DELIBERANT APC 5M 18 V2 User Manual

APC 5M-18 V2  
Quick Installation Guide  
Revision 1.0  
15 July 2011  
ꢀŽƉLJƌŝŐŚƚꢁΞꢁ2011 Deliberant www.deliberant.com  
Quick Installation Guide  
Contents  
ꢀꢁŽŶƚĞŶƚƐꢀ  
Copyright .............................................................................................................................................2  
Notice ..................................................................................................................................................2  
Trademarks .........................................................................................................................................2  
CONTENTS ...........................................................................................................................................3  
INTRODUCTION....................................................................................................................................4  
FCC Warning.......................................................................................................................................4  
FCC Caution ....................................................................................................................................4  
FCC Radiation Exposure Statement ...............................................................................................4  
Antenna Installation .........................................................................................................................4  
Antenna Compliance .......................................................................................................................4  
CE Mark Warning................................................................................................................................5  
R&TTE Compliance Statement...........................................................................................................5  
Safety...............................................................................................................................................5  
EU Countries Intended for Use........................................................................................................5  
EU Countries Not Intended for Use .................................................................................................5  
ABOUT THIS GUIDE.............................................................................................................................6  
Prerequisite Skills and Knowledge......................................................................................................6  
Definitions, Acronyms and Abbreviations............................................................................................6  
Technical Support ...............................................................................................................................6  
Contact Us...........................................................................................................................................6  
INSTALLATION.....................................................................................................................................7  
Package Contents...............................................................................................................................7  
Hardware Introduction.........................................................................................................................8  
LEDs ................................................................................................................................................8  
Assembling and mounting the APC 5M-18 V2....................................................................................9  
ACCESS THE APC 5M-18 V2.............................................................................................................11  
Connection via WEB Browser ...........................................................................................................11  
Resettingto Factory Defaults............................................................................................................12  
deliberant  
Page 3  
Quick Installation Guide  
Introduction  
ꢀ/ŶƚƌŽĚƵĐƚŝŽŶ  
FCC Warning  
This equipment has been tested and found to comply with the limits for a Class B digital device,  
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection  
against harmful interference in a residential installation.  
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and  
used in accordance with the instructions, may cause harmful interference to radio communications.  
However, there is no guarantee that interference will not occur in a particular installation. If this  
equipment does cause harmful interference to radio or television reception, which can be determined  
by turning the equipment off and on, the user is encouraged to try to correct the interference by one of  
the following measures:  
ƒ
ƒ
ƒ
Reorient or relocate the receiving antenna.  
Increase the separation between the equipment and receiver.  
Connect the equipment into an outlet on a circuit different from that to which the receiver is  
connected.  
ƒ
ƒ
Consult the dealer or an experienced radio/TV technician for help.  
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two  
conditions: (1) This device may not cause harmful interference, and (2) this device must accept  
any interference received, including interference that may cause undesired operation.  
FCC Caution  
To assure continued compliance, any changes or modifications not expressly approved by the party  
responsible for compliance could void the user's authority to operate this equipment.  
FCC Radiation Exposure Statement  
To comply with FCC RF exposure requirements in section 1.1307, a minimum separation distance of  
3.9 feet is required between the antenna and all occupational persons, and a minimum separation  
distance of 8.7 feet is required between the antenna and all public persons.  
Antenna Installation  
:$51,1*ꢂꢀ,WꢀLVꢀLQVWDOOHU¶VꢀUHVSRQVLELOLW\ꢀWRꢀHQVXUHꢀWKDWꢀZKHQꢀXVLQJꢀWKHꢀDXWKRUL]HGꢀDQWHQQDVꢀLQꢀWKHꢀ  
United States (or where FCC rules apply), only those antennas certified with the product are used.  
The use of any antenna other than those certified with the product is expressly forbidden in  
accordance to FCC rules CFR47 part 15.204. The installer should configure the output power level of  
antennas, according to country regulations and per antenna type. Professional installation is required  
of equipment with connectors to ensure compliance with health and safety issues.  
Antenna Compliance  
The APC 5M-18 V2 radio module contains internal antenna.  
deliberant  
Page 4  
Quick Installation Guide  
Introduction  
CE Mark Warning  
This is a Class A product. In a domestic environment this product may cause radio interference in  
which case the user may be required to take adequate measures.  
R&TTE Compliance Statement  
This equipment complies with all the requirements of the Directive 1999/5/EC of the European  
Parliament and the Council of 9 March 1999 on Radio Equipment and Telecommunication Terminal  
Equipment and the Mutual Recognition of their Conformity (R&TTE).  
The R&TTE Directive repeals and replaces in the directive 98/13/EEC (Telecommunications Terminal  
Equipment and Satellite Earth Station Equipment) As of April 8, 2000.  
Safety  
This equipment is designed with the utmost care for the safety of those who install and use it.  
However, special attention must be paid to the dangers of electric shock and static electricity when  
working with electrical equipment. All guidelines of this manual and of the computer manufacturer  
must therefore be allowed at all times to ensure the safe use of the equipment.  
EU Countries Intended for Use  
The ETSI version of this device is intended for home and office use in Austria, Belgium, Denmark,  
Finland, France (with Frequency channel restrictions), Germany, Greece, Ireland, Italy, Luxembourg,  
The Netherlands, Portugal, Spain, Sweden and United Kingdom.  
The ETSI version of this device is also authorized for use in EFTA member states Iceland,  
Liechtenstein, Norway and Switzerland.  
EU Countries Not Intended for Use  
None.  
deliberant  
Page 5  
Quick Installation Guide  
About this Guide  
ꢀꢂďŽƵƚꢀƚŚŝƐꢀ'ƵŝĚĞ  
Prerequisite Skills and Knowledge  
To use this document effectively, you should have a working knowledge of Local Area Networking  
(LAN) concepts and wireless Internet access infrastructures.  
Definitions, Acronyms and Abbreviations  
The following typographic conventions and symbols are used throughout this document:  
Additional information that may be helpful but which is not required.  
Important information that should be observed.  
bold  
italic  
code  
Menu commands, buttons, input fields, links, and configuration keys are displayed in bold  
References to sections inside the document are displayed in italic.  
File names, directory names, form names, system-generated output, and user typed  
entries are displayed in constant-width type  
Technical Support  
If you encounter problems when installing or using this product, please consult the Deliberant website  
ƒ
ƒ
ƒ
Direct contact to the Deliberant support centers.  
Frequently Asked Questions (FAQ).  
Download area for the latest software, user documentation and product updates.  
Contact Us  
EU office:  
US office:  
UAB WILIBOX Veiveriu 150 - IIIa. Kaunas, Deliberant  
LT-46391  
138 Mountain Brook Drive  
Lithuania  
Canton, GA 30115  
United States of America  
For support: [email protected]  
For sales enquiries: [email protected]  
deliberant  
Page 6  
Quick Installation Guide  
Installation  
ꢀ/ŶƐƚĂůůĂƚŝŽŶꢀ  
This chapter provides installation instructions for the hardware components of the APC 5M-18 V2.  
Package Contents  
The figure below displays APC 5M-18 V2 package contents.  
Figure 1 ± APC 5M-18 V2 Package Contents  
Item  
A
Component Name  
Quantity  
APC 5M-18 V2 Quick Installation Guide  
APC 5M-18 V2 enclosure  
1
1
1
1
1
1
1
1
1
3
1
B
C
Power adapter  
D
PoE injector  
E
Gland cap for the CAT5 Ethernet cable  
Rubber gasket for the CAT5 Ethernet cable  
Mounting bracket for wall/pole mount  
U bolt M6 for pole mounting  
Hexagon bolt M6 x 18 for wall/pole mount  
Hexagon lock nut M6  
F
G
H
I
J
K
Anti-slip washer M6  
If any of these items are missing or damaged, please contact your reseller.  
deliberant  
Page 7  
Quick Installation Guide  
Installation  
Hardware Introduction  
APC 5M-18 V2 is housed in a plastic enclosure ensuring a reliable sealing in a wide range of  
temperature and has an integrated 18dBi panel antenna.  
Figure 2 ± APC 5M-18 V2 Overview  
The panel of the APC 5M-18 V2 contains:  
ƒ
ƒ
ƒ
Ethernet/Power connection in the form of passive PoE through standard Ethernet cable  
6 LEDs: power LED, LAN activity LED and 4 LEDs for device RSSI level indication  
Grounding stud  
The APC 5M-18 V2 has label with the following information:  
Figure 3 ± APC 5M-18 V2 Label  
The label of the APC 5M-18 V2 contains:  
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
Model name. The official model name is APC 5M-18 V2.  
Serial Number  
Radio MAC address  
LAN MAC address  
FCC ID: UB8-APC5M18V2  
IC ID: 6607-APC5M18V2  
LEDs  
The APC 5M-18 V2 has 6 LEDs located on the side panel: power, LAN and 4 RSSI LEDs. The  
various states of the LEDs indicate different connection operations as follows:  
LED  
Color  
Status  
Indication  
Power  
Green  
On  
APC 5M-18 V2 is active/working  
No power on APC 5M-18 V2  
LAN connection exists.  
Off  
LAN  
Green  
On  
Blinking  
Off  
Indicates the traffic on LAN interface.  
No LAN connection.  
RSSI (1, 2, 3, 4) Yellow  
On  
The RSSI level has reached the appropriate threshold  
level (default RSSI threshold levels: 10, 25, 35, 50)  
Off  
The RSSI level has not reached the appropriate  
threshold level  
deliberant  
Page 8  
Quick Installation Guide  
Installation  
Assembling and mounting the APC 5M-18 V2  
The APC 5M-18 V2 XQLW¶VꢀPRXQWLQJꢀEUDFNHWꢀLVꢀGHVLJQHGꢀWRꢀPDNHꢀLQVWDOODWLRQꢀRQꢀDꢀZDOOꢀRUꢀDꢀSLSHꢀHDV\ꢁꢀ  
After the unit is attached, its position is fixed with the single bolt. Follow the steps for APC 5M-18 V2  
assembling:  
Step 1.  
Step 2.  
Make sure that the APC unit is powered-off.  
Ground the APC 5M-18 V2 unit. The unit must be properly grounded to protect against  
lightning. The grounding wire must be attached to the grounding stud on the unit (refer  
at the Figure 2 ± APC 5M-18 V2 Overview).  
If the unit is attached to a metal pipe which is earth-grounded, no further grounding is  
required.  
Step 3.  
Attach mounting hardware (item C in the Figure 1 ± APC 5M-18 V2 Package Contents)  
to the unit and tighten with the nut and bolt (items I and J in the Figure 1 ± APC 5M-18  
V2 Package Contents).  
For wall mounting, first attach the mounting bracket to the wall and then connect the unit  
together and tighten the nut and bolt.  
It is recommended not to tighten the unit to its mounting hardware until the alignment  
process of the antenna is complete.  
Step 4.  
For pole mounting attach APC 5M-18 V2 on pole with U bolt (items H and J in the  
Figure 1 ± APC 5M-18 V2 Package Contents) as shown in picture below:  
Step 5.  
Connect Ethernet cable into the APC 5M-18 V2 then insert a rubber gasket (item F in  
the Figure 1 ± APC 5M-18 V2 Package Contents) into CAT5 Ethernet connector gland  
and tighten with gland cap (item E in the Figure 1 ± APC 5M-18 V2 Package Contents)  
as displayed below:  
deliberant  
Page 9  
Quick Installation Guide  
Installation  
Step 6.  
Connect power adapter into PoE injector together with UTP cables as displayed in  
picture below:  
Step 7.  
Step 8.  
Power-up the unit. The green Power LED must be on (refer at the respective section  
LEDs). Depending on link quality, up to four yellow LEDs will switch on indicating that  
link between two units was established successfully.  
After the link was established, align the antenna for the maximum performance. Run  
the Antenna Alignment tool in the Web management interface and move the unit in  
the horizontal and vertical planes until the maximum RSSI visible on the Antenna  
Alignment graph is achieved. After the maximal RSSI is reached, tighten down the unit  
in the optimum position.  
Avoid standing directly in front of an operating antenna while aligning.  
deliberant  
Page 10  
Quick Installation Guide  
Access the APC 5M-18 V2  
ꢀꢂĐĐĞƐƐꢀƚŚĞꢀꢂWꢁꢀϱD-ϭϴꢀsϮ  
The first connection to the APC 5M-18 V2 can be made using a standard Ethernet cable connected  
directly to your PC. See next sections for the instructions on how to access the APC 5M-18 V2  
management interfaces.  
Connection via WEB Browser  
The default IP address of the APC 5M-18 V2 is 192.168.2.66 with a subnet mask of 255.255.255.0.  
Step 1.  
Configure your PC with a static IP address on the 192.168.2.0 subnet with mask  
255.255.255.0. Connect the APC 5M-18 V2 Ethernet interface in to the same physical  
network as your PC. Open the Web browser and type the default IP address of the  
Step 2.  
Step 3.  
Enter the APC 5M-18 V2 administrator login details to access the Web management:  
The default administrator login settings for all APC 5M-18 V2 are:  
Login: admin  
Password: admin01  
After successful administrator log on you will see the main page of the APC 5M-18 V2  
Web management interface. The APC 5M-18 V2 now is ready for configuration. For  
further instructions on Web management refer to the respective document APC 5M-18  
V2 User Guide.  
deliberant  
Page 11  
Quick Installation Guide  
Access the APC 5M-18 V2  
Resetting to Factory Defaults  
APC 5M-18 V2 has the capability of being reset to defaults by pinging the device with a certain packet  
size when the device is booting. During the startup of the device, when the drivers of the ethernet  
interfaces are loaded, the reset daemon is started. The daemon suspends startup process for 3  
seconds and waits for ICMP "echo request" packet of length 369 bytes. If the packet received, the  
reset daemon sets the device to default configuration.  
It is recommended to connect PC to the device via switch, as depending on PC OS  
settings, the ARP table might be flushed during wired link status change (connecting the  
device that will be reset).  
Steps to reset to default settings:  
Step 1.  
Step 2.  
Step 3.  
Step 4.  
Power off the APC 5M-18 V2 device.  
Obtain the device MAC address.  
Connect a PC to the same physical subnet as the device.  
Execute 'arp -s' command to assign the IP address (IP address should be from the  
same subnet as PC) to the device MAC address:  
arp -s <IP address to assign> <device MAC address>  
Note that syntax of MAC address differs depending on OS:  
ƒ
ƒ
Linux OS: AA:BB:CC:DD:EE:FF  
Windows OS: AA-BB-CC-DD-EE-FF  
Step 5.  
Start pinging the APC 5M-18 V2 device:  
For Linux users: ping <IP address> -s 369  
For Windows users: ping <IP address> -l 369 -t -w 200  
Power up device and wait about 30sec or more (depending on device hardware).  
Step 6.  
Step 7.  
Stop pinging the APC 5M-18 V2, and let the device boot as usual. The device should  
start up with factory default settings.  
deliberant  
Page 12  

Sennheiser 300 Iem G2 User Manual
Samsung Sh24tp6 User Manual
Philips Sa2540 User Manual
Panasonic Cs E22jkk User Manual
Motorola Mbp11 User Manual
MAKITA XWT08 User Manual
GE ASH24 User Manual
EMERSON LIEBERT GXT4 8000RT208 User Manual
EMERSON EVC655 User Manual
DELL XPS 8920 User Manual