I N S T A L L A T I O N
RK5000PS-3U/RK5000-3U
Rack Mount Chassis
For Fiber Optic Modules
C1972M-A (10/06)
Contents
Important Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Regulatory Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Front View (RK5000PS-3U) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Back View (RK5000-3U) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Package Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Installing a Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Installing a Blank Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Replacing an Internal Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
C1972M-A (10/06)
3
List of Illustrations
9
RK5000-3U Back View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Internal Power Supply Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
4
C1972M-A (10/06)
Important Safety Instructions
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with dry cloth.
7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A
grounding plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided
plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet.
10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the points where they exit from
the apparatus.
11. Only use attachments/accessories specified by the manufacturer.
12. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use
caution when moving the cart/apparatus combination to avoid injury from tip-over.
13. Unplug this apparatus during lightning storms or when unused for long periods of time.
14. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-
supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or
moisture, does not operate normally, or has been dropped.
15. Apparatus shall not be exposed to dripping or splashing and that no objects filled with liquids, such as vases shall be placed on the
apparatus.
16. WARNING: To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture.
17. Installation should be done only by qualified personnel and conform to all local codes.
18. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6, or 6P enclosure, it is designed for indoor use only and it must not
be installed where exposed to rain and moisture.
19. Use only installation methods and materials capable of supporting four times the maximum specified load.
20. CAUTION: These servicing instructions are for use by qualified service personnel only. To reduce the risk of electric shock do not perform
any servicing other that contained in the operating instructions unless you are qualified to do so.
21. Only use replacement parts recommended by Pelco.
The product and/or manual may bear the following marks:.
CAUTION:
WARNING: This symbol indicates that dangerous voltage constituting a risk of electric
shock is present within this unit
RISK OF ELECTRIC SHOCK.
DO NOT OPEN.
This symbol indicates that there are important operating and maintenance instructions in
the literature accompanying this unit.
C1972M-A (10/06)
5
Regulatory Notices
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
RADIO AND TELEVISION INTERFERENCE
This equipment has been tested and found to comply with the limits of a Class A digital device, pursuant to Part 15 of the FCC rules. These limits
are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual,
may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference
in which case the user will be required to correct the interference at his own expense.
Changes and Modifications not expressly approved by the manufacturer or registrant of this equipment can void your authority to operate this
equipment under Federal Communications Commission’s rules.
In order to maintain compliance with FCC regulations shielded cables must be used with this equipment. Operation with non-approved
equipment or unshielded cables is likely to result in interference to radio and television reception.
This Class A digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.
6
C1972M-A (10/06)
Description
The RK5000PS-3U rack mount chassis supports fiber optic modules. The chassis has 12 slots and an internal double-width power supply. You can
insert up to 12 single-width modules or a combination of single-width and double-width modules into the slots. For redundancy, you can use the
optional external power supply (EPS5000-120). It provides redundant power for up to two fully populated RK5000PS-3U chassis. You can mount
the chassis, which is 3 rack units (RU) high, into an EIA-standard, 19-inch rack.
The RK5000-3U chassis has 14 slots and requires an external power supply. You can insert up to 14 single-width modules or a combination of
single-width and double-width modules into the slots. You can mount the chassis, which is 3 rack units (RU) high, into an EIA-standard, 19-inch
rack. You can use the optional EPS5000-120 external power supply, which consists of dual 120 watt, hot swappable power supplies, to power up
to two fully populated RK5000-3U chassis. The EPS5000-120 is 1 RU high and rack mountable.
You can fill the empty module slots on either chassis with single-width blank modules (RK5001B-3U) and double-width blank modules
(RK50002B-3U).
WARNING: The internal double-width power supply must remain in the slots in which it is shipped. Do not relocate to the other slots.
MODELS
RK5000PS-3U
RK5000-3U
Rack mountable chassis with power supply, 3 RU
Rack mountable chassis, 3 RU; external power supply required
C1972M-A (10/06)
7
FRONT VIEW (RK5000PS-3U)
ᕡ
ᕢ
ᕣ
ᕤ
ᕥ
ᕦ
Rack Ears (2)
Power Supply
Module Slots (12)
Alarm from Module LED
Power Fail LED
Pelco Badge
ᕡ
ᕢ
ᕦ
ᕤ
ᕥ
ᕣ
Figure 1. RK5000PS-3U Front View
BACK VIEW (RK5000PS-3U)
ᕡ
ᕢ
ᕣ
ᕤ
ᕥ
Thumbscrews for Fastening Modules (12)
External Connector for Redundant Power Supply
Relay Output Connector with Screw Terminal
Power Button
Power Cord Connector
ᕢ
ᕣᕤᕥ
ᕡ
Figure 2. RK5000PS-3U Back View
8
C1972M-A (10/06)
Installation
PACKAGE CONTENTS
RK5000PS-3U
1 Rack mount chassis
4 Screws and washers for rack mounting
RK5000-3U
1 Rack mount chassis
4 Screws and washers for rack mounting
MOUNTING A CHASSIS
WARNING: To ensure adequate ventilation, 1 RU of space is required above and below the RK5000PS-3U.
The procedure for mounting an RK5000PS-3U and an RK5000-3U into a rack is exactly the same. To mount a chassis, follow these steps and refer
1. Insert the chassis into the rack.
2. Secure the chassis with the supplied screws and washers.
Figure 5. Mounting an RK5000PS-3U/RK5000-3U into a Rack
10
C1972M-A (10/06)
INSTALLING A MODULE
You can install single-width or double-width modules into the empty slots on the RK5000PS-3U chassis and RK5000-3U chassis. To install a
module, follow these steps and refer to Figure 6.
1. Insert the module into an empty slot of the chassis.
2. Secure the module by tightening the thumbscrew on the back of the chassis.
Figure 6. Module Installation
INSTALLING A BLANK MODULE
You can use single-width or double-width blank modules to fill the empty module slots on the chassis. To attach a blank module, follow these
1. Insert the blank module into the empty slot on the chassis.
2. Secure the blank module by tightening the thumbscrew on the back of the chassis.
Figure 7. Blank Module Installation
C1972M-A (10/06)
11
Service
REMOVING THE POWER BUS
You must remove the power bus from the RK5000PS-3U if you want to use the power supplies that are provided with the Fiber modules.
WARNING: Using the power supplies that are provided with the Fiber modules with the power bus on the RK5000PS-3U can cause
damage to the unit.
1. Turn off the power supply.
2. Remove the power supply.
3. Unscrew the five Phillips flat head screws.
Figure 8. Power Bus Removal
12
C1972M-A (10/06)
REPLACING AN INTERNAL POWER SUPPLY
You can easily replace the internal power supply in the RK5000PS-3U in case of failure. The front of the power supply has two LEDs. The top LED
turns red when there is an alarm condition from one of the modules. The bottom LED turns red when the power supply fails. To replace an
internal power supply, follow these steps and refer to Figure 9.
1. Unplug the power cord.
2. Unscrew the two thumbscrews on the back of the chassis that hold the power supply.
3. Remove the power supply.
4. Insert the new power supply.
5. Secure the power supply by tightening the two thumbscrews on the back of the chassis.
6. Plug in the power cord.
7. Turn on the power supply.
Figure 9. Internal Power Supply Replacement
C1972M-A (10/06)
13
Specifications
RK5000PS-3U
ELECTRICAL
Input Voltage
100-240 VAC
Input Current
1.0 A
Output Voltage
Output Current
Fuse Rating
12 VDC
10 A
1.6 A
Redundant Capability
Yes with optional EPS5000-120 power supply
MECHANICAL
Number of Slots
Module Orientation
Rack Units
12 for modules and 2 for power supply
Vertical
3
Construction
Finish
Aluminum
Black
GENERAL
Operating Temperature
Operating Humidity
Storage Humidity
Dimensions
32° to 122°F (0° to 50°C)
80% maximum relative humidity, noncondensing
95% maximum relative humidity, noncondensing
5.22” H x 18.99” W x 8.85” D (13.26 x 48.23 x 22.48 cm)
Fits 19-inch, EIA-standard rack
Mounting
Unit Weight
8.01 lb (3.63 kg), with power supply
25.53 lb (11.58 kg), fully populated
RK5000-3U
MECHANICAL
Number of Slots
Module Orientation
Rack Units
14 for modules
Vertical
3
Construction
Finish
Aluminum
Black
GENERAL
Dimensions
Mounting
5.22” H x 18.99” W x 8.85” D (13.26 x 48.23 x 22.48 cm)
Fits 19-inch, EIA-standard rack
Unit Weight
5.19 lb (2.35 kg), chassis only
25.63 lb (11.63 kg), fully populated
14
C1972M-A (10/06)
PRODUCT WARRANTY AND RETURN INFORMATION
WARRANTY
The above warranty provides the Dealer with specific legal rights. The Dealer may also have
additional rights, which are subject to variation from state to state.
Pelco will repair or replace, without charge, any merchandise proved defective in material or
workmanship for a period of one year after the date of shipment.
Exceptions to this warranty are as noted below:
If a warranty repair is required, the Dealer must contact Pelco at (800)þ289-9100 or
(559) 292-1981 to obtain a Repair Authorization number (RA), and provide the following
information:
•
Five years on FR/FT/FS Series fiber optic products and TW3000 Series unshielded twisted
pair transmission products.
1. Model and serial number
•
•
Three years on Genex® Series products (multiplexers, server, and keyboard).
Three years on Camclosure® and fixed camera models, except the CC3701H-2,
CC3701H-2X, CC3751H-2, CC3651H-2X, MC3651H-2, and MC3651H-2X camera models,
which have a five-year warranty.
2. Date of shipment, P.O. number, Sales Order number, or Pelco invoice number
3. Details of the defect or problem
•
•
•
Three years on PMCL200/300/400 Series LCD monitors.
If there is a dispute regarding the warranty of a product which does not fall under the
warranty conditions stated above, please include a written explanation with the product when
returned.
Two years on standard motorized or fixed focal length lenses.
Two years on Legacy®, CM6700/CM6800/CM9700 Series matrix, and DF5/DF8 Series
fixed dome products.
Two years on Spectra®, Esprit®, ExSite™, and PS20 scanners, including when used in
continuous motion applications.
Method of return shipment shall be the same or equal to the method by which the item was
received by Pelco.
•
•
•
Two years on Esprit and WW5700 Series window wiper (excluding wiper blades).
RETURNS
Two years (except lamp and color wheel) on Digital Light Processing (DLP®) displays.
The lamp and color wheel will be covered for a period of 90 days. The air filter is not
covered under warranty.
In order to expedite parts returned to the factory for repair or credit, please call the factory at
(800) 289-9100 or (559) 292-1981 to obtain an authorization number (CA number if returned for
credit, and RA number if returned for repair).
•
•
•
Eighteen months on DX Series digital video recorders, NVR300 Series network video
recorders, and Endura™ Series distributed network-based video products.
All merchandise returned for credit may be subject to a 20% restocking and refurbishing
charge.
One year (except video heads) on video cassette recorders (VCRs). Video heads will be
covered for a period of six months.
Goods returned for repair or credit should be clearly identified with the assigned CA or RA
number and freight should be prepaid. Ship to the appropriate address below.
Six months on all pan and tilts, scanners or preset lenses used in continuous motion
applications (that is, preset scan, tour and auto scan modes).
If you are located within the continental U.S., Alaska, Hawaii or Puerto Rico, send goods to:
Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco
shipment. All goods requiring warranty repair shall be sent freight prepaid to Pelco, Clovis,
California. Repairs made necessary by reason of misuse, alteration, normal wear, or accident
are not covered under this warranty.
Service Department
Pelco
3500 Pelco Way
Clovis, CA 93612-5699
Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from
the specific use or application made of the Products. Pelco’s liability for any claim, whether
based on breach of contract, negligence, infringement of any rights of any party or product lia-
bility, relating to the Products shall not exceed the price paid by the Dealer to Pelco for such
Products. In no event will Pelco be liable for any special, incidental or consequential damages
(including loss of use, loss of profit and claims of third parties) however caused, whether by
the negligence of Pelco or otherwise.
If you are located outside the continental U.S., Alaska, Hawaii or Puerto Rico and are
instructed to return goods to the USA, you may do one of the following:
If the goods are to be sent by a COURIER SERVICE, send the goods to:
Pelco
3500 Pelco Way
Clovis, CA 93612-5699 USA
The materials used in the manufacture of this document and its components are compliant to the requirements of Directive 2002/95/EC.
This equipment contains electrical or electronic components that must be recycled properly to comply with Directive 2002/96/EC of the European Union
regarding the disposal of waste electrical and electronic equipment (WEEE). Contact your local dealer for procedures for recycling this equipment.
REVISION HISTORY
Manual #
C1972M
C1972M-A
Date
11/04
10/06
Comments
Original version.
Added Warning to Description section and Mounting a Chassis section. Revised electrical specifications.
Pelco, the Pelco logo, Spectra, Genex, Esprit, Camclosure, and Legacy are registered trademarks of Pelco.
© Copyright 2006, Pelco. All rights reserved.
Worldwide Headquarters
3500 Pelco Way
Clovis, California 93612 USA
USA & Canada
Tel: 800/289-9100
Fax: 800/289-9150
International
Tel: 1-559/292-1981
Fax: 1-559/348-1120
ISO9001
Australia Canada Finland France Italy Russia Singapore Spain Sweden The Netherlands United Arab Emirates United Kingdom United States
|
|
|
|
|
|
|
|
|
|
|
|
|