MODEL:
EARC15RE1
EARC18RE2
EARC22RE2
EARC24RE2
INTRODUCTION
IMPORTANT SAFETY INSTRUCTION ...........................................................................1
ELECTRICAL REQUIREMENTS ...................................................................................2
PACKING LIST ............................................................................................................3
INSTALLATION & ASSEMBLY INSTRUCTIONS ............................................................. 4
USING YOUR AIR CONDITIONER ................................................................................13
OPERATING YOUR AIR CONDITIONER ........................................................................15
CARE AND CLEANING ................................................................................................ 16
TROUBLESHOOTING .................................................................................................17
below:
1
15K
18K/22K/24K
2
5/16" Long Hex-head Screw
5/8" Long Hex-head Screw
1/2" Long Hex-head Screw
5/8" Long Flat Head Bolt and
Locknut
Sill Angle Bracket
1/2" Long Flat Head Bolt and
Locknut
Gasket
Support Bracket (with R and L )
3
15K/18K
17.91
22K/24K
18.625
23.625
26.50
19.00
19.50
28.00
41.00
30.00
41.00
4
(15K/18K See FIG.1/FIG.2 ; 22K/24K See FIG.3/FIG.4).
FIG.1
FIG.2
SASH
SASH
19 MIN
1/2 MIN
1/2 MIN
19 MIN
1/2 MIN
Storm WindowFrame
or Obstruction
Storm WindowFrame or Obstruction
FIG.3
FIG.4
SASH
SASH
19 1/2 MIN
1/2 MIN
1/2 MIN
19 1/2 MIN
1/2 MIN
Storm WindowFrame
or Obstruction
Storm WindowFrame or Obstruction
5
FIG.5
FIG.6
FIG.5
FIG.6
FIG.7 & 8
FIG.9
FIG.9
FIG.7
FIG.8
6
6. Remove the six screws from the cabinet. (Top, left, and right has two screws.) (FIG.10)
FIG.10
FIG.11
FIG.11
8.Take the pearl cotton for 24K. (FIG.12)
FIG.12
7
FIG.13a
FIG.13a
Head
5/16
Long
Hex-head
Screw
FIG.13b-14.
FIG.13b
5/16" Long
Hex-head Screw
FIG.14
(Suggest to keep a downward angle, to let
accumulated rain water to drain out, from back side
of the unit bottom.)
8
Long Flat head
Bolt and Locknut
5/8" Long Flat Head Bolt
5
(It should set on the gasket for 22K/24K)
Long
Flat head Bolt
and Locknut
5/8" Long
Hex-head Screw
Gasket
5/8" Long
Hex-head Screw
1/2" Long
Hex-head Screw
9
FIG.15
10
15K/18K
22K/24K
18 1/4 (46.4 cm) 19 1/2 (49.5 cm)
23 7/8 (60.6 cm) 26 9/10 (68.3 cm)
FIG.16
Y
(Page 6 and 7)
FIG.17
FIG.18
11
FIG.19
FIG.20
12
Cool Mode: The cooling function allows the air
conditioner to cool the room and at the same time
reduces humidity. Press the MODE button to
activate the cooling function. To optimize this
function adjust the temperature by pressing the up
and down arrows and the speed by pressing the
Fan Speed button.
Dry Mode: This function reduces the humidity of
the air to make the room more comfortable. Press
MODE button to set the DRY mode. An automatic
function of alternating cooling cycles and air fan
is activated.
AUTO
SPEED
AUTO
MODE
Fan Mode: This mode will only circulate the air.
Press MODE button to select FAN MODE.
Pressing the FAN SPEED button allows you to
change the fan speed setting from HI, MED, and
LO. If using the remote control, it will store the fan
speed setting of the previous use.
Auto Mode: In AUTO mode the unit automatically
chooses the fan speed and the mode of operation
(COOL, DRY, or FAN). In this mode the fan speed
and the temperature are set automatically
according to the room temperature (Room
temperature is determined by the temperature
sensor located in the indoor unit.).
5. Timer Button:Use buttons on the control panel
and remote to set the TIMER.
Timer Off: The timed stop is programmed by
pressing the TIMER button. Set the stop time by
pressing the button
or
until your
desired stop time is displayed, then press TIMER
button again.
1. Digital Display: Shows the set temperature.
Operation modes are: Cool, Dry, Fan, and Auto.
Time is displayed using the timer setting.
Timer On: When the unit is off, press TIMER
button first, set the temperature with pressing
the button
a second time, set the stop time with pressing the
button or . Press TIMER button a
or
. Press TIMER button
third time, confirm your settings and stop time.
The display will show the time your machine will
automatically turn on.
2.
and
Button: Use these buttons on the
control panel and remote to increase or decrease
the Set Temperature or Timer.
Note: It can be set to automatically turn off or on in
0.5-24 hours. Each press of the
Temperature range: 61 ~88 or 16 ~31 .
buttons will increase or decrease the timer. The
Timer can be set in 0.5 hours increment below 10
hours and 1 hour increment for 10 hours or above.
The SET light will turn on while setting.
To cancel the set function, press the TIMER button
again.
3. Power Button: Turn the air conditioner on and
off.
4. Mode Button: Press the mode button to cycle
through the various modes: Cool, Dry, Fan and
Auto.
13
6. Eco Button: When the unit is in ECO mode, the
light will turn on. In ECO mode, the unit will
turn-off once the room is cooled to the user set
temperature. The fan will also be off at this point.
The unit will turn back on when the room
10.Directional Louvers: Use the horizontal wheels
to control horizontal airflow and the air deflectors
to control vertical airflow.
temperature rises above the user set temperature.
Before the compressor stars, the fan motor will
run for a while, then it will stop for a while-and will
repeat to provide a much more comfortable-feeling
and save energy.
air deflector
horizontal wheel
air deflector
7. Sleep Button: Press the SLEEP button, the Sleep
Light will be on after 10s. and the remaining lights
on the display will be off. In SLEEP mode, the air-
conditioner will automatically adjust the
temperature and fan speed to make the room more
comfortable during the night. The set temperature
will automatically raise by 1
minutes and at most change six times until the set
temperature is 28
every 30-60
.
Run time will depend on set temperature.
8. Fan Speed Button: Press the FAN SPEED button
to select the fan speed. In COOL MODE you can
choose the following settings: HI, MED, LO, or
AUTO. In FAN MODE you can choose from HI,
MED, and LO.
9. Fiter Button: The Filter Check light will only turn
on as a reminder to clean the filter after the fan
motor has been in operation for a total of 500
hours. To turn the light off, press the Filter Check
button.
14
5. Timer: Use buttons on the control panel
and remote to set the TIMER.
Timer Off: The timed stop is programmed by
pressing TIMER button. Set the stop time by
pressing the button
or
until your
desired stop time is displayed, then press TIMER
button again.
1
2
7
Timer On: When the unit is off, press TIMER
button first, set the temperature with pressing
the button
a second time, set the stop time with pressing the
button or . Press TIMER button a
or
. Press TIMER button
3
4
third time, confirm your settings and stop time.
The display will show the time your machine will
automatically turn on.
Note: It can be set to automatically turn off or on in
0.5-24 hours. Each press of the
buttons will increase or decrease the timer. The
Timer can be set in 0.5 hours increment below 10
hours and 1 hour increment for 10 hours or above.
The SET light will turn on while setting.
To cancel the set function, press the TIMER button
again.
8
9
5
6
10
3
6. Auto Mode: In AUTO mode the unit automatically
chooses the fan speed and the mode of operation
(COOL, DRY, or FAN). In this mode the fan speed
and the temperature are set automatically
according to the room temperature (Room
temperature is determined by the temperature
sensor located in the indoor unit.).
1. Power: Turn the air conditioner on and off.
7. Fan Speed: Press the FAN SPEED button
to select the fan speed. In COOL MODE you can
choose the following settings: HI, MED, LO, or
AUTO. In FAN MODE you can choose from HI,
MED, and LO.
2. Cool: Press the COOL button to COOL mode.
3.
and
: Use these buttons on the control
panel and remote to increase or decrease the
Set Temperature or Timer. Temperature range:
61 ~88 or 16 ~31 .
8. Display: To press the DISPLAY button, it can
switch off/on all lights or LED display.
9. Eco: When the unit is in ECO mode, the
light will turn on. In ECO mode, the unit will
turn-off once the room is cooled to the user set
temperature. The fan will also be off at this point.
The unit will turn back on when the room
temperature rises above the user set temperature.
Before the compressor stars, the fan motor will
run for a while, then it will stop for a while-and will
repeat to provide a much more comfortable-feeling
and save energy.
4. Sleep: Press the SLEEP button, the Sleep
Light will be on after 10s. and the remaining
lights on the display will be off. In SLEEP mode,
the air-conditioner will automatically adjust the
temperature and fan speed to make the room
more comfortable during the night. The set
temperature will automatically raise by 1
every 30-60minutes and at most change six
times until the set temperature is 28
And every Run time will depend on set
temperature.
.
10. Fan Only: Press the Fan Only button to FAN
ONLY mode.
15
FIG.21
FIG.21
16
17
For any questions or Technical Support,
Please Call Customer Service: 1-844-801-8880