York Yhjf18 User Manual

510667-YTG-A-0409  
DESCRIPTION  
The heat pump condensing unit is the outdoor part of a versatile  
system of heating and air conditioning. It is designed to be cus-  
tom-matched with one of UPG’s complete line of evaporator  
sections, with each serving a specific function. Matching Air  
Handlers are available for upflow, downflow, or horizontal appli-  
cations to provide a complete system. Electric Heaters are  
available, if required. Add-on coils are available for use with  
upflow, downflow, or horizontal furnaces and air handlers. Many  
matches meet Federal Tax Rebate program.  
WARRANTY  
Single Phase Units:  
TECHNICAL GUIDE  
5-year limited parts warranty.  
SPLIT-SYSTEM  
HEAT PUMPS  
10-year limited compressor warranty.  
FEATURES  
14.5 SEER – R-410A  
QUALITY CONDENSER COILS - The coil is constructed of  
copper tubing and enhanced aluminum fins for increased  
efficiency and corrosion protection.  
MODELS:  
PROTECTED COMPRESSOR - The complete scroll com-  
pressor line is internally protected against high pressure,  
temperature, and externally by a factory installed high pres-  
sure switch. This is accomplished by the simultaneous oper-  
ation of high pressure relief valve and a temperature sensor  
which protects the compressor if undesirable operating con-  
ditions occur. A liquid line filter-drier further protects the com-  
pressor.  
YHJF18 THRU 60  
(1.5 THRU 5 NOMINAL TONS, 1 PHASE)  
DURABLE FINISH - The cabinet is made of pre-painted  
steel. The pre-treated galvanized steel provides a better  
paint to steel bond, which resists corrosion and rust creep.  
Special primer formulas and matted-textured finish insure  
less fading when exposed to sunlight.  
LOWER INSTALLED COST - Installation time and costs are  
reduced by easy power and control wiring connections.  
Available in sweat connect models only. The unit contains  
enough refrigerant for matching indoor coils and 15 feet of  
interconnecting piping. The small base dimension means  
less space is required on the ground or roof.  
TOP DISCHARGE - The warm air from the top mounted fan  
is blown up away from the structure and any landscaping.  
This allows compact location on multi-unit applications.  
SWEPT FAN BLADE SOUND JACKET - The upward air  
flow carries the normal operating noise away from the living  
area. The rigid top panel effectively isolates any motor  
sound. Isolator mounted compressor and the rippled fins of  
the condenser coil muffle the normal fan motor and compres-  
sor operating sounds. The swept wing fan blade and com-  
pressor sound jacket futher reduce noise levels.  
ISO 9001  
Certified Quality  
Management System  
LOW MAINTENANCE - Long life permanently lubricated  
motor-bearings need no annual servicing.  
EASY SERVICE ACCESS - Fully exposed refrigerant con-  
nections, and a single panel covering the electrical controls  
make for easy servicing of the unit.  
LISTED  
SECURED SERVICE VALVES - Secured re-usable service  
valves are provided on both the liquid and vapor sweat con-  
nections for ease of evacuating and charging.  
Due to continuous product improvement, specifications  
are subject to change without notice.  
U.L. and C.U.L. listed - approved for outdoor application.  
Agency Listed - U.L. and C.U.L. listed - approved for out-  
door application. The unit is certified in accordance with the  
Unitary Small Equipment cerification program, which is  
based on ARI Standard 210/240.  
Additional rating information can be found at  
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE  
510667-YTG-A-0409  
System Charge for Various Matched Systems  
YHJF18  
S41S1  
YHJF24  
S41S1  
YHJF30  
S41S1  
YHJF36  
S41S1  
YHJF42  
S41S1  
YHJF48  
YHJF60  
S41S1  
Outdoor Unit  
S41S1  
1TVM4J1  
14 - 2  
Required Orifice or TXV 1,2  
Factory Charge, lbs-oz  
.051/1TVM4F1 .059/1TVM4G1 .063/1TVM4G1 .071/1TVM4H1 .075/1TVM4J1  
1TVM4K1  
14 - 2  
6 - 15  
7 - 14  
9 - 14  
10 - 9  
10 - 9  
Indoor Coil3,4  
FC/MC/PC/UC32  
FC/MC/PC/UC35  
FC/MC/PC/UC37  
FC/MC/PC/UC43  
FC/PC62D3X  
AHX30  
Additional Charge, Oz  
.051 + 0  
.051 + 0  
.051 + 13  
.051 + 13  
.059 + 0  
.059 + 0  
.059 + 12  
.059 + 12  
.063 + 0  
.063 + 0  
.071 + 0  
.071 + 0  
.075 + 0  
TXV + 0  
TXV + 0  
.051 + 0  
.051 + 13  
.059 + 0  
.059 + 12  
AHX36  
.063 + 0  
.071 + 0  
AHX60  
.075 + 0  
TXV + 0  
TXV + 0  
AV36  
.051 + 13  
.051 + 0  
.051 + 0  
.059 + 12  
.059 + 0  
.059 + 0  
.063 + 0  
.071 + 0  
F6FP030H06  
F6FP036H06  
F6FP042H06  
F6FP060H06  
FOOTNOTES:  
.063 + 3  
.063 + 3  
.075 + 0  
TXV + 0  
TXV + 0  
1. For applications requiring a TXV use 1TVM900 series kit.  
2. Approved orifice shipped with outdoor unit.  
3. Systems matched with furnace or air handlers not equipped with blower-off delays may require blower Time Delay Kit 2FD06700224.  
4. PC coils cannot be used in downflow or horizontal applications. FC coils cannot be used in horizontal applications.  
PROCEDURES:  
1. Unit factory charge listed on the unit nameplate includes refrigerant for the condenser, the smallest evaporator and 15 feet of interconnecting  
line tubing.  
2. Verify the TXV and additional charge required for specific evaporator coil in the system using the above table.  
3. Additional charge for the amount of interconnecting line tubing greater than 15 feet at the rate specified in Physical and Electrical Data Table.  
4. For orifice or TXV matches requiring additional charge, the refrigerant needs to be weighed in for specific coil match and lineset length.  
5. Permanently mark the unit nameplate with the total system charge. Total System Charge = Base Charge (as shipped) + adder for evaporator +  
adder for line set.  
Johnson Controls Unitary Products  
3
510667-YTG-A-0409  
COOLING CAPACITY - With Air Handler Coils  
AIR HANDLER  
COOLING  
NET MBH  
UNIT  
COIL  
MODEL1  
STAGE  
RATED  
CFM  
MODEL  
MODEL  
W
SEER  
EER  
TOTAL  
SENS.  
14.5 SEER HP WITH MV - VARIABLE SPEED  
MV12B  
MV12B  
MV12B  
MV12B  
MV12B  
MV16C  
MV12B  
MV16C  
MV20D  
MV20D  
17  
17  
17  
17  
17  
21  
17  
21  
24  
24  
FC/MC35B  
FC/MC43B  
FC/MC35B  
FC/MC43B  
FC/MC43B  
FC/MC43C  
FC/MC43B  
FC/MC43C  
FC/MC62D  
FC/MC62D  
1
600  
600  
800  
18.0  
18.0  
22.8  
23.4  
29.0  
29.0  
35.4  
35.2  
40.0  
48.0  
48.0  
13.0  
13.3  
17.2  
18.0  
21.6  
21.6  
26.6  
26.4  
30.8  
36.2  
31.0  
15.00  
15.00  
15.00  
15.00  
15.00  
15.00  
14.35  
14.50  
14.50  
15.00  
12.50  
12.50  
12.50  
12.50  
12.50  
12.50  
12.00  
12.00  
12.00  
12.50  
21.55  
YHJF18S41S1  
YHJF24S41S1  
YHJF30S41S1  
YHJF36S41S1  
800  
1000  
1000  
1225  
1200  
1400  
1630  
1160  
YHJF42S41S1  
YHJF48S41S1  
YHJF60S41S1  
MV20D  
24  
FC/MC62D  
14.50  
2
1855  
57.0  
40.5  
12.00  
14.5 SEER HP WITH AV / SV / F*FV - VARIABLE SPEED  
YHJF18S41S1  
YHJF24S41S1  
YHJF30S41S1  
YHJF36S41S1  
AV*36  
AV*36  
AV*36  
AV*36  
21  
21  
21  
21  
630  
725  
960  
18.0  
22.8  
29.2  
35.4  
13.3  
16.8  
21.8  
26.4  
15.00  
15.00  
15.00  
14.50  
12.50  
12.50  
12.50  
12.00  
1190  
14.5 SEER HP WITH AHP / SHP / AHX / F*FP  
YHJF18S41S1  
YHJF24S41S1  
AHX30  
AHX30  
F6FP030  
F6FP036  
AHX36  
AHX36  
F6FP042  
AHX36  
AHX42  
F6FP042  
AHX60  
F6FP060  
AHX60  
F6FP060  
17  
17  
17  
21  
21  
21  
21  
21  
21  
24  
24  
24  
24  
24  
1
640  
800  
850  
855  
820  
1030  
1065  
1210  
1190  
1290  
1355  
1475  
1570  
1570  
1160  
18.0  
22.8  
22.8  
22.8  
23.0  
29.4  
29.4  
35.4  
35.8  
36.0  
40.0  
40.5  
48.0  
48.0  
47.5  
13.3  
17.1  
17.3  
17.4  
17.4  
22.2  
22.2  
26.6  
26.8  
27.6  
30.2  
31.4  
35.6  
35.6  
30.5  
15.00  
15.00  
14.50  
15.00  
15.00  
15.00  
15.00  
14.50  
15.00  
15.00  
14.50  
14.50  
15.00  
15.00  
12.50  
12.50  
12.00  
12.50  
12.50  
12.50  
12.50  
12.00  
12.50  
12.50  
12.00  
12.00  
12.50  
12.50  
21.20  
YHJF30S41S1  
YHJF36S41S1  
YHJF42S41S1  
YHJF48S41S1  
YHJF60S41S1  
AHX60  
24  
14.50  
2
1855  
57.0  
40.5  
12.00  
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210.  
Cooling MBH based on 8°F entering air temperature, 50% RH, and rated air flow.  
EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.  
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power  
input in watt-hours during the same period.  
1. MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.  
— = Not applicable.  
4
Johnson Controls Unitary Products  
510667-YTG-A-0409  
COOLING CAPACITY - With High Efficiency Motor Furnaces  
COOLING  
Net MBH  
UNIT  
MODEL  
FURNACE  
MODEL  
COIL  
W
STAGE  
RATED  
CFM  
MODEL1  
SEER  
EER  
TOTAL  
SENS.  
14.5 SEER HP WITH VARIABLE SPEED FURNACES2  
T*(8,L)X*A12  
Y*(8,L)(C,V)*A12  
Y*(8,L)(C,V)*B12  
Y*(8,L)(C,V)*C16  
Y*9(C,V)*B12  
Y*9(C,V)*C16  
Y*(8,L)(C,V)*A12  
Y*(8,L)(C,V)*B12  
T*(8,L)X*A12  
T*(8,L)X*B12  
T*(8,L)X*C16  
T*(8,L)X*C20  
T*9X*B12  
FC/MC/PC32A  
FC/MC/PC32A  
FC/MC/PC35B  
FC/MC/PC35C  
FC/MC/PC35B  
FC/MC/PC35C  
FC/MC/PC37A  
FC/MC/PC43B  
FC/MC/PC32A  
FC/MC/PC35B  
FC/MC/PC35C  
FC/MC/PC35C  
FC/MC/PC35B  
FC/MC/PC35C  
FC/MC/PC35C  
FC/MC/PC37A  
FC/MC/PC43B  
FC/MC/PC43C  
FC/MC/PC43B  
FC/MC/PC43C  
FC/MC/PC43C  
FC/MC/PC32A  
FC/MC/PC35B  
FC/MC/PC35C  
FC/MC/PC35C  
FC/MC/PC35B  
FC/MC/PC35C  
FC/MC/PC35C  
FC/MC/PC37A  
FC/MC/PC43B  
FC/MC/PC43C  
FC/MC/PC43C  
FC/MC/PC43B  
FC/MC/PC43C  
FC/MC/PC43C  
FC/MC/PC37A  
FC/MC/PC43B  
FC/MC/PC43C  
FC/MC/PC43B  
FC/MC/PC43C  
FC/MC/PC37A  
FC/MC/PC43B  
FC/MC/PC43C  
FC/MC/PC43C  
FC/MC/PC43B  
FC/MC/PC43C  
FC/MC/PC43C  
14  
14  
17  
21  
17  
21  
14  
17  
14  
17  
21  
21  
17  
21  
21  
14  
17  
21  
17  
21  
21  
14  
17  
21  
21  
17  
21  
21  
14  
17  
21  
21  
17  
21  
21  
14  
17  
21  
17  
21  
14  
17  
21  
21  
17  
21  
21  
590  
590  
650  
600  
570  
645  
625  
560  
800  
850  
865  
865  
785  
765  
825  
840  
865  
855  
800  
785  
790  
775  
760  
855  
740  
815  
865  
755  
805  
760  
875  
760  
800  
810  
875  
1095  
1105  
955  
1095  
1055  
980  
990  
990  
1000  
1035  
1030  
995  
18.0  
18.0  
18.0  
18.0  
18.0  
18.0  
18.0  
18.0  
23.0  
23.0  
23.2  
23.2  
23.0  
23.0  
23.0  
23.4  
23.4  
23.4  
23.4  
23.2  
23.2  
22.8  
22.6  
23.0  
22.6  
22.8  
23.2  
22.6  
23.2  
22.8  
23.4  
23.0  
23.2  
23.4  
23.4  
29.4  
29.6  
29.2  
29.4  
29.4  
28.6  
28.8  
29.0  
29.0  
29.0  
29.2  
29.0  
13.0  
13.0  
13.4  
13.0  
13.0  
13.4  
13.3  
12.8  
17.3  
17.8  
18.0  
18.1  
17.3  
17.3  
17.2  
18.0  
18.1  
18.1  
18.0  
17.5  
17.4  
17.1  
16.7  
17.7  
16.6  
17.1  
18.2  
16.7  
17.9  
17.0  
18.5  
17.1  
17.9  
18.0  
18.4  
23.0  
23.2  
21.6  
23.0  
22.6  
21.4  
21.4  
21.6  
21.6  
22.0  
22.2  
21.6  
15.00  
15.00  
15.00  
15.00  
15.00  
15.00  
15.00  
15.00  
15.00  
15.00  
15.00  
15.00  
15.00  
15.00  
15.00  
15.00  
15.00  
15.00  
15.00  
15.00  
15.00  
14.50  
15.00  
15.00  
15.00  
14.50  
15.00  
15.00  
15.00  
15.00  
15.00  
15.00  
15.00  
15.00  
15.00  
15.00  
15.00  
15.00  
15.00  
15.00  
14.50  
15.00  
15.00  
15.00  
14.50  
15.00  
15.00  
12.50  
12.50  
12.50  
12.50  
12.50  
12.50  
12.50  
12.50  
12.50  
12.50  
12.50  
12.50  
12.50  
12.50  
12.50  
12.50  
12.50  
12.50  
12.50  
12.50  
12.50  
12.00  
12.50  
12.50  
12.50  
12.00  
12.50  
12.50  
12.50  
12.50  
12.50  
12.50  
12.50  
12.50  
12.50  
12.50  
12.50  
12.50  
12.50  
12.50  
12.00  
12.50  
12.50  
12.50  
12.00  
12.50  
12.50  
YHJF18S41S1  
T*9X*C16  
T*9X*C20  
T*(8,L)X*A12  
T*(8,L)X*B12  
T*(8,L)X*C16  
T*9X*B12  
T*9X*C16  
T*9X*C20  
YHJF24S41S1  
Y*(8,L)(C,V)*A12  
Y*(8,L)(C,V)*B12  
Y*(8,L)(C,V)*C16  
Y*(8,L)(C,V)*C20  
Y*9(C,V)*B12  
Y*9(C,V)*C16  
Y*9(C,V)*C20  
Y*(8,L)(C,V)*A12  
Y*(8,L)(C,V)*B12  
Y*(8,L)(C,V)*C16  
Y*(8,L)(C,V)*C20  
Y*9(C,V)*B12  
Y*9(C,V)*C16  
Y*9(C,V)*C20  
T*(8,L)X*A12  
T*(8,L)X*B12  
T*(8,L)X*C16  
T*9X*B12  
T*9X*C16  
Y*(8,L)(C,V)*A12  
Y*(8,L)(C,V)*B12  
Y*(8,L)(C,V)*C16  
Y*(8,L)(C,V)*C20  
Y*9(C,V)*B12  
Y*9(C,V)*C16  
Y*9(C,V)*C20  
YHJF30S41S1  
For Notes See Page 6.  
Johnson Controls Unitary Products  
5
510667-YTG-A-0409  
COOLING CAPACITY - With High Efficiency Motor Furnaces (Continued)  
COOLING  
Net MBH  
UNIT  
MODEL  
FURNACE  
MODEL  
COIL  
W
STAGE  
RATED  
CFM  
MODEL1  
SEER  
EER  
TOTAL  
SENS.  
14.5 SEER HP WITH VARIABLE SPEED FURNACES2  
T*(8,L)X*A12  
T*(8,L)X*B12  
T*(8,L)X*C16  
T*(8,L)X*C20  
T*9X*B12  
FC/MC/PC37A  
FC/MC/PC43B  
FC/MC/PC43C  
FC/MC/PC43C  
FC/MC/PC43B  
FC/MC/PC43C  
FC/MC/PC43C  
FC/MC/PC43C  
FC/MC/PC43C  
FC/MC/PC43C  
FC/MC/PC43C  
FC/MC62D  
14  
17  
21  
21  
17  
21  
21  
21  
21  
21  
21  
21  
21  
21  
21  
24  
21  
21  
21  
24  
21  
21  
21  
21  
24  
21  
21  
21  
21  
24  
1
2
1290  
1300  
1175  
1250  
1270  
1260  
1185  
1205  
1190  
1240  
1200  
1360  
1485  
1460  
1460  
1425  
1420  
1410  
1445  
1455  
1610  
1665  
1550  
1595  
1610  
1635  
1615  
1590  
1655  
1630  
835  
35.8  
35.8  
35.4  
36.0  
35.8  
36.0  
35.2  
35.2  
35.2  
35.6  
35.2  
40.5  
40.5  
40.0  
40.5  
40.5  
40.0  
40.5  
40.0  
40.0  
48.0  
48.0  
48.0  
48.0  
48.0  
48.0  
48.0  
47.5  
47.5  
47.5  
44.0  
57.0  
27.4  
27.4  
26.4  
27.4  
27.4  
27.4  
26.4  
26.4  
26.4  
27.2  
26.4  
31.0  
31.8  
30.8  
31.0  
31.0  
30.8  
30.8  
30.6  
30.6  
36.2  
36.2  
36.0  
36.2  
36.0  
36.0  
36.0  
36.0  
35.8  
35.8  
27.0  
39.5  
14.50  
14.50  
15.00  
15.00  
14.50  
14.50  
14.50  
14.50  
14.50  
14.20  
14.35  
15.00  
15.00  
14.50  
14.50  
14.50  
14.40  
14.50  
14.05  
14.25  
14.50  
14.50  
14.50  
14.50  
14.50  
14.50  
14.50  
14.35  
14.05  
14.25  
12.00  
12.00  
12.50  
12.50  
12.00  
12.00  
12.00  
12.00  
12.00  
12.00  
12.00  
12.50  
12.50  
12.00  
12.00  
12.00  
12.00  
12.00  
11.90  
12.00  
12.00  
12.00  
12.00  
12.00  
12.00  
12.00  
12.00  
12.00  
12.00  
12.00  
20.25  
12.00  
YHJF36S41S1  
T*9X*C16  
T*9X*C20  
Y*(8,L)(C,V)*C16  
Y*(8,L)(C,V)*C20  
Y*9(C,V)*C16  
Y*9(C,V)*C20  
T*(8,L)X*C16  
T*(8,L)X*C20  
T*9X*C16  
FC/MC62D  
FC/MC62D  
T*9X*C20  
FC/MC62D  
YHJF42S41S1  
T*9X*D20  
FC/MC62D  
Y*(8,L)(C,V)*C16  
Y*(8,L)(C,V)*C20  
Y*9(C,V)*C20  
Y*9(C,V)*D20  
T*(8,L)X*C16  
T*(8,L)X*C20  
T*9X*C16  
FC/MC62D  
FC/MC62D  
FC/MC62D  
FC/MC62D  
FC/MC62D  
FC/MC62D  
FC/MC62D  
T*9X*C20  
FC/MC62D  
T*9X*D20  
FC/MC62D  
YHJF48S41S1  
Y*(8,L)(C,V)*C16  
Y*(8,L)(C,V)*C20  
Y*9(C,V)*C16  
Y*9(C,V)*C20  
Y*9(C,V)*D20  
FC/MC62D  
FC/MC62D  
FC/MC62D  
FC/MC62D  
FC/MC62D  
T*(8,L)X*C20  
T*9X*C20  
FC/MC62D  
FC/MC62D  
FC/MC62D  
FC/MC62D  
FC/MC62D  
FC/MC62D  
21  
21  
24  
21  
21  
24  
14.50  
14.50  
14.50  
14.50  
14.50  
14.50  
1665  
1
2
1
2
1
2
1
2
1
2
1220  
1595  
1240  
1645  
1015  
1615  
1040  
1655  
1085  
1630  
48.5  
56.5  
48.5  
56.5  
46.0  
56.5  
46.5  
56.0  
47.0  
56.0  
31.6  
38.5  
31.8  
39.0  
29.2  
38.5  
29.4  
38.5  
29.8  
38.5  
21.10  
12.00  
21.30  
12.00  
20.65  
12.00  
20.55  
12.00  
20.65  
12.00  
T*9X*D20  
YHJF60S41S1  
Y*(8,L)(C,V)*C20  
Y*9(C,V)*C20  
Y*9(C,V)*D20  
1. MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.  
2. Variable speed furnaces have B.O.D (Blower on Delay) standard.  
6
Johnson Controls Unitary Products  
510667-YTG-A-0409  
\
HEATING PERFORMANCE - With Air Handler  
ARI HEATING2  
MBH  
COIL1  
UNIT  
AIR  
47F  
COP  
17F  
COP  
HSPF  
STD  
MODEL*  
HANDLER  
MODEL  
MBH  
KW  
KW  
14.5 SEER HP WITH MV - VARIABLE SPEED  
MV12B  
MV12B  
MV12B  
MV12B  
MV12B  
MV16C  
MV12B  
MV16C  
MV20D  
MV20D  
FC/MC35B  
FC/MC43B  
FC/MC35B  
FC/MC43B  
FC/MC43B  
FC/MC43C  
FC/MC43B  
FC/MC43C  
FC/MC62D  
FC/MC62D  
18.0  
18.0  
22.2  
22.2  
30.0  
30.0  
36.0  
36.0  
40.5  
48.0  
3.76  
3.90  
3.68  
3.82  
3.88  
3.92  
3.74  
3.74  
4.02  
3.82  
1.40  
1.35  
1.77  
1.70  
2.27  
2.24  
2.82  
2.82  
2.95  
3.68  
11.0  
10.9  
14.9  
14.9  
18.8  
18.8  
24.4  
24.2  
26.0  
31.8  
2.48  
2.56  
2.46  
2.54  
2.68  
2.70  
2.52  
2.52  
2.76  
2.60  
1.30  
1.25  
1.77  
1.72  
2.06  
2.04  
2.84  
2.81  
2.76  
3.58  
8.50  
8.50  
8.50  
8.50  
9.00  
9.00  
8.20  
9.00  
9.00  
9.00  
YHJF18S41S1  
YHJF24S41S1  
YHJF30S41S1  
YHJF36S41S1  
YHJF42S41S1  
YHJF48S41S1  
14.5 SEER HP WITH AV / SV / F*FV - VARIABLE SPEED  
YHJF18S41S1  
YHJF24S41S1  
YHJF30S41S1  
YHJF36S41S1  
AV*36  
AV*36  
AV*36  
AV*36  
18.0  
22.0  
29.8  
36.0  
3.98  
3.70  
3.98  
3.78  
1.33  
1.74  
2.19  
2.79  
10.8  
14.8  
18.6  
24.2  
2.62  
2.50  
2.74  
2.54  
1.21  
1.73  
1.99  
2.79  
8.50  
8.50  
9.00  
9.00  
14.5 SEER HP WITH AHP / SHP / AHX / F*FP  
YHJF18S41S1  
YHJF24S41S1  
AHX30  
AHX30  
18.0  
22.2  
22.2  
22.2  
22.4  
30.0  
30.0  
36.0  
36.0  
36.0  
40.5  
41.0  
48.0  
48.0  
3.88  
3.64  
3.64  
3.68  
3.70  
4.00  
4.00  
3.82  
3.84  
3.88  
4.00  
4.04  
3.82  
3.82  
1.36  
1.79  
1.79  
1.77  
1.77  
2.20  
2.20  
2.76  
2.75  
2.72  
2.97  
2.97  
3.68  
3.68  
10.9  
13.7  
15.1  
15.0  
15.1  
18.7  
18.7  
24.2  
22.2  
24.4  
26.0  
26.2  
31.6  
31.6  
2.52  
2.42  
2.42  
2.46  
2.46  
2.76  
2.76  
2.56  
2.56  
2.60  
2.74  
2.74  
2.60  
2.60  
1.27  
1.66  
1.83  
1.79  
1.80  
1.99  
1.99  
2.77  
2.54  
2.75  
2.78  
2.80  
3.56  
3.56  
8.50  
8.50  
8.20  
8.50  
8.50  
9.00  
9.00  
9.00  
9.00  
9.00  
9.00  
9.00  
9.00  
9.00  
F6FP030  
F6FP036  
AHX36  
AHX36  
YHJF30S41S1  
YHJF36S41S1  
YHJF42S41S1  
F6FP042  
AHX36  
AHX42  
F6FP042  
AHX60  
F6FP060  
AHX60  
YHJF48S41S1  
F6FP060  
See notes below.  
HEATING CAPACITY - With Air Handler Coils  
HEATING2  
NET MBH  
COIL1  
UNIT  
MODEL  
AIR  
HANDLER  
RATED  
CFM  
MODEL  
STAGE  
HSPF  
COP @ 47  
47 OD  
17 OD  
14.5 SEER HP WITH MV - VARIABLE SPEED  
1
2
2
1160  
1855  
1160  
43.0  
57.0  
54.9  
YHJF60S41S1  
YHJF60S41S1  
MV20D  
AHX60  
FC/MC62D  
40.5  
39.0  
9.00  
8.85  
3.66  
3.04  
14.5 SEER HP WITH AHX  
1
2
2
1160  
1855  
1170  
43.1  
58.0  
57.5  
40.0  
40.0  
9.00  
8.90  
3.72  
3.24  
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210.  
Cooling MBH based on 8°F entering air temperature, 50% RH, and rated air flow.  
EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.  
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power  
input in watt-hours during the same period.  
1. Rated CFM same as for cooling.  
2. Heating MBH based on ARI standards of 70° DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and no  
supplemental electric heat operation.  
CP equals MBH output divided by (total KW input x 3.412).  
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the  
total electric power input during the same period.  
— = Not Applicable.  
Johnson Controls Unitary Products  
7
510667-YTG-A-0409  
HEATING CAPACITY - With High Efficiency Motor Furnaces  
ARI HEATING2  
MBH  
COIL1  
MODEL  
FURNACE  
MODEL  
MODEL  
47F  
COP  
17F  
HSPF  
STD  
MBH  
KW  
COP  
KW  
14.5 SEER HP WITH VARIABLE SPEED FURNACES3  
T*(8,L)X*A12  
Y*(8,L)(C,V)*A12  
Y*(8,L)(C,V)*B12  
Y*(8,L)(C,V)*C16  
Y*9(C,V)*B12  
Y*9(C,V)*C16  
Y*(8,L)(C,V)*A12  
Y*(8,L)(C,V)*B12  
T*(8,L)X*A12  
T*(8,L)X*B12  
T*(8,L)X*C16  
T*(8,L)X*C20  
T*9X*B12  
FC/MC/PC32A  
FC/MC/PC32A  
FC/MC/PC35B  
FC/MC/PC35C  
FC/MC/PC35B  
FC/MC/PC35C  
FC/MC/PC37A  
FC/MC/PC43B  
FC/MC/PC32A  
FC/MC/PC35B  
FC/MC/PC35C  
FC/MC/PC35C  
FC/MC/PC35B  
FC/MC/PC35C  
FC/MC/PC35C  
FC/MC/PC37A  
FC/MC/PC43B  
FC/MC/PC43C  
FC/MC/PC43B  
FC/MC/PC43C  
FC/MC/PC43C  
FC/MC/PC32A  
FC/MC/PC35B  
FC/MC/PC35C  
FC/MC/PC35C  
FC/MC/PC35B  
FC/MC/PC35C  
FC/MC/PC35C  
FC/MC/PC37A  
FC/MC/PC43B  
FC/MC/PC43C  
FC/MC/PC43C  
FC/MC/PC43B  
FC/MC/PC43C  
FC/MC/PC43C  
FC/MC/PC37A  
FC/MC/PC43B  
FC/MC/PC43C  
FC/MC/PC43B  
FC/MC/PC43C  
FC/MC/PC37A  
FC/MC/PC43B  
FC/MC/PC43C  
FC/MC/PC43C  
FC/MC/PC43B  
FC/MC/PC43C  
FC/MC/PC43C  
17.9  
18.0  
18.0  
18.0  
18.0  
18.0  
18.0  
18.0  
22.0  
22.0  
22.0  
22.0  
22.0  
22.0  
22.2  
22.2  
22.0  
22.0  
22.2  
22.0  
22.0  
22.2  
22.0  
22.2  
21.8  
22.2  
22.2  
22.0  
22.4  
22.0  
22.2  
22.0  
22.2  
22.2  
22.4  
30.0  
30.0  
30.0  
30.0  
30.0  
30.0  
30.0  
30.0  
30.0  
30.0  
30.0  
30.0  
3.84  
3.76  
3.84  
3.82  
3.80  
3.84  
3.90  
3.80  
3.72  
3.74  
3.76  
3.76  
3.72  
3.78  
3.72  
3.88  
3.88  
3.88  
3.88  
3.80  
3.74  
3.62  
3.56  
3.68  
3.60  
3.64  
3.70  
3.58  
3.76  
3.68  
3.84  
3.72  
3.78  
3.82  
3.82  
4.02  
4.00  
3.96  
3.98  
3.96  
3.80  
3.86  
3.92  
3.94  
3.84  
3.90  
3.90  
1.37  
1.40  
1.37  
1.38  
1.39  
1.37  
1.35  
1.39  
1.73  
1.72  
1.71  
1.71  
1.73  
1.71  
1.75  
1.68  
1.66  
1.66  
1.68  
1.70  
1.72  
1.80  
1.81  
1.77  
1.77  
1.79  
1.76  
1.80  
1.75  
1.75  
1.69  
1.73  
1.72  
1.70  
1.72  
2.19  
2.20  
2.22  
2.21  
2.22  
2.31  
2.28  
2.24  
2.23  
2.29  
2.25  
2.25  
10.8  
11.0  
10.9  
10.9  
10.9  
10.9  
10.9  
10.8  
14.8  
14.8  
14.8  
14.8  
14.8  
14.7  
14.9  
14.8  
14.8  
14.8  
14.8  
14.8  
14.9  
15.0  
14.9  
14.9  
14.8  
15.0  
15.0  
14.8  
15.0  
14.9  
14.9  
14.8  
15.0  
14.9  
14.9  
18.9  
18.9  
18.6  
18.8  
18.8  
19.1  
18.9  
18.7  
18.7  
19.0  
18.9  
18.8  
2.54  
2.48  
2.50  
2.52  
2.50  
2.50  
2.58  
2.52  
2.48  
2.48  
2.50  
2.48  
2.48  
2.50  
2.48  
2.56  
2.58  
2.58  
2.56  
2.54  
2.50  
2.42  
2.40  
2.44  
2.42  
2.42  
2.44  
2.42  
2.50  
2.46  
2.52  
2.50  
2.52  
2.52  
2.52  
2.74  
2.72  
2.74  
2.72  
2.72  
2.62  
2.66  
2.70  
2.72  
2.64  
2.68  
2.70  
1.25  
1.30  
1.28  
1.27  
1.28  
1.28  
1.24  
1.26  
1.75  
1.75  
1.73  
1.75  
1.75  
1.72  
1.76  
1.69  
1.68  
1.68  
1.69  
1.71  
1.75  
1.82  
1.82  
1.79  
1.79  
1.82  
1.80  
1.79  
1.76  
1.77  
1.73  
1.73  
1.74  
1.73  
1.73  
2.02  
2.04  
1.99  
2.03  
2.03  
2.14  
2.08  
2.03  
2.01  
2.11  
2.07  
2.04  
9.00  
8.50  
8.50  
8.50  
8.50  
8.50  
8.50  
8.50  
8.50  
8.50  
8.50  
8.50  
8.50  
9.00  
8.50  
8.50  
8.50  
8.50  
8.50  
9.00  
8.50  
8.50  
8.50  
8.50  
8.50  
8.50  
8.50  
8.50  
8.50  
8.50  
8.50  
8.50  
8.50  
8.50  
8.50  
9.00  
9.00  
9.00  
9.00  
9.00  
8.50  
8.50  
9.00  
9.00  
8.50  
9.00  
9.00  
YHJF18S41S1  
T*9X*C16  
T*9X*C20  
T*(8,L)X*A12  
T*(8,L)X*B12  
T*(8,L)X*C16  
T*9X*B12  
T*9X*C16  
T*9X*C20  
YHJF24S41S1  
Y*(8,L)(C,V)*A12  
Y*(8,L)(C,V)*B12  
Y*(8,L)(C,V)*C16  
Y*(8,L)(C,V)*C20  
Y*9(C,V)*B12  
Y*9(C,V)*C16  
Y*9(C,V)*C20  
Y*(8,L)(C,V)*A12  
Y*(8,L)(C,V)*B12  
Y*(8,L)(C,V)*C16  
Y*(8,L)(C,V)*C20  
Y*9(C,V)*B12  
Y*9(C,V)*C16  
Y*9(C,V)*C20  
T*(8,L)X*A12  
T*(8,L)X*B12  
T*(8,L)X*C16  
T*9X*B12  
T*9X*C16  
Y*(8,L)(C,V)*A12  
Y*(8,L)(C,V)*B12  
Y*(8,L)(C,V)*C16  
Y*(8,L)(C,V)*C20  
Y*9(C,V)*B12  
Y*9(C,V)*C16  
Y*9(C,V)*C20  
YHJF30S41S1  
For Notes See Page 9.  
8
Johnson Controls Unitary Products  
510667-YTG-A-0409  
HEATING CAPACITY - With High Efficiency Motor Furnaces (Continued)  
ARI HEATING2  
COIL1  
MODEL  
FURNACE  
MODEL  
MODEL  
47F  
17F  
COP  
2.54  
2.54  
2.56  
2.60  
2.54  
2.56  
2.52  
2.50  
2.52  
2.52  
2.50  
2.78  
2.78  
2.72  
2.74  
2.76  
2.70  
2.74  
2.64  
2.68  
2.70  
2.56  
2.58  
2.56  
2.58  
2.56  
2.56  
2.54  
2.50  
2.52  
HSPF  
MBH  
36.0  
36.0  
36.0  
36.0  
36.0  
36.0  
36.0  
36.0  
36.0  
36.0  
36.0  
40.5  
41.0  
41.0  
40.5  
40.5  
41.0  
41.0  
41.5  
41.0  
41.0  
48.0  
48.0  
48.0  
48.0  
48.0  
48.0  
48.0  
48.0  
48.0  
COP  
3.80  
3.80  
3.78  
3.88  
3.80  
3.82  
3.74  
3.72  
3.74  
3.76  
3.70  
4.06  
4.08  
3.98  
4.02  
4.02  
3.96  
4.00  
3.86  
3.90  
3.94  
3.78  
3.80  
3.76  
3.80  
3.76  
3.76  
3.72  
3.68  
3.72  
KW  
2.78  
2.78  
2.79  
2.72  
2.78  
2.76  
2.82  
2.84  
2.82  
2.81  
2.85  
2.92  
2.94  
3.02  
2.95  
2.95  
3.03  
3.00  
3.15  
3.08  
3.05  
3.72  
3.70  
3.74  
3.70  
3.74  
3.74  
3.78  
3.82  
3.78  
MBH  
24.6  
24.6  
24.0  
24.4  
24.6  
24.4  
24.2  
24.4  
24.2  
24.6  
24.4  
26.0  
26.2  
26.2  
26.2  
26.0  
26.4  
26.2  
26.6  
26.4  
26.4  
32.0  
31.8  
32.0  
32.0  
32.0  
32.0  
32.2  
32.4  
32.2  
KW  
2.84  
2.84  
2.75  
2.75  
2.84  
2.79  
2.81  
2.86  
2.81  
2.86  
2.86  
2.74  
2.76  
2.82  
2.80  
2.76  
2.86  
2.80  
2.95  
2.89  
2.86  
3.66  
3.61  
3.66  
3.63  
3.66  
3.66  
3.71  
3.80  
3.74  
STD  
8.50  
8.50  
9.00  
9.00  
8.50  
8.50  
8.50  
8.50  
8.50  
8.50  
8.50  
9.00  
9.00  
9.00  
9.00  
9.00  
9.00  
9.00  
9.00  
9.00  
9.00  
9.00  
9.00  
9.00  
9.00  
9.00  
9.00  
9.00  
9.00  
9.00  
T*(8,L)X*A12  
T*(8,L)X*B12  
T*(8,L)X*C16  
T*(8,L)X*C20  
T*9X*B12  
FC/MC/PC37A  
FC/MC/PC43B  
FC/MC/PC43C  
FC/MC/PC43C  
FC/MC/PC43B  
FC/MC/PC43C  
FC/MC/PC43C  
FC/MC/PC43C  
FC/MC/PC43C  
FC/MC/PC43C  
FC/MC/PC43C  
FC/MC62D  
YHJF36S41S1  
T*9X*C16  
T*9X*C20  
Y*(8,L)(C,V)*C16  
Y*(8,L)(C,V)*C20  
Y*9(C,V)*C16  
Y*9(C,V)*C20  
T*(8,L)X*C16  
T*(8,L)X*C20  
T*9X*C16  
FC/MC62D  
FC/MC62D  
T*9X*C20  
FC/MC62D  
T*9X*D20  
FC/MC62D  
YHJF42S41S1  
Y*(8,L)(C,V)*C16  
Y*(8,L)(C,V)*C20  
Y*9(C,V)*C16  
Y*9(C,V)*C20  
Y*9(C,V)*D20  
T*(8,L)X*C16  
T*(8,L)X*C20  
T*9X*C16  
FC/MC62D  
FC/MC62D  
FC/MC62D  
FC/MC62D  
FC/MC62D  
FC/MC62D  
FC/MC62D  
FC/MC62D  
T*9X*C20  
FC/MC62D  
YHJF48S41S1  
T*9X*D20  
FC/MC62D  
Y*(8,L)(C,V)*C20  
Y*9(C,V)*C16  
Y*9(C,V)*C20  
Y*9(C,V)*D20  
FC/MC62D  
FC/MC62D  
FC/MC62D  
FC/MC62D  
1. MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.  
2. Heating MBH based on ARI standards of 70° DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and no  
supplemental electric heat operation.  
3. Variable speed furnaces have B.O.D (Blower on Delay) standard.  
CP equals MBH output divided by (total KW input x 3.412).  
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the  
total electric power input during the same period.  
— = Not Applicable.  
Johnson Controls Unitary Products  
9
510667-YTG-A-0409  
HEATING CAPACITY - With High Efficiency Motor Furnaces  
HEATING2  
NET MBH  
COIL  
MODEL1  
UNIT  
MODEL  
VARIABLE SPEED  
FURNACE MODEL  
RATED  
CFM  
STAGE  
HSPF  
COP @ 47  
47 OD  
17 OD  
14.5 SEER HP WITH VARIABLE SPEED FURNACES3  
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
835  
42.0  
57.0  
56.5  
43.5  
57.0  
55.6  
43.5  
57.0  
55.6  
42.5  
57.0  
55.6  
43.0  
57.0  
54.9  
43.0  
57.0  
55.6  
2.98  
3.64  
2.62  
3.38  
3.58  
3.08  
3.42  
3.60  
3.10  
3.20  
3.58  
2.86  
3.20  
3.54  
2.88  
3.26  
3.54  
2.94  
T*(8,L)X*C20  
T*9X*C20  
FC/MC62D  
FC/MC62D  
FC/MC62D  
FC/MC62D  
FC/MC62D  
FC/MC62D  
1665  
835  
39.5  
38.5  
9.00  
8.85  
1220  
1595  
1220  
1240  
1645  
1240  
1015  
1615  
1015  
1040  
1655  
1040  
1085  
1630  
1085  
40.0  
39.0  
9.00  
8.60  
T*9X*D20  
40.0  
39.0  
9.00  
8.65  
YHJF60S41S1  
Y*(8,L)(C,V)*C20  
Y*9(C,V)*C20  
Y*9(C,V)*D20  
40.0  
39.0  
9.00  
8.75  
40.5  
39.0  
9.00  
8.70  
40.0  
39.0  
9.00  
8.65  
1. MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.  
2. Heating MBH based on ARI standards of 70° DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and no  
supplemental electric heat operation.  
3. Variable speed furnaces have B.O.D (Blower on Delay) standard.  
CP equals MBH output divided by (total KW input x 3.412).  
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the  
total electric power input during the same period.  
— = Not Applicable.  
pump operation below -1°F ambient temperature.  
ACCESSORIES  
Thermal Expansion Valve Kit - 1TVM4 Series TXV kit used  
Refer to Price Manual for specific model numbers.  
when required.  
Start Assist Kit - Provides starting torque for low voltage appli-  
Outdoor Thermostat (2TD06700124) - Provides additional  
cations.  
staging of supplemental electric heat.  
Blower Time Delay - Available to increase efficiency when  
installed. Installs on indoor section and maintains blower for  
approximately one minute after cooling thermostat has been  
satisfied.  
Room Thermostats - A wide selection of matching thermostats  
is available to provide features required for any installation.  
* For the most current accessory information, refer to the price  
book or consult factory.  
Low Temperature Cutout (2LT06700224) - Prevents heat  
10  
Johnson Controls Unitary Products  
510667-YTG-A-0409  
SOUND LEVEL - TYPICAL OCTAVE BAND SPECTRUM (without tone adjustment)  
Test Condition  
63  
125  
85.4  
69.2  
69.0  
73.6  
71.0  
68.8  
70.1  
69.3  
70.1  
69.5  
72.6  
71.0  
72.5  
69.4  
72.7  
250  
85.9  
64.6  
64.0  
64.0  
68.5  
64.3  
67.5  
65.3  
66.9  
72.1  
68.1  
68.4  
74.0  
71.4  
69.6  
500  
85.3  
67.3  
66.4  
70.0  
74.1  
65.3  
66.7  
66.4  
68.5  
69.0  
70.5  
68.1  
73.6  
73.2  
71.3  
1000  
88.1  
65.5  
66.6  
71.8  
71.9  
65.5  
69.4  
66.3  
68.4  
71.3  
70.9  
67.9  
75.8  
71.2  
72.4  
2000  
88.6  
61.5  
59.6  
63.2  
63.4  
60.3  
62.5  
59.7  
61.6  
60.6  
62.7  
60.1  
64.0  
61.1  
63.4  
4000  
86.6  
58.2  
56.4  
57.3  
59.8  
55.8  
58.3  
56.7  
59.4  
56.9  
59.2  
55.8  
63.2  
57.6  
61.5  
8000  
83.9  
51.8  
52.6  
52.3  
53.4  
50.6  
52.7  
50.8  
55.5  
54.0  
56.9  
51.3  
56.8  
52.8  
57.4  
dBA  
SQI  
Size  
18  
24  
30  
36  
42  
48  
60  
RSS Sound Power Calibration 1091 402  
Cooling Mode  
82.8  
67.3  
68.9  
70.0  
72.2  
70.5  
72.2  
70.9  
73.2  
71.7  
72.6  
71.0  
73.6  
71.2  
71.6  
70.0  
69.7  
73.9  
75.4  
69.0  
72.0  
69.6  
71.7  
73.3  
73.6  
70.8  
77.6  
74.7  
75.0  
19.21  
19.17  
19.19  
19.14  
19.01  
19.03  
19.14  
19.12  
19.01  
19.02  
19.11  
19.08  
19.09  
19.05  
Heating Mode  
Cooling Mode  
Heating Mode  
Cooling Mode  
Heating Mode  
Cooling Mode  
Heating Mode  
Cooling Mode  
Heating Mode  
Cooling Mode  
Heating Mode  
Cooling Mode - High Stage  
Heating Mode - High Stage  
* Rated in accordance with ARI 270-2008 Standards.  
TYPICAL INSTALLATION  
MINIMUM 24” SERVICE  
ACCESS CLEARANCE  
ON ONE SIDE  
THERMOSTAT  
48” OVERHEAD  
CLEARANCE  
WEATHERPROOF  
DISCONNECT  
SWITCH  
NEC CLASS 1 WIRING  
10” CLEARANCE  
AROUND PERIMETER  
TO FURNACE OR  
AIR HANDLER  
TERMINAL BLOCK  
NEC CLASS 2 WIRING  
TO INDOOR COIL  
NOTE:  
ALL OUTDOOR WIRING  
MUST BE WEATHERPROOF.  
CONTROL  
ACCESS  
PANEL  
SEAL OPENING(S) WITH  
PERMAGUM OR EQUIVALENT  
TYPICAL FIELD WIRING  
ALL FIELD WIRING TO BE IN ACCORDANCE WITH ELECTRIC CODE (NEC) AND/OR LOCAL CODES  
THERMOSTAT  
INDOOR UNIT  
OUTDOOR UNIT  
3,4  
DEFROST  
CONTROL  
LOW VOLTAGE TERMINAL BLOCK  
IN AIR HANDLER WITH ELECTRIC HEAT  
RED  
R
C
R
B or C  
Y
R
C
CONTACTOR  
BLK  
T2  
L2  
YEL  
T1  
L1  
Y
Y
ORG  
M
O
O
O
GND.  
SCREW  
BRN  
PUR  
W2  
W
W
X/L  
L or X  
WHT  
5GRY  
G
G
/66  
W1  
1
T2  
E2  
FIELD  
INSTALLED  
JUMPER  
W1  
BK  
CC  
DEHUMIDIFICATION CONTROL CONNECTION  
(Humidistat* Jumper must be removed)  
1
2
JUMPER TERMINALS E AND W TO HEAT  
ON FIRST STAGE DURING EMERGENCY HEAT.  
GND.  
LUG  
POWER WIRING  
208/230-1-60  
230-1-50  
TERMINAL NOT USED ON ALL THERMOSTATS.  
CIRCUIT  
POWER WIRING  
BREAKER***  
24V CONTROL WIRING  
(NEC CLASS 2)  
3
CHECK THE LOW VOLTAGE TERMINAL BLOCK ON THE INDOOR UNIT FOR THE ACTUAL ARRANGEMENT OF THE TERMINALS.  
CONNECT POWER WIRING TO TERMINAL BLOCK 3TB ON UNITS WITHOUT ELECTRIC HEAT OR CIRCUIT BREAKER.  
GRAY FOR USE WITH OPTIONAL OUTDOOR THERMOSTAT KITS.  
4
5
Johnson Controls Unitary Products  
11  
510667-YTG-A-0409  
COOLING PERFORMANCE DATA  
CONDENSING UNIT MODEL NO. YHJF18S41S1  
INDOOR COIL MODEL NO.  
AHX30  
IDCFM  
400  
75  
600  
75  
800  
75  
CONDENSING  
ENTERING AIR  
TEMPERATURE  
ID DB (°F)  
ID WB (°F)  
T.C.  
80  
57  
80  
62  
80  
67  
80  
72  
80  
57  
80  
62  
80  
67  
80  
72  
80  
57  
80  
62  
80  
67  
80  
72  
62  
62  
62  
17.2 18.8 18.8 20.5 22.2 19.2 19.9 20.1 21.7 22.9 21.2 20.9 21.3 22.8 23.6  
16.8 14.9 12.9 12.9 11.0 18.8 17.7 15.2 14.7 11.7 20.8 20.5 17.4 16.5 12.5  
65  
75  
S.C.  
KW  
0.9  
0.9  
0.9  
0.9  
0.9  
0.9  
1.0  
1.0  
1.0  
1.0  
1.0  
1.0  
1.0  
1.0  
1.0  
T.C.  
16.4 17.9 17.9 19.7 21.3 18.4 19.1 19.0 20.8 22.1 20.4 20.2 20.2 21.8 22.9  
16.1 14.5 12.5 12.5 10.5 18.0 17.1 14.8 14.4 11.5 20.0 19.8 17.0 16.3 12.4  
S.C.  
KW  
1.0  
1.0  
1.0  
1.0  
1.0  
1.1  
1.1  
1.1  
1.1  
1.1  
1.2  
1.2  
1.2  
1.2  
1.2  
T.C.  
15.7 17.0 17.0 18.9 20.4 17.7 18.3 18.0 19.9 21.3 19.6 19.5 19.1 20.8 22.1  
15.4 14.1 12.1 12.1 10.1 17.3 16.6 14.3 14.2 11.2 19.2 19.1 16.6 16.2 12.2  
85  
S.C.  
KW  
1.1  
15.0 16.1 16.1 18.1 19.6 16.9 17.4 17.0 19.0 20.4 18.8 18.8 18.0 19.8 21.3  
14.7 13.7 11.6 11.8 9.7 16.5 16.0 13.9 13.9 10.9 18.4 18.4 16.2 16.0 12.1  
1.3 1.3 1.3 1.3 1.3 1.4 1.4 1.4 1.4 1.4 1.5 1.5 1.5 1.5 1.5  
14.0 14.7 14.8 16.7 18.4 15.9 16.2 15.7 17.6 19.2 17.7 17.7 16.6 18.5 20.1  
13.7 13.1 11.0 11.2 9.2 15.5 15.2 13.3 13.4 10.4 17.3 17.3 15.6 15.6 11.6  
1.4 1.4 1.4 1.5 1.5 1.5 1.5 1.5 1.5 1.6 1.6 1.6 1.6 1.6 1.7  
1.1  
1.1  
1.2  
1.2  
1.2  
1.2  
1.2  
1.2  
1.3  
1.3  
1.3  
1.3  
1.3  
1.3  
T.C.  
95  
S.C.  
KW  
T.C.  
105  
115  
125  
S.C.  
KW  
T.C.  
13.1 13.4 13.4 15.4 17.2 14.8 15.0 14.4 16.2 18.0 16.6 16.6 15.3 17.1 18.8  
12.8 12.5 10.5 10.6 8.7 14.5 14.4 12.7 12.9 9.9 16.2 16.2 15.0 15.1 11.2  
S.C.  
KW  
1.6  
12.2 12.1 12.1 14.0 16.1 13.8 13.8 13.0 14.9 16.8 15.5 15.5 14.0 15.7 17.5  
11.9 11.9 9.9 10.1 8.2 13.5 13.5 12.1 12.3 9.5 15.1 15.1 14.0 14.6 10.7  
1.7 1.7 1.7 1.8 1.8 1.8 1.8 1.8 1.9 1.9 2.0 2.0 1.9 2.0 2.0  
1.6  
1.6  
1.6  
1.7  
1.7  
1.7  
1.7  
1.7  
1.7  
1.8  
1.8  
1.8  
1.8  
1.8  
T.C.  
S.C.  
KW  
NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.  
Multipliers for determining the performance with other indoor sections.  
NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed  
temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.  
Air Handler  
AV*36  
Coil  
T.C.  
1.00  
1.00  
1.00  
S.C.  
1.00  
0.98  
1.00  
KW  
1.08  
1.08  
1.08  
Variable Speed  
Furnace  
Coil  
T.C.  
S.C.  
KW  
T*(8,L)X*A12  
FC/MC/PC32A  
FC/MC/PC32A  
FC/MC/PC35B  
FC/MC/PC35C  
FC/MC/PC35B  
FC/MC/PC35C  
FC/MC/PC37A  
FC/MC/PC43B  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
0.98  
0.98  
1.01  
0.98  
0.98  
1.01  
1.00  
0.96  
1.08  
1.08  
1.08  
1.08  
1.08  
1.08  
1.08  
1.08  
MV12B  
FC/MC35B  
FC/MC43B  
Y*(8,L)(C,V)*A12  
Y*(8,L)(C,V)*B12  
Y*(8,L)(C,V)*C16  
Y*9(C,V)*B12  
MV12B  
Y*9(C,V)*C16  
Y*(8,L)(C,V)*A12  
Y*(8,L)(C,V)*B12  
12  
Johnson Controls Unitary Products  
510667-YTG-A-0409  
COOLING PERFORMANCE DATA  
CONDENSING UNIT MODEL NO. YHJF24S41S1  
INDOOR COIL MODEL NO.  
AHX30  
IDCFM  
600  
75  
800  
75  
1000  
CONDENSING  
ENTERING AIR  
TEMPERATURE  
ID DB (°F)  
ID WB (°F)  
T.C.  
80  
57  
80  
62  
80  
67  
80  
72  
80  
57  
80  
62  
80  
67  
80  
72  
80  
57  
80  
62  
75  
62  
80  
67  
80  
72  
62  
62  
21.7 23.6 23.5 25.2 26.6 23.4 24.1 24.3 26.0 27.2 25.1 24.6 25.1 26.9 27.8  
21.4 19.4 16.6 16.2 13.7 23.1 21.8 18.5 17.9 14.3 24.8 24.3 20.5 19.5 15.0  
65  
75  
S.C.  
KW  
1.2  
1.2  
1.2  
1.2  
1.2  
1.3  
1.3  
1.3  
1.3  
1.3  
1.4  
1.4  
1.4  
1.4  
1.4  
T.C.  
20.8 22.3 22.2 24.0 25.7 22.4 23.0 23.0 24.8 26.3 24.1 23.8 23.8 25.7 26.9  
20.5 18.8 16.0 15.7 13.1 22.1 21.1 18.0 17.5 13.9 23.8 23.5 19.9 19.2 14.6  
S.C.  
KW  
1.4  
1.4  
1.4  
1.4  
1.4  
1.4  
1.4  
1.4  
1.5  
1.5  
1.5  
1.5  
1.5  
1.5  
1.5  
T.C.  
19.8 20.9 20.9 22.9 24.8 21.4 21.9 21.6 23.7 25.5 23.1 22.9 22.4 24.5 26.1  
19.5 18.2 15.4 15.3 12.5 21.2 20.4 17.4 17.1 13.4 22.8 22.6 19.4 18.9 14.3  
85  
S.C.  
KW  
1.5  
1.5  
1.5  
1.5  
1.6  
1.6  
1.6  
1.6  
1.6  
1.6  
1.7  
1.7  
1.7  
1.7  
1.7  
T.C.  
18.8 19.5 19.6 21.8 23.9 20.5 20.8 20.3 22.5 24.6 22.1 22.1 21.1 23.2 25.3  
18.6 17.5 14.8 14.8 11.9 20.2 19.7 16.8 16.7 12.9 21.8 21.8 18.8 18.7 14.0  
95  
S.C.  
KW  
1.7  
1.7  
1.7  
1.7  
1.7  
1.8  
1.8  
1.7  
1.8  
1.8  
1.9  
1.9  
1.8  
1.9  
1.9  
T.C.  
17.7 18.0 18.0 20.2 22.4 19.2 19.3 18.7 20.9 23.1 20.7 20.7 19.4 21.6 23.7  
17.4 16.8 14.1 14.2 11.3 18.9 18.7 16.1 16.1 12.4 20.5 20.5 18.2 18.1 13.5  
105  
115  
125  
S.C.  
KW  
1.9  
1.9  
1.9  
1.9  
2.0  
2.0  
2.0  
1.9  
2.0  
2.0  
2.1  
2.1  
2.0  
2.1  
2.1  
T.C.  
16.5 16.4 16.4 18.7 20.9 17.9 17.9 17.0 19.3 21.6 19.4 19.4 17.7 20.0 22.2  
16.3 16.1 13.4 13.5 10.8 17.7 17.6 15.4 15.5 11.9 19.2 19.2 17.5 17.5 13.0  
S.C.  
KW  
2.1  
2.1  
2.1  
2.1  
2.2  
2.2  
2.2  
2.1  
2.2  
2.2  
2.3  
2.3  
2.2  
2.3  
2.3  
T.C.  
15.3 14.8 14.8 17.1 19.4 16.7 16.4 15.4 17.7 20.0 18.1 18.1 16.1 18.3 20.6  
15.1 14.8 12.7 12.9 10.2 16.5 16.4 14.7 14.9 11.3 17.8 17.8 16.1 16.9 12.5  
S.C.  
KW  
2.2  
2.2  
2.2  
2.3  
2.4  
2.4  
2.4  
2.4  
2.4  
2.4  
2.5  
2.5  
2.5  
2.5  
2.5  
NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.  
Multipliers for determining the performance with other indoor sections.  
NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed  
temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.  
Variable Speed  
Furnace  
Air Handler  
AHX36  
Coil  
T.C.  
1.01  
1.00  
1.00  
1.00  
1.00  
1.03  
S.C.  
1.02  
0.98  
1.01  
1.02  
1.01  
1.05  
KW  
1.03  
1.02  
1.07  
1.02  
1.02  
1.05  
Coil  
T.C.  
S.C.  
KW  
T*(8,L)X*C16  
T*9X*B12  
FC/MC/PC43C  
FC/MC/PC43B  
FC/MC/PC43C  
FC/MC/PC43C  
FC/MC/PC32A  
FC/MC/PC35B  
FC/MC/PC35C  
FC/MC/PC35C  
FC/MC/PC35B  
FC/MC/PC35C  
FC/MC/PC35C  
FC/MC/PC37A  
FC/MC/PC43B  
FC/MC/PC43C  
FC/MC/PC43C  
FC/MC/PC43B  
FC/MC/PC43C  
FC/MC/PC43C  
1.03  
1.03  
1.02  
1.02  
1.00  
0.99  
1.01  
0.99  
1.00  
1.02  
0.99  
1.02  
1.00  
1.03  
1.01  
1.02  
1.03  
1.03  
1.06  
1.05  
1.02  
1.02  
1.00  
0.98  
1.04  
0.97  
1.00  
1.06  
0.98  
1.05  
0.99  
1.08  
1.00  
1.05  
1.05  
1.08  
1.05  
1.05  
1.04  
1.04  
1.07  
1.02  
1.03  
1.02  
1.07  
1.04  
1.02  
1.04  
1.02  
1.05  
1.03  
1.04  
1.05  
1.05  
AV*36  
F6FP030  
F6FP036  
MV12B  
T*9X*C16  
T*9X*C20  
FC/MC35B  
FC/MC43B  
Y*(8,L)(C,V)*A12  
Y*(8,L)(C,V)*B12  
Y*(8,L)(C,V)*C16  
Y*(8,L)(C,V)*C20  
Y*9(C,V)*B12  
Y*9(C,V)*C16  
Y*9(C,V)*C20  
Y*(8,L)(C,V)*A12  
Y*(8,L)(C,V)*B12  
Y*(8,L)(C,V)*C16  
Y*(8,L)(C,V)*C20  
Y*9(C,V)*B12  
Y*9(C,V)*C16  
Y*9(C,V)*C20  
MV12B  
Variable Speed  
Furnace  
Coil  
T.C.  
S.C.  
KW  
T*(8,L)X*A12  
T*(8,L)X*B12  
T*(8,L)X*C16  
T*(8,L)X*C20  
T*9X*B12  
FC/MC/PC32A  
FC/MC/PC35B  
FC/MC/PC35C  
FC/MC/PC35C  
FC/MC/PC35B  
FC/MC/PC35C  
FC/MC/PC35C  
FC/MC/PC37A  
FC/MC/PC43B  
1.01  
1.01  
1.02  
1.02  
1.01  
1.01  
1.01  
1.03  
1.03  
1.01  
1.04  
1.05  
1.06  
1.01  
1.01  
1.01  
1.05  
1.06  
1.03  
1.03  
1.04  
1.04  
1.03  
1.03  
1.03  
1.05  
1.05  
T*9X*C16  
T*9X*C20  
T*(8,L)X*A12  
T*(8,L)X*B12  
Johnson Controls Unitary Products  
13  
510667-YTG-A-0409  
COOLING PERFORMANCE DATA  
CONDENSING UNIT MODEL NO. YHJF30S41S1  
INDOOR COIL MODEL NO.  
AHX36  
IDCFM  
800  
75  
1000  
75  
1200  
75  
CONDENSING  
ENTERING AIR  
TEMPERATURE  
ID DB (°F)  
ID WB (°F)  
T.C.  
80  
57  
80  
62  
80  
67  
80  
72  
80  
57  
80  
62  
80  
67  
80  
72  
80  
57  
80  
62  
80  
67  
80  
72  
62  
62  
62  
28.4 30.2 30.1 33.0 34.3 30.2 31.2 31.2 33.5 34.8 32.0 32.2 32.2 34.0 35.3  
28.4 26.3 22.5 22.3 18.2 30.2 29.6 24.6 23.7 18.7 32.0 32.2 26.8 25.1 19.1  
65  
75  
S.C.  
KW  
1.5  
1.5  
1.5  
1.6  
1.5  
1.6  
1.6  
1.6  
1.6  
1.6  
1.7  
1.7  
1.7  
1.7  
1.7  
T.C.  
27.3 28.7 28.7 31.5 33.2 29.0 29.7 29.6 32.1 33.7 30.7 30.6 30.6 32.7 34.2  
27.3 25.7 21.8 21.6 17.7 29.0 28.4 23.9 23.2 18.2 30.7 30.6 26.1 24.8 18.7  
S.C.  
KW  
1.7  
1.7  
1.7  
1.7  
1.7  
1.8  
1.8  
1.8  
1.8  
1.8  
1.9  
1.9  
1.9  
1.8  
1.8  
T.C.  
26.2 27.2 27.2 30.0 32.2 27.8 28.1 28.1 30.7 32.6 29.5 29.0 29.0 31.4 33.1  
26.2 25.0 21.1 21.0 17.1 27.8 27.3 23.3 22.8 17.7 29.5 29.0 25.4 24.6 18.4  
85  
S.C.  
KW  
1.8  
1.9  
1.9  
1.9  
1.9  
1.9  
1.9  
1.9  
2.0  
2.0  
2.0  
2.0  
2.0  
2.0  
2.0  
T.C.  
25.1 25.8 25.8 28.6 31.1 26.7 26.6 26.6 29.3 31.5 28.2 27.3 27.3 30.1 32.0  
25.1 24.4 20.4 20.4 16.5 26.7 26.1 22.6 22.4 17.3 28.2 27.3 24.7 24.4 18.1  
95  
S.C.  
KW  
2.0  
2.0  
2.0  
2.0  
2.1  
2.1  
2.1  
2.1  
2.1  
2.1  
2.2  
2.1  
2.1  
2.2  
2.2  
T.C.  
23.7 23.8 23.9 26.9 29.5 25.2 25.1 24.6 27.6 29.9 26.7 26.3 25.4 28.2 30.3  
23.7 23.4 19.6 19.7 15.7 25.2 25.1 21.7 21.7 16.6 26.7 26.3 23.9 23.7 17.5  
105  
115  
125  
S.C.  
KW  
2.2  
2.2  
2.2  
2.3  
2.3  
2.3  
2.3  
2.3  
2.4  
2.4  
2.4  
2.4  
2.4  
2.4  
2.4  
T.C.  
22.2 21.9 21.9 25.2 27.8 23.7 23.6 22.7 25.8 28.3 25.2 25.2 23.4 26.4 28.7  
22.2 21.9 18.7 19.0 15.0 23.7 23.6 20.9 21.0 16.0 25.2 25.2 23.1 23.0 17.0  
S.C.  
KW  
2.4  
2.4  
2.4  
2.5  
2.5  
2.5  
2.5  
2.5  
2.6  
2.6  
2.6  
2.6  
2.6  
2.7  
2.7  
T.C.  
20.8 19.9 20.0 23.5 26.2 22.2 22.1 20.7 24.0 26.7 23.7 24.2 21.5 24.5 27.1  
20.8 19.9 17.8 18.3 14.2 22.2 22.1 20.1 20.3 15.3 23.7 24.2 21.5 22.3 16.4  
S.C.  
KW  
2.6  
2.6  
2.6  
2.7  
2.8  
2.7  
2.8  
2.7  
2.8  
2.8  
2.8  
2.9  
2.9  
2.9  
2.9  
NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.  
Multipliers for determining the performance with other indoor sections.  
NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed  
temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.  
Air Handler  
AV*36  
Coil  
T.C.  
0.99  
0.99  
0.99  
0.99  
S.C.  
0.98  
0.98  
0.97  
0.97  
KW  
1.09  
1.09  
1.09  
1.09  
Variable Speed  
Furnace  
Coil  
T.C.  
S.C.  
KW  
T*(8,L)X*A12  
T*(8,L)X*B12  
T*(8,L)X*C16  
T*9X*B12  
FC/MC/PC37A  
FC/MC/PC43B  
FC/MC/PC43C  
FC/MC/PC43B  
FC/MC/PC43C  
FC/MC/PC37A  
FC/MC/PC43B  
FC/MC/PC43C  
FC/MC/PC43C  
FC/MC/PC43B  
FC/MC/PC43C  
FC/MC/PC43C  
1.00  
1.01  
0.99  
1.00  
1.00  
0.97  
0.98  
0.99  
0.99  
0.99  
0.99  
0.99  
1.04  
1.05  
0.97  
1.04  
1.02  
0.96  
0.96  
0.97  
0.97  
0.99  
1.00  
0.97  
1.10  
1.11  
1.09  
1.10  
1.10  
1.11  
1.08  
1.09  
1.09  
1.13  
1.09  
1.09  
F6FP42  
MV12B  
FC/MC43B  
FC/MC43C  
MV16C  
T*9X*C16  
Y*(8,L)(C,V)*A12  
Y*(8,L)(C,V)*B12  
Y*(8,L)(C,V)*C16  
Y*(8,L)(C,V)*C20  
Y*9(C,V)*B12  
Y*9(C,V)*C16  
Y*9(C,V)*C20  
14  
Johnson Controls Unitary Products  
510667-YTG-A-0409  
COOLING PERFORMANCE DATA  
CONDENSING UNIT MODEL NO. YHJF36S41S1  
INDOOR COIL MODEL NO.  
AHX36  
IDCFM  
1000  
75  
1200  
75  
1400  
CONDENSING  
ENTERING AIR  
TEMPERATURE  
ID DB (°F)  
ID WB (°F)  
T.C.  
80  
57  
80  
62  
80  
67  
80  
72  
80  
57  
80  
62  
80  
67  
80  
72  
80  
57  
80  
62  
75  
62  
80  
67  
80  
72  
62  
62  
34.5 36.4 37.1 40.1 42.7 36.2 37.6 37.8 41.2 43.4 38.0 38.7 38.5 42.3 44.1  
34.5 36.4 32.5 32.1 26.5 36.2 37.6 34.8 34.5 27.5 38.0 38.7 37.1 36.9 28.4  
65  
75  
S.C.  
KW  
1.9  
2.0  
2.0  
2.0  
2.0  
2.0  
2.1  
2.1  
2.1  
2.1  
2.1  
2.1  
2.1  
2.2  
2.2  
T.C.  
33.0 34.5 34.9 38.1 41.1 34.7 35.6 35.7 39.2 41.7 36.4 36.6 36.5 40.2 42.4  
33.0 34.5 31.4 31.1 25.5 34.7 35.6 33.8 33.5 26.5 36.4 36.6 36.1 35.9 27.5  
S.C.  
KW  
2.2  
2.2  
2.2  
2.3  
2.3  
2.3  
2.3  
2.3  
2.3  
2.4  
2.4  
2.4  
2.4  
2.4  
2.4  
T.C.  
31.5 32.6 32.8 36.2 39.4 33.2 33.6 33.6 37.1 40.0 34.9 34.5 34.4 38.1 40.6  
31.5 32.6 30.2 30.1 24.5 33.2 33.6 32.7 32.5 25.6 34.9 34.5 34.4 34.9 26.7  
85  
S.C.  
KW  
2.4  
2.5  
2.5  
2.5  
2.6  
2.5  
2.6  
2.6  
2.6  
2.6  
2.6  
2.6  
2.6  
2.7  
2.7  
T.C.  
29.9 30.7 30.6 34.3 37.8 31.6 31.6 31.5 35.1 38.3 33.3 32.4 32.4 36.0 38.9  
29.9 30.7 29.1 29.2 23.4 31.6 31.6 31.5 31.5 24.6 33.3 32.4 32.4 33.9 25.8  
95  
S.C.  
KW  
2.7  
2.7  
2.7  
2.8  
2.8  
2.8  
2.8  
2.8  
2.9  
2.9  
2.9  
2.9  
2.9  
2.9  
2.9  
T.C.  
28.2 28.1 28.0 31.8 35.3 29.8 29.4 28.9 32.6 35.9 31.4 30.8 29.7 33.4 36.6  
28.2 28.1 27.6 28.0 22.3 29.8 29.4 28.9 30.3 23.6 31.4 30.8 29.7 32.7 24.8  
105  
115  
125  
S.C.  
KW  
3.0  
3.0  
3.0  
3.0  
3.1  
3.1  
3.1  
3.1  
3.1  
3.2  
3.2  
3.2  
3.2  
3.2  
3.2  
T.C.  
26.5 25.5 25.3 29.4 32.7 28.0 27.3 26.2 30.1 33.5 29.5 29.2 27.1 30.9 34.2  
26.5 25.5 25.3 26.8 21.2 28.0 27.3 26.2 29.2 22.5 29.5 29.2 27.1 30.9 23.8  
S.C.  
KW  
3.3  
3.3  
3.3  
3.3  
3.3  
3.4  
3.4  
3.4  
3.4  
3.4  
3.5  
3.5  
3.4  
3.5  
3.5  
T.C.  
24.7 22.9 22.6 27.0 30.2 26.2 25.2 23.6 27.7 31.0 27.6 27.6 24.5 28.3 31.9  
24.7 22.9 22.6 25.6 20.1 26.2 25.2 23.6 27.7 21.4 27.6 27.6 24.5 28.3 22.7  
S.C.  
KW  
3.5  
3.5  
3.5  
3.6  
3.6  
3.6  
3.6  
3.6  
3.7  
3.7  
3.8  
3.7  
3.7  
3.7  
3.8  
NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.  
Multipliers for determining the performance with other indoor sections.  
NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed  
temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.  
Air Handler  
AHX42  
Coil  
T.C.  
1.01  
1.00  
1.02  
1.00  
0.99  
S.C.  
1.01  
0.99  
1.04  
1.00  
0.99  
KW  
1.03  
1.06  
1.03  
1.06  
1.05  
Variable Speed  
Furnace  
Coil  
T.C.  
S.C.  
KW  
T*(8,L)X*A12  
T*(8,L)X*B12  
T*(8,L)X*C16  
T*(8,L)X*C20  
T*9X*B12  
FC/MC/PC37A  
FC/MC/PC43B  
FC/MC/PC43C  
FC/MC/PC43C  
FC/MC/PC43B  
FC/MC/PC43C  
FC/MC/PC43C  
FC/MC/PC43C  
FC/MC/PC43C  
FC/MC/PC43C  
FC/MC/PC43C  
1.01  
1.01  
1.00  
1.02  
1.01  
1.02  
0.99  
0.99  
0.99  
1.01  
0.99  
1.03  
1.03  
0.99  
1.03  
1.03  
1.03  
0.99  
0.99  
0.99  
1.02  
0.99  
1.07  
1.07  
1.02  
1.03  
1.07  
1.08  
1.05  
1.02  
1.05  
1.06  
1.05  
AV*36  
F6FP042  
MV12B  
FC/MC43B  
FC/MC43C  
MV16C  
T*9X*C16  
T*9X*C20  
Y*(8,L)(C,V)*C16  
Y*(8,L)(C,V)*C20  
Y*9(C,V)*C16  
Y*9(C,V)*C20  
Johnson Controls Unitary Products  
15  
510667-YTG-A-0409  
COOLING PERFORMANCE DATA  
CONDENSING UNIT MODEL NO. YHJF42S41S1  
INDOOR COIL MODEL NO.  
AHX60  
IDCFM  
1155  
75  
1355  
75  
1555  
75  
CONDENSING  
ENTERING AIR  
TEMPERATURE  
ID DB (°F)  
ID WB (°F)  
T.C.  
80  
57  
80  
62  
80  
67  
80  
72  
80  
57  
80  
62  
80  
67  
80  
72  
80  
57  
80  
62  
80  
67  
80  
72  
62  
62  
62  
38.5 40.6 41.2 44.8 48.2 40.3 41.9 41.0 45.8 49.3 42.2 43.3 40.7 46.7 50.4  
38.5 35.5 30.5 30.2 24.7 40.3 39.2 32.0 32.1 25.8 42.2 42.9 33.6 33.9 26.8  
65  
75  
S.C.  
KW  
2.2  
2.2  
2.2  
2.2  
2.4  
2.3  
2.3  
2.3  
2.3  
2.4  
2.3  
2.3  
2.3  
2.5  
2.5  
T.C.  
36.9 38.6 39.0 42.8 46.3 38.7 39.7 39.1 43.7 47.3 40.6 40.8 39.2 44.6 48.3  
36.9 34.8 29.6 29.4 23.8 38.7 37.7 31.3 31.3 24.9 40.6 40.6 33.0 33.2 26.0  
S.C.  
KW  
2.5  
2.5  
2.5  
2.5  
2.6  
2.6  
2.6  
2.6  
2.6  
2.7  
2.6  
2.7  
2.6  
2.7  
2.8  
T.C.  
35.3 36.7 36.9 40.8 44.3 37.2 37.5 37.2 41.6 45.3 39.0 38.3 37.6 42.4 46.2  
35.3 34.0 28.6 28.6 23.0 37.2 36.2 30.5 30.5 24.1 39.0 38.3 32.5 32.4 25.1  
85  
S.C.  
KW  
2.8  
2.8  
2.8  
2.8  
2.9  
2.9  
2.9  
2.9  
2.9  
3.0  
3.0  
3.0  
2.9  
3.0  
3.1  
T.C.  
33.7 34.8 34.7 38.8 42.3 35.6 35.3 35.4 39.6 43.2 37.4 35.8 36.1 40.3 44.1  
33.7 33.3 27.7 27.7 22.2 35.6 34.7 29.8 29.7 23.2 37.4 35.8 31.9 31.6 24.3  
95  
S.C.  
KW  
3.0  
3.1  
3.1  
3.1  
3.1  
3.2  
3.2  
3.2  
3.2  
3.2  
3.3  
3.3  
3.2  
3.3  
3.4  
T.C.  
31.7 32.2 31.4 35.9 39.8 33.4 33.3 32.3 36.7 40.5 35.1 34.3 33.1 37.5 41.3  
31.7 31.6 26.3 26.6 21.1 33.4 33.1 28.5 28.6 22.2 35.1 34.3 30.7 30.6 23.3  
105  
115  
125  
S.C.  
KW  
3.3  
3.4  
3.4  
3.4  
3.5  
3.5  
3.5  
3.5  
3.5  
3.6  
3.6  
3.5  
3.5  
3.6  
3.7  
T.C.  
29.7 29.7 28.2 33.0 37.2 31.2 31.2 29.2 33.8 37.8 32.7 32.7 30.2 34.7 38.5  
29.7 29.7 24.9 25.4 20.1 31.2 31.2 27.2 27.5 21.2 32.7 32.7 29.5 29.6 22.3  
S.C.  
KW  
3.7  
3.7  
3.7  
3.7  
3.8  
3.8  
3.8  
3.8  
3.8  
3.9  
3.9  
3.8  
3.8  
3.9  
4.0  
T.C.  
27.6 27.1 25.0 30.1 34.6 29.0 29.2 26.1 31.0 35.1 30.4 31.2 27.2 31.9 35.6  
27.6 27.1 23.6 24.3 19.1 29.0 29.2 25.9 26.4 20.2 30.4 31.2 27.2 28.6 21.4  
S.C.  
KW  
4.0  
4.0  
4.0  
3.9  
4.1  
4.1  
4.1  
4.1  
4.1  
4.2  
4.2  
4.1  
4.1  
4.2  
4.3  
NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.  
Multipliers for determining the performance with other indoor sections.  
NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed  
temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.  
Air Handler  
F6FP060  
MV20D  
Coil  
T.C.  
1.01  
1.00  
S.C.  
1.04  
1.02  
KW  
1.04  
1.03  
Variable Speed  
Furnace  
Coil  
T.C.  
S.C.  
KW  
T*(8,L)X*C16  
T*(8,L)X*C20  
T*9X*C16  
FC/MC62D  
FC/MC62D  
FC/MC62D  
FC/MC62D  
FC/MC62D  
FC/MC62D  
FC/MC62D  
FC/MC62D  
FC/MC62D  
1.01  
1.01  
1.00  
1.01  
1.01  
1.01  
1.00  
1.00  
1.00  
1.03  
1.05  
1.02  
1.03  
1.03  
1.02  
1.01  
1.01  
1.01  
1.00  
1.00  
1.01  
1.04  
1.04  
1.04  
1.06  
1.04  
1.03  
FC/MC62D  
T*9X*C20  
T*9X*D20  
Y*(8,L)(C,V)*C20  
Y*9(C,V)*C16  
Y*9(C,V)*C20  
Y*9(C,V)*D20  
16  
Johnson Controls Unitary Products  
510667-YTG-A-0409  
COOLING PERFORMANCE DATA  
CONDENSING UNIT MODEL NO. YHJF48S41S1  
INDOOR COIL MODEL NO.  
F6FP060  
IDCFM  
1400  
75  
1600  
75  
1800  
CONDENSING  
ENTERING AIR  
TEMPERATURE  
ID DB (°F)  
ID WB (°F)  
T.C.  
80  
57  
80  
62  
80  
67  
80  
72  
80  
57  
80  
62  
80  
67  
80  
72  
80  
57  
80  
62  
75  
62  
80  
67  
80  
72  
62  
62  
46.3 48.5 48.5 53.1 57.3 48.0 50.1 49.9 53.5 58.0 49.8 51.6 51.4 53.9 58.7  
46.3 42.2 35.8 35.4 29.2 48.0 45.7 38.1 36.7 29.9 49.8 49.3 40.4 38.0 30.6  
65  
75  
S.C.  
KW  
2.7  
2.7  
2.7  
2.8  
2.7  
2.8  
2.8  
2.8  
2.8  
2.8  
2.9  
2.9  
2.9  
2.9  
2.9  
T.C.  
44.4 46.1 46.1 50.7 55.0 46.2 47.4 47.3 51.3 55.8 48.0 48.7 48.5 51.8 56.5  
44.4 41.2 34.8 34.4 28.2 46.2 44.2 37.0 36.0 29.0 48.0 47.1 39.2 37.5 29.8  
S.C.  
KW  
3.0  
3.0  
3.0  
3.0  
3.1  
3.1  
3.1  
3.1  
3.1  
3.2  
3.2  
3.2  
3.2  
3.2  
3.2  
T.C.  
42.4 43.6 43.6 48.3 52.7 44.3 44.7 44.7 49.0 53.5 46.2 45.7 45.7 49.8 54.3  
42.4 40.2 33.7 33.5 27.1 44.3 42.6 35.8 35.3 28.0 46.2 45.0 38.0 37.0 29.0  
85  
S.C.  
KW  
3.3  
3.3  
3.3  
3.3  
3.4  
3.4  
3.4  
3.4  
3.4  
3.5  
3.5  
3.5  
3.5  
3.6  
3.6  
T.C.  
40.5 41.1 41.2 45.9 50.5 42.5 42.0 42.0 46.8 51.3 44.4 42.8 42.8 47.7 52.1  
40.5 39.2 32.7 32.6 26.0 42.5 41.0 34.7 34.6 27.1 44.4 42.8 36.8 36.5 28.2  
95  
S.C.  
KW  
3.7  
3.7  
3.7  
3.6  
3.8  
3.8  
3.8  
3.8  
3.8  
3.9  
3.9  
3.9  
3.9  
3.9  
4.0  
T.C.  
37.9 38.3 37.6 42.7 47.5 39.7 39.5 38.5 43.5 48.2 41.5 40.7 39.3 44.3 48.8  
37.9 37.4 31.1 31.4 24.8 39.7 39.1 33.2 33.3 25.9 41.5 40.7 35.3 35.3 26.9  
105  
115  
125  
S.C.  
KW  
4.0  
4.0  
4.0  
4.1  
4.2  
4.2  
4.2  
4.1  
4.2  
4.3  
4.3  
4.3  
4.2  
4.3  
4.4  
T.C.  
35.2 35.5 34.0 39.5 44.6 36.9 37.1 34.9 40.2 45.1 38.7 38.7 35.8 41.0 45.5  
35.2 35.5 29.6 30.1 23.6 36.9 37.1 31.7 32.1 24.7 38.7 38.7 33.9 34.1 25.7  
S.C.  
KW  
4.4  
4.4  
4.4  
4.6  
4.6  
4.6  
4.6  
4.5  
4.7  
4.7  
4.7  
4.7  
4.6  
4.7  
4.8  
T.C.  
32.6 32.7 30.4 36.3 41.7 34.2 34.7 31.3 37.0 42.0 35.8 36.6 32.2 37.7 42.3  
32.6 32.7 28.0 28.8 22.4 34.2 34.7 30.2 30.9 23.5 35.8 36.6 32.2 32.9 24.5  
S.C.  
KW  
4.8  
4.8  
4.8  
5.0  
5.1  
5.0  
5.0  
4.9  
5.1  
5.1  
5.1  
5.1  
5.0  
5.2  
5.2  
NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.  
Multipliers for determining the performance with other indoor sections.  
NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed  
temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.  
Air Handler  
AHX60  
Coil  
T.C.  
1.00  
1.00  
S.C.  
0.99  
1.01  
KW  
1.04  
1.04  
Variable Speed  
Furnace  
Coil  
T.C.  
S.C.  
KW  
T*(8,L)X*C16  
T*(8,L)X*C20  
T*9X*C16  
FC/MC62D  
FC/MC62D  
FC/MC62D  
FC/MC62D  
FC/MC62D  
FC/MC62D  
FC/MC62D  
FC/MC62D  
FC/MC62D  
FC/MC62D  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
0.99  
0.99  
0.99  
1.01  
1.01  
1.00  
1.01  
1.00  
1.00  
1.00  
1.00  
0.99  
0.99  
1.08  
1.08  
1.08  
1.08  
1.08  
1.08  
1.08  
1.07  
1.07  
1.07  
MV20D  
FC/MC62D  
T*9X*C20  
T*9X*D20  
Y*(8,L)(C,V)*C16  
Y*(8,L)(C,V)*C20  
Y*9(C,V)*C16  
Y*9(C,V)*C20  
Y*9(C,V)*D20  
Johnson Controls Unitary Products  
17  
510667-YTG-A-0409  
COOLING PERFORMANCE DATA - LOW CFM 1-STAGE OPERATION  
CONDENSING UNIT MODEL NO. YHJF60S41S1  
INDOOR COIL MODEL NO.  
AHX60  
IDCFM  
965  
75  
1165  
75  
1365  
75  
CONDENSING  
ENTERING AIR  
TEMPERATURE  
ID DB (°F)  
ID WB (°F)  
T.C.  
80  
57  
80  
62  
80  
67  
80  
72  
80  
57  
80  
62  
80  
67  
80  
72  
80  
57  
80  
62  
80  
67  
80  
72  
62  
62  
62  
37.3 41.8 41.6 45.5 50.9 40.4 43.7 43.3 47.7 52.2 43.5 45.6 45.1 49.9 53.6  
35.2 32.0 27.8 27.8 23.7 38.1 35.1 30.0 30.0 24.9 41.1 38.2 32.2 32.3 26.1  
65  
75  
S.C.  
KW  
2.1  
2.1  
2.1  
2.1  
2.1  
2.2  
2.2  
2.2  
2.2  
2.2  
2.3  
2.3  
2.3  
2.3  
2.3  
T.C.  
36.2 39.9 39.8 43.6 48.4 39.0 41.6 41.3 45.5 49.8 41.8 43.3 42.8 47.4 51.2  
34.2 31.2 27.0 27.0 22.7 36.8 34.3 29.1 29.1 23.9 39.5 37.3 31.3 31.3 25.1  
S.C.  
KW  
2.4  
2.4  
2.4  
2.4  
2.4  
2.5  
2.5  
2.5  
2.5  
2.5  
2.6  
2.6  
2.6  
2.6  
2.6  
T.C.  
35.2 38.0 37.9 41.8 46.0 37.6 39.4 39.2 43.3 47.4 40.1 40.9 40.5 44.8 48.8  
33.2 30.5 26.1 26.1 21.7 35.5 33.5 28.3 28.3 22.9 37.8 36.5 30.4 30.4 24.0  
85  
S.C.  
KW  
2.7  
2.7  
2.8  
2.7  
2.8  
2.8  
2.8  
2.8  
2.8  
2.8  
2.9  
2.9  
2.9  
2.9  
2.9  
T.C.  
34.1 36.0 36.0 39.9 43.6 36.2 37.3 37.1 41.1 45.0 38.3 38.5 38.2 42.3 46.5  
32.2 29.7 25.3 25.3 20.7 34.2 32.7 27.4 27.4 21.9 36.2 35.7 29.5 29.4 23.0  
95  
S.C.  
KW  
3.1  
3.1  
3.1  
3.1  
3.1  
3.1  
3.1  
3.1  
3.1  
3.1  
3.2  
3.2  
3.2  
3.2  
3.2  
T.C.  
32.4 33.7 33.7 37.3 40.9 34.2 34.7 34.6 38.3 42.1 36.1 35.7 35.5 39.3 43.3  
30.6 28.8 24.3 24.3 19.6 32.3 31.1 26.4 26.3 20.8 34.1 33.3 28.5 28.4 22.0  
105  
115  
125  
S.C.  
KW  
3.5  
3.5  
3.5  
3.5  
3.5  
3.5  
3.5  
3.5  
3.5  
3.5  
3.6  
3.6  
3.6  
3.6  
3.6  
T.C.  
30.6 31.4 31.4 34.7 38.3 32.3 32.1 32.1 35.5 39.2 33.9 32.8 32.8 36.3 40.1  
28.9 27.8 23.3 23.2 18.6 30.5 29.4 25.4 25.3 19.7 32.0 31.0 27.4 27.3 20.9  
S.C.  
KW  
3.9  
3.9  
3.9  
3.9  
3.9  
3.9  
3.9  
3.9  
3.9  
3.9  
4.0  
4.0  
4.0  
4.0  
4.0  
T.C.  
28.9 29.1 29.1 32.1 35.7 30.3 29.5 29.6 32.7 36.3 31.7 29.9 30.1 33.4 37.0  
27.3 26.9 22.4 22.2 17.5 28.6 27.8 24.4 24.2 18.7 30.0 28.6 26.4 26.3 19.9  
S.C.  
KW  
4.3  
4.3  
4.3  
4.3  
4.3  
4.3  
4.3  
4.3  
4.3  
4.4  
4.4  
4.4  
4.4  
4.4  
4.4  
NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.  
Multipliers for determining the performance with other indoor sections.  
NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed  
temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.  
LOW CFM  
Air Handler  
Coil  
T.C.  
S.C.  
KW  
Variable Speed  
Furnace  
Coil  
T.C.  
S.C.  
KW  
MV20D  
FC/MC62D  
1.00  
1.00  
0.99  
T*(8,L)X*C20  
T*9X*C20  
FC/MC62D  
FC/MC62D  
FC/MC62D  
FC/MC62D  
FC/MC62D  
FC/MC62D  
0.92  
1.01  
1.02  
0.97  
0.97  
0.98  
0.87  
1.02  
1.03  
0.94  
0.95  
0.96  
0.97  
1.02  
1.01  
0.99  
1.00  
1.01  
T*9X*D20  
Y*(8,L)(C,V)*C20  
Y*9(C,V)*C20  
Y*9(C,V)*D20  
18  
Johnson Controls Unitary Products  
510667-YTG-A-0409  
COOLING PERFORMANCE DATA - HIGH CFM 2-STAGE OPERATION  
CONDENSING UNIT MODEL NO. YHJF60S41S1  
INDOOR COIL MODEL NO.  
AHX60  
IDCFM  
1650  
75  
1850  
75  
2050  
CONDENSING  
ENTERING AIR  
TEMPERATURE  
ID DB (°F)  
ID WB (°F)  
T.C.  
80  
57  
80  
62  
80  
67  
80  
72  
80  
57  
80  
62  
80  
67  
80  
72  
80  
57  
80  
62  
75  
62  
80  
67  
80  
72  
62  
62  
56.5 60.0 59.6 65.6 70.6 58.5 61.2 60.8 66.7 72.5 60.5 62.3 62.0 67.8 74.4  
55.7 50.3 42.9 42.5 34.9 57.7 53.1 44.9 44.5 36.0 59.6 55.9 47.0 46.5 37.1  
65  
75  
S.C.  
KW  
3.4  
3.5  
3.5  
3.5  
3.6  
3.5  
3.6  
3.5  
3.6  
3.7  
3.6  
3.6  
3.6  
3.7  
3.8  
T.C.  
54.4 57.2 56.8 62.6 67.6 56.3 58.2 57.9 63.6 69.1 58.1 59.2 59.0 64.6 70.6  
53.6 49.1 41.6 41.3 33.5 55.4 51.9 43.7 43.2 34.6 57.3 54.7 45.7 45.2 35.7  
S.C.  
KW  
3.8  
3.9  
3.8  
3.9  
4.0  
3.9  
3.9  
3.9  
4.0  
4.1  
4.0  
4.0  
4.0  
4.1  
4.2  
T.C.  
52.3 54.4 54.0 59.6 64.6 54.0 55.2 55.0 60.5 65.8 55.7 56.1 56.0 61.3 66.9  
51.5 48.0 40.3 40.1 32.2 53.2 50.7 42.4 42.0 33.2 54.9 53.4 44.4 43.9 34.3  
85  
S.C.  
KW  
4.2  
4.2  
4.2  
4.3  
4.4  
4.3  
4.3  
4.3  
4.4  
4.5  
4.4  
4.4  
4.4  
4.5  
4.6  
T.C.  
50.2 51.6 51.2 56.5 61.7 51.8 52.3 52.1 57.3 62.4 53.3 52.9 53.0 58.1 63.2  
49.5 46.8 39.1 38.9 30.8 51.0 49.5 41.1 40.8 31.8 52.5 52.1 43.1 42.6 32.9  
95  
S.C.  
KW  
4.6  
4.6  
4.6  
4.7  
4.8  
4.7  
4.7  
4.7  
4.8  
4.9  
4.8  
4.8  
4.8  
4.9  
5.0  
T.C.  
47.5 48.0 47.8 52.6 57.5 48.8 49.0 48.4 53.3 58.1 50.2 50.0 49.1 54.0 58.8  
46.8 45.2 37.6 37.4 29.2 48.1 47.3 39.6 39.2 30.2 49.5 49.3 41.5 41.1 31.3  
105  
115  
125  
S.C.  
KW  
5.1  
5.1  
5.1  
5.2  
5.3  
5.2  
5.2  
5.2  
5.3  
5.4  
5.3  
5.3  
5.3  
5.4  
5.5  
T.C.  
44.7 44.4 44.4 48.7 53.3 45.9 45.7 44.8 49.3 53.9 47.1 47.1 45.2 49.8 54.4  
44.1 43.7 36.1 35.8 27.6 45.2 45.0 38.0 37.7 28.6 46.4 46.4 39.9 39.5 29.7  
S.C.  
KW  
5.6  
5.6  
5.6  
5.7  
5.8  
5.7  
5.7  
5.7  
5.8  
5.9  
5.8  
5.8  
5.8  
5.9  
6.0  
T.C.  
42.0 40.7 41.0 44.8 49.2 43.0 42.5 41.1 45.3 49.6 44.0 44.2 41.3 45.7 50.0  
41.4 40.7 34.6 34.3 26.0 42.3 42.5 36.5 36.2 27.0 43.3 43.5 38.4 38.0 28.1  
S.C.  
KW  
6.1  
6.1  
6.1  
6.2  
6.3  
6.2  
6.2  
6.2  
6.3  
6.4  
6.3  
6.3  
6.3  
6.4  
6.5  
NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.  
Multipliers for determining the performance with other indoor sections.  
NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed  
temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.  
HIGH CFM  
Air Handler  
Coil  
T.C.  
S.C.  
KW  
Variable Speed  
Furnace  
Coil  
T.C.  
S.C.  
KW  
MV20D  
FC/MC62D  
1.03  
1.01  
0.96  
T*(8,L)X*C20  
T*9X*C20  
FC/MC62D  
FC/MC62D  
FC/MC62D  
FC/MC62D  
FC/MC62D  
FC/MC62D  
1.02  
1.01  
1.02  
1.01  
1.01  
1.01  
0.97  
0.95  
0.97  
0.96  
0.96  
0.96  
0.93  
0.93  
0.93  
0.93  
0.96  
0.95  
T*9X*D20  
Y*(8,L)(C,V)*C20  
Y*9(C,V)*C20  
Y*9(C,V)*D20  
Johnson Controls Unitary Products  
19  
510667-YTG-A-0409  
HEATING PERFORMANCE DATA  
CONDENSING UNIT MODEL NO  
EVAPORATOR COIL MODEL NO  
YHJF18S41S1  
AHX30  
ID CFM  
600  
KW  
4.5  
4.0  
3.5  
4.0  
3.5  
3.1  
3.6  
3.2  
2.9  
3.2  
2.9  
2.5  
2.6  
2.3  
2.0  
2.3  
2.0  
1.8  
AIR TEMP.  
ENTERING  
OUTDOOR UNIT  
AIR TEMP.  
ENTERING  
INDOOR COIL  
450  
750  
KW  
4.9  
4.3  
3.9  
4.2  
3.7  
3.3  
3.8  
3.4  
3.1  
3.4  
3.0  
2.6  
2.7  
2.4  
2.1  
2.3  
2.1  
1.9  
MBTUH  
21.1  
20.5  
19.9  
18.6  
17.7  
16.8  
16.7  
16.1  
15.6  
14.6  
14.2  
13.7  
11.7  
11.2  
10.8  
10.1  
9.6  
KW  
4.1  
3.6  
3.2  
3.8  
3.3  
2.8  
3.4  
3.0  
2.7  
3.1  
2.7  
2.4  
2.6  
2.2  
2.0  
2.3  
1.9  
1.7  
C.O.P.  
1.3  
1.5  
1.6  
1.3  
1.4  
1.6  
1.3  
1.4  
1.5  
1.2  
1.4  
1.5  
1.2  
1.3  
1.5  
1.1  
1.3  
1.4  
MBTUH  
22.2  
21.6  
20.9  
19.2  
18.4  
17.6  
17.3  
16.8  
16.3  
15.1  
14.6  
14.1  
12.0  
11.6  
11.1  
10.3  
9.9  
C.O.P.  
1.2  
1.4  
1.5  
1.2  
1.3  
1.5  
1.2  
1.3  
1.4  
1.2  
1.3  
1.4  
1.1  
1.2  
1.4  
1.1  
1.2  
1.4  
MBTUH  
23.3  
22.6  
21.9  
19.8  
19.1  
18.4  
17.9  
17.4  
17.0  
15.5  
15.0  
14.4  
12.3  
11.9  
11.5  
10.4  
10.2  
9.9  
C.O.P.  
1.1  
1.3  
1.4  
1.1  
1.2  
1.4  
1.1  
1.2  
1.3  
1.1  
1.2  
1.3  
1.1  
1.2  
1.3  
1.0  
1.2  
1.3  
60  
70  
80  
60  
70  
80  
60  
70  
80  
60  
70  
80  
60  
70  
80  
60  
70  
80  
60  
47  
40  
30  
17  
10  
9.1  
9.5  
NOTE: ALL CAPACITIES ARE NET (KBTUH) WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.  
Multipliers for determining the performance with other indoor sections.  
Air Handler  
AV*36  
Coil  
MBH  
1.00  
1.00  
1.00  
KW  
1.03  
0.97  
1.01  
COP  
0.97  
1.03  
0.99  
Variable Speed  
Furnace  
Coil  
MBH  
KW  
COP  
T*(8,L)X*A12  
FC/MC/PC32A  
FC/MC/PC32A  
FC/MC/PC35B  
FC/MC/PC35C  
FC/MC/PC35B  
FC/MC/PC35C  
FC/MC/PC37A  
FC/MC/PC43B  
0.99  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
0.99  
0.97  
0.99  
0.98  
0.98  
0.99  
1.01  
0.98  
1.00  
1.03  
1.01  
1.02  
1.02  
1.01  
0.99  
1.02  
MV12B  
FC/MC35B  
FC/MC43B  
Y*(8,L)(C,V)*A12  
Y*(8,L)(C,V)*B12  
Y*(8,L)(C,V)*C16  
Y*9(C,V)*B12  
MV12B  
Y*9(C,V)*C16  
Y*(8,L)(C,V)*A12  
Y*(8,L)(C,V)*B12  
20  
Johnson Controls Unitary Products  
510667-YTG-A-0409  
HEATING PERFORMANCE DATA  
CONDENSING UNIT MODEL NO  
EVAPORATOR COIL MODEL NO  
YHJF24S41S1  
AHX30  
ID CFM  
800  
KW  
4.3  
3.7  
3.2  
4.0  
3.4  
2.9  
3.5  
3.0  
2.6  
3.1  
2.7  
2.4  
2.7  
2.2  
1.7  
2.4  
2.0  
1.7  
AIR TEMP.  
ENTERING  
OUTDOOR UNIT  
AIR TEMP.  
ENTERING  
INDOOR COIL  
600  
1000  
MBTUH  
26.8  
25.1  
23.3  
24.8  
22.7  
20.7  
20.8  
19.5  
18.2  
18.7  
17.5  
16.2  
15.5  
13.1  
10.8  
13.5  
12.2  
10.8  
KW  
4.0  
3.4  
2.9  
3.8  
3.2  
2.7  
3.3  
2.9  
2.4  
3.1  
2.6  
2.3  
2.7  
2.1  
1.6  
2.4  
1.9  
1.6  
C.O.P.  
1.7  
1.9  
2.1  
1.7  
1.8  
2.0  
1.6  
1.8  
2.0  
1.6  
1.7  
1.9  
1.5  
1.6  
1.8  
1.5  
1.6  
1.8  
MBTUH  
27.6  
26.1  
24.7  
25.0  
23.2  
21.5  
21.5  
20.3  
19.1  
18.8  
17.8  
16.8  
15.8  
13.8  
11.8  
13.8  
12.5  
11.2  
C.O.P.  
1.6  
1.8  
2.0  
1.5  
1.7  
1.9  
1.5  
1.7  
1.8  
1.5  
1.6  
1.8  
1.4  
1.6  
1.7  
1.4  
1.5  
1.7  
MBTUH  
28.4  
27.2  
26.1  
25.2  
23.7  
22.2  
22.3  
21.2  
20.0  
18.9  
18.1  
17.3  
16.2  
14.5  
12.8  
14.0  
12.8  
11.6  
KW  
4.5  
4.0  
3.5  
4.1  
3.6  
3.1  
3.7  
3.2  
2.8  
3.2  
2.8  
2.5  
2.8  
2.3  
1.9  
2.4  
2.0  
1.7  
C.O.P.  
1.5  
1.6  
1.8  
1.4  
1.6  
1.8  
1.4  
1.6  
1.7  
1.4  
1.5  
1.7  
1.4  
1.5  
1.6  
1.3  
1.5  
1.6  
60  
70  
80  
60  
70  
80  
60  
70  
80  
60  
70  
80  
60  
70  
80  
60  
70  
80  
60  
47  
40  
30  
17  
10  
NOTE: ALL CAPACITIES ARE NET (KBTUH) WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.  
Multipliers for determining the performance with other indoor sections.  
Variable Speed  
Air Handler  
AHX36  
Coil  
MBH  
1.01  
0.99  
1.00  
1.00  
1.00  
1.00  
KW  
1.02  
1.02  
1.00  
1.01  
1.01  
1.05  
COP  
0.99  
0.97  
1.00  
0.99  
0.99  
0.95  
Coil  
MBH  
KW  
COP  
Furnace  
T*(8,L)X*C16  
T*9X*B12  
FC/MC/PC43C  
FC/MC/PC43B  
FC/MC/PC43C  
FC/MC/PC43C  
FC/MC/PC32A  
FC/MC/PC35B  
FC/MC/PC35C  
FC/MC/PC35C  
FC/MC/PC35B  
FC/MC/PC35C  
FC/MC/PC35C  
FC/MC/PC37A  
FC/MC/PC43B  
FC/MC/PC43C  
FC/MC/PC43C  
FC/MC/PC43B  
FC/MC/PC43C  
FC/MC/PC43C  
0.99  
1.00  
0.99  
0.99  
1.00  
0.99  
1.00  
0.98  
1.00  
1.00  
0.99  
1.01  
0.99  
1.00  
0.99  
1.00  
1.00  
1.01  
1.07  
1.07  
1.04  
1.03  
0.99  
0.98  
1.01  
0.99  
1.00  
1.02  
0.98  
1.03  
1.01  
1.05  
1.02  
1.04  
1.05  
1.05  
0.93  
0.94  
0.95  
0.96  
1.01  
1.01  
0.99  
0.99  
1.00  
0.98  
1.01  
0.98  
0.98  
0.95  
0.97  
0.96  
0.95  
0.96  
AV*36  
F6FP030  
F6FP036  
MV12B  
T*9X*C16  
T*9X*C20  
FC/MC35B  
FC/MC43B  
Y*(8,L)(C,V)*A12  
Y*(8,L)(C,V)*B12  
Y*(8,L)(C,V)*C16  
Y*(8,L)(C,V)*C20  
Y*9(C,V)*B12  
Y*9(C,V)*C16  
Y*9(C,V)*C20  
Y*(8,L)(C,V)*A12  
Y*(8,L)(C,V)*B12  
Y*(8,L)(C,V)*C16  
Y*(8,L)(C,V)*C20  
Y*9(C,V)*B12  
Y*9(C,V)*C16  
Y*9(C,V)*C20  
MV12B  
Variable Speed  
Furnace  
Coil  
MBH  
KW  
COP  
T*(8,L)X*A12  
T*(8,L)X*B12  
T*(8,L)X*C16  
T*(8,L)X*C20  
T*9X*B12  
FC/MC/PC32A  
FC/MC/PC35B  
FC/MC/PC35C  
FC/MC/PC35C  
FC/MC/PC35B  
FC/MC/PC35C  
FC/MC/PC35C  
FC/MC/PC37A  
FC/MC/PC43B  
0.99  
0.99  
0.99  
0.99  
0.99  
0.99  
1.00  
1.00  
0.99  
1.02  
1.03  
1.03  
1.03  
1.02  
1.04  
1.02  
1.07  
1.07  
0.97  
0.96  
0.96  
0.96  
0.97  
0.95  
0.98  
0.94  
0.93  
T*9X*C16  
T*9X*C20  
T*(8,L)X*A12  
T*(8,L)X*B12  
Johnson Controls Unitary Products  
21  
510667-YTG-A-0409  
HEATING PERFORMANCE DATA  
CONDENSING UNIT MODEL NO  
EVAPORATOR COIL MODEL NO  
YHJF30S41S1  
AHX36  
ID CFM  
1000  
KW  
4.8  
AIR TEMP.  
ENTERING  
OUTDOOR UNIT  
AIR TEMP.  
ENTERING  
INDOOR COIL  
800  
1200  
KW  
5.0  
4.4  
4.0  
4.4  
3.9  
3.5  
4.0  
3.6  
3.2  
3.5  
3.1  
2.7  
2.9  
2.5  
2.2  
2.5  
2.1  
1.9  
MBTUH  
36.9  
35.9  
34.8  
31.3  
30.5  
29.8  
28.4  
27.6  
26.8  
24.8  
23.9  
23.0  
19.9  
18.8  
17.8  
17.1  
15.8  
14.4  
KW  
4.6  
4.0  
3.5  
4.1  
3.6  
3.1  
3.7  
3.3  
2.9  
3.3  
2.9  
2.6  
2.8  
2.4  
2.0  
2.4  
2.0  
1.7  
C.O.P.  
2.1  
2.3  
2.6  
2.0  
2.2  
2.5  
1.9  
2.2  
2.4  
1.9  
2.1  
2.3  
1.8  
2.0  
2.3  
1.8  
2.0  
2.2  
MBTUH  
37.4  
36.5  
35.5  
31.8  
31.0  
30.2  
28.9  
28.1  
27.4  
25.1  
24.3  
23.4  
20.1  
19.2  
18.3  
17.4  
16.3  
15.1  
C.O.P.  
1.9  
2.2  
2.4  
1.8  
2.1  
2.3  
1.8  
2.0  
2.3  
1.8  
2.0  
2.2  
1.7  
2.0  
2.2  
1.7  
1.9  
2.1  
MBTUH  
38.0  
37.1  
36.2  
32.3  
31.5  
30.7  
29.3  
28.6  
27.9  
25.4  
24.6  
23.8  
20.4  
19.6  
18.8  
17.6  
16.7  
15.8  
C.O.P.  
1.8  
2.0  
2.2  
1.7  
1.9  
2.2  
1.7  
1.9  
2.1  
1.7  
1.9  
2.1  
1.7  
1.9  
2.1  
1.6  
1.8  
2.0  
60  
70  
80  
60  
70  
80  
60  
70  
80  
60  
70  
80  
60  
70  
80  
60  
70  
80  
60  
47  
40  
30  
17  
10  
4.2  
3.8  
4.2  
3.7  
3.3  
3.9  
3.4  
3.0  
3.4  
3.0  
2.7  
2.8  
2.4  
2.1  
2.4  
2.1  
1.8  
NOTE: ALL CAPACITIES ARE NET (KBTUH) WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.  
Multipliers for determining the performance with other indoor sections.  
Air Handler  
AV*36  
Coil  
MBH  
0.99  
0.99  
1.00  
1.00  
KW  
1.00  
1.00  
0.97  
0.98  
COP  
1.00  
1.00  
1.03  
1.02  
Variable Speed  
Furnace  
Coil  
MBH  
KW  
COP  
T*(8,L)X*A12  
T*(8,L)X*B12  
T*(8,L)X*C16  
T*9X*B12  
FC/MC/PC37A  
FC/MC/PC43B  
FC/MC/PC43C  
FC/MC/PC43B  
FC/MC/PC43C  
FC/MC/PC37A  
FC/MC/PC43B  
FC/MC/PC43C  
FC/MC/PC43C  
FC/MC/PC43B  
FC/MC/PC43C  
FC/MC/PC43C  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.01  
1.00  
0.99  
1.00  
0.99  
0.95  
0.97  
0.98  
0.99  
0.96  
0.98  
0.98  
1.00  
1.00  
1.01  
1.01  
1.01  
1.05  
1.04  
1.02  
1.02  
1.04  
1.03  
1.03  
F6FP042  
MV12B  
FC/MC43B  
FC/MC43C  
MV16C  
T*9X*C16  
Y*(8,L)(C,V)*A12  
Y*(8,L)(C,V)*B12  
Y*(8,L)(C,V)*C16  
Y*(8,L)(C,V)*C20  
Y*9(C,V)*B12  
Y*9(C,V)*C16  
Y*9(C,V)*C20  
22  
Johnson Controls Unitary Products  
510667-YTG-A-0409  
HEATING PERFORMANCE DATA  
CONDENSING UNIT MODEL NO  
EVAPORATOR COIL MODEL NO  
YHJF36S41S1  
AHX36  
ID CFM  
1200  
KW  
4.4  
AIR TEMP.  
ENTERING  
OUTDOOR UNIT  
AIR TEMP.  
ENTERING  
INDOOR COIL  
1000  
KW  
1400  
MBTUH  
47.2  
46.3  
45.3  
40.0  
39.5  
38.9  
36.8  
36.3  
35.7  
31.9  
31.5  
31.0  
25.3  
24.2  
23.1  
21.6  
21.4  
21.1  
C.O.P.  
2.9  
3.3  
3.7  
2.8  
3.2  
3.5  
2.7  
3.1  
3.5  
2.7  
3.1  
3.4  
2.5  
2.9  
3.2  
2.3  
2.7  
3.1  
MBTUH  
47.9  
46.8  
45.6  
40.4  
39.8  
39.2  
37.0  
36.4  
35.9  
32.0  
31.6  
31.2  
25.4  
24.7  
24.1  
20.9  
20.3  
19.6  
C.O.P.  
2.7  
3.1  
3.4  
2.7  
3.0  
3.3  
2.6  
2.9  
3.3  
2.5  
2.9  
3.2  
2.4  
2.8  
3.1  
2.3  
2.6  
2.9  
MBTUH  
48.6  
47.3  
46.0  
40.9  
40.1  
39.4  
37.2  
36.6  
36.0  
32.1  
31.7  
31.4  
25.4  
25.2  
25.0  
20.2  
19.2  
18.2  
KW  
4.6  
4.1  
3.6  
4.0  
3.5  
3.2  
3.7  
3.3  
2.9  
3.2  
2.9  
2.6  
2.6  
2.3  
2.1  
2.2  
1.9  
1.6  
C.O.P.  
2.6  
2.9  
3.2  
2.5  
2.8  
3.2  
2.5  
2.8  
3.1  
2.4  
2.7  
3.1  
2.3  
2.6  
3.0  
2.2  
2.5  
2.7  
60  
70  
80  
60  
70  
80  
60  
70  
80  
60  
70  
80  
60  
70  
80  
60  
70  
80  
4.2  
3.7  
3.3  
3.7  
3.3  
2.9  
3.5  
3.1  
2.7  
3.1  
2.7  
2.4  
2.6  
2.2  
1.9  
2.3  
2.0  
1.8  
60  
47  
40  
30  
17  
10  
3.9  
3.4  
3.8  
3.4  
3.0  
3.6  
3.2  
2.8  
3.1  
2.8  
2.5  
2.6  
2.3  
2.0  
2.3  
2.0  
1.7  
NOTE: ALL CAPACITIES ARE NET (KBTUH) WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.  
Multipliers for determining the performance with other indoor sections.  
Air Handler  
AHX42  
Coil  
MBH  
1.00  
1.00  
1.00  
1.00  
1.00  
KW  
1.01  
0.99  
1.02  
0.98  
0.98  
COP  
0.99  
1.01  
0.98  
1.02  
1.02  
Variable Speed  
Furnace  
Coil  
MBH  
KW  
COP  
T*(8,L)X*A12  
T*(8,L)X*B12  
T*(8,L)X*C16  
T*(8,L)X*C20  
T*9X*B12  
FC/MC/PC37A  
FC/MC/PC43B  
FC/MC/PC43C  
FC/MC/PC43C  
FC/MC/PC43B  
FC/MC/PC43C  
FC/MC/PC43C  
FC/MC/PC43C  
FC/MC/PC43C  
FC/MC/PC43C  
FC/MC/PC43C  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
0.99  
1.02  
1.00  
1.01  
0.98  
0.98  
0.98  
0.99  
0.97  
1.00  
1.00  
1.01  
0.98  
1.00  
0.99  
1.02  
1.02  
1.02  
1.01  
1.03  
AV*36  
F6FP042  
MV12B  
FC/MC43B  
FC/MC43C  
MV16C  
T*9X*C16  
T*9X*C20  
Y*(8,L)(C,V)*C16  
Y*(8,L)(C,V)*C20  
Y*9(C,V)*C16  
Y*9(C,V)*C20  
Johnson Controls Unitary Products  
23  
510667-YTG-A-0409  
HEATING PERFORMANCE DATA  
CONDENSING UNIT MODEL NO  
EVAPORATOR COIL MODEL NO  
YHJF42S41S1  
AHX60  
ID CFM  
1400  
KW  
4.1  
AIR TEMP.  
ENTERING  
OUTDOOR UNIT  
AIR TEMP.  
ENTERING  
INDOOR COIL  
1200  
KW  
1600  
KW  
4.2  
3.9  
3.6  
4.1  
3.7  
3.4  
3.9  
3.5  
3.2  
3.4  
3.1  
2.8  
2.8  
2.5  
2.3  
2.5  
2.3  
2.1  
MBTUH  
45.3  
45.1  
44.9  
41.3  
40.7  
40.0  
38.2  
37.4  
36.6  
33.3  
32.7  
32.0  
26.7  
25.2  
23.6  
22.8  
22.9  
22.9  
C.O.P.  
2.8  
3.0  
3.3  
2.5  
2.8  
3.1  
2.5  
2.8  
3.0  
2.4  
2.7  
3.0  
2.2  
2.5  
2.8  
2.3  
2.6  
2.8  
MBTUH  
45.0  
44.9  
44.8  
41.2  
40.7  
40.2  
38.4  
37.7  
37.1  
33.4  
32.8  
32.2  
26.9  
20.9  
14.9  
23.3  
23.2  
23.1  
C.O.P.  
2.7  
2.9  
3.1  
2.5  
2.7  
3.0  
2.4  
2.7  
3.0  
2.4  
2.6  
2.9  
2.2  
2.4  
2.7  
2.2  
2.5  
2.8  
MBTUH  
44.6  
44.6  
44.7  
41.1  
40.7  
40.3  
38.5  
38.1  
37.7  
33.5  
32.9  
32.3  
27.2  
26.7  
26.3  
23.8  
23.6  
23.3  
C.O.P.  
2.6  
2.8  
3.0  
2.4  
2.6  
2.9  
2.3  
2.6  
2.9  
2.3  
2.5  
2.8  
2.2  
2.5  
2.7  
2.2  
2.4  
2.7  
60  
70  
80  
60  
70  
80  
60  
70  
80  
60  
70  
80  
60  
70  
80  
60  
70  
80  
4.1  
3.8  
3.5  
4.1  
3.6  
3.3  
3.8  
3.4  
3.1  
3.4  
3.0  
2.7  
2.9  
2.5  
2.1  
2.5  
2.2  
2.1  
60  
47  
40  
30  
17  
10  
3.8  
3.6  
4.1  
3.7  
3.3  
3.9  
3.5  
3.1  
3.4  
3.1  
2.8  
2.9  
2.5  
2.2  
2.5  
2.3  
2.1  
NOTE: ALL CAPACITIES ARE NET (KBTUH) WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.  
Multipliers for determining the performance with other indoor sections.  
Air Handler  
F6FP060  
MV20D  
Coil  
MBH  
1.01  
1.00  
KW  
1.01  
1.01  
COP  
1.00  
1.00  
Variable Speed  
Furnace  
Coil  
MBH  
KW  
COP  
T*(8,L)X*C16  
T*(8,L)X*C20  
T*9X*C16  
FC/MC62D  
FC/MC62D  
FC/MC62D  
FC/MC62D  
FC/MC62D  
FC/MC62D  
FC/MC62D  
FC/MC62D  
FC/MC62D  
1.00  
1.01  
1.01  
1.00  
1.00  
1.01  
1.02  
1.01  
1.01  
1.02  
1.02  
1.00  
1.01  
1.01  
1.00  
0.97  
0.98  
0.99  
0.99  
0.99  
1.02  
1.00  
1.00  
1.01  
1.06  
1.04  
1.03  
FC/MC62D  
T*9X*C20  
T*9X*D20  
Y*(8,L)(C,V)*C20  
Y*9(C,V)*C16  
Y*9(C,V)*C20  
Y*9(C,V)*D20  
24  
Johnson Controls Unitary Products  
510667-YTG-A-0409  
HEATING PERFORMANCE DATA  
CONDENSING UNIT MODEL NO  
EVAPORATOR COIL MODEL NO  
YHJF48S41S1  
F6FP060  
ID CFM  
1600  
KW  
4.5  
AIR TEMP.  
ENTERING  
OUTDOOR UNIT  
AIR TEMP.  
ENTERING  
INDOOR COIL  
1400  
KW  
1800  
MBTUH  
62.2  
60.9  
59.5  
53.1  
52.0  
50.9  
47.9  
47.2  
46.5  
40.1  
38.9  
37.8  
30.2  
28.7  
27.3  
25.2  
24.5  
23.8  
C.O.P.  
3.7  
4.2  
4.8  
3.8  
4.3  
4.8  
3.8  
4.4  
5.0  
3.6  
3.8  
4.0  
2.8  
3.0  
3.2  
2.6  
2.9  
3.1  
MBTUH  
62.7  
61.2  
59.8  
53.1  
52.0  
51.0  
47.8  
47.0  
46.2  
40.2  
39.3  
38.3  
31.3  
29.5  
27.7  
24.8  
25.3  
25.7  
C.O.P.  
3.5  
4.0  
4.5  
3.6  
4.1  
4.6  
3.6  
4.2  
4.7  
3.5  
3.8  
4.0  
2.8  
3.0  
3.2  
2.5  
3.0  
3.5  
MBTUH  
63.2  
61.6  
60.0  
53.1  
52.1  
51.0  
47.8  
46.9  
45.9  
40.3  
39.6  
38.8  
32.4  
30.3  
28.1  
24.4  
26.1  
27.7  
KW  
4.6  
4.1  
3.6  
3.8  
3.3  
2.9  
3.4  
3.0  
2.6  
2.9  
2.6  
2.4  
2.9  
2.5  
2.2  
2.3  
2.0  
1.8  
C.O.P.  
3.3  
3.8  
4.2  
3.4  
3.9  
4.5  
3.4  
3.9  
4.4  
3.3  
3.7  
4.1  
2.7  
2.9  
3.1  
2.5  
3.2  
3.9  
60  
70  
80  
60  
70  
80  
60  
70  
80  
60  
70  
80  
60  
70  
80  
60  
70  
80  
4.3  
3.8  
3.3  
3.6  
3.2  
2.8  
3.2  
2.8  
2.5  
2.9  
2.7  
2.5  
2.6  
2.4  
2.2  
2.4  
2.1  
1.9  
60  
47  
40  
30  
17  
10  
3.9  
3.5  
3.7  
3.2  
2.9  
3.3  
2.9  
2.6  
2.9  
2.7  
2.4  
2.8  
2.4  
2.2  
2.3  
2.1  
1.8  
NOTE: ALL CAPACITIES ARE NET (KBTUH) WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.  
Multipliers for determining the performance with other indoor sections.  
Air Handler  
AHX60  
Coil  
MBH  
1.00  
1.00  
KW  
0.99  
0.99  
COP  
1.01  
1.01  
Variable Speed  
Furnace  
Coil  
MBH  
KW  
COP  
T*(8,L)X*C16  
T*(8,L)X*C20  
T*9X*C16  
FC/MC62D  
FC/MC62D  
FC/MC62D  
FC/MC62D  
FC/MC62D  
FC/MC62D  
FC/MC62D  
FC/MC62D  
FC/MC62D  
FC/MC62D  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
0.98  
0.99  
0.98  
0.99  
0.98  
0.98  
0.98  
0.97  
0.96  
0.97  
1.02  
1.01  
1.02  
1.01  
1.02  
1.02  
1.02  
1.03  
1.04  
1.03  
MV20D  
FC/MC62D  
T*9X*C20  
T*9X*D20  
Y*(8,L)(C,V)*C16  
Y*(8,L)(C,V)*C20  
Y*9(C,V)*C16  
Y*9(C,V)*C20  
Y*9(C,V)*D20  
Johnson Controls Unitary Products  
25  
HEATING PERFORMANCE DATA  
CONDENSING UNIT MODEL NO  
EVAPORATOR COIL MODEL NO  
YHJF60S41S1  
AHX60  
ID CFM  
1800  
KW  
AIR TEMP.  
ENTERING  
OUTDOOR UNIT  
AIR TEMP.  
ENTERING  
INDOOR COIL  
1600  
KW  
2000  
KW  
MBTUH  
70.70  
69.78  
68.86  
61.77  
60.84  
59.90  
56.20  
55.47  
54.75  
49.33  
47.84  
46.36  
40.18  
40.02  
39.86  
35.02  
33.76  
32.50  
C.O.P.  
4.25  
4.72  
5.19  
4.05  
4.53  
5.01  
3.93  
4.42  
4.90  
3.78  
4.36  
4.94  
3.64  
4.14  
4.65  
3.52  
3.98  
4.44  
MBTUH  
71.76  
70.63  
69.51  
62.15  
61.18  
60.20  
56.47  
55.62  
54.77  
49.52  
47.68  
45.84  
37.45  
38.68  
39.91  
35.29  
34.56  
33.83  
C.O.P.  
4.11  
4.57  
5.03  
3.92  
4.39  
4.86  
3.80  
4.27  
4.75  
3.70  
4.21  
4.71  
3.50  
4.00  
4.53  
3.45  
3.90  
4.34  
MBTUH  
72.83  
71.49  
70.15  
62.54  
61.52  
60.50  
56.74  
55.76  
54.79  
49.72  
47.52  
45.31  
34.72  
37.36  
39.99  
35.54  
35.35  
35.15  
C.O.P.  
3.97  
4.41  
4.86  
3.78  
4.23  
4.69  
3.69  
4.13  
4.57  
3.61  
4.06  
4.51  
3.40  
3.91  
4.42  
3.38  
3.82  
4.26  
60  
70  
80  
60  
70  
80  
60  
70  
80  
60  
70  
80  
60  
70  
80  
60  
70  
80  
4.28  
3.85  
3.48  
3.89  
3.47  
3.13  
3.64  
3.24  
2.92  
3.30  
2.83  
2.45  
2.78  
2.47  
2.23  
2.49  
2.16  
1.89  
4.41  
3.95  
3.58  
3.97  
3.55  
3.19  
3.70  
3.30  
2.96  
3.33  
2.87  
2.49  
2.80  
2.60  
2.25  
2.51  
2.22  
1.97  
4.54  
4.07  
3.67  
4.05  
3.62  
3.27  
3.76  
3.35  
3.02  
3.34  
2.90  
2.53  
2.80  
2.50  
2.27  
2.53  
2.27  
2.06  
60  
47  
40  
30  
17  
10  
NOTE: ALL CAPACITIES ARE NET (KBTUH) WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.  
Multipliers for determining the performance with other indoor sections.  
Air Handler  
Coil  
MBH  
KW  
COP  
Variable Speed  
Furnace  
Coil  
MBH  
KW  
COP  
MV20D  
FC/MC62D  
0.99  
1.00  
0.99  
T*(8,L)X*C20  
T*9X*C20  
FC/MC62D  
FC/MC62D  
FC/MC62D  
FC/MC62D  
FC/MC62D  
FC/MC62D  
0.97  
1.00  
1.00  
0.99  
0.99  
1.00  
0.89  
1.01  
1.02  
0.95  
0.96  
0.97  
1.10  
1.00  
0.99  
1.04  
1.04  
1.03  
T*9X*D20  
Y*(8,L)(C,V)*C20  
Y*9(C,V)*C20  
Y*9(C,V)*D20  
Subject to change without notice. Printed in U.S.A.  
Copyright © 2009 by Johnson Controls, Inc. All rights reserved.  
510667-YTG-A-0409  
Supersedes: Nothing  
Johnson Controls Unitary Products  
5005 York Drive  
Norman, OK 73069  

Nextel Comm Brr L User Manual
Omega Speaker Systems 23991 User Manual
Panasonic Cw C120au User Manual
Panasonic Kx Fp105 User Manual
Sears Air Conditioner Lt103cnr User Manual
Soleus Air Soleusair Sg Ttw 12hc 26 User Manual
Sunpentown Intl Wa 1010e User Manual
Trion Eliminator Se800e User Manual
Troy Bilt Automobile Parts 83 User Manual
Tru Test 1 J User Manual