Quick start user manual
Section 1
The warnings in this manual must be observed together with the "USER MANUAL - Section 2".
Le avvertenze nel presente manuale devono essere osservate congiuntamente al “MANUALE D’USO – Sezione 2”.
Die Warnungen in diesem Handbuch müssen in Verbindung mit der "BEDIENUNGSANLEITUNG - Abschnitt 2" beobachtet
werden”.
Les avertissements specifiés dans ce manuel doivent être respectés ainsi que les "CARACTERISTIQUES TECHNIQUES -
Section 2"
Las advertencias del presente manual se deben tener en cuenta conjuntamente con las del “MANUAL DEL USUARIO” -
Sección 2”.
A.E.B. Industriale Srl Via Brodolini, 8 Località Crespellano 40053 VALSAMOGGIA BOLOGNA (ITALIA)
3) First switch on
The product and accessories must be handled
by trained personnel only! The user is
required to follow regulations and mandatory
laws on safety of the country in which the product is
used. Don’t use handles and/or roping points to hang
VIO S218!
The 2 DIGIPRO G4 amplifiers of VIO S218 are controlled
by a powerful DSP. All the connections and controls are
in the rear amplifier control panel:
The subwoofer is supplied with two mounted fuses for
operation within the 220-240V~ range. If you need to
operate in the 100-120V~ voltage range:
.
Disconnect all connections, including the power
supply
.
.
Wait 5 minutes
Replace the fuses with the ones provided in the
package for the 100-120V~ range
a) Once you have properly set up the desired
configuration (see also the VIO S218 complete user
manual and accessories instructions for further
information), connect the audio input (1). Set the
Subwoofer attenuation (3) to the desired level.
b) Connect the possible output direct link (2), and/or
HPF Xover output (8). Set the Xover rotary control (9)
to the correct frequency. This filter acts on internal
transducers and on HPF Xover output (8), It does not
affect the link output (2).
c) Choose the Subwoofer Setup (Polarity and Delay 5,
6) to obtain the correct behavior. In cardioid
configuration, please note that the cardioid preset
switch (7), when active, bypass Polarity and Delay
controls.
d) In case of remote control, connect the Data Input
(10) to the hardware remote controller (RDNet Control
2 or RDNet Control 8) with cables equipped with
etherCON connectors. Then connect the Data Output
(11) to the Data Input (10) of a possible second device,
and so on. When the RDNet network is on and it has
recognized the connected device, the LED “Link” (12) is
on. The other LEDs (12) “Active” start blinking at the
presence of data transmission, the “Remote Preset
Active” advise that all the local controls set on the
amplifier panel (level, DSP presets, etc.) are by-passed
and controlled remotely by RDNet.
In remote control it is essential the use of free
dBTechnologies software:
dBTechnologies AURORA NET,
necessary for an in-depth control of different devices
in remote connection;
1 – Input (balanced) connector
2 – Link (balanced) connector
3 – Subwoofer attenuation rotary control
4 – Status LEDs (Limiter, Signal, Mute/Protection,
Ready)
dBTechnologies Composer,
necessary for the mechanical safety check in
installation and for the complete sound system design,
particularly developed for VIO series.
5 – Polarity switch
e) Connect the power supply (15). It is possible to link
up to 1 VIO S218** at 220V-240V with the related
mains link connector (16) (see Technical Data for
further information).
6 – Delay rotary controls
7 – Cardioid preset switch
8 – HPF Xover (balanced) output
9 – Xover rotary control
10 – RDNet Data In
11 – RDNet Data Out
12 – RDNet status LEDs
13 – USB Data Service
14 – Test momentary switch
15 – Full range Mains input connector
16 – Mains Link connector
17 – Mains Fuses
information about the system and available accessories.
ulteriore informazione sul sistema e sugli accessori disponibili.
Für weitere Informationen und verfügbares Zubehör lesen sie bitte die
vollständige Bedienungsanleitung unter
Vérifiez le manuel de l'utilisateur complet sur www.dbtechnologies.com
pour des informations complémentaires du système et des accessoires
disponibles.Compruebe el manual de usuario completo sobre
www.dbtechnologies.com para la información adicional sobre el sistema
y accesorios disponibles.
Technical Data
Processor
Speaker Type: Active bass-reflex subwoofer
Controller: DSP, 32 bit
AD/DA Converter: 24 bit / 96 kHz
Limiter: Peak, RMS, Thermal
Acoustical data
Frequency Response [-6 dB]: 28 Hz – Cut frequency
(crossover - dependent)
Controls: Rotary Delay Control (0-9.9 ms, steps: 0.1 ms),
switches (Link/Xover, Cardioid Preset, System test,
Polarity), Subwoofer Attenuation, Xover LPF
Frequency Response [-10 dB (HPF)]: 27 Hz
Max SPL (1 m): 143 dB
LF: 2 x 18”, Neodymium
Input/Output
LF Voice Coil: 4”
Mains connections: PowerCON TRUE1 In/link
®
Crossover freq.: 60 to 110 Hz + full-range
Directivity: (omnidirectional) Cardioid with DSP
Maximum number of subwoofer for each daisy chain
power connection [mains input + mains link]: 1+1 VIO
S218** (220-240V~), 1+0 VIO S218** (100-120V~)
Signal Input: (Balanced) 1x IN (female)
Amplifier
Amp Technology: Digipro® G4
Power supply: Full range with PFC
Amp Class: Class-D
Signal Out: (Balanced) Link OUT (male) + HPF Xover
RDNET connectors: Data In / Data Out
USB connector: standard USB B-type (for SERVICE DATA)
RMS Power: 3200 W
Peak Power: 6400 W
Mechanics
Cooling: Passive (convection) and internal fan
Housing: Wooden box/black polyurea finish
Grille: Full metal (CNC machining)
Handles: 4 per side
Operating voltage:
100-240V~ 50-60 Hz (Full Range)
Pick points (stack mode): yes on top
Roping points: 4
Width: 1300 mm (51.18 in)
Height: 520 mm (20.47 in)
Depth: 800 mm (31.50 in)
Weight: 85.6 kg (188.72 lbs.)
Scan with
your QR
Reader App to
download the
complete User
Manual
Download the complete user manual on:
EMI CLASSIFICATION
According to the standards EN 55103 this equipment is designed and suitable to operate in E5 Electromagnetic environments.
FCC CLASS A STATEMENT ACCORDING TO TITLE 47, PART 15, SUBPART B, §15.105
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial
environment.
This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may
cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the
interference at his own expense.
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the
equipment.
WARNING: This equipment is compliant with Class A of CISPR 32. In a residential environment this equipment may cause radio interference.
WARNING: Make sure that the loudspeaker is securely installed in a stable position to avoid any injuries or damages to persons or properties.
For safety reasons do not place one loudspeaker on top of another without proper fastening systems. Before hanging the loudspeaker check
all the components for damages, deformations, missing or damaged parts that may compromise safety during installation. If you use the
loudspeakers outdoor avoid spots exposed to bad weather conditions.
Contact dB Technologies for accessories to be used with speakers. dBTechnologies will not accept any responsibility for damages caused by
inappropriate accessories or additional devices.
Features, specification and appearance of products are subject to change without notice.
dBTechnologies reserves the right to make changes or improvements in design or manufacturing without assuming any obligation to change
or improve products previously manufactured.
|