FlexCam iCam — Introduction  
2
FlexCam iCam — Introduction  
Important safeguards  
Unpacking  
Before operating the FlexCam iCam, please read the entire manual thoroughly.The FlexCam  
iCam was designed, built and tested for use indoors.The use of a power supply other than the  
one provided or outdoor operation has not been tested and could damage the camera or  
peripheral equipment and/or create a potentially unsafe operating condition.  
Carefully remove the FlexCam iCam unit, cables and power supply from the packaging.  
Ensure that you received the following parts:  
Do not operate the FlexCam iCam if the power cord is damaged or if the camera has been  
dropped or damaged. A qualified service technician must examine the FlexCam iCam  
before operating.  
Position the cord so that it will not be tripped over, pulled on or come into contact with hot  
surfaces.  
Always unplug the FlexCam iCam from the electrical outlet before cleaning or servicing.  
To reduce the risk of electric shock, do not immerse in water or other liquid.  
FlexCam iCam  
Plug  
12 VDC Power Supply  
12' S-video cable  
Use only the power supply provided with the FlexCam iCam. Use of any unauthorized power  
supply will void any and all warranties.  
!
Handling the camera  
All ClearOne cameras are for indoor use only.  
Microscope Couplers  
26 mm, 28 mm and  
34 mm  
S-video to composite adapter  
FlexCam iCam  
Manual  
Do not use cameras next to food or beverages. Cameras have been tested and approved for  
use in chemistry labs. However, be very careful not to spill liquid or dry chemicals or  
solvents on the camera.  
Figure 1. FlexCam iCam and accessories  
Do not use cameras right next to working TVs, radios, motors, transformers or magnetic  
fields.  
ClearOne is not responsible for product damage incurred during shipment.You must make  
claims directly with the carrier. Inspect your shipment carefully for obvious signs of  
damage. If the shipment appears damaged, retain the original boxes and packing material for  
inspection by the carrier. Contact your carrier immediately.  
Avoid touching the lens.To clear any dust, blow pressurized air onto the lens. For  
accidental smears or smudges, wipe carefully with a lens cleaning cloth.  
Clean exterior of camera by wiping with a clean, damp cloth; do not use any abrasive  
chemicals.  
Use both hands whenever adjusting the neck of the camera; this will avoid any unnecessary  
strain on the camera’s base and will keep the camera from tipping over unexpectedly.  
Do not attempt to take the camera apart. There are no user-serviceable components inside.  
Do not direct the lens of the camera toward the sun. This may damage the camera.  
Operating and storage conditions  
Do not store or operate the camera under the following conditions:  
Outdoors or connected to outdoor or auxiliary power sources.  
In environments with high humidity.  
In inclement weather.  
Under severe vibration.  
Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760  
Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760  
5
FlexCam iCam — Introduction  
4
FlexCam iCam — Introduction  
Product overview  
FlexCam iCam application examples  
The FlexCam iCam easily connects to a variety of display devices allowing many different  
uses in the classroom. You can display presentations, student work or slides on a TV or pro-  
jector or use the microscope and optional couplers and eyepiece to share lab work and view  
microscopic organisms. Using a USB adapter or a video capture card,you can connect the  
camera to a computer to add video or photos to a web site and enhance presentations.  
C
D
A
S-video  
Microscope  
B
TV or Video Monitor  
FlexCam iCam  
S-video  
Figure 2. FlexCam iCam overview  
USB  
A. Gooseneck.The gooseneck allows you to adjust the camera head/camera lens over the  
object to be viewed. Do not bend the gooseneck more than 90° in any direction or attempt  
to tie it in a knot. Do not attempt to repair any cracks in the vinyl coating.The gooseneck  
is nondetachable and should be replaced only by ClearOne.  
PC or Mac  
USB Adapter  
FlexCam iCam  
B. Camera base.The camera base has five rubber feet for non-slip support of the camera.  
C. Camera head.The head of the camera unit contains the camera lens, lens holder, focus ring  
attachments, connections to gooseneck and all cables.  
S-video  
D. Camera lens and lens holder.The camera lens is held in place by the lens holder. Both are  
permanently attached to the camera head. If you unscrew the lens, take care not to  
cross thread the lens when putting it back.  
LCD Projector  
FlexCam iCam  
S-video  
Composite  
S-video to  
composite adapter  
FlexCam iCam  
VCR  
Figure 3. FlexCam iCam Applications  
Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760  
Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760  
7
FlexCam iCam — Making Connections  
6
FlexCam iCam — Using the Camera  
Using the Camera  
Making Connections  
To view images on a TV  
1. Connect the camera to a TV using the S-video cable or composite adapter.  
You can connect the FlexCam iCam to a TV, VCR or LCD projector using the included 12'  
S-video cable. If your video supply device requires a composite signal, use the provided  
S-video to composite adapter.  
2. Switch the TV to video mode by using the switch on the TV front panel or pressing the  
corresponding button on the remote control (consult your owner's manual for further  
instructions).  
You can also connect the FlexCam iCam to a PC or Macintosh using the S-video to USB  
Adapter (ClearOne part number 911-171-100).  
Note: Not all TVs have video inputs. If your TV only has an antenna input, you will need  
a modulator or a VCR with video inputs.  
To connect to a TV,VCR or projector  
1. Connect the S-Video output of the FlexCam iCam to the input of the display device.  
If needed, use the S-video to composite video adapter.  
3. Turn camera on using the on/off switch located at the base of the gooseneck.  
4. Adjust the flexible gooseneck until the camera is aligned with the subject.  
5. Turn the focus ring to the left for close-up or right for distance.  
2. Connect the power plug to the power jack on the back of the Flex Cam iCam.  
3. Plug the power adapter into the wall.  
To record images on a VCR  
1. Connect the camera to a VCR using the S-video cable or composite adapter.  
2. Switch the VCR to the video-in mode (consult your owner’s manual for instructions).  
3. Turn camera on using the on/off switch located at the base of the gooseneck.  
4. Turn the VCR/TV switch to VCR and the TV to either channel 3 or 4.  
5. Adjust the flexible gooseneck until the camera is aligned with the subject.  
6. Turn the focus ring to the left for close-up or right for distance.  
7. Press record on the VCR.  
Power  
adapter  
Composite adapter  
if required  
S-video  
Video display  
FlexCam iCam  
To view images on a LCD projector  
1. Connect the camera to a projector using the S-video cable or composite adapter.  
2. Turn the projector on (consult your owner’s manual for further instructions).  
3. Turn camera on using the on/off switch located at the base of the gooseneck.  
4. Adjust the flexible gooseneck until the camera is aligned with the subject.  
5. Turn the focus ring to the left for close-up or right for distance.  
Figure 4. Connections to a display device  
To connect to a computer  
If your computer has a video capture card, plug the S-video cable into the card. Refer to  
the video capture card manual for more information.  
or  
To use the microscope couplers  
If your computer does not have a video capture card, you will need to purchase the USB  
Adapter. Refer to the USB Adapter manual for more information.  
Depending on the size of your microscope (28 mm and 34 mm), attach the correct coupler  
to the microscope by placing it over the microscope’s original eyepiece.  
Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760  
Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760  
9
FlexCam iCam Troubleshooting  
8
FlexCam iCam — Appendix  
Troubleshooting  
Appendix  
If you are experiencing problems with your camera:  
Specifications  
Video Output  
S-video and composite  
Gooseneck  
20"/50.8 cm  
Ensure all camera adapter/cable connections and electrical connections are done correctly  
and completely.  
Video Format  
910-171-101 NTSC  
Check your computer, video capture cards, digitizer boards,VCR,TV, etc., for faulty  
operation.  
Weight  
4 lb/1.81 kg  
910-171-101 PAL  
Check all settings on your camera and adjust them for viewing conditions in the  
presentation room.  
Power Supply  
12 VDC  
Exterior Color  
Translucent blueberry with black accents  
If any component of any camera is damaged, contact ClearOne Technical Support for repair  
information.  
Operating Temperature  
32º F – 104º F/0º C – 40º C  
Included Accessories  
12' (3.65 m) S-video cable  
S-video to RCA adapter  
SCART adapter (PAL models)  
Microscope couplers  
Image Sensor  
1
/
3
" (8.5 mm) CMOS  
No. of Effective Pixels  
Optional Accessories  
910-171-320 FlexLiteTM  
508(H) x 492(V), 251K pixels NTSC  
628(H) x 582(V), 365K pixels PAL  
910-171-100 USB adapter  
910-171-327 Microscope eyepiece adapter  
Resolution  
330 TV lines (horizontal)  
Focus Range  
1
/
4" (6.35 mm) to infinity  
Lens  
8 mm (.32") D-mount glass lens  
Gain Control  
Auto  
White Balance  
Auto  
Iris  
Auto, electronic with flicker-free  
performance  
Sensitivity  
3 lux  
S/N Ratio  
>4 adB  
Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760  
Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760  
11  
FlexCam iCam — Appendix  
10  
FlexCam iCam — Appendix  
Optional accessories  
Contact your ClearOne reseller for more information on the following accessories.  
Warranty  
ClearOne Communications, Inc. (Manufacturer) warrants that this product is free of defects in both  
materials and workmanship. Should any part of this product be defective, the Manufacturer agrees,  
at its option, to:  
FlexLite™  
Repair or replace any defective part free of charge (except transportation charges) for a period of  
two years from the date the end user is invoiced for the product, provided the end user returns the  
product to ClearOne Communications or an authorized ClearOne dealer according to the Product  
Return and Repair statement set forth below;  
The FlexLiteis designed for use with any flexible camera. Dual flexneck top lights attach to  
the base of your FlexCam to provide adequate lighting for all subjects. Available in 110 V  
(NTSC) and 220 V (PAL) versions.  
This warranty excludes assembled products not manufactured by the Manufacturer whether or not  
they are incorporated in a Manufacturer product or sold under a Manufacturer part or model  
number.  
USB adapter  
Use the USB adapter for Internet videoconferencing, motion video capture, still frame  
capture and video editing.  
Product Return and Repair  
1. Return to Seller if Purchased Through an Authorized Dealer  
a.Proof of purchase date from reseller within warranty period must be provided by the end user.  
b. Seller may, at its discretion, provide an immediate exchange or repair or may return the unit to  
the Manufacturer for repair.  
Microscope eyepiece adapter  
Create a firm connection between your camera and microscope with the microscope eyepiece  
adapter. Remove the original eyepiece of the microscope and replace with this adapter for a  
tighter fit between camera and microscope.  
2. Return to Manufacturer  
a.An RMA (return merchandise authorization) number must be issued to the end user from  
ClearOne technical support.  
b. The end user must return the product to ClearOne with proof of purchase (showing purchase  
date) for a warranty claim, and display the RMA number on the outside of the shipping package.  
To attach the microscope adapter  
1. Remove the microscope eyepiece.  
This warranty is void if:  
A. The product has been damaged by negligence, accident, act of God, or mishandling, or has not  
been operated in accordance with the procedures described in the operating and technical  
instructions; or,  
2. Replace the original eyepiece with the custom eyepiece adapter by sliding the narrow end  
into place on the microscope.  
B. The product has been altered or repaired by other than the Manufacturer or an authorized  
service representative of the Manufacturer; or,  
C. Adaptations or accessories other than those manufactured or provided by the Manufacturer have  
been made or attached to the product which, in the determination of the Manufacturer, shall have  
affected the performance, safety or reliability of the product; or,  
D. The product's original serial number has been modified or removed.  
NO OTHER WARRANTY, EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MER-  
CHANTABILITY OR FITNESS FOR ANY PARTICULAR USE, APPLIES TO THE PRODUCT.  
MANUFACTURER'S MAXIMUM LIABILITY HEREUNDER SHALL BE THE AMOUNT PAID  
BY THE END USER FOR THE PRODUCT. No person or entity authorized to assume any obligation  
or other liability in connection with the products. No action, regardless of form, arising out of or  
relating to the product or this warranty, may be brought by end user more than two (2) years after  
the cause of action has accrued.  
Eyepiece adapter  
Connection to the camera  
Original eyepiece  
Figure 5. Optional eyepiece attachment  
3. Gently push the camera into position.  
Manufacturer shall not be liable for punitive, consequential, or incidental damages, expenses, or loss  
of revenue or property, inconvenience, or interruption in operation experienced by the end user due to  
a malfunction in the purchased product. No warranty service performed on any product shall extend  
the applicable warranty period.  
Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760  
Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760  
13  
FlexCam iCam — Appendix  
12  
FlexCam iCam — Appendix  
Standard(s) to which Conformity is declared:  
In case of unsatisfactory operation, the end user shall promptly notify the Manufacturer at the  
address set forth below in writing, giving full particulars as to the defects or unsatisfactory  
operation. Upon receipt of such notice, the Manufacturer will give instructions respecting the  
shipment of the product, or such other matters as it elects to honor this warranty as above provided.  
This warranty does not cover damage to the product during shipping and the Manufacturer assumes  
no responsibility for such damage. All shipping costs shall be paid by the customer.  
89/336/EEC "Electromagnetic Compatibility (EMC) Directive":  
EN 55022: 1994 (Emissions)  
Specification for limits and methods of measurement of  
radio interference characteristics of information  
technology equipment  
EN 61000-3-2:1995/A1/A2:1998  
EN 61000-3-3:1995  
Part 3: Limits - Section 2: Limits for harmonic  
current emissions.  
This warranty extends only to the original end user and is not assignable or transferable.This  
warranty is governed by the laws of the State of Utah, without regard to the conflicts of interests  
provisions thereof.  
Section 3: Limitation of voltage fluctuations and  
flicker in low voltage supply systems for equipment  
with rated current up to and including 16 A  
ClearOne Communications Inc.  
1825 Research Way  
EN 55024: 1998 (Immunity)  
Information technology equipment -Immunity  
characteristics - Limits and methods of  
measurement  
Salt Lake City, Utah 84119  
EN 61000-4-2: 1995/A1:1998  
EN 61000-4-3: 1996/A1:1998  
EN 61000-4-4: 1995  
Electrostatic Discharge  
Radiated RF Immunity  
Electrical Fast Transients  
Lighting Surge  
FCC Part 15/ICES-003 Compliance  
This equipment has been tested and found to comply with the limits for a Class A digital device,  
pursuant to Part 15 of the FCC rules and Industry Canada ICES-003.These limits are designed to  
provide reasonable protection against harmful interference when the equipment is operated in a  
commercial environment.This equipment generates, uses, and can radiate radio frequency energy and,  
if not installed and used in accordance with the instruction manual, may cause harmful  
interference to radio communications. Operation of this equipment in a residential area is likely to  
cause harmful interference, in which case the user will be required to correct the interference at  
his/her own expense.  
EN 61000-4-5: 1995  
EN 61000-4-6: 1996  
Conducted RF Immunity  
Voltage Dips and Voltage Interruptions  
EN 61000-4-11: 1994  
73/23/EEC "Low Voltage Directive (LVD)":  
IEC 60950-1: 2003  
Safety of Information Technology Equipment,  
Including Electrical Business Equipment  
Operation is subject to the following two conditions: (1) This device may not cause interference, and  
(2) This device must accept any interference including interference that may cause undesired  
operation of the device.  
We, the undersigned, hereby declare that the equipment specified above conforms to the above  
Directives and Standards.  
Changes or modifications not expressly approved by ClearOne Communications could void the user's  
authority to operate the equipment.  
Manufacturer  
Legal Representative in Europe  
European Compliance  
This equipment has been approved in accordance with Council Directive 1999/5/EC "Radio  
Equipment and Telecommunications Equipment". Compliance of the equipment with the Directive is  
attested by the application of the CE mark on the equipment.  
EC Declaration of Conformity  
Signature  
Signature  
Application of Council Directive(s):  
1999/5/EC Radio equipment and  
Telecommunications Terminal Equipment  
(R&TTE) Directive  
Roger J. Midgley  
Full Name  
Martin Offwood  
Full Name  
Project Manager  
Position  
Managing Director EMEA North  
Position  
Manufacturer's Name:  
Manufacturer's Address:  
ClearOne Communications  
1825 West Research Way Salt Lake City,  
Utah 84119 U.S.A.  
Model No.:  
FlexCam iCam 910-171-101-PAL  
FlexCam iCam Digital 910-171-102-PAL  
Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760  
Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760  

BeachTek DXA 4P User Manual
Behringer Professional 600 Watt Reference Class Studio Power Amplifier A500 User Manual
Black Decker BLP6601MUC User Manual
Canon XH G1 User Manual
Cerwin Vega stroker Pro 15 User Manual
Crown Boiler CWI345 User Manual
Deni Giovanna Italy 4400 User Manual
Epson Camera Accessories 750Z User Manual
Fusion Electronics Car Amplifier CA AM20350 User Manual
JVC GR DX317 User Manual