Hamilton Beach Blender 840065601 User Manual

Tempest  
Series Blenders  
Operation Manual  
Mélangeurs de series  
Tempest  
Manuel d’utilisation  
Licuadoras de series  
Tempest  
Manual de uso  
840065601  
Technical Service: 1-866-285-1087 (www.commercial.hamiltonbeach.com)  
Blender Safety  
IMPORTANT SAFETY INSTRUCTIONS  
WARNING – When using electrical appliances, basic safety precautions should be followed, including  
the following:  
To prevent damage to blender, jar, or cutter  
assembly, DO NOT move or shake blender  
while in operation. If blending action stops during  
operation, turn blender OFF, remove jar from  
base, remove jar cover, and use a thin rubber  
spatula to push mixture towards cutters.  
Do not spray the base with a high-pressure  
spray gun.  
Disconnect power before cleaning or servicing.  
To prevent burns from hot liquids splashing out  
of the jar, always remove the filler cap of the  
container cover before blending hot liquids.  
Do not operate any appliance with a damaged  
cord or plug or after the appliance malfunctions,  
or is dropped or damaged in any manner.  
Return appliance to the nearest service facility  
for examination, repair, or electrical or  
mechanical adjustment.  
If the supply cord of this appliance is damaged,  
it must be replaced by the manufacturer or its  
service agent or a similar qualified person. If fitted  
with a non-rewirable U.K. plug, the 13 amp fuse  
approved by ASTA to be B.S. 1362 must be used.  
If you need a replacement fuse carrier, it must be  
replaced by the same colour coded carrier with  
the same markings. Fuse covers and carriers  
can be obtained from approved service agents.  
IMPORTANT: If the molded plug is cut off,  
dispose of it immediately. The plug is not rewirable  
and would cause a shock hazard if inserted into  
a socket.  
Read all instructions.  
Plug into a grounded outlet.  
Do not touch surfaces that may be hot.  
Use handles or knobs provided.  
Extreme caution must be used when moving an  
appliance containing hot oil or other hot liquids.  
Do not use appliance for other than intended use.  
To protect against electrical shock, do not  
immerse cord, plug, or blender base in water  
or any other liquid.  
Close supervision is necessary when any  
appliance is used by or near children.  
The use of accessory attachments not recom-  
mended by Hamilton Beach may cause injuries.  
To reduce risk of personal injury, unplug cord  
from outlet when not in use, and before putting on  
or taking off parts or doing any other servicing of  
the blender.  
Do not let cord hang over edge of table or  
counter or touch hot surfaces.  
Do not place on or near a hot gas or electric  
burner or in a heated oven.  
To reduce risk of personal injury and to prevent  
damage to blender or jar and cutter assembly,  
DO NOT insert utensils into blender jar while  
operating blender, or store utensils in the blender  
jar when it is not in use.  
Avoid contacting moving parts.  
Blades are sharp. Handle carefully.  
Inspect jar and cutter assembly daily. Check  
cutter for wear, nicks, or broken blades. Replace  
jar and cutter assembly at least every 12 months.  
Do not defeat the jar pad sensors.  
Do not use outdoors.  
For a complete operation manual in this  
language, please visit our website at  
or call 910-692-2223.  
This appliance is intended for short periods  
of operation, with a rated operating time of  
3 minutes.  
SAVE THESE INSTRUCTIONS –  
Blender Operation – Quick Start Guide  
1. Place the blender on a dry, level surface.  
4. Set the controls to your preference.  
2. Make sure the power switch is in the “off” or O  
position. Plug the blender into a grounded electrical  
outlet.  
5. Move the power switch to the “on” or I position  
(except model 915).  
6. Move the power switch to start (run) or  
3. Place the jar on the base with ingredients and jar  
position.  
lid in place.  
3
Caring for the Blender  
Cleaning the Blender  
wWARNING  
wWARNING  
Cut Hazard  
Electrical Shock Hazard  
Plug into a grounded outlet.  
Do not remove ground.  
Always place cover on jar when blending.  
Do not put hands, spoons, or other utensils  
in jar when blending.  
Do not use an adapter.  
Failure to follow these instructions can  
result in broken bones or cuts.  
Do not use an extension cord.  
Failure to follow these instructions can  
result in death, fire, or electrical shock.  
Sanitizing  
If the blender will not be used again within 1 hour,  
sanitize the container in the following manner:  
Cleaning  
The jar should be cleaned immediately AFTER  
EACH USE. The jar can be cleaned in the  
following manner:  
1. After washing the jar, fill it with a cold chlorine-  
based sanitizing solution that has a minimum  
chlorine concentration of 100 parts per million.  
See recommended solution below.  
1. Fill the jar half full with warm water,  
122 degrees F (50 degrees C).  
2. Add a drop of liquid detergent or 12 teaspoon of  
detergent powder.  
2. Place the cover/filler cap on the jar and blend on  
C cycle or the High setting for a minimum of 2  
minutes.  
3. Place the cover/filler cap on the jar and blend on  
C cycle or the High setting for 30 seconds.  
3. Empty the jar but do not rinse.  
4. Dry the jar by placing it on the blender base and  
turn the blender on C (Slide-step cycle) or the  
High setting for 2 seconds.  
4. Turn the blender off, and then rinse the jar  
and wipe down to dry. Do not disassemble  
the cutter assembly.  
5. Wash the jar cover/filler cap in warm, soapy  
water. Rinse and let dry.  
Recommended Sanitizing Solution:  
The sanitizing solution should consist of 1  
tablespoon of household bleach per 1 gallon of  
clean, cool water (60° F, 16° C) mixed according  
to the instructions on the bleach. When using a  
sanitizing solution other than that recommended,  
the sanitizing solution concentration should be  
tested using commercially available test strips  
and should indicate a concentration between  
100 and 200 parts per million of bleach to water.  
6. Unplug the blender.  
7. Wipe down the blender base with a damp cloth.  
4
Caring for the Blender  
Troubleshooting Guide  
Problem . . .  
Solution . . .  
A system fault has been detected. Unplug unit for 5 seconds, and then plug unit  
back in. If light is still red, unplug unit for 6 minutes, and then plug unit back in.  
If light is still red, refer to "Requesting Assistance or Service.”  
Operation/Status light  
lights red  
(on some models)  
If Operation/Status light repeatedly lights red, refer to “Requesting Assistance  
or Service.”  
• Check to see if unit is securely plugged into an electric outlet.  
• Check to see if operation light is illuminated when blender is On.  
Unit will not run  
• Check to see if the fuse for the electric outlet has blown or if a circuit breaker  
has tripped.  
• Jar is not securely seated on the base.  
Ingredients will not mix • Check to see if enough liquid has been added to the ingredients. Mixture should  
properly  
be fluid and free-running at all times.  
• Solid pieces are too large. Pieces should not exceed 1cubes.  
• Jar is too full. Do not fill past highest graduation marking.  
• Cutters are not sharp or are damaged. Inspect jar and cutter assembly daily.  
Replace jar and cutter assembly at least every 12 months or when damaged.  
Operation/Status light  
lights yellow  
(on some models)  
• Jar is not on blender base.  
• Jar is not securely seated on optional jar pad sensors.  
Maintenance  
Inspect the blender and its various parts and replace as follows:  
Unplug the blender and remove the jar from the base, and then inspect the jar and cutter assembly  
for wear, nicks, or broken blades. Replace if necessary. See “Replacement Parts” below.  
Daily  
Unplug the blender, and then inspect the power cord insulation and power plug for cracks. Refer to  
“Requesting Assistance or Service” for repair or replacement.  
Weekly  
Yearly  
Replace the jar and cutter assembly at least once a year. See “Replacement Parts” below.  
NOTE: Do not operate this blender if it malfunctions or is dropped or damaged in any manner. Return blender to  
the nearest authorized service facility for examination, repair, or electrical or mechanical adjustment.  
Replacement Parts  
Refer to “Requesting Assistance or Service” on page 2 to order parts below.  
Description . . .  
Part Number . . .  
6126-91515  
32 oz. Polycarbonate jar and cutter assembly (includes cover/filler cap)  
5
Product Warranty  
This Warranty supercedes all other Product Warranties  
This product is warranted to be free from defects in material and workmanship for a period of three (3)  
years parts/ two (2) years labor OR 15,000 cycles (whichever comes first) from the date of original pur-  
chase, except as noted below. There is a lifetime warranty on the motor drive coupling and blade.  
During this period, we will repair or replace this product, at our option, at no cost to you.  
THE FOREGOING WARRANTY IS IN LIEU OF ANY OTHER WARRANTY, WHETHER EXPRESSED OR  
IMPLIED, WRITTEN OR ORAL INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS  
FOR A PARTICULAR PURPOSE. ANY LIABILITY IS EXPRESSLY LIMITED TO AN AMOUNT EQUAL TO  
THE PURCHASE PRICE PAID, AND ALL CLAIMS FOR SPECIAL, INCIDENTAL, AND CONSEQUENTIAL  
DAMAGES ARE HEREBY EXCLUDED.  
There is no warranty with respect to the following, which may be supplied with this product: (motor brushes,  
container and cutter assembly, container clutches, bristle brushes, funnel, stainless steel cup, agitators,  
carafes, etc.). This warranty extends only to the original purchaser and does not cover a defect resulting  
from abuse, misuse, neglect, unauthorized repair, or any use not in conformity with the printed directions.  
Always use this product in the manner provided in the Operation Manual. This warranty gives you specific  
legal rights, and you may also have other legal rights which vary from state to state or province to province.  
Some states do not allow limitations on implied warranties or special, incidental or consequential damages,  
so the foregoing limitations may not apply to you.  
If you have a claim under this warranty, please contact our TECHNICAL SERVICE CENTER  
1-866-285-1087. (For faster service, please have model, series, and type numbers ready for the  
operator to assist you). Reasonable proof of the date of purchase must be presented; otherwise,  
the effective date of the warranty will be based on the date of manufacture plus ninety days.  
Hamilton Beach/Proctor-Silex, Inc.  
Commercial Customer Service  
263 Yadkin Road  
Southern Pines, NC 28387  
01/03  
6

Black Box Cable Box ME758C RJ45 User Manual
Black Decker Bl2010WP User Manual
Bunn O MATIC ULTRA 1 User Manual
Casio s v p a m fx 350MS User Manual
Cecilware B4S 120 User Manual
DXG Technology DXG 202V User Manual
Eclipse Fujitsu Ten CD3434 User Manual
Gitzo G1258 User Manual
JVC Camcorder GY DV500 User Manual
JVC GR SXM770A User Manual