Form No. 1930
(04/05)
Bryan “Flexible Water Tube”
CLM Series
Steam & Water Boilers
1,200,000 to 3,000,000 BTUH
Forced draft gas, oil or dual fuel fired
Steam Boiler
CLM-180-S150-FDGO
Water Boiler
CLM-300-W-FDG
®
BRYAN BOILERS
Originators of the “Flexible Water Tube” design
Low initial cost, high operating efficiency
deliver substantial return on investment
• True “flexible water tube”
design guaranteed shock free
G
• Longer service life with
superior performance
I
• Full five sq ft of heating
L
surface per BHP
Quality Construction Features
A. Heavy steel boiler frame, built and stamped in accor-
dance with the appropriate ASME Boiler Code.
B
J
C
B. Large volume water leg downcomers promote rapid
internalcirculation,temperatureequalizationandefficient
heattransfer.
D
E
K
C. Bryan bent water tubes are flexible, individually re-
placeablewithoutweldingorrolling.Nevermorethantwo
tubeconfigurations.
F
A
D. Boiler tube and furnace area access panel: heavy
gaugesteelcasingwith2"hightemperatureceramicfiber
and insulation, bolted and tightly sealed to boiler frame.
E. Jacket access panels make the interior of the boiler
easily accessible for service and inspection.
H
M
F.Heavygaugesteelboilerjacketwithrust-resistantzinc
coating and attractive enamel finish, insulated with 1½"
fiberglass to insure exceptionally cool outer surface.
G. Minimum sized flue vent.
H. Forced draft, flame retention head type burner. Effi-
andinspection,frontandrearopenings,upperandlower
drums.
cient combustion of oil or gas, quiet operation.
I.Allcontrols, gauges, reliefvalve(s)arefactoryinstalled
and wired and easily accessible for servicing.
L. Steam boilers with extra large drum with high steam
release area ensure stable water level and dry steam.
J. Electrical box: all controls installed and connected to
terminalstrip.
M.Steelplateboilerbasewithlightweight,hightempera-
ture insulating firebrick combustion chamber, designed
formaximumcombustionefficiency.
K.Watersideorsteamsideinterioraccessibleforcleanout
Bryan CLM Series Boilers Standard and Optional Equipment
Hotwaterboiler
STANDARD EQUIPMENT FURNISHED
OPTIONAL EQUIPMENT:
OptionalconstructiontoASMEPower
BoilerCoderequirementsfortempera-
turesexceeding240°Fand/orpressure
exceeding160psitomaximumof285°
Foperatingand300°F designtempera-
ture and 250 psi.
1. Manual reset high limit control
2. Manual reset low water cutoff
3. Auxiliary low water cutoff
4. Combinationlowwatercutoff
andfeeder
WaterBoiler
switch, control panel, all controls in-
stalledandwired.
Combinationthermometerandpres-
sure gauge, ASME-rated boiler relief
valve,watertemperaturecontrol(240°F
max std.), high limit control, probe
LWCO.
Straight oil fired unit
Electroniccombustionsafetycontrol,
dualoilvalves,oilignitiontransformer,
two-stage fuel unit, direct spark
ignition of oil, oil nozzle assembly,
control panel, all controls installed
andwired.
5. Alarm bells or horns
6. UL, CUL, CSD-1, FM, IRI or
otherinsur-anceapproved
controlsystems
Whenordering,pleasespecify:
1. Boilersize
2. Supplyandreturntempera-
turesrequired
SteamBoiler
7. Controlpanelmountedonboiler
8. Indicatinglights, asdesired
9. Lead-lag systems for two or
moreboilerswithorwithout
outdoorresetcontrol
Steam pressure gauge, steam pres-
sure control, combination low water
cutoffandpumpcontrol,auxiliarylow
watercutoff, highlimitpressurecon-
trol, ASME-rated boiler relief valve,
water glass set.
3. Boilerreliefvalvesetting
4. Type of fuel: natural, LP, or
other gas and/or No. 2 oil
5. If gas, type, BTU content,
specificgravityandpressure
available
Combination gas-oil unit
Electroniccombustionsafetycontrol,
automaticoperatinggasvalve,safety
gas valve, pilot solenoid valve, pilot
ignition assembly, main manual gas
shut-off valve, pilot cock, pilot and
main gas pressure regulators, air
safety switch, manual fuel selector
switch, dual oil valves, gas pilot for
bothfuels, two-stagefuelunit, nozzle
assembly, control panel, all controls
installedandwired.
10. Draftcontrolsystem
11. Specialconstruction:lefthand,
KnockedDown.
Straight gas fired unit
6. Electricpowervoltage, phase
andfrequency
Electroniccombustionsafetycontrol,
automaticoperatinggasvalve,safety
gas valve, pilot solenoid valve, pilot
ignition assembly, main manual gas
shut-off valve, pilot cock, pilot and
maingaspressureregulators,airsafety
OPTIONAL CONSTRUCTION:
Steamboiler
OptionalconstructiontoASMEPower
BoilerCoderequirementsforpressure
exceeding150psitomaximumof300
psidesignpressure.
7. Optionalextraequipmentor
construction
8. Specialapprovalsrequired
(UL, CUL, CSD-1, FM, or IRI)
9. Altitude
Bryan CLM Series Steam & Hot Water Boilers
D
A
B
K
J
K
C
H
PLAN VIEW
LEFT END VIEW
FRONT VIEW
RIGHT END VIEW
STEAM BOILER DIMENSIONS in inches (cm)
A
B
C
D
E
F
G
H
I
J
K
Supply
Boiler
Model
Length
Gas Train
Connection
(Approx.)
Width
Outside
Jacket
Min. Tube
Height
Floor to
Flue
Flue
Size
Overall
Length
Feed
Nozzle
of
Removal
Over
Flow
Location
Conn.
Number
Jacket
Clearance
Jacket
Nozzle
15 psi
150 psi
5011/16
2511/32
10
7811/16
11/4 NPT
(3.18)
6 FLG
(15.24)
3 NPT
(7.62)
11/2 NPT
(3.81)
383/8
30
(76.2)
30
(76.2)
30
(76.2)
30
(76.2)
30
(76.2)
30
(76.2)
30
(76.2)
797/16
825/8
CLM-120-S
(128.74) (64.37) (25.40) (199.86)
(97.47)
(201.76)
(209.86)
5911/16
2927/32
12
8711/16
11/2 NPT
(3.81)
6 FLG
(15.24)
3 NPT
(7.62)
11/2 NPT
(3.81)
383/8
797/16
825/8
CLM-150-S
CLM-180-S
CLM-210-S
CLM-240-S
CLM-270-S
CLM-300-S
(151.60) (75.80) (30.48) (222.72)
(97.47)
(201.76)
(209.86)
691/8
349/16
14
971/8
2 NPT
(5.08)
2 NPT
(5.08)
2 NPT
(5.08)
6 FLG
(15.24)
3 NPT
(7.62)
11/2 NPT
(3.81)
383/8
797/16
825/8
(175.57) (87.78) (35.56) (246.69)
(97.47)
(201.76)
(209.86)
783/8
393/16
14
1063/8
6 FLG
(15.24)
3 NPT
(7.62)
11/2 NPT
(3.81)
383/8
797/16
825/8
(199.07) (99.53) (35.56) (270.19)
(97.47)
(201.76)
(209.86)
88
(223.52) (111.76) (40.64) (294.64)
97 16 125
481/2
44
16
116
6 FLG
(15.24)
3 NPT
(7.62)
11/2 NPT
(3.81)
383/8
797/16
825/8
(97.47)
(201.76)
(209.86)
2 NPT
(5.08)
6 FLG
(15.24)
3 NPT
(7.62)
11/2 NPT
(3.81)
383/8
797/16
825/8
(246.38) (123.19) (40.64) (317.50)
(97.47)
(201.76)
(209.86)
1065/8
533/16
16
1345/8
21/2 NPT
(6.35)
6 FLG
(15.24)
3 NPT
(7.62)
11/2 NPT
(3.81)
383/8
797/16
825/8
(270.82) (135.41) (40.64) (341.94)
(97.47)
(201.76)
(209.86)
D
A
I
L
C
B
H
E
J
G
F
K
P
L
A
N
V
I
W
R
E
A
R
V
I
W
L
E
F
T
S
I
E
V
I
W
F
R
O
N
T
V
I
W
WATER BOILER DIMENSIONS in inches (cm)
A
B
C
D
E
F
G
H
I
J
K
Boiler
Model
Length
of
Gas
Train
Width
Outside
Jacket
Min. Tube
Removal
Height
Over
Floor to
Flow
Flue
Flue
Size
Overall
Length
Supply
Nozzle
Return
Nozzle
Location
Number
Jacket
Connection
Clearance Jacket
Nozzle
5011/16
255/16
10
7811/16
11/4 NPT
(3.18)
11/2 NPT
(3.81)
2 NPT
(5.08)
2 NPT
(5.08)
2 NPT
(5.08)
2 NPT
(5.08)
21/2 NPT
(6.35)
3 NPT
(7.62)
3 NPT
(7.62)
3 NPT
(7.62)
3 NPT
(7.62)
3 NPT
(7.62)
3 NPT
(7.62)
3 NPT
(7.62)
3 NPT
(7.62)
3 NPT
(7.62)
3 NPT
(7.62)
3 NPT
(7.62)
3 NPT
(7.62)
3 NPT
(7.62)
3 NPT
(7.62)
345/8
30
(76.2)
30
(76.2)
30
(76.2)
30
(76.2)
30
(76.2)
30
(76.2)
30
(76.2)
721/16
763/16
CLM-120-W
CLM-150-W
CLM-180-W
CLM-210-W
CLM-240-W
CLM-270-W
CLM-300-W
(128.74)
(64.29)
(25.40) (199.86)
(87.94)
(180.03) (193.51)
5911/16
2913/16
(75.72)
12
(30.48) (212.72)
14
971/8
(35.56) (246.69)
14
1063/8
(35.56) (270.19)
16 116
(40.64) (294.64)
16 125
(40.64) (317.50)
16
1345/8
(40.64) (341.91)
8711/16
345/8
721/16
763/16
(151.60)
(87.94)
(180.03) (193.51)
691/8
349/16
345/8
721/16
763/16
(175.57)
(87.78)
(87.94)
(180.03) (193.51)
783/8
393/16
345/8
721/16
763/16
(199.07)
(99.53)
(87.94)
(180.03) (193.51)
88
44
345/8
721/16
763/16
(223.52) (111.76)
(87.94)
(180.03) (193.51)
97
(246.38) (123.19)
1065/8
(270.82) (135.41)
481/2
345/8
721/16
763/16
(87.94)
(180.03) (193.51)
533/16
345/8
721/16
763/16
(87.94)
(180.03) (193.51)
Specifications subject to change without notice. Consult factory to consult on other boiler options.
BryanSteamLLC— LeadersSince1916
783 N. Chili Ave., Peru, Indiana 46970 U.S.A.
Phone:765-473-6651
Fax: 765-473-3074
•
Internet:www.bryanboilers.com
•
Form No. 1930
©2005 Bryan Steam LLC
Printed in USA
45-6832
|