DBTECHNOLOGIES VIO S218 User Manual

Quick start user manual  
Section 1  
The warnings in this manual must be observed together with the "USER MANUAL - Section 2".  
Le avvertenze nel presente manuale devono essere osservate congiuntamente al “MANUALE D’USO – Sezione 2”.  
Die Warnungen in diesem Handbuch müssen in Verbindung mit der "BEDIENUNGSANLEITUNG - Abschnitt 2" beobachtet  
werden”.  
Les avertissements specifiés dans ce manuel doivent être respectés ainsi que les "CARACTERISTIQUES TECHNIQUES -  
Section 2"  
Las advertencias del presente manual se deben tener en cuenta conjuntamente con las del “MANUAL DEL USUARIO” -  
Sección 2”.  
A.E.B. Industriale Srl Via Brodolini, 8 Località Crespellano 40053 VALSAMOGGIA BOLOGNA (ITALIA)  
3) First switch on  
The product and accessories must be handled  
by trained personnel only! The user is  
required to follow regulations and mandatory  
laws on safety of the country in which the product is  
used. Don’t use handles and/or roping points to hang  
VIO S218!  
The 2 DIGIPRO G4 amplifiers of VIO S218 are controlled  
by a powerful DSP. All the connections and controls are  
in the rear amplifier control panel:  
The subwoofer is supplied with two mounted fuses for  
operation within the 220-240V~ range. If you need to  
operate in the 100-120V~ voltage range:  
.
Disconnect all connections, including the power  
supply  
.
.
Wait 5 minutes  
Replace the fuses with the ones provided in the  
package for the 100-120V~ range  
a) Once you have properly set up the desired  
configuration (see also the VIO S218 complete user  
manual and accessories instructions for further  
information), connect the audio input (1). Set the  
Subwoofer attenuation (3) to the desired level.  
b) Connect the possible output direct link (2), and/or  
HPF Xover output (8). Set the Xover rotary control (9)  
to the correct frequency. This filter acts on internal  
transducers and on HPF Xover output (8), It does not  
affect the link output (2).  
c) Choose the Subwoofer Setup (Polarity and Delay 5,  
6) to obtain the correct behavior. In cardioid  
configuration, please note that the cardioid preset  
switch (7), when active, bypass Polarity and Delay  
controls.  
d) In case of remote control, connect the Data Input  
(10) to the hardware remote controller (RDNet Control  
2 or RDNet Control 8) with cables equipped with  
etherCON connectors. Then connect the Data Output  
(11) to the Data Input (10) of a possible second device,  
and so on. When the RDNet network is on and it has  
recognized the connected device, the LED “Link” (12) is  
on. The other LEDs (12) “Active” start blinking at the  
presence of data transmission, the “Remote Preset  
Active” advise that all the local controls set on the  
amplifier panel (level, DSP presets, etc.) are by-passed  
and controlled remotely by RDNet.  
In remote control it is essential the use of free  
dBTechnologies software:  
dBTechnologies AURORA NET,  
necessary for an in-depth control of different devices  
in remote connection;  
1 – Input (balanced) connector  
2 – Link (balanced) connector  
3 – Subwoofer attenuation rotary control  
4 – Status LEDs (Limiter, Signal, Mute/Protection,  
Ready)  
dBTechnologies Composer,  
necessary for the mechanical safety check in  
installation and for the complete sound system design,  
particularly developed for VIO series.  
5 – Polarity switch  
e) Connect the power supply (15). It is possible to link  
up to 1 VIO S218** at 220V-240V with the related  
mains link connector (16) (see Technical Data for  
further information).  
6 – Delay rotary controls  
7 – Cardioid preset switch  
8 – HPF Xover (balanced) output  
9 – Xover rotary control  
10 – RDNet Data In  
11 – RDNet Data Out  
12 – RDNet status LEDs  
13 – USB Data Service  
14 – Test momentary switch  
15 – Full range Mains input connector  
16 – Mains Link connector  
17 – Mains Fuses  
Check the complete user manual on www.dbtechnologies.com for further  
information about the system and available accessories.  
Scarica il manuale completo da www.dbtechnologies.com per ogni  
ulteriore informazione sul sistema e sugli accessori disponibili.  
Für weitere Informationen und verfügbares Zubehör lesen sie bitte die  
vollständige Bedienungsanleitung unter  
Vérifiez le manuel de l'utilisateur complet sur www.dbtechnologies.com  
pour des informations complémentaires du système et des accessoires  
disponibles.Compruebe el manual de usuario completo sobre  
www.dbtechnologies.com para la información adicional sobre el sistema  
y accesorios disponibles.  
Technical Data  
Processor  
Speaker Type: Active bass-reflex subwoofer  
Controller: DSP, 32 bit  
AD/DA Converter: 24 bit / 96 kHz  
Limiter: Peak, RMS, Thermal  
Acoustical data  
Frequency Response [-6 dB]: 28 Hz – Cut frequency  
(crossover - dependent)  
Controls: Rotary Delay Control (0-9.9 ms, steps: 0.1 ms),  
switches (Link/Xover, Cardioid Preset, System test,  
Polarity), Subwoofer Attenuation, Xover LPF  
Frequency Response [-10 dB (HPF)]: 27 Hz  
Max SPL (1 m): 143 dB  
LF: 2 x 18”, Neodymium  
Input/Output  
LF Voice Coil: 4”  
Mains connections: PowerCON TRUE1 In/link  
®
Crossover freq.: 60 to 110 Hz + full-range  
Directivity: (omnidirectional) Cardioid with DSP  
Maximum number of subwoofer for each daisy chain  
power connection [mains input + mains link]: 1+1 VIO  
S218** (220-240V~), 1+0 VIO S218** (100-120V~)  
Signal Input: (Balanced) 1x IN (female)  
Amplifier  
Amp Technology: Digipro® G4  
Power supply: Full range with PFC  
Amp Class: Class-D  
Signal Out: (Balanced) Link OUT (male) + HPF Xover  
RDNET connectors: Data In / Data Out  
USB connector: standard USB B-type (for SERVICE DATA)  
RMS Power: 3200 W  
Peak Power: 6400 W  
Mechanics  
Cooling: Passive (convection) and internal fan  
Housing: Wooden box/black polyurea finish  
Grille: Full metal (CNC machining)  
Handles: 4 per side  
Operating voltage:  
100-240V~ 50-60 Hz (Full Range)  
Pick points (stack mode): yes on top  
Roping points: 4  
Width: 1300 mm (51.18 in)  
Height: 520 mm (20.47 in)  
Depth: 800 mm (31.50 in)  
Weight: 85.6 kg (188.72 lbs.)  
Scan with  
your QR  
Reader App to  
download the  
complete User  
Manual  
Download the complete user manual on:  
EMI CLASSIFICATION  
According to the standards EN 55103 this equipment is designed and suitable to operate in E5 Electromagnetic environments.  
FCC CLASS A STATEMENT ACCORDING TO TITLE 47, PART 15, SUBPART B, §15.105  
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules.  
These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial  
environment.  
This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may  
cause harmful interference to radio communications.  
Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the  
interference at his own expense.  
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the  
equipment.  
WARNING: This equipment is compliant with Class A of CISPR 32. In a residential environment this equipment may cause radio interference.  
WARNING: Make sure that the loudspeaker is securely installed in a stable position to avoid any injuries or damages to persons or properties.  
For safety reasons do not place one loudspeaker on top of another without proper fastening systems. Before hanging the loudspeaker check  
all the components for damages, deformations, missing or damaged parts that may compromise safety during installation. If you use the  
loudspeakers outdoor avoid spots exposed to bad weather conditions.  
Contact dB Technologies for accessories to be used with speakers. dBTechnologies will not accept any responsibility for damages caused by  
inappropriate accessories or additional devices.  
Features, specification and appearance of products are subject to change without notice.  
dBTechnologies reserves the right to make changes or improvements in design or manufacturing without assuming any obligation to change  
or improve products previously manufactured.  

Xantrex Technology Xc1524 User Manual
Trane 2ttz9 User Manual
Sanyo Ch1222 User Manual
Samsung As09cm2x User Manual
LG 65UH7700 02 User Manual
LG 55UX340H UA User Manual
DELL WLD15 User Manual
CRAFTSMAN 536.885910 User Manual
ASUS ZEN AIO Z272SD User Manual
ASUS VS239H User Manual