BE-IR30 / 31
Infrared B/W Camera Module
Operation Guide
Please read this operation Guide carefully for proper operation, and keep it for future refernce.
1. Introduction
Thank you very much for your purchase of the Hitachi BE-IR30/31 Black and White Camera
Module.
Prior to using this camera , read this manual carefully.
2. General
The BE-IR30/31 is a monochrome camera module featuring sensitivity in the near infrared
spectrum using a 1/3-inch size CCD imaging device. Resolution is outstanding, while the very
small size provides optimum suitability for incorporation into equipment where space is limited.
Model coding
BE-IR3
Signal system
Optical system
N: EIA
P: CCIR
A: Without lens mount
B: With lens mount and board lens
C: With pinhole lens mount*
0: Internal sync
Synchronization
1: External sync
*Type C is mount only. Specify at time of order when requiring pinhole lens,
CS or C mount adapter
3. Composition
1) Black and white camera module ・・・・・・・・・・・・・・・・・・ 1
2) Interface cable ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 1
Note : The standard accessory cable is 300 mm signal conductor.
Different length cable requires shielding to avoid external noise.
4. Specifications
1) Imaging device
1/3 inch interline CCD
EIA : 811(H)×508(V)
CCIR : 795(H)×596(V)
EIA : 768(H)×494(V)
CCIR : 752(H)×582
EIA : 6.35(H)×7.4(v)µm
CCIR : 6.5(H)×6.25(V)µm
No. of pixels
No. of effective pixels
Pixel pitch
BE-IR30 / 31
2
4 Specifications
2) Sensing area
EIA : 6.00(H)×4.96(V)mm
CCIR : 6.00(H)×4.96(V)mm
Conforming to EIA or CCIR.
2:1 interlaced
3) Signal format
4) Scanning system
5) Hor. scanning frequency
EIA : 15.734 kHz
CCIR : 15.625 kHz
EIA : 59.94 Hz
6) Vert. scanning frequency
7) Sync system
CCIR : 50 Hz
BE-IR30 : Internal sync
BE-IR31 : External sync
8) External sync input
HD & VD : 5V peak-to-peak negative
Input impedance : 1kΩ
Frequency deviation : ±1%
1.0 Vp-p, 75Ω, unbalanced
Video component : 0.7 Vp-p
Sync component : 0.3 Vp-p negative
EIA : 570(H)×380(V) TV lines
CCIR : 560(H)×380(V) TV lines
56 dB
9) Video output
10) Resolution
11) Signal to noise ratio
12) Auto electronic shutter
13) Automatic gain control (AGC)
14) Integration mode
Provided (factory setting OFF)
Max. 32 dB approx. Fixed gain(factory setting)
Field integration mode
15) Gamma correction
0.45
0.45ON (factory setting) or 1.0
Selected by changing chip parts
30 lux , F4, 3200k
16) Sensitivity
17) Minimum illumination
18) Power supply voltage
19) Power consumption
20) Ambient conditions
0.3 lux , F1.4 , AGC and gamma on
9 ± 0.5 VDC
Approx. 150mA
Operating : -5 to 45℃ , 90% RH or less
Storage : -10 to 60℃ , 70% RH or less
BE-IR30 / 31
3
4 Specifications
21) Standard lens
f3.8 (BE-IR30B/31B only)
Focal distance f
F value
3.8 mm
2.0
Picture angle H 70.9
52.9
V
21) Dimensions
22) Mass
BE-IR30A/31A: 34 (W) × 34 (H) × 20 (D) mm
BE-IR30B/31B: 34 (W) × 34 (H) × 32 (D) mm
(less lens)
BE-IR30C/31C: 34 (W) × 34 (H) × 24 (D) mm
BE-IR30A/31A: Approx. 15g (less cable)
BE-IR30B/31B: Approx. 26g (including cable, less lens)
BE-IR30C/31C: Approx. 19g (less cable)
• BE-IR30A/31A mount adapter (LA-IR20)
23) Options
• BE-IR30B/31B lenses
Focal distance f (mm) 2.5
6.0
2.0
F value
2.0
Picture angle
H
V
117.9 45.5
85.3
33.8
• BE-IR30C/31C pinhole lenses
Focal distance f (mm) 3.2
3.7
F value
4.5
4.5
Picture angle
H
V
90.6
56.9
72.6
54.2
• BE-30C/31C CS mount adapter
BE-30C/31C C mount adapter
(use together with CS mount adapter)
NOTE
Auto electronic shutter
This is normally set to off at the factory.
If using a board lens (type B or C), the auto electronic shutter can be supplied from the factory at the on
setting. Since changing the setting is somewhat troublesome (requires tools and technical skill for
working with miniature parts) whenever possible, specify desired on or off setting at time of order.
Also note that certain types of lighting (e.g., fluorescent or mercury vapor) may cause flicker to appear on
the monitor screen due to effects of power line frequency.
BE-IR30 / 31
4
5. Notes to users
Power supply
z Connect a 9V DC voltage (8.5 to 9.5V) from an external regulated DC power supply.
z Use a stable power supply without ripple and noise.
z Prior to turning on the power switch , check that the polarities of the power cable are
correct , referring to the connection diagram (Page 11 , 12)
To protect CCD (sensor)
z Do not touch the glass surface of the CCD sensor to avoid deterioration in picture
quality due to dirt and scratches.
z If the glass surface of the sensor should become dusty or dirty , remove dust or dirt
carefully with a cotton-tipped applicator. Do not wipe the surface with dry cloth or
paper tissue to avoid possible damage to the glass surface by static electricity.
Protection of camera
z Do not use or store the camera under direct sunlight , at a place exposed to rain or
snow , or at a place where flammable or corrosive gas is present.
z When housing the camera in a camera case , use the utmost care regarding rise of
internal temperature.
When casing the camera , the temperature normally rises by 10 to 20℃ , compared
with the outside air temperature. The camera operates in the temperature range from
-5 to 45℃. If the camera is used or left in high temperature environment for hours ,
the life of the camera may be shortened.
z Do not drop the camera. Do not apply strong shock or vibration to the camera.
z Before connecting or disconnecting a connector , turn off the camera and be sure to
hold connector body to connect or disconnect the connector.
Camera arrangement
z Mutual interference noise can occur if multiple cameras are arranged in close proximity.
Separate the cameras to the extent possible.
When camera units are installed directly into other equipment , external noise can
prevent a normal picture. In such cases , shield the camera units.
The camera can be damaged by static electricity. Use ample care when installing
and arranging.
Auto electric shutter
z In regions using 50 Hz power line frequency , flicker can appear on the monitor screen
from light sources such as fluorescent or mercury. In such cases , release the auto
electronic shutter.
BE-IR30 / 31
5
5. Notes to users
Phenomena inherent to CCD imaging device
Following are phenomena inherent to a CCD imaging device , and not defects.
z Smear and blooming
When strong light (lamp , fluorescent lamp , reflected light , etc.) is shot , pale bands
are displayed vertically above and below the light.
In this case , change the angle of the camera so that such strong light does not enter
the camera through the lens.
z Fixed pattern noise
When the camera is operated in a high temperature , fixed pattern noise may appear
on the entire screen.
The higher the sensitivity of camera , the more this fixed pattern noise appears.
z Moire
When fine patterns are shot , moire may be displayed.
z The CE mark is required when exporting to Europe. Obtain the necessary
authorization for the customer’s system. Enclose the camera in a shielded case and
use shielded cable.
BE-IR30 / 31
6
6. External view
BE-IR30B/31B
BE-IR30 / 31
7
6. External view
BE-IR30C/31C
BE-IR30 / 31
8
6. External view
BE-IR30A/31A
7. Optical dimensions
Lens
Lens-mount
1.4 ± 0.2
19.2 ± 0.5
(C-mount)
Extension of optical path due
to the thickness of CCD glass
is considered.
CCD
Base plate
Imaging face
BE-IR30 / 31
9
8. Installation
When installing the camera in a housing or unit of equipment, secure with two M2 screws
inserted into the 2.5 mm diameters holes of the SENS board base plate.
Two 2.5 mm Dia.
SENS board
1. Use the SENS board holds to install the camera. Avoid using only the Main board,
due to risk of damage to the board connector.
Notes :
2. Avoid unnecessary stress on the printed board when engaging and disengaging the
connectors.
3. The screws securing the base plate and SENS board protrude a maximum of 2 mm
from the base plate. Observe these screws do not contact the housing or installed
equipment.
BE-IR30 / 31
10
9. Typical connection
BE-IR30
Image processor or
Video monitor
Connector
B7B-ZR
75Ω
ON
VIDEO
IN
OUT
OFF
(Note 1)
Housing
ZHR-7
BLK
YEL
GRN
RED
Regulated power supply
(More then 300 mA)
Note1 : • When more than one video monitor is connected in
series , set the 75Ω termination switch on the last unit
to ON.
-
+
DC9V
(Note 2)
Note2 : • Supply voltage range : 8.5 to 9.5V
• Be sure to check the polarities of the power source
before turning on the external DC power supply.
BE-IR30 / 31
11
9. Typical connection
BE-IR31
Image processor or
Video monitor
Connector
B7B-ZR
75Ω
ON
VIDEO
IN
OUT
OFF
(Note 1)
Housing
ZHR-7
BLK
YEL
GRN
RED
Regulated power supply
(More then 300 mA)
HD
VD
GND
External sync signal
-
+
Note1 : • When more than one video monitor is connected in
series , set the 75Ω termination switch on the last unit
to ON.
DC9V
(Note 2)
Note2 : • Supply voltage range : 8.5 to 9.5V
• Be sure to check the polarities of the power source
before turning on the external DC power supply.
BE-IR30 / 31
12
10. External sync (BE-IR31)
Supply sync signals (HD and VD) for BE-IR31 operation. Refer to connection on page 12.
z
z
z
Horizontal and vertical drive signal inputs
HD EIA: f(H) = 15.734 kHz ±1 %
VD EIA: f(V) = 59.94 Hz (f(V) = f(H) ÷ 262.5)
Input level
HD 4 to 6 Vp-p negative
VD 4 to 6 Vp-p negative
Input impedance
1 kΩ
z Drive signal input waveform
z Horizontal drive signal (HD)
T=1/f(H)
z Vertical drive signal (VD)
T=1/f(V)
4~6Vp-p
4~6Vp-p
Approx. 6.7µs
Approx. 0.6ms
z HD and VD phase relationship
VD
Set HD and VD fallings edges to the same phase (0 ± 5 µs)
HD
BE-IR30 / 31
13
11. Function setting and changes
When changing the function settings , perform the work with thorough care. Be sure to use
anti-static measures such as a grounding band. Also observe safety precautions when
soldering to avoid burn and fire hazards.
Hitachi Denshi assumes on liability for damage or injury resulting from such work.
Since the function setting can be provided at the time of shipment , consult a Hitachi Denshi
representative.
11-1 AGC on / off
Factory setting is AGC off (fixed gain). If necessary in the application, AGC can be set to on.
When the AGC is off, the gain can be changed by turning RV201.
Set AGC on by changing the indicated chip parts.
Gain
fixed gain
AGC
R211
0Ω
R212
Absent
0Ω
Factory setting
Remove
Location of chip resistor (Main board side A)
BE-IR30 / 31
14
11. Function setting and changes
11-2 Gamma response
The factory setting is gamma on. If necessary , the gamma response can be changed as
follows.
Change the gamma response by changing the chip part.
Gamma(γ)response
R217
Absent
0Ω
R218
R219
ON
0Ω
0Ω
Factory setting
OFF
Remove Remove
0Ω : Part code
RME1784
Description
ERJ3GEYJ0R00V
Location of chip capacitors (Main board side B)
BE-IR30 / 31
15
11. Function setting and changes
11-3 Auto electronic shutter on / off
Factory setting for auto electronic shutter is off. If necessary , it can be set to on.
Absent the R259 , R260 chip to set the auto electronic shutter to on.
Auto electronic shutter
R259
0Ω
R260
0Ω
OFF
ON
Factory setting
Absent
Absent
0Ω : Part code
RME2068
ERJ2GE0R00X
Description
Location of chip resistors (Main board side B)
BE-IR30 / 31
16
11. Function setting and changes
11-4 Changes to fixed shutter mode
The fixed shutter mode can be changed by replacing the chip parts indicated below.
Mode
R259
R260
R261
R262
R263
R264
R265
10k
R266
27k
R267
10k
R268
10k
R269
27k
Factory
setting
Normal mode
0Ω
0Ω
Absent
0Ω
Absent 6800
Auto electronic
shutter mode
Remove Remove Absent
0Ω
Absent
Absent
↑
↑
↑
↑
↑
↑
EIA
1/100
CCIR
1/120
Remove
0Ω
0Ω
0Ω
0Ω
Remove
0Ω
0Ω
Remove
Remove
1/250
↑
↑
↑
↑
↑
↑
↑
↑
↑
0Ω
↑
↑
↑
↑
↑
↑
↑
↑
↑
Remove Remove
0Ω 0Ω
Remove Remove
0Ω 0Ω
Remove Remove
0Ω 0Ω
Remove Remove
0Ω
Remove
0Ω
1/500
Absent Remove
1/1000
1/2000
1/5000
1/10000
1/100000
↑
0Ω
↑
↑
↑
Remove Absent Remove Remove
0Ω
0Ω
0Ω
0Ω
Remove
0Ω
↑
↑
0Ω
↑
Absent Remove
Remove
0Ω
↑
↑
R259 , R260 : 0Ω Part code
RME2068
Description
ERJ2GE0R00X
RME1784
Others
: 0Ω Part code
Description
ERJ3GEYJ0R00V
(Main board side A)
(Main board side B)
Location of chip resistors
BE-IR30 / 31
17
11. Function setting and changes
11-5 BE-IR30 external sync
The BE-IR30 factory setting is for internal sync. If required, this can be changed to external
sync by changing chip parts.
Change the following chip parts for external sync operation.
Sync system
Internal
R280
100 Ω
Delete
R281
Absent
0 Ω
R282
Absent
100 Ω
R284
0 Ω
Factory setting
External
Delete
0 Ω:
Part code
Type
RME1784
ERJ3GEYJ0R00V
RME1797
100 Ω: Part code
Type
ERJ3GEYJ101V
(Main board side A)
(Main board side B)
Location of chip resistors
BE-IR30 / 31
18
11. Function setting and changes
11-6 BE-IR31 internal sync
The BE-IR31 factory setting is for external sync. If required, this can be changed to internal
sync by changing chip parts.
Change the following chip parts for internal sync operation.
Sync system
External
R280
Absent
100 Ω
R281
0 Ω
R282
100 Ω
Delete
R284
Absent
0 Ω
Factory setting
Internal
Delete
0 Ω:
Part code
Type
RME1784
ERJ3GEYJ0R00V
RME1797
100 Ω: Part code
Type
ERJ3GEYJ101V
(Main board side A)
(Main board side B)
Location of chip resistors
BE-IR30 / 31
19
11. Function setting and changes
11-7 HD and VD output (BE-IR30 only)
The BE-IR30 can be provided with horizontal and vertical drive outputs by changing chip parts.
Change the following chip parts to provide HD and VD outputs.
R233
R239
Absent
0 Ω
R240
0 Ω
R241
Absent
0 Ω
R242 R248
R249
0 Ω
R250
Absent
0 Ω
Factory setting
0 Ω
0 Ω
Absent
0 Ω
HD & VD output Delete
Delete
Delete
Delete
0 Ω:
Part code
Type
RME1784
ERJ3GEYJ0R00V
Connector pin assignments after
change
Pin No.
Signal
Video out
Video GND
GND
1
2
3
4
5
6
7
+9V
HD out
VD out
HD/VD GND
Note: The accessory cable cannot
be used for signal outputs.
Location of chip resistors(Main board side B)
BE-IR30 / 31
20
12. Options
LA-IR20 Mount adapter dimensions
Remove c-mount attachment to use as cs-mount.
BE-IR30 / 31
21
12. Options
BE-IR30A/31A and LA-IR20 combined dimensions
BE-IR30 / 31
22
12. Options
BE-IR30C/31C and CS mount adapter (option) combined dimensions
BE-IR30 / 31
23
Spectral sensitivity (typical example)
1
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0
400
500
600
700
800
900
1000
Wavelength(nm)
BE-IR30 / 31
24
C a u t i o n
The specifications of this equipment are subject to change without notice for improvement.
Prior to placing your order , be sure to confirm that these specifications are the latest ones.
Hitachi Denshi guarantee that the equipment shipped from our factory conforms to the Hitachi
Denshi’s standard warranty conditions and perform quality control within the range necessary to
perform the warranty.
W a r r a n t y a n d A f t e r - s a l e s S e r v i c e
(1) The guarantee period is one year after the date of purchase. However , the defects due to
erroneous use or intentional act are excluded.
(2) As the defect after expiration of the guarantee period , Hitachi Denshi will repair the equipment if
the intended function is restored by the repair work , and the cost is changed to a customer.
(3) Hitachi Denshi is not liable for the losses caused when the equipment is used in a system used for
business trades , production process , medical fields , crime prevention applications , etc.
(4) The parts used in the equipment have their respective lives. The lives of such parts will be
shortened under the environments of high temperature or high humidity. When the stable
operation is required for a long time , it is recommended to perform periodical maintenance and
inspection every year or every two years.
Dec 27 2000
Jul 24 2000
Dec 9 1999
Aug 5 1999
BE-IR30 / 31
25
|