Delonghi Dehumidifier Den500p Instruction User Manual

D E 3 0 0 / 3 0 0 P / 4 0 0 / 4 0 0 P / D H 4 0 0 P / D E 5 0 0 / 5 0 0 P / D E 6 5 0 P  
DEHUMIDIFIER  
DEHUMIDIFIERUSE AND MAINTENANCE MANUAL  
SAVE THESE INSTRUCTIONS  
DÉSHUMIDIFICATEUR  
MODE D’EMPLOI  
CONSERVEZ CE MODE D’EMPLOI  
DESHUMIDIFICADOR  
INSTRUCIONES PARA EL USO  
REPASE Y GUARDE ESTAS INSTRUCCIONES  
LEA CUIDADOSAMENTE ESTE INSTRUCTIVO ANTES DE USAR SU APARATO  
DEUMIDIFICATORE  
ISTRUZIONI D’USO  
CONSERVARE LE PRESENTI ISTRUZIONI  
Register this product on-line and receive a free trial issue of “Cook's Illustrated”. Visit www.delonghi-registra-  
tion.com. Visit www.delonghi.com for a list of service centers near you. (U.S. and Canada).  
Veuillez enregistrer ce produit on-line et Vous recevrez une copie gratuite du magazine Cook's  
Illustrated”.Visitez www.delonghi-registration.com.  
Visitez www.delonghi.com pour trouver le centre d'assistance le plus proche de chez vous (U.S. et Canada).  
Registre su producto en nuestra web y reciba una muestra de prueba de “Cook's Illustrated”.  
visite www.delonghi-registration.com. Visite www.delonghi.com para consultar la lista de nuestros centros  
de asistencia más cercanos (ee. uu. y Canada).  
Registrate questo prodotto on-line e riceverete una copia gratuita della rivista Cook's Illustrated”.  
Visitate www.delonghi-registration.com. Visitate il sito www.delonghi.com per trovare il centro assistenza  
autorizzato a Voi più vicino (U.S. e Canada).  
ELECTRONIC CHARACTERISTICS/CARACTÉRISTIQUES ÉLECTRONIQUES  
CARACTERISTICAS ELECTRICAS/CARATTERISTICHE TECNICHE  
115V-60Hz  
Description  
Description of the appliance  
4
1
2
5
6
3
7
8
1. Control panel  
5. Water Tank  
2. Cabinet  
6. Power Cord  
3
Wheels  
7. Continuous Draining Outlet  
8. Pump connection (only on some  
models)  
4. Air Filter  
Description of the control panel  
Room  
temperature  
button  
MODE  
button  
Display  
°F/°C  
ON light  
Defrost light  
Fan speed  
button  
TURBO POWER  
button  
Pump light *  
Tank warning light  
TIMER  
button  
PUMP button *  
Decrease  
humidity level/  
time button  
Increase  
humidity level/  
time button  
STAND-BY  
button  
* (only on some models)  
4
Control panel  
STAND-BY button  
Press this button to start /stop the appliance. To turn the appliance completely off, remo-  
ve the plug from the outlet.  
Room temperature button  
Press this button to display the Temperature on the LCD display. If you press the button once  
the display will show the °F . If you press the button twice, the display will show the tempe-  
rature in °C. After few seconds, the display will automatically show the humidity level.  
FAN speed button  
Press this button to select the Fan Speed (High, Medium, Low).  
Decrease or increase Humidity Level/ Time buttons  
These buttons are used to adjust the desired humidity level, with 5% increments; they are  
also used to set the timer.  
From 0 -10 the hours increase by 30 min. and from 10-24 the hours increase by 1 hour increments.  
TIMER button  
With the appliance switched ON, if you press the TIMER button the display will show the  
hours after which you want the appliance to switch OFF (1-2-3... hours ).  
With the appliance in the STAND-BY position, if you press the TIMER button the display will  
show the hours after which you want the appliance to switch ON (1-2-3... hours ).  
MODE button  
Press this button to select the Fan only or Dehumidifier modes.  
TURBO POWER button  
Use this button to activate the “turbo power” function. In this mode, the appliance will  
operate at maximum fan speed and in continuous mode. If pressed again, the unit will  
revert back to previous settings.  
PUMP button (only on pump models)  
Use this button to activate the heavy-duty pump system for active drainage.  
5
Display lights  
ON light  
When the STAND-BY button is pressed to start the unit, the ON light will come on automati-  
cally. The light will go off again when the unit is switched off.  
NOTE: After a power outage, the unit will not switch itself on again automatically. When the  
power supply has been reestablished, please press the STAND-BY button to start the unit  
again.  
TANK Warning light  
If the water tank is full, improperly positioned or missing, the tank warning light will start  
blinking.  
An alarm will sound until the tank is either emptied or correctly positioned into place.  
DEFROSTING light  
With an ambient temperature of less than 15°C, (59°F) the appliance performs defrosting  
cycles.  
While the appliance is defrosting, the defrosting light comes on and remains on until defro-  
sting is completed.  
During the defrosting cycle only the following 4 keys are active:  
pump button, stand-by button, temperature button, timer button.  
PUMP light (only on some models)  
Once the pump button is pressed the pump light will switch on.  
If the pump light flashes it means that the pump is not functioning properly.  
6
Installation Instructions  
1. Allow at least 12 inches (30cm) of space on all sides of the unit for good air circulation.  
2. Install your dehumidifier on a floor, table, or shelf. When installing the unit on a table or shelf,  
make sure the table or shelf is strong enough to support the weight of the unit with a full  
bucket.  
Note: The dehumidifier needs to be secured when installed on a table or a shelf.  
Do not sit or stand on the dehumidifier.  
3. The tank must be properly positioned.  
4. Castor wheels let you move the dehumidifier easily.  
Choosing the proper location for the unit  
1. Use the unit in a basement to help prevent moisture damage.  
2. Use the unit in cooking, laundry, bathing, and dishwashing areas that have excessive moi-  
sture.  
3. Use the unit to prevent moisture damage anywhere books or valuables are stored.  
4. Place the unit where you want to have comfortable conditions.  
List of components  
For models equipped with pump system:  
• 16 ft. (5 m) clear hose with Quick-Connect connection  
• 3 ft. (1 m) clear hose  
For all other models:  
• 3 ft. (1 m) clear hose  
Required tools and assembly time  
Collection tank:  
No assembly or plumbing necessary.  
Continuous draining outlet:  
To use the Continuous Draining feature the following tools will be necessary:  
• 5 mm (0.2 in.) drill bit (to drill open the draining outlet)  
• Drill tool  
The estimated assembly time is 1-2 minutes.  
Pump system and Quick-Connect 16ft. hose (only on models equipped with pump system):  
No tools necessary. The estimated assembly time is 1-2 minutes.  
7
Disposing of the collected  
water  
A) Empty the tank manually.  
When the tank is full, remove (fig.1) and  
empty it into a sink.  
When finished, replace it properly.  
NOTE: The tank must be positioned properly.  
If you hear the intermittent sound of the  
beep, it means the tank is not in the proper  
position.  
fig. 1  
B) Continuous draining.  
Condensed water can be drained via a hose  
connected to the outlet located in the lower  
part of the tank proceeding in the following  
way:  
1. remove the water tank.  
Drill  
fig. 2  
2. Using a 5 mm drill bit, (0.2 inches) drill a hole  
in the base of the tank along the torus as  
shown in figure 2.  
3. Connect a hose to the hose connector (fig.  
3). Be sure the hose does not kink or bend.  
Make sure that the hose is not higher than the  
hose connection (see figure 4).  
NOTE: When you remove the rubber cap  
keep it in a safe place in case you want  
drain into the tank.  
fig. 3  
fig. 4  
C) Continuous draining using the pump  
(only on pump models)  
The exclusive heavy-duty pump system allows  
water removal of up to 13.12 feet (4m) in height.  
If you want the water to flow directly to a drain,  
connect the condensation discharge tube sup-  
plied to the connection pipe located on the  
lower part of the unit (Fig. 5).  
Hose  
Drain  
Select the dehumidifying function and press the  
PUMP button.  
Note: With the condensation discharge hose  
missing and the pump switched ON, the pump  
light will start blinking. To eliminate this problem:  
•Check the hose is correctly positioned;  
•Disconnect and reconnect the appliance.  
fig. 5  
8
Selecting the operations  
Stand-by position  
Once the power outlet is plugged in, the display will show on the left side the degree of humi-  
dity you want to reach (the default data is 60) and on the right side the display will show (for  
a minute) two dots, followed by the room humidity level.  
How to Select the Desired Humidity Level  
1) Push the stand-by button.  
2) Press the  
button to set the desired humidty level. (30% means a dry environment,  
80% a humid environment).  
3) Push the MODE button to choose the dehumidifying function; the function is selected when  
the small dot on the display is under the symbol).  
4) When the appliance reaches the humidity set point the appliance will automatically stop  
working. As soon as the humidity increases above the set point, the appliance will auto-  
matically resume dehumidification operation.  
Note: The appliance is equipped with a safety device. The appliance only works after 3 minu-  
tes from the last time it was turned off.  
How to use the FAN function  
1) Push the stand-by button.  
2) Push the MODE button to choose the FAN function; the function is selected when the small  
dot on the display is under the  
symbol).  
3) Press the  
button to modify the ventilation speed (min/med/max).  
Turbo power  
1) Press the  
button.  
2) The turbo power function is an automatic dehumidification function that is used when you  
wish to operate the appliance at maximum power. When in this mode, the display will show  
on the left side (two dots) and on the right side the room humidity present.  
To stop the turbo power function, simply press the  
button again.  
How to program the delayed start function: From the OFF Position  
1) With the unit OFF, press the  
button and use the  
button to set the number of  
hours after which the appliance should start functioning.  
2) On the left side the display will show the number of hours after which the appliance should  
start the operation (1-24h) and a small dot under the  
function has been selected.  
symbol indicates that the timer  
3) When the selected time is reached, the appliance will start working.  
9
Selecting the operations  
How to Program the delayed stop function: From the ON Position  
1) Press the  
button and use the  
button to set the number of hours after which the  
appliance should stop functioning.  
2) The left side the display will show the number of hours after which the appliance should stop  
the operation (1-24h) and a small dot under the  
tion has been selected.  
symbol indicates that the timer func-  
3) When the selected time is reached, the appliance will stop working.  
10  
Care and Maintenance  
WARNING  
Electrical Shock Hazard  
Always disconnect power supply cord from outlet before performing any maintenance.  
Failure to follow the below precautions could result in the electrical shock or personal  
injuries.  
Maintenance  
Your dehumidifier is designed to serve you year-round.  
Listed below are the care and maintenance instructions  
Cleaning the Front Panel and Cabinet  
Using a soft cloth, clean the front panel and cabinet with warm water and a mild soap or  
detergent. NOTE: Never sprinkle water into the appliance in order to prevent risk of short-  
circuit and fire.  
Never use gasoline, thinner or any other similar chemicals for cleaning.  
Do not use bleach or abrasives.  
Cleaning the Air Filter  
If the filter is dirty, air circulation is compromised and the efficiency of the dehumidifying  
decreases. It is therefore good practice to clean the filter at regular intervals. The frequency  
depends on the duration and conditions of operation.  
• To remove the air filter, pull it out (Fig. 6).  
• Use a vacuum cleaner to remove dust accumulations from  
the filter. If the filter is very dirty, wash in warm water and  
rinse several times.  
• After washing the filter, allow it to dry completely before  
replacing it.  
fig. 6  
11  
Troubleshooting tips  
Often times, a problem is minor and a service call may not be necessary. Use this trouble-  
shooting guide to identify possible problems you may be experiencing.  
Problem  
Possible cause  
Remedy  
•Plug into the power outlet  
•Check power cord con-  
nection.  
•Check if water tank is full  
•Check water tank is pro-  
perly installed.  
Unit does not operate  
•Empty the tank  
•Position the tank correctly  
•Turn the unit on  
•Check if the unit is not tur-  
ned on.  
•The desired humidity may  
be lower than the room  
humidity.  
•Clean the filter  
•Air filter is dirty and /or  
blocked.  
•Ambient room temperature  
too low.  
Dehumidifying capacity (moi-  
sture removal) low  
•Increase the room tempe-  
rature  
•Poor airflow  
•Improve the airflow  
circulation/obstruction  
•The desired humidity is lower  
then the room humidity  
•There are windows or  
doors opened  
•Area/room is too large for  
the capacity of the dehu-  
midifier  
•Check that the doors and  
the windows are closed.  
Relative Humidity setting not  
reached after long period of  
operation  
The appliance does not work  
in the 3 minutes since the last  
swith off  
•The safety device has  
been activated  
•Wait 3 minutes to pass  
•Contact the Service  
Center  
The display shows  
E1”/“E2”/“E3”  
The pump lamp blink  
•The condensation dischar-  
ge hose is not positioned  
corretly or is bent.  
•Check the hose is correctly  
positioned  
•Disconnect and reconnect  
the appliance  
12  
Limited Warranty  
This warranty applies to all home appliances with De’Longhi or Kenwood brand names.  
FOR CONTIGUOUS UNITED STATES ONLY  
Limited Warranty  
We warrant each De’Longhi appliance to be free from defects in material and workmanship.  
From the purchase date, our obligation under this warranty is to provide one (1) year free parts  
and labor on the entire appliance, with an additional four (4) years free on any part of the sea-  
led system consisting of the compressor, evaporator, condenser and factory connected refri-  
gerant tubing. Labor and all other parts during the additional four (4) year warranty are to be  
paid by the owner. All appliances in need of repair are to be shipped to an authorized  
De’Longhi service center at the owner’s expense, and De’Longhi will then incur the return ship-  
ping costs. After the first five (5) years of ownership, all expenses (all parts, labor and shipping)  
are to be paid by the owner of the unit. This warranty shall apply only if the appliance is used  
in accordance with the factory directions that accompany it, and on an Alternating Current  
(AC) circuit. This warranty is in lieu of all other warranties and representations, expressed or  
implied, and all other obligations or liabilities on our part. We do not authorize any other per-  
son or company to assume for us any liability in connection with the sale or use of our applian-  
ce. This warranty shall not apply to any appliance that has been repaired or altered outside  
our factory nor shall it apply to any appliance that has been subjected to misuse, negligence  
or accidents.  
If repairs become necessary, see contact information below:  
U.S. Residents:  
Please contact our toll free hotline at 1-800-322-3848 or log onto our website at  
For all accessories, spare parts or replacement parts, please contact our parts division at 1-  
800-865-6330.  
Residents of Canada:  
Please contact our toll free hotline at 1-888-335-6644 or log onto our website at  
Other countries:  
13  

Soleus Air Soleusair Sg Ttw 12esez 26 User Manual
Savin C7570 User Manual
Samsung Aqt24w6wb User Manual
Ricoh Pro 1357ex User Manual
NEC NP PA572W 02 User Manual
Little Wonder 8160 User Manual
LG LG D213N User Manual
LEVOIT VESYNC DUAL 200S User Manual
KENWOOD HM670 User Manual
JVC BR DV600E User Manual