Burnham Minuteman II User Manual

Minuteman® II Gas-Fired Boiler  
I=B=R  
NET  
WATER  
RATING  
MBH  
DOMESTIC  
HOT WATER  
100° RISE  
INTERMITTENT  
DRAW  
MAXIMUM  
AIR  
INLET  
LENGTH  
EQUIV. FT.  
(4) (5)  
MAXIMUM  
VENT  
LENGTH  
EQUIV. FT.  
(4) (5)  
AGA  
INPUT  
MBH  
(2)  
DOE  
HEATING  
CAPACITY  
MBH  
APPROX.  
SHIPPING  
WEIGHT  
(LBS.)  
BOILER  
NUMBER  
(1)  
(3)  
GPM  
AFUE%  
MMII 4-70  
MMII 4-105  
MMII 5-105  
MMII 5-140  
70  
58  
84  
88  
50  
73  
77  
97  
2.9  
3.1  
3.1  
3.3  
70  
70  
70  
70  
70  
70  
70  
70  
83.3  
80.2  
83.3  
80.1  
307  
307  
345  
345  
105  
105  
140  
112  
1.  
2.  
If LP gas specify on order. Ratings are the same.  
AGA Ratings shown are for installations at sea level and elevations up to 2,000 ft. For eleva  
tions above 2,000 ft. A.G.A. ratings should be reduced at the rate of four percent (4%) for  
each 1,000 ft. above sea level.  
3.  
Net I=B=R ratings shown are based on normal I=B=R piping and pick-up allowance of 1.15.  
Consult the manufacturer for installations having unusual piping and pick-up requirements  
such as intermittent system operation, extensive piping systems, etc.  
4.  
5.  
Maximum equivalent length cannot exceed the sum of the length of straight pipe and the  
equivalent length of any elbow used (90° and 45° elbows equal 5 equivalent feet).  
The direct vent Minuteman II is designed to vent directly through the wall using Burnham's  
approved vent system, 3" AL29-4C® stainless steel pipe. Inlet air can be supplied using 4" 26  
gauge galvanized or similar.  
Working Pressure: 30 PSI  

BEST Range Hoods K260A User Manual
Black Decker BlP6601M User Manual
Canon Camcorder D200 User Manual
Cuisinart CBT 500 Series User Manual
Hitachi DZMV580A User Manual
HP (Hewlett Packard) Hewlett Packard Camcorder M425 User Manual
HP (Hewlett Packard) Photosmart 6220 User Manual
JBL MR 17 User Manual
JL Audio C2 600 User Manual
JVC BN V856 User Manual