Cleveland Range GFB 6 User Manual

Project ________________________________  
Item __________________________________  
Quantity _______________________________  
FCSI Section ____________________________  
Approval _______________________________  
Date __________________________________  
Cleveland  
COOK CHILL SYSTEMS  
Cook/Chill Systems  
MODELS:  
GFB-6  
GFB-10  
GFB-15  
GFB-20  
GFB-30  
GFB-50  
GFB-60  
GAS FIRED STEAM BOILERS  
Cleveland Standard Features  
I Complete skid-mounted and piped, gas fired Steam Boiler with  
Vertical Return System and Blow Down Separator  
I Available for Pressure Ratings from 15 to 150 psi (specify  
required operating pressure)  
I Vertical Tubeless design  
I Fully insulated Boiler with top mounted, down-fired burners  
I High Temperature Insulation assists thermal efficiency of 80%  
I Spinning Cyclonic Flame travels down the entire length of the  
Combustion Chamber  
I Top Flame Retainer increases occupancy time of flue gases to  
complete combustion process  
I Operating Pressure Control and High Limit Pressure Control  
with Manual Reset  
I Water Column with Water Gauge Assembly  
I All necessary valves are included  
I Automatic Water Feed System with probe type Water Level  
Controls and single phase Motor for Pump  
I Steam Outlet conveniently located at top of Boiler  
I Control Panel factory mounted and wired, ready for power con-  
nection  
I Built and stamped to A.S.M.E. Code  
I Registered with the National Board of Boiler & Pressure Vessel  
Inspectors  
Short Form Specifications  
I Accepted for use in U.S.D.A. Inspected Facilities  
Shall be CLEVELAND Model GFB -____, gas-fired, vertical, tube-  
less LARGE STEAM BOILER System, _____H.P. (horse power);  
Complete with Power Burners; Skid mounted and piped with  
Vertical Condensate Return System and Blow-Down Separator  
Package; Factory assembled as a self-contained unit, in accor-  
dance to U.L. requirements, and A.S.M.E. Section 1 (one) Code;  
Guaranteed production of _______ pounds of Steam per hour at  
212˚F.  
Options & Accessories  
Ë Stainless Steel outer Jacket  
Ë Automatic Boiler Blow-down Controls  
Ë Applicable Controls to meet the various special insurance,  
local, state or federal code requirements  
Ë Electric heated Steam Boilers  
Ë Oil-fired Steam Boilers  
Ë Cooling Kit for boiler drain  
Ë Aquastat automatic drain cooling kit  
Ë Larger models availabe on request  
SECT. XIV PAGE 53  
0907  
1333 East 179 St.,  
Tel: 1-216-481-4900  
Fax: 1-216-481-3782  
Cleveland, Ohio, U.S.A. 44110  

Addonics Technologies DGBRC1 User Manual
Bazooka MAA500 1 User Manual
Bogen Communications Car Speaker WB1EZ User Manual
Canon Camcorder Vixia HD Camcorder User Manual
Directed Electronics s650 User Manual
Gateway FHD2102 User Manual
Hypertec N10938PHY User Manual
Hyundai H CMD7075 User Manual
JVC GR AX890UC User Manual
JVC GR PD1 User Manual