Seagate SAVVIO 15K2 SAS ST973252SS User Manual

Product Manual  
®
Savvio 15K.2 SAS  
Standard Models  
Self-Encrypting Drive Models  
ST9146852SS  
ST973452SS  
ST9146752SS  
ST973352SS  
SED FIPS 140-2 Models  
ST9146652SS  
ST973252SS  
100516230  
Rev. E  
March 2011  
Contents  
7.4.1  
Savvio 15K.2 SAS Product Manual, Rev. E  
i
12.5  
ii  
Savvio 15K.2 SAS Product Manual, Rev. E  
iv  
Savvio 15K.2 SAS Product Manual, Rev. E  
List of Figures  
Savvio 15K.2 SAS Product Manual, Rev. E  
1
1.0  
Seagate Technology support services  
SEAGATE ONLINE SUPPORT and SERVICES  
Available services include:  
Presales & Technical support  
Global Support Services telephone numbers & business hours  
Authorized Service Centers  
For information regarding Warranty Support, visit  
http://www.seagate.com/www/en-us/support/warranty_&_returns_assistance  
Savvio 15K.2 SAS Product Manual, Rev. E  
1
   
2.0  
Scope  
This manual describes Seagate Technology® LLC, Savvio® 15K.2 SAS (Serial Attached SCSI) disc drives.  
Savvio drives support the SAS Protocol specifications to the extent described in this manual. The SAS Inter-  
face Manual (part number 100293071) describes the general SAS characteristics of this and other Seagate  
SAS drives. The Self-Encrypting Drive Reference Manual, part number 100515636, describes the interface,  
general operation, and security features available on Self-Encrypting Drive models.  
Note. Previous generations of Seagate Self-Encrypting Drive models were called Full Disk Encryption  
(FDE) models before a differentiation between drive-based encryption and other forms of encryp-  
tion was necessary.  
Product data communicated in this manual is specific only to the model numbers listed in this manual. The data  
listed in this manual may not be predictive of future generation specifications or requirements. If you are  
designing a system which will use one of the models listed or future generation products and need further  
assistance, please contact your Field Applications Engineer (FAE) or our global support services group as  
Unless otherwise stated, the information in this manual applies to standard and Self-Encrypting Drive models.  
Model Number  
ST9146852SS  
ST9146752SS  
ST9146652SS  
ST973452SS  
ST973352SS  
ST973252SS  
Self-Encrypting Drive (SED)  
FIPS 140-2 Level 2 certified  
No  
No  
No  
Yes  
No  
No  
Yes  
Yes  
Yes  
No  
Yes  
Yes  
For more information on FIPS 140-2 Level 2 certification see Section 8.0 on page 35.  
2
Savvio 15K.2 SAS Product Manual, Rev. E  
   
3.0  
Applicable standards and reference documentation  
The drives documented in this manual have been developed as system peripherals to the highest standards of  
design and construction. The drives depends on host equipment to provide adequate power and environment  
for optimum performance and compliance with applicable industry and governmental regulations. Special  
attention must be given in the areas of safety, power distribution, shielding, audible noise control, and temper-  
ature regulation. In particular, the drive must be securely mounted to guarantee the specified performance  
characteristics. Mounting by bottom holes must meet the requirements of Section 11.3  
3.1  
Standards  
The Savvio family complies with Seagate standards as noted in the appropriate sections of this manual and the  
Seagate SAS Interface Manual, part number 100293071.  
The drives are recognized in accordance with UL 60950-1 as tested by UL, CSA 60950-1 as tested by CSA,  
and EN60950-1 as tested by TUV.  
The security features of Self-Encrypting Drive models are based on the “TCG Storage Architecture Core Speci-  
fication” and the “TCG Storage Workgroup Security Subsystem Class: Enterprise_A” specification with addi-  
tional vendor-unique features as noted in this product manual.  
3.1.1  
Electromagnetic compatibility  
The drive, as delivered, is designed for system integration and installation into a suitable enclosure prior to  
use. The drive is supplied as a subassembly and is not subject to Subpart B of Part 15 of the FCC Rules and  
Regulations nor the Radio Interference Regulations of the Canadian Department of Communications.  
The design characteristics of the drive serve to minimize radiation when installed in an enclosure that provides  
reasonable shielding. The drive is capable of meeting the Class B limits of the FCC Rules and Regulations of  
the Canadian Department of Communications when properly packaged; however, it is the user’s responsibility  
to assure that the drive meets the appropriate EMI requirements in their system. Shielded I/O cables may be  
required if the enclosure does not provide adequate shielding. If the I/O cables are external to the enclosure,  
shielded cables should be used, with the shields grounded to the enclosure and to the host controller.  
3.1.1.1  
Electromagnetic susceptibility  
As a component assembly, the drive is not required to meet any susceptibility performance requirements. It is  
the responsibility of those integrating the drive within their systems to perform those tests required and design  
their system to ensure that equipment operating in the same system as the drive or external to the system  
does not adversely affect the performance of the drive. See Tables 2 and 3, DC power requirements.  
Savvio 15K.2 SAS Product Manual, Rev. E  
3
                                 
3.1.2  
Electromagnetic compliance  
Seagate uses an independent laboratory to confirm compliance with the directives/standards for CE Marking  
and C-Tick Marking. The drive was tested in a representative system for typical applications. The selected sys-  
tem represents the most popular characteristics for test platforms. The system configurations include:  
• Typical current use microprocessor  
• Keyboard  
• Monitor/display  
• Printer  
• External modem  
• Mouse  
Although the test system with this Seagate model complies with the directives/standards, we cannot guarantee  
that all systems will comply. The computer manufacturer or system integrator shall confirm EMC compliance  
and provide the appropriate marking for their product.  
Electromagnetic compliance for the European Union  
If this model has the CE Marking it complies with the European Union requirements of the Electromagnetic  
Compatibility Directive 2004/108/EC as put into place on 20 July 2007.  
Australian C-Tick  
If this model has the C-Tick Marking it complies with the Australia/New Zealand Standard AS/NZ CISPR22 and  
meets the Electromagnetic Compatibility (EMC) Framework requirements of Australia’s Spectrum Manage-  
ment Agency (SMA).  
Korean MIC  
If these drives have the Korean Communications Commission (KCC) logo, they comply with paragraph 1 of  
Article 11 of the Electromagnetic Compatibility control Regulation and meet the Electromagnetic Compatibility  
(EMC) Framework requirements of the Radio Research Laboratory (RRL) Communications Commission,  
Republic of Korea.  
These drives have been tested and comply with the Electromagnetic Interference/Electromagnetic  
Susceptibility (EMI/EMS) for Class B products. Drives are tested in a representative, end-user system by a  
Korean-recognized lab.  
• Family name:  
Savvio  
• Certificate number:  
STX-ST914685SS (B)  
Taiwanese BSMI  
If this model has two Chinese words meaning “EMC certification” followed by an eight digit identification num-  
ber, as a Marking, it complies with Chinese National Standard (CNS) 13438 and meets the Electromagnetic  
Compatibility (EMC) Framework requirements of the Taiwanese Bureau of Standards, Metrology, and Inspec-  
tion (BSMI).  
4
Savvio 15K.2 SAS Product Manual, Rev. E  
           
3.1.3  
European Union Restriction of Hazardous Substances (RoHS)  
The European Union Restriction of Hazardous Substances (RoHS) Directive restricts the presence of chemical  
substances, including Lead (Pb), in electronic products effective July 2006.  
A number of parts and materials in Seagate products are procured from external suppliers. We rely on the rep-  
resentations of our suppliers regarding the presence of RoHS substances in these parts and materials. Our  
supplier contracts require compliance with our chemical substance restrictions, and our suppliers document  
their compliance with our requirements by providing material content declarations for all parts and materials for  
the disk drives documented in this publication. Current supplier declarations include disclosure of the inclusion  
of any RoHS-regulated substance in such parts or materials.  
Seagate also has internal systems in place to ensure ongoing compliance with the RoHS Directive and all laws  
and regulations which restrict chemical content in electronic products. These systems include standard operat-  
ing procedures that ensure that restricted substances are not utilized in our manufacturing operations, labora-  
tory analytical validation testing, and an internal auditing process to ensure that all standard operating  
procedures are complied with.  
3.2  
Reference documents  
SCSI Commands Reference Manual  
SAS Interface Manual  
Seagate part number: 100293068  
Seagate part number: 100293071  
ANSI SAS Documents  
SFF-8223  
2.5” Drive Form Factor with Serial Connector  
HSS Backplane Design Guidelines  
SFF-8460  
SFF-8470  
Multi Lane Copper Connector  
SFF-8482  
SAS Plug Connector  
ANSI INCITS.xxx  
ISO/IEC 14776-xxx  
ISO/IEC 14776-xxx  
ISO/IEC 14776-xxx  
Serial Attached SCSI (SAS) Standard (T10/1562-D)  
SCSI Architecture Model-3 (SAM-3) Standard (T10/1561-D)  
SCSI Primary Commands-3 Standard (T10/1416-D)  
SCSI Block Commands-2 Standard (T10/1417-D)  
ANSI Small Computer System Interface (SCSI) Documents  
X3.270-1996  
(SCSI-3) Architecture Model  
Specification for Acoustic Test Requirement and Procedures  
Seagate part number: 30553-001  
Package Test Specification  
Package Test Specification  
Seagate P/N 30190-001 (under 100 lb.)  
Seagate P/N 30191-001 (over 100 lb.)  
In case of conflict between this document and any referenced document, this document takes precedence.  
Savvio 15K.2 SAS Product Manual, Rev. E  
5
             
4.0  
General description  
Savvio drives provide high performance, high capacity data storage for a variety of systems including engi-  
neering workstations, network servers, mainframes, and supercomputers. The Serial Attached SCSI interface  
is designed to meet next-generation computing demands for performance, scalability, flexibility and high-den-  
sity storage requirements.  
Savvio drives are random access storage devices designed to support the Serial Attached SCSI Protocol as  
described in the ANSI specifications, this document, and the SAS Interface Manual (part number 100293071)  
which describes the general interface characteristics of this drive. Savvio drives are classified as intelligent  
peripherals and provide level 2 conformance (highest level) with the ANSI SCSI-1 standard. The SAS connec-  
tors, cables and electrical interface are compatible with Serial ATA (SATA), giving future users the choice of  
populating their systems with either SAS or SATA hard disc drives. This allows you to continue to leverage your  
existing investment in SCSI while gaining a 6Gb/s serial data transfer rate.  
The Self-Encrypting Drive models indicated on the cover of this product manual have provisions for “Security  
group.org).  
The head and disc assembly (HDA) is sealed at the factory. Air recirculates within the HDA through a non-  
replaceable filter to maintain a contamination-free HDA environment.  
Note. Never disassemble the HDA and do not attempt to service items in the sealed enclosure (heads,  
media, actuator, etc.) as this requires special facilities. The drive does not contain user-replaceable  
parts. Opening the HDA for any reason voids your warranty.  
Savvio drives use a dedicated landing zone at the innermost radius of the media to eliminate the possibility of  
destroying or degrading data by landing in the data zone. The heads automatically go to the landing zone when  
power is removed from the drive.  
An automatic shipping lock prevents potential damage to the heads and discs that results from movement dur-  
ing shipping and handling. The shipping lock disengages and the head load process begins when power is  
applied to the drive.  
Savvio drives decode track 0 location data from the servo data embedded on each surface to eliminate  
mechanical transducer adjustments and related reliability concerns.  
The drives also use a high-performance actuator assembly with a low-inertia, balanced, patented, straight arm  
design that provides excellent performance with minimal power dissipation.  
6
Savvio 15K.2 SAS Product Manual, Rev. E  
       
4.1  
Standard features  
Savvio drives have the following standard features:  
• Perpendicular recording technology  
• 1.5 / 3 / 6 Gbit Serial Attached SCSI (SAS) interface  
• Integrated dual port SAS controller supporting the SCSI protocol  
• Support for SAS expanders and fanout adapters  
• Firmware downloadable using the SAS interface  
• 128-deep task set (queue)  
• Supports up to 32 initiators  
• Jumperless configuration  
• User-selectable logical block size (512, 520, 524, or 528 bytes per logical block)  
• Industry standard SFF 2.5-inch dimensions  
• Programmable logical block reallocation scheme  
• Flawed logical block reallocation at format time  
• Programmable auto write and read reallocation  
• Reallocation of defects on command (Post Format)  
• ECC maximum burst correction length of 520 bits  
• No preventive maintenance or adjustments required  
• Dedicated head landing zone  
• Embedded servo design  
• Automatic shipping lock  
• Self diagnostics performed when power is applied to the drive  
• Zone bit recording (ZBR)  
• Vertical, horizontal, or top down mounting  
• Dynamic spindle brake  
• 16 Mbyte data buffer (see Section 5.5)  
• Drive Self Test (DST)  
• Background Media Scan (BMS)  
• Idle Read After Write (IRAW)  
• Power Save  
Savvio® 15K.2 SAS Self-Encrypting Drive models have the following additional features:  
• Automatic data encryption/decryption  
• Controlled access  
• Random number generator  
• Drive locking  
• 16 independent data bands  
• Cryptographic erase of user data for a drive that will be repurposed or scrapped  
• Authenticated firmware download  
4.2  
Media description  
The media used on the drive has an aluminum substrate coated with a thin film magnetic material, overcoated  
with a proprietary protective layer for improved durability and environmental protection.  
Savvio 15K.2 SAS Product Manual, Rev. E  
7
                       
4.3  
Performance  
• Firmware-controlled multisegmented cache designed to dynamically adjust segments for enhanced system  
performance  
• 600 Mbytes/sec maximum instantaneous data transfers  
• 15k RPM spindle. Average latency = 2.0 msec  
• Background processing of queue  
• Supports start and stop commands (spindle stops spinning)  
• Adaptive seek velocity; improved seek performance  
Note. There is no significant performance difference between Self-Encrypting Drive and standard (non-  
Self-Encrypting Drive) models.  
4.4  
Reliability  
• Annualized Failure Rate (AFR) of 0.55%  
• Mean Time Between Failures (MTBF) of 1,600,000 hours  
• Balanced low mass rotary voice coil actuator  
• Incorporates industry-standard Self-Monitoring Analysis and Reporting Technology (S.M.A.R.T.)  
• 5-year warranty  
4.5  
Formatted capacities  
Standard OEM models are formatted to 512 bytes per block. The block size is selectable at format time and  
must be a multiple of 4 bytes. Users having the necessary equipment may modify the data block size before  
issuing a format command and obtain different formatted capacities than those listed.  
To provide a stable target capacity environment and at the same time provide users with flexibility if they  
choose, Seagate recommends product planning in one of two modes:  
Seagate designs capacity points at certain block sizes that Seagate guarantees current and future products will  
meet. We recommend customers use this capacity in their project planning, as it ensures a stable operating  
point with backward and forward compatibility from generation to generation. The current guaranteed operating  
points for this product are:  
Capacity (Blocks)  
ST9146852SS  
ST9146752SS  
ST9146652SS  
ST973452SS  
ST973352SS  
ST973252SS  
Sector Size  
512  
Decimal  
Hex  
Decimal  
Hex  
286,749,488  
280,790,185  
275,154,368  
272,662,935  
11177330  
143,374,744  
140,395,093  
137,577,184  
136,331,467  
88BB998  
520  
10BC84A9  
106685C0  
10408197  
85E4255  
83342E0  
82040CB  
524  
528  
8
Savvio 15K.2 SAS Product Manual, Rev. E  
                 
4.6  
Programmable drive capacity  
Using the Mode Select command, the drive can change its capacity to something less than maximum. See the  
Mode Select (6) parameter list table in the SAS Interface Manual, part number 100293071. A value of zero in  
the Number of Blocks field indicates that the drive will not change the capacity it is currently formatted to have.  
A number other than zero and less than the maximum number of LBAs in the Number of Blocks field changes  
the total drive capacity to the value in the Number of Blocks field. A value greater than the maximum number of  
LBAs is rounded down to the maximum capacity.  
4.7  
Options  
You may order the following items which are incorporated at the manufacturing facility during production or  
packaged before shipping. Some of the options available are (not an exhaustive list of possible options):  
• Other capacities can be ordered depending on sparing scheme and sector size requested.  
• Single-unit shipping pack. The drive is normally shipped in bulk packaging to provide maximum protection  
against transit damage. Units shipped individually require additional protection as provided by the single unit  
shipping pack. Users planning single unit distribution should specify this option.  
• The Safety and Regulatory Agency Specifications, part number 75789512, is usually included with each  
standard OEM drive shipped, but extra copies may be ordered.  
Savvio 15K.2 SAS Product Manual, Rev. E  
9
     
5.0  
Performance characteristics  
This section provides detailed information concerning performance-related characteristics and features of Sav-  
vio drives.  
5.1  
Internal drive characteristics  
ST9146852SS  
ST9146752SS  
ST9146652SS  
146.8  
ST973452SS  
ST973352SS  
ST973252SS  
73.4  
Drive capacity  
Gbytes (formatted, rounded off value)  
Read/write data heads  
Tracks per surface (total)  
Tracks per inch  
Peak bits per inch  
Areal density  
Internal data rate  
Disk rotation speed  
Avg rotational latency  
4
2
60,436  
180,000  
1,317  
237.1  
1,936 - 1,409  
15k  
60,436  
180,000  
1,317  
237.1  
1,936 - 1,409  
15k  
Tracks (user accessible including spare tracks)  
kTPI (average)  
kBPI  
Gbit/in2  
Mbits/sec (variable with zone)  
rpm  
msec  
2.0  
2.0  
5.2  
Seek performance characteristics  
See Section 12.4.1, "SAS physical interface" on page 57 and the SAS Interface Manual (part number  
100293071) for additional timing details.  
5.2.1  
Access time  
1 2  
,
Including controller overhead  
(msec)  
Not including controller overhead1, 2  
(msec)  
Read  
3.1  
Write  
3.5  
Read  
2.9  
Write  
3.3  
3 4  
,
Average  
Typical  
Single track  
Full stroke  
Typical3,4  
Typical3,4  
0.2  
0.42  
5.4  
0.2  
0.42  
5.2  
5.05  
4.85  
1.  
2.  
3.  
Execution time measured from receipt of the Command to the Response.  
Assumes no errors and no sector has been relocated.  
Typical access times are measured under nominal conditions of temperature, voltage, and horizontal orientation as  
measured on a representative sample of drives.  
4.  
Access time = controller overhead + average seek time and applies to all data transfer commands.  
Access to data = access time + latency time.  
10  
Savvio 15K.2 SAS Product Manual, Rev. E  
                                               
5.2.2  
Format command execution time  
ST9146852SS  
ST9146752SS  
ST9146652SS  
ST973452SS  
ST973352SS  
ST973252SS  
Maximum (with verify)  
64 minutes  
48 minutes  
47 minutes  
39 minutes  
Maximum (without verify)  
Execution time measured from receipt of the last byte of the Command Descriptor Block (CDB) to the request  
for a Status Byte Transfer to the Initiator (excluding connect/disconnect).  
When changing sector sizes, the format times shown above may need to be increased by 30 minutes.  
5.2.3  
General performance characteristics  
Sustained transfer rate  
105 to 152 Mbytes/sec  
SAS Interface maximum instantaneous transfer rate  
600 Mbytes/sec* per port  
(dual port = 1,200 Mbytes/sec*)  
Logical block sizes  
512 (default), 520, 524 and 528  
Read/write consecutive sectors on a track  
Yes  
Flaw reallocation performance impact (for flaws reallocated at format time using the  
spare sectors per sparing zone reallocation scheme.)  
Negligible  
Average rotational latency  
2.0 msec  
*Assumes no errors and no relocated logical blocks. Rate measured from the start of the first logical block transfer to or  
from the host.  
5.3  
Start/stop time  
The drive accepts the commands listed in the SAS Interface Manual less than 3 seconds after DC power has  
been applied.  
If the drive receives a NOTIFY (ENABLE SPINUP) primitive through either port and has not received a START  
STOP UNIT command with the START bit equal to 0, the drive becomes ready for normal operations within 20  
seconds (excluding the error recovery procedure).  
If the drive receives a START STOP UNIT command with the START bit equal to 0 before receiving a NOTIFY  
(ENABLE SPINUP) primitive, the drive waits for a START STOP UNIT command with the START bit equal to 1.  
After receiving a START STOP UNIT command with the START bit equal to 1, the drive waits for a NOTIFY  
(ENABLE SPINUP) primitive. After receiving a NOTIFY (ENABLE SPINUP) primitive through either port, the  
drive becomes ready for normal operations within 30 seconds (excluding the error recovery procedure).  
If the drive receives a START STOP UNIT command with the START bit and IMMED bit equal to 1 and does  
not receive a NOTIFY (ENABLE SPINUP) primitive within 5 seconds, the drive fails the START STOP UNIT  
command.  
The START STOP UNIT command may be used to command the drive to stop the spindle. Stop time is 20 sec-  
onds (maximum) from removal of DC power. SCSI stop time is 20 seconds. There is no power control switch  
on the drive.  
Savvio 15K.2 SAS Product Manual, Rev. E  
11  
               
5.4  
Prefetch/multi-segmented cache control  
The drive provides a prefetch (read look-ahead) and multi-segmented cache control algorithms that in many  
cases can enhance system performance. Cache refers to the drive buffer storage space when it is used in  
cache operations. To select this feature, the host sends the Mode Select command with the proper values in  
the applicable bytes in page 08h. Prefetch and cache operations are independent features from the standpoint  
that each is enabled and disabled independently using the Mode Select command; however, in actual opera-  
tion, the prefetch feature overlaps cache operation somewhat as described in sections 5.5.1 and 5.5.2.  
All default cache and prefetch mode parameter values (Mode Page 08h) for standard OEM versions of this  
drive family are given in Table 9.  
5.5  
Cache operation  
Note. Refer to the SAS Interface Manual for more detail concerning the cache bits.  
Of the 16 Mbytes physical buffer space in the drive, approximately 13,000 kbytes can be used as a cache. The  
buffer is divided into logical segments from which data is read and to which data is written.  
The drive keeps track of the logical block addresses of the data stored in each segment of the buffer. If the  
cache is enabled (see RCD bit in the SAS Interface Manual), data requested by the host with a read command  
is retrieved from the buffer, if possible, before any disk access is initiated. If cache operation is not enabled, the  
buffer is still used, but only as circular buffer segments during disk medium read operations (disregarding  
Prefetch operation for the moment). That is, the drive does not check in the buffer segments for the requested  
read data, but goes directly to the medium to retrieve it. The retrieved data merely passes through some buffer  
segment on the way to the host. All data transfers to the host are in accordance with buffer-full ratio rules. See  
the explanation provided with the information about Mode Page 02h (disconnect/reconnect control) in the SAS  
Interface Manual.  
The following is a simplified description of the prefetch/cache operation:  
Case A—read command is received and all of the requested logical blocks are already in the cache:  
1. Drive transfers the requested logical blocks to the initiator.  
Case B—A Read command requests data, and at least one requested logical block is not in any segment of  
the cache:  
1. The drive fetches the requested logical blocks from the disk and transfers them into a segment, and then  
from there to the host in accordance with the Mode Select Disconnect/Reconnect parameters, page 02h.  
2. If the prefetch feature is enabled, refer to section 5.5.2 for operation from this point.  
Each cache segment is actually a self-contained circular buffer whose length is an integer number of logical  
blocks. The drive dynamically creates and removes segments based on the workload. The wrap-around capa-  
bility of the individual segments greatly enhances the cache’s overall performance.  
Note. The size of each segment is not reported by Mode Sense command page 08h, bytes 14 and 15.  
The value 0XFFFF is always reported regardless of the actual size of the segment. Sending a size  
specification using the Mode Select command (bytes 14 and 15) does not set up a new segment  
size. If the STRICT bit in Mode page 00h (byte 2, bit 1) is set to one, the drive responds as it does  
for any attempt to change an unchangeable parameter.  
12  
Savvio 15K.2 SAS Product Manual, Rev. E  
                 
5.5.1  
Caching write data  
Write caching is a write operation by the drive that makes use of a drive buffer storage area where the data to  
be written to the medium is stored while the drive performs the Write command.  
If read caching is enabled (RCD=0), then data written to the medium is retained in the cache to be made avail-  
able for future read cache hits. The same buffer space and segmentation is used as set up for read functions.  
The buffer segmentation scheme is set up or changed independently, having nothing to do with the state of  
RCD. When a write command is issued, if RCD=0, the cache is first checked to see if any logical blocks that  
are to be written are already stored in the cache from a previous read or write command. If there are, the  
respective cache segments are cleared. The new data is cached for subsequent Read commands.  
If the number of write data logical blocks exceed the size of the segment being written into, when the end of the  
segment is reached, the data is written into the beginning of the same cache segment, overwriting the data that  
was written there at the beginning of the operation; however, the drive does not overwrite data that has not yet  
been written to the medium.  
If write caching is enabled (WCE=1), then the drive may return Good status on a write command after the data  
has been transferred into the cache, but before the data has been written to the medium. If an error occurs  
while writing the data to the medium, and Good status has already been returned, a deferred error will be gen-  
erated.  
The Synchronize Cache command may be used to force the drive to write all cached write data to the medium.  
Upon completion of a Synchronize Cache command, all data received from previous write commands will have  
been written to the medium.  
Table 9 shows the mode default settings for the drive.  
5.5.2  
Prefetch operation  
If the Prefetch feature is enabled, data in contiguous logical blocks on the disk immediately beyond that which  
was requested by a Read command are retrieved and stored in the buffer for immediate transfer from the buf-  
fer to the host on subsequent Read commands that request those logical blocks (this is true even if cache  
operation is disabled). Though the prefetch operation uses the buffer as a cache, finding the requested data in  
the buffer is a prefetch hit, not a cache operation hit.  
To enable prefetch, use Mode Select page 08h, byte 12, bit 5 (Disable Read Ahead - DRA bit). DRA bit = 0  
enables prefetch.  
The drive does not use the Max Prefetch field (bytes 8 and 9) or the Prefetch Ceiling field (bytes 10 and 11).  
When prefetch (read look-ahead) is enabled (enabled by DRA = 0), the drive enables prefetch of contiguous  
blocks from the disk when it senses that a prefetch hit will likely occur. The drive disables prefetch when it  
decides that a prefetch hit is not likely to occur.  
Savvio 15K.2 SAS Product Manual, Rev. E  
13  
     
6.0  
Reliability specifications  
The following reliability specifications assume correct host and drive operational interface, including all inter-  
face timings, power supply voltages, environmental requirements and drive mounting constraints.  
Seek error rate:  
Less than 10 errors in 108 seeks  
1
Read Error Rates  
Recovered Data  
Unrecovered Data  
Miscorrected Data  
Less than 1 error in 1012 bits transferred (OEM default settings)  
Less than 1 sector in 1016 bits transferred  
Less than 1 sector in 1021 bits transferred  
Interface error rate:  
Less than 1 error in 1012 bits transferred  
Mean Time Between Failure (MTBF): 1,600,000 hours  
Annualized Failure Rate (AFR)  
Preventive maintenance:  
0.55%  
None required  
1. Error rate specified with automatic retries and data correction with ECC enabled and all flaws reallocated.  
6.1  
Error rates  
The error rates stated in this manual assume the following:  
• The drive is operated in accordance with this manual using DC power as defined in paragraph 7.2, "DC  
• Errors caused by host system failures are excluded from error rate computations.  
• Assume random data.  
• Default OEM error recovery settings are applied. This includes AWRE, ARRE, full read retries, full write  
retries and full retry time.  
6.1.1  
Recoverable Errors  
Recoverable errors are those detected and corrected by the drive, and do not require user intervention.  
Recoverable Data errors will use correction, although ECC on-the-fly is not considered for purposes of recov-  
ered error specifications.  
Recovered Data error rate is determined using read bits transferred for recoverable errors occurring during a  
read, and using write bits transferred for recoverable errors occurring during a write.  
6.1.2  
Unrecoverable Errors  
An unrecoverable data error is defined as a failure of the drive to recover data from the media. These errors  
occur due to head/media or write problems. Unrecoverable data errors are only detected during read opera-  
tions, but not caused by the read. If an unrecoverable data error is detected, a MEDIUM ERROR (03h) in the  
Sense Key will be reported. Multiple unrecoverable data errors resulting from the same cause are treated as 1  
error.  
14  
Savvio 15K.2 SAS Product Manual, Rev. E  
                                   
6.1.3  
Seek errors  
A seek error is defined as a failure of the drive to position the heads to the addressed track. After detecting an  
initial seek error, the drive automatically performs an error recovery process. If the error recovery process fails,  
a seek positioning error (Error code = 15h or 02h) will be reported with a Hardware error (04h) in the Sense  
8
Key. Recoverable seek errors are specified at Less than 10 errors in 10 seeks. Unrecoverable seek errors  
(Sense Key = 04h) are classified as drive failures.  
6.1.4  
Interface errors  
An interface error is defined as a failure of the receiver on a port to recover the data as transmitted by the  
device port connected to the receiver. The error may be detected as a running disparity error, illegal code, loss  
of word sync, or CRC error.  
6.2  
Reliability and service  
You can enhance the reliability of Savvio disk drives by ensuring that the drive receives adequate cooling. Sec-  
tion 7.0 provides temperature measurements and other information that may be used to enhance the service  
life of the drive. Section 11.2 provides recommended air-flow information.  
6.2.1  
Annualized Failure Rate (AFR) and Mean Time Between Failure (MTBF)  
The production disk drive shall achieve an AFR of 0.55% (MTBF of 1,600,000 hours) when operated in an  
environment that ensures the HDA case temperatures do not exceed the values specified in Section 7.4. Oper-  
ation at case temperatures outside the specifications in Section 7.4 may increase the product AFR (decrease  
the MTBF). The AFR (MTBF) is a population statistic not relevant to individual units.  
The AFR (MTBF) specification is based on the following assumptions for Business Critical Storage System  
environments:  
• 8,760 power-on hours per year.  
• 250 average on/off cycles per year.  
• Operations at nominal voltages.  
• Systems will provide adequate cooling to ensure the case temperatures specified in Section 7.4 are not  
exceeded. Temperatures outside the specifications in Section 7.4 will increase the product AFR and  
decrease the MTBF.  
6.2.2  
Preventive maintenance  
No routine scheduled preventive maintenance is required.  
6.2.3  
Hot plugging the drive  
When a disk is powered on by switching the power or hot plugged, the drive runs a self test before attempting  
to communicate on its’ interfaces. When the self test completes successfully, the drive initiates a Link Reset  
starting with OOB. An attached device should respond to the link reset. If the link reset attempt fails, or any  
time the drive looses sync, the drive initiated link reset. The drive will initiate link reset once per second but  
alternates between port A and B. Therefore each port will attempt a link reset once per 2 seconds assuming  
both ports are out of sync.  
If the self-test fails, the drive does not respond to link reset on the failing port.  
Note. It is the responsibility of the systems integrator to assure that no temperature, energy, voltage haz-  
ard, or ESD potential hazard is presented during the hot connect/disconnect operation. Discharge  
the static electricity from the drive carrier prior to inserting it into the system.  
Savvio 15K.2 SAS Product Manual, Rev. E  
15  
                         
Caution. The drive motor must come to a complete stop prior to changing the plane of operation. This time is  
required to insure data integrity.  
6.2.4  
S.M.A.R.T.  
S.M.A.R.T. is an acronym for Self-Monitoring Analysis and Reporting Technology. This technology is intended  
to recognize conditions that indicate imminent drive failure and is designed to provide sufficient warning of a  
failure to allow you to back up the data before an actual failure occurs.  
Note. The drive’s firmware monitors specific attributes for degradation over time but can’t predict instanta-  
neous drive failures.  
Each monitored attribute has been selected to monitor a specific set of failure conditions in the operating per-  
formance of the drive and the thresholds are optimized to minimize “false” and “failed” predictions.  
Controlling S.M.A.R.T.  
The operating mode of S.M.A.R.T. is controlled by the DEXCPT and PERF bits on the Informational Exceptions  
Control mode page (1Ch). Use the DEXCPT bit to enable or disable the S.M.A.R.T. feature. Setting the DEX-  
CPT bit disables all S.M.A.R.T. functions. When enabled, S.M.A.R.T. collects on-line data as the drive performs  
normal read and write operations. When the PERF bit is set, the drive is considered to be in “On-line Mode  
Only” and will not perform off-line functions.  
You can measure off-line attributes and force the drive to save the data by using the Rezero Unit command.  
Forcing S.M.A.R.T. resets the timer so that the next scheduled interrupt is in two hours.  
You can interrogate the drive through the host to determine the time remaining before the next scheduled mea-  
surement and data logging process occurs. To accomplish this, issue a Log Sense command to log page 0x3E.  
This allows you to control when S.M.A.R.T. interruptions occur. Forcing S.M.A.R.T. with the RTZ command  
resets the timer.  
Performance impact  
S.M.A.R.T. attribute data is saved to the disk so that the events that caused a predictive failure can be recre-  
ated. The drive measures and saves parameters once every two hours subject to an idle period on the drive  
interfaces. The process of measuring off-line attribute data and saving data to the disk is uninterruptable. The  
maximum on-line only processing delay is summarized below:  
Maximum processing delay  
On-line only delay  
Fully-enabled delay  
DEXCPT = 0, PERF = 1  
DEXCPT = 0, PERF = 0  
S.M.A.R.T. delay times  
118 milliseconds  
146 milliseconds  
Reporting control  
Reporting is controlled by the MRIE bits in the Informational Exceptions Control mode page (1Ch). Subject to  
the reporting method, the firmware will issue to the host an 01-5Dxx sense code. The error code is preserved  
through bus resets and power cycles.  
Determining rate  
S.M.A.R.T. monitors the rate at which errors occur and signals a predictive failure if the rate of degraded errors  
increases to an unacceptable level. To determine rate, error events are logged and compared to the number of  
total operations for a given attribute. The interval defines the number of operations over which to measure the  
rate. The counter that keeps track of the current number of operations is referred to as the Interval Counter.  
16  
Savvio 15K.2 SAS Product Manual, Rev. E  
   
S.M.A.R.T. measures error rates. All errors for each monitored attribute are recorded. A counter keeps track of  
the number of errors for the current interval. This counter is referred to as the Failure Counter.  
Error rate is the number of errors per operation. The algorithm that S.M.A.R.T. uses to record rates of error is to  
set thresholds for the number of errors and their interval. If the number of errors exceeds the threshold before  
the interval expires, the error rate is considered to be unacceptable. If the number of errors does not exceed  
the threshold before the interval expires, the error rate is considered to be acceptable. In either case, the inter-  
val and failure counters are reset and the process starts over.  
Predictive failures  
S.M.A.R.T. signals predictive failures when the drive is performing unacceptably for a period of time. The firm-  
ware keeps a running count of the number of times the error rate for each attribute is unacceptable. To accom-  
plish this, a counter is incremented each time the error rate is unacceptable and decremented (not to exceed  
zero) whenever the error rate is acceptable. If the counter continually increments such that it reaches the pre-  
dictive threshold, a predictive failure is signaled. This counter is referred to as the Failure History Counter.  
There is a separate Failure History Counter for each attribute.  
6.2.5  
Thermal monitor  
Savvio drives implement a temperature warning system which:  
1. Signals the host if the temperature exceeds a value which would threaten the drive.  
2. Signals the host if the temperature exceeds a user-specified value.  
3. Saves a S.M.A.R.T. data frame on the drive which exceeds the threatening temperature value.  
A temperature sensor monitors the drive temperature and issues a warning over the interface when the tem-  
perature exceeds a set threshold. The temperature is measured at power-up and then at ten-minute intervals  
after power-up.  
The thermal monitor system generates a warning code of 01-0B01 when the temperature exceeds the speci-  
fied limit in compliance with the SCSI standard. The drive temperature is reported in the FRU code field of  
mode sense data. You can use this information to determine if the warning is due to the temperature exceeding  
the drive threatening temperature or the user-specified temperature.  
This feature is controlled by the Enable Warning (EWasc) bit, and the reporting mechanism is controlled by the  
Method of Reporting Informational Exceptions field (MRIE) on the Informational Exceptions Control (IEC)  
mode page (1Ch).  
The current algorithm implements two temperature trip points. The first trip point is set at 65°C which is the  
maximum temperature limit according to the drive specification. The second trip point is user-selectable using  
the Log Select command. The reference temperature parameter in the temperature log page (see Table 1) can  
be used to set this trip point. The default value for this drive is 65°C, however, you can set it to any value in the  
range of 0 to 65°C. If you specify a temperature greater than 65°C in this field, the temperature is rounded  
down to 65°C. A sense code is sent to the host to indicate the rounding of the parameter field.  
Table 1:  
Temperature Log Page (0Dh)  
Parameter Code  
Description  
0000h  
0001h  
Primary Temperature  
Reference Temperature  
Savvio 15K.2 SAS Product Manual, Rev. E  
17  
   
6.2.6  
Drive Self Test (DST)  
Drive Self Test (DST) is a technology designed to recognize drive fault conditions that qualify the drive as a  
failed unit. DST validates the functionality of the drive at a system level.  
There are two test coverage options implemented in DST:  
1. Extended test  
2. Short test  
The most thorough option is the extended test that performs various tests on the drive and scans every logical  
block address (LBA) of the drive. The short test is time-restricted and limited in length—it does not scan the  
entire media surface, but does some fundamental tests and scans portions of the media.  
If DST encounters an error during either of these tests, it reports a fault condition. If the drive fails the test,  
remove it from service and return it to Seagate for service.  
6.2.6.1  
DST failure definition  
The drive will present a “diagnostic failed” condition through the self-tests results value of the diagnostic log  
page if a functional failure is encountered during DST. The channel and servo parameters are not modified to  
test the drive more stringently, and the number of retries are not reduced. All retries and recovery processes  
are enabled during the test. If data is recoverable, no failure condition will be reported regardless of the number  
of retries required to recover the data.  
The following conditions are considered DST failure conditions:  
• Seek error after retries are exhausted  
• Track-follow error after retries are exhausted  
• Read error after retries are exhausted  
• Write error after retries are exhausted  
Recovered errors will not be reported as diagnostic failures.  
6.2.6.2  
Implementation  
This section provides all of the information necessary to implement the DST function on this drive.  
6.2.6.2.1  
State of the drive prior to testing  
The drive must be in a ready state before issuing the Send Diagnostic command. There are multiple reasons  
why a drive may not be ready, some of which are valid conditions, and not errors. For example, a drive may be  
in process of doing a format, or another DST. It is the responsibility of the host application to determine the “not  
ready” cause.  
While not technically part of DST, a Not Ready condition also qualifies the drive to be returned to Seagate as a  
failed drive.  
A Drive Not Ready condition is reported by the drive under the following conditions:  
• Motor will not spin  
• Motor will not lock to speed  
• Servo will not lock on track  
• Drive cannot read configuration tables from the disk  
In these conditions, the drive responds to a Test Unit Ready command with an 02/04/00 or 02/04/03 code.  
6.2.6.2.2  
Invoking DST  
To invoke DST, submit the Send Diagnostic command with the appropriate Function Code (001b for the short  
test or 010b for the extended test) in bytes 1, bits 5, 6, and 7.  
18  
Savvio 15K.2 SAS Product Manual, Rev. E  
 
6.2.6.2.3  
Short and extended tests  
DST has two testing options:  
1. short  
2. extended  
These testing options are described in the following two subsections.  
Each test consists of three segments: an electrical test segment, a servo test segment, and a read/verify scan  
segment.  
Short test (Function Code: 001b)  
The purpose of the short test is to provide a time-limited test that tests as much of the drive as possible within  
120 seconds. The short test does not scan the entire media surface, but does some fundamental tests and  
scans portions of the media. A complete read/verify scan is not performed and only factual failures will report a  
fault condition. This option provides a quick confidence test of the drive.  
Extended test (Function Code: 010b)  
The objective of the extended test option is to empirically test critical drive components. For example, the seek  
tests and on-track operations test the positioning mechanism. The read operation tests the read head element  
and the media surface. The write element is tested through read/write/read operations. The integrity of the  
media is checked through a read/verify scan of the media. Motor functionality is tested by default as a part of  
these tests.  
The anticipated length of the Extended test is reported through the Control Mode page.  
6.2.6.2.4  
Log page entries  
When the drive begins DST, it creates a new entry in the Self-test Results Log page. The new entry is created  
by inserting a new self-test parameter block at the beginning of the self-test results log parameter section of the  
log page. Existing data will be moved to make room for the new parameter block. The drive reports 20 param-  
eter blocks in the log page. If there are more than 20 parameter blocks, the least recent parameter block will be  
deleted. The new parameter block will be initialized as follows:  
1. The Function Code field is set to the same value as sent in the DST command  
2. The Self-Test Results Value field is set to Fh  
3. The drive will store the log page to non-volatile memory  
After a self-test is complete or has been aborted, the drive updates the Self-Test Results Value field in its Self-  
Test Results Log page in non-volatile memory. The host may use Log Sense to read the results from up to the  
last 20 self-tests performed by the drive. The self-test results value is a 4-bit field that reports the results of the  
test. If the field is set to zero, the drive passed with no errors detected by the DST. If the field is not set to zero,  
the test failed for the reason reported in the field.  
The drive will report the failure condition and LBA (if applicable) in the Self-test Results Log parameter. The  
Sense key, ASC, ASCQ, and FRU are used to report the failure condition.  
6.2.6.2.5  
Abort  
There are several ways to abort a diagnostic. You can use a SCSI Bus Reset or a Bus Device Reset message  
to abort the diagnostic.  
You can abort a DST executing in background mode by using the abort code in the DST Function Code field.  
This will cause a 01 (self-test aborted by the application client) code to appear in the self-test results values  
log. All other abort mechanisms will be reported as a 02 (self-test routine was interrupted by a reset condition).  
Savvio 15K.2 SAS Product Manual, Rev. E  
19  
6.2.7  
Product warranty  
Beginning on the date of shipment to the customer and continuing for the period specified in your purchase  
contract, Seagate warrants that each product (including components and subassemblies) that fails to function  
properly under normal use due to defect in materials or workmanship or due to nonconformance to the applica-  
ble specifications will be repaired or replaced, at Seagate’s option and at no charge to the customer, if returned  
by customer at customer’s expense to Seagate’s designated facility in accordance with Seagate’s warranty  
procedure. Seagate will pay for transporting the repair or replacement item to the customer. For more detailed  
warranty information, refer to the standard terms and conditions of purchase for Seagate products on your pur-  
chase documentation.  
The remaining warranty for a particular drive can be determined by calling Seagate Customer Service at  
1-800-468-3472. You can also determine remaining warranty using the Seagate web site (www.seagate.com).  
The drive serial number is required to determine remaining warranty information.  
Shipping  
When transporting or shipping a drive, use only a Seagate-approved container. Keep your original box. Sea-  
gate approved containers are easily identified by the Seagate Approved Package label. Shipping a drive in a  
non-approved container voids the drive warranty.  
Seagate repair centers may refuse receipt of components improperly packaged or obviously damaged in tran-  
sit. Contact your authorized Seagate distributor to purchase additional boxes. Seagate recommends shipping  
by an air-ride carrier experienced in handling computer equipment.  
Product repair and return information  
Seagate customer service centers are the only facilities authorized to service Seagate drives. Seagate does  
not sanction any third-party repair facilities. Any unauthorized repair or tampering with the factory seal voids  
the warranty.  
20  
Savvio 15K.2 SAS Product Manual, Rev. E  
             
7.0  
Physical/electrical specifications  
This section provides information relating to the physical and electrical characteristics of the drive.  
7.1  
AC power requirements  
None.  
7.2  
DC power requirements  
The voltage and current requirements for a single drive are shown below. Values indicated apply at the drive  
connector.  
The standard drive models and the SED drive models have identical hardware, however the security and  
encryption portion of the drive controller ASIC is enabled and functional in the SED models. This represents a  
small additional drain on the 5V supply of about 30mA and a commensurate increase of about 150mW in  
power consumption. There is no additional drain on the 12V supply.  
Savvio 15K.2 SAS Product Manual, Rev. E  
21  
                 
Table 2:  
146GB models DC power requirements  
3.0 Gbit mode  
(Amps)  
+5V  
6.0 Gbit mode  
(Amps)  
+5V  
Notes  
(Amps)  
+12V [2]  
±5% [2]  
0.21  
(Amps)  
+12V [2]  
±5% [2]  
0.21  
Voltage  
Regulation  
[5]  
±5%  
±5%  
Avg idle current DC  
Maximum starting current  
(peak DC) DC  
[1] [7]  
0.36  
0.37  
3σ  
3σ  
3σ  
[3]  
0.51  
0.93  
0.56  
1.12  
1.77  
0.05  
0.51  
0.90  
0.57  
1.12  
1.79  
0.06  
(peak AC) AC  
[3]  
Delayed motor start (max) DC  
Peak operating current: (random read)  
Typical DC  
[1] [4]  
[1] [6]  
[1]  
0.45  
0.47  
1.14  
0.41  
0.41  
1.24  
0.46  
0.48  
1.16  
0.41  
0.41  
1.22  
Maximum DC  
3σ  
Maximum (peak) DC  
Peak operating current: (random write)  
Typical DC  
3σ  
[1]  
[1]  
0.51  
0.54  
1.16  
0.32  
0.33  
1.22  
0.53  
0.55  
1.16  
0.32  
0.32  
1.20  
Maximum DC  
3σ  
Maximum (peak) DC  
Peak operating current: (sequential read)  
Typical DC  
3σ  
[1]  
[1]  
0.88  
0.90  
1.20  
0.22  
0.22  
0.48  
0.90  
0.92  
1.22  
0.22  
0.22  
0.46  
Maximum DC  
3σ  
Maximum (peak) DC  
Peak operating current: (sequential write)  
Typical DC  
3σ  
[1]  
[1]  
0.86  
0.92  
1.18  
0.22  
0.22  
0.46  
0.87  
0.93  
1.18  
0.22  
0.22  
0.46  
Maximum DC  
3σ  
Maximum (peak) DC  
3σ  
22  
Savvio 15K.2 SAS Product Manual, Rev. E  
         
Table 3:  
73GB models DC power requirements  
3.0 Gbit mode  
(Amps)  
+5V  
6.0 Gbit mode  
(Amps)  
+5V  
Notes  
(Amps)  
+12V [2]  
±5% [2]  
0.18  
(Amps)  
+12V [2]  
±5% [2]  
0.18  
Voltage  
Regulation  
[5]  
±5%  
±5%  
Avg idle current DC  
Maximum starting current  
(peak DC) DC  
[1] [7]  
0.36  
0.37  
3σ  
3σ  
3σ  
[3]  
0.51  
0.93  
0.56  
1.09  
1.73  
0.06  
0.51  
0.99  
0.57  
1.08  
1.86  
0.05  
(peak AC) AC  
[3]  
Delayed motor start (max) DC  
Peak operating current: (random read)  
Typical DC  
[1] [4]  
[1]  
0.45  
0.47  
1.16  
0.36  
0.37  
1.16  
0.46  
0.48  
1.14  
0.36  
0.37  
1.16  
Maximum DC  
3σ  
Maximum (peak) DC  
Peak operating current: (random write)  
Typical DC  
3σ  
[1]  
[1]  
0.52  
0.55  
1.14  
0.28  
0.28  
1.18  
0.53  
0.56  
1.16  
0.28  
0.28  
1.20  
Maximum DC  
3σ  
Maximum (peak) DC  
Peak operating current: (sequential read)  
Typical DC  
3σ  
[1]  
[1]  
0.88  
0.92  
1.18  
0.18  
0.19  
0.40  
0.89  
0.93  
1.20  
0.18  
0.19  
0.42  
Maximum DC  
3σ  
Maximum (peak) DC  
Peak operating current: (sequential write)  
Typical DC  
3σ  
[1]  
[1]  
0.88  
0.94  
1.16  
0.18  
0.19  
0.40  
0.89  
0.95  
1.18  
0.18  
0.19  
0.40  
Maximum DC  
3σ  
Maximum (peak) DC  
3σ  
[1] Measured with average reading DC ammeter. Instantaneous +12V current peaks will exceed these val-  
ues. Power supply at nominal voltage. N (number of drives tested) = 6, 35 Degrees C ambient.  
[2] For +12 V, a –10% tolerance is allowed during initial spindle start but must return to ±5% before reaching  
15k RPM. The ±5% must be maintained after the drive signifies that its power-up sequence has been  
completed and that the drive is able to accept selection by the host initiator.  
[3] See +12V current profile in Figure 1.  
[4] This condition occurs after OOB and Speed Negotiation completes but before the drive has received the  
Notify Spinup primitive.  
[5] See paragraph 7.2.1, "Conducted noise immunity." Specified voltage tolerance includes ripple, noise, and  
transient response.  
[6] Operating condition is defined as random 8 block reads.  
[7] During idle, the drive heads are relocated every 60 seconds to a random location within the band from  
three-quarters to maximum track.  
Savvio 15K.2 SAS Product Manual, Rev. E  
23  
           
General DC power requirement notes.  
1. Minimum current loading for each supply voltage is not less than 1.7% of the maximum operating current  
shown.  
2. The +5V and +12V supplies should employ separate ground returns.  
3. Where power is provided to multiple drives from a common supply, careful consideration for individual  
drive power requirements should be noted. Where multiple units are powered on simultaneously, the peak  
starting current must be available to each device.  
4. Parameters, other than spindle start, are measured after a 10-minute warm up.  
5. No terminator power.  
7.2.1  
Conducted noise immunity  
Noise is specified as a periodic and random distribution of frequencies covering a band from DC to 10 MHz.  
Maximum allowed noise values given below are peak-to-peak measurements and apply at the drive power  
connector.  
+5V  
=
=
250 mV pp from 100 Hz to 20 MHz.  
+12V  
800 mV pp from 100 0Hz to 8 KHz.  
450 mV pp from 8 KHz to 20 KHz.  
250 mV pp from 20 KHz to 5 MHz.  
7.2.2  
Power sequencing  
The drive does not require power sequencing. The drive protects against inadvertent writing during power-up  
and down.  
24  
Savvio 15K.2 SAS Product Manual, Rev. E  
         
7.2.3  
Current profiles  
The +12V and +5V current profiles for the Savvio 15K.2 SAS drives are shown below.  
Figure 1. Current profile for 146GB models.  
Savvio 15K.2 SAS Product Manual, Rev. E  
25  
     
Figure 2.  
Current profile for 73GB models  
Note: All times and currents are typical. See Tables 2 and 3 for maximum current requirements.  
26  
Savvio 15K.2 SAS Product Manual, Rev. E  
 
7.3  
Power dissipation  
146GB models in 6.0 Gbit operation  
Typical power dissipation under idle conditions in 6.0 Gb operation is 4.37 watts (14.91 BTUs per hour).  
To obtain operating power for typical random read operations, refer to the following I/O rate curve (see Figure  
3). Locate the typical I/O rate for a drive in your system on the horizontal axis and read the corresponding +5  
volt current, +12 volt current, and total watts on the vertical axis. To calculate BTUs per hour, multiply watts by  
3.4123.  
Figure 3.  
146GB models (6.0 Gbit) DC current and power vs. input/output operations per second  
146GB models in 3.0 Gbit operation  
Typical power dissipation under idle conditions in 3.0 Gbit operation is 4.32 watts (14.74 BTUs per hour).  
To obtain operating power for typical random read operations, refer to the following I/O rate curve (see Figure  
3). Locate the typical I/O rate for a drive in your system on the horizontal axis and read the corresponding +5  
volt current, +12 volt current, and total watts on the vertical axis. To calculate BTUs per hour, multiply watts by  
3.4123.  
Figure 4.  
146GB models (3.0 Gbit) DC current and power vs. input/output operations per second  
Savvio 15K.2 SAS Product Manual, Rev. E  
27  
       
73GB models in 6.0 Gbit operation  
Typical power dissipation under idle conditions in 6.0 Gb operation is 4.01 watts (13.68 BTUs per hour).  
To obtain operating power for typical random read operations, refer to the following I/O rate curve (see Figure  
3). Locate the typical I/O rate for a drive in your system on the horizontal axis and read the corresponding +5  
volt current, +12 volt current, and total watts on the vertical axis. To calculate BTUs per hour, multiply watts by  
3.4123.  
Figure 5.  
73GB models (6.0 Gbit) DC current and power vs. input/output operations per second  
73GB models in 3.0 Gbit operation  
Typical power dissipation under idle conditions in 3.0 Gbit operation is 3.96 watts (13.51 BTUs per hour).  
To obtain operating power for typical random read operations, refer to the following I/O rate curve (see Figure  
3). Locate the typical I/O rate for a drive in your system on the horizontal axis and read the corresponding +5  
volt current, +12 volt current, and total watts on the vertical axis. To calculate BTUs per hour, multiply watts by  
3.4123.  
Figure 6.  
73GB models (3.0 Gbit) DC current and power vs. input/output operations per second  
28  
Savvio 15K.2 SAS Product Manual, Rev. E  
   
7.4  
Environmental limits  
Temperature and humidity values experienced by the drive must be such that condensation does not occur on  
any drive part. Altitude and atmospheric pressure specifications are referenced to a standard day at 58.7°F  
(14.8°C). Maximum wet bulb temperature is 82°F (28°C).  
7.4.1  
Temperature  
a. Operating  
With cooling designed to maintain the case temperatures, the drive meets all specifications over a 41°F to  
131°F (5°C to 55°C) drive ambient temperature range with a maximum temperature gradient of 20°C per  
hour. The enclosure for the drive should be designed such that these temperatures not exceeded. Air flow  
may be needed to achieve these temperature values (see Section 11.2). Operation at case temperatures  
above these values may adversely affect the drives ability to meet specifications.  
The MTBF specification for the drive is based on operating in an environment that ensures that the case  
temperatures are not exceeded. Occasional excursions to drive ambient temperatures of 131°F (55°C) or  
41°F (5°C) may occur without impact to specified MTBF. Air flow may be needed to achieve these tempera-  
tures. Continual or sustained operation at case temperatures above these values may degrade MTBF. The  
maximum allowable continuous or sustained HDA case temperature for the rated MTBF is 122°F (50°C).  
To confirm that the required cooling for the electronics and HDA is provided, place the drive in its final  
mechanical configuration, perform random write/read operations. After the temperatures stabilize, measure  
the case temperature of the drive.  
The maximum allowable HDA case temperature is 60°C. Operation of the drive at the maximum case tem-  
perature is intended for short time periods only. Continuous operation at the elevated temperatures will  
reduce product reliability.  
b. Non-operating  
–40° to 158°F (–40° to 70°C) package ambient with a maximum gradient of 20°C per hour. This specifica-  
tion assumes that the drive is packaged in the shipping container designed by Seagate for use with drive.  
HDA Temp.  
Check Point  
Figure 7.  
7.4.2  
Location of the HDA temperature check point  
Relative humidity  
The values below assume that no condensation on the drive occurs.  
a. Operating  
5% to 95% non-condensing relative humidity with a maximum gradient of 20% per hour.  
b. Non-operating  
5% to 95% non-condensing relative humidity.  
Savvio 15K.2 SAS Product Manual, Rev. E  
29  
                                         
7.4.3  
Effective altitude (sea level)  
a. Operating  
–1,000 to +10,000 feet (–305 to +3,048 meters)  
b. Non-operating  
–1,000 to +40,000 feet (–305 to +12,192 meters)  
7.4.4  
Shock and vibration  
Shock and vibration limits specified in this document are measured directly on the drive chassis. If the drive is  
installed in an enclosure to which the stated shock and/or vibration criteria is applied, resonances may occur  
internally to the enclosure resulting in drive movement in excess of the stated limits. If this situation is apparent,  
it may be necessary to modify the enclosure to minimize drive movement.  
The limits of shock and vibration defined within this document are specified with the drive mounted by any of  
the four methods shown in Figure 8, and in accordance with the restrictions of Section 11.3.  
7.4.4.1  
Shock  
a. Operating—normal  
The drive, as installed for normal operation, shall operate error free while subjected to intermittent shock not  
exceeding 15 Gs at a maximum duration of 11 msec (half sinewave). The drive, as installed for normal  
operation, shall operate error free while subjected to intermittent shock not exceeding 20 Gs at a maximum  
duration of 2 msec (half sinewave). Shock may be applied in the X, Y, or Z axis.  
b. Operating—abnormal  
Equipment, as installed for normal operation, does not incur physical damage while subjected to intermit-  
tent shock not exceeding 40 Gs at a maximum duration of 11 msec (half sinewave) and 25 Gs as a maxi-  
mum duration of 2 msec (half sinewave). Shock occurring at abnormal levels may promote degraded  
operational performance during the abnormal shock period. Specified operational performance will continue  
when normal operating shock levels resume. Shock may be applied in the X, Y, or Z axis. Shock is not to be  
repeated more than two times per second.  
c. Non-operating  
The limits of non-operating shock shall apply to all conditions of handling and transportation. This includes  
both isolated drives and integrated drives.  
The drive subjected to nonrepetitive shock not exceeding 80 Gs at a maximum duration of 11 msec (half  
sinewave) shall not exhibit device damage or performance degradation. Shock may be applied in the X, Y,  
or Z axis.  
The drive subjected to nonrepetitive shock not exceeding 300 Gs at a maximum duration of 2 msec (half  
sinewave) does not exhibit device damage or performance degradation. Shock may be applied in the X, Y,  
or Z axis.  
The drive subjected to nonrepetitive shock not exceeding 150 Gs at a maximum duration of 0.5 msec (half  
sinewave) does not exhibit device damage or performance degradation. Shock may be applied in the X, Y,  
or Z axis.  
30  
Savvio 15K.2 SAS Product Manual, Rev. E  
                   
d. Packaged  
Disk drives shipped as loose load (not palletized) general freight will be packaged to withstand drops from  
heights as defined in the table below. For additional details refer to Seagate specifications 30190-001  
(under 100 lbs/45 kg) or 30191-001 (over 100 lbs/45 Kg).  
Package size  
Packaged/product weight  
Any  
Drop height  
<600 cu in (<9,800 cu cm)  
600-1800 cu in (9,800-19,700 cu cm)  
>1800 cu in (>19,700 cu cm)  
>600 cu in (>9,800 cu cm)  
60 in (1524 mm)  
48 in (1219 mm)  
42 in (1067 mm)  
36 in (914 mm)  
0-20 lb (0 to 9.1 kg)  
0-20 lb (0 to 9.1 kg)  
20-40 lb (9.1 to 18.1 kg)  
Drives packaged in single or multipacks with a gross weight of 20 pounds (8.95 kg) or less by Seagate for  
general freight shipment shall withstand a drop test from 48 inches (1,070 mm) against a concrete floor or  
equivalent.  
Z
X
Y
X
Z
Y
Figure 8.  
Recommended mounting  
Savvio 15K.2 SAS Product Manual, Rev. E  
31  
       
7.4.4.2  
Vibration  
a. Operating—normal  
The drive as installed for normal operation, shall comply with the complete specified performance while  
subjected to continuous vibration not exceeding  
5 - 500 Hz, swept sine: 0.5 G (zero to peak)  
10 - 500 Hz, random: 0.00051 G2/Hz  
Vibration may be applied in the X, Y, or Z axis.  
b. Operating—abnormal  
Equipment as installed for normal operation shall not incur physical damage while subjected to periodic  
vibration not exceeding:  
15 minutes of duration at major resonant frequency  
5 - 500 Hz, swept sine: 0.75 G (zero to peak)  
10 - 500 Hz, random: 0.0029 G2/Hz  
Vibration occurring at these levels may degrade operational performance during the abnormal vibration  
period. Specified operational performance will continue when normal operating vibration levels are  
resumed. This assumes system recovery routines are available.  
c. Non-operating  
The limits of non-operating vibration shall apply to all conditions of handling and transportation. This  
includes both isolated drives and integrated drives.  
The drive shall not incur physical damage or degraded performance as a result of continuous vibration not  
exceeding:  
5 - 22 Hz, swept sine: 0.25 G, (zero to peak)  
22 - 350 Hz, swept sine: 5.0 G (zero to peak)  
350 - 500 Hz, swept sine: 1.0 G (zero to peak)  
10 - 500 Hz, random: 0.0118 G2/Hz  
Vibration may be applied in the X, Y, or Z axis.  
7.4.5  
Air cleanliness  
The drive is designed to operate in a typical office environment with minimal environmental control.  
7.4.6  
Corrosive environment  
Seagate electronic drive components pass accelerated corrosion testing equivalent to 10 years exposure to  
light industrial environments containing sulfurous gases, chlorine and nitric oxide, classes G and H per ASTM  
B845. However, this accelerated testing cannot duplicate every potential application environment.  
Users should use caution exposing any electronic components to uncontrolled chemical pollutants and corro-  
sive chemicals as electronic drive component reliability can be affected by the installation environment. The sil-  
ver, copper, nickel and gold films used in Seagate products are especially sensitive to the presence of sulfide,  
chloride, and nitrate contaminants. Sulfur is found to be the most damaging. In addition, electronic components  
should never be exposed to condensing water on the surface of the printed circuit board assembly (PCBA) or  
exposed to an ambient relative humidity greater than 95%. Materials used in cabinet fabrication, such as vulca-  
nized rubber, that can outgas corrosive compounds should be minimized or eliminated. The useful life of any  
electronic equipment may be extended by replacing materials near circuitry with sulfide-free alternatives.  
32  
Savvio 15K.2 SAS Product Manual, Rev. E  
                       
7.4.7  
Acoustics  
Sound power during idle mode shall be 3.25 bels typical when measured to ISO 7779 specification.  
Sound power during operating mode shall be 3.35 bels typical when measured to ISO 7779 specification.  
There will not be any discrete tones more than 10 dB above the masking noise on typical drives when mea-  
sured according to Seagate specification 30553-001. There will not be any tones more than 24 dB above the  
masking noise on any drive.  
7.4.8  
Electromagnetic susceptibility  
See Section 3.1.1.1.  
Savvio 15K.2 SAS Product Manual, Rev. E  
33  
       
7.5  
Mechanical specifications  
Refer to Figure 9 for detailed mounting configuration dimensions. See Section 11.3, “Drive mounting.”  
Weight:  
146GB models:  
73GB models:  
0.444 lbs / 0.201 kg  
0.429 lbs / 0.195 kg  
in  
mm  
in  
mm  
in  
mm  
Figure 9.  
Dimensions  
34  
Savvio 15K.2 SAS Product Manual, Rev. E  
         
8.0  
About FIPS  
The Federal Information Processing Standard (FIPS) Publication 140-2, FIPS PUB 140-2, is a U.S. govern-  
ment computer security standard used to accredit cryptographic modules. It is titled “Security Requirements for  
Cryptographic Modules”. The initial publication was on May 25, 2001 and was last updated December 3, 2002.  
Purpose  
The National Institute of Standards and Technology (NIST) issued the FIPS 140 Publication Series to coordi-  
nate the requirements and standards for cryptography modules that include both hardware and software com-  
ponents.  
Federal Information Processing Standard (FIPS) 140-2 Level 2 Certification requires drives to go through gov-  
ernment agencies certifications to add requirements for physical tamper-evidence and role-based authentica-  
tion.  
Level 2 security  
Level 2 improves upon the physical security mechanisms of a Level 1 (lowest level of security) cryptographic  
module by requiring features that show evidence of tampering, including tamper-evident coatings or seals that  
must be broken to attain physical access to the plaintext cryptographic keys and critical security parameters  
(CSPs) within the module, or pick-resistant locks on covers or doors to protect against unauthorized physical  
access.  
Figure 10. Example of FIPS tamper evidence labels.  
Note. Does not represent actual drive.  
Savvio 15K.2 SAS Product Manual, Rev. E  
35  
           
9.0  
About self-encrypting drives  
Self-encrypting drives (SEDs) offer encryption and security services for the protection of stored data, com-  
monly known as “protection of data at rest.” These drives are compliant with the Trusted Computing Group  
(TCG) Enterprise Storage Specifications as detailed in Section 3.2.  
The Trusted Computing Group (TCG) is an organization sponsored and operated by companies in the com-  
puter, storage and digital communications industry. Seagate’s SED models comply with the standards pub-  
lished by the TCG.  
To use the security features in the drive, the host must be capable of constructing and issuing the following two  
SCSI commands:  
• Security Protocol Out  
• Security Protocol In  
These commands are used to convey the TCG protocol to and from the drive in their command payloads.  
9.1  
Data encryption  
Encrypting drives use one inline encryption engine for each port, employing AES-128 data encryption in Cipher  
Block Chaining (CBC) mode to encrypt all data prior to being written on the media and to decrypt all data as it  
is read from the media. The encryption engines are always in operation, cannot be disabled, and do not detract  
in any way from the performance of the drive.  
The 32-byte Data Encryption Key (DEK) is a random number which is generated by the drive, never leaves the  
drive, and is inaccessible to the host system. The DEK is itself encrypted when it is stored on the media and  
when it is in volatile temporary storage (DRAM) external to the encryption engine. A unique data encryption  
key is used for each of the drive's possible16 data bands (see Section 9.5).  
9.2  
Controlled access  
The drive has two security partitions (SPs) called the "Admin SP" and the "Locking SP." These act as gate-  
keepers to the drive security services. Security-related commands will not be accepted unless they also supply  
the correct credentials to prove the requester is authorized to perform the command.  
9.2.1  
Admin SP  
The Admin SP allows the drive's owner to enable or disable firmware download operations (see Section 9.4).  
Access to the Admin SP is available using the SID (Secure ID) password or the MSID (Makers Secure ID)  
password.  
36  
Savvio 15K.2 SAS Product Manual, Rev. E  
                                                     
9.2.2  
Locking SP  
The Locking SP controls read/write access to the media and the cryptographic erase feature. Access to the  
Locking SP is available using the BandMasterX or EraseMaster passwords. Since the drive owner can define  
up to 16 data bands on the drive, each data band has its own password called BandMasterX where X is the  
number of the data band (0 through 15).  
9.2.3  
Default password  
When the drive is shipped from the factory, all passwords are set to the value of MSID. This 32-byte random  
value is printed on the drive label and it can be read by the host electronically over the I/O. After receipt of the  
drive, it is the responsibility of the owner to use the default MSID password as the authority to change all other  
passwords to unique owner-specified values.  
9.3  
Random number generator (RNG)  
The drive has a 32-byte hardware RNG that it is uses to derive encryption keys or, if requested to do so, to pro-  
vide random numbers to the host for system use, including using these numbers as Authentication Keys (pass-  
words) for the drive’s Admin and Locking SPs.  
9.4  
Drive locking  
In addition to changing the passwords, as described in Section 9.2.3, the owner should also set the data  
access controls for the individual bands.  
The variable "LockOnReset" should be set to "PowerCycle" to ensure that the data bands will be locked if  
power is lost. This scenario occurs if the drive is removed from its cabinet. The drive will not honor any data  
read or write requests until the bands have been unlocked. This prevents the user data from being accessed  
without the appropriate credentials when the drive has been removed from its cabinet and installed in another  
system.  
When the drive is shipped from the factory, the firmware download port is locked and the drive will reject any  
attempt to download new firmware. The drive owner must use the SID credential to unlock the firmware down-  
load port before firmware updates will be accepted.  
9.5  
Data bands  
When shipped from the factory, the drive is configured with a single data band called Band 0 (also known as  
the Global Data Band) which comprises LBA 0 through LBA max. The host may allocate Band1 by specifying a  
start LBA and an LBA range. The real estate for this band is taken from the Global Band. An additional 14 Data  
Bands may be defined in a similar way (Band2 through Band15) but before these bands can be allocated LBA  
space, they must first be individually enabled using the EraseMaster password.  
Data bands cannot overlap but they can be sequential with one band ending at LBA (x) and the next beginning  
at LBA (x+1).  
Each data band has its own drive-generated encryption key and its own user-supplied password. The host may  
change the Encryption Key (see Section 9.6) or the password when required. The bands should be aligned to  
4K LBA boundaries.  
Savvio 15K.2 SAS Product Manual, Rev. E  
37  
                                           
9.6  
Cryptographic erase  
A significant feature of SEDs is the ability to perform a cryptographic erase. This involves the host telling the  
drive to change the data encryption key for a particular band. Once changed, the data is no longer recoverable  
since it was written with one key and will be read using a different key. Since the drive overwrites the old key  
with the new one, and keeps no history of key changes, the user data can never be recovered. This is tanta-  
mount to an instantaneous data erase and is very useful if the drive is to be scrapped or redispositioned.  
9.7  
Authenticated firmware download  
In addition to providing a locking mechanism to prevent unwanted firmware download attempts, the drive also  
only accepts download files which have been cryptographically signed by the appropriate Seagate Design  
Center.  
Three conditions must be met before the drive will allow the download operation:  
1. The download must be an SED file. A standard (base) drive (non-SED) file will be rejected.  
2. The download file must be signed and authenticated.  
3. As with a non-SED drive, the download file must pass the acceptance criteria for the drive. For example it  
must be applicable to the correct drive model, and have compatible revision and customer status.  
9.8  
Power requirements  
The standard drive models and the SED drive models have identical hardware, however the security and  
encryption portion of the drive controller ASIC is enabled and functional in the SED models. This represents a  
small additional drain on the 5V supply of about 30mA and a commensurate increase of about 150mW in  
power consumption. There is no additional drain on the 12V supply. See the tables in Section 7.2 for power  
requirements on the standard (non-SED) drive models.  
9.9  
Supported commands  
The SED models support the following two commands in addition to the commands supported by the standard  
(non-SED) models as listed in Table 7:  
• Security Protocol Out (B5h)  
• Security Protocol In (A2h)  
38  
Savvio 15K.2 SAS Product Manual, Rev. E  
         
10.0  
Defect and error management  
Seagate continues to use innovative technologies to manage defects and errors. These technologies are  
designed to increase data integrity, perform drive self-maintenance, and validate proper drive operation.  
SCSI defect and error management involves drive internal defect/error management and SAS system error  
considerations (errors in communications between the initiator and the drive). In addition, Seagate provides  
the following technologies used to increase data integrity and drive reliability:  
• Background Media Scan (see Section 10.4)  
• Media Pre-Scan (see Section 10.5)  
• Deferred Auto-Reallocation (see Section 10.6)  
• Idle Read After Write (see Section 10.7)  
The read error rates and specified storage capacities are not dependent on host (initiator) defect management  
routines.  
10.1  
Drive internal defects/errors  
During the initial drive format operation at the factory, media defects are identified, tagged as being unusable,  
and their locations recorded on the drive primary defects list (referred to as the “P’ list and also as the ETF  
defect list). At factory format time, these known defects are also reallocated, that is, reassigned to a new place  
on the medium and the location listed in the defects reallocation table. The “P” list is not altered after factory  
formatting. Locations of defects found and reallocated during error recovery procedures after drive shipment  
are listed in the “G” list (defects growth list). The “P” and “G” lists may be referenced by the initiator using the  
Read Defect Data command.  
Details of the SCSI commands supported by the drive are described in the SAS Interface Manual. Also, more  
information on the drive Error Recovery philosophy is presented in the SAS Interface Manual.  
10.2  
Drive error recovery procedures  
When an error occurs during drive operation, the drive, if programmed to do so, performs error recovery proce-  
dures to attempt to recover the data. The error recovery procedures used depend on the options previously set  
in the Error Recovery Parameters mode page. Error recovery and defect management may involve using sev-  
eral SCSI commands described in the SAS Interface Manual. The drive implements selectable error recovery  
time limits required in video applications.  
The error recovery scheme supported by the drive provides a way to control the total error recovery time for the  
entire command in addition to controlling the recovery level for a single LBA. The total amount of time spent in  
error recovery for a command can be limited using the Recovery Time Limit bytes in the Error Recovery mode  
page. The total amount of time spent in error recovery for a single LBA can be limited using the Read Retry  
Count or Write Retry Count bytes in the Error Recovery mode page.  
Savvio 15K.2 SAS Product Manual, Rev. E  
39  
                 
The drive firmware error recovery algorithms consists of 11 levels for read recoveries and five levels for write.  
Each level may consist of multiple steps, where a step is defined as a recovery function involving a single re-  
read or re-write attempt. The maximum level used by the drive in LBA recovery is determined by the read and  
write retry counts.  
Table 4 equates the read and write retry count with the maximum possible recovery time for read and write  
recovery of individual LBAs. The times given do not include time taken to perform reallocations. Reallocations  
are performed when the ARRE bit (for reads) or AWRE bit (for writes) is one, the RC bit is zero, and the recov-  
ery time limit for the command has not yet been met. Time needed to perform reallocation is not counted  
against the recovery time limit.  
When the RC bit is one, reallocations are disabled even if the ARRE or AWRE bits are one. The drive will still  
perform data recovery actions within the limits defined by the Read Retry Count, Write Retry Count, and  
Recovery Time Limit parameters. However, the drive does not report any unrecovered errors.  
Table 4:  
Read and write retry count maximum recovery times  
Maximum recovery time per  
Maximum recovery time per  
LBA (cumulative, msec)  
Read retry count LBA (cumulative, msec)  
Write retry count  
0
51.87  
0
23.94  
35.91  
39.9  
1
59.85  
1
2
203.49  
231.42  
295.26  
327.18  
359.10  
446.88  
538.65  
570.57  
598.50  
1,534.97  
2
3
3
51.87  
79.8  
4
4
5
5 (default)  
107.73  
6
7
8
9
10  
11 (default)  
Setting these retry counts to a value below the default setting could result in degradation of the unrecovered  
error rate. For example, suppose the read/write recovery page has the RC bit set to 0, read retry count set to 4,  
and the recovery time limit set to 450. A four LBA Read command is allowed to take up to 295.26 msec recov-  
ery time for each block and a maximum of 450 msec recovery for all four blocks. If either of these limits is  
reached and a block has not yet been recovered, the command will end with Check Condition status and an  
unrecoverable read error will be reported.  
10.3  
SAS system errors  
Information on the reporting of operational errors or faults across the interface is given in the SAS Interface  
Manual. The SSP Response returns information to the host about numerous kinds of errors or faults. The  
Receive Diagnostic Results reports the results of diagnostic operations performed by the drive.  
Status returned by the drive to the initiator is described in the SAS Interface Manual. Status reporting plays a  
role in systems error management and its use in that respect is described in sections where the various com-  
mands are discussed.  
40  
Savvio 15K.2 SAS Product Manual, Rev. E  
   
10.4  
Background Media Scan  
Background Media Scan (BMS) is a self-initiated media scan. BMS is defined in the T10 document SPC-4  
available from the T10 committee. BMS performs sequential reads across the entire pack of the media while  
the drive is idle. In RAID arrays, BMS allows hot spare drives to be scanned for defects prior to being put into  
service by the host system. On regular duty drives, if the host system makes use of the BMS Log Page, it can  
avoid placing data in suspect locations on the media. Unreadable and recovered error sites will be logged or  
reallocated per ARRE/AWRE settings.  
With BMS, the host system can consume less power and system overhead by only checking BMS status and  
results rather than tying up the bus and consuming power in the process of host-initiated media scanning activ-  
ity.  
Since the background scan functions are only done during idle periods, BMS causes a negligible impact to sys-  
tem performance. The first BMS scan for a newly manufactured drive is performed as quickly as possible to  
verify the media and protect data by setting the “Start time after idle” to 5ms, all subsequent scans begin after  
500ms of idle time. Other features that normally use idle time to function will function normally because BMS  
functions for bursts of 800ms and then suspends activity for 100ms to allow other background functions to  
operate.  
BMS interrupts immediately to service host commands from the interface bus while performing reads. BMS will  
complete any BMS-initiated error recovery prior to returning to service host-initiated commands. Overhead  
associated with a return to host-servicing activity from BMS only impacts the first command that interrupted  
BMS, this results in a typical delay of about 1 ms.  
10.5  
Media Pre-Scan  
Media Pre-Scan is a feature that allows the drive to repair media errors that would otherwise have been found  
by the host system during critical data accesses early in the drive’s life. The default setting for Media Pre-Scan  
is enabled on standard products. Media Pre-Scan checks each write command to determine if the destination  
LBAs have been scanned by BMS. If the LBAs have been verified, the drive proceeds with the normal write  
command. If the LBAs have not been verified by BMS, Pre-Scan will convert the write to a write verify to certify  
that the data was properly written to the disk.  
Note. During Pre-Scan write verify commands, write performance may decrease by 50% until Pre-Scan  
completes. Write performance testing should be performed after Pre-Scan is complete. This may  
be checked by reading the BMS status.  
To expedite the scan of the full pack and subsequently exit from the Pre-Scan period, BMS will begin scanning  
immediately when the drive goes to idle during the Pre-Scan period. In the event that the drive is in a high  
transaction traffic environment and is unable to complete a BMS scan within 24 power on hours BMS will dis-  
able Pre-Scan to restore full performance to the system.  
10.6  
Deferred Auto-Reallocation  
Deferred Auto-Reallocation (DAR) simplifies reallocation algorithms at the system level by allowing the drive to  
reallocate unreadable locations on a subsequent write command. Sites are marked for DAR during read oper-  
ations performed by the drive. When a write command is received for an LBA marked for DAR, the auto-reallo-  
cation process is invoked and attempts to rewrite the data to the original location. If a verification of this rewrite  
fails, the sector is re-mapped to a spare location.  
This is in contrast to the system having to use the Reassign Command to reassign a location that was unread-  
able and then generate a write command to rewrite the data. DAR is most effective when AWRE and ARRE  
are enabled—this is the default setting from the Seagate factory. With AWRE and ARRE disabled DAR is  
unable to reallocate the failing location and will report an error sense code indicating that a write command is  
being attempted to a previously failing location.  
Savvio 15K.2 SAS Product Manual, Rev. E  
41  
               
10.7  
Idle Read After Write  
Idle Read After Write (IRAW) utilizes idle time to verify the integrity of recently written data. During idle periods,  
no active system requests, the drive reads recently written data from the media and compares it to valid write  
command data resident in the drives data buffer. Any sectors that fail the comparison result in the invocation of  
a rewrite and auto-reallocation process. The process attempts to rewrite the data to the original location. If a  
verification of this rewrite fails, the sector is re-mapped to a spare location.  
42  
Savvio 15K.2 SAS Product Manual, Rev. E  
     
11.0  
Installation  
Savvio disk drive installation is a plug-and-play process. There are no jumpers, switches, or terminators on the  
drive.  
SAS drives are designed to be used in a host system that provides a SAS-compatible backplane with bays  
designed to accommodate the drive. In such systems, the host system typically provides a carrier or tray into  
which you need to mount the drive. Mount the drive to the carrier or tray provided by the host system using four  
M3 x 0.5 metric screws. When tightening the screws, use a maximum torque of 4.5 in-lb +/- 0.45 in-lb. Do not  
over-tighten or force the screws. You can mount the drive in any orientation.  
Note. SAS drives are designed to be attached to the host system without I/O or power cables. If you  
intend the use the drive in a non-backplane host system, connecting the drive using high-quality  
cables is acceptable as long as the I/O cable length does not exceed 4 meters (13.1 feet).  
Slide the carrier or tray into the appropriate bay in your host system using the instructions provided by the host  
system. This connects the drive directly to your system’s SAS connector. The SAS connector is normally  
located on a SAS backpanel. See Section 12.4.1 for additional information about these connectors.  
Power is supplied through the SAS connector.  
The drive is shipped from the factory low-level formatted in 512-byte logical blocks. You need to reformat the  
drive only if you want to select a different logical block size.  
Figure 11. Physical interface  
11.1  
Drive orientation  
The drive may be mounted in any orientation. All drive performance characterizations, however, have been  
done with the drive in horizontal (disks level) and vertical (drive on its side) orientations, which are the two pre-  
ferred mounting orientations.  
Savvio 15K.2 SAS Product Manual, Rev. E  
43  
               
11.2  
Cooling  
Cabinet cooling must be designed by the customer so that the ambient temperature immediately surrounding  
the drive will not exceed temperature conditions specified in Section 7.4.1, "Temperature."  
The rack, cabinet, or drawer environment for the drive must provide heat removal from the electronics and  
head and disk assembly (HDA). You should confirm that adequate heat removal is provided using the temper-  
ature measurement guidelines described in Section 7.4.1.  
Forced air flow may be required to keep temperatures at or below the temperatures specified in Section 7.4.1  
in which case the drive should be oriented, or air flow directed, so that the least amount of air flow resistance is  
created while providing air flow to the electronics and HDA. Also, the shortest possible path between the air  
inlet and exit should be chosen to minimize the travel length of air heated by the drive and other heat sources  
within the rack, cabinet, or drawer environment.  
If forced air is determined to be necessary, possible air-flow patterns are shown in Figure 12. The air-flow pat-  
terns are created by one or more fans, either forcing or drawing air as shown in the illustrations. Conduction,  
convection, or other forced air-flow patterns are acceptable as long as the temperature measurement guide-  
lines of Section 7.4.1 are met.  
Above unit  
Under unit  
Note. Air flows in the direction shown (back to front)  
or in reverse direction (front to back)  
Above unit  
Under unit  
Note. Air flows in the direction shown or  
in reverse direction (side to side)  
Figure 12. Air flow  
44  
Savvio 15K.2 SAS Product Manual, Rev. E  
                         
11.3  
Drive mounting  
Mount the drive using the bottom or side mounting holes. If you mount the drive using the bottom holes, ensure  
that you do not physically distort the drive by attempting to mount it on a stiff, non-flat surface.  
The allowable mounting surface stiffness is 80 lb/in (14.0 N/mm). The following equation and paragraph define  
the allowable mounting surface stiffness:  
K x X = F < 15lb = 67N  
where K is the mounting surface stiffness (units in lb/in or N/mm) and X is the out-of-plane surface distortion  
(units in inches or millimeters). The out-of-plane distortion (X) is determined by defining a plane with three of  
the four mounting points fixed and evaluating the out-of-plane deflection of the fourth mounting point when a  
known force (F) is applied to the fourth point.  
11.4  
Grounding  
Signal ground (PCBA) and HDA ground are connected together in the drive and cannot be separated by the  
user. The equipment in which the drive is mounted is connected directly to the HDA and PCBA with no electri-  
cally isolating shock mounts. If it is desired for the system chassis to not be connected to the HDA/PCBA  
ground, the systems integrator or user must provide a nonconductive (electrically isolating) method of mount-  
ing the drive in the host equipment.  
Increased radiated emissions may result if you do not provide the maximum surface area ground connection  
between system ground and drive ground. This is the system designer’s and integrator’s responsibility.  
Savvio 15K.2 SAS Product Manual, Rev. E  
45  
                         
12.0  
Interface requirements  
This section partially describes the interface requirements as implemented on Savvio drives. Additional infor-  
mation is provided in the SAS Interface Manual (part number 100293071).  
12.1  
SAS features  
This section lists the SAS-specific features supported by Savvio drives.  
12.1.1  
Task management functions  
Table 5 lists the SAS task management functions supported.  
Table 5:  
SAS task management functions supported  
Task name  
Abort Task  
Supported  
Yes  
Clear ACA  
Yes  
Clear task set  
Abort task set  
Yes  
Yes  
Logical Unit Reset  
Query Task  
Yes  
Yes  
12.1.2  
Task management responses  
Table 6 lists the SAS response codes returned for task management functions supported.  
Table 6:  
Task management response codes  
Function name  
Function complete  
Invalid frame  
Response code  
00  
02  
04  
05  
08  
09  
Function not supported  
Function failed  
Function succeeded  
Invalid logical unit  
46  
Savvio 15K.2 SAS Product Manual, Rev. E  
                                 
12.2  
Dual port support  
Savvio SAS drives have two independent ports. These ports may be connected in the same or different SCSI  
domains. Each drive port has a unique SAS address.  
The two ports have the capability of independent port clocking (e.g. both ports can run at 6Gbit/sec or the first  
port can run at 6Gbit/sec while the second port runs at 3Gbit/sec.) The supported link rates are 1.5, 3.0, or 6.0  
Gbits/sec.  
Subject to buffer availability, the Savvio drives support:  
• Concurrent port transfers—The drive supports receiving COMMAND, TASK management transfers on both  
ports at the same time.  
• Full duplex—The drive supports sending XFER_RDY, DATA and RESPONSE transfers while receiving  
frames on both ports.  
Savvio 15K.2 SAS Product Manual, Rev. E  
47  
   
12.3  
SCSI commands supported  
Table 7 lists the SCSI commands supported by Savvio drives.  
Table 7: Supported commands  
Command name  
Command code  
Supported  
Change Definition  
40h  
39h  
18h  
3Ah  
04h  
N
Compare  
N
N
N
Y
N
Y
Y
Y
Y
Y
N
Y
Y
Y
Y
Y
Y
Y
Y
N
Y
Y
N
Y
Y
N
N
N
Y
Y
Y
N
Y
Y
N
Copy  
Copy and Verify  
Format Unit [1]  
DPRY bit supported  
DCRT bit supported  
STPF bit supported  
IP bit supported  
DSP bit supported  
IMMED bit supported  
VS (vendor specific)  
Inquiry  
12h  
Date Code page (C1h)  
Device Behavior page (C3h)  
Firmware Numbers page (C0h)  
Implemented Operating Def page (81h)  
Jumper Settings page (C2h)  
Supported Vital Product Data page (00h)  
Unit Serial Number page (80h)  
Lock-unlock cache  
Log Select  
36h  
4Ch  
PCR bit  
DU bit  
DS bit  
TSD bit  
ETC bit  
TMC bit  
LP bit  
Protocol-specific Log Page for SAS (18h)  
Log Sense  
4Dh  
Application Client Log page (0Fh)  
Buffer Over-run/Under-run page (01h)  
Cache Statistics page (37h)  
Factory Log page (3Eh)  
Information Exceptions Log page (2Fh)  
48  
Savvio 15K.2 SAS Product Manual, Rev. E  
   
Table 7:  
Supported commands  
Command name  
Command code  
Supported  
Last n Deferred Errors or Asynchronous Events page (0Bh)  
Last n Error Events page (07h)  
Non-medium Error page (06h)  
Pages Supported list (00h)  
Read Error Counter page (03h)  
Read Reverse Error Counter page (04h)  
Self-test Results page (10h)  
Start-stop Cycle Counter page (0Eh)  
Temperature page (0Dh)  
N
N
Y
Y
Y
N
Y
N
Y
Verify Error Counter page (05h)  
Write error counter page (02h)  
Mode Select (same pages as Mode Sense 1Ah)  
Mode Select (10) (same pages as Mode Sense 1Ah)  
Mode Sense  
Y
Y
15h  
55h  
1Ah  
Y [2]  
Y
Y [2]  
Y
Caching Parameters page (08h)  
Control Mode page (0Ah)  
Y
Disconnect/Reconnect (02h)  
Error Recovery page (01h)  
Format page (03h)  
Y
Y
Y
Information Exceptions Control page (1Ch)  
Background Scan mode subpage (01h)  
Notch and Partition Page (0Ch)  
Protocol-Specific Port page (19h)  
Power Condition page (1Ah)  
Rigid Disc Drive Geometry page (04h)  
Unit Attention page (00h)  
Y
Y
N
Y
Y
Y
Y
Verify Error Recovery page (07h)  
Xor Control page (10h)  
Y
N
Y
Mode Sense (10) (same pages as Mode Sense 1Ah)  
Persistent Reserve In  
5Ah  
5Eh  
5Fh  
34h  
08h  
28h  
Y
Persistent Reserve Out  
Y
Prefetch  
N
Y
Read (6)  
Read (10)  
Y
DPO bit supported  
Y
FUA bit supported  
Y
Read (12)  
A8h  
N
N
N
Read (16)  
88h  
Read (32)  
7Fh/0009h  
Savvio 15K.2 SAS Product Manual, Rev. E  
49  
Table 7:  
Supported commands  
Command name  
Command code  
3Ch  
Supported  
Read Buffer (modes 0, 2, 3, Ah and Bh supported)  
Read Capacity (10)  
Read Capacity (16)  
Read Defect Data (10)  
Read Defect Data (12)  
Read Long  
Y
25h  
Y
N
Y
Y
Y
N
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
N
Y
Y
N
Y
N
N
N
Y
Y
Y
Y
Y
N
Y
Y
N
Y
Y
9Eh/10h  
37h  
B7h  
3Eh  
Read Long (16)  
9Eh/11h  
07h  
Reassign Blocks  
Receive Diagnostic Results  
Supported Diagnostics pages (00h)  
Translate page (40h)  
Release  
1Ch  
17h  
57h  
A0h  
03h  
Release (10)  
Report LUNs  
Request Sense  
Actual Retry Count bytes  
Extended Sense  
Field Pointer bytes  
Reserve  
16h  
56h  
3rd Party Reserve  
Extent Reservation  
Reserve (10)  
3rd Party Reserve  
Extent Reservation  
Rezero Unit  
01h  
31h  
30h  
32h  
0Bh  
2Bh  
1Dh  
Search Data Equal  
Search Data High  
Search Data Low  
Seek (6)  
Seek (10)  
Send Diagnostics  
Supported Diagnostics pages (00h)  
Translate page (40h)  
Set Limits  
33h  
1Bh  
35h  
91h  
00h  
2Fh  
Start Unit/Stop Unit (spindle ceases rotating)  
Synchronize Cache  
Synchronize Cache (16)  
Test Unit Ready  
Verify (10)  
50  
Savvio 15K.2 SAS Product Manual, Rev. E  
Table 7:  
Supported commands  
Command name  
Command code  
Supported  
BYTCHK bit  
Y
Verify (12)  
AFh  
N
N
N
Y
Y
Y
Y
N
N
N
Y
Y
N
N
N
Y
Verify (16)  
AFh  
Verify (32)  
7Fh/000Ah  
0Ah  
Write (6)  
Write (10)  
2Ah  
DPO bit  
FUA bit  
Write (12)  
AAh  
Write (16)  
8Ah  
Write (32)  
7Fh/000Bh  
2Eh  
Write and Verify (10)  
DPO bit  
Write and Verify (12)  
AEh  
Write and Verify (16)  
8Eh  
Write and Verify (32)  
7Fh/000Ch  
3Bh  
Write Buffer (modes 0, 2, supported)  
Write Buffer  
3Bh  
Firmware Download option (modes 5, 7, Ah and Bh) [3]  
Y
Y
N
Y
N
N
N
N
N
N
N
Write Long (10)  
Write Long (16)  
Write Same (10)  
PBdata  
3Fh  
9Fh/11h  
41h  
LBdata  
Write Same (16)  
Write Same (32)  
XDRead  
93h  
7Fh/000Dh  
52h  
XDWrite  
50h  
XPWrite  
51h  
[1] Savvio drives can format to 512, 520, 524, or 528 bytes per logical block.  
[2] Warning. Power loss during flash programming can result in firmware corruption. This usually makes the  
drive inoperable.  
[3] Reference Mode Sense command 1Ah for mode pages supported.  
[4] Y = Yes. Command is supported.  
N = No. Command is not supported.  
A = Support is available on special request.  
Savvio 15K.2 SAS Product Manual, Rev. E  
51  
   
12.3.1  
Inquiry data  
Table 8 lists the Inquiry command data that the drive should return to the initiator per the format given in the  
SAS Interface Manual.  
Table 8:  
Savvio inquiry data  
Data (hex)  
Bytes  
0-15  
00  
[53  
R#  
00  
00  
00  
00  
00  
54  
R#  
00  
00  
00  
43  
03** 12  
8B  
34  
S#  
00  
00  
00  
79  
53  
74  
00  
36  
S#  
00  
00  
00  
72  
65  
73  
PP  
38  
S#  
00  
00  
00  
69  
61  
20  
0A  
35  
S#  
00  
00  
00  
67  
67  
72  
53  
52  
S#  
00  
00  
00  
68  
61  
65  
45  
53  
S#  
00  
00  
00  
74  
74  
73  
41  
53  
S#  
00  
00  
00  
20  
65  
65  
47  
20  
S#  
00  
00  
00  
28  
20  
72  
41  
20  
00  
00  
00  
00  
63  
41  
76  
54  
20  
00  
00  
00  
00  
29  
6C  
65  
45  
20  
00  
00  
00  
00  
20  
6C  
64  
20  
20  
00  
00  
00  
00  
Vendor ID  
Product ID  
16-31  
32-47  
48-63  
64-79  
80-95  
96-111  
112-127  
128-143  
39  
R#  
00  
00  
00  
6F  
31  
R#  
00  
00  
00  
70  
20  
68  
32* *Copyright  
30* 30* 36*  
72 69 67  
20  
20  
notice  
*
Copyright year (changes with actual year).  
SCSI Revision support. See the appropriate SPC release documentation for definitions.  
**  
PP 10 = Inquiry data for an Inquiry command received on Port A.  
30 = Inquiry data for an Inquiry command received on Port B.  
R# Four ASCII digits representing the last four digits of the product firmware release number.  
S# Eight ASCII digits representing the eight digits of the product serial number.  
[ ]  
Bytes 16 through 26 reflect model of drive. The table above shows the hex values for Model ST9146852SS.  
Refer to the values below for the values of bytes 16 through 26 of your particular model:  
ST9146752SS  
ST9146652SS  
ST973452SS  
ST973352SS  
ST973252SS  
53 54 39 31 34 36 37 35 32 53 53  
53 54 39 31 34 36 36 35 32 53 53  
53 54 39 37 33 34 35 32 53 53  
53 54 39 37 33 33 35 32 53 53  
53 54 39 37 33 32 35 32 53 53  
12.3.2  
Mode Sense data  
The Mode Sense command provides a way for the drive to report its operating parameters to the initiator. The  
drive maintains four sets of mode parameters:  
1. Default values  
Default values are hard-coded in the drive firmware stored in flash E-PROM (nonvolatile memory) on the  
drive’s PCB. These default values can be changed only by downloading a complete set of new firmware  
into the flash E-PROM. An initiator can request and receive from the drive a list of default values and use  
those in a Mode Select command to set up new current and saved values, where the values are change-  
able.  
2. Saved values  
Saved values are stored on the drive’s media using a Mode Select command. Only parameter values that  
are allowed to be changed can be changed by this method. Parameters in the saved values list that are not  
changeable by the Mode Select command get their values from default values storage.  
52  
Savvio 15K.2 SAS Product Manual, Rev. E  
         
When power is applied to the drive, it takes saved values from the media and stores them as current val-  
ues in volatile memory. It is not possible to change the current values (or the saved values) with a Mode  
Select command before the drive achieves operating speed and is “ready.” An attempt to do so results in a  
“Check Condition” status.  
On drives requiring unique saved values, the required unique saved values are stored into the saved val-  
ues storage location on the media prior to shipping the drive. Some drives may have unique firmware with  
unique default values also.  
On standard OEM drives, the saved values are taken from the default values list and stored into the saved  
values storage location on the media prior to shipping.  
3. Current values  
Current values are volatile values being used by the drive to control its operation. A Mode Select command  
can be used to change the values identified as changeable values. Originally, current values are installed  
from saved or default values after a power on reset, hard reset, or Bus Device Reset message.  
4. Changeable values  
Changeable values form a bit mask, stored in nonvolatile memory, that dictates which of the current values  
and saved values can be changed by a Mode Select command. A one (1) indicates the value can be  
changed. A zero (0) indicates the value is not changeable. For example, in Table 9, refer to Mode page 81,  
in the row entitled “CHG.” These are hex numbers representing the changeable values for Mode page 81.  
Note in columns 5 and 6 (bytes 04 and 05), there is 00h which indicates that in bytes 04 and 05 none of the  
bits are changeable. Note also that bytes 06, 07, 09, 10, and 11 are not changeable, because those fields  
are all zeros. In byte 02, hex value FF equates to the binary pattern 11111111. If there is a zero in any bit  
position in the field, it means that bit is not changeable. Since all of the bits in byte 02 are ones, all of these  
bits are changeable.  
The changeable values list can only be changed by downloading new firmware into the flash E-PROM.  
Note. Because there are often several different versions of drive control firmware in the total population of  
drives in the field, the Mode Sense values given in the following tables may not exactly match those  
of some drives.  
The following tables list the values of the data bytes returned by the drive in response to the Mode Sense com-  
mand pages for SCSI implementation (see the SAS Interface Manual).  
DEF = Default value. Standard OEM drives are shipped configured this way.  
CHG = Changeable bits; indicates if default value is changeable.  
Savvio 15K.2 SAS Product Manual, Rev. E  
53  
Table 9:  
Mode Sense data default and changeable values for 146GB drives  
MODE DATA HEADER:  
00 00 05 12 8B 00 30 02  
MODE PAGES:  
DEF 81 0A C0 0B FF 00 00 00 05 00 FF FF  
CHG 81 0A FF FF 00 00 00 00 FF 00 FF FF  
DEF 82 0E 00 00 00 00 00 00 00 00 01 3A 00 00 00 00  
CHG 82 0E 00 00 00 00 00 00 00 00 FF FF 00 00 00 00  
DEF 83 16 BB D0 00 00 00 00 03 80 04 C4 02 00 00 01 00 E0 00 4C 40 00 00 00  
CHG 83 16 00 00 00 00 00 00 FF FF 00 00 00 00 00 00 00 00 00 00 00 00 00 00  
DEF 84 16 00 EC BD 04 00 00 00 00 00 00 00 00 00 00 00 00 00 00 3A A7 00 00  
CHG 84 16 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00  
DEF 87 0A 00 0B FF 00 00 00 00 00 FF FF  
CHG 87 0A 0F FF 00 00 00 00 00 00 FF FF  
DEF 88 12 14 00 FF FF 00 00 FF FF FF FF 80 20 00 00 00 00 00 00  
CHG 88 12 A5 00 00 00 FF FF FF FF 00 00 20 00 00 00 00 00 00 00  
DEF 8A 0A 02 00 00 00 00 00 00 00 05 57  
CHG 8A 0A 03 F0 00 00 00 00 00 00 00 00  
DEF 18 06 06 00 00 00 00 00  
CHG 18 06 00 00 00 00 00 00  
DEF 99 06 06 00 07 D0 00 00  
CHG 99 06 10 00 FF FF FF FF  
DEF 9A 0A 00 02 00 00 00 0A 00 00 8C A0  
CHG 9A 0A 00 03 FF FF FF FF FF FF FF FF  
DEF 9C 0A 10 00 00 00 00 00 00 00 00 01  
CHG 9C 0A 9D 0F FF FF FF FF FF FF FF FF  
DEF 80 06 00 80 0F 00 00 00  
CHG 80 06 B7 C0 8F 00 00 00  
54  
Savvio 15K.2 SAS Product Manual, Rev. E  
   
Table 10:  
Mode Sense data default and changeable values for 73GB drives  
MODE DATA HEADER:  
00 00 05 12 8B 00 10 02  
MODE PAGES:  
DEF 81 0A C0 0B FF 00 00 00 05 00 FF FF  
CHG 81 0A FF FF 00 00 00 00 FF 00 FF FF  
DEF 82 0E 00 00 00 00 00 00 00 00 01 3A 00 00 00 00  
CHG 82 0E 00 00 00 00 00 00 00 00 FF FF 00 00 00 00  
DEF 83 16 BB D0 00 00 00 00 03 80 04 C4 02 00 00 01 00 E0 00 4C 40 00 00 00  
CHG 83 16 00 00 00 00 00 00 FF FF 00 00 00 00 00 00 00 00 00 00 00 00 00 00  
DEF 84 16 00 EC BD 02 00 00 00 00 00 00 00 00 00 00 00 00 00 00 3A A7 00 00  
CHG 84 16 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00  
DEF 87 0A 00 0B FF 00 00 00 00 00 FF FF  
CHG 87 0A 0F FF 00 00 00 00 00 00 FF FF  
DEF 88 12 14 00 FF FF 00 00 FF FF FF FF 80 20 00 00 00 00 00 00  
CHG 88 12 A5 00 00 00 FF FF FF FF 00 00 20 00 00 00 00 00 00 00  
DEF 8A 0A 02 00 00 00 00 00 00 00 02 D1  
CHG 8A 0A 03 F0 00 00 00 00 00 00 00 00  
DEF 18 06 06 00 00 00 00 00  
CHG 18 06 00 00 00 00 00 00  
DEF 99 06 06 00 07 D0 00 00  
CHG 99 06 10 00 FF FF FF FF  
DEF 9A 0A 00 02 00 00 00 0A 00 00 8C A0  
CHG 9A 0A 00 03 FF FF FF FF FF FF FF FF  
DEF 9C 0A 10 00 00 00 00 00 00 00 00 01  
CHG 9C 0A 9D 0F FF FF FF FF FF FF FF FF  
DEF 80 06 00 80 0F 00 00 00  
CHG 80 06 B7 C0 8F 00 00 00  
Savvio 15K.2 SAS Product Manual, Rev. E  
55  
12.4  
Miscellaneous operating features and conditions  
Table 11 lists various features and conditions. A “Y” in the support column indicates the feature or condition is  
supported. An “N” in the support column indicates the feature or condition is not supported.  
Table 11:  
Miscellaneous features  
Supported  
Feature or condition  
N
N
N
Y
N
Y
Y
Y
Y
N
Y
Automatic contingent allegiance  
Asynchronous event notification  
Synchronized (locked) spindle operation  
Segmented caching  
Zero latency read  
Queue tagging (up to 128 queue tags supported)  
Deferred error handling  
Parameter rounding (controlled by Round bit in Mode Select page 0)  
Reporting actual retry count in Extended Sense bytes 15, 16, and 17  
Adaptive caching  
SMP = 1 in Mode Select command needed to save RPL and rotational offset bytes  
Table 12:  
Miscellaneous status  
Supported  
Status  
Y
Y
Y
Y
Y
Y
Y
Y
N
N
Good  
Check condition  
Condition met/good  
Busy  
Intermediate/good  
Intermediate/condition met/good  
Reservation conflict  
Task set full  
ACA active  
ACA active, faulted initiator  
56  
Savvio 15K.2 SAS Product Manual, Rev. E  
                                             
12.4.1  
SAS physical interface  
Figure 13 shows the location of the SAS device connector J1. Figures 14 and 15 provide the dimensions of the  
SAS connector.  
Details of the physical, electrical, and logical characteristics are provided within this section. The operational  
aspects of Seagate’s SAS drives are provided in the SAS Interface Manual.  
Figure 13. Physical interface  
Savvio 15K.2 SAS Product Manual, Rev. E  
57  
       
0.80 (6X)  
5.92  
7.62  
4.65  
0.52 0.08 x 45  
2.00 (3X)  
0.45 0.03 (7X)  
0.10 M E  
5.08  
42.73 REF.  
41.13 0.15  
0.20B  
0.30 0.05 (2X)  
C
A
B
1.10  
4.00 0.08  
0.15D  
C OF DATUM D  
L
R0.30 0.08 (4X)  
A
0.30 0.05 (4X)  
B
C
SEE Detail1  
B
33.43 0.05  
15.875  
15.875  
1.27 (14X)  
1.27 (6X)  
0.84 0.05 (22X)  
5.08  
0.15B  
4.90 0.08  
0.35MIN  
P15  
S1  
P1  
S7  
C OF DATUM B  
L
Figure 14. SAS device plug dimensions  
58  
Savvio 15K.2 SAS Product Manual, Rev. E  
 
Detail A  
6.10  
S14  
S8  
0.30 0.05 x 45 (5X)  
2.25 0.05  
0.40 0.05 X 45 (3X)  
4.85 0.05  
0.10B  
CORING ALLOWED  
IN THIS AREA.  
E
4.40 0.15  
R0.30 0.08  
45  
C
SEE Detail 2  
1.95 0.08  
A
0.35 0.05  
SECTION C - C  
3.90 0.15  
SECTION A - A  
CONTACT SURFACE FLUSH  
TO DATUM A 0.03  
0.08 0.05  
65  
1.90 0.08  
1.23 0.05  
0.08 0.05  
30  
Detail 2  
2.40 0.08  
0.10 A  
SECTION B - B  
D
Figure 15. SAS device plug dimensions (detail)  
Savvio 15K.2 SAS Product Manual, Rev. E  
59  
 
12.4.2  
Physical characteristics  
This section defines physical interface connector.  
12.4.3  
Connector requirements  
Contact your preferred connector manufacturer for mating part information. Part numbers for SAS connectors  
will be provided in a future revision of this publication when production parts are available from major connec-  
tor manufacturers.  
The SAS device connector is illustrated in Figures 14 and 15.  
12.4.4  
Electrical description  
SAS drives use the device connector for:  
• DC power  
• SAS interface  
• Activity LED  
This connector is designed to either plug directly into a backpanel or accept cables.  
12.4.5  
Pin descriptions  
This section provides a pin-out of the SAS device and a description of the functions provided by the pins.  
60  
Savvio 15K.2 SAS Product Manual, Rev. E  
                         
Table 13:  
SAS pin descriptions  
Pin  
S1  
Signal name Signal type  
Pin  
Signal name  
Signal type  
Port A Ground  
+Port A_in  
P1* NC (reserved 3.3Volts)  
P2* NC (reserved 3.3Volts)  
S2*  
S3*  
S4  
Diff. input pair  
Diff output pair  
-Port A_in  
P3  
P4  
P5  
P6  
P7  
NC (reserved 3.3Volts)  
Ground  
Port A Ground  
-Port A_out  
+Port A_out  
Port A Ground  
Port B Ground  
+Port B_in  
S5*  
S6*  
S7  
Ground  
Ground  
5 Volts charge  
S8  
P8* 5 Volts  
P9* 5 Volts  
P10 Ground  
S9*  
Diff. input pair  
S10 -Port B_in  
*
S11 Port A Ground  
P11 Ready LED  
*
Open collector out  
S12 -Port B_out  
*
Diff output pair  
P12 Ground  
S13 +Port B_out  
*
P13 12 Volts charge  
S14 Port B Ground  
P14 12 Volts  
*
P15 12 Volts  
*
* - Short pin to support hot plugging  
NC - No connection in the drive.  
12.4.6  
SAS transmitters and receivers  
A typical SAS differential copper transmitter and receiver pair is shown in Figure 16. The receiver is AC cou-  
pling to eliminate ground shift noise.  
.01  
TX  
TY  
RX  
Differential  
Transfer Medium  
Transmitter  
100  
Receiver  
100  
RY  
.01  
Figure 16. SAS transmitters and receivers  
Savvio 15K.2 SAS Product Manual, Rev. E  
61  
             
12.4.7  
Power  
The drive receives power (+5 volts and +12 volts) through the SAS device connector.  
Three +12 volt pins provide power to the drive, 2 short and 1 long. The current return for the +12 volt power  
supply is through the common ground pins. The supply current and return current must be distributed as  
evenly as possible among the pins.  
Three +5 volt pins provide power to the drive, 2 short and 1 long. The current return for the +5 volt power sup-  
ply is through the common ground pins. The supply current and return current must be distributed as evenly as  
possible among the pins.  
Current to the drive through the long power pins may be limited by the system to reduce inrush current to the  
drive during hot plugging.  
12.5  
Signal characteristics  
This section describes the electrical signal characteristics of the drive’s input and output signals. See Table 13  
for signal type and signal name information.  
12.5.1  
Ready LED Out  
The Ready LED Out signal is driven by the drive as indicated in Table 14.  
Table 14:  
Ready LED Out conditions  
Normal command activity  
LED status  
0
1
Ready LED Meaning bit mode page 19h  
Spun down and no activity  
Off  
On  
On  
Off  
Off  
On  
Off  
On  
Spun down and activity (command executing)  
Spun up and no activity  
Spun up and activity (command executing)  
Spinning up or down  
Blinks steadily  
(50% on and 50% off, 0.5 seconds on and off for 0.5 seconds)  
Format in progress, each cylinder change  
Toggles on/off  
The Ready LED Out signal is designed to pull down the cathode of an LED. The anode is attached to the  
proper +3.3 volt supply through an appropriate current limiting resistor. The LED and the current limiting resis-  
tor are external to the drive. See Table 15 for the output characteristics of the LED drive signals.  
Table 15:  
LED drive signal  
State  
Test condition  
0 V VOH 3.6 V  
= 15 mA  
Output voltage  
LED off, high  
LED on, low  
-100 µA < I < 100 µA  
OH  
I
0 VOL 0.225 V  
OL  
12.5.2  
Differential signals  
The drive SAS differential signals comply with the intra-enclosure (internal connector) requirements of the SAS  
standard.  
62  
Savvio 15K.2 SAS Product Manual, Rev. E  
                       
Table 16 defines the general interface characteristics.  
Table 16: General interface characteristics  
Characteristic  
Units  
Mbaud  
ps  
1.5 Gbps  
1,500  
666.6  
100  
3.0 Gbps  
3,000  
333.3  
100  
6.0 Gbps  
6,000  
166.6  
100  
Bit rate (nominal)  
Unit interval (UI)(nominal)  
Impedance (nominal, differential )  
Transmitter transients, maximum  
Receiver transients, maximum  
ohm  
V
1.2  
1.2  
1.2  
V
1.2  
1.2  
1.2  
12.6  
SAS-2 Specification compliance  
Seagate SAS-2 drives are entirely compatible with the latest SAS-2 Specification (T10/1760-D) Revision 16.  
The most important characteristic of the SAS-2 drive at 6 Gbps is that the receiver is capable of adapting the  
equalizer to optimize the receive margins. The SAS-2 drive has two types of equalizers:  
1. A Decision Feedback Equalizer (DFE) which utilizes the standard SAS-2 training pattern transmitted dur-  
ing the SNW-3 training gap. The DFE circuit can derive an optimal equalization characteristic to compen-  
sate for many of the receive losses in the system.  
2. A Feed Forward Equalizer (FFE) optimized to provide balanced receive margins over a range of channels  
bounded by the best and worst case channels as defined by the relevant ANSI standard.  
12.7  
Additional information  
Please contact your Seagate representative for SAS electrical details, if required.  
For more information about the Phy, Link, Transport, and Applications layers of the SAS interface, refer to the  
Seagate SAS Interface Manual, part number 100293071.  
For more information about the SCSI commands used by Seagate SAS drives, refer to the Seagate SCSI  
Commands Reference Manual, part number 100293068.  
Savvio 15K.2 SAS Product Manual, Rev. E  
63  
                   
64  
Savvio 15K.2 SAS Product Manual, Rev. E  
cache segments 12  
caching write data 13  
Canadian Department of Communications 3  
capacity  
unformatted 10  
case temperature 29  
CBC 36  
Index  
Numerics  
12 volt  
pins 62  
5 volt pins 62  
6 Gbps 63  
CE Marking 4  
check condition status 56  
Cipher Block Chaining 36  
class B limit 3  
A
clear ACA function 46  
clear task set function 46  
commands supported 48  
condensation 29  
condition met/good status 56  
connector  
abort task set function 46  
AC coupling 61  
AC power requirements 21  
ACA active status 56  
ACA active, faulted initiator status 56  
acoustics 33  
illustrated 60  
requirements 60  
active LED Out signal 62  
actuator 8  
continuous vibration 32  
cooling 44  
CRC  
assembly design 6  
adaptive caching 56  
Admin SP 36  
error 15  
AES-128 data encryption 36  
air cleanliness 32  
Cryptographic erase 38  
Current profiles 25  
customer service 20  
air flow 29, 44  
illustrated 44  
air inlet 44  
altitude 30  
ambient 29  
ambient temperature 29, 44  
ANSI documents  
D
DAR 41  
Data Bands 37  
data bands 36  
SCSI 5  
data block size  
Serial Attached SCSI 5  
asynchronous event notification 56  
audible noise 3  
auto write and read reallocation  
programmable 7  
automatic contingent allegiance 56  
average idle current 22, 23  
average rotational latency 10  
modifing the 8  
Data encryption 36  
Data Encryption Key 36  
data heads  
read/write 10  
data rate  
internal 10  
data transfer rate 11  
DC power 60  
requirements 21  
Decision Feedback Equalizer 63  
decrypt 36  
default MSID password 37  
defect and error management 39  
defects 39  
B
Background Media Scan 41  
backpanel 60  
Band 0 37  
BandMasterX 37  
BMS 41  
Deferred Auto-Reallocation 41  
deferred error handling 56  
DEK 36  
buffer  
data 7  
space 12  
description 6  
busy status 56  
DFE 63  
dimensions 34  
disc rotation speed 10  
drive 32  
C
cache operation 12  
Savvio 15K.2 SAS Product Manual, Rev. E  
65  
drive characteristics 10  
Drive Locking 37  
drive mounting 34, 45  
drive select 60  
H
HDA 44, 45  
head and disc assembly (HDA) 6  
heads  
dual port support 47  
read/write data 10  
heat removal 44  
heat source 44  
E
electrical  
description of connector 60  
signal characteristics 62  
specifications 21  
host equipment 45  
hot plugging the drive 15  
humidity 29  
electromagnetic compatibility 3  
Electromagnetic Compatibility (EMC) 4  
Electromagnetic Compatibility control Regulation 4  
electromagnetic susceptibility 33  
EMI requirements 3  
encryption engine 36  
encryption key 37  
humidity limits 29  
I
Idle Read After Write 42  
inquiry data 52  
installation 43  
guide 5  
interface  
environment 44  
environmental  
commands supported 48  
error rate 14  
errors 15  
illustrated 57  
physical 57  
limits 29  
requirements 14  
environmental control 32  
EraseMaster 37  
error  
requirements 46  
management 39  
intermediate/condition met/good status 56  
intermediate/good status 56  
internal data rate 10  
internal defects/errors 39  
internal drive characteristics 10  
IRAW 42  
rates 14  
errors 39  
F
FCC rules and regulations 3  
features 7  
interface 46  
J
Federal Information Processing Standard 35  
feed forward equalizer 63  
FFE 63  
jumpers 43  
K
FIPS 35  
firmware 7  
KCC 4  
corruption 51  
Korean Communications Commission 4  
firmware download port 37  
flawed sector reallocation 7  
Format command execution time 11  
function  
L
latency  
average rotational 10  
Locking SP 36, 37  
LockOnReset 37  
logical block address 12  
logical block reallocation scheme 7  
logical block size 7, 11  
logical segments 12  
complete, code 00 46  
not supported, code 05 46  
reject, code 04 46  
G
Global Data Band 37  
Good status 56  
gradient 29  
ground shift noise 61  
grounding 45  
M
maintenance 14  
Makers Secure ID 36  
66  
Savvio 15K.2 SAS Product Manual, Rev. E  
maximum delayed motor start 22, 23  
maximum start current 22, 23  
media description 7  
Media Pre-Scan 41  
miscellaneous feature support  
Adaptive caching 56  
P
package size 31  
package test specification 5  
packaged 31  
parameter rounding 56  
password 36, 37  
passwords 37  
Asynchronous event notification 56  
Automatic contingent allegiance 56  
Deferred error handling 56  
Parameter rounding 56  
Queue tagging 56  
Reporting actual retry count 56  
Segmented caching 56  
SMP = 1 in Mode Select command 56  
Synchronized (locked) spindle operation 56  
Zero latency read 56  
PCBA 45  
peak bits per inch 10  
peak operating current 22, 23  
peak-to-peak measurements 24  
performance characteristics  
detailed 10  
general 11  
performance degradation 30  
performance highlights 8  
physical damage 32  
physical interface 57  
physical specifications 21  
pin descriptions 60  
power 62  
miscellaneous status support  
ACA active 56  
ACA active, faulted initiator 56  
Busy 56  
Check condition 56  
Condition met/good 56  
Good 56  
Intermediate/condition met/good 56  
Intermediate/good 56  
Reservation conflict 56  
Task set full 56  
dissipation 27  
requirements, AC 21  
requirements, DC 21  
sequencing 24  
power distribution 3  
PowerCycle 37  
prefetch/multi-segmented cache control 12  
preventive maintenance 14  
protection of data at rest 36  
miscorrected media data 14  
Mode sense  
data, table 52, 54  
mounting 45  
Q
holes 45  
orientations 43  
queue tagging 56  
mounting configuration 34  
MSID 36, 37  
MTBF 14, 15, 29  
R
radio interference regulations 3  
Random number generator 37  
RCD bit 12  
read error rates 14, 39  
read/write data heads 10  
receivers 61  
N
National Institute of Standards and Technology 35  
NIST 35  
noise  
audible 3  
recommended mounting 31  
Recoverable Errors 14  
recovered media data 14  
reference  
noise immunity 24  
non-operating 29, 30, 32  
temperature 29  
non-operating vibration 32  
documents 5  
relative humidity 29  
reliability 8  
O
specifications 14  
office environment 32  
operating 29, 30, 32  
option selection 60  
orientation 30  
reliability and service 15  
repair and return information 20  
reporting actual retry count 56  
reservation conflict status 56  
resonance 30  
out-of-plane distortion 45  
Savvio 15K.2 SAS Product Manual, Rev. E  
67  
return information 20  
RNG 37  
system chassis 45  
rotation speed 10  
T
task management functions 46  
Abort task set 46  
Clear ACA 46  
S
safety 3  
SAS  
Clear task set 46  
terminate task 46  
task management response codes 46  
Function complete 00 46  
Function not supported 05 46  
Function reject 04 46  
task set full status 56  
TCG 36  
interface 60  
physical interface 57  
task management functions 46  
SAS documents 5  
SAS Interface Manual 3, 5  
SAS-2 Specification 63  
SCSI interface  
commands supported 48  
Secure ID 36  
security partitions 36  
Security Protocol In 36  
Security Protocol Out 36  
seek error  
technical support services 1  
temperature 29, 44  
ambient 29  
case 29  
gradient 29  
limits 29  
defined 15  
rate 14  
non-operating 29  
regulation 3  
seek performance characteristics 10  
seek time  
See also cooling  
terminate task function 46  
terminators 43  
tracks per inch 10  
tracks per surface 10  
transmitters 61  
average typical 10  
full stroke typical 10  
single track typical 10  
segmented caching 56  
self-encrypting drives 36  
transporting the drive 20  
Self-Monitoring Analysis and Reporting Technology Trusted Computing Group 36  
Serial Attached SCSI (SAS) Interface Manual 2  
shielding 3  
U
unformatted 8  
shipping 20  
Unrecoverable Errors 14  
shipping container 29  
unrecovered media data 14  
shock 30  
and vibration 30  
shock mount 45  
V
SID 36  
signal  
vibration 30, 32  
characteristics 62  
single-unit shipping pack kit 9  
SMART 8, 16  
W
warranty 20  
SMP = 1 in Mode Select command 56  
SNW-3 training gap 63  
Specification 63  
Z
zero latency read 56  
spindle brake 7  
zone bit recording (ZBR) 7  
standards 3  
start/stop time 11  
support services 1  
surface stiffness  
allowable for non-flat surface 45  
switches 43  
synchronized spindle  
operation 56  
68  
Savvio 15K.2 SAS Product Manual, Rev. E  
Seagate Technology LLC  
920 Disc Drive, Scotts Valley, California 95066-4544, USA  
Publication Number: 100516230, Rev. E  

Toshiba Scorpio WD2500BPVT User Manual
Toastmaster ME8TPW User Manual
Sun Microsystems StorageTek 96257 User Manual
Simplicity 1692353 User Manual
Simplicity 1692210 User Manual
Seagate ST315005EXA101 RK User Manual
Seagate MEDALIST ST33220A User Manual
Samsung TS H292A User Manual
Samsung SPINPOINT MP2 HM201JJ User Manual
Samsung SCH 100S User Manual