Magnadyne MV PI300A User Manual

Model: MV-PI300A  
Installation and User Guide  
For use in vehicles with 12V negative ground electrical systems only. Use of the MV-PI300A with a non 12V negative ground  
electrical system can result in failure of the unit and or a blown fuse.  
Specifications  
Safety Features  
• Input Voltage Range: . . . . . . . . . . . . . . . . . . . . . 10-15V DC  
• Input Full Load Current: . . . . . . . . . . . . . . . . . . . . . . . . 30A  
• Standby Input Current: . . . . . . . . . . . . . . . . . . . . . . . <0.32A  
• Output Voltage (AC): . . . . . . . . . . . . . . . . . . . . . 110V ± 5%  
• Continuous Output Power: . . . . . . . . . . . . . . . . . . . . . 300W  
• Dimension . . . . . . . . . . . (L) 155mm (W) 73mm (H) 73mm  
• Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2lbs.(900g)  
• Replacement Fuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35A  
• Auto Operating Fan  
• Overload Protection  
• Output Short Circuit Protection  
• Reverse Polarity Battery Protection  
Trouble Shooting  
When the Power Inverter Does Not Appear to be Functioning Properly, Check the Following Trouble Shooting Procedures.  
1) Poor Contact: clean contact parts thoroughly.  
(b) Disconnect some of the appliances. (c) Check the  
power consumption of your AC appliance, make sure it is  
below 300W.  
2) Receptacle Has No Power Output: (a) Check fuse, replace  
damaged fuse with same amperage. (b) Check receptacle  
wiring, repair if necessary.  
Warning Signals  
• Low Battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . BI BI BI  
• Over Heating . . . . . . . . . . . . . . . . . . . . . . . . . . BI BI BI BI  
• Over Load . . . . . . . . . . . . . . . . . . . . . . . . . . . . BI BI BI BI BI  
• Output Short . . . . . . . . . . . . . . . . . . . . . . . . BIBIBIBIBIBIBI  
3) Output Short, Heat Overload: Under heavy loads, the AC  
output will decrease. This is to protect the Unit from  
overheating, (a) turn off the unit until it cools down  
Connection  
Mounting  
Acceptable mounting positions  
Note: be sure to leave at least 1" around the unit for proper  
ventilation.  
Caution! DO NOT reverse power input connection, it can  
cause severe damage to the power unit.  
Under-Counter  
Mount  
(-)GROUND  
(+)12V  
Red Wire: Connect to  
WARNING! Do Not Reverse Polarity  
Switched +12V  
Black Wire: Connect  
to Ground  
Floor Mount  
MV-PI300AINS  
Rev. A 6-21-02  
© 2002 Copyright Magnadyne Corporation  
1111 West Victoria Street  
Compton, CA 90220  

PYLE Audio Mobile Audio System PLDTF5M User Manual
OPPO Digital OPPO BDP 80 User Manual
Nostalgia Electrics CSD 250 User Manual
Nokia BH 101 User Manual
Nikon D40x User Manual
Nikon Camcorder WT 2A User Manual
Miele KWT1611SF User Manual
Lanzar Car Audio OPTISCION OPTS2502 User Manual
Kodak K625 User Manual
JVC KD S611 User Manual