Baxi Potterton Promax Combi 24 HE Plus A User Manual

You can rely on  
User Guide and  
Promax Combi  
Important Warranty Information  
HE Plus A  
Range  
Condensing  
Combination Boiler  
Please keep these instructions in a safe place.  
If you move house, please hand them over to  
the next occupier.  
© Baxi Heating UK Ltd 2012  
1.0 Quick Reference Guide  
2
Reset  
1
3
0
4
bar  
ON/OFF/Reset  
Selector Switch  
Display  
Central Heating  
Temperature Control  
Domestic Hot Water  
Temperature Control  
System Pressure Gauge  
Position of  
Optional Timer  
Reset  
Reset  
Reset  
Reset  
OFF Position  
The boiler will not operate.  
Central Heating & Hot Water  
Both Heating & Hot Water will operate.  
Domestic Hot Water  
Hot Water will operate.  
Reset  
Hold for approx 5 seconds and release.  
Central Heating Indicator - The indicator will illuminate when the boiler is in the central  
heating mode.  
Domestic Hot Water Indicator - The indicator will illuminate when hot water is being  
supplied to a tap or shower.  
Burner On Indicator - The indicator will illuminate when the burner has fired and is heating  
your central heating or domestic hot water.  
Boiler Output Temperature - In either the central heating or domestic hot water position  
the display will illuminate showing the current boiler temperature in degrees centigrade.  
Display  
Central Heating Temperature Control  
Turn the knob clockwise to increase or anticlockwise to decrease the temperature.  
Range 25 - 80° C.  
Domestic Hot Water Temperature Control  
Turn the knob clockwise to increase or anticlockwise to decrease the temperature.  
Range 35 - 60° C.  
2
Central Heating System Pressure - The normal operating water pressure is shown when the  
needle is in the GREEN section of the gauge, between 1 and 2.5 bar. If the pressure exceeds 3  
bar (needle in the RED section) the safety pressure valve will operate and a fault is indicated.  
Contact your Installer.  
1
3
0
4
bar  
3
© Baxi Heating UK Ltd 2012  
Boiler not working  
2.0 Troubleshooting  
START  
Make sure the gas supply is  
turned ON and check if other  
gas appliances are operating  
(e.g. fire, cooker).  
Is the (  
and the (  
) or (  
) on ?  
) light on  
YES  
YES  
NO  
Is the ON/OFF/Reset  
Select Switch in the  
(
) position and  
Central Heating  
Indicator  
the display lit ?  
Domestic Hot  
Water Indicator  
NO  
If no gas, consult your  
supplier.  
Reset  
Burner On  
Indicator  
YES  
Display  
NO  
Boiler operating satisfactorily.  
Check electricity to the  
boiler is switched on.  
Is the Central Heating System  
Pressure needle in the GREEN  
section, between 1 and 2.5 bar ?  
Does the display show an error  
code e.g. E133, E110 ?  
YES  
NO  
NO  
2
1
3
0
4
bar  
YES  
If the reading falls below 1 bar  
repressurise the system as  
described in section 3.1.  
Turn the ON/OFF/Reset  
Selector Switch to Reset.  
If boiler does not  
Reset  
Reset  
Error Code E119 showing low  
pressure.  
4
© Baxi Heating UK Ltd 2012  
2.0 Troubleshooting  
Is the Timer ON and calling for  
heat ?  
Is the Room Thermostat (if  
fitted) set high enough ?  
YES  
YES  
12  
15  
6
Typical  
examples of  
external timer  
CH OFF  
CH ON  
NO  
Turn Room Thermostat to  
maximum setting (typical  
example shown).  
NO  
Ensure timer is set for Central  
Heating ON (see any  
instructions supplied with  
timer).  
15  
CONTACTYOUR  
INSTALLER OR  
SERVICE ENGINEER.  
If you don’t know what you need to do to  
get the boiler to light, or need help with  
the system and controls, contact your  
installer as soon as possible.  
5
© Baxi Heating UK Ltd 2012  
3.0 Repressurising System  
2
3.1  
Central Heating System Pressure  
1
3
1. The water pressure in the central heating system is  
indicated by the pressure gauge.  
4
0
bar  
2. With the system cold and the boiler not operating the  
pressure should be at least 0.5 bar. During operation the  
pressure should not exceed 2.5 bar, and will normally be  
between 1.0 and 2.0 (Fig. 1).  
Fig. 1  
Normal Pressure  
2
3. A pressure of 3 or greater indicates a fault. The safety  
pressure relief valve will operate, at a pressure of 3 (Fig. 3). It  
is important that your Installer or Service Engineer is  
contacted as soon as possible.  
1
3
4
0
bar  
Fig. 2  
4. The minimum pressure for correct operation is 0.5. If the  
pressure falls below 0.5, this may indicate a leak on the  
central heating system (Fig. 2). Error Code E119 will be  
shown on the display.  
Requires  
Repressurising  
2
1
3
3.2  
To Re-Pressurise the System  
4
0
(Optional Filling Loop)  
bar  
1. The procedure is for the optional filling loop kit when  
fitted. However, even if your boiler has an external loop, the  
principle is similar.  
Fig. 3  
Fault  
2. Look at the boiler from underneath. There will be two taps  
at the end of copper pipes, one with a blanking cap on the  
end. Do not operate these taps yet.  
Cap  
Tap  
3. Your installer will have left a metal braided hose (the ‘filling  
loop’) with you for safe keeping.  
Boiler Taps &  
Connections, as  
viewed from  
underneath  
Tap  
4. This loop MUST be connected to the taps. Remove the  
blanking cap and set aside.  
5. Connect the loop to the taps with the wing nuts. These  
should be hand tightened.  
Wing Nut  
6. Carefully open the handles on both taps and check the  
boiler pressure gauge. Once the needle on the gauge is  
above the 0.5 mark both taps can be closed.  
7. Undo the two wing nuts, remove the loop and refit the  
blanking cap. Put the loop in a safe place for future use.  
Loop Connected  
6
© Baxi Heating UK Ltd 2012  
4.0 Clearances  
4.1  
For your Safety  
450mm  
5mm Min  
5mm Min  
1. This appliance must have been installed in accordance  
with the manufacturer’s instructions and the regulations  
in force.  
200mm Min  
(300mm Min if  
using 80/125mm  
flueing system)  
2. Any modification that may interfere with the normal  
operation of the appliance without express written  
permission from the manufacturer or his agent could  
invalidate the appliance warranty. In GB this could also  
infringe the Gas Safety (Installation and Use) Regulations.  
GB - Heating Industry definition meaning England, Scotland,  
Wales, Northern Ireland, Isle of Man and the Channel Isles  
3. Your boiler must not be operated without the casing  
correctly fitted.  
4. Do not interfere with any sealed components on this  
boiler.  
780mm  
5. Take note of any warning labels on your boiler.  
6. Your boiler should have the following minimum  
clearances for Safety and Maintenance  
(Fig. 4):-  
Top  
- 200mm  
Bottom  
Left side  
Right Side  
Front  
- 150mm  
- 5mm  
- 5mm  
- 5mm (In Operation)  
- 450mm (For Servicing)  
150mm Min*  
*This is the MINIMUM recommended dimension.  
Greater clearance than this will aid installation and  
maintenance.  
7. If your boiler is installed in a compartment, do not use  
it for storage purposes. Do not obstruct any purpose  
provided ventilation openings.  
8. Flammable materials must not be stored in close  
proximity to your boiler.  
9. Avoid skin contact when your boiler is in operation, as  
some surfaces may get hot e.g. pipework.  
10. Ensure that the flue terminal, outside the house,  
does not become damaged or obstructed, particularly  
by foliage.  
450mm Min  
For Servicing  
Purposes  
11. It is important that the condensate drain system is  
not blocked, modified or damaged in any way as this  
would affect the operation of your boiler. Your installer  
should have insulated any exposed pipework.  
5mm Min  
Fig. 4  
In Operation  
7
© Baxi Heating UK Ltd 2012  
5.0 Care of the Boiler  
5.1  
Cleaning the Outer case  
The painted panels should be wiped with a damp cloth and  
then dried completely. DO NOT USE ABRASIVE  
CLEANING AGENTS.  
5.2  
Protection & Precaution  
1. The boiler incorporates an integral frost protection feature  
that will operate in both modes. If the boiler temperature falls  
below 5° C, then the boiler will operate until the water  
temperature has been raised.  
2. If a system frost thermostat has been fitted (your installer  
will be able to advise you), then to operate correctly and  
protect your system, the gas and electricity must be left on and  
the appliance set in the central heating mode.  
3. The boiler incorporates an integral pump protection feature  
which continually monitors the time since the pump last  
operated. To prevent seizure, the pump will operate for  
approximately 1 minute if it has not run in the last 24 hours.  
5.3  
Fault Indication  
1. If a fault occurs on the boiler an error code may be shown  
on the facia display (Fig. 5).  
2
Reset  
1
3
0
4
bar  
2. The codes are either two or three digit, preceded by the  
letter 'E'. For example, code E133 will be displayed by 'E1'  
alternating with '33'. E50 is shown as 'E' then '50'.  
Display  
3. E20, E28, E50, E125 & E160 indicate faulty components.  
You should make a note of the displayed error code and  
contact your installer or service engineer.  
Then  
4. If E110 or E130 is displayed overheat of the primary water  
or flue system has occurred. Turn the selector switch to the  
reset position and hold for at least 5 seconds. If the boiler  
does not relight, or the code is displayed regularly contact your  
installer or service engineer.  
Fig. 5  
Table of Error Codes  
5. E119 is displayed when the primary water pressure is less  
than 0.5 bar. After repressurising the system the boiler should  
operate. Your installer will be able to advise you about the  
method of repressurising. See page 6 for further details.  
E20  
Central Heating NTC Fault  
Flue NTC Fault  
E28  
E50  
Hot Water NTC Fault  
E110  
E119  
E125  
E130  
E133  
E160  
Safety Thermostat Operated  
Water Pressure Switch Not Operated  
Circulation Fault (Primary Circuit)  
Flue NTC Operated  
6. E133 indicates that the gas supply has been interrupted,  
ignition has failed or the flame has not been detected. Ensure  
that the gas supply has not been turned off, and turn the  
selector switch to the reset position and hold for at least 5  
seconds. If the boiler does not relight, or the code is displayed  
regularly contact your installer or service engineer.  
Interruption Of Gas Supply or Flame Failure  
Fan or Fan Wiring Fault  
8
© Baxi Heating UK Ltd 2012  
6.0 Legislation  
6.1  
Installation, Commissioning, Service & Repair  
1. This appliance must be install in accordance with the  
manufacturer’s instructions and the regulations in force. Read  
the instructions fully before installing or using the appliance.  
2. In GB, this must be carried out by a competent person as  
stated in the Gas Safety (Installation & Use) Regulations.  
3. Definition of competence: A person who works for a Gas  
Safe registered company and holding current certificates in the  
relevant ACS modules, is deemed competent.  
4. IN IE (Eire), this must be carried out by a competent person  
as stated in I.S. 813 “Domestic Gas Installations”.  
All Gas Safe registered engineers carry an ID card with their  
licence number and a photograph. You can check your  
engineer is registered by telephoning 0800 408 5500 or online  
The boiler meets the requirements of Statutory Instrument  
“The Boiler (Efficiency) Regulations 1993 No 3083” and is  
deemed to meet the requirements of Directive 92/42/EEC on  
the energy efficiency requirements for new hot water boilers  
fired with liquid or gaseous fuels:-  
Type test for purpose of Regulation 5 certified by:  
Notified Body 0085.  
Product/Production certified by:  
Notified Bodies 0086.  
For GB/IE only.  
6.2  
Benchmark Commissioning Checklist  
1. Please ensure that the installer has fully completed the  
Benchmark Checklist on the inside back pages of the  
installation instructions supplied with the product and that you  
have signed it to say that you have received a full and clear  
explanation of its operation. The installer is legally required to  
complete a commissioning checklist as a means of complying  
with the appropriate Building Regulations (England and Wales).  
2. All installations must be notified to Local Area Building  
Control either directly or through a Competent Persons  
Scheme. A Building Regulations Compliance Certificate will  
then be issued to the customer who should, on receipt, write  
the Notification Number on the Benchmark Checklist.  
3. This product should be serviced regularly to optimise its  
safety, efficiency and performance. The service engineer should  
complete the relevant Service Record on the Benchmark  
Checklist after each service.  
4. The Benchmark Checklist may be required in the event of  
any warranty work.  
9
© Baxi Heating UK Ltd 2012  
7.0 Notes  
10  
© Baxi Heating UK Ltd 2012  
8.0 Emergency  
Warning !  
If you smell gas  
Do not operate light switches  
Do not operate any electrical equipment  
Do not use a telephone in the hazardous area  
Extinguish any naked flame and do not smoke  
Open windows and doors in the hazardous area  
Turn off the gas supply at the meter  
Warn any other occupants and vacate the premises  
Telephone the National Gas Emergency Service on:-  
0800 111 999  
Faulty boiler  
If it is known or suspected that a fault exists  
on the boiler, it must not be used until the fault  
has been corrected by a competent person.  
In an Emergency  
If a water or gas leak occurs or is suspected, the boiler can  
be isolated at the inlet valves as follows;  
1. Using a suitable open ended spanner, turn the square  
nut on the gas tap through 90° (1/4 turn) to isolate the gas  
supply at the boiler (Fig. 6).  
Gas Tap  
3. The water isolating valves are positioned under the  
boiler and can be closed by turning their taps to the right  
towards the wall (Fig. 6).  
4. Call your Installer or Service Engineer as soon as  
possible.  
Fig. 6  
Heating Flow, Heating  
Return and Mains Water  
Inlet Isolating Valves  
11  
© Baxi Heating UK Ltd 2012  
Please complete the boxes below  
9.0 Warranty & Service  
Serial Number  
Standard Warranty Term & Conditions  
12 Months Free Warranty - register today  
To receive your 12 months free warranty please complete the form supplied  
with the boiler or simply call heateam, the service of Baxi Heating UK Ltd on  
0800 731 1644.  
Our promise to you  
If you experience a fault with your new boiler, we aim to provide a safe and  
high quality repair service supported by our dedicated national network of  
highly skilled engineers. If your installer can’t resolve the problem for you, we  
will do everything we can to get an engineer out to you as quickly as possible.  
Nothing in this warranty will affect your statutory consumer rights.  
Date of Installation  
D
D
M M  
Y
Y
What you need to do if you experience a problem with your heating system  
or the operation of the boiler  
Installer Details (name, address and contact number(s))  
You should always contact your installer first, because the fault may not be  
related to the boiler. If your installer confirms that the fault is within the boiler  
it self and he/she can’t repair it, our friendly customer service team is on hand  
to help. Simply call our service division heateam on 0844 871 1560 to book an  
engineer visit or for any general advice that you may need. Our contact centre  
is open Monday to Friday 8am - 6pm, weekends and Bank Holidays 8.30am -  
2pm, excluding Christmas Day and New Years Day.  
When calling heateam it would be helpful if you could have the following  
information to hand:-  
1
2
3
4
boiler serial number (see opposite).  
boiler make and model number.  
Your installer name and address details.  
Proof of purchase (if you do not have the boiler serial number).  
What this warranty covers  
Free of charge repair or replacement of components found to be faulty from  
manufacture.  
Free of charge replacement of the complete unit provided always that the  
failure is related to a manufacturing fault that cannot be repaired or is  
uneconomic to repair.  
The warranty runs for 12 months from the date your product is installed.  
What this warranty does not cover  
Repairs to boilers which haven’t been installed and commissioned properly,  
and as set out in the installation instructions (this includes the need to flush the  
system effectively and add a suitable corrosion inhibitor).  
Any damage caused by hard water scale deposits and/or aggressive water  
resulting from corrosion.  
Any other defects or failures, either in the connected heating system or  
outside of the boiler itself.  
Faults caused by inadequate supply of electricity, gas or water to the property.  
Installations within commercial settings for which this boiler was not designed.  
Information Label  
Reimbursement of any third party repair or replacement costs that we haven’t  
been told about or agreed with you in advance.  
All descriptions and illustrations provided in this leaflet have been carefully  
prepared but we reserve the right to make changes and improvements in  
our products which may affect the accuracy of the information contained in  
this leaflet. All goods are sold subject to our standard Conditions of Sale  
which are available on request.  
Compensation for consequential losses (e.g. loss of earnings, business losses,  
stress and inconvenience) arising from a production breakdown, including  
repair delays caused by factors outside our reasonable control.  
Annual Service  
To ensure you receive the maximum efficiency from your boiler we  
recommend your boiler has an annual service so you and your family can  
continue to enjoy heating and hot water comfort. To arrange an annual service  
from one of our Baxi Heating UK Ltd heating experts, please call  
Tel: 0844 871 1545  
POTTERTON  
A Trading Division of Baxi Heating UK Ltd (3879156)  
Brooks House, Coventry Road, Warwick. CV34 4LL  
After Sales Service 0844 871 1560 Technical Enquiries 0844 871 1555  
e&oe  
UK Comp No 5114443 - Iss 16 - 4/12  
© Baxi Heating UK Ltd 2012  

AIPTEK Action Z5X5P User Manual
Alpine 68 21627Z13 A User Manual
Alpine INA W910 User Manual
Black Decker IB53 User Manual
Black Decker MM327 User Manual
Canon LC 600 User Manual
Clarion RDX455D User Manual
Creative Inspire T6200 User Manual
Hitachi Camcorder H610E User Manual
IDEAL INDUSTRIES CLASSIC HE9 User Manual