PRECAUTIONS
In case of problem
Protect from humidity and dust
Do not use the camera if smoke or a strange odour comes from the
unit, or if it seems not to function correctly. Disconnect the power
cord immediately, and consult your dealer (or a Sanyo Authorized
Service Centre).
To prevent damages to the camera, do not install it where there is
greasy smoke or steam, where the dampness may get too high, or
where there is a lot of dust.
Protect from high temperatures
Do not open or modify
Do not install close to stoves, or other heat generating devices, such
as spotlights, etc., or where it could be subject to direct sunlight, as
that could cause deformation, discoloration or other damages.
Do not open the cabinet, as it may be dangerous and cause damage
to the unit. For internal settings and repairs, consult your dealer (or a
Sanyo Authorized Service Centre).
Be careful when installing close to the ceiling, in a kitchen or boiler
room, as the temperature may raise to high levels.
Do not put objects inside the unit
Install where the temperature range will stay between –10˚C and 50˚C.
(no condensation)
Make sure that no metal objects or flammable substance get inside
the camera. If used with a foreign object inside, it could cause a fire,
short-circuits or damages.
Cleaning
If water or a liquid gets inside the camera, disconnect the power cord
immediately, and consult your dealer (or a Sanyo Authorized Service
Centre). Be careful to protect the camera from rain, sea water, etc.
• Dirt can be removed from the cabinet by wiping it with a soft
cloth. To remove stains, wipe with a soft cloth moistened with a
soft detergent solution and wrung dry, then wipe dry with dry soft
cloth.
Be careful when handling the unit
• Do not use benzine, thinner or other chemical product on the
cabinet, as that may cause deformation and paint peeling. Before
using a chemical cloth, make sure to read all accompanying
instructions. Make sure that no plastic or rubber material comes
in contact with the cabinet for a long period of time, as that may
cause damage or paint peeling.
To prevent damages, do not drop the camera or subject it to strong
shock or vibration.
Install away from electric or magnetic fields
If installed close to a TV, radio transmitter, magnet, electric motor,
transformer, audio speakers the magnetic field they generate will
distort the image.
2
English
PARTS NAMES
1 Video output connector (VIDEO OUT: BNC type)
Connect this connector to a device such as a VCR or monitor with a VIDEO IN connector.
2 External sync composite video signal input connector
3
2
1
(VS IN: BNC type)
Connect to this connector the synchronizing signal output from a synchronizing signal device or the composite
signal of a video distributor.
4
3 Power indicator (POWER)
Comes on when the power to the camera is on.
4 12 V DC input terminal (12 V DC, NC)
Connect DC connecting cord from the AC adaptor to the 12V DC input terminal on the camera.
Then, plug the AC adaptor into an AC outlet.
5 Camera setup section (under the cover)
5
These settings are for when using a 1/2 inch CS mount DC (without EE internal amplifier) type lens. However,
if due to installation conditions or environment the settings may need to be modified for best results (see
"SETTINGS").
6
To access the controls, loosen the cover fixing screw A, then remove the cover.
1
2
3
6 Lens iris output connector (LENS)
A
This 4-pin connector is used to send the DC control signal and power supply to an auto-iris type lens.
4
English
3
PARTS NAMES
7 Lens mount cap
The cap is installed to protect the lens mount section.
Remove the lens mount cap before installing a lens (sold separately).
8 Flange-back adjustment screw (FLANGE BACK ADJ.)
9 Flange-back lock screw (FLANGE BACK LOCK)
F Camera installation bracket
9
7
8
F
2
1
3
2
The bracket can be fixed at the top or bottom of the camera. When fixing the bracket, be sure to use the
longer screws and install the shorter screws on the opposite side to seal the openings.
1
1 Shorter screws: M3 x 4
2 Longer screws: M3 x 6
3 Camera mounting screw hole: 1/4"-20 UNC
CAUTION:
When installing the camera support, select a location that can support the total weight of the
camera and accessories.
4
English
CONCERNING AUTO-IRIS LENSES
DC type auto-iris lens
A lens without amplifier circuit that operates only on a DC power source. In general, this type of lens is
referred to as DC type coil lens or DC type non-amplifier lens.
(Set the A.I. LENS switch to the DC position.)
DC
VIDEO
VIDEO type auto-iris lens
A lens with amplifier circuit that operates on video signal and DC power source. In general, this type of lens is
A. I.
LENS
referred to as EE amplifier type lens.
ALC and LEVEL volume level controls are available on the lens for iris adjustments.
(Set the A.I. LENS switch to the VIDEO position.)
Compatible auto-iris lenses
1/2 inch Sanyo DC type lens
VCL-CS12GY: Standard angle, f= 12 mm
VCL-CS6GY: Wide angle, f= 6 mm
1/2 or 2/3 inch VIDEO type lens
Semi-wide angle, f= 9 mm
Standard angle, f= 12 mm
Telephoto angle, f= 16 mm
VCL-CS3GY: Ultra-wide angle, f= 3.7 mm
If using a VIDEO type auto-iris lens
• Set the ALC and LEVEL controls on the lens to adjust the iris. Normally the ALC volume should be turned
all the way to Av (Average).
• Depending on the type of lens used, the lens may not perform properly. In such a case, adjust the LEVEL
volume on the lens casing to correct.
English
5
MOUNTING THE LENS
Please use a DC type auto-iris lens (sold separately).
Checking the lens mount
Do not use a lens if length “L” is more than 7 mm. If not, that may damage the camera and prevent
proper installation.
L
1
2
Remove the lens mount cap from the camera.
Install the auto-iris lens.
CS mount type lens
1
Carefully align the lens mount with the camera opening, then turn the lens slowly to install it.
C mount type lens
C mount type lens
2
To allow for flange-back adjustment, install the supplied C-mount adaptor on the lens mount, then
carefully align the lens mount with the camera opening and turn the lens slowly to install it.
3
Connect the lens plug to the lens iris output connector (LENS) on the side of the camera.
When using lenses from other makers, the plug shape may not correspond to the terminal on the camera.
In such a case, remove the original plug and using a soldering iron, connect the supplied lens iris plug
according to the diagram. (Refer to page 7.)
CAUTION:
When using an auto-iris lens, the supplied clamping core (B) must be installed on the lens wire, in order to
prevent electromagnetic interference to the other devices connected.
3
2
CS mount
type lens
6
English
MOUNTING THE LENS
Rewiring the lens cable in the lens iris plug
1
2
Prepare the lens cable.
1
2
Cut the cable at the plug, then remove approx. 8 mm of the cable sheath and strip about 2 mm from each
wire.
Install the lens iris plug.
Solder the cable to the pins following the correct pin layout (refer to the table and illustrations), then close
the plug cover.
Pin layout
DC type lenses
VIDEO type lenses
+12 V DC (50 mA max.)
1 3
2 4
1
2
3
4
Brake coil (–)
Brake coil (+)
Drive coil (+)
Drive coil (–)
1
2
3
4
Not used
Video output (1.0 Vp-p, high impedance)
Ground (for video signal and DC power)
Flange-back adjustment
If the pick-up surface is not correctly positioned with relation to the lens focal point, the picture will be out of
focus (in particular when using auto-iris power zoom lenses, sold separately). If that is the case, adjust the
flange-back position as described below.
1
1
Using a + screwdriver, loosen the FLANGE BACK LOCK screw (M2:+).
Set the zoom lens to the maximum telephoto position, set the focus using the focus ring on the lens.
ADJ.
LOCK
2
1
2
3
Set the zoom lens to the maximum wide angle position, set the focus using the FLANGE BACK ADJ. screw.
Repeat steps 2 and 3, until the image stays in focus when changing from a telephoto shot to a wide angle shot.
When the setting is complete, tighten the FLANGE BACK LOCK screw.
3
English
7
CONNECTIONS
Basic connection for monitoring or recording
The peripheral devices (VCR, monitor, lens, etc.) and cables are sold separately.
(A)
1
1
2
Make the video signal connection between the camera and the monitor or time lapse VCR.
Connect DC connecting cord from the AC adaptor to the 12 V DC input terminal on the camera.
• When using this unit, the supplied clamping core (A) must be installed on the power cord, in order to
prevent electromagnetic interference to the other devices connected.
2
WARNING:
• This AC adaptor is specially conceived for this camera. Never use another type of AC adaptor with this
camera, and do not use this AC adaptor to power other types of cameras.
• Not for use with toys.
3
• Never try to disassemble or modify the AC adaptor.
3
Insert the plug of this power cord into a wall outlet.
The POWER indicator (A) will light. Adjust the picture on the monitor using the Brightness and Contrast
controls.
Coaxial cable type and maximum length
• Cable type RG-59U (3C-2V), 250 m maximum.
• Cable type RG-6U (5C-2V), 500 m maximum.
• Cable type RG-11U (7C-2V), 600 m maximum.
CAUTION:
• The RG-59U type cable should not be run through electrical conduits or through the air.
• Using CCTV/Video-grade coaxial cable.
(Video signal connections)
: VIDEO IN
: VIDEO OUT
8
English
SETTINGS
d
High speed electronic shutter setting
VR401
L
E
V
E
L
Normally, the speed setting switches for the high speed electronic
shutter are all set to the OFF position. This sets the electronic shutter
speed to 1/50 sec. The switches can be set as indicated in table A to
select one of the 8 speeds available.
EI
L
H
ON
OFF
ON
ON
1
DC
VIDEO
2
3
BLC
A. I.
LENS
E. S.
CAUTION:
a
b c
• When using the high speed electronic shutter, the EI/BLC switch
must be set to the OFF position.
• Using the high speed electronic shutter indoors with low lighting,
will give darker pictures. In such a case, add some lights to make
sure the lighting is sufficient. If the lighting is very bright, pay
attention to the light angle in order to avoid or minimize the
smear phenomenon effect.
Control name
Position
High speed electronic shutter switches (E.S.)
All OFF:
1/50 sec
a
b
c
d
Electronic iris (EI)/Backlight compensation
(BLC) switch
OFF
Table A
1
1/50
ON
2
3
4
5
6
7
8
Auto-iris lens switch (A.I. LENS)
Refer to page 5
DC
1/120 1/250 1/500 1/1000 1/2000 1/4000 1/10000
ON
1
ON
1
ON
1
ON
1
ON
1
ON
1
ON
1
2
3
2
3
1
2
3
2
3
2
3
2
3
2
3
2
3
Lens iris level volume (LEVEL)
about centre
(Unit: sec.)
English
9
SETTINGS
Electronic iris function setting
Lens iris adjustment
Use a manual or fixed iris lens and set the lens
aperture to the shortest F stop. Set the EI/BLC
switch to EI-ON position.
If using a DC type auto-iris lens, you will need to set the LEVEL
(VR401) volume when shooting in the conditions described below.
EI
L (counterclockwise): To decrease the contrast
ON
OFF
ON
Note:
H (clockwise): To increase the contrast
BLC
Please refer to the specifications for dynamic
range of the electronic iris.
• If shooting simultaneously in a dark room
and through a bright window.
VR401
L
E
V
E
L
• If the subject background is extremely
CAUTION:
bright or dark.
• The electronic iris is suitable for normal indoor use. When the EI/BLC
switch is set to the EI-ON position, do not use an auto-iris lens.
L
H
• If the brightness of the picture on the
monitor is not correct.
• If used under fluorescent light, the image may flicker. In such a
case, change to incandescent lighting or set the EI/BLC switch to
the OFF position and use an auto-iris lens.
• When shooting bright subjects, pay attention to the light angle in
order to avoid or minimize the smear phenomenon effect.
When using an auto-iris lens (for indoor/outdoor use)
Set the EI/BLC switch to the OFF position.
CAUTION:
If conditions are outside the electronic iris operation range or more
than the maximum illumination, it will cause saturation of the CCD. In
that case, use a manual iris lens.
10
English
SETTINGS
TROUBLESHOOTING
Before taking the camera for repairs, please check below to make
sure that the camera is used correctly. If it still does not perform
correctly, please consult your dealer or a Sanyo Authorized Service
Centre.
Backlight compensation setting
Use an auto-iris lens and set the EI/BLC switch to the BLC-ON
position, to engage the backlight compensation function.
Use an auto-iris lens. Set the EI/BLC switch to the BLC-ON position.
No picture on the monitor screen
EI
• Is the power turned on to all connected devices? Is the voltage correct?
• Are all the signal connecting cables correctly connected?
• Is the lighting sufficient?
ON
OFF
ON
BLC
• Has the lens cap been removed?
• Is the lens type (DC or VIDEO) correctly selected?
Depending on the type of lens, the A. I. LENS switch must be set
If using a VIDEO type auto-iris lens
accordingly.
• The ALC volume on the lens should be turned all the way to Av
(Average).
• Is the iris control correctly set?
A: When using a DC type lens, the LEVEL volume (inside the
• If the backlight compensation function does not compensate
properly for the conditions, set using the LEVEL volume on the
lens.
camera casing) should be adjusted.
B: When using a VIDEO type lens, the LEVEL volume (on the
lens) should be adjusted.
CAUTION:
The electronic iris function and the backlight compensation function
cannot operate simultaneously.
The picture is not clear
• Is the monitor correctly adjusted?
• Is the flange-back position correctly set?
• Is the lens focus correctly adjusted?
• Are the lens surfaces clean?
If there is dust or finger prints on the lens, the image quality will
deteriorate. To clean the lens use a soft cloth or a commercially
available lens cleaning set.
English
11
SPECIFICATIONS
Camera
Power supply
: 12 V DC/150 mA
(without auto iris lens)
12 V DC/200 mA
(with auto iris lens)
: Approx. 330 g (without lens)
Scanning system
: CCIR standard
(625 TV lines, 25 frames/sec.)
Interlace
: PLL 2:1 interlace
Weight
Image device
Picture elements
: 1/2 inch solid state image device CCD
: 795 (H) x 596 (V)
Effective picture elements : 752 (H) x 582 (V)
Synchronizing system
Resolution
: External sync (Automatic switching)
: 560 TV lines horizontally, 350 TV
lines vertically
: 1.0 Vp-p/75 ohms, composite
: More than 50 dB
AC Adaptor:
Environmental conditions : Temperature: –10˚C ~ +50˚C
Humidity: less than 90%
: 220 – 230 V AC 50Hz
: 3.3 W (with camera head)
4.2 W (with camera head, auto iris
lens)
Video output level
Video S/N ratio
Minimum required
illumination
(incandescent lighting)
Power requirement
Power consumption
: Approx. 0.02 lux with a F 1.2 lens,
approx. 0.03 lux with a F 1.4 lens
Weight
: Approx. 440 g
Backlight compensation
: Manual ON/OFF switching, zone light
measuring system
(Active when using an auto-iris lens)
Electronic iris function
Electronic shutter
: Manual ON/OFF switching
: 8 speeds, selectable by switches:
(1/50, 1/120, 1/250, 1/500, 1/1000,
1/2000, 1/4000, 1/10000 sec.)
SERVICE
This camera is a precision instruments and if treated with care, will
provide years of satisfactory performance. However, in the event of a
problem, the owner is advised not to attempt to make repairs or open
the cabinet. Servicing should always be referred to your dealer or
Sanyo Authorized Service Centre.
Electronic iris range
: 0.02 lux to 10,000 lux (F 1.2, lens)
0.03 lux to 15,000 lux (F 1.4, lens)
: 12.5 mm 0.8 mm
Flange-back
Gamma correction
Lens mount
: γ = 0.45
: CS mount (or C mount with the
supplied adaptor)
Environmental conditions : Temperature: –10˚C ~ +50˚C
Humidity: less than 90% (no
condensation)
12
English
SPECIFICATIONS
ACCESSORIES
1 C mount adaptor (5 mm)..........................................................1 pc.
The C mount adaptor must be used to be able to install a C mount
lens on the camera.
2 Lens iris plug (4-pin)..................................................................1 pc.
3 AC adaptor..............................................................................1. pc.
4 AC adaptor mounting plate......................................................1 pc.
:With 3 fixing screws
Dimensions: mm
56
108.5
99.5
1.5
VIDEO OUT
VS IN
POWER
45
SEE INSTRUCTION MANUAL
5 Clamping core A......................................................................1. pc.
6 Clamping core B......................................................................1. pc.
+
–
12V DC
NC
11
1/4”–20 UNC
12
28
1
5
2
6
3
4
22
75
50
Approx. 1.8 m
Approx. 1.8 m
55
Features and specifications are subject to change without prior
notice or obligations.
English
13
SANYO Electric Co, Ltd
1AC6P1P1978--
Printed in Japan
L72H2/XE2(0399NI)
|