 for more detailed  
information.  
To remove the USB driver association from a previously connected touch panel, you must navigate  
back to the Device Manager, right-click on the panel’s USB driver (example AMX USB LAN LINK #2)  
and select Uninstall from the context menu and then OK.  
Once the system completes the removal of the device, the Device Manager window will  
refresh, and the device will no longer appear.  
The next time this device is connected to the computer it will appear as a new hardware device  
and will need to be associated again with the driver (refer to Step 2: Confirm the Installation  
Step 4: Use the USB to Configure a Virtual Master (using NetLinx Studio)  
When configuring your panel to communicate via USB with a Virtual Master (on your  
PC), ONLY the USB connection option must be selected within the Type field. Since  
this is a direct connection, the PC’s IP Address is not needed.  
Before beginning:  
1. Verify the panel has been configured to communicate via USB within the System Connection page  
and that the USB driver has been properly configured. Refer to the previous section for more  
information.  
2. Launch NetLinx Studio 2.x (default location is Start > Programs > AMX Control Disc > NetLinx  
Studio 2 > NetLinx Studio 2).  
3. Select Settings > Master Communication Settings, from the Main menu to open the Master  
Communication Settings dialog (FIG. 37).  
4. Click the Communications Settings button to open the Communications Settings dialog.  
5. Click on the NetLinx Master radio button (from the Platform Selection section) to indicate that you  
are working as a NetLinx Master.  
38  
5" Modero Widescreen Touch Panel  
   
Configuring Communication  
IP Address of computer  
(not needed as this is a direct  
USB connection)  
FIG. 37 Assigning Communication Settings for a Virtual Master  
6. Click on the Virtual Master radio box (from the Transport Connection Option section) to indicate  
you are wanting to configure the PC to communicate directly with a panel. Everything else such as  
the Authentication is greyed-out because you are not going through the Master’s UI.  
7. Click the Edit Settings button (on the Communications Settings dialog) to open the Virtual NetLinx  
Master Settings dialog (FIG. 37).  
8. From within this dialog enter the System number (default is 1).  
9. Click OK three times to close the open dialogs, save your settings, and return to the main NetLinx  
Studio application.  
10. Click the OnLine Tree tab in the Workspace window to view the devices on the Virtual System. The  
default System value is one.  
11. Right-click on the Empty Device Tree/System entry and select Refresh System to re-populate the  
list.  
The panel will not appear as a device below the virtual system number (in the Online Tree tab)  
until both the system number used in step 7 for the VNM is entered into the Master Connection  
section of the System Connection page and the panel is restarted.  
The Connection status turns green after a few seconds to indicate an active USB connection to  
the PC (Virtual Master). No Lock icon is displayed because this USB connection is not  
secured (requiring a username/password).  
If the G4 panel does not appear, refer to the Troubleshooting section on page 143 for  
more information.  
If a few minutes have gone by and the System Connection icon still does not turn green, repeat  
the USB connection and Virtual Master setup procedures (outlined in this section). Refreshing  
the System sends out a request to the panel to respond and completes the communication  
(turning the System Connection icon green).  
39  
5" Modero Widescreen Touch Panel  
 
Configuring Communication  
Step 5: Confirm and View the current AMX USB device connections  
Use the CC-USB Type-A to Mini-B 5-wire programming cable (FG10-5965) to provide communication  
between the mini-USB Program port on the touch panel and the PC. This method of communication is  
used to transfer firmware KIT files and TPD4 touch panel files.  
A mini-USB connection is only detected after it is installed onto an active panel.  
Connection to a previously powered panel which then reboots, allows the PC to  
detect the panel and assign an appropriate USB driver.  
1. Verify this direct USB connection (Type-A on the panel to mini-USB on the panel) is configured  
properly using the steps outlined in the previous two sections.  
2. With the panel already configured for USB communication and the Virtual Master setup within  
NetLinx Studio, its now time to verify the panel is ready to receive files.  
3. Click the OnLine Tree tab in the Workspace window to view the devices on the Virtual System. The  
default System value is one.  
4. Right-click on the System entry (A in FIG. 38) and select Refresh System. This causes a refresh of  
all project systems, establishes a new connection to the Virtual Master, and populates the System list  
with devices on your particular system.  
FIG. 38 Using USB for Virtual Master communication  
Configuring a Wired Ethernet Connection  
It is necessary to tell the panel which Master it should be communicating with. This "pointing to a  
Master" is done via the System Connection page where you configure the IP Address, System Number  
and Username/Password information assigned to the target Master. Until those parameters are  
configured, your Connection Status icon will remain red (indicating there is no current connection to a  
Master).  
40  
5" Modero Widescreen Touch Panel  
     
Configuring Communication  
Step 1: Configure the Panel’s Wired IP Settings  
This panel has only one method of communicating to a target Master over the Internet: Wired (direct  
Ethernet connection) (wireless communication is not available on the CV5). You can only configure the  
connection parameters through the System Connection page. This type of communication can be  
established either via either a Dynamic IP Address (DHCP) or via a pre-reserved Static IP Address  
(typically provided by your System Administrator).  
IP Settings section - Configuring a DHCP Address over Ethernet  
1. Select Protected Setup > System Connection (located on the lower-left) to open the System  
Connection page.  
2. Locate the IP Settings section of this page.  
Even though the Host, Gateway, Primary DNS, Secondary DNS, and Domain fields  
appear on the two separate System Connection and Secondary Connection pages;  
the information populating these fields is identical.  
If the information within one of these fields is altered, the change is reflected on both  
pages within the altered field.  
Example: Domain is altered on Secondary Connection page, the value is then also  
changed within the Domain field of the System Connection page.  
3. Toggle the DHCP/Static field (from the IP Settings section) until the choice cycles to DHCP.  
DHCP will register the unique MAC Address (factory assigned) on the panel and  
once the communication setup process is complete, reserve an IP Address, Subnet  
Mask, and Gateway values from the DHCP Server.  
4. Press the optional Host Name field to open a Keyboard and enter the Host Name information.  
5. Press Done after you are finished assigning the alpha-numeric string of the host name.  
6. Do not alter any of the remaining greyed-out fields in the IP Settings section. Once the panel is  
rebooted, these values are obtained by the unit and displayed in the DNS fields after power-up.  
This information can be found in either the: Workspace- System name > Define  
Device section of your code (that defines the properties for your panel), or in the  
Device Addressing/Network Addresses in the Tools > NetLinx Diagnostics dialog.  
7. Press the Back button to return to the Protected Setup page.  
8. Press the on-screen Reboot button to both save any changes and restart the panel.  
IP Settings section - Configuring a Static IP Address over Ethernet  
1. Select Protected Setup > System Connection (located on the lower-left) to open the System  
Connection page.  
2. Locate the IP Settings section of this page.  
Check with your System Administrator for a pre-reserved Static IP Address assigned  
to the panel. This address must be obtained before Static assignment of the panel  
continues.  
3. Toggle the DHCP/Static field (from the IP Settings section) until the choice cycles to Static.  
4. Press the IP Address field to open a Keyboard and enter the Static IP Address (provided by your  
System Administrator).  
5. Press Done after you are finished entering the IP information.  
41  
5" Modero Widescreen Touch Panel  
     
Configuring Communication  
6. Repeat the same process for the Subnet Mask and Gateway fields.  
7. Press the optional Host Name field to open the Keyboard and enter the Host Name information.  
8. Press Done after you are finished assigning the alpha-numeric string of the host name.  
9. Press the Primary DNS field to open a Keyboard, enter the Primary DNS Address (provided by your  
System Administrator) and press Done when compete. Repeat this process for the Secondary DNS  
field.  
10. Press the Domain field to open a Keyboard, enter the resolvable domain Address (this is provided by  
your System Administrator and equates to a unique Internet name for the panel), and press Done  
when complete.  
11. Navigate to the Master Connection section of this page to begin configuring the communication  
parameters for the target Master.  
Step 2: Choose a Master Connection Mode Setting  
There are three Ethernet MODE settings used in the Master Connection section of the System  
Connection page. URL is the most common method.  
Master Connection MODE options:  
URL (Uniform Resource Locator) is the address that defines the route to a file on the Web or  
any other Internet facility.  
In this system, the panel acts as a "Client" and the Master acts as a Server (in that Clients attach  
to it).  
LISTEN sets the Modero panel to "listen" for broadcasts from the Master (using the panel IP from  
its URL list). In this system, the panel acts as a "Server" (in that Clients attach to it) and the Master  
acts as a "Client".  
AUTO is used to instruct the Modero to search for a Master that uses the same System Number  
(assigned within the Master Connection section) and resides on the same Subnet as itself. In this  
case, the Master has its UDP feature enabled.  
This UDP (User Datagram Protocol) is a protocol within the TCP/IP protocol suite that is used in  
place of TCP when a reliable delivery is not required.  
This UDP enabling is done through a Telnet session on the Master. Refer to the particular NetLinx  
Master manual for more detailed information.  
Step 3: Configure an Ethernet Connection Type  
When using Ethernet as your communication method, the NetLinx Master must first  
be setup with either a Static IP or DHCP Address obtained from either NetLinx Studio  
or your System Administrator.  
Before beginning:  
1. Verify the panel has been configured to communicate through an Ethernet cable (connected from  
either the panel to a valid Ethernet Hub).  
Before commencing, verify you are using the latest NetLinx Master firmware.  
2. Verify that the NetLinx Master is receiving power and is communicating via an Ethernet connection  
with the PC running NetLinx Studio.  
3. Connect the terminal end of the 12 VDC-compliant power supply cable to the power connector on  
the rear/side of the touch panel.  
42  
5" Modero Widescreen Touch Panel  
   
Configuring Communication  
4. Verify the green Ethernet LED (from the rear Ethernet port on the Master) is illuminated (indicating  
a proper connection).  
5. Verify the yellow LED (from the rear Ethernet port on the Master) is blinking (indicating  
communication).  
6. After the panel powers-up, press and hold the grey Front Setup Access button (for 3 seconds) to  
proceed to the Setup page.  
7. Select Protected Setup > System Connection (located on the lower-left) to open the System  
Connection page (FIG. 39).  
Obtained  
from  
NetLinx  
Master  
FIG. 39 System Connection page  
Master Connection section - Virtual Master communication over Ethernet  
When configuring your panel to communicate with a Virtual Master (on your PC) via  
Ethernet, the Master IP/URL field must be configured to match the IP Address of the  
PC and make sure to use the Virtual System value assigned to the Virtual Master  
within NetLinx Studio.  
Before beginning:  
1. Verify the panel has been configured to communicate through an Ethernet cable (connected from  
either the panel to a valid Ethernet Hub).  
2. Launch NetLinx Studio 2.x (default location is Start > Programs > AMX Control Disc > NetLinx  
Studio 2 > NetLinx Studio 2).  
3. Select Settings > Master Communication Settings, from the Main menu to open the Master  
Communication Settings dialog (FIG. 40).  
4. Click the Communications Settings button to open the Communications Settings dialog.  
5. Click on the NetLinx Master radio button (from the Platform Selection section) to indicate that you  
are working as a NetLinx Master.  
6. Click on the Virtual Master radio box (from the Transport Connection Option section) to indicate  
you are wanting to configure the PC to communicate with a panel. Everything else such as the  
Authentication is greyed-out because you are not going through the Master’s UI.  
7. Click the Edit Settings button (on the Communications Settings dialog) to open the Virtual NetLinx  
Master Settings dialog (FIG. 40).  
43  
5" Modero Widescreen Touch Panel  
   
Configuring Communication  
Enter this IP  
into the  
Master IP/URL  
field on the  
System Settings  
page  
IP Addresses of computer  
(also obtained by using the  
Start > Run > cmd command)  
FIG. 40 Assigning Communication Settings and TCP/IP Settings for a Virtual Master  
8. From within this dialog enter the System number (default is 1) and note the IP Address of the target  
PC being used as the Virtual Master. This IP Address can also be obtained by following these  
procedures:  
On your PC, click Start > Run to open the Run dialog.  
Enter cmd into the Open field and click OK to open the command DOS prompt.  
From the C:\> command line, enter ipconfig to display the IP Address of the PC. This  
information is entered into the Master IP/URL field on the panel.  
9. Click OK three times to close the open dialogs, save your settings, and return to the main NetLinx  
Studio application.  
10. Click the OnLine Tree tab in the Workspace window to view the devices on the Virtual System.  
The default System value is one.  
11. Right-click on the Empty Device Tree/System entry and select Refresh System to re-populate the  
list.  
12. Power-up your panel and press and hold the grey Front Setup Access button (for 3 seconds) to  
continue with the setup process and proceed to the Setup page.  
13. Select Protected Setup > System Connection (located on the lower-left) to open the System  
Connection page (FIG. 41).  
The System Number is  
assigned to the Master  
within the AMX  
software application  
(these must match)  
Enter the IP Address  
information of the PC  
used as a Virtual  
Master  
When using a Virtual Master,  
there is no need to enter a  
username and/or password  
FIG. 41 Sample System Connection page (for Virtual Master communication)  
44  
5" Modero Widescreen Touch Panel  
   
Configuring Communication  
14. Press the blue Type field (from the Master Connection section) until the choice cycles to the word  
Ethernet.  
15. Press the Mode field until the choice cycles to the word URL.  
By selecting URL, the System Number field becomes read-only (grey) because the panel pulls  
this value directly from the communicating target Master (virtual or not). A Virtual Master  
system value can be set within the active AMX software applications such as: NetLinx Studio,  
TPD4, or IREdit.  
16. Press the Master IP/URL field to open a Keyboard and enter the IP Address of the PC used as the  
Virtual Master.  
17. Click Done to accept the new value and return to the System Connection page.  
18. Do not alter the Master Port Number value (this is the default value used by NetLinx).  
19. Press the Back button to open the Protected Setup page.  
20. Press the on-screen Reboot button to both save any changes and restart the panel.  
Master Connection section - NetLinx Master Ethernet IP Address - URL Mode  
In this mode, enter the System Number (zero for an unknown System Number) and the IP/URL of the  
Master (Master Port Number is defaulted to 1319).  
1. Press the blue Type field (from the Master Connection section) until the choice cycles to the word  
Ethernet (FIG. 41). Refer to the System Settings Page section on page 74 for more information  
about the fields on this page.  
2. Press the Mode field until the choice cycles to the word URL.  
By selecting URL, the System Number field becomes read-only (grey) because the panel pulls  
this value directly from the communicating target Master (virtual or not). A Virtual Master  
system value can be set within the active AMX software applications such as: NetLinx Studio,  
TPD4, or IREdit.  
If the panel does not appear within the OnLine Tree tab of the Workspace window of  
NetLinx Studio, check to make sure that the NetLinx Master System Number (from  
within the Device Addressing dialog) is correctly assigned.  
3. Press the Master IP/URL field to open a Keyboard and enter the Master IP Address (obtained from  
the Diagnostics - Networking Address dialog of the NetLinx Studio application).  
4. Click Done to accept the new value and return to the System Connection page.  
5. Do not alter the Master Port Number value (this is the default value used by NetLinx).  
6. Enter a username and password (into their respective fields) if the target Master has been previously  
secured.  
7. Press the Back button to open the Protected Setup page.  
8. Press the on-screen Reboot button to both save any changes and restart the panel.  
45  
5" Modero Widescreen Touch Panel  
 
Configuring Communication  
Master Connection section - NetLinx Master Ethernet IP Address - Listen Mode  
In this mode, you must add the Modero panel IP Address into the URL List of the Master (using NetLinx  
Studio). This mode sets the Modero panel to "listen" for broadcasts from the Master (using the panel IP  
from its URL list).  
1. Obtain either a Static IP for the Modero panel (from your System Administrator) or a DHCP  
Address from the IP Settings of the System Connection page.  
The DHCP/Static field (in the IP Settings section of the System Connection page) must be set  
to DHCP to get Dynamic IP information for the panel.  
Press the on-screen Reboot (from the Protected Setup page) to both save any changes and  
restart the panel.  
After power-up, press the grey Front Setup Access button for 3 seconds to access the Setup  
page.  
Navigate to the Setup > Protected Setup > System Connection page and note the newly  
obtained Dynamic IP Address information from the IP Settings section. This information is  
then entered into the URL List for the connected NetLinx Master.  
2. Toggle the Type field until Ethernet is selected (from the Master Connection section of the System  
Connection page).  
3. Press the Mode field (to set the connection Mode) until the choice cycles to the word Listen. The  
System Number and Master IP/URL fields are then greyed-out.  
4. Enter a username and password (into their respective fields) if the target Master has been previously  
secured.  
5. Select the OnLine Tree tab from the Workspace window.  
6. Select Diagnostics > URL Listing from the Main menu (FIG. 42).  
System Address  
reflects the value  
set in the Device  
Addressing tab  
Used to obtain an  
existing URL  
List from Master  
Used to set the  
URL List  
on Master  
FIG. 42 URL List dialog  
7. Enter the System and Device number for the specific Master associated with your panel (as seen in  
the OnLine Tree tab).  
8. Click Add and enter the IP Address of the Modero touch panel into the Add URL dialog.  
9. Click OK to enter your IP Address and add it to the list.  
10. Click Done once you are finished adding your panel information to the list.  
11. Press the on-screen Reboot button to save any changes and restart the panel.  
46  
5" Modero Widescreen Touch Panel  
   
Configuring Communication  
Master Connection section - NetLinx Master Ethernet IP Address - Auto Mode  
In this mode, enter the System Number of the NetLinx Master. This mode instructs the Modero to search  
for a Master that uses the same System Number (assigned within the Master Connection section) and  
resides on the same Subnet as itself.  
1. Toggle the blue Type field until Ethernet is selected (from the Master Connection section of the  
System Connection page).  
2. Press the Mode field until the choice cycles to the word Auto.  
3. Press the System Number field to launch a Keypad and enter the value for the system number of the  
NetLinx Master. This value can be obtained from the NetLinx Studio program > OnLine Tree of the  
Workspace window.  
4. Do not alter the IP Settings section, of the System Connection page, as these fields are not  
applicable to this connection mode.  
5. Enter a username and password (into their respective fields) if the target Master has been previously  
secured.  
6. Press the on-screen Reboot button to both save any changes and restart the panel.  
7. Press the grey Front Setup Access button for 3 seconds to open the Setup page and confirm there is  
an active connection.  
The NetLinx Master and the Modero panel must both be on the same Subnet.  
Using G4 Web Control to Interact with a G4 Panel  
The G4 Web Control feature allows you to use a PC to interact with a G4 enabled panel via the web. This  
feature works in tandem with the new browser-capable NetLinx Security firmware update (build 300 or  
higher). G4 Web Control is only available with the latest Modero panel firmware.  
Refer to the G4 Web Control Page section on page 77 for more detailed field information.  
Verify your NetLinx Master (ME260/64 or NI-Series) has been installed with the latest  
firmware KIT file from www.amx.com. Refer to your NetLinx Master instruction  
manual for more detailed information on the use of the new web-based NetLinx  
Security.  
1. Press the grey Front Setup Access button for 3 seconds to open the Setup page.  
2. Press the Protected Setup button (located on the lower-left of the panel page) to open the Protected  
Setup page and display an on-screen keypad.  
3. Enter 1988 into the Keypad’s password field (1988 is the default password).  
Clearing Password #5, from the initial Password Setup page, removes the need for  
you to enter the default password before accessing the Protected Setup page.  
4. Press Done when finished.  
5. Press the G4 WebControl button to open the G4 Web Control page (FIG. 43).  
6. Press the Enable/Enabled button until it toggles to Enabled (light blue color).  
47  
5" Modero Widescreen Touch Panel  
     
Configuring Communication  
FIG. 43 G4 Web Control page  
7. The Network Interface Select field is read-only and displays the method of communication to the  
web. Verify you have selected the proper interface connection as this field does not auto-detect  
the connection type being used (see below).  
Wired is used when a direct Ethernet connection is being used for communication to the web.  
This is the default setting if either no wireless interface card is detected or if both an Ethernet  
and wireless card connection is detected by the panel.  
Wireless is used when a wireless card is detected within the internal card slot. The CV5 panel  
does not provide wireless communication and therefore this option is not available.  
8. Press the Web Control Name field to open the Web Name keyboard.  
9. From the Web Name keyboard, enter a unique alpha-numeric string to identify this panel. This  
information is used by the NetLinx Security Web Server to display on-screen links to the panel. The  
on-screen links use the IP Address of the panel and not the name for communication (FIG. 44).  
FIG. 44 Sample relationship between G4 Web Control and Mange WebControl Connections window  
10. Press Done after you are finished assigning the alpha-numeric string for the Web Control name.  
11. Press the Web Control Password field to open the Web Password keyboard.  
12. From the Web Password keyboard, enter a unique alpha-numeric string to be assigned as the G4  
Authentication session password associated with VNC web access of this panel.  
13. Press Done after you are finished assigning the alpha-numeric string for the Web Control password.  
14. Press the Web Control Port field to open the Web Port Number keypad.  
15. Within the keypad, enter a unique numeric value to be assigned to the port the VNC Web Server is  
running on. The default value is 5900.  
48  
5" Modero Widescreen Touch Panel  
   
Configuring Communication  
16. Press Done when you are finished entering the value. The remaining fields within the G4 Web  
Control Settings section of this page are read-only and cannot be altered.  
17. Press the Up/Down arrows on either sides of the G4 Web Control Timeout field to increase or  
decrease the amount of time the panel can remain idle (no cursor movements) before the session is  
closed and the user is disconnected.  
18. Press the Back button to open the Protected Setup page.  
19. Press the on-screen Reboot button to save any changes and restart the panel.  
Verify your NetLinx Master’s IP Address and System Number have been properly  
entered into the Master Connection section of the System Connection page.  
Using your NetLinx Master to control the G4 panel  
Refer to your particular NetLinx Master’s instruction manual for detailed information on how to  
download the latest firmware from www.amx.com. This firmware build enables SSL certificate  
identification and encryption, HTTPS communication, ICSP data encryption, and disables the ability to  
alter the Master security properties via a TELNET session.  
In order to fully utilize the SSL encryption, your web browser should incorporate the an encryption  
feature. This encryption level is displayed as a Cipher strength.  
Once the Master’s IP Address has been set through NetLinx Studio version 2.x or higher:  
1. Launch your web browser.  
2. Enter the IP Address of the target Master (ex: http://198.198.99.99) into the web browser’s Address  
field.  
3. Press the Enter key on your keyboard to begin the communication process between the target  
Master and your computer.  
Initially, the Master Security option is disabled (from within the System Security page) and  
no username and password is required for access or configuration.  
Both HTTP and HTTPS Ports are enabled by default (via the Manage System > Server  
page).  
If the Master has been previously configured for secured communication, click OK to accept  
the AMX SSL certificate (if SSL is enabled) and then enter a valid username and password  
into the fields within the Login dialog.  
4. Click OK to enter the information and proceed to the Master’s Manage WebControl Connections  
window.  
5. This Manage WebControl Connections page (FIG. 45) is accessed by clicking on the Manage  
connections link (within the Web Control section within the Navigation frame). Once activated, this  
page displays links to G4 panels running the latest G4 Web Control feature (previously setup and  
activated on the panel).  
49  
5" Modero Widescreen Touch Panel  
 
Configuring Communication  
Compatible  
devices field  
(showing G4  
WebControl links)  
G4 panels  
Compression  
Options  
FIG. 45 Manage WebControl Connections page (populated with compatible panels)  
6. Click on the G4 panel name link associated with the target panel. A secondary web browser window  
appears on the screen (FIG. 46).  
FIG. 46 Web Control VNC installation and Password entry screens  
7. Click Yes from the Security Alert popup window to agree to the installation of the G4 WebControl  
application on your computer. This application contains the necessary Active X and VNC client  
applications necessary to properly view and control the panel pages from your computer.  
The G4 Web Control application is sent by the panel to the computer that is used for  
communication. Once the application is installed, this popup will no longer appear.  
This popup will only appear if you are connecting to the target panel using a different  
computer.  
8. In some cases, you might get a Connection Details dialog (FIG. 47) requesting a VNC Server IP  
Address. This is the IP Address not the IP of the Master but of the target touch panel. Depending on  
which method of communication you are using, it can be found in either the:  
Wired Ethernet - System Connection > IP Settings section within the IP Address field.  
Wireless - Not available with the CV5 panel.  
If you do not get this field continue to step 9.  
50  
5" Modero Widescreen Touch Panel  
   
Configuring Communication  
IP Address of touch panel  
- obtained from IP Settings section of  
the System Connection page  
FIG. 47 Connection Details dialog  
9. If a WebControl password was setup on the G4 WebControl page, a G4 Authentication Session  
password dialog box appears on the screen within the secondary browser window.  
10. Enter the Web Control session password into the Session Password field (FIG. 46). This password  
was previously entered into the Web Control Password field within the G4 Web Control page on the  
panel.  
11. Click OK to send the password to the panel and begin the session. A confirmation message appears  
stating "Please wait, Initial screen loading..".  
The secondary window then becomes populated with the same G4 page being displayed on the target G4  
panel. A small circle appears within the on-screen G4 panel page and corresponds to the location of the  
mouse cursor. A left-mouse click on the computer-displayed panel page equates to an actual touch on the  
target G4 panel page.  
51  
5" Modero Widescreen Touch Panel  
 
Configuring Communication  
52  
5" Modero Widescreen Touch Panel  
Upgrading Modero Firmware  
Upgrading Modero Firmware  
Before beginning the Upgrade process:  
Setup and configure your NetLinx Master. Refer to the your particular NetLinx Master  
Instruction Manual for detailed setup procedures.  
Calibrate and prepare the communication pages on the Modero panel for use. Refer to the  
Refer to the NetLinx Studio version 2.x or higher Help file for more information on uploading  
files via Ethernet.  
Configure your panel for a direct connection. Refer to the Configuring  
Communication section on page 33 for more information.  
It is recommended that firmware Kit files only be transferred over a direct Ethernet  
connection and only when the panel is connected to a power supply.  
The process of updating firmware involves the use of a communicating NetLinx Master. The required  
steps for updating firmware to a Modero panel are virtually identical to those necessary for updating Kit  
files to a NetLinx Master (except the target device is a panel instead of a Master). Refer to either your  
Master’s literature or Studio 2.x Help file for those procedures.  
A touch panel which is not using a valid username and password will not be able to  
communicate with a secured Master. If you are updating the firmware on or through a  
panel which is not using a username or password field, you must first remove the  
Master Security feature to establish an unsecured connection.  
Upgrading the Modero Firmware via the USB port  
Before beginning with this section, verify your panel is both powered and the Type-A USB connector is  
securely inserted into the PC’s USB port. The panel must be powered-on before connecting the  
mini-USB connector to the panel.  
Establishing a USB connection between the PC and the panel, prior to installing the  
latest NetLinx Studio and TPDesign4 applications will cause a failure in the USB  
driver installation.  
This driver must first be saved to the PC as part of the new NetLinx Studio and  
TPDesign4 application installations.  
Step 1: Configure the panel for a USB Connection Type  
1. After the installation of the USB driver has been completed; confirm the proper installation of the  
large Type-A USB connector to the PC's USB port, and restart your machine.  
2. After the CV5 panel powers-up, press and hold the grey Front Setup Access button (for 3 seconds)  
to continue with the setup process and proceed to the Setup page.  
3. Select Protected Setup > System Settings (located on the lower-left) to open the System Settings  
page.  
4. Toggle the blue Type field (from the Master Connection section) until the choice cycles to USB.  
53  
5" Modero Widescreen Touch Panel  
     
Upgrading Modero Firmware  
ALL fields are then greyed-out and read-only, but still display any previous network  
information.  
5. Press the Back button on the touch panel to return to the Protected Setup page.  
6. Press the on-screen Reboot button to both save any changes and restart the panel. Remember that  
the panel’s connection type must be set to USB prior to rebooting the panel and prior to inserting  
the USB connector.  
7. ONLY AFTER the unit displays the first panel page, THEN insert the mini-USB connector into  
the Program Port on the panel. It may take a minute for the panel to detect the new connection and  
send a signal to the PC (indicated by a green System Connection icon).  
If a few minutes have gone by and the System Connection icon still does not turn green,  
complete the procedures in the following section to setup the Virtual Master and refresh the  
System from the Online Tree. This action sends out a request to the panel to respond and  
completes the communication (turning the System Connection icon green).  
8. Navigate back to the System Connection page.  
Step 2: Prepare NetLinx Studio for communication via the USB port  
1. Launch NetLinx Studio 2.x (default location is Start > Programs > AMX Control Disc > NetLinx  
Studio 2 > NetLinx Studio 2).  
2. Select Settings > Master Communication Settings, from the Main menu to open the Master  
Communication Settings dialog (FIG. 48).  
IP Address of computer  
(not needed as this is a direct  
USB connection)  
FIG. 48 Assigning Communication Settings for a Virtual Master  
3. Click the Communications Settings button to open the Communications Settings dialog.  
4. Click on the NetLinx Master radio button (from the Platform Selection section) to indicate that you  
are working as a NetLinx Master.  
5. Click on the Virtual Master radio box (from the Transport Connection Option section) to indicate  
you are wanting to configure the PC to communicate directly with a panel. Everything else such as  
the Authentication is greyed-out because you are not going through the Master’s UI.  
6. Click the Edit Settings button (on the Communications Settings dialog) to open the Virtual NetLinx  
Master Settings dialog (FIG. 48).  
54  
5" Modero Widescreen Touch Panel  
   
Upgrading Modero Firmware  
7. From within this dialog enter the System number (default is 1).  
8. Click OK three times to close the open dialogs, save your settings, and return to the main NetLinx  
Studio application.  
9. Click the OnLine Tree tab in the Workspace window to view the devices on the Virtual System. The  
default System value is one.  
10. Right-click on the Empty Device Tree/System entry and select Refresh System to re-populate the  
list.  
The panel will not appear as a device below the virtual system number (in the Online Tree tab)  
until both the system number used in step 7 for the Virtual NetLinx Master (VNM) is entered into  
the Master Connection section of the System Connection page and the panel is restarted.  
If the G4 panel does not appear, refer to the Troubleshooting section on page 143 for  
more information.  
Step 3: Confirm and Upgrade the firmware via the USB port  
Use the CC-USB Type-A to Mini-B 5-wire programming cable (FG10-5965) to provide communication  
between the mini-USB Program port on the touch panel and the PC. This method of communication is  
used to transfer firmware Kit files and TPD4 touch panel files.  
A mini-USB connection is only detected after it is installed onto an active panel.  
Connection to a previously powered panel which then reboots, allows the PC to  
detect the panel and assign an appropriate USB driver.  
1. Verify this direct USB connection (Type-A on the panel to mini-USB on the panel) is configured  
properly using the steps outlined in the previous two sections.  
2. With the panel already configured for USB communication and the Virtual Master setup within  
NetLinx Studio, its now time to verify the panel is ready to receive files.  
3. After the Communication Verification dialog window verifies active communication between the  
Virtual Master and the panel, click the OnLine Tree tab in the Workspace window (FIG. 49) to  
view the devices on the Virtual System. The default System value is one.  
4. Right-click on the System entry (FIG. 49) and select Refresh System to re-populate the list.  
Verify the panel appears in the OnLine Tree tab of the Workspace window.  
The default Modero panel value is 10001.  
Showing the Virtual Master  
firmware version and  
device number  
Shows NetLinx Studio  
version number  
Showing the current Modero  
panel firmware version and  
device number  
FIG. 49 NetLinx Workspace window (showing the panel connection via a Virtual NetLinx Master)  
55  
5" Modero Widescreen Touch Panel  
   
Upgrading Modero Firmware  
The panel firmware is shown on the right of the listed panel.  
Download the latest firmware file from www.amx.com and then save the Kit file to  
your computer.  
5. If the panel firmware being used is not current, download the latest Kit file by first logging in to  
www.amx.com and then navigate to Tech Center > Firmware Files and from within the Modero  
section of the web page locate your Modero panel.  
6. Click on the desired Kit file link and after you’ve accepted the Licensing Agreement, verify you  
have downloaded the Modero Kit file to a known location.  
7. From within Studio, select Tools > Firmware Transfers > Send to NetLinx Device from the Main  
menu to open the Send to NetLinx Device dialog (B in FIG. 50). Verify the panel’s System and  
Device number values match those values listed within the System folder in the OnLine Tree tab of  
the Workspace window (A in FIG. 50).  
B
A
FIG. 50 Using USB for a Virtual Master transfer  
8. Select the panel’s Kit file from the Files section.  
9. Enter the Device value associated with the panel and the System number associated with the Master  
(listed in the OnLine Tree tab of the Workspace window). The Port field is greyed-out.  
10. Click the Reboot Device checkbox. This causes the touch panel to reboot after the firmware update  
process is complete. The reboot of the panel can take up 30 seconds after the firmware process has  
finished.  
11. Click Send to begin the transfer. The file transfer progress is indicated on the bottom-right of the  
dialog (B in FIG. 50).  
12. As the panel is rebooting, temporarily unplug the USB connector on the panel until the panel has  
completely restarted.  
13. Once the first panel page has been displayed, reconnect the USB connector to the panel.  
14. Right-click the associated System number and select Refresh System. This causes a refresh of all  
project systems, establishes a new connection to the Master, and populates the System list with  
devices on your particular system.  
15. Confirm the panel has been properly updated to the correct firmware version.  
56  
5" Modero Widescreen Touch Panel  
 
Upgrading Modero Firmware  
Upgrading the Modero Firmware via Ethernet (IP Address)  
Before beginning with this section, verify that your panel is powered and connected to the NetLinx  
Master through an Ethernet connection.  
Step 1: Prepare the Master for communication via an IP  
1. Obtain the IP Address of the NetLinx Master from your System Administrator. If you do not have  
an IP Address for the Master, refer to your particular Master’s instruction manual for more  
information on obtaining this IP Address using NetLinx Studio 2.x or higher.  
From the Online Tree tab of the Workspace window, select the NetLinx Master.  
Follow steps outlined in either the Obtaining or Assigning the Master’s IP Address sections  
from your particular NetLinx Master instruction manual to use an address.  
Note the IP Address and Gateway information.  
2. Launch NetLinx Studio 2.x (default location is Start > Programs > AMX Control Disc > NetLinx  
Studio 2 > NetLinx Studio 2).  
3. Select Settings > Master Communication Settings from the Main menu to open the Master  
Communication Settings dialog (FIG. 51).  
FIG. 51 Assigning Master Communication Settings and TCP/IP Settings  
4. Click the Communications Settings button to open the Communications Settings dialog.  
5. Click on the NetLinx Master radio button (from the Platform Selection section) to indicate you are  
working with a NetLinx Master (such as the NXC-ME260/64 or NI-Series of Integrated  
Controllers).  
6. Click on the TCP/IP radio button (from the Transport Connection Option section) to indicate you  
are connecting to the Master through an IP Address.  
7. Click the Edit Settings button (on the Communications Settings dialog) to open the TCP/IP  
Settings dialog (FIG. 51). This dialog contains a series of previously entered IP Address/URLs and  
their associated names, all of which are stored within Studio and are user-editable.  
57  
5" Modero Widescreen Touch Panel  
     
Upgrading Modero Firmware  
8. Click the New button to open the New TCP/IP Settings dialog where you can enter both a  
previously obtained DHCP or Static IP Address and an associated description for the connection  
into their respective fields.  
9. Place a checkmark within the Automatically Ping the Master Controller to ensure availability radio  
box to make sure the Master is initially responding online before establishing full communication.  
10. Click OK to close the current New TCP/IP Settings dialog and return to the previous TCP/IP  
Settings dialog where you must locate your new entry within the List of Addresses section.  
11. Click the Select button to make that the currently used IP Address communication parameter.  
12. Click OK to return to the Communications Settings dialog and place a checkmark within the  
Authentication Required radio box if your Master has been previously secured with a username/  
password.  
13. Click on the Authentication Required radio box (if the Master is secured) and then press the User  
Name and Password button to open the Master Controller User Name and Password dialog.  
14. Within this dialog, you must enter a previously configured username and password (with sufficient  
rights) before being able to successfully connect to the Master.  
15. Click OK to save your newly entered information and return to the previous Communication  
Settings dialog where you must click OK again to begin the communication process to your Master.  
If you are currently connected to the assigned Master, a popup asks whether you  
would want to temporarily stop communication to the Master and apply the new  
settings.  
16. Click Yes to interrupt the current communication from the Master and apply the new settings.  
17. Click Reboot (from the Tools > Reboot the Master Controller dialog) and wait for the System  
Master to reboot. The STATUS and OUTPUT LEDs should begin to alternately blink during the  
incorporation. Wait until the STATUS LED is the only LED to blink.  
18. Press Done once until the Master Reboot Status field reads *Reboot of System Complete*.  
19. Click the OnLine Tree tab in the Workspace window to view the devices on the System. The default  
System value is one (1).  
20. Right-click the associated System number and select Refresh System. This establishes a new  
connection to the specified System and populates the list with devices on that system. The  
communication method is then highlighted in green on the bottom of the NetLinx Studio window.  
Step 2: Prepare the panel for communication via an IP  
1. Press the blue Type field (from the Master Connection section) until the choice cycles to the word  
Ethernet.  
2. Press the blue Mode field until the choice cycles to the word URL.  
By selecting URL, the System Number field becomes read-only (grey) because the panel pulls  
this value directly from the communicating target Master (virtual or not). A Virtual Master  
system value can be set within the active AMX software applications such as: NetLinx Studio,  
TPD4, or IREdit.  
3. Press the red Master IP/URL field to open a Keyboard and enter the NetLinx Master’s  
IP Address (obtained from the Diagnostics - Networking Address dialog of the NetLinx Studio  
application).  
4. Click Done to accept the new value and return to the System Configuration page.  
5. Do not alter the Master Port Number value (this is the default value used by NetLinx).  
58  
5" Modero Widescreen Touch Panel  
 
Upgrading Modero Firmware  
6. Press the Back button to return to the Protected Setup page and press the on-screen Reboot button  
to restart the panel and save any changes.  
Step 3: Verify and Upgrade the panel firmware via an IP  
1. Click the OnLine Tree tab in the Workspace window to view the devices on the System.  
The default System value is one.  
2. Right-click the associated System number (from the Workspace window) and select Refresh  
System to detect of all devices on the current system, establish a new connection to the Master, and  
refresh the System list with devices on that system.  
3. After the Communication Verification dialog window verifies active communication between the  
PC and the Master, verify the panel appears in the OnLine Tree tab of the Workspace window  
(FIG. 52). The default Modero panel value is 10001.  
Showing the NetLinx Master  
firmware version and  
device number  
Showing the current Modero  
panel firmware version and  
device number  
Shows NetLinx Studio  
version number  
FIG. 52 NetLinx Workspace window (showing connected Modero panel)  
The panel firmware is shown on the right of the listed panel.  
4. If the panel firmware being used is not current, download the latest Kit file by first logging in to  
www.amx.com and then navigate to Tech Center > Firmware Files and from within the Modero  
section of the web page locate your Modero panel.  
5. Click on the desired Kit file link and after you’ve accepted the Licensing Agreement, verify you  
have downloaded the Modero Kit file to a known location.  
6. From within Studio, select Tools > Firmware Transfers > Send to NetLinx Device from the Main  
menu to open the Send to NetLinx Device dialog (FIG. 53). Verify the panel’s System and Device  
number values match those values listed within the System folder in the OnLine Tree tab of the  
Workspace window.  
7. Select the panel’s Kit file from the Files section (FIG. 53).  
8. Enter the Device value associated with the panel and the System number associated with the Master  
(listed in the OnLine Tree tab of the Workspace window). The Port field is greyed-out.  
9. Click the Reboot Device checkbox. This causes the touch panel to reboot after the firmware update  
process is complete. The reboot of the panel can take up 30 seconds after the firmware process has  
finished.  
10. Click Send to begin the transfer. The file transfer progress is indicated on the bottom-right of the  
dialog (FIG. 53).  
59  
5" Modero Widescreen Touch Panel  
   
Upgrading Modero Firmware  
Selected Firmware file  
Description field for selected Kit file  
Firmware download  
status  
Device and System values  
listed in the Workspace window  
must match the System and Device values  
FIG. 53 Send to NetLinx Device dialog (showing Modero firmware update via IP)  
11. Click Close (after the panel reboots) to return to the main program.  
12. Right-click the associated System number and select Refresh System. This causes a refresh of all  
project systems, establishes a new connection to the Master, and populates the System list with  
devices on your particular system.  
13. Confirm the panel has been properly updated to the correct firmware version.  
60  
5" Modero Widescreen Touch Panel  
 
Firmware Pages and Descriptions  
Firmware Pages and Descriptions  
This section describes each firmware page and their specific functional elements.  
Setup Navigation Buttons  
These Setup Navigation Buttons (FIG. 54) appear on the left of the panel screen when the Setup page is  
currently active.  
Closes the Setup page  
Press to access the Protected Setup page for panel calibration and to access  
security release passwords and connection settings.  
Press to access the Information menu and select either Project Information or  
Panel Information.  
Press to access the Time Adjustment page where you can alter the time and  
date settings on the Master.  
Press the Audio Adjustments button to access the Audio Settings page where you can  
alter the audio parameters on the Modero panel.  
Press the Video Adjustment button to access the Video Adjustment page where  
you can set the video properties for incoming video.  
This button only appears on Color Video (CV) capable touch panels.  
FIG. 54 Setup Navigation Buttons  
Protected Setup  
This button opens the Protected Setup page which centers around the properties used by the panel to  
properly communicate with the NetLinx Master. Refer to both the Protected Setup Navigation  
61  
5" Modero Widescreen Touch Panel  
       
Firmware Pages and Descriptions  
Setup Page  
This page (FIG. 55) centers around basic Modero panel properties such as: Connection Status of the  
panel, Display Timeout, Inactivity Page Flip Time, Inactivity page file, and the Panel Brightness.  
Connection Status  
Red Connection Status icon -  
indicates no connection  
to a Master  
Green Connection Status icon -  
indicates communication  
to a Master  
FIG. 55 Setup page  
The elements of the Setup page are described in the table below:  
Setup Page Elements  
Exit:  
Returns you to the Main touch panel page. In this case, the previous page is the  
default Main page.  
Connection Status icon:  
This visual display of the connection status allows the user to have a current  
update of the panel’s connection status regardless of what page is  
currently active.  
• A Lock only appears on the icon if the panel has established a connection  
with a currently secured target Master (requiring a username and password).  
Connection Status:  
Displays whether the panel is communicating externally, the encryption status  
of the communicating Master, what connection type is being used (Ethernet or  
USB), and what System the panel is a part of.  
This visual display of the connection status is also reflected at the upper-right of  
each firmware page. This allows the user to have a current visual update of the  
panel’s connection status regardless of what page is currently active.  
• When a connection is established, the message displayed is either:  
"Connected via Ethernet " or "Connected via USB ".  
• If no connection can be established by the Modero panel, it will continue to try  
and establish a connection while displaying: "Attempting via ...".  
• The word "Encrypted" appears only when an encrypted connection is  
established with a target Master.  
• The panel must be rebooted before incorporating any panel communication  
changes and detecting any active Ethernet connections.  
The Ethernet connection is not detected until after a reboot.  
Display/Panel Timeout:  
Sets the length of time the panel can remain idle before activating the sleep  
mode. When the device goes into sleep mode, the LCD is powered-down.  
• Press the UP/DN buttons to increase/decrease the time until the panel  
times out. Range = 0 - 240 minutes.  
• Use this button to set the timeout value to zero and disable the sleep mode.  
• Note: Display timeout values affect battery performance. Small timeout values  
increase the life of the battery charge. Greater timeout values may require  
more frequent battery charging.  
62  
5" Modero Widescreen Touch Panel  
   
Firmware Pages and Descriptions  
Setup Page Elements (Cont.)  
Inactivity Page Flip  
Timeout:  
Sets the number of minutes of inactivity before the panel automatically flips to a  
pre-selected touch panel page. When the device goes into this inactivity mode,  
the LCD does not power-down.  
• Press the UP/DN buttons to increase/decrease the time the panel can remain  
inactive before it flips to the preset page. Range = 0 - 240 minutes.  
• Use this button to set the timeout value to zero and disable the inactivity page  
flip mode.  
• The touch panel page used for the Inactivity page flip is shown within a small  
Inactivity Page field.  
Panel Brightness:  
Sets the display brightness level of the panel.  
• Press the UP/DN buttons to adjust the brightness level. Range = 0 - 100.  
• The on-screen bargraph can be dragged to adjust the Brightness level which  
is then reflected as a corresponding numeric value within the Panel  
Brightness field.  
Information  
The Information button provides a menu to select either the Project Information Page section on  
page 64 or the Panel Information Page section on page 65. Select either option to access that page.  
FIG. 56 Information menu  
63  
5" Modero Widescreen Touch Panel  
 
Firmware Pages and Descriptions  
Project Information Page  
The Project Information page displays the TPDesign4 (TPD4) project file properties currently loaded on  
the selected Modero panel (FIG. 57). Refer to the TPDesign4 Touch Panel Program instruction manual  
for more specific information on uploading TPDesign4 files to a panel.  
FIG. 57 Project Information page (showing the TPD4 project properties tabs)  
The elements of the Project Information page are described in the table below:  
Project Information Page Elements  
Back:  
Returns you to the previously active touch panel page.  
Connection Status icon:  
This visual display of the connection status allows the user to have a current  
visual update of the panel’s connection status regardless of what page is  
currently active.  
• A Lock only appears on the icon if the panel has established a connection  
with a currently secured target Master (requiring a username and password).  
File Name:  
Displays the name of the TPDesign4 project file downloaded to the panel.  
Displays the designer information.  
Designer ID:  
File Revision:  
Dealer ID:  
Displays the revision number of the file.  
Displays the dealer ID number (unique to every dealer and entered in TPD4).  
Displays the job name.  
Job Name:  
Sales Order:  
Purchase Order:  
Displays the sales order information.  
Displays the purchase order information.  
AMX IR 38k Assigned Port: Displays the AMX 38 kHz IR channel port used by the IR receiver on the panel.  
• This information is pulled by the panel from AMX IR Receivers section of the  
TPD4 Project Properties > IR Emitters & Receivers tab.  
• For IR reception, this is the port that reports a push on for the corresponding  
IR code.  
• IR receivers and transmitters on G4 panels share the device address number  
of the panel.  
64  
5" Modero Widescreen Touch Panel  
   
Firmware Pages and Descriptions  
Project Information Page Elements (Cont.)  
AMX IR 455k  
Assigned Port:  
Displays the AMX 455 kHz IR channel port used by the IR receiver on the  
panel.  
This information is pulled by the panel from AMX IR Receivers section of the  
TPD4 Project Properties > IR Emitters & Receivers tab.  
• For IR reception, this is the port that reports a push on for the corresponding  
IR code.  
• IR receivers and transmitters on G4 panels share the device address number  
of the panel.  
Build Number:  
Displays the build number information of the TPD4 software used to create the  
project file.  
Creation Date:  
Revision Date:  
Last Save Date:  
Blink Rate:  
Displays the project creation date.  
Displays the last revision date for the project.  
Displays the last date the project was saved.  
Displays the feedback blink rate (10th of second).  
Job Comments:  
Displays any comments associated to the job. These comments are taken from  
the TPD4 project file.  
Panel Information Page  
The Panel Information page (FIG. 58) centers around Modero panel properties such as: resolution used,  
on-board memory, firmware, address/channel information, and string information.  
This information is retrieved  
from the Modero panel  
FIG. 58 Panel Information page (takes its’ information from the touch panel)  
The elements of the Panel Information page are described in the table below:  
Panel Information Page Elements  
Back:  
Returns you to the previously active touch panel page.  
Connection Status icon:  
This visual display of the connection status allows the user to have a current  
visual update of the panel’s connection status regardless of what page is  
currently active.  
• A Lock only appears on the icon if the panel has established a connection  
with a currently secured target Master (requiring a username and password).  
Panel Type:  
Displays the model of the Modero panel being used.  
Displays the G4 firmware version being used by the panel.  
• Verify you have the latest version from www.amx.com.  
Firmware Version:  
65  
5" Modero Widescreen Touch Panel  
   
Firmware Pages and Descriptions  
Panel Information Page Elements (Cont.)  
Setup Port:  
Displays the setup port information/value being used by the panel.  
Displays the high port (port count) value for the panel.  
High Port:  
High Address:  
High Channel:  
High Level:  
Displays the high address (address count) value for the panel.  
Displays the high channel (channel count) value for the panel.  
Displays the high level (level count) value being used by the panel.  
Displays the specific serial number value assigned to the panel.  
Displays the type and version of the Setup pages being used by the panel.  
Serial Number:  
Setup Pages Version:  
Screen Width:  
Displays the pixel width being used to display the incoming video signal on the  
Modero panel.  
• Maximum available screen width on a CV5 Modero panel is 800 pixels.  
Screen Height:  
Displays the pixel height being used to display the incoming video signal on the  
Modero panel.  
• Maximum available screen height on a CV5 Modero panel is 480 pixels.  
Screen Refresh Rate:  
Displays the video refresh rate applied to the incoming video signal from the  
panel. Default rate is 60.  
Screen Rotation:  
Power Up Pages:  
Displays the degree of rotation applied to the on-screen image.  
Displays the first touch panel page assigned for display after the device is  
powered-up.  
• This information is taken from the TPD4 project file.  
• Most projects begin with a Main page.  
Start Up String:  
Wake Up String:  
Sleep String:  
File System:  
RAM:  
Displays the start-up string.  
Displays the wake up string used after an activation from a timeout.  
Displays the sleep string used during a panel’s sleep mode.  
Displays the amount of Flash memory available on the Modero panel.  
Displays the available RAM (or Extended Memory module) on the Modero  
panel.  
Panel Start Time:  
Displays the last time the panel booted.  
Time & Date Setup Page  
The Time & Date Setup page (FIG. 59) allows you to alter/set the time and date information on  
the NetLinx Master. If either the Time/Date is modified on this page (then updated to the Master by  
pressing the Set Time button), all devices communicating to that target Master will then be updated to  
reflect the new information.  
Date Display  
fields  
Time Display  
fields  
Currently  
selected  
FIG. 59 Time and Date Setup page  
66  
5" Modero Widescreen Touch Panel  
   
Firmware Pages and Descriptions  
The only way to modify a panel’s time, without altering the Master, is to use NetLinx  
Code.  
The elements of the Time & Date Setup page are described in the table below:  
Time & Date Setup Page Elements  
Back:  
Returns you to the previously active touch panel page without saving changes  
(to save changes, use the Set Time button).  
Connection Status icon:  
This visual display of the connection status allows the user to have a current  
visual update of the panel’s connection status regardless of what page is  
currently active.  
• A Lock only appears on the icon if the panel has established a connection  
with a currently secured target Master (requiring a username and password).  
Time Date Refresh/Set:  
This section provides you with two options:  
• The Get Time/Date button retrieves the Time and Date information from the  
Master.  
• The Set Time/Date button sets the Master to retain and save any  
time/date modifications made on the Time and Date Setup page.  
Time Display fields:  
• These fields display the time in three formats: STANDARD, STANDARD  
AM/PM, and 24 HOUR.  
Date Display fields:  
Set Date/Time:  
• These fields display the calendar date information in several different formats.  
This section provides a user with both UP/DN arrow buttons to alter the  
Master’s calendar date and time. The blue circle indicates which field is cur-  
rently selected.  
• Select the Year field and use the UP/DN buttons to alter the year value  
(range = 2000 - 2037).  
• Select the Month field and use the UP/DN buttons to alter the month value  
(range = 1 - 12).  
• Select the Day field and use the UP/DN buttons to alter the day value  
(range = 1 - 31).  
• Select the Hour field and use the UP/DN buttons to alter the hour value  
(24-hour military).  
• Select the Minute field and use the UP/DN buttons to alter the minute value  
(range = 0 - 59).  
• Select the Second field and use the UP/DN buttons to alter the second value  
(range = 0 - 59).  
CV5 touch panels do not have an on-board clock. This page both receives and sets  
the time/date of the NetLinx Master.  
67  
5" Modero Widescreen Touch Panel  
Firmware Pages and Descriptions  
Audio Settings Page  
The Audio Settings page (FIG. 60) (accessed by pressing the Audio button on the Setup page) allows you  
to adjust the master volume parameters and default panel sounds on the panel.  
FIG. 60 Audio Settings page  
The elements of the Audio Settings page are described in the table below:  
Audio Settings Page Elements  
Back:  
Saves the changes and returns you to the previously active touch panel page.  
Connection Status icon:  
This visual display of the connection status allows the user to have a current  
visual update of the panel’s connection status regardless of what page is  
currently active.  
• A Lock only appears on the icon if the panel has established a connection  
with a currently secured target Master (requiring a username and password).  
Master Volume:  
This section allows you to alter the current master volume level:  
• Use the UP/DN buttons to adjust the volume level (range = 0 - 100).  
• The Master Volume bargraph indicates the current volume level.  
• The Mute button toggles the Mute feature.  
Internal Sound Level:  
This section allows you to adjust the current sound level on the internal panel  
speaker:  
• Use the UP/DN buttons to adjust the volume output on the internal speakers  
(range = 0 - 100).  
• The Internal Sound Level bargraph indicates the current sound level.  
• The Mute button mutes the volume.  
Default Panel Sounds:  
Sets the Modero panel to play various sounds.  
• Activating the Button Hit button plays a default sound when you touch an  
active button.  
• Activating the Button Miss button plays a default sound when you touch a  
non-active button or any area outside of the active button  
• The Play Test Sound button plays a test WAV/MP3 file over the panel’s  
internal speakers.  
68  
5" Modero Widescreen Touch Panel  
   
Firmware Pages and Descriptions  
Volume Page Elements (Cont.)  
Line In Level:  
Allows you to adjust the current Line-In volume level (being received from the  
communicating breakout box).  
• Use the UP/DN buttons to adjust the Line-In volume level (range = 0 - 100).  
• The Line-In Level bargraph indicates the current Line-In level.  
• The Mute button mutes the Line-In volume.  
Mic Out Level:  
Allows you to adjust the current Microphone volume level (being received from  
the communicating breakout box).  
• Use the UP/DN buttons to adjust the Microphone volume level  
(range = 0 - 100).  
• The Mic Out Level bargraph indicates the current Mic Out level.  
Supported sampling rates for WAV  
The following is a listing of supported sampling rates associated for WAV files played on a CV5 panel.  
Some WAV files currently played on Modero's may not work on these panels. The supported sampling  
rates for WAV files are:  
Supported WAV Sampling Rates  
• 48000 Hz  
• 44100 Hz  
• 32000 Hz  
• 24000 Hz  
• 22050 Hz  
• 16000 Hz  
• 12000 Hz  
• 11025 Hz  
• 8000 Hz  
Video Adjustment Page  
The Video Setup page (FIG. 61) (accessed by pressing the Video Adjustment button on the Setup page)  
sets the Video properties of the incoming video signal from an NXA-AVB/ETHERNET Breakout Box.  
Incoming Video signal  
Once done making your screen  
adjustments, SAVE SETTINGS.  
FIG. 61 Video Setup page (showing default values)  
69  
5" Modero Widescreen Touch Panel  
     
Firmware Pages and Descriptions  
The elements of the Video Setup page are described in the table below:  
Video Setup Page Elements  
Back:  
Saves the changes and returns you to the previously active touch panel page.  
Connection Status icon:  
This visual display of the connection status allows the user to have a current  
visual update of the panel’s connection status regardless of what page is  
currently active.  
• A Lock only appears on the icon if the panel has established a connection  
with a currently secured target Master (requiring a username and password).  
Settings:  
• The Default Settings button sets the video settings to their default values  
(indicated in this table).  
• The Undo Changes button disregards any changes made on the page since  
the last settings were saved.  
• The Save Settings button saves any changes made to this page.  
Video Settings:  
• The Black & White button toggles the Black & White display mode.  
Default = Off.  
• The Sharpness button toggles the Interpolate (Sharpness) feature.  
Default = Off.  
• The Interlace button toggles the Interlacing feature.  
Default = On.  
Status:  
Displays whether or not a video-sync signal is detected.  
Format:  
Allows you to press this blue field and cycle through a choice of available video  
formats (NTSC, MPAL, PAL, SECAM, or Auto detect).  
• Default = Auto.  
Brightness:  
Contrast:  
Saturation:  
Hue:  
Use the UP/DN buttons to alter the brightness level of the incoming signal.  
• Range = 0 - 255, default = 128.  
Use the UP/DN buttons to alter the contrast level of the incoming signal.  
• Range = 0 - 255, default = 128.  
Use the UP/DN buttons to alter the color saturation level of the incoming signal.  
• Range = 0 - 255, default = 128.  
Use the UP/DN buttons to alter the hue level of the incoming signal.  
• Range = 0 - 255, default = 128.  
70  
5" Modero Widescreen Touch Panel  
Firmware Pages and Descriptions  
Protected Setup Navigation Buttons  
The Protected Setup Navigation Buttons (FIG. 62) appear on the left of the panel screen when the  
Protected Setup page is currently active.  
Press to access the System Settings page where you can configure  
communication settings for the NetLinx Master and the panel.  
Press to access the Calibration page where you can calibrate the panel.  
Press to access the G4 Web Control page where you can enable or disable remot  
display and control of the panel via a web-enabled PC running a VNC client.  
Press the Sensors button to access the Sensors Setup page where you can  
modify/monitor both the light and motion sensor settings.  
Press to access the Other Settings menu and select either Cache or  
Passwords.  
Press to access the Tools menu and select either, Panel Logs, Panel Statistics, o  
Connection Utility.  
FIG. 62 Protected Setup Navigation Buttons  
71  
5" Modero Widescreen Touch Panel  
   
Firmware Pages and Descriptions  
Protected Setup Page  
The Protected Setup page (FIG. 63) centers around the properties used by the panel to properly  
communicate with the NetLinx Master. Enter the factory default password (1988) into the password  
keypad to access this page.  
Provides access to the panel  
firmware pages by enabling the  
grey front setup access button:  
- Setup page (after a 3 second  
press/hold)  
- Calibration page (after a 6 second  
press/hold)  
FIG. 63 Protected Setup page-showing default values  
The elements of the Protected Setup page are described in the table below:  
Protected Setup Page Elements  
Back:  
Saves the changes and returns you to the previously active touch panel page.  
Connection Status icon:  
This visual display of the connection status allows the user to have a current  
visual update of the panel’s connection status regardless of what page is  
currently active.  
• A Lock only appears on the icon if the panel has established a connection  
with a currently secured target Master (requiring a username and password).  
Device Number:  
Options:  
Opens a keypad that is used to set and display the current device number.  
Allows you to select various touch panel features:  
• The Function Show button enables the display of the channel port and  
channel code in the top left corner of the button, the level port and level code  
in the bottom left corner, and the address port and address code in the  
bottom right corner (see FIG. 65 for an example of the function locations).  
• Use the Page Tracking button to toggle page tracking. When enabled, the  
touch panel sends page data back to the NetLinx Master, or vice versa  
depending on the touch panel settings.  
• Use the Telnet button to enable or disable the telnet server on the panel. This  
feature focuses on direct telnet communication to the panel.  
• Use the Front Button Setup Access button to activate the grey Front Setup  
Access button (located below the LCD) to access the firmware pages.  
- Default condition is On.  
- Press and hold this grey button for 3 seconds to access the Setup page.  
- Press and hold this grey button for 6 seconds to access the Calibration  
page.  
Reboot Panel:  
Pressing this button causes the panel to restart after saving any changes.  
72  
5" Modero Widescreen Touch Panel  
   
Firmware Pages and Descriptions  
Protected Setup Page Elements (Cont.)  
System Recovery:  
Allows you to either reset the touch panel to factory default settings and/or wipe  
out all existing touch panel pages:  
• The Reset System Settings button allows a user to wipe out all current  
configuration parameters on the touch panel (such as IP Addresses, Device  
Number assignments, Passwords, and other presets).  
- Pressing this button launches a Confirmation dialog (FIG. 64) which asks  
you to confirm your selection.  
- This dialog is configured with a delay timer that does not enable the YES  
button for 5 seconds. This delay provides an additional amount of time for  
the user to confirm their decision.  
• The Remove User Pages button allows you remove all current TPD4 touch  
panel pages currently on the panel (including the pre-installed AMX Demo  
pages).  
- Pressing this button launches a Confirmation dialog (FIG. 64) which asks  
you to confirm your selection.  
- This dialog is configured with a delay timer that does not enable the YES  
button for 5 seconds. This delay provides an additional amount of time for  
the user to confirm their decision.  
You have a wait time of 5 seconds  
before the YES option is enabled.  
FIG. 64 Protected Setup page-System Recovery confirmation dialog  
Channel Code  
Number  
Channel Port  
Channel Code  
Number  
Channel Port  
Level Port  
7,10  
Slider  
Address  
Port  
3,132  
2,8  
Address  
Port  
Button  
Level Port  
4,9  
1,8  
3,50  
Channel Code  
Number  
Channel Code  
Number  
Address Code  
Number  
Address Code  
Number  
FIG. 65 Button/slider Function Show example  
73  
5" Modero Widescreen Touch Panel  
   
Firmware Pages and Descriptions  
System Settings Page  
The System Settings page (FIG. 66) sets the Secondary DNS Address information with its corresponding  
IP communication parameters, NetLinx Master communication settings, and reads the device number  
assigned to the Modero panel.  
IP Settings section  
Master Connection section  
(NetLinx Master properties)  
Master Connection features are not  
saved until the panel is rebooted  
Red fields are user-editable  
Blue fields cycle through choices  
Grey fields are read-only  
FIG. 66 System Settings page showing default values (reads and assigns values to the panel and Master)  
The elements of the System Settings page are described in the table below:  
System Settings Page Elements  
Back:  
Saves the changes and returns you to the previously active touch panel page.  
Connection Status icon:  
This visual display of the connection status allows the user to have a current  
visual update of the panel’s connection status regardless of what page is  
currently active.  
• A Lock only appears on the icon if the panel has established a connection  
with a currently secured target Master (requiring a username and password).  
IP Settings:  
Sets the IP communication values for the panel and contains:  
Sets the panel to either DHCP or Static communication modes.  
DHCP/Static  
DHCP (Dynamic Host Configuration Protocol) assigns IP Addresses from  
client stations logging onto a TCP/IP network via a DHCP server.  
Static IP is a permanent IP Address that is assigned to a node in a TCP/IP  
network.  
IP Address  
Sets the secondary IP Address assigned to the panel.  
Sets a subnetwork address to the panel.  
Subnet Mask  
Subnetwork mask is the technique used by the IP protocol to filter messages  
into a particular network segment (Subnet).  
Gateway  
Sets a gateway value to the panel.  
Gateway is a computer that either performs protocol conversion between  
different types of networks/applications or acts as a go-between two or more  
networks that use the same protocols.  
Host Name  
Sets the host name of the panel.  
Primary DNS  
Sets the address of the primary DNS server used for host name lookups.  
DNS (Domain Name System) is software that lets users locate computers on  
a local network or the Internet (TCP/IP network) by host and domain. The  
DNS server maintains a database of host names for its’ domain and their  
corresponding IP Addresses.  
Secondary DNS  
Domain  
Sets a secondary DNS value to the panel.  
Sets the unique name on the Internet to the panel for DNS look-up.  
• The panel belongs to the DNS domain.  
Ethernet Mode  
Sets the speed of the Ethernet connection to the panel.  
• Choices are: Auto, 10 Half Duplex, 10 Full Duplex, 100 Half Duplex, or  
100 Full Duplex.  
74  
5" Modero Widescreen Touch Panel  
     
Firmware Pages and Descriptions  
System Connection Page Elements (Cont.)  
IP Settings: (Cont.)  
MAC Address  
Displays a read-only field that is factory set by AMX for the built-in Ethernet  
interface.  
Master Connection:  
Sets the NetLinx Master communication values:  
Type  
Sets the NetLinx Master to communicate with the panel via either USB or  
Ethernet. This is based on the cable connection from the rear.  
ICSNet is not a supported option on this panel.  
Ethernet is a CAT-5 cable (10/100Base T terminated in an RJ-45 connector)  
used to network computers together and is used in most LAN (local area  
networks). This description is also used to refer to both wired and wireless  
communication.  
USB option cannot be used on Modero panels which are not equipped with a  
USB port.  
Mode  
Cycles between the different connection modes (URL, Listen, and Auto)  
(ETHERNET Only - disabled when USB is selected)  
URL - In this mode, enter the IP/URL, Master Port Number, and  
username/password (if used) on the Master.  
- The System Number field is read-only because the panel obtains this  
information from the communicating Master.  
Listen - In this mode, add the Modero panel address into the URL List in  
NetLinx Studio and set the connection mode to Listen. This mode allows the  
Modero touch panel to "listen" for the Master’s communication signals.  
- The System Number and Master IP/URL fields are red-only.  
Auto - In this mode, enter the System Number and a username/password  
(if applicable). This mode is used when both the panel and the NetLinx  
Master are on the same Subnet and the Master has its UDP feature enabled.  
- Master IP/URL field is read-only.  
System Number  
Master IP/URL  
Allows you to enter a system number. Default value is 0 (zero).  
(ETHERNET Only - disabled when USB is selected)  
Sets the Master IP or URL of the NetLinx Master.  
(ETHERNET Only - disabled when USB is selected)  
Master Port Number  
Allows you to enter the port number used with the NetLinx Master.  
• Default value is 1319. (ETHERNET Only - disabled when USB is selected)  
Username/Password  
If the target Master has been previously secured, enter the alpha-numeric string  
(into each field) assigned to a pre-configured user profile on the Master.  
This profile should have the pre-defined level of access/configuration rights.  
75  
5" Modero Widescreen Touch Panel  
Firmware Pages and Descriptions  
Calibration Page  
This page (FIG. 67) allows you to calibrate the touch panel using the pre-selected touch driver.  
Press and hold the grey Front Setup Access button (below the Modero LCD) for 6 seconds to  
access the Calibration page.  
Press the crosshairs to calibrate the panel and return to the last active firmware page.  
The request to touch the crosshairs  
is the first on-screen message  
Calibration successful is the second  
on-screen message that appears  
after the calibration process is  
completed  
On-screen crosshairs used for  
calibration of the touch device  
FIG. 67 Calibration page (actually 3 separate screens)  
If the calibration was improperly set and you cannot return to the Calibration  
page (through the panel’s firmware); you can access this firmware page via  
G4 WebControl where you can navigate to the Protected Setup page and press the  
Calibrate button through your VNC window.  
This action causes the panel to go to the Calibration page seen above, where you  
can physically recalibrate the actual touch panel again using the above procedures.  
76  
5" Modero Widescreen Touch Panel  
   
Firmware Pages and Descriptions  
G4 Web Control Page  
The G4 Web Control page (FIG. 68) centers around enabling and disabling both the display and control  
of your panel (via the web). An external PC running a VNC client (installed during the initial  
communication to the G4 panel) makes this possible.  
FIG. 68 G4 Web Control page  
Each panel supports the open standard Virtual Network Computing (VNC) interface. These panels  
contain a VNC server that allows them to accept a connection from any other device running a VNC  
client. Once a connection is established to that target device, the client can control the touch panel  
remotely. The elements of the G4 Web Control page are described in the table below:  
G4 Web Control Page Elements  
Back:  
Saves the changes and returns you to the previously active touch panel page.  
Connection Status icon:  
This visual display of the connection status allows the user to have a current  
visual update of the panel’s connection status regardless of what page is  
currently active.  
• A Lock only appears on the icon if the panel has established a connection  
with a currently secured target Master (requiring a username and password).  
G4 Web Control Settings: Sets the IP communication values for the touch panel and contains:  
Enable/Enabled  
• The Enable/Enabled button allows you to toggle between the two G4  
activation settings:  
- Enable - deactivates the G4 Web Control feature on the panel.  
- Enabled - activates the G4 Web Control feature on the panel and allows  
an external PC running a VNC client to access the panel (after the  
remaining fields are configured).  
Network Interface Select  
Displays the detected method of communication to the web:  
Wired is used when a direct Ethernet connection is being used for  
communication to the web. This is a default setting if no wireless interface  
card is detected by the panel.  
Wireless is used when a wireless card is detected within the internal card  
slot. This method is disable for the CV5 which does not provide wireless  
communcation.  
Web Control Name  
Allows you to enter a unique alpha-numeric string that is used as the display  
name of the panel within the Manage WebControl Connections window of the  
new NetLinx Security browser window.  
• This Web Control tab displays a G4 icon alongside the link to the Web Control  
Name given to this panel (FIG. 69).  
Web Control Password  
Allows you to enter the G4 Authentication session password associated for  
VNC web access of this panel.  
77  
5" Modero Widescreen Touch Panel  
     
Firmware Pages and Descriptions  
G4 Web Control Page Elements (Cont.)  
G4 Web Control Settings  
(Cont.):  
Web Control Port  
Allows you to enter the port value that the VNC Web Server runs on.  
• Default value is 5900.  
Maximum Number of  
Connections  
This read-only field displays the maximum number of users that can be  
simultaneously connected to the target panel via the web.  
• Default value is 1.  
Current Connection Count This read-only field displays the current number of users connected to the  
target panel via the web. This value cannot exceed the Maximum number field.  
G4 Web Control Timeout:  
Sets the length of time (in minutes) the panel can remain idle (no cursor  
movements) before the session is closed and the user is disconnected.  
• Minimum value = 0 minutes (panel never times-out)  
• Maximum value = 240 minutes (panel times-out after 240 minutes/4hours)  
FIG. 69 Sample relationship between G4 Web Control and Mange WebControl Connections window  
instructions on how to use the G4 Web Control page with the new web-based NetLinx Security  
application.  
Sensor Setup  
The Sensor Setup page (FIG. 70) allows you to adjust the Light and Motion Sensor parameters on a  
Modero touch panel.  
FIG. 70 Sensor Setup page  
78  
5" Modero Widescreen Touch Panel  
       
Firmware Pages and Descriptions  
A light level value between the Minimum and Maximum DIM Mode values delivers an  
average light level. The DIM mode Min Level can never exceed the DIM Mode Max  
Level.  
The elements of the Sensor Setup page are described in the table below:  
Sensor Setup Page Elements  
Back:  
Saves the changes and returns you to the previously active touch panel page.  
Connection Status icon:  
This visual display of the connection status allows the user to have a current  
visual update of the panel’s connection status regardless of what page is  
currently active.  
• A Lock only appears on the icon if the panel has established a connection  
with a currently secured target Master (requiring a username and password).  
Light Sensor:  
Allows you to monitor and alter the sensitivity of the Modero panel light sensor:  
• The Light Sensor Level field indicates the level used to report the light  
sensor level back to the NetLinx Master (set in TPD4) (read-only).  
• The Light Sensor Level Port field indicates the port used to report the light  
sensor level back to the NetLinx Master (set in TPD4) (read-only).  
• The Light Sensor Channel field indicates the level used to report the sensor  
channel back to the NetLinx Master (set in TPD4). It is On when you are  
below the Maximum dim mode level (read-only).  
• The Light Sensor Channel Port field indicates the port used to report the  
sensor channel back to the NetLinx Master (set in TPD4) (read-only).  
• The Light Level field provides a numeric value representing the current value  
of the light level detected by the on-board photo-sensor.  
• The Light Level bargraph displays a horizontal bargraph indicating the current  
value of the light level detected by the on-board photo-sensor. This bargraph  
provides a visual representation of the numeric value displayed within the  
Light Level field.  
• Use the Dim Mode Max Level bargraph to alter the Maximum DIM level  
value used to activate the DIM Mode Brightness Level (range = 0 - 100).  
• Use the Dim Mode Min Level bargraph to alter the Minimum DIM level value  
used to activate the DIM Mode Brightness Level (range = 0 - 100).  
- The position of this bargraph can never exceed that of the Dim Mode  
Max Level.  
Dim Mode Minimum  
Brightness:  
Allows you to alter the sensitivity of the Modero panel light sensor:  
Toggle the Enable/Enabled button to either active/inactive the DIM Mode  
feature:  
- Enable - activates this feature. Once active (by receiving a value below the  
Dim Mode Min Level value), the current light level ramps to the DIM Mode  
value within a few seconds.  
- Enabled - (illuminated when selected) deactivates this feature.  
• Use the DIM Mode Brightness UP/DN buttons to alter the DIM level.  
- Range = 0 - 100.  
- The lower the value, the darker a room must be before the LCD Brightness  
value changes to conform to a DIM room (and vice versa with a  
higher value).  
• The DIM Mode Minimum Brightness bargraph indicates the current DIM  
Mode Brightness level.  
- This level corresponds to the brightness level of the LCD used when  
the DIM Mode is active.  
- The Brightness value of the panel in a DIM room (low-light) is much  
less than that of a Non-DIM (well to brightly-lit) where the LCD Brightness  
must be higher to display the screen content clearly.  
79  
5" Modero Widescreen Touch Panel  
Firmware Pages and Descriptions  
Sensor Setup Page Elements (Cont.)  
Motion Sensor:  
Provides the following fields:  
• The Motion Detection field displays a reactive button that changes color  
(illuminates) and displays the words "Motion Detected" when motion is  
detected by the Modero panel’s front motion sensor.  
• The Motion Sensor Port field indicates the port used to report the motion  
sensor channel back to the NetLinx Master (set in TPD4) (read-only).  
• The Motion Sensor Channel field indicates the channel used to report the  
motion sensor channel back to the NetLinx Master (set in TPD4) (read-only).  
Wake Panel On Motion  
Sense:  
The Wake Panel Sensitivity relates to the sensitivity of the motion sensor to  
detect motion and wake the panel accordingly.  
Toggle the Enable/Enabled button to either active/inactive this feature:  
- Enable - activates this feature. Activating this feature reactivates the  
panel from a panel timeout (sleep) mode.  
- Enabled - (illuminated when selected) deactivates this feature and  
makes the panel use the specified Display Timeout value set on the  
Setup Page.  
• Use the Wake Panel UP/DN buttons to alter the sensitivity value.  
- Range = 0 - 100.  
• The horizontal WAKE PANEL SENSITIVITY bargraph indicates the current  
motion sensitivity value associated with waking the panel from a timeout.  
There is a relationship between the motion sensor and the panel sleep feature. If a  
panel is set to Sleep Mode, there is a time delay before the motion sensor is activated  
to detect motion. By creating a time delay to the detection, this allows a user to set  
the sleep mode and leave the panels’ detection range. In this way, the panel doesn’t  
awake immediately after the sleep is active and you move away.  
Making the most of the Automated Brightness Control feature (DIM Mode)  
Please follow the steps below to set up Automated Brightness Control:  
1. Set the lighting conditions in the room to maximum (turn On all the lights).  
2. Set the Maximum Panel Brightness, from the Setup page, to a comfortable level.  
Sitting in front of the panel, you should be able to comfortably see someone sitting  
behind the panel without being “blinded” by the panel.  
3. Open the Sensors Setup page (FIG. 70) from the Protected Setup menu section.  
4. Move around the panel and block the direct or indirect light from the room fixtures with your body.  
Take note of the drop in the lighting level being detected by the panel in response to your  
movements.  
5. Set the Maximum brightness of the Dimmer (Dim Mode Max Level) below the detected drop. This  
will make sure that the panel does not react to variations in the lighting conditions of a normal  
working environment.  
The maximum (upper level) of the dimmer should be at least 15% lower than the  
maximum detected level.  
6. Set the minimum lighting conditions in the room (not complete darkness but the minimal lighting  
setup, unless complete darkness is an “operational option” for the room).  
80  
5" Modero Widescreen Touch Panel  
 
Firmware Pages and Descriptions  
7. Set the Minimum Dimmer Brightness (Dim Mode Min Level) to a comfortable level by sitting in  
front of the panel. You should be able to comfortably see someone sitting behind the panel without  
being “blinded” by the panel.  
8. Move around the panel and block the direct or indirect light from the room fixtures with your body.  
Take note of the drop in the lighting level being detected by the panel in response to your  
movements.  
9. Set the Minimum brightness of the Dimmer (Dim Mode Max Level) below the detected drop. This  
will make sure that the panel does not react to variations in the lighting conditions of a normal  
working environment.  
The minimum (lower level) of the dimmer should be at least 10% lower than the  
minimum detected level (ex: lower dimmer level at 30% if the detected lighting of the  
room is at 40%).  
Other Settings  
The Other Settings button provides a menu to select either the Image Caching Page section on page 82 or  
the Password Settings Page section on page 84. Select either option to access that page.  
FIG. 71 Other Settings menu  
81  
5" Modero Widescreen Touch Panel  
 
Firmware Pages and Descriptions  
Image Caching Page  
The Image Caching page (FIG. 72) configures the allocation of memory for image caching. The G4  
graphics engine caches images to decrease load time of previously viewed images. RAM caching is  
always enabled, and images (both static and dynamic) are stored in the RAM cache as they are viewed.  
The size of RAM cache is automatically configured to take into account available memory versus  
memory that may be needed by the panel later. As the RAM cache approaches its maximum size, the  
oldest items in the cache may be discarded to make room for newer items. If Flash caching is enabled,  
dynamic images that would have been discarded will actually be moved to Flash, since it is typically  
faster to retrieve images on Flash than across a network (although it is slower than RAM cache). Note  
that since static images are already stored on Flash, they are never moved to the Flash cache, so Flash  
caching applies only to dynamic images. Images in Flash cache are moved back to RAM cache the next  
time they are viewed. As the Flash cache approaches its maximum size, the least recently used items may  
be discarded to make room for new items.  
FIG. 72 Image Caching Page  
The elements of this page include:  
Image Caching Page Elements  
Back:  
Saves all changes and returns to the previous page.  
Connection Status icon:  
The icon in the upper-right corner of each Setup page shows online/offline state  
of the panel to the master.  
• Bright red - disconnected  
• Bright green - connected. Blinks when a blink message is received to dark  
green every 5 seconds for half a second then go back to bright green.  
• Bright yellow - panel missed a blink message from the master. It will remain  
yellow for 3 missed blink messages and then turn red. It will return to green  
when a blink message is received.  
Note: a Lock appears on the icon if the panel is connected to a secured NetLinx  
Master.  
Image Cache Settings:  
Allocates Flash memory for image caching.  
Flash Cache Size  
Press the Up and Down arrows to add and remove memory. Flash memory  
allocation cannot exceed the amount of Flash memory on the panel.  
82  
5" Modero Widescreen Touch Panel  
   
Firmware Pages and Descriptions  
Image Caching Page Elements (Cont.)  
Flash/RAM Cache Expires Press the Up and Down arrows to change the amount of time the images stay  
in cache memory. The options are:  
• Never  
• 2 Hours  
• 8 Hours  
• 1 Day  
• 2 Days  
• 5 Days  
Enable:  
Press this button to toggle the image Flash cache option On and Off.  
Press this button to clear both the Flash and RAM cache of all stored images.  
The status of the memory available versus in use.  
Clear Cache:  
Image Cache Status:  
RAM Max Size  
RAM Current Size  
RAM Hit Rate  
The maximum amount of memory available for all image caching.  
The memory that is currently in use for caching static and dynamic images.  
The percentage of image requests (static and dynamic) satisfied by accessing  
the cache.  
100 * (# of cache hits) / (# of cache hits + # of cache misses)  
# of cache hits - the number of times an image was requested that the image  
was found in the cache  
# of cache misses - the number of times an image was requested that the  
image could not be found in the cache, and the image had to either be loaded  
from flash or obtained via the network (for dynamic images). It is considered a  
RAM Cache Miss even if the image is subsequently found in flash cache.  
Items in Cache (RAM)  
Flash Current Size  
The number of images that are currently stored in the RAM cache.  
The maximum flash space allocated for image caching. Flash space is used for  
caching only when there is not enough available memory in the RAM cache for  
a newly requested image (it is used only for dynamic images).  
Flash Hit Rate  
The percentage of image requests (dynamic only) that are satisfied by  
accessing the flash cache.  
100 * (# of flash cache hits) / (# of flash cache hits + # of flash cache misses)  
# of flash cache hits - # of times a dynamic image could not be found in RAM  
cache but was found in flash cache  
# of flash cache misses - # of times a dynamic image could not be found in  
either RAM or flash cache. RAM cache hits are not relevant in this calculation.  
Items in Cache (Flash)  
The number of images that are currently stored in the Flash cache.  
Setting the image cache  
In the Protected Setup page:  
1. Press the Cache button in the Protected Setup Navigation Buttons section. This opens the Image  
Cache page.  
2. Set the cache expiration in the field Flash/RAM Cache Expires. The Up and Down arrows increment  
through the available time frames.  
3. Press the Enable button to turn on image caching. The button appears illuminated when enabled.  
You can allocate Flash memory for image caching, but RAM cache is always enabled.  
Select the Up and Down arrows for the field Flash Cache Size to increase or reduce the amount of Flash  
memory used; the maximum amount of flash that can be allocated for caching is 75% of available flash.  
83  
5" Modero Widescreen Touch Panel  
 
Firmware Pages and Descriptions  
Clearing the image cache  
In the Protected Setup page:  
1. Press the Cache button in the Protected Setup Navigation Buttons section. This opens the Image  
Cache page.  
2. Press Clear Cache. This clears all image cache currently stored on the panel (both Flash and  
RAM).  
Checking image cache status  
In the Protected Setup page:  
Press the Cache button in the Protected Setup Navigation Buttons section. This opens the Image Cache  
page. All status information is located in the Image Cache Status section of the page.  
Password Settings Page  
The options on the Password Settings page allow you to assign the passwords required for users to access  
the Protected Setup page (FIG. 73).  
FIG. 73 Password Setttings page  
Features on this page include:  
84  
5" Modero Widescreen Touch Panel  
       
Firmware Pages and Descriptions  
Password Settings Page  
Back:  
Saves all changes and returns to the previous page.  
Connection Status icon:  
The icon in the upper-right corner of each Setup page shows online/offline state  
of the panel to the master.  
• Bright red - disconnected  
• Bright green - connected. Blinks when a blink message is received to dark  
green every 5 seconds for half a second then go back to bright green.  
• Bright yellow - panel missed a blink message from the master. It will remain  
yellow for 3 missed blink messages and then turn red. It will return to green  
when a blink message is received.  
Note: a Lock appears on the icon if the panel is connected to a secured NetLinx  
Master.  
In Panel Password  
Change:  
Accesses the alphanumeric values associated to particular password sets.  
• The PASSWORD 1, 2, 3, 4 and 5 (protected) buttons open a keyboard to  
enter alphanumeric values associated to the selected password group.  
Note: Clearing Password #5 removes the need to enter a password before  
accessing the Protected Setup page.  
85  
5" Modero Widescreen Touch Panel  
Firmware Pages and Descriptions  
Tools  
The Tools button provides a menu to select either the Panel Logs Page section on page 86, the Panel  
options to access that page.  
FIG. 74 Tools menu  
Panel Logs Page  
The options on the Panel Logs page allow you to view and track the connection history of the panel  
FIG. 75 Panel Logs page  
86  
5" Modero Widescreen Touch Panel  
     
Firmware Pages and Descriptions  
Features on this page include:  
Panel Logs Page  
Back:  
Saves all changes and returns to the previous page.  
Connection Status icon:  
The icon in the upper-right corner of each Setup page shows online/offline state  
of the panel to the master.  
• Bright red - disconnected  
• Bright green - connected. Blinks when a blink message is received to dark  
green every 5 seconds for half a second then go back to bright green.  
• Bright yellow - panel missed a blink message from the master. It will remain  
yellow for 3 missed blink messages and then turn red. It will return to green  
when a blink message is received.  
Note: a Lock appears on the icon if the panel is connected to a secured NetLinx  
Master.  
Connection Logs  
Clear  
A history of all connections, attempts, and failures for the panel.  
Clears the Connection Logs history.  
Refresh  
Refreshes the Connection Logs history.  
Page  
Indicates the current page of the Connection Logs.  
Use the Up and Down arrows to move from one page to the next.  
Checking the Panel Connection Logs  
1. Press the Tools button in the Protected Setup Navigation Buttons section. This opens the Tools  
menu.  
2. Within the Tools menu, press the Panel Logs button. All connection data is contained in the section  
Connection Logs.  
Refreshing the Panel Connections Log  
1. Press the Tools button in the Protected Setup Navigation Buttons section. This opens the Tools  
menu.  
2. Within the Tools menu, press the Panel Logs button.  
3. Push the Refresh button.  
Clearing the Panel Connections Log  
1. Press the Tools button in the Protected Setup Navigation Buttons section. This opens the Tools  
menu.  
2. Within the Tools menu, press the Panel Logs button.  
3. Push the Clear button.  
4. Confirm your selection.  
87  
5" Modero Widescreen Touch Panel  
     
Firmware Pages and Descriptions  
Panel Statistics Page  
The options on the Panel Statistics page allow you to track the connection status for the panel. The Panel  
Statistics page tracks ICSP messages, Blink messages, and Ethernet connection statistics (FIG. 76).  
FIG. 76 Panel Statistics page  
Features on this page include:  
Panel Statistics Page  
Back:  
Saves all changes and returns to the previous page.  
Connection Status icon: The icon in the upper-right corner of each Setup page shows online/offline state of  
the panel to the master.  
• Bright red - disconnected  
• Bright green - connected. Blinks when a blink message is received to dark green  
every 5 seconds for half a second then go back to bright green.  
• Bright yellow - panel missed a blink message from the master. It will remain  
yellow for 3 missed blink messages and then turn red. It will return to green  
when a blink message is received.  
Note: a Lock appears on the icon if the panel is connected to a secured NetLinx  
Master.  
ICSP Messages  
Total  
Messages sent between the master and the touch panel; it is the protocol they use  
to communicate to each other.  
• Received - The total ICSP messages received by the panel.  
• Processed - The total ICSP messages processed by the panel.  
• Dropped - The total ICSP messages dropped by the panel.  
Last 15 Minutes  
• Received - The total ICSP messages received by the panel in the last 15  
minutes.  
• Processed - The total ICSP messages processed by the panel in the last 15  
minutes.  
• Dropped - The total ICSP messages dropped by the panel in the last 15 minutes.  
The master sends this message once every 5 seconds to all connected devices.  
Blink Messages  
Panel Statistics Page (Cont.)  
88  
5" Modero Widescreen Touch Panel  
   
Firmware Pages and Descriptions  
Total  
• Received - The total Blink messages received by the panel.  
• Missed - The total Blink messages missed by the panel.  
• Received - The total Blink messages received by the panel in the last 15 minutes.  
• Missed - The total Blink messages missed by the panel in the last 15 minutes.  
The Ethernet connection statistics for the panel.  
Last 15 Minutes  
Ethernet Statistics  
Clear  
Clears all panel connection statistics.  
Refresh  
Refreshes all panel connection statistics.  
Checking the Panel Statistics  
1. Press the Tools button in the Protected Setup Navigation Buttons section. This opens the Tools  
menu.  
2. Within the Tools menu, press the Panel Statistics button. All connection statistics are contained on  
this page, e.g., Received, Processed, and Dropped ICSP Messages.  
Refreshing the Panel Statistics  
1. Press the Tools button in the Protected Setup Navigation Buttons section. This opens the Tools  
menu.  
2. Within the Tools menu, press the Panel Statistics button.  
3. Push the Refresh button.  
Clearing the Panel Statistics  
1. Press the Tools button in the Protected Setup Navigation Buttons section. This opens the Tools  
menu.  
2. Within the Tools menu, press the Panel Statistics button.  
3. Push the Clear button.  
4. Confirm your selection.  
89  
5" Modero Widescreen Touch Panel  
     
Firmware Pages and Descriptions  
Connection Utility Page  
The options on the Connection Utility page allow you to utilize your panel as a site survey tool. While in  
this page, move around your wireless network coverage area and see if there are any weak points within  
the spaces between your WAPs (FIG. 77).  
FIG. 77 Connection Utility page  
Features on this page include:  
Connection Utility Page  
Close:  
Closes the Connection Utility popup.  
Connection Status icon:  
The icon in the upper-right corner of the utility provides a constant visual i  
indication of current connection status.  
A message is sent to the master once per second and expects a response.  
• If it is received the button stays green.  
• If it is missed the button goes yellow.  
• After three misses (3 seconds) it will go red until a response from the master  
is received, and then it will be green again.  
Once per second, a user can know whether they are standing in a good  
wireless area (all green), an area of limited coverage (lots of yellow, some  
green, some red), or an area with no coverage (all red).  
Connection Information  
Master IP  
The IP Address for the connected master.  
The IP Address for the panel.  
Panel IP  
Connection Statistics  
Messages Sent  
The number of messages sent from the panel to the master.  
Responses Received  
Responses Missed  
The number of responses the panel has received from the master.  
The number of expected responses from the master to the panel missed.  
90  
5" Modero Widescreen Touch Panel  
   
Firmware Pages and Descriptions  
Using the Connection Utility  
1. Press the Tools button in the Protected Setup Navigation Buttons section. This opens the Tools  
menu.  
2. Within the Tools menu, press the Connection Utility button. This launches the Connection Utility  
popup.  
3. Move the panel within your network. The Connection Information notes the IP of the connected  
master and the IP of your panel. The Connection Statistics show the current quality of the panel  
connection.  
4. Push Close when you are done using the site survey tool.  
Secondary Connection Page  
The Secondary Connection page sets the communication information for an installed wireless interface  
card. The NXD-CV5 Touch panel is not enabled for wireless communication and therefore, this page is  
not user-editable.  
91  
5" Modero Widescreen Touch Panel  
   
Firmware Pages and Descriptions  
92  
5" Modero Widescreen Touch Panel  
Programming  
Programming  
You can program the touch panel, using the commands in this section, to perform a wide variety of  
operations using Send_Commands and variable text commands.  
A device must first be defined in the NetLinx programming language with values for the Device:  
Port: System (in all programming examples - Panel is used in place of these values and represents all  
Modero panels).  
Verify you are using the latest NetLinx Master and Modero firmware.  
Verify you are using the latest version of NetLinx Studio and TPD4.  
Button Assignments  
• Button Channel Range: 1 - 4000 Button push and Feedback (per address port)  
• Button Variable Text range: 1 - 4000 (per address port)  
• Button States Range: 1 - 256  
(0 = All states, for General buttons 1 = Off state and 2 = On state).  
• Level Range: 1 - 600 (Default level value 0 - 255, can be set up to 1 - 65535)  
• Address port Range: 1 - 100  
These button assignments can only be adjusted in TPD4 and not on the panels  
themselves.  
Page Commands  
These Page Commands are used in NetLinx Programming Language and are case insensitive.  
Page Commands  
@APG  
Add the popup page to a group if it does not already exist. If the new popup is added to a  
group which has a popup displayed on the current page along with the new pop-up, the  
displayed popup will be hidden and the new popup will be displayed.  
Add a specific  
popup page to a  
specified popup  
group.  
Syntax:  
"'@APG-<popup page name>;<popup group name>'"  
Variable:  
popup page name = 1 - 50 ASCII characters. Name of the popup page.  
popup group name = 1 - 50 ASCII characters. Name of the popup group.  
Example:  
SEND_COMMAND Panel,"'@APG-Popup1;Group1'"  
Adds the popup page ’Popup1’ to the popup group ’Group1’.  
@CPG  
Syntax:  
Clear all popup  
pages from  
specified popup  
group.  
"'@CPG-<popup group name>'"  
Variable:  
popup group name = 1 - 50 ASCII characters. Name of the popup group.  
Example:  
SEND_COMMAND Panel,"'@CPG-Group1'"  
Clears all popup pages from the popup group ’Group1’.  
93  
5" Modero Widescreen Touch Panel  
     
Programming  
Page Commands (Cont.)  
@DPG  
Syntax:  
Delete a specific  
popup page from  
specified popup  
group if it exists.  
"'@DPG-<popup page name>;<popup group name>'"  
Variable:  
popup page name = 1 - 50 ASCII characters. Name of the popup page.  
popup group name = 1 - 50 ASCII characters. Name of the popup group.  
Example:  
SEND_COMMAND Panel,"'@DPG-Popup1;Group1'"  
Deletes the popup page ’Popup1’ from the popup group ’Group1’.  
@PDR  
If the flag is set, the popup will return to its default location on show instead of its last drag  
location.  
Set the popup  
location reset flag. Syntax:  
"'@PDR-<popup page name>;<reset flag>'"  
Variable:  
popup page name = 1 - 50 ASCII characters. Name of the page the popup is displayed  
On.  
reset flag = 1 = Enable reset flag  
0 = Disable reset flag  
Example:  
SEND_COMMAND Panel,"'@PDR-Popup1;1'"  
Popup1 will return to its default location when turned On.  
Syntax:  
@PHE  
Set the hide effect  
for the specified  
popup page to the  
named hide effect.  
"'@PHE-<popup page name>;<hide effect name>'"  
Variable:  
popup page name = 1 - 50 ASCII characters. Name of the page the popup is displayed  
On.  
hide effect name = Refers to the popup effect names being used.  
Example:  
SEND_COMMAND Panel,"'@PHE-Popup1;Slide to Left'"  
Sets the Popup1 hide effect name to ’Slide to Left’.  
@PHP  
Only 1 coordinate is ever needed for an effect; however, the command will specify both.  
This command sets the location at which the effect will end at.  
Set the hide effect  
position.  
Syntax:  
"'@PHP-<popup page name>;<x coordinate>,<y coordinate>'"  
Variable:  
popup page name = 1 - 50 ASCII characters. Name of the page the popup is displayed  
On.  
Example:  
SEND_COMMAND Panel,"'@PHP-Popup1;75,0'"  
Sets the Popup1 hide effect x-coordinate value to 75 and the y-coordinate value to 0.  
@PHT  
Syntax:  
Set the hide effect  
time for the  
specified popup  
page.  
"'@PHT-<popup page name>;<hide effect time>'"  
Variable:  
popup page name = 1 - 50 ASCII characters. Name of the page the popup is displayed  
On.  
hide effect time = Given in 1/10ths of a second.  
Example:  
SEND_COMMAND Panel,"'@PHT-Popup1;50'"  
Sets the Popup1 hide effect time to 5 seconds.  
94  
5" Modero Widescreen Touch Panel  
Programming  
Page Commands (Cont.)  
@PPA  
If the page name is empty, the current page is used. Same as the ’Clear Page’ command  
in TPDesign4.  
Close all popups  
on a specified  
page.  
Syntax:  
"'@PPA-<page name>'"  
Variable:  
page name = 1 - 50 ASCII characters. Name of the page the popup is displayed On.  
Example:  
SEND_COMMAND Panel,"'@PPA-Page1'"  
Close all popups on Page1.  
@PPF  
If the page name is empty, the current page is used (see example 2). If the popup page is  
part of a group, the whole group is deactivated. This command works in the same way as  
the ’Hide Popup’ command in TPDesign4.  
Deactivate a  
specific popup  
page on either a  
specified page or  
the current page.  
Syntax:  
"'@PPF-<popup page name>;<page name>'"  
Variable:  
popup page name = 1 - 50 ASCII characters. Name of the popup page.  
page name = 1 - 50 ASCII characters. Name of the page the popup is displayed On.  
Example:  
SEND_COMMAND Panel,"'@PPF-Popup1;Main'"  
Deactivates the popup page ’Popup1’ on the Main page.  
Example 2:  
SEND_COMMAND Panel,"'@PPF-Popup1'"  
Deactivates the popup page ’Popup1’ on the current page.  
@PPG  
If the page name is empty, the current page is used (see example 2). Toggling refers to the  
activating/deactivating (On/Off) of a popup page. This command works in the same way  
as the ’Toggle Popup’ command in TPDesign4.  
Toggle a  
specific popup  
page on either a  
specified page or  
the current page.  
Syntax:  
"'@PPG-<popup page name>;<page name>'"  
Variable:  
popup page name = 1 - 50 ASCII characters. Name of the popup page.  
page name = 1 - 50 ASCII characters. Name of the page the popup is displayed On.  
Example:  
SEND_COMMAND Panel,"'@PPG-Popup1;Main'"  
Toggles the popup page ’Popup1’ on the ’Main’ page from one state to another (On/Off).  
Example 2:  
SEND_COMMAND Panel,"'@PPG-Popup1'"  
Toggles the popup page ’Popup1’ on the current page from one state to another (On/Off).  
@PPK  
Kill refers to the deactivating (Off) of a popup window from all pages. If the pop-up page is  
part of a group, the whole group is deactivated. This command works in the same way as  
the 'Clear Group' command in TPDesign 4.  
Kill a specific  
popup page from  
all pages.  
Syntax:  
"'@PPK-<popup page name>'"  
Variable:  
popup page name = 1 - 50 ASCII characters. Name of the popup page.  
Example:  
SEND_COMMAND Panel,"'@PPK-Popup1'"  
Kills the popup page ’Popup1’ on all pages.  
95  
5" Modero Widescreen Touch Panel  
Programming  
Page Commands (Cont.)  
@PPM  
A Modal popup page, when active, only allows you to use the buttons and features on that  
popup page. All other buttons on the panel page are inactivated.  
Set the modality  
of a specific  
popup page to  
Modal or  
Syntax:  
"'@PPM-<popup page name>;<mode>'"  
Variable:  
NonModal.  
popup page name = 1 - 50 ASCII characters. Name of the popup page.  
mode = NONMODAL converts a previously Modal popup page to a NonModal.  
MODAL converts a previously NonModal popup page to Modal.  
modal = 1 and non-modal = 0  
Example:  
SEND_COMMAND Panel,"'@PPM-Popup1;Modal'"  
Sets the popup page ’Popup1’ to Modal.  
SEND_COMMAND Panel,"'@PPM-Popup1;1'"  
Sets the popup page ’Popup1’ to Modal.  
@PPN  
If the page name is empty, the current page is used (see example 2). If the popup page is  
already on, do not re-draw it. This command works in the same way as the ’Show Popup’  
command in TPDesign4.  
Activate a  
specific popup  
page to launch on Syntax:  
either a specified  
"'@PPN-<popup page name>;<page name>'"  
page or the  
current page.  
Variable:  
popup page name = 1 - 50 ASCII characters. Name of the popup page.  
page name = 1 - 50 ASCII characters. Name of the page the popup is displayed On.  
Example:  
SEND_COMMAND Panel,"'@PPN-Popup1;Main'"  
Activates ’Popup1’ on the ’Main’ page.  
Example 2:  
SEND_COMMAND Panel,"'@PPN-Popup1'"  
Activates the popup page ’Popup1’ on the current page.  
If timeout is empty, popup page will clear the timeout.  
Syntax:  
@PPT  
Set a specific  
popup page to  
timeout within a  
specified time.  
"'@PPT-<popup page name>;<timeout>'"  
Variable:  
popup page name = 1 - 50 ASCII characters. Name of the popup page.  
timeout = Timeout duration in 1/10ths of a second.  
Example:  
SEND_COMMAND Panel,"'@PPT-Popup1;30'"  
Sets the popup page ’Popup1’ to timeout within 3 seconds.  
@PPX  
This command works in the same way as the 'Clear All' command in TPDesign 4.  
Close all popups  
on all pages.  
Syntax:  
"'@PPX'"  
Example:  
SEND_COMMAND Panel,"'@PPX'"  
Close all popups on all pages.  
96  
5" Modero Widescreen Touch Panel  
Programming  
Page Commands (Cont.)  
@PSE  
Syntax:  
Set the show  
effect for the  
specified popup  
page to the  
named show  
effect.  
"'@PSE-<popup page name>;<show effect name>'"  
Variable:  
popup page name = 1 - 50 ASCII characters. Name of the page the popup is displayed  
On.  
show effect name = Refers to the popup effect name being used.  
Example:  
SEND_COMMAND Panel,"'@PSE-Popup1;Slide from Left'"  
Sets the Popup1 show effect name to ’Slide from Left’.  
@PSP  
Only 1 coordinate is ever needed for an effect; however, the command will specify both.  
This command sets the location at which the effect will begin at.  
Set the show  
effect position.  
Syntax:  
"'@PSP-<popup page name>;<x coordinate>,<y coordinate>'"  
Variable:  
popup page name = 1 - 50 ASCII characters. Name of the page the popup is displayed  
On.  
Example:  
SEND_COMMAND Panel,"'@PSP-Popup1;100,0'"  
Sets the Popup1 show effect x-coordinate value to 100 and the y-coordinate value to 0.  
@PST  
Syntax:  
Set the show  
effect time for the  
specified popup  
page.  
"'@PST-<popup page name>;<show effect time>'"  
Variable:  
popup page name = 1 - 50 ASCII characters. Name of the page the popup is displayed  
On.  
show effect time = Given in 1/10ths of a second.  
Example:  
SEND_COMMAND Panel,"'@PST-Popup1;50'"  
Sets the Popup1 show effect time to 5 seconds.  
PAGE  
Flips to a page with a specified page name. If the page is currently active, it will not redraw  
the page.  
Flip to a specified  
page.  
Syntax:  
"'PAGE-<page name>'"  
Variable:  
page name = 1 - 50 ASCII characters. Name of the page the popup is displayed On.  
Example:  
SEND_COMMAND Panel,"'PAGE-Page1'"  
Flips to page1.  
97  
5" Modero Widescreen Touch Panel  
Programming  
Page Commands (Cont.)  
PPOF  
If the page name is empty, the current page is used (see example 2). If the popup page is  
part of a group, the whole group is deactivated. This command works in the same way as  
the ’Hide Popup’ command in TPDesign4.  
Deactivate a  
specific popup  
page on either a  
specified page or  
the current page.  
Syntax:  
"'PPOF-<popup page name>;<page name>'"  
Variable:  
popup page name = 1 - 50 ASCII characters. Name of the popup page.  
page name = 1 - 50 ASCII characters. Name of the page the popup is displayed On.  
Example:  
SEND_COMMAND Panel,"'PPOF-Popup1;Main'"  
Deactivates the popup page ’Popup1’ on the Main page.  
Example 2:  
SEND_COMMAND Panel,"'PPOF-Popup1'"  
Deactivates the popup page ’Popup1’ on the current page.  
PPOG  
If the page name is empty, the current page is used (see example 2). Toggling refers to the  
activating/deactivating (On/Off) of a popup page. This command works in the same way  
as the ’Toggle Popup’ command in TPDesign4.  
Toggle a specific  
popup page on  
either a specified Syntax:  
page or the  
"'PPOG-<popup page name>;<page name>'"  
current page.  
Variable:  
popup page name = 1 - 50 ASCII characters. Name of the popup page.  
page name = 1 - 50 ASCII characters. Name of the page the popup is displayed On.  
Example:  
SEND_COMMAND Panel,"'PPOG-Popup1;Main'"  
Toggles the popup page ’Popup1’ on the Main page from one state to another (On/Off).  
Example 2:  
SEND_COMMAND Panel,"'PPOG-Popup1'"  
Toggles the popup page ’Popup1’ on the current page from one state to another (On/Off).  
PPON  
If the page name is empty, the current page is used (see example 2). If the popup page is  
already On, do not re-draw it. This command works in the same way as the ’Show Popup’  
command in TPDesign4.  
Activate a  
specific popup  
page to launch on Syntax:  
either a specified  
"'PPON-<popup page name>;<page name>'"  
page or the  
current page.  
Variable:  
popup page name = 1 - 50 ASCII characters. Name of the popup page.  
page name = 1 - 50 ASCII characters. Name of the page the popup is displayed On.  
Example:  
SEND_COMMAND Panel,"'PPON-Popup1; Main'"  
Activates the popup page ’Popup1’ on the Main page.  
Example 2:  
SEND_COMMAND Panel,"'PPON-Popup1'"  
Activates the popup page ’Popup1’ on the current page.  
98  
5" Modero Widescreen Touch Panel  
Programming  
Programming Numbers  
The following information provides the programming numbers for colors, fonts, and borders.  
Colors can be used to set the colors on buttons, sliders, and pages. The lowest color number represents  
the lightest color-specific display; the highest number represents the darkest display. For example, 0  
represents light red, and 5 is dark red.  
RGB triplets and names for basic 88 colors  
RGB Values for all 88 Basic Colors  
Index No. Name  
Very Light Red  
Red  
255  
223  
191  
159  
127  
95  
255  
223  
191  
159  
127  
95  
255  
223  
191  
159  
127  
95  
128  
112  
96  
80  
64  
48  
0
Green  
0
Blue  
0
00  
01  
02  
03  
04  
05  
06  
07  
08  
09  
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
25  
26  
27  
28  
29  
30  
31  
32  
33  
34  
35  
Light Red  
0
0
Red  
0
0
Medium Red  
Dark Red  
0
0
0
0
Very Dark Red  
Very Light Orange  
Light Orange  
Orange  
0
0
128  
112  
96  
0
0
0
Medium Orange  
Dark Orange  
Very Dark Orange  
Very Light Yellow  
Light Yellow  
Yellow  
80  
0
64  
0
48  
0
255  
223  
191  
159  
127  
95  
0
0
0
Medium Yellow  
Dark Yellow  
Very Dark Yellow  
Very Light Lime  
Light Lime  
0
0
0
255  
223  
191  
159  
127  
95  
0
0
Lime  
0
Medium Lime  
Dark Lime  
0
0
Very Dark Lime  
Very Light Green  
Light Green  
Green  
0
255  
223  
191  
159  
127  
95  
0
0
0
0
0
Medium Green  
Dark Green  
Very Dark Green  
Very Light Mint  
Light Mint  
0
0
0
0
0
0
0
255  
223  
191  
159  
127  
95  
128  
112  
96  
80  
64  
48  
0
Mint  
0
Medium Mint  
Dark Mint  
0
0
Very Dark Mint  
0
99  
5" Modero Widescreen Touch Panel  
     
Programming  
RGB Values for all 88 Basic Colors (Cont.)  
Index No. Name  
Very Light Cyan  
Red  
Green  
255  
223  
191  
159  
127  
95  
128  
112  
96  
80  
64  
48  
0
Blue  
255  
223  
191  
159  
127  
95  
36  
37  
38  
39  
40  
41  
42  
43  
44  
45  
46  
47  
48  
49  
50  
51  
52  
53  
54  
55  
56  
57  
58  
59  
60  
61  
62  
63  
64  
65  
66  
67  
68  
69  
70  
71  
72  
73  
74  
75  
76  
77  
78  
79  
0
Light Cyan  
Cyan  
0
0
Medium Cyan  
Dark Cyan  
Very Dark Cyan  
Very Light Aqua  
Light Aqua  
Aqua  
0
0
0
0
255  
223  
191  
159  
127  
95  
0
0
Medium Aqua  
Dark Aqua  
Very Dark Aqua  
Very Light Blue  
Light Blue  
0
0
0
0
255  
223  
191  
159  
127  
95  
0
0
Blue  
0
0
Medium Blue  
Dark Blue  
0
0
0
0
Very Dark Blue  
Very Light Purple  
Light Purple  
Purple  
0
0
128  
112  
96  
80  
64  
48  
255  
223  
191  
159  
127  
95  
255  
223  
191  
159  
127  
95  
255  
238  
204  
170  
136  
102  
187  
153  
0
255  
223  
191  
159  
127  
95  
0
0
Medium Purple  
Dark Purple  
Very Dark Purple  
Very Light Magenta  
Light Magenta  
Magenta  
0
0
0
0
255  
223  
191  
159  
127  
95  
0
0
Medium Magenta  
Dark Magenta  
Very Dark Magenta  
Very Light Pink  
Light Pink  
0
0
0
0
128  
112  
96  
0
Pink  
0
Medium Pink  
Dark Pink  
0
80  
0
64  
Very Dark Pink  
White  
0
48  
255  
238  
204  
170  
136  
102  
187  
153  
255  
238  
204  
170  
136  
102  
187  
153  
Grey1  
Grey3  
Grey5  
Grey7  
Grey9  
Grey4  
Grey6  
100  
5" Modero Widescreen Touch Panel  
Programming  
RGB Values for all 88 Basic Colors (Cont.)  
Index No. Name  
Red  
Green  
119  
85  
Blue  
119  
85  
80  
81  
82  
83  
84  
85  
86  
87  
255  
Grey8  
119  
85  
51  
34  
221  
68  
17  
0
Grey10  
Grey12  
Grey13  
Grey2  
51  
51  
34  
34  
221  
68  
221  
68  
Grey11  
Grey14  
Black  
17  
17  
0
0
TRANSPARENT  
99  
53  
99  
Font styles and ID numbers  
Font styles can be used to program the text fonts on buttons, sliders, and pages. The following chart  
shows the default font type and their respective ID numbers generated by TPDesign4.  
Default Font Styles and ID Numbers  
Font ID # Font type  
Size  
9
Font ID # Font type  
Size  
9
1
Courier New  
Courier New  
Courier New  
Courier New  
Courier New  
Courier New  
Courier New  
Courier New  
AMX Bold  
19  
20  
21  
22  
23  
24  
25  
26  
27  
28  
29  
Arial  
2
12  
18  
26  
32  
18  
26  
34  
14  
20  
36  
Arial  
10  
12  
14  
16  
18  
20  
24  
36  
10  
8
3
Arial  
4
Arial  
5
Arial  
6
Arial  
7
Arial  
8
Arial  
9
Arial  
10  
11  
AMX Bold  
Arial Bold  
Arial Bold  
AMX Bold  
32 - Variable Fonts start at 32.  
You must import fonts into a TPDesign4 project file. The font ID numbers are  
assigned by TPDesign4. These values are also listed in the  
Generate Programmer’s Report.  
101  
5" Modero Widescreen Touch Panel  
   
Programming  
Border styles and Programming numbers  
Border styles can be used to program borders on buttons, sliders, and popup pages.  
Border Styles and Programming Numbers  
No.  
0-1  
2
Border styles  
No border  
Single line  
Double line  
Quad line  
No.  
Border styles  
10-11 Picture frame  
12  
20  
21  
Double line  
Bevel-S  
3
4
Bevel-M  
5-6  
7
Circle 15  
22-23 Circle 15  
Single line  
Double line  
Quad line  
24-27 Neon inactive-S  
40-41 Diamond 55  
8
9
The TPDesign4 Touch Panel Design program has pre-set border styles that are user selectable.  
You cannot use the following number values for programming purposes when changing border styles.  
TPD4 border styles can ONLY be changed by using the name.  
TPD4 Border Styles by Name  
No.  
1
Border styles  
None  
No.  
22  
23  
24  
25  
26  
27  
28  
29  
30  
31  
32  
33  
34  
35  
36  
37  
38  
39  
40  
41  
42  
Border styles  
Circle 155  
2
AMX Elite -L  
AMX Elite -M  
AMX Elite -S  
Bevel -L  
Circle 165  
3
Circle 175  
4
Circle 185  
5
Circle 195  
6
Bevel -M  
Cursor Bottom  
Cursor Bottom with Hole  
Cursor Top  
7
Bevel -S  
8
Circle 15  
9
Circle 25  
Cursor Top with Hole  
Cursor Left  
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
21  
Circle 35  
Circle 45  
Cursor Left with Hole  
Cursor Right  
Cursor Right with Hole  
Custom Frame  
Diamond 15  
Circle 55  
Circle 65  
Circle 75  
Circle 85  
Circle 95  
Diamond 25  
Circle 105  
Circle 115  
Circle 125  
Circle 135  
Circle 145  
Diamond 35  
Diamond 45  
Diamond 55  
Diamond 65  
Diamond 75  
102  
5" Modero Widescreen Touch Panel  
     
Programming  
TPD4 Border Styles by Name (Cont.)  
No.  
43  
44  
45  
46  
47  
48  
49  
50  
51  
52  
53  
54  
55  
56  
57  
58  
59  
60  
61  
62  
63  
64  
65  
66  
67  
68  
69  
70  
71  
72  
73  
74  
75  
76  
77  
78  
79  
80  
81  
82  
83  
84  
Border styles  
Diamond 85  
No.  
85  
Border styles  
Menu Bottom Rounded 65  
Menu Bottom Rounded 75  
Menu Bottom Rounded 85  
Menu Bottom Rounded 95  
Menu Bottom Rounded 105  
Menu Bottom Rounded 115  
Menu Bottom Rounded 125  
Menu Bottom Rounded 135  
Menu Bottom Rounded 145  
Menu Bottom Rounded 155  
Menu Bottom Rounded 165  
Menu Bottom Rounded 175  
Menu Bottom Rounded 185  
Menu Bottom Rounded 195  
Menu Top Rounded 15  
Menu Top Rounded 25  
Menu Top Rounded 35  
Menu Top Rounded 45  
Menu Top Rounded 55  
Menu Top Rounded 65  
Menu Top Rounded 75  
Menu Top Rounded 85  
Menu Top Rounded 95  
Menu Top Rounded 105  
Menu Top Rounded 115  
Menu Top Rounded 125  
Menu Top Rounded 135  
Menu Top Rounded 145  
Menu Top Rounded 155  
Menu Top Rounded 165  
Menu Top Rounded 175  
Menu Top Rounded 185  
Menu Top Rounded 195  
Menu Right Rounded 15  
Menu Right Rounded 25  
Menu Right Rounded 35  
Menu Right Rounded 45  
Menu Right Rounded 55  
Menu Right Rounded 65  
Menu Right Rounded 75  
Menu Right Rounded 85  
Menu Right Rounded 95  
Diamond 95  
86  
Diamond 105  
87  
Diamond 115  
88  
Diamond 125  
89  
Diamond 135  
90  
Diamond 145  
91  
Diamond 155  
92  
Diamond 165  
93  
Diamond 175  
94  
Diamond 185  
95  
Diamond 195  
96  
Double Bevel -L  
Double Bevel -M  
Double Bevel -S  
Double Line  
97  
98  
99  
100  
101  
102  
103  
104  
105  
106  
107  
108  
109  
110  
111  
112  
113  
114  
115  
116  
117  
118  
119  
120  
121  
122  
123  
124  
125  
126  
Fuzzy  
Glow-L  
Glow-S  
Help Down  
Neon Active -L  
Neon Active -S  
Neon Inactive -L  
Neon Inactive -S  
Oval H 60x30  
Oval H 100x50  
Oval H 150x75  
Oval H 200x100  
Oval V 30x60  
Oval V 50x100  
Oval V 75x150  
Oval V 100x200  
Picture Frame  
Quad Line  
Single Line  
Windows Style Popup  
Windows Style Popup (Status Bar)  
Menu Bottom Rounded 15  
Menu Bottom Rounded 25  
Menu Bottom Rounded 35  
Menu Bottom Rounded 45  
Menu Bottom Rounded 55  
103  
5" Modero Widescreen Touch Panel  
Programming  
TPD4 Border Styles by Name (Cont.)  
No.  
127  
128  
129  
130  
131  
132  
133  
134  
135  
136  
137  
138  
139  
140  
141  
142  
143  
144  
Border styles  
No.  
145  
146  
147  
148  
149  
150  
151  
152  
153  
154  
155  
Border styles  
Menu Right Rounded 105  
Menu Right Rounded 115  
Menu Right Rounded 125  
Menu Right Rounded 135  
Menu Right Rounded 145  
Menu Right Rounded 155  
Menu Right Rounded 165  
Menu Right Rounded 175  
Menu Right Rounded 185  
Menu Right Rounded 195  
Menu Left Rounded 15  
Menu Left Rounded 25  
Menu Left Rounded 35  
Menu Left Rounded 45  
Menu Left Rounded 55  
Menu Left Rounded 65  
Menu Left Rounded 75  
Menu Left Rounded 85  
Menu Left Rounded 95  
Menu Left Rounded 105  
Menu Left Rounded 115  
Menu Left Rounded 125  
Menu Left Rounded 135  
Menu Left Rounded 145  
Menu Left Rounded 155  
Menu Left Rounded 165  
Menu Left Rounded 175  
Menu Left Rounded 185  
Menu Left Rounded 195  
"^" Button Commands  
These Button Commands are used in NetLinx Studio and are case insensitive.  
All commands that begin with "^" have the capability of assigning a variable text address range and  
button state range. A device must first be defined in the NetLinx programming language with values  
for the Device: Port : System (in all programming examples - Panel is used in place of these values).  
Variable text ranges allow you to target 1 or more variable text channels in a single  
command.  
Button State ranges allow you to target 1 or more states of a variable text button with a single  
command.  
"." Character is used for the 'through' notation, also the "&" character is used for the 'And'  
notation.  
104  
5" Modero Widescreen Touch Panel  
 
Programming  
"^" Button Commands  
^ANI  
Syntax:  
Run a button  
animation  
(in 1/10 second).  
"'^ANI-<vt addr range>,<start state>,<end state>,<time>'"  
Variable:  
variable text address range = 1 - 4000.  
start state = Beginning of button state (0= current state).  
end state = End of button state.  
time = In 1/10 second intervals.  
Example:  
SEND_COMMAND Panel,"'^ANI-500,1,25,100'"  
Runs a button animation at text range 500 from state 1 to state 25 for 10 second.  
^APF  
Syntax:  
Add page flip  
action to a button  
if it does not  
"'^APF-<vt addr range>,<page flip action>,<page name>'"  
Variable:  
variable text address range = 1 - 4000.  
already exist.  
page flip action =  
Stan[dardPage] - Flip to standard page  
Prev[iousPage] - Flip to previous page  
Show[Popup] - Show Popup page  
Hide[Popup] - Hide Popup page  
Togg[lePopup] - Toggle popup state  
ClearG[roup] - Clear popup page group from all pages  
ClearP[age] - Clear all popup pages from a page with the  
specified page name  
ClearA[ll] - Clear all popup pages from all pages  
page name = 1 - 50 ASCII characters.  
Example:  
SEND COMMAND Panel,"'^APF-400,Stan,Main Page'"  
Assigns a button to a standard page flip with page name 'Main Page'.  
Syntax:  
^BAT  
Append  
non-unicode text.  
"'^BAT-<vt addr range>,<button states range>,<new text>'"  
Variable:  
variable text address range = 1 - 4000.  
button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons  
1 = Off state and 2 = On state).  
new text = 1 - 50 ASCII characters.  
Example:  
SEND_COMMAND Panel,"'^BAT-520,1,Enter City'"  
Appends the text 'Enter City' to the button’s OFF state.  
^BAU  
Same format as ^UNI.  
Append  
Syntax:  
unicode text.  
"'^BAU-<vt addr range>,<button states range>,<unicode text>'"  
Variable:  
variable text address range = 1 - 4000.  
button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons  
1 = Off state and 2 = On state).  
unicode text = 1 - 50 ASCII characters. Unicode characters must be entered in Hex  
format.  
Example:  
SEND_COMMAND Panel,"'^BAU-520,1,00770062'"  
Appends Unicode text '00770062' to the button’s OFF state.  
105  
5" Modero Widescreen Touch Panel  
Programming  
"^" Button Commands (Cont.)  
^BCB  
Only if the specified border color is not the same as the current color.  
Set the border  
color to the  
Note: Color can be assigned by color name (without spaces), number or R,G,B value  
(RRGGBB or RRGGBBAA).  
specified color.  
Syntax:  
"'^BCB-<vt addr range>,<button states range>,<color value>'"  
Variable:  
variable text address range = 1 - 4000.  
button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons  
1 = Off state and 2 = On state).  
information.  
Example:  
SEND_COMMAND Panel,"'^BCB-500.504&510,1,12'"  
Sets the Off state border color to 12 (Yellow). Colors can be set by Color Numbers, Color  
name, R,G,B,alpha colors (RRGGBBAA) and R, G & B colors values (RRGGBB).  
^BCF  
Only if the specified fill color is not the same as the current color.  
Set the fill color to Note: Color can be assigned by color name (without spaces), number or R,G,B value  
the specified  
color.  
(RRGGBB or RRGGBBAA).  
Syntax:  
"'^BCF-<vt addr range>,<button states range>,<color value>'"  
Variable:  
variable text address range = 1 - 4000.  
button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons  
1 = Off state and 2 = On state).  
information.  
Example:  
SEND_COMMAND Panel,"'^BCF-500.504&510.515,1,12'"  
SEND_COMMAND Panel,"'^BCF-500.504&510.515,1,Yellow'"  
SEND_COMMAND Panel,"'^BCF-500.504&510.515,1,#F4EC0A63''"  
SEND_COMMAND Panel,"'^BCF-500.504&510.515,1,#F4EC0A'"  
Sets the Off state fill color by color number. Colors can be set by Color Numbers, Color  
name, R,G,B,alpha colors (RRGGBBAA) and R, G & B colors values (RRGGBB).  
106  
5" Modero Widescreen Touch Panel  
Programming  
"^" Button Commands (Cont.)  
^BCT  
Only if the specified text color is not the same as the current color.  
Set the text color Note: Color can be assigned by color name (without spaces), number or R,G,B value  
to the specified  
color.  
(RRGGBB or RRGGBBAA).  
Syntax:  
"'^BCT-<vt addr range>,<button states range>,<color value>'"  
Variable:  
variable text address range = 1 - 4000.  
button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons  
1 = Off state and 2 = On state).  
information.  
Example:  
SEND_COMMAND Panel,"'^BCT-500.504&510,1,12'"  
Sets the Off state border color to 12 (Yellow). Colors can be set by Color Numbers, Color  
name, R,G,B,alpha colors (RRGGBBAA) and R, G & B colors values (RRGGBB).  
^BDO  
Determines what order each layer of the button is drawn.  
Syntax:  
Set the button  
draw order.  
"'^BDO-<vt addr range>,<button states range>,<1-5><1-5><1-5><1-  
5><1-5>'"  
Variable:  
variable text address range = 1 - 4000.  
button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons  
1 = Off state and 2 = On state).  
layer assignments = Fill Layer  
= 1  
Image Layer = 2  
Icon Layer = 3  
Text Layer = 4  
Border Layer = 5  
Note: The layer assignments are from bottom to top. The default draw order is 12345.  
Example:  
SEND_COMMAND Panel,"'^BDO-530,1&2,51432'"  
Sets the button’s variable text 530 ON/OFF state draw order (from bottom to top) to  
Border, Fill, Text, Icon, and Image.  
Example 2:  
SEND_COMMAND Panel,"'^BDO-1,0,12345'"  
Sets all states of a button back to its default drawing order.  
ONLY works on General-type buttons.  
^BFB  
Set the feedback Syntax:  
type of the button.  
"'^BFB-<vt addr range>,<feedback type>'"  
Variable:  
variable text address range = 1 - 4000.  
feedback type = (None, Channel, Invert, On (Always on), Momentary, and Blink).  
Example:  
SEND_COMMAND Panel,"'^BFB-500,Momentary'"  
Sets the Feedback type of the button to 'Momentary'.  
107  
5" Modero Widescreen Touch Panel  
 
Programming  
"^" Button Commands (Cont.)  
^BIM  
Syntax:  
Set the input  
mask for the  
specified address.  
"'^BIM-<vt addr range>,<input mask>'"  
Variable:  
variable text address range = 1 - 4000.  
input mask = Refer to theText Area Input Masking section on page 148 for character  
types.  
Example:  
SEND_COMMAND Panel,"'^BIM-500,AAAAAAAAAA'"  
Sets the input mask to ten ’A’ characters, that are required, to either a letter or digit  
(entry is required).  
^BLN  
The maximum number of lines to remove is 240. A value of 0 will display the incoming  
video signal unaffected. This command is used to scale non 4x3 video images into non  
4x3 video buttons.  
Set the number of  
lines removed  
equally from the  
top and bottom of  
a composite video  
signal.  
Syntax:  
"'^BLN-<vt addr range>,<button states range>,<number of lines>'"  
Variable:  
variable text address range = 1 - 4000.  
button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons  
1 = Off state and 2 = On state).  
number of lines = 0 - 240.  
Example:  
SEND_COMMAND Panel,"'^BLN-500,55'"  
Equally removes 55 lines from the top and 55 lines from the bottom of the video button.  
108  
5" Modero Widescreen Touch Panel  
   
Programming  
"^" Button Commands (Cont.)  
^BMC  
Note that the source is a single button state. Each state must be copied as a separate  
command. The <codes> section represents what attributes will be copied. All codes are  
2 char pairs that can be separated by comma, space, percent or just ran together.  
Button copy  
command.  
Copy attributes of Syntax:  
the source button  
"'^BMC-<vt addr range>,<button states range>,<source  
port>,<source address>,<source state>,<codes>'"  
to all the  
destination  
buttons.  
Variable:  
variable text address range = 1 - 4000.  
button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons  
1 = Off state and 2 = On state).  
source port = 1 - 100.  
source address = 1 - 4000.  
source state = 1 - 256.  
codes: BM - Picture/Bitmap  
BR - Border  
CB - Border Color  
CF - Fill Color  
CT - Text Color  
EC - Text effect color  
EF - Text effect  
FT - Font  
IC - Icon  
JB - Bitmap alignment  
JI - Icon alignment  
JT - Text alignment  
LN - Lines of video removed  
OP - Opacity  
SO - Button Sound  
TX - Text  
VI - Video slot ID  
WW - Word wrap on/off  
Example:  
SEND_COMMAND Panel,"'^BMC-425,1,1,500,1,BR'"  
or  
SEND_COMMAND Panel,"'^BMC-425,1,1,500,1,%BR'"  
Copies the OFF state border of button with a variable text address of 500 onto the OFF  
state border of button with a variable text address of 425.  
Example 2:  
SEND_COMMAND Panel,"'^BMC-150,1,1,315,1,%BR%FT%TX%BM%IC%CF%CT'"  
Copies the OFF state border, font, Text, bitmap, icon, fill color and text color of the button  
with a variable text address of 315 onto the OFF state border, font, Text, bitmap, icon, fill  
color and text color of the button with a variable text address of 150.  
109  
5" Modero Widescreen Touch Panel  
Programming  
"^" Button Commands (Cont.)  
^BMF  
Syntax:  
Set any/all button  
parameters by  
sending  
embedded codes  
and data.  
"'^BMF-<vt addr range>,<button states range>,<data>'"  
Variables:  
variable text address char array = 1 - 4000.  
button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons  
1 = Off state and 2 = On state).  
level range = 1 - 600 (level value is 1 - 65535).  
data:  
’%B<border style>’ = Set the border style name. See theBorder Styles and Programming  
’%B’,<border 0-27,40,41> = Set the borer style number. See theBorder Styles and  
’%DO<1-5><1-5><1-5><1-5><1-5> = Set the draw order. Listed from bottom to top.  
Refer to the ^BDO command on page 107 for more information.  
’%F’,<font 1-8,10,11,20-29,32-xx> = Set the font. See theDefault Font Styles and ID  
’%F<font 01-08,10,11,20-29,32-xx>’ = Set the font. See theDefault Font Styles and ID  
’%MI<mask image>’ = Set the mask image. Refer to the ^BMI command on page 112 for  
more information.  
’%T<text >’ = Set the text using ASCII characters (empty is clear).  
’%P<bitmap>’ = Set the picture/bitmap filename (empty is clear).  
’%I’,<icon 01-9900, 0-clear>’ = Set the icon using values of 01 - 9900 (icon numbers are  
assigned in the TPDesign4 Resource Manager tab - Slots section).  
’%I<icon 01-9900, 0-clear>’ = Set the icon using values of 01 - 9900 (icon numbers are  
assigned in the TPDesign4 Resource Manager tab - Slots section).  
’%J’,<alignment of text 1-9> = As shown the following telephone keypad alignment  
chart:  
0
1
4
7
3
6
9
2
5
8
Zero can be used for an absolute position  
’%JT<alignment of text 0-9>’ = As shown the above telephone keypad alignment chart,  
BUT the 0 (zero) is absolute and followed by ’,<left>,<top>’  
’%JB<alignment of bitmap/picture 0-9>’ = As shown the above telephone keypad  
alignment chart BUT the 0 (zero) is absolute and followed by ’,<left>,<top>’  
’%JI<alignment of icon 0-9>’ = As shown the above telephone keypad alignment chart,  
BUT the 0 (zero) is absolute and followed by ’,<left>,<top>’  
110  
5" Modero Widescreen Touch Panel  
 
Programming  
"^" Button Commands (Cont.)  
^BMF  
For some of these commands and values, refer to theRGB Values for all 88 Basic  
(Cont.)  
’%CF<on fill color>’ = Set Fill Color.  
’%CB<on border color>’ = Set Border Color.  
’%CT<on text color>’ = Set Text Color.  
’%SW<1 or 0>’ = Show/hide a button.  
’%SO<sound>’ = Set the button sound.  
’%EN<1 or 0>’ = Enable/disable a button.  
’%WW<1 or 0>’ = Word wrap On/Off.  
’%GH<bargraph hi>’ = Set the bargraph upper limit.  
’%GL<bargraph low>’ = Set the bargraph lower limit.  
’%GN<bargraph slider name>’ = Set the bargraph slider name/Joystick cursor name.  
’%GC<bargraph slider color>’ = Set the bargraph slider color/Joystick cursor color.  
’%GI<bargraph invert>’ = Set the bargraph invert/noninvert or joystick coordinate  
(0,1,2,3). See the ^GIV command on page 118 for more information.  
’%GU<bargraph ramp up>’ = Set the bargraph ramp up time in intervals of 1/10 second.  
’%GD<bargraph ramp down>’ = Set the bargraph ramp down time in 1/10 second.  
’%GG<bargraph drag increment> = Set the bargraph drag increment. Refer to the ^GDI  
command on page 118 for more information.  
’%VI<video ON/OFF>’ = Set the Video either ON (value=1) or OFF (value=0).  
’%OT<feedback type>’ = Set the Feedback (Output) Type to one of the following:  
None, Channel,Invert, ON (Always ON), Momentary, or Blink.  
’%SM’ = Submit a text for text area button.  
’%SF<1 or 0>’ = Set the focus for text area button.  
’%OP<0-255>’ = Set the button opacity to either Invisible (value=0) or Opaque  
(value=255).  
’%OP#<00-FF>’ = Set the button opacity to either Invisible (value=00) or Opaque  
(value=FF).  
’%UN<Unicode text>’ = Set the Unicode text. See the ^UNI section on page 123 for the  
text format.  
’%LN<0-240>’ = Set the lines of video being removed. See the ^BLN section on  
page 108 for more information.  
’%EF<text effect name>’ = Set the text effect.  
’%EC<text effect color>’ = Set the text effect color.  
’%ML<max length>’ = Set the maximum length of a text area.  
’%MK<input mask>’ = Set the input mask of a text area.  
’%VL<0-1>’ = Log-On/Log-Off the computer control connection  
’%VN<network name>’ = Set network connection name.  
’%VP<password>’ = Set the network connection password.  
Example:  
SEND_COMMAND Panel,"'^BMF-500,1,%B10%CFRed%CB Blue  
%CTBlack%Ptest.png'"  
Sets the button OFF state as well as the Border, Fill Color, Border Color, Text Color, and  
Bitmap.  
111  
5" Modero Widescreen Touch Panel  
Programming  
"^" Button Commands (Cont.)  
^BMI  
Mask image is used to crop a borderless button to a non-square shape. This is typically  
used with a bitmap.  
Set the button  
mask image.  
Syntax:  
"'^BMI-<vt addr range>,<button states range>,<mask image>'"  
Variable:  
variable text address range = 1 - 4000.  
button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons  
1 = Off state and 2 = On state).  
mask image = Graphic file used.  
Example:  
SEND_COMMAND Panel,"'^BMI-530,1&2,newMac.png'"  
Sets the button with variable text 530 ON/OFF state mask image to 'newmac.png'.  
^BML  
If this value is set to zero (0) there is no max length. The maximum length available is  
2000. This is only for a Text area input button and not for a Text area input masking button.  
Set the maximum  
length of the text  
area button.  
Syntax:  
"'^BML-<vt addr range>,<max length>'"  
Variable:  
variable text address range = 1 - 4000.  
max length = 2000 (0=no max length).  
Example:  
SEND_COMMAND Panel,"'^BML-500,20'"  
Sets the maximum length of the text area input button to 20 characters.  
Syntax:  
^BMP  
Assign a picture to  
those buttons with  
a defined address  
range.  
"'^BMP-<vt addr range>,<button states range>,<name of bitmap/  
picture>'"  
Variable:  
variable text address range = 1 - 4000.  
button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons  
1 = Off state and 2 = On state).  
name of bitmap/picture = 1 - 50 ASCII characters.  
Example:  
SEND_COMMAND Panel,"'^BMP-500.504&510.515,1,bitmap.png'"  
Sets the OFF state picture for the buttons with variable text ranges of 500-504 & 510-515.  
Syntax:  
^BNC  
Clear current  
TakeNote  
annotations.  
"'^BNC-<vt addr range>,<command value>'"  
Variable:  
variable text address range = 1 - 4000.  
command value = (0= clear, 1= clear all).  
Example:  
SEND_COMMAND Panel,"'^BNC-973,0'"  
Clears the annotation of the TakeNote button with variable text 973.  
112  
5" Modero Widescreen Touch Panel  
 
Programming  
"^" Button Commands (Cont.)  
^BNN  
Syntax:  
Set the TakeNote  
network name for  
the specified  
"'^BNN-<vt addr range>,<network name>'"  
Variable:  
variable text address range = 1 - 4000.  
network name = Use a valid IP Address.  
Example:  
Addresses.  
SEND_COMMAND Panel,"'^BNN-973,192.168.169.99'"  
Sets the TakeNote button network name to 192.168.169.99.  
Syntax:  
^BNT  
Set the TakeNote  
network port for  
the specified  
"'^BNT-<vt addr range>,<network port>'"  
Variable:  
variable text address range = 1 - 4000.  
network port = 1 - 65535.  
Example:  
Addresses.  
SEND_COMMAND Panel,"'^BNT-973,5000'"  
Sets the TakeNote button network port to 5000.  
^BOP  
The button opacity can be specified as a decimal between 0 - 255, where zero (0) is  
invisible and 255 is opaque, or as a HEX code, as used in the color commands by  
preceding the HEX code with the # sign. In this case, #00 becomes invisible and #FF  
becomes opaque. If the opacity is set to zero (0), this does not make the button inactive,  
only invisible.  
Set the button  
opacity.  
Syntax:  
"'^BOP-<vt addr range>,<button states range>,<button opacity>'"  
Variable:  
variable text address range = 1 - 4000.  
button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons  
1 = Off state and 2 = On state).  
button opacity = 0 (invisible) - 255 (opaque).  
Example:  
SEND_COMMAND Panel,"'^BOP-500.504&510.515,1,200'"  
Example 2:  
SEND_COMMAND Panel,"'^BOP-500.504&510.515,1,#C8'"  
Both examples set the opacity of the buttons with the variable text range of 500-504 and  
510-515 to 200.  
113  
5" Modero Widescreen Touch Panel  
Programming  
"^" Button Commands (Cont.)  
^BOR  
information.  
Set a border to a  
specific border  
style associated  
with a border  
value for those  
buttons with a  
defined address  
range.  
Syntax:  
"'^BOR-<vt addr range>,<border style name or border value>'"  
Variable:  
variable text address range = 1 - 4000.  
border value = 0 - 41.  
Examples:  
SEND_COMMAND Panel,"'^BOR-500.504&510.515,10'"  
Sets the border by number (#10) to those buttons with the variable text range of 500-504  
& 510-515.  
SEND_COMMAND Panel,"'^BOR-500.504&510,AMX Elite -M'"  
Sets the border by name (AMX Elite) to those buttons with the variable text range of  
500-504 & 510-515.  
The border style is available through the TPDesign4 border-style drop-down list. Refer to  
^BOS  
Syntax:  
Set the button to  
display either a  
Video or  
Non-Video  
window.  
"'^BOS-<vt addr range>,<button states range>,<video state>'"  
Variable:  
variable text address range = 1 - 4000.  
button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons  
1 = Off state and 2 = On state).  
video state = Video Off = 0 and Video On = 1.  
Example:  
SEND_COMMAND Panel,"'^BOS-500,1,1'"  
Sets the button to display video.  
^BPP  
Zero clears the flag.  
Set or clear the  
protected page flip  
flag of a  
Syntax:  
"'^BPP-<vt addr range>,<protected page flip flag value>'"  
Variable:  
button.  
variable text address range = 1 - 4000.  
protected page flip flag value range = 0 - 4 (0 clears the flag).  
Example:  
SEND_COMMAND Panel,"'^BPP-500,1'"  
Sets the button to protected page flip flag 1 (sets it to password 1).  
114  
5" Modero Widescreen Touch Panel  
Programming  
"^" Button Commands (Cont.)  
^BRD  
Only if the specified border is not the same as the current border. The border names are  
available through the TPDesign4 border-name drop-down list.  
Set the border of  
a button state/  
states.  
Syntax:  
"'^BRD-<vt addr range>,<button states range>,<border name>'"  
Variable:  
variable text address range = 1 - 4000.  
button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons  
1 = Off state and 2 = On state).  
Example:  
SEND_COMMAND Panel,"'^BRD-500.504&510.515,1&2,Quad Line'"  
Sets the border by name (Quad Line) to those buttons with the variable text range of  
500-504 & 510-515.  
^BSF  
Note: Select one button at a time (single variable text address). Do not assign a variable  
text address range to set focus to multiple buttons. Only one variable text address can be  
in focus at a time.  
Set the focus to  
the text area.  
Syntax:  
"'^BSF-<vt addr range>,<selection value>'"  
Variable:  
variable text address range = 1 - 4000.  
selection value = Unselect = 0 and select = 1.  
Example:  
SEND_COMMAND Panel,"'^BSF-500,1'"  
Sets the focus to the text area of the button.  
^BSM  
This command causes the text areas to send their text as strings to the NetLinx Master.  
Submit text for  
Syntax:  
text area buttons.  
"'^BSM-<vt addr range>'"  
Variable:  
variable text address range = 1 - 4000.  
Example:  
SEND_COMMAND Panel,"'^BSM-500'"  
Submits the text of the text area button.  
^BSO  
If the sound name is blank the sound is then cleared. If the sound name is not matched,  
the button sound is not changed.  
Set the sound  
played when a  
button is pressed.  
Syntax:  
"'^BSO-<vt addr range>,<button states range>,<sound name>'"  
Variable:  
variable text address range = 1 - 4000.  
button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons  
1 = Off state and 2 = On state).  
sound name = (blank - sound cleared, not matched - button sound not changed).  
Example:  
SEND_COMMAND Panel,"'^BSO-500,1&2,music.wav'"  
Assigns the sound 'music.wav' to the button Off/On states.  
115  
5" Modero Widescreen Touch Panel  
Programming  
"^" Button Commands (Cont.)  
^BVL  
Syntax:  
Log-On/Log-Off  
the computer  
control  
"'^BVL-<vt addr range>,<connection>'"  
Variable:  
variable text address range = 1 - 4000.  
connection = 0 (Log-Off connection) and 1 (Log-On connection).  
Example:  
connection.  
SEND_COMMAND Panel,"'^BVL-500,0'"  
Logs-off the computer control connection of the button.  
Syntax:  
^BVN  
Set the computer  
control remote  
host for the  
SEND_COMMAND <DEV>,"'^BVN-<vt addr range>,<remote host>'"  
Variables:  
variable text address range = 1 - 4000.  
remote host = 1 - 50 ASCII characters.  
Example:  
specified address.  
SEND_COMMAND Panel,"'^BVN-500,191.191.191.191'"  
Sets the remote host to '191.191.191.191' for the specific computer control button.  
Syntax:  
^BVP  
Set the network  
password for the  
specified address.  
"'^BVP-<vt addr range>,<network password>'"  
Variable:  
variable text address range = 1 - 4000.  
network password = 1 - 50 ASCII characters.  
Example:  
SEND_COMMAND Panel,"'^BVP-500,PCLOCK'"  
Sets the password to PCLOCK for the specific PC control button.  
Syntax:  
^BVT  
Set the computer  
control network  
port for the  
"'^BVT-<vt addr range>,<network port>'"  
Variable:  
variable text address range = 1 - 4000.  
network port = 1 - 65535.  
Example:  
specified address.  
SEND_COMMAND Panel,"'^BVT-500,5000'"  
Sets the network port to 5000.  
^BWW  
By default, word-wrap is Off.  
Set the button  
word wrap  
Syntax:  
"'^BWW-<vt addr range>,<button states range>,<word wrap>'"  
feature to those  
buttons with a  
defined address  
range.  
Variable:  
variable text address range = 1 - 4000.  
button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons  
1 = Off state and 2 = On state).  
word wrap = (0=Off and 1=On). Default is Off.  
Example:  
SEND_COMMAND Panel,"'^BWW-500,1,1'"  
Sets the word wrap on for the button’s Off state.  
116  
5" Modero Widescreen Touch Panel  
Programming  
"^" Button Commands (Cont.)  
^CPF  
Syntax:  
Clear all page flips  
from a button.  
"'^CPF-<vt addr range>'"  
Variable:  
variable text address range = 1 - 4000.  
Example:  
SEND_COMMAND Panel,"'^CPF-500'"  
Clears all page flips from the button.  
Syntax:  
^DPF  
Delete page flips  
from button if it  
already exists.  
"'^DFP-<vt addr range>,<actions>,<page name>'"  
Variable:  
variable text address range = 1 - 4000.  
actions =  
Stan[dardPage] - Flip to standard page  
Prev[iousPage] - Flip to previous page  
Show[Popup] - Show Popup page  
Hide[Popup] - Hide Popup page  
Togg[lePopup] - Toggle popup state  
ClearG[roup] - Clear popup page group from all pages  
ClearP[age] - Clear all popup pages from a page with the  
specified page name  
ClearA[ll] - Clear all popup pages from all pages  
page name = 1 - 50 ASCII characters.  
Example:  
SEND COMMAND Panel,"'^DPF-409,Prev'"  
Deletes the assignment of a button from flipping to a previous page.  
Syntax:  
^ENA  
Enable or  
disable buttons  
with a set  
variable text  
range.  
"'^ENA-<vt addr range>,<command value>'"  
Variable:  
variable text address range = 1 - 4000.  
command value = (0= disable, 1= enable)  
Example:  
SEND_COMMAND Panel,"'^ENA-500.504&510.515,0'"  
Disables button pushes on buttons with variable text range 500-504 & 510-515.  
^FON  
Font ID numbers are generated by the TPDesign4 programmers report.  
Set a font to a  
specific Font ID  
value for those  
buttons with a  
defined address  
range.  
Syntax:  
"'^FON-<vt addr range>,<button states range>,<font value>'"  
Variable:  
variable text address range = 1 - 4000.  
button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons  
1 = Off state and 2 = On state).  
font value = Range = 1 - XXX. Refer to theDefault Font Styles and ID Numbers table on  
Example:  
SEND_COMMAND Panel,"'^FON-500.504&510.515,1&2,4'"  
Sets the font size to font ID #4 for the On and Off states of buttons with the variable text  
range of 500-504 & 510-515.  
The Font ID is generated by TPD4 and is located in TPD4 through the Main menu.  
Panel > Generate Programmer's Report >Text Only Format >Readme.txt.  
117  
5" Modero Widescreen Touch Panel  
Programming  
"^" Button Commands (Cont.)  
^GDI  
Syntax:  
Change the  
bargraph drag  
increment.  
"'^GDI-<vt addr range>,<bargraph drag increment>'"  
Variable:  
variable text address range = 1 - 4000.  
bargraph drag increment = The default drag increment is 256.  
Example:  
SEND_COMMAND Panel,"'^GDI-7,128'"  
Sets the bargraph with variable text 7 to a drag increment of 128.  
^GIV  
Parameters 1,2, and 3 will cause a bargraph or slider to be inverted regardless of  
orientation. Their effect will be as described for joysticks.  
Invert the  
joystick axis to  
move the origin to  
another corner.  
Syntax:  
"'^GIV-<vt addr range>,<joystick axis to invert>'"  
Variable:  
variable text address range = 1 - 4000.  
joystick axis to invert = 0 - 3.  
0 = Normal  
0
2
1
3
1 = Invert horizontal axis  
2 = Invert vertical axis  
3 = Invert both axis locations  
For a bargraph 1 = Invert , 0 = Non Invert  
Example:  
SEND_COMMAND Panel,"'^GIV-500,3'"  
Inverts the joystick axis origin to the bottom right corner.  
Syntax:  
^GLH  
Change the  
bargraph upper  
limit.  
"'^GLH-<vt addr range>,<bargraph hi>'"  
Variable:  
variable text address range = 1 - 4000.  
bargraph limit range = 1 - 65535 (bargraph upper limit range).  
Example:  
SEND_COMMAND Panel,"'^GLH-500,1000'"  
Changes the bargraph upper limit to 1000.  
Syntax:  
^GLL  
Change the  
bargraph lower  
limit.  
"'^GLL-<vt addr range>,<bargraph low>'"  
Variable:  
variable text address range = 1 - 4000.  
bargraph limit range = 1 - 65535 (bargraph lower limit range).  
Example:  
SEND_COMMAND Panel,"'^GLL-500,150'"  
Changes the bargraph lower limit to 150.  
118  
5" Modero Widescreen Touch Panel  
   
Programming  
"^" Button Commands (Cont.)  
^GRD  
Syntax:  
Change the  
bargraph  
ramp-down time  
in 1/10th of a  
second.  
"'^GRD-<vt addr range>,<bargraph ramp down time>'"  
Variable:  
variable text address range = 1 - 4000.  
bargraph ramp down time = In 1/10th of a second intervals.  
Example:  
SEND_COMMAND Panel,"'^GRD-500,200'"  
Changes the bargraph ramp down time to 20 seconds.  
Syntax:  
^GRU  
Change the  
bargraph  
ramp-up time in  
1/10th of a  
second.  
"'^GRU-<vt addr range>,<bargraph ramp up time>'"  
Variable:  
variable text address range = 1 - 4000.  
bargraph ramp up time = In 1/10th of a second intervals.  
Example:  
SEND_COMMAND Panel,"'^GRU-500,100'"  
Changes the bargraph ramp up time to 10 seconds.  
^GSC  
A user can also assign the color by Name and R,G,B value (RRGGBB or RRGGBBAA).  
Change the  
Syntax:  
bargraph slider  
color or joystick  
cursor color.  
"'^GSC-<vt addr range>,<color value>'"  
Variable:  
variable text address range = 1 - 4000.  
Example:  
SEND_COMMAND Panel,"'^GSC-500,12'"  
Changes the bargraph or joystick slider color to Yellow.  
^GSN  
Slider names and cursor names can be found in the TPDesign4 slider name and cursor  
drop-down list.  
Change the  
bargraph slider  
name or joystick  
cursor name.  
Syntax:  
"'^GSN-<vt addr range>,<bargraph slider name>'"  
Variable:  
variable text address range = 1 - 4000.  
bargraph slider name = See table below.  
Bargraph Slider Names:  
None  
Circle -L  
Ball  
Precision  
Circle -S  
Circle -M  
Rectangle -L  
Windows  
Rectangle -S  
Rectangle -M  
Windows Active  
Joystick Cursor Names:  
None  
Circle  
Hand  
Target  
Ball  
Arrow  
Crosshairs  
Gunsight  
Spiral  
Metal  
View Finder  
Example:  
SEND_COMMAND Panel,"'^GSN-500,Ball'"  
Changes the bargraph slider name or the Joystick cursor name to ’Ball’.  
119  
5" Modero Widescreen Touch Panel  
Programming  
"^" Button Commands (Cont.)  
^ICO  
Syntax:  
Set the icon to a  
button.  
"'^ICO-<vt addr range>,<button states range>,<icon index>'"  
Variable:  
variable text address range = 1 - 4000.  
button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons  
1 = Off state and 2 = On state).  
icon index range = 0 - 9900 (a value of 0 is clear).  
Example:  
SEND_COMMAND Panel,"'^ICO-500.504&510.515,1&2,1'"  
Sets the icon for On and Off states for buttons with variable text ranges of 500-504 &  
510-515.  
^JSB  
The alignment of 0 is followed by ',<left>,<top>'. The left and top coordinates are relative  
to the upper left corner of the button.  
Set bitmap/  
picture alignment Syntax:  
using a numeric  
"'^JSB-<vt addr range>,<button states range>,<new text  
alignment>'"  
keypad layout for  
those buttons with  
a defined address  
range.  
Variable:  
variable text address range = 1 - 4000.  
button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons  
1 = Off state and 2 = On state).  
new text alignment = Value of 1 - 9 corresponds to the following locations:  
0
1
4
7
3
6
9
2
5
8
Zero can be used for an absolute position  
Example:  
SEND_COMMAND Panel,"'^JSB-500.504&510.515,1&2,1'"  
Sets the off/on state picture alignment to upper left corner for those buttons with variable  
text ranges of 500-504 & 510-515.  
^JSI  
The alignment of 0 is followed by ',<left>,<top>'. The left and top coordinates are relative  
to the upper left corner of the button.  
Set icon  
alignment using a Syntax:  
numeric keypad  
"'^JSI-<vt addr range>,<button states range>,<new icon  
alignment>'"  
layout for those  
buttons with a  
defined address  
range.  
Variable:  
variable text address range = 1 - 4000.  
button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons  
1 = Off state and 2 = On state).  
new icon alignment = Value of 1 - 9 corresponds to the following locations:  
0
1
4
7
3
6
9
2
5
8
Zero can be used for an absolute position  
Example:  
SEND_COMMAND Panel,"'^JSI-500.504&510.515,1&2,1'"  
Sets the Off/On state icon alignment to upper left corner for those buttons with variable  
text range of 500-504 & 510-515.  
120  
5" Modero Widescreen Touch Panel  
Programming  
"^" Button Commands (Cont.)  
^JST  
The alignment of 0 is followed by ',<left>,<top>'. The left and top coordinates are relative  
to the upper left corner of the button.  
Set text  
alignment using a Syntax:  
numeric keypad  
"'^JST-<vt addr range>,<button states range>,<new text  
alignment>'"  
layout for those  
buttons with a  
defined address  
range.  
Variable:  
variable text address range = 1 - 4000.  
button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons  
1 = Off state and 2 = On state).  
new text alignment = Value of 1 - 9 corresponds to the following locations:  
0
1
4
7
3
6
9
2
5
8
Zero can be used for an absolute position  
Example:  
SEND_COMMAND Panel,"'^JST-500.504&510.515,1&2,1'"  
Sets the text alignment to the upper left corner for those buttons with variable text ranges  
of 500-504 & 510-515.  
^MBT  
Syntax:  
Set the Mouse  
"'^MBT-<pass data>'"  
Button mode On  
for the virtual PC.  
Variable:  
pass data:  
0 = None  
1 = Left  
2 = Right  
3 = Middle  
Example:  
SEND COMMAND Panel,"'^MBT-1'"  
Sets the mouse button mode to ’Left Mouse Click’.  
^MDC  
Syntax:  
Turn On the  
’Mouse  
double-click’  
feature for the  
virtual PC.  
"'^MDC'"  
Example:  
SEND COMMAND Panel,"'^MDC'"  
Sets the mouse double-click for use with the virtual PC.  
Syntax:  
^SHO  
Show or hide a  
button with a set  
variable text  
range.  
"'^SHO-<vt addr range>,<command value>'"  
Variable:  
variable text address range = 1 - 4000.  
command value = (0= hide, 1= show).  
Example:  
SEND_COMMAND Panel,"'^SHO-500.504&510.515,0'"  
Hides buttons with variable text address range 500-504 & 510-515.  
121  
5" Modero Widescreen Touch Panel  
Programming  
"^" Button Commands (Cont.)  
^TEC  
The Text Effect is specified by name and can be found in TPD4. You can also assign the  
color by name or RGB value (RRGGBB or RRGGBBAA).  
Set the text effect  
color for the  
specified  
Syntax:  
"'^TEC-<vt addr range>,<button states range>,<color value>'"  
addresses/states  
to the specified  
color.  
Variable:  
variable text address range = 1 - 4000.  
button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons  
1 = Off state and 2 = On state).  
Example:  
SEND_COMMAND Panel,"'^TEC-500.504&510.515,1&2,12'"  
Sets the text effect color to Very Light Yellow on buttons with variable text 500-504  
and 510-515.  
^TEF  
The Text Effect is specified by name and can be found in TPD4.  
Set the text effect. Syntax:  
"'^TEF-<vt addr range>,<button states range>,<text effect name>'"  
Variable:  
variable text address range = 1 - 4000.  
button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons  
1 = Off state and 2 = On state).  
text effect name = Refer to theText Effects table on page 124 for a listing of text  
effect names.  
Example:  
SEND_COMMAND Panel,"'^TEF-500.504&510.515,1&2,Soft Drop Shadow  
3'"  
Sets the text effect to Soft Drop Shadow 3 for the button with variable text range 500-504  
and 510-515.  
^TXT  
Sets Non-Unicode text.  
Assign a text  
string to those  
buttons with a  
defined address  
range.  
Syntax:  
"'^TXT-<vt addr range>,<button states range>,<new text>'"  
Variable:  
variable text address range = 1 - 4000.  
button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons  
1 = Off state and 2 = On state).  
new text = 1 - 50 ASCII characters.  
Example:  
SEND_COMMAND Panel,"'^TXT-500.504&510.515,1&2,Test Only'"  
Sets the On and Off state text for buttons with the variable text ranges of  
500-504 & 510-515.  
122  
5" Modero Widescreen Touch Panel  
 
Programming  
"^" Button Commands (Cont.)  
^UNI  
For the ^UNI command (%UN and ^BMF command), the Unicode text is sent as  
ASCII-HEX nibbles.  
Set Unicode text.  
Syntax:  
"'^UNI-<vt addr range>,<button states range>,<unicode text>'"  
Variable:  
variable text address range = 1 - 4000.  
button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons  
1 = Off state and 2 = On state).  
unicode text = Unicode HEX value.  
Example:  
SEND_COMMAND Panel,"'^UNI-500,1,0041'"  
Sets the button’s unicode character to ’A’.  
Note: To send the variable text ’A’ in unicode to all states of the variable text  
button 1, (for which the character code is 0041 Hex), send the following command:  
SEND_COMMAND TP,"'^UNI-1,0,0041'"  
Note: Unicode is always represented in a HEX value. TPD4 generates (through the Text  
Enter Box dialog) unicode HEX values. Refer to the TPDesign4 Instruction Manual for  
more information.  
123  
5" Modero Widescreen Touch Panel  
 
Programming  
Text Effect Names  
The following is a listing of text effects names. This list is associated with the ^TEF command on  
Text Effects  
• Glow -S  
• Hard Drop Shadow 6  
• Glow -M  
• Hard Drop Shadow 7  
• Glow -L  
• Hard Drop Shadow 8  
• Glow -X  
• Soft Drop Shadow 1 with outline  
• Soft Drop Shadow 2 with outline  
• Soft Drop Shadow 3 with outline  
• Soft Drop Shadow 4 with outline  
• Soft Drop Shadow 5 with outline  
• Soft Drop Shadow 6 with outline  
• Soft Drop Shadow 7 with outline  
• Soft Drop Shadow 8 with outline  
• Medium Drop Shadow 1 with outline  
• Medium Drop Shadow 2 with outline  
• Medium Drop Shadow 3 with outline  
• Medium Drop Shadow 4 with outline  
• Medium Drop Shadow 5 with outline  
• Medium Drop Shadow 6 with outline  
• Medium Drop Shadow 7 with outline  
• Medium Drop Shadow 8 with outline  
• Hard Drop Shadow 1 with outline  
• Hard Drop Shadow 2 with outline  
• Hard Drop Shadow 3 with outline  
• Hard Drop Shadow 4 with outline  
• Hard Drop Shadow 5 with outline  
• Hard Drop Shadow 6 with outline  
• Hard Drop Shadow 7 with outline  
• Hard Drop Shadow 8 with outline  
• Outline -S  
• Outline -M  
• Outline -L  
• Outline -X  
• Soft Drop Shadow 1  
• Soft Drop Shadow 2  
• Soft Drop Shadow 3  
• Soft Drop Shadow 4  
• Soft Drop Shadow 5  
• Soft Drop Shadow 6  
• Soft Drop Shadow 7  
• Soft Drop Shadow 8  
• Medium Drop Shadow 1  
• Medium Drop Shadow 2  
• Medium Drop Shadow 3  
• Medium Drop Shadow 4  
• Medium Drop Shadow 5  
• Medium Drop Shadow 6  
• Medium Drop Shadow 7  
• Medium Drop Shadow 8  
• Hard Drop Shadow 1  
• Hard Drop Shadow 2  
• Hard Drop Shadow 3  
• Hard Drop Shadow 4  
• Hard Drop Shadow 5  
124  
5" Modero Widescreen Touch Panel  
   
Programming  
Button Query Commands  
Button Query commands reply back with a custom event. There will be one custom event for each  
button/state combination. Each query is assigned a unique custom event type. The following example is  
for debug purposes only:  
NetLinx Example: CUSTOM_EVENT[device, Address, Custom event type]  
DEFINE_EVENT  
CUSTOM_EVENT[TP,529,1001]  
CUSTOM_EVENT[TP,529,1002]  
CUSTOM_EVENT[TP,529,1003]  
CUSTOM_EVENT[TP,529,1004]  
CUSTOM_EVENT[TP,529,1005]  
CUSTOM_EVENT[TP,529,1006]  
CUSTOM_EVENT[TP,529,1007]  
CUSTOM_EVENT[TP,529,1008]  
CUSTOM_EVENT[TP,529,1009]  
CUSTOM_EVENT[TP,529,1010]  
CUSTOM_EVENT[TP,529,1011]  
CUSTOM_EVENT[TP,529,1012]  
CUSTOM_EVENT[TP,529,1013]  
CUSTOM_EVENT[TP,529,1014]  
CUSTOM_EVENT[TP,529,1015]  
// Text  
// Bitmap  
// Icon  
// Text Justification  
// Bitmap Justification  
// Icon Justification  
// Font  
// Text Effect Name  
// Text Effect Color  
// Word Wrap  
// ON state Border Color  
// ON state Fill Color  
// ON state Text Color  
// Border Name  
// Opacity  
{
Send_String 0,"'ButtonGet Id=',ITOA(CUSTOM.ID),' Type=',ITOA(CUSTOM.TYPE)"  
Send_String 0,"'Flag =',ITOA(CUSTOM.FLAG)"  
Send_String 0,"'VALUE1 =',ITOA(CUSTOM.VALUE1)"  
Send_String 0,"'VALUE2 =',ITOA(CUSTOM.VALUE2)"  
Send_String 0,"'VALUE3 =',ITOA(CUSTOM.VALUE3)"  
Send_String 0,"'TEXT  
=',CUSTOM.TEXT"  
Send_String 0,"'TEXT LENGTH =',ITOA(LENGTH_STRING(CUSTOM.TEXT))"  
}
125  
5" Modero Widescreen Touch Panel  
 
Programming  
All custom events have the following 6 fields:  
Custom Event Fields  
Field  
Description  
Uint Flag  
0 means text is a standard string, 1 means Unicode encoded string  
button state number  
slong value1  
slong value2  
slong value3  
string text  
actual length of string (this is not encoded size)  
index of first character (usually 1 or same as optional index  
the text from the button  
text length (string encode)  
button text length  
These fields are populated differently for each query command. The text length (String Encode) field is  
not used in any command.  
Button Query Commands  
?BCB  
Syntax:  
Get the current  
border color.  
"'?BCB-<vt addr range>,<button states range>'"  
Variable:  
variable text address range = 1 - 4000.  
button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons  
1 = Off state and 2 = On state).  
custom event type 1011:  
Flag - zero  
Value1 - Button state number  
Value2 - Actual length of string (should be 9)  
Value3 - Zero  
Text - Hex encoded color value (ex: #000000FF)  
Text length - Color name length (should be 9)  
Example:  
SEND COMMAND Panel,"'?BCB-529,1'"  
Gets the button 'OFF state' border color. information.  
The result sent to the Master would be:  
ButtonGet Id = 529 Type = 1011  
Flag = 0  
VALUE1 = 1  
VALUE2 = 9  
VALUE3 = 0  
TEXT = #222222FF  
TEXT LENGTH = 9  
126  
5" Modero Widescreen Touch Panel  
Programming  
Button Query Commands (Cont.)  
?BCF  
Syntax:  
Get the current fill  
color.  
"'?BCF-<vt addr range>,<button states range>'"  
Variable:  
variable text address range = 1 - 4000.  
button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons  
1 = Off state and 2 = On state).  
custom event type 1012:  
Flag - Zero  
Value1 - Button state number  
Value2 - Actual length of string (should be 9)  
Value3 - Zero  
Text - Hex encoded color value (ex: #000000FF)  
Text length - Color name length (should be 9)  
Example:  
SEND COMMAND Panel,"'?BCF-529,1'"  
Gets the button 'OFF state' fill color information.  
The result sent to the Master would be:  
ButtonGet Id = 529 Type = 1012  
Flag = 0  
VALUE1 = 1  
VALUE2 = 9  
VALUE3 = 0  
TEXT = #FF8000FF  
TEXT LENGTH = 9  
?BCT  
Syntax:  
Get the current  
text color.  
"'?BCT-<vt addr range>,<button states range>'"  
Variable:  
variable text address range = 1 - 4000.  
button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons  
1 = Off state and 2 = On state).  
custom event type 1013:  
Flag - Zero  
Value1 - Button state number  
Value2 - Actual length of string (should be 9)  
Value3 - Zero  
Text - Hex encoded color value (ex: #000000FF)  
Text length - Color name length (should be 9)  
Example:  
SEND COMMAND Panel,"'?BCT-529,1'"  
Gets the button 'OFF state' text color information.  
The result sent to Master would be:  
ButtonGet Id = 529 Type = 1013  
Flag = 0  
VALUE1 = 1  
VALUE2 = 9  
VALUE3 = 0  
TEXT = #FFFFFEFF  
TEXT LENGTH = 9  
127  
5" Modero Widescreen Touch Panel  
Programming  
Button Query Commands (Cont.)  
?BMP  
Syntax:  
Get the current  
bitmap name.  
"'?BMP-<vt addr range>,<button states range>'"  
Variable:  
variable text address range = 1 - 4000.  
button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons  
1 = Off state and 2 = On state).  
custom event type 1002:  
Flag - Zero  
Value1 - Button state number  
Value2 - Actual length of string  
Value3 - Zero  
Text - String that represents the bitmap name  
Text length - Bitmap name text length (should be 9)  
Example:  
SEND COMMAND Panel,"'?BMP-529,1'"  
Gets the button 'OFF state' bitmap information.  
The result sent to the Master would be:  
ButtonGet Id = 529 Type = 1002  
Flag = 0  
VALUE1 = 1  
VALUE2 = 9  
VALUE3 = 0  
TEXT = Buggs.png  
TEXT LENGTH = 9  
?BOP  
Syntax:  
Get the overall  
button opacity.  
"'?BOP-<vt addr range>,<button states range>'"  
Variable:  
variable text address range = 1 - 4000.  
button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons  
1 = Off state and 2 = On state).  
custom event type 1015:  
Flag - Zero  
Value1 - Button state number  
Value2 - Opacity  
Value3 - Zero  
Text - Blank  
Text length - Zero  
Example:  
SEND COMMAND Panel,"'?BOP-529,1'"  
Gets the button 'OFF state' opacity information.  
The result sent to the Master would be:  
ButtonGet Id = 529 Type = 1015  
Flag = 0  
VALUE1 = 1  
VALUE2 = 200  
VALUE3 = 0  
TEXT  
=
TEXT LENGTH = 0  
128  
5" Modero Widescreen Touch Panel  
Programming  
Button Query Commands (Cont.)  
?BRD  
Syntax:  
Get the current  
border name.  
"'?BRD-<vt addr range>,<button states range>'"  
Variable:  
variable text address range = 1 - 4000.  
button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons  
1 = Off state and 2 = On state).  
custom event type 1014:  
Flag - Zero  
Value1 - Button state number  
Value2 - Actual length of string  
Value3 - Zero  
Text - String that represents border name  
Text length - Border name length  
Example:  
SEND COMMAND Panel,"'?BRD-529,1'"  
Gets the button 'OFF state' border information.  
The result sent to the Master would be:  
ButtonGet Id = 529 Type = 1014  
Flag = 0  
VALUE1 = 1  
VALUE2 = 22  
VALUE3 = 0  
TEXT = Double Bevel Raised -L  
TEXT LENGTH = 22  
?BWW  
Syntax:  
Get the current  
word wrap flag  
status.  
"'?BWW-<vt addr range>,<button states range>'"  
Variable:  
variable text address range = 1 - 4000.  
button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons  
1 = Off state and 2 = On state).  
custom event type 1010:  
Flag - Zero  
Value1 - Button state number  
Value2 - 0 = no word wrap, 1 = word wrap  
Value3 - Zero  
Text - Blank  
Text length - Zero  
Example:  
SEND COMMAND Panel,"'?BWW-529,1'"  
Gets the button 'OFF state' word wrap flag status information.  
The result sent to the Master would be:  
ButtonGet Id = 529 Type = 1010  
Flag = 0  
VALUE1 = 1  
VALUE2 = 1  
VALUE3 = 0  
TEXT  
=
TEXT LENGTH = 0  
129  
5" Modero Widescreen Touch Panel  
Programming  
Button Query Commands (Cont.)  
?FON  
Syntax:  
Get the current  
font index.  
"'?FON-<vt addr range>,<button states range>'"  
Variable:  
variable text address range = 1 - 4000.  
button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons  
1 = Off state and 2 = On state).  
custom event type 1007:  
Flag - Zero  
Value1 - Button state number  
Value2 - Font index  
Value3 - Zero  
Text - Blank  
Text length - Zero  
Example:  
SEND COMMAND Panel,"'?FON-529,1'"  
Gets the button 'OFF state' font type index information.  
The result sent to the Master would be:  
ButtonGet Id = 529 Type = 1007  
Flag = 0  
VALUE1 = 1  
VALUE2 = 72  
VALUE3 = 0  
TEXT  
TEXT LENGTH = 0  
Syntax:  
=
?ICO  
Get the current  
icon index.  
"'?ICO-<vt addr range>,<button states range>'"  
Variable:  
variable text address range = 1 - 4000.  
button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons  
1 = Off state and 2 = On state).  
custom event type 1003:  
Flag - Zero  
Value1 - Button state number  
Value2 - Icon Index  
Value3 - Zero  
Text - Blank  
Text length - Zero  
Example:  
SEND COMMAND Panel,"'?ICO-529,1&2'"  
Gets the button 'OFF state' icon index information.  
The result sent to the Master would be:  
ButtonGet Id = 529 Type = 1003  
Flag = 0  
VALUE1 = 2  
VALUE2 = 12  
VALUE3 = 0  
TEXT  
=
TEXT LENGTH = 0  
130  
5" Modero Widescreen Touch Panel  
Programming  
Button Query Commands (Cont.)  
?JSB  
Syntax:  
Get the current  
bitmap  
justification.  
"'?JSB-<vt addr range>,<button states range>'"  
Variable:  
variable text address range = 1 - 4000.  
button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons  
1 = Off state and 2 = On state).  
custom event type 1005:  
Flag - Zero  
Value1 - Button state number  
Value2 - 1 - 9 justify  
Value3 - Zero  
Text - Blank  
Text length - Zero  
Example:  
SEND COMMAND Panel,"'?JSB-529,1'"  
Gets the button 'OFF state' bitmap justification information.  
The result sent to the Master would be:  
ButtonGet Id = 529 Type = 1005  
Flag = 0  
VALUE1 = 1  
VALUE2 = 5  
VALUE3 = 0  
TEXT  
TEXT LENGTH = 0  
Syntax:  
=
?JSI  
Get the current  
icon  
justification.  
"'?JSI-<vt addr range>,<button states range>'"  
Variable:  
variable text address range = 1 - 4000.  
button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons  
1 = Off state and 2 = On state).  
custom event type 1006:  
Flag - Zero  
Value1 - Button state number  
Value2 - 1 - 9 justify  
Value3 - Zero  
Text - Blank  
Text length - Zero  
Example:  
SEND COMMAND Panel,"'?JSI-529,1'"  
Gets the button 'OFF state' icon justification information.  
The result sent to the Master would be:  
ButtonGet Id = 529 Type = 1006  
Flag = 0  
VALUE1 = 1  
VALUE2 = 6  
VALUE3 = 0  
TEXT  
=
TEXT LENGTH = 0  
131  
5" Modero Widescreen Touch Panel  
Programming  
Button Query Commands (Cont.)  
?JST  
Syntax:  
Get the current  
text justification.  
"'?JST-<vt addr range>,<button states range>'"  
Variable:  
variable text address range = 1 - 4000.  
button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons  
1 = Off state and 2 = On state).  
custom event type 1004:  
Flag - Zero  
Value1 - Button state number  
Value2 - 1 - 9 justify  
Value3 - Zero  
Text - Blank  
Text length - Zero  
Example:  
SEND COMMAND Panel,"'?JST-529,1'"  
Gets the button 'OFF state' text justification information.  
The result sent to the Master would be:  
ButtonGet Id = 529 Type = 1004  
Flag = 0  
VALUE1 = 1  
VALUE2 = 1  
VALUE3 = 0  
TEXT  
TEXT LENGTH = 0  
Syntax:  
=
?TEC  
Get the current  
text effect color.  
"'?TEC-<vt addr range>,<button states range>'"  
Variable:  
variable text address range = 1 - 4000.  
button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons  
1 = Off state and 2 = On state).  
custom event type 1009:  
Flag - Zero  
Value1 - Button state number  
Value2 - Actual length of string (should be 9)  
Value3 - Zero  
Text - Hex encoded color value (ex: #000000FF)  
Text length - Color name length (should be 9)  
Example:  
SEND COMMAND Panel,"'?TEC-529,1'"  
Gets the button 'OFF state' text effect color information.  
The result sent to the Master would be:  
ButtonGet Id = 529 Type = 1009  
Flag = 0  
VALUE1 = 1  
VALUE2 = 9  
VALUE3 = 0  
TEXT = #5088F2AE  
TEXT LENGTH = 9  
132  
5" Modero Widescreen Touch Panel  
Programming  
Button Query Commands (Cont.)  
?TEF  
Syntax:  
Get the current  
text effect name.  
"'?TEF-<vt addr range>,<button states range>'"  
Variable:  
variable text address range = 1 - 4000.  
button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons  
1 = Off state and 2 = On state).  
custom event type 1008:  
Flag - Zero  
Value1 - Button state number  
Value2 - Actual length of string  
Value3 - Zero  
Text - String that represents the text effect name  
Text length - Text effect name length  
Example:  
SEND COMMAND Panel,"'?TEF-529,1'"  
Gets the button 'OFF state' text effect name information.  
The result sent to the Master would be:  
ButtonGet Id = 529 Type = 1008  
Flag = 0  
VALUE1 = 1  
VALUE2 = 18  
VALUE3 = 0  
TEXT = Hard Drop Shadow 3  
TEXT LENGTH = 18  
?TXT  
Syntax:  
Get the current  
text information.  
"'?TXT-<vt addr range>,<button states range>,<optional index>'"  
Variable:  
variable text address range = 1 - 4000.  
button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons  
1 = Off state and 2 = On state).  
optional index = This is used if a string was too long to get back in one command.  
The reply will start at this index.  
custom event type 1001:  
Flag - Zero  
Value1 - Button state number  
Value2 - Actual length of string  
Value3 - Index  
Text - Text from the button  
Text length - Button text length  
Example:  
SEND COMMAND Panel,"'?TXT-529,1'"  
Gets the button 'OFF state' text information.  
The result sent to the Master would be:  
ButtonGet Id = 529 Type = 1001  
Flag = 0  
VALUE1 = 1  
VALUE2 = 14  
VALUE3 = 1  
TEXT = This is a test  
TEXT LENGTH = 14  
133  
5" Modero Widescreen Touch Panel  
Programming  
Panel Runtime Operations  
Serial Commands are used in the AxcessX Terminal Emulator mode. These commands are case  
insensitive.  
Panel Runtime Operation Commands  
ABEEP  
Syntax:  
Output a single  
beep even if beep  
is Off.  
"'ABEEP'"  
Example:  
SEND COMMAND Panel,"'ABEEP'"  
Outputs a beep of duration 1 beep even if beep is Off.  
Syntax:  
ADBEEP  
Output a double  
beep even if beep  
is Off.  
"'ADBEEP'"  
Example:  
SEND COMMAND Panel,"'ADBEEP'"  
Outputs a double beep even if beep is Off.  
@AKB  
Keyboard string is set to null on power up and is stored until power is lost. The Prompt  
Text is optional.  
Pop up the  
keyboard icon and Syntax:  
initialize the text  
"'@AKB-<initial text>;<prompt text>'"  
string to that  
specified.  
Variables:  
initial text = 1 - 50 ASCII characters.  
prompt text = 1 - 50 ASCII characters.  
Example:  
SEND COMMAND Panel,"'@AKB-Texas;Enter State'"  
Pops up the Keyboard and initializes the text string 'Texas' with prompt text 'Enter State'.  
Keyboard string is set to null on power up and is stored until power is lost.  
Syntax:  
AKEYB  
Pop up the  
keyboard icon and  
initialize the text  
string to that  
specified.  
"'AKEYB-<initial text>'"  
Variables:  
initial text = 1 - 50 ASCII characters.  
Example:  
SEND COMMAND Panel,"'AKEYB-This is a Test'"  
Pops up the Keyboard and initializes the text string 'This is a Test'.  
The keypad string is set to null on power up and is stored until power is lost.  
Syntax:  
AKEYP  
Pop up the  
keypad icon and  
initialize the text  
string to that  
specified.  
"'AKEYP-<number string>'"  
Variables:  
number string = 0 - 9999.  
Example:  
SEND COMMAND Panel,"'AKEP-12345'"  
Pops up the Keypad and initializes the text string '12345'.  
AKEYR  
Remove keyboard or keypad that was displayed using 'AKEYB', 'AKEYP', 'PKEYP',  
@AKB, @AKP, @PKP, @EKP, or @TKP commands.  
Remove the  
Keyboard/  
Keypad.  
Syntax:  
"'AKEYR'"  
Example:  
SEND COMMAND Panel,"'AKEYR'"  
Removes the Keyboard/Keypad.  
134  
5" Modero Widescreen Touch Panel  
 
Programming  
Panel Runtime Operation Commands (Cont.)  
@AKP  
Keypad string is set to null on power up and is stored until power is lost. The Prompt Text  
is optional.  
Pop up the  
keypad icon and  
initialize the text  
string to that  
specified.  
Syntax:  
"'@AKP-<initial text>;<prompt text>'"  
Variables:  
initial text = 1 - 50 ASCII characters.  
prompt text = 1 - 50 ASCII characters.  
Example:  
SEND COMMAND Panel,"'@AKP-12345678;ENTER PASSWORD'"  
Pops up the Keypad and initializes the text string '12345678' with prompt text ’ENTER  
PASSWORD’.  
@AKR  
Remove keyboard or keypad that was displayed using 'AKEYB', 'AKEYP', 'PKEYP',  
@AKB, @AKP, @PKP, @EKP, or @TKP commands.  
Remove the  
Keyboard/  
Keypad.  
Syntax:  
"'@AKR'"  
Example:  
SEND COMMAND Panel,"'@AKR'"  
Removes the Keyboard/Keypad.  
Syntax:  
BEEP  
Output a beep.  
"'BEEP'"  
Example:  
SEND COMMAND Panel,"'BEEP'"  
Outputs a beep.  
BRIT  
Syntax:  
Set the panel  
brightness.  
"'BRIT-<brightness level>'"  
Variable:  
brightness level = 0 - 100.  
Example:  
SEND COMMAND Panel,"'BRIT-50'"  
Sets the brightness level to 50.  
Syntax:  
@BRT  
Set the panel  
brightness.  
"'@BRT-<brightness level>'"  
Variable:  
brightness level = 0 - 100.  
Example:  
SEND COMMAND Panel,"'@BRT-70'"  
Sets the brightness level to 70.  
Syntax:  
DBEEP  
Output a  
"'DBEEP'"  
double beep.  
Example:  
SEND COMMAND Panel,"'DBEEP'"  
Outputs a double beep.  
135  
5" Modero Widescreen Touch Panel  
Programming  
Panel Runtime Operation Commands (Cont.)  
@EKP  
Pops up the keypad icon and initializes the text string to that specified. The Prompt Text is  
optional.  
Extend the  
Keypad.  
Syntax:  
"'@EKP-<initial text>;<prompt text>'"  
Variables:  
initial text = 1 - 50 ASCII characters.  
prompt text = 1 - 50 ASCII characters.  
Example:  
SEND COMMAND Panel,"'@EKP-33333333;Enter Password'"  
Pops up the Keypad and initializes the text string '33333333' with prompt text 'Enter  
Password'.  
PKEYP  
Pops up the keypad icon and initializes the text string to that specified. Keypad displays a  
'*' instead of the numbers typed. The Prompt Text is optional.  
Present a private  
keypad.  
Syntax:  
"'PKEYP-<initial text>'"  
Variables:  
initial text = 1 - 50 ASCII characters.  
Example:  
SEND COMMAND Panel,"'PKEYP-123456789'"  
Pops up the Keypad and initializes the text string '123456789' in '*'.  
@PKP  
Pops up the keypad icon and initializes the text string to that specified. Keypad displays a  
'*' instead of the numbers typed. The Prompt Text is optional.  
Present a private  
keypad.  
Syntax:  
"'@PKP-<initial text>;<prompt text>'"  
Variables:  
initial text = 1 - 50 ASCII characters.  
prompt text = 1 - 50 ASCII characters.  
Example:  
SEND COMMAND Panel,"'@PKP-1234567;ENTER PASSWORD'"  
Pops up the Keypad and initializes the text string 'ENTER PASSWORD' in '*'.  
SETUP  
Syntax:  
Send panel to  
SETUP page.  
"'SETUP'"  
Example:  
SEND COMMAND Panel,"'SETUP'"  
Sends the panel to the Setup Page.  
Syntax:  
SLEEP  
Force the panel  
into screen saver  
mode.  
"'SLEEP'"  
Example:  
SEND COMMAND Panel,"'SLEEP'"  
Forces the panel into screen saver mode.  
136  
5" Modero Widescreen Touch Panel  
Programming  
Panel Runtime Operation Commands (Cont.)  
@SOU  
Syntax:  
Play a sound file.  
"'@SOU-<sound name>'"  
Variables:  
sound name = Name of the sound file. Supported sound file formats  
are: WAV & MP3.  
Example:  
SEND COMMAND Panel,"'@SOU-Music.wav'"  
Plays the 'Music.wav' file.  
@TKP  
Pops up the keypad icon and initializes the text string to that specified. The Prompt Text is  
optional.  
Present a  
telephone  
keypad.  
Syntax:  
"'@TKP-<initial text>;<prompt text>'"  
Variables:  
initial text = 1 - 50 ASCII characters.  
prompt text = 1 - 50 ASCII characters.  
Example:  
SEND COMMAND Panel,"'@TKP-999.222.1211;Enter Phone Number'"  
Pops-up the Keypad and initializes the text string '999.222.1211' with prompt text 'Enter  
Phone Number'.  
TPAGEON  
This command turns On page tracking, whereby when the page or popups change, a  
string is sent to the Master. This string may be captured with a CREATE_BUFFER  
command for one panel and sent directly to another panel.  
Turn On page  
tracking.  
Syntax:  
"'TPAGEON'"  
Example:  
SEND COMMAND Panel,"'TPAGEON'"  
Turns On page tracking.  
Syntax:  
TPAGEOFF  
Turn Off page  
tracking.  
"'TPAGEOFF'"  
Example:  
SEND COMMAND Panel,"'TPAGEOFF'"  
Turns Off page tracking.  
Syntax:  
@VKB  
Popup the  
virtual  
keyboard.  
"'@VKB'"  
Example:  
SEND COMMAND Panel,"'@VKB'"  
Pops-up the virtual keyboard.  
Syntax:  
WAKE  
Force the panel  
out of screen  
saver mode.  
"'WAKE'"  
Example:  
SEND COMMAND Panel,"'WAKE'"  
Forces the panel out of the screen saver mode.  
137  
5" Modero Widescreen Touch Panel  
Programming  
Input Commands  
These Send Commands are case insensitive.  
Input Commands  
^CAL  
Syntax:  
Put panel in  
"'^CAL'"  
calibration mode.  
Example:  
SEND COMMAND Panel,"'^CAL'"  
Puts the panel in calibration mode.  
Syntax:  
^KPS  
Set the  
"'^KPS-<pass data>'"  
keyboard  
passthru.  
Variable:  
pass data:  
<blank/empty> = Disables the keyboard.  
0 = Pass data to G4 application (default). This can be used with VPC or text areas.  
1 - 4 = Not used.  
5 = Sends out data to the Master.  
Example:  
SEND COMMAND Panel,"'^KPS-5'"  
Sets the keyboard passthru to the Master. Option 5 sends keystrokes directly to the  
Master via the Send Output String mechanism. This process sends a virtual keystroke  
command (^VKS) to the Master.  
Example 2:  
SEND COMMAND Panel,"'^KPS-0'"  
Disables the keyboard passthru to the Master.  
The following point defines how the parameters within this command work:  
• Accepts keystrokes from any of these sources: attached USB keyboard or Virtual  
keyboard.  
^VKS  
Key presses and key releases are not distinguished except in the case of CTRL, ALT, and  
SHIFT.  
Send one or more  
virtual key strokes Refer to theEmbedded Codes table on page 139 that define special characters which  
to the G4  
can be included with the string but may not be represented by the ASCII character set.  
application.  
Syntax:  
"'^VKS-<string>'"  
Variable:  
string = Only 1 string per command/only one stroke per command.  
Example:  
SEND COMMAND Panel,"'^VKS-'8"  
Sends out the keystroke 'backspace' to the G4 application.  
138  
5" Modero Widescreen Touch Panel  
 
Programming  
Embedded codes  
The following is a list of G4 compatible embedded codes:  
Embedded Codes  
Decimal numbers Hexidecimal values  
Virtual keystroke  
8
($08)  
($0D)  
($1B)  
($80)  
($81)  
($82)  
($83)  
($84)  
($85)  
($86)  
($87)  
($88)  
($89)  
($8A)  
($8B)  
($8C)  
($8D)  
($8E)  
($8F)  
($90)  
($91)  
($92)  
($93)  
($94)  
($95)  
($96)  
($97)  
($98)  
($99)  
($9A)  
($9B)  
($9C)  
($9D)  
($9E)  
($9F)  
($A0)  
($A1)  
($A2)  
($C0)  
($C1)  
($C2)  
Backspace  
Enter  
13  
27  
ESC  
128  
129  
130  
131  
132  
133  
134  
135  
136  
137  
138  
139  
140  
141  
142  
143  
144  
145  
146  
147  
148  
149  
150  
151  
152  
153  
154  
155  
156  
157  
158  
159  
160  
161  
162  
192  
193  
194  
CTRL key down  
ALT key down  
Shift key down  
F1  
F2  
F3  
F4  
F5  
F6  
F7  
F8  
F9  
F10  
F11  
F12  
Num Lock  
Caps Lock  
Insert  
Delete  
Home  
End  
Page Up  
Page Down  
Scroll Lock  
Pause  
Break  
Print Screen  
SYSRQ  
Tab  
Windows  
Menu  
Up Arrow  
Down Arrow  
Left Arrow  
Right Arrow  
CTRL key up  
ALT key up  
Shift key up  
139  
5" Modero Widescreen Touch Panel  
   
Programming  
Panel Setup Commands  
These commands are case insensitive.  
Panel Setup Commands  
^MUT  
Syntax:  
Set the panel  
mute state.  
"'^MUT-<mute state>'"  
Variable:  
mute state= 0 = Mute Off and 1 = Mute On.  
Example:  
SEND_COMMAND Panel,"'^MUT-1''"  
Sets the panel’s master volume to mute.  
@PWD sets the level 1 password only.  
Syntax:  
@PWD  
Set the page flip  
password.  
"'@PWD-<page flip password>'"  
Variables:  
page flip password = 1 - 50 ASCII characters.  
Example:  
SEND COMMAND Panel,"'@PWD-Main'"  
Sets the page flip password to 'Main'.  
Password level is required and must be 1 - 4.  
Syntax:  
^PWD  
Set the page flip  
password.  
"'^PWD-<password level>,<page flip password>'"  
Variables:  
password level = 1 - 4.  
page flip password = 1 - 50 ASCII characters.  
Example:  
SEND COMMAND Panel,"'^PWD-1,Main'"  
Sets the page flip password on Password Level 1 to 'Main'.  
@RPP resets the protected password to its default (1988).  
Syntax:  
@RPP  
Reset the  
protected  
password.  
"'@RPP'"  
Example:  
SEND COMMAND Panel,"'@RPP'"  
Resets the protected Setup page password to ‘1988’.  
Syntax:  
^VOL  
Set the panel  
volume.  
"'^VOL-<volume level>'"  
Variable:  
volume level = 0 - 100. 100 is maximum volume setting.  
Example:  
SEND_COMMAND Panel,"'^VOL-50'"  
Set the panel volume to 50.  
140  
5" Modero Widescreen Touch Panel  
 
Programming  
Dynamic Image Commands  
The following is a listing and descriptions of Dynamic Image Commands.  
Dynamic Image Commands  
^BBR  
Syntax:  
Set the bitmap of  
a button to use a  
particular  
"'^BBR-<vt addr range>,<button states range>,<resource name>'"  
Variable:  
variable text address range = 1 - 4000.  
resource.  
button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons  
1 = Off state and 2 = On state).  
resource name = 1 - 50 ASCII characters.  
Example:  
SEND_COMMAND Panel,"'^BBR-700,1,Sports_Image'"  
Sets the resource name of the button to ’Sports_Image’.  
^RAF  
^RFR  
Syntax:  
Force a refresh for  
a given resource.  
"'^RFR-<resource name>'"  
Variable:  
resource name = 1 - 50 ASCII characters.  
Example:  
SEND_COMMAND Panel,"'^RFR-Sports_Image'"  
Forces a refresh on ’Sports_Image’.  
Syntax:  
^RMF  
Modify an  
"'^RMF-<resource name>,<data>'"  
existing resource.  
Variable:  
resource name = 1 - 50 ASCII characters  
data = Refer to the table in the RAF command for more information.  
Example:  
SEND_COMMAND Panel,"'^RMF-Sports_Image,%ALab_Test/  
Images%Ftest.jpg'"  
Changes the resource ’Sports_Image’ file name to ’test.jpg’ and the path to ’Lab_Test/  
Images’.  
^RSR  
Syntax:  
Change the  
"'^RSR-<resource name>,<refresh rate>'"  
refresh rate for a  
given resource.  
Variable:  
resource name = 1 - 50 ASCII characters.  
refresh rate = Measured in seconds.  
Example:  
SEND_COMMAND Panel,"'^RSR-Sports_Image,5'"  
Sets the refresh rate to 5 seconds for the given resource (’Sports_Image’).  
141  
5" Modero Widescreen Touch Panel  
 
Programming  
Dynamic Image Commands (Cont.)  
^RAF  
Adds any and all resource parameters by sending embedded codes and data.  
Add new  
Syntax:  
resources.  
"'^RAF-<resource name>,<data>'"  
Variable:  
resource name = 1 - 50 ASCII characters.  
data = Refers to the embedded codes, see table below.  
Embedded Codes:  
Parameter  
Description  
Embedded Code  
’%P<0-1>’  
Set protocol. HTTP (0) or FTP (1).  
Set Username for authentication.  
protocol  
user  
’%U<user>’  
password  
host  
Set Password for authentication.  
’%S<password>’  
’%H<host>’  
Set Host Name (fully qualified  
DNS or IP Address).  
file  
Full path to the location of the file or  
program that will return the resource.  
The path must be a valid HTTP URL  
minus the protocol and host. The  
only exception to this is the inclusion  
of special escape sequences and in  
the case of the FTP protocol, regular  
expressions.  
’%F<file>’  
path  
Set Directory path. The path must  
be a valid HTTP URL minus the  
protocol, host, and filename. The  
only exception to this is the  
’%A<path>’  
inclusion of special escape  
sequences and in the case of the  
FTP protocol, regular expressions.  
refresh  
The number of seconds between  
refreshes in which the resource is  
downloaded again. Refreshing a  
resource causes the button  
’%R<refresh 1-65535>’  
displaying that resource to refresh  
also. The default value is 0 (only  
download the resource once).  
Set the newest file. A value of 1  
means that only the most recent file  
matching the pattern is downloaded.  
newest  
’%N<0-1>’  
’%V<0-1>’  
Set the value of the preserve flag.  
Default is 0. Currently preserve has  
no function.  
preserve  
Example:  
SEND_COMMAND Panel,"'^RAF-New Image,%P0%HAMX.COM%ALab/  
Test_file%Ftest.jpg'"  
Adds a new resource. The resource name is ’New Image’, %P (protocol) is an HTTP, %H  
(host name) is AMX.COM, %A (file path) is Lab/Test file, and %F (file name) is test.jpg.  
142  
5" Modero Widescreen Touch Panel  
 
Troubleshooting  
Troubleshooting  
This section describes the solutions to possible hardware/firmware issues that could arise during the  
common operation of a Modero touch panel.  
Troubleshooting Information  
Symptom  
Solution  
My USB drivers has a yellow  
exclamation point and doesn’t  
appear to be working.  
The USB driver was incorrectly installed and should be re-installed:  
• Power up the panel without the USB cable connected to the panel.  
• Plug in the USB cable into the G4 panel. You should see a USB icon  
show up in the System Tray.  
• Double click on the icon to bring up the list of USB devices (you  
should see the "AMX USB LAN LINK" device in the list).  
• If the "Install Driver" dialog doesn't appear automatically, select the  
"Properties" button and then the "Update Driver" button.  
• When the Install Driver dialog does appear, click Next to accept all  
the default prompts.  
• The OS will notify you that the driver you are installing/updating does  
not have a digital signature. This is acceptable, agree to continue the  
installation.  
• After installation is complete, the exclamation point should disappear.  
When using G4 WebControl to  
communicate with a target panel, a  
VNC Server dialog appears on my  
screen.  
• During a WebControl connection to a target panel you are prompted  
with a G4 Authentication dialog which asks you to enter the assigned  
password for the panel (before gaining access).  
• If you are ever prompted with a VNC Server dialog, you must enter  
the IP Address of the target panel. This can be found within the  
Setup > Protected Setup > System Connection page.  
- This IP Address of the panel appears within the IP Settings  
section of this page  
• Enter the IP Address and click OK. You will then be prompted with  
the G4 Authentication popup where you must enter the panel’s  
WebControl password.  
While attempting to communicate • A Green communication icon indicates that a connection has been  
directly with the Virtual Master (on  
the PC) via a USB connection, I  
can’t get my communication icon  
to turn Green.  
established to the target Master or target Virtual Master.  
• Launch NetLinx Studio and configure the Master Connection  
communication settings for a Virtual Master.  
• Navigate to the System connection page and toggle the  
Type field to USB.  
• Make sure the Type-A USB connector is securely connected to the  
PC.  
• Make sure the panel DOESN’T have the mini-USB connected and  
TURN OFF the panel.  
• Once the panel has turned ON THEN connect the mini-USB to the  
Program Port. The USB icon should appear in your system tray. If it  
• The panel can take a few minutes to detect the connection to the PC.  
143  
5" Modero Widescreen Touch Panel  
   
Troubleshooting  
Troubleshooting Information (Cont.)  
Symptom  
Solution  
My Modero panel isn’t appearing  
in my Workspace window.  
• Verify that the System number is the same on both the NetLinx  
Workspace window and the System Connection page on the Modero  
panel.  
• Verify you have entered the proper NetLinx Master IP and connection  
methods into the Master Connection section of the System  
Connection page.  
My Modero panel can’t obtain a  
DHCP Address  
In requesting a DHCP Address, the DHCP Server can take up to a few  
minutes to provide the address.  
• Verify there is an active Ethernet connection attached to the rear of  
the Modero before beginning these procedures.  
• Select Diagnostics > Network Address, from the Main menu and  
verify the System number.  
• If the IP Address field is still empty, give the Modero a few minutes to  
negotiate a DHCP Address and try again.  
My panel is not showing up in the If you a Virtual Master has already connected to the target panel, the  
Virtual Master’s System list of  
connected devices.  
G4 device retains the information of the previous Virtual Master System  
number.  
• Reboot the panel without the USB cable plugged into the panel.  
• Configure NetLinx Studio for a Virtual Master connection. Note the  
System Number used in the Edit Settings window.  
• Stop communication on the Virtual Master by going to Settings >  
Stop Communications.  
• Click Yes to stop communication.  
• Select the System Number (from the Online Tree tab) and use a right  
mouse click to select Refresh System. This re-establishes  
communication with the Virtual Master.  
• Plug-in the mini-USB cable into the corresponding port on the panel.  
• Wait a few seconds and refresh the system. This re-establishes  
communication with the Virtual Master. The panel should now appear  
in the list of available devices.  
My Connection Status button isn’t "USB Connecting" is displayed when the panel is trying to establish  
blinking and it says the USB is  
connecting.  
USB communication with the PC (either within the NetLinx Studio or  
TPDesign4 applications).  
• Remove the USB connector from the panel and close any AMX  
applications.  
• Reboot the panel.  
• Launch the AMX application and attempt reconnect to the panel.  
• If using Studio for Virtual Master communication, establish a Virtual  
Master connection, verify the correct System number, stop  
communication with the Virtual Master, and then re-establish  
communication by refreshing the system.  
• After the panel powers-up, reconnect the USB connector to the  
panel.  
• Verify that you have a valid USB connection from within your System  
Tray.  
144  
5" Modero Widescreen Touch Panel  
Troubleshooting  
Troubleshooting Information (Cont.)  
Symptom  
Solution  
My on-screen mouse cursor  
doesn’t appear.  
• The USB connections are not detected until after the particular USB  
connection plugged into the corresponding port on the panel and  
power is cycled to the panel.  
Calibration is not working.  
• After the Modero touch panel has been updated with a new firmware  
kit (downloaded to the panel through NetLinx Studio), the calibration  
could need to be reset.  
• Cycling power to the panel should provide a baseline calibration for  
the particular touch panel. Proceed to the Calibration page and reset  
the on-screen calibration.  
Panel doesn’t respond to my  
touches  
• The protective cover acts to press on the entire LCD and makes  
calibration difficult because the user can’t calibrate on specific  
crosshairs when the sheet is pressing on the whole LCD.  
• Verify that the protective laminate coating on the LCD is removed  
before beginning any calibration process.  
There is a crawling, dashed line on • On some units at some resolutions, there are wavy lines across the  
the left border of the graphics.  
entire screen. This has been seen on middle resolutions and is  
referred to as the "Mid Range Fallout" problem.  
• This is due to the graphics controller settings in the firmware.  
• Update to the latest v2.XX.XX firmware.  
• Visit the www.amx.com > Tech Center > Downloadable Files >  
Firmware Files > Modero panels. Then Download the KIT file to  
your computer.  
NetLinx Studio only detects one of Each Master is give a Device Address of 00000.  
my connected Masters.  
• Only one Master can be assigned to a particular System number. If  
you want to work with multiple Masters, open different instances of  
NetLinx Studio and assign each Master its own System value.  
• Example: a site has an NXC-ME260/64 and an NI-4000. In order to  
work with both units. The ME260/64 can be assigned System #1 and  
the NI-4000 can then be assigned System #2 using two open  
sessions of NetLinx Studio 2.  
I can’t seem to connect to a  
NetLinx Master using my  
NetLinx Studio 2.  
• From the Settings > Master Comm Settings > Communication  
Settings > Settings (for TCP/IP), uncheck the "Automatically Ping  
the Master Controller to ensure availability".  
• The pinging is to determine if the Master is available, and to reply  
with a connection failure instantly if it is not. Without using the ping  
feature, you will still attempt to make a connection, but a failure will  
take longer to be recognized. Some firewalls and networks do not  
allow pinging, though, and the ping will then always result in a failure.  
• When connecting to a NetLinx Master controller via TCP/IP, the  
program will first try to ping the controller before attempting a  
connection. Pinging a device is relatively fast and will determine if the  
device is off-line, or if the TCP/IP address that was entered was  
incorrect. If you decide NOT to ping for availability and the controller  
is off-line, or you have an incorrect TCP/IP address, the program will  
try for 30-45 seconds to establish a connection.  
Note: If you are trying to connect to a master controller that is behind a  
firewall, you may have to uncheck this option. Most firewalls will not  
allow ping requests to pass through for security reasons.  
145  
5" Modero Widescreen Touch Panel  
Troubleshooting  
Troubleshooting Information (Cont.)  
Symptom  
Solution  
I have more that one Modero panel Multiple NetLinx Compatible devices (such as Modero panels) can be  
connected to my System Master  
and only one shows up.  
associated for use with a single Master. Each Modero panel comes  
with a defaulted Device Number value of 10001. When using multiple  
panels, it can become very easy to overlook the need to assign  
different Device Number values to each panel.  
• Press and hold the grey Front Setup Access button for 3 seconds to  
open the Setup page.  
• Press the Protected Setup button (located on the lower-left of the  
panel page), enter 1988 into the on-screen Keypad’s password field,  
and press Done when finished.  
• Enter a Device Number value for the panel into the Device Number  
Keypad. The default is 10001 and the range is from 1 - 32000.  
After downloading a panel file or  
firmware to a G4 device, the panel  
behaves strangely.  
Symptoms include:  
• Having to repeat the download.  
• Inability to make further downloads to the panel. May get "directory"  
errors, "graphics hierarchy" errors, etc.… indicating problems with  
the Flash memory.  
• Panel will not boot, or gets stuck on "AMX" splash screen.  
• Other problems also started after downloading to a new panel or a  
panel with a TPD4 file that takes up a considerable amount of the  
available Flash memory.  
Cause:  
• If the G4 device already contains a large enough file, subsequent  
downloads will take up more space than is available and could often  
corrupt the Flash memory. The demo file that typically ships with G4  
panels is one such file.  
Solution:  
• DO NOT download TPD4 files (of large size) over the demo pages, or  
any other large TPD4 file.  
• First download a small blank one page file to the G4 panel using the  
Normal Transfer option to send/download the page. Reboot the  
device, then do your regular file or firmware download.  
146  
5" Modero Widescreen Touch Panel  
Appendix A  
Appendix A  
Text Formatting Codes for Bargraphs/Joysticks  
Text formatting codes for bargraphs provide a mechanism to allow a portion of a bargraphs text to be  
dynamically provided information about the current status of the level (multistate and traditional). These  
codes would be entered into the text field along with any other text.  
The following is a code list used for bargraphs:  
Bargraph Text Code Inputs  
Code  
Bargraph  
Multi-State Bargraph  
$P  
Display the current percentage of the  
bargraph (derived from the Adjusted  
Level Value as it falls between the  
Range Values)  
Display the current percentage of the  
bargraph (derived from the Adjusted  
Level Value as it falls between the  
Range Values)  
$V  
$L  
$H  
$S  
$A  
Raw Level Value  
Range Low Value  
Range High Value  
N/A  
Raw Level Value  
Range Low Value  
Range High Value  
Current State  
Adjusted Level Value (Range Low Value Adjusted Level Value (Range Low Value  
subtracted from the Raw Level Value)  
subtracted from the Raw Level Value)  
$R  
$$  
Low Range subtracted from the High  
Range  
Low Range subtracted from the High  
Range  
Dollar sign  
Dollar sign  
Buy changing the text on a button (via a VT command) you can modify the codes on a button. When one  
of the Text Formatting Codes is encountered by the firmware it is replaced with the correct value. These  
values are derived from the following operations:  
Formatting Code Operations  
Code  
$P  
Operation  
(Current Value - Range Low Value / Range High Value - Range Low Value) x 100  
Current Level Value  
$V  
$L  
Range Low Value  
$H  
Range High Value  
$S  
Current State (if regular bargraph then resolves to nothing)  
Current Value - Range Low Value  
Range High Value - Range Low Value  
$A  
$R  
Given a current raw level value of 532, a range low value of 500 and a high range value of 600 the  
following text formatting codes would yield the following strings as shown in the table below:  
Example  
Format  
Display  
$P%  
32%  
$A out of $R  
$A of 0 - $R  
$V of $L - $H  
32 out of 100  
32 of 0 - 100  
532 of 500 - 600  
147  
5" Modero Widescreen Touch Panel  
   
Appendix A  
Text Area Input Masking  
Text Area Input Masking can be used to limit the allowed/correct characters that are entered into a text  
area. For example, in working with a zip code, a user could limit the entry to a max length of only 5  
characters but, with input masking, you could limit them to 5 mandatory numerical digits and 4 optional  
numerical digits. A possible use for this feature is to enter information into form fields. The purpose of  
this feature is to:  
• Force you to use correct type of characters (i.e. numbers vs. characters)  
• Limit the number of characters in a text area  
• Suggest proper format with fixed characters  
• Right to Left  
• Required or Optional  
• Change/Force a Case  
• Create multiple logical fields  
• Specify range of characters/number for each field  
With this feature, it is NOT necessary to:  
• Limit you to a choice of selections  
• Handle complex input tasks such as names, days of the weeks or months by name  
• Perform complex validation such as Subnet Mask validation  
Input mask character types  
These character types define what information is allowed to be entered in any specific instance. The  
following table lists what characters in an input mask will define what characters are allowed in any  
given position.  
Character Types  
Character Masking Rule  
0
9
#
L
?
A
a
&
C
Digit (0 to 9, entry required, plus [+] and minus [-] signs not allowed)  
Digit or space (entry not required, plus and minus signs not allowed)  
Digit or space (entry not required; plus and minus signs allowed)  
Letter (A to Z, entry required)  
Letter (A to Z, entry optional)  
Letter or digit (entry required)  
Letter or digit (entry optional)  
Any character or a space (entry required)  
Any character or a space (entry optional)  
The number of the above characters used determines the length of the input masking  
box. Example: 0000 requires an entry, requires digits to be used, and allows only 4  
characters to be entered/used.  
148  
5" Modero Widescreen Touch Panel  
     
Appendix A  
Refer to the following Send Commands for more detailed information:  
^BIM- Sets the input mask for the specified addresses. (see the ^BIM section on  
^BMFsubcommand %MK - sets the input mask of a text area (see the  
Input mask ranges  
These ranges allow a user to specify the minimum and maximum numeric value for a field.  
Only one range is allowed per field. Using a range implies a numeric entry ONLY.  
Input Mask Ranges  
Character Meaning  
[
]
|
Start range  
End range  
Range Separator  
An example from the above table:  
[0|255] This allows a user to enter a value from 0 to 255.  
Input mask next field characters  
These characters allow you to specify a list of characters that cause the keyboard to move the focus to the  
next field when pressed instead of inserting the text into the text area.  
Input Mask Next Field Char  
Character Meaning  
{
}
Start Next Field List  
End Next Field List  
An example from the above table:  
{.} or {:} or {.:} Tells the system that after a user hits any of these keys, proceed to the  
next text area input box.  
Input mask operations  
Input Mask Operators change the behavior of the field in the following way:  
Input Mask Operators  
Character Meaning  
<
>
^
Forces all characters to be converted to lowercase  
Forces all characters to be converted to uppercase  
Sets the overflow flag for this field  
Input mask literals  
To define a literal character, enter any character, other than those shown in the above table (including  
spaces, and symbols). A back-slash ('\') causes the character that follows it to be displayed as the literal  
character. For example, \A is displayed just as the letter A. To define one of the following characters as a  
literal character, precede that character with a back-slash. Text entry operation using Input Masks.  
149  
5" Modero Widescreen Touch Panel  
       
Appendix A  
A keyboard entry using normal text entry is straightforward. However, once an input mask is applied, the  
behavior of the keyboard needs to change to accommodate the input mask's requirement. When working  
with masks, any literal characters in the mask will be "skipped" by any cursor movement including  
cursor keys, backspace, and delete.  
When operating with a mask, the mask should be displayed with placeholders. The "-" character should  
display where you should enter a character. The arrow keys will move between the "-" characters and  
allow you to replace them. The text entry code operates as if it is in the overwrite mode. If the cursor is  
positioned on a character already entered and you type in a new (and valid) character, the new character  
replace the old character. There is no shifting of characters.  
When working with ranges specified by the [] mask, the keyboard allows you to enter a number between  
the values listed in the ranges. If a user enters a value that is larger than the max, the maximum number  
of right-most characters is used to create a new, acceptable value.  
Example 1: If you type "125" into a field accepting 0-100, then the values displayed will be  
"1", "12", "25".  
Example2: If the max for the filed was 20, then the values displayed will  
be "1", "12", "5".  
When data overflows from a numerical field, the overflow value is added to the previous field on the  
chain, if the overflow character was specified. In the above example, if the overflow flag was set, the first  
example will place the "1" into the previous logical field and the second example will place "12" in the  
previous logical field. If the overflow filed already contains a value, the new value will be inserted to the  
right of the current characters and the overflow field will be evaluated. Overflow continues to work until  
a filed with no overflow value is set or there are no more fields left (i.e. reached first field).  
If a character is typed and that characters appear in the Next Field list, the keyboard should move the  
focus to the next field. For example, when entering time, a ":" is used as a next field character. If you hit  
"1:2", the 1 is entered in the current field (hours) and then the focus is moved to the next field and 2 is  
entered in that field.  
When entering time in a 12-hour format, entry of AM and PM is required. Instead of adding  
AM/PM to the input mask specification, the AM/PM should be handled within the NetLinx code. This  
allows a programmer to show/hide and provide discrete feedback for AM and PM.  
Input mask output examples  
The following are some common input masking examples:  
Output Examples  
Common Name  
IP Address Quad  
Hour  
Input Mask  
[0|255]{.}  
Input  
Any value from 0 to 255  
Any value from 1 to 12  
Any value from 0 to 59  
Any value from 0 to 29  
(555) 555-5555  
[1|12]{:}  
Minute/Second  
Frames  
[0|59]{:}  
[0|29]{:}  
Phone Numbers  
Zip Code  
(999) 000-0000  
00000-9999  
75082-4567  
150  
5" Modero Widescreen Touch Panel  
 
Appendix A  
URL Resources  
A URL can be broken into several parts. For example: the URL http://www.amx.com/company-info-  
home.asp. This URL indicates that the protocol in use is http (HyperText Transport Protocol) and that  
the information resides on a host machine named www.amx.com. The image on that host machine is  
given an assignment (by the program) name of company-info-home.asp (Active Server Page).  
The exact meaning of this name on the host machine is both protocol dependent and host dependent. The  
information normally resides in a file, but it could be generated dynamically. This component of the  
URL is called the file component, even though the information is not necessarily in a file.  
A URL can optionally specify a port, which is the port number to which the TCP connection is made on  
the remote host machine. If the port is not specified, the default port for the protocol is used instead. For  
example, the default port for http is 80. An alternative port could be specified as: http://  
www.amx.com:8080/company-info-home.asp.  
Any legal HTTP syntax can be used.  
Special escape sequences  
The system has only a limited knowledge of URL formats in that it transparently passes the URL  
information onto the server for translation. A user can then pass any parameters to the server side  
programs such as CGI scripts or active server pages. However; the system will parse the URL looking  
for special escape codes. When it finds an escape code it replaces that code with a particular piece of  
panel, button, or state information.  
For example, "http://www.amx.com/img.asp?device=$DV" would become "http://www.amx.com/  
img.asp?device=10001". Other used escape sequences include:  
Escape Sequences  
Sequence  
$DV  
$SY  
$IP  
Panel Information  
Device Number  
System Number  
IP Address  
$HN  
$MC  
$ID  
Host Name  
Mac Address  
Neuron ID  
$PX  
$PY  
$BX  
$BY  
$BN  
$ST  
X Resolution of current panel mode/file  
Y Resolution of current panel mode/file  
X Resolution of current button  
Y Resolution of current button  
Name of button  
Current state  
$AC  
$AP  
$CC  
$CP  
$LC  
Address Code  
Address Port  
Channel Code  
Channel Port  
Level Code  
$LP  
Level Port  
151  
5" Modero Widescreen Touch Panel  
   
Appendix A  
152  
5" Modero Widescreen Touch Panel  
Appendix A  
153  
5" Modero Widescreen Touch Panel  
Appendix A  
154  
5" Modero Widescreen Touch Panel  
Appendix A  
155  
5" Modero Widescreen Touch Panels  
It’s Your World - Take Control™  
3000 RESEARCH DRIVE, RICHARDSON, TX 75082 USA • 800.222.0193 • 469.624.8000 • 469-624-7153 fax • 800.932.6993 technical support • www.amx.com  

Hotpoint Cooktop CH60GCIK User Manual
GE 27831 Series User Manual
Frigidaire 790 42741402 User Manual
Fisher Paykel Cooktop CG604D User Manual
Electrolux EHP 600 K User Manual
Eizo Nanao Computer Monitor CE210W User Manual
Diamond Multimedia Radeon X1950PRO512AGP User Manual
Curtis TV1410 User Manual
Asus Computer Monitor VE258Q User Manual
AOC Computer Monitor e941Sw User Manual